1. m m Download the BEA DECODER app for a quick overview of settings ATED PP Google play AppStore DESCRIPTION IXI0 DT3 Opening amp safety sensor for automatic sliding doors according to EN 16005 and DIN 18650 including emergency exits User s Guide for product version 0400 and higher See product label for serial number LCD 1 2 radar antenna narrow field 3 radar antenna wide field 4 IR curtain width adjustment 5 IR lenses ACCESSORIES cover main connector main adjustment knob IR curtain angle adjustment knob oe ee BA Bracket accessory A Retrofit interface Door bell interface CA Ceiling accessory RA Rain accessory CDA Curved door accessory i n Smart Daisy Chain hub 9 V battery HOW TO USE THE LCD DISPLAY DURING NORMAL FUNCTIONING La ID ba edb J Fa F rt Ee Pd Fa FE Opening Safety Negative display active output To adjust contrast push and turn impulse the grey button simultaneously During normal function only FACTORY VALUE VS SAVED VALUE AIR Immunity AIR Immunity l 2 5m 2 Pe oti 7 A displayed value factory value i displayed value saved value NAVIGATING IN MENUS Push to enter Password Enter password if gs Select your language before the LCD menu necessary entering the first LCD menu l l Deutsch Not during the first 4 During the first 30 seconds after minute after power on power on of t
2. of the LCD PJ Check wiring EF Decrease the angle of the IR curtains BJ Increase the IR immunity filter values gt 2 8 m EJ Deactivate 1 curtain EN Slightly increase the angle of the IR curtains EX Decrease the IR immunity filter values 1 3 lt 2 8 m Eliminate the cause of disturbance lamps rain cover door controller housing properly grounded EH Replace sensor ET Change radar field angle or antenna EJ Launch a quick setup EJ If orange LED flashes again replace sensor EF Replace sensor KJ Replace sensor Cut and restore power supply If orange LED lights up again replace sensor Move the IR curtains away from the door Install the sensor as close to the door as possible If needed use a bracket accessory Launch a new assisted setup Check if the sensor is fastened firmly EJ Check position of cable and cover EH Launch an assisted setup and adjust the IR angle ET Increase the IR immunity filter to value 3 EJ Select presetting 2 or 3 LT Select presetting 2 or 3 Increase radar immunity filter ET Change radar field angle ET Check if the sensor and door cover is fastened firmly ET Check position of cable and cover Remove the objects if possible A Change radar field size or angle EE Check wiring 1 Check output configuration setting ET Check wiring EF Enter the right password If you forgot the code cut and restore the power supply to access the sensor without e
3. the detection field with a piece of paper and not the Spotfinder which detects the whole emitted field The size of the detection field varies according to the 3 50 m EN 18005 mounting height and the settings of the sensor Mounting Detection DIN 18650 height width BS 7036 3m 3m The full door width must be covered 2 00 m 2 00 m 2 50m 2 50m 2 20 m 2 20 m 2 50 m 2 50 m n A 3 00 m d max 3 50 m d max E d max 2 5 m dmax 3m SETTINGS FS of rai mai Choose one of the following presettings or adjust the sensor manually see p 5 i Presettings Standard Presettinas CRITICAL ENVIRONMENT critical installations due to surroundings or weather Critical env Presettings SHOPPING STREET installations in narrow streets with pedestrian traffic Shopping str FJ setup SETUP 1 QUICK reference picture SETUP 2 ASSISTED test of full door cycle reference picture BASIC ADVANCED DIAGNOSTICS OVERVIEW OF SETTINGS BHH 0 1 2 3 4 Back More PRESETTINGS RAD FIELDSIZE small gt gt gt gt gt gt a gt large NO NC NC NO current freq NO normally open freq frequency output RAD OUTPUT NO NC NO NC NC NC normally closed current current output f lt 2 8 m E t gt 2 8m a EE IR FREQUENCY More Back i aA aes CH factory value Back t f J z z More 2 2 e RAD IMMUNITY low at
4. 1 1996 Chapter 7 3 2 only applicable for relay output in frequency mode and current source output EN 12978 EN ISO 13849 1 2008 PL c CAT 2 under the condition that the door control system monitors the sensor at least once per door cycle IEC 61496 1 2012 ESPE Type 2 EN 16005 2012 Chapter 4 6 8 DIN 18650 1 2010 Chapter 5 7 4 BS 7036 1 1996 Chapter 8 1 Specifications are subject to changes without prior notice All values measured in specific conditions BEA SA LIEGE Science Park ALLEE DES NOISETIERS 5 4031 ANGLEUR BELGIUM T 32 4 361 65 65 F 32 4 361 28 58 INFO BEA BE WWW BEA BE BEA hereby declares that the IXIO DT3 is in conformity with the basic requirements and the other relevant provisions of the directives 1999 5 EC 2006 95 EC and 2006 42 EC Notified Body for EC type inspection 0044 TUV NORD CERT GmbH Langemarckstr 20 D 45141 Essen EC type examination certificate number 44 205 12 405836 001 Angleur October 2014 Pierre Gardier authorized representative and responsible for technical documentation The complete declaration of conformity is available on our website www bea pedestrian be Only for EC countries According to the European Guideline 2012 19 EU for Waste Electrical and Electronic Equipment WEEE
5. gt gt gt gt gt Dp radar uni uni bi uni PRM l RAD DIRECTION a bi umi PRM AWAY auto auto auto GD RAD HOLDTIME 05s is f 2s f 3s f 4s E 5s 6s 7s f 8s f Qs O IR WIDTH A amd f LL taD EAA DA EEDE AAG aE Ip service IR NUMBER ee 2 ci BE o IR PRESENCE TIME motion 155 30s f 1minf 2min Smin 10min a e NO NC NC NO current freq IR OUTPUT NO NC NO NC NC REDIRECTION motion motion opening output is active in case of p mone aT TE presence eae 2 motion and presence detection SMART DAISY CHAIN 1 2 1 sensor in chain of 2 2 2 2 4 sensor in chain of 2 off 1 2 2 2 1 3 2 3 3 3 1 3 1 in chain of 3 2 3 2 4 in chain of 3 3 3 3 in chain of 3 recone et een G reset reset 0 05s 0 10s 0 25s 0 50s 0 755 1s Setting in combination with an accessory see p 1 For more information see user s guide of accessory i all parameter settings in zipped format POWERSUPPLY supply voltage at power connector R see application note on ZIP CODE OPERATINGTIME power duration since first startup unique ID number RESET LOG delete all saved errors ERROR LOG last 10 errors day indication PASSWORD LCD and remotre control password IR SPOTVIEW view of spot s that trigger detection 0000 no password IR C1 ENERG signal amplitude received on curtain 1 LANGUAGE language of LCD menu IR C2 ENERG signal amplitude received on curtain 2 ADMIN enter code to access admin m
6. he sensor or later in of the sensor the diagnostics menu Select More to go to a Select Back to Scroll menu return to previous next level items menu or display resettings basic settings advanced settings diagnostics AIF Immunity Lia Scroll Push ent select to save rameter new value up down Palen CHANGING A ZIP CODE CHH See application note on ZIP CODE ZIP code ZIP coc ZIP coc ZIP cod mS RE24 1 56 KG4 E241 E24 1 H24 1 01 0 800 O2F 01 08 0108 01 0 8 IZIP code ZIP code Validate the last digit in order to activate the new ZIP code v valid ZIP code values will be changed accordingly v X invalid ZIP code no values will be changed mee J v x valid ZIP code but from a different product Only available values will be changed H24 1 56 KG4 01 0 800 020 VALUE CHECK WITH REMOTE CONTROL Pressing a parameter symbol on your remote control D cp 4 gt 2 displays the saved value directly on the LCD screen A Do not unlock first ao IXIO DT3 INSTALLATION GUIDE 1 MOUNTING amp WIRING POWER SUPPLY am A UO Lu OPENING INPUT 4 SAFETY INPUT ad SENSOR a TEST OUTPUT D OPENING INPUT FOR CURRENT SOURCE Output status when sensor is operational Fixation is compatible with the ACTIVS For compliance with EN 16005 and DIN 18650 connection to door controller test output is required Cu
7. ntering a password during 1 minute LED SIGNAL Motion Presence detection detection LED flashes LED flashes LED flashes x times red green INSTALLATION LED flashes quickly e LED is off The sensor should be Do not cover the sensor fixed firmly to avoid extreme vibrations MAINTENANCE It is recommended to clean the optical parts at least once a year or more if required due to environmental conditions SAFETY The door control unit and the door cover profile must be correctly earthed Only trained and qualified personnel may install and setup the sensor Avoid moving objects and light sources in the detection field Always test the good functioning of the installation before leaving the premises Avoid highly reflective objects in the infrared field Do not use aggressive products to clean the optical parts The warranty is invalid i unauthorized repairs are made or attempted by unauthorized personnel BEA Original instructions 42 8302 V1 10 14 A HALMA COMPANY TECHNICAL SPECIFICATIONS Supply voltage 12 V 24 V AC 4 10 12 V 30 V DC 4 10 to be operated from SELV compatible power supplies only Power consumption lt 2 5 W Mounting height Temperature range 2 m to 3 5 m local regulations may have an impact on the acceptable mounting height 25 C to 55 C 0 95 relative humidity non condensing Degree of protecti
8. ode TROUBLESHOOTING m mi N ETI mi ul m 0 mi nN mi Oo KOSS 82 ORANGE LED flashes 1 x ORANGE LED flashes 2 x ORANGE LED flashes 4 x ORANGE LED flashes 5 x ORANGE LED flashes 6 x ORANGE LED flashes 7 x ORANGE LED flashes 8 x ORANGE LED flashes 9 x ORANGE LED is on RED LED flashes quickly after an assisted setup RED LED lights up sporadically GREEN LED lights up sporadically The LED and the LCD display are off The reaction of the door does not correspond to the LED signal The LCD or remote control does not react The sensor signals an internal fault The power supply is too low or too high The sensor receives not enough IR energy The sensor receives too much IR energy The sensor is disturbed by external elements Faulty radar sensor output The internal test of the radar is disturbed IR power emitter is faulty Internal reference of the radar is faulty The sensor encounters a memory problem The sensor sees the door during the assisted setup The sensor vibrates The sensor sees the door The sensor is disturbed by external conditions The sensor is disturbed by rain and or leaves Ghosting created by door movement The sensor vibrates The sensor sees the door or other moving objects The sensor is protected by a password EF Replace sensor EH Check power supply in the diagnostics menu
9. on 1P54 Noise lt 70 dB Expected lifetime 20 years Applicable directives Detection mode R amp TTE 1999 5 EC MD 2006 42 EC LVD 2006 95 EC ROHS 2 2011 65 EU hb a op T g AA Cad Motion Min detection speed 5 cm s ine Pa Presence Typical response time lt 200 ms max 500 ms Technology Microwave doppler radar Active infrared with background analysis Transmitter frequency 24 150 GHz Spot 5 cm x 5 cm typ Transmitter radiated power lt 20 dBm EIRP Number of spots max 24 per curtain Transmitter power density lt 5 mW cm2 Number of curtains 2 Output Solid state relay potential and polarity free Solid state relay potential and polarity free Max contact current 100 mA Max contact current 100 mA Max contact voltage 42 V AC DC Max contact voltage 42 V AC DC Holdtime 0 3 to 1 s in switching mode NO NC in frequency mode pulsed signal f 100 Hz 10 Galvanically isolated current source No detection current source ON Open circuit voltage 6 5 V Output voltage available at 10 mA 3 V min Typical load up to 3 optocouplers in series Detection current source OFF Open circuit remained voltage lt 500 mV Test input Sensitivity Low lt 1 V High gt 10 V max 30 V Response time on test request typical lt 5 ms Norm conformity EN 12978 EN ISO 13849 1 2008 PL d CAT 2 EN 16005 2012 Chapter 4 6 8 DIN 18650 1 2010 Chapter 5 7 4 AutSchR BS 7036
10. rrent source output for emergency exits RADAR OUTPUT CONFIGURATION T ok E 0 RELAY OUTPUT NO normally open a wba NC normally closed Rad Qutput HE FREQUENCY OUTPUT paa ups 3O for emergency exits Frequency RPad Qutput CURRENT SOURCE OUTPUT ae O for emergency exits Cursent EJ RADAR OPENING IMPULSE FIELD field size 9 field size 9 immunity 2 ae Se immunity 2 ANGLE field size 9 immunity 2 field size 9 immunity 2 WIDTH 4m x 2 m wide 4 2m x 2 5 m narrow The size of the detection field varies according to the mounting height of the sensor In emergency exits the full door width must be covered PY INFRARED SAFETY FIELD ANGLE C E 4 A Gee fi Activate the visible spots to verify If necessary adjust the IR curtain the position of the IR curtain angle from 7 to 4 default 0 Visibility depends on external conditions When spots are not visible use the Spotfinder to locate the curtains The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf s Additional adjustments z are possible by LCD or remote control see p 5 Part of the detection field can be masked to reduce it Always verify the actual detection field width The arrow position determines the width of
Download Pdf Manuals
Related Search
Related Contents
Mitsubishi Electric WD510U Gama TopGear TG L/RBS Samsung ES 80 Quantum DPA Poster OPT99-IN-142 One Pass Fiber Pathway_壁面適合テスト説明書A HERMA Labels A4 48.3x25.4 mm white extra strong adhesion paper matt 1100 pcs. Operating instructions UPT-606 Dokument 1 - Dokumentenserverhosting der SUB VAIO User Guide Copyright © All rights reserved.