1. The power behind competitiveness Delta UPS Amplon Family M Series Single Phase 1 7 1 5 7 27 3 kVA User Manual IN NELTA www deltapowersolutions com Smarter Greener Together Save This Manual This manual contains important instructions and warnings that you should follow during the installation operation storage and maintenance of this product Failure to heed these instructions and warnings will void the warranty Copyright 2013 by Delta Electronics Inc All Rights Reserved All rights of this User Manual Manual including but not limited to the contents information and figures are solely owned and reserved by Delta Electronics Inc Delta The Manual can only be applied to the operation or the use of this product Any disposition duplication dissemination reproduction modification translation extraction or usage of this Manual in whole or in part is prohibited without the prior written permission of Delta Given that Delta will continuously improve and develop the product changes may be made to the information in this Manual at any time without obligation to notify any person of such revision or changes Delta will make all possible efforts to secure the accuracy and the integrity of this Manual Delta disclaims any kinds or forms of warranty guarantee or undertaking either expressly or implicitly including but not limited to the completeness faultlessness accuracy non infring
2. Figure 3 10 Place the UPS Inside the Tower Stands Optional Amplon M Series 24 Chapter 4 Connections Chapter 4 Connections e Pre connection warnings 1 Before connection please read Chapter 1 Important Safety Instructions thoroughly 2 The UPS is supplied with standard power cords and receptacles suitable for its use in your area of operation Only qualified service personnel can perform installation wiring operation and maintenance 3 Before connecting any input wiring to the UPS ensure that all circuits being used are the proper voltage and current required for the UPS The power supply to the UPS must be single phase in accordance with its rating label 4 Calculate the power consumption of the connected loads to ensure that an overload condition will not occur 5 Only 3kVA UPS can be connected to a Delta external battery pack If you plan to connect a Delta external battery pack to a 3kVA UPS please connect the battery pack to the UPS before UPS connection to the input power 6 Under EMC regulations output cables can not be longer than 10 meters and communication cables can not be longer than 3 meters 7 Prior to providing any power to the UPS the UPS must be suitably grounded The unit is equipped with a safety inspected mains line and must be connected to a wall socket with earthing contact If the wall socket does not have an earthing connection please ground the UPS via the ground terminal loc
3. 25 4 2 Connecting to Utility Power 27 4 3 Connecting the loads 27 Chapter 5 Operation 28 5 1 Operation Modes 28 5 2 Other Operating Details 28 HI A NELTA 5 3 Start up Procedure 30 5 4 Shutdown Procedure 30 5 5 UPS Self Test 31 5 6 Alarm 31 Chapter 6 Communication Interfaces 32 Chapter 7 Optional Accessories 34 Chapter 8 Maintenance 35 Bl UP Oe 35 8 2 Batteries 39 Chapter 9 Troubleshooting 36 Appendix 1 Specifications 39 Appendix 2 Warranty 41 Amplon M Series Chapter 1 Important Safety Instructions Chapter 1 Important Safety Instructions 1 1 Safety Instructions e Intended Use 1 This unit serves as a line interactive uninterruptible power supply UPS for connected loads 2 Neve
4. Communication interface port Please see Chapter 6 Communication Interfaces for detailed information Communication interface port Please see Chapter 6 Communication Interfaces for detailed information For UPS grounding Cools and ventilates the UPS Accepts SNMP Relay I O or ModBus card Please see Chapter 6 Communication Interfaces for detailed information Connect to the loads Protects the utility power from further damage when the UPS fails Please see 5 2 Other Operating De tails for detailed information Connects the UPS to the mains 16 e 2kVA 00 No 2 Item REPO Port USB Port RS232 Port Fan Smart Slot Output Outlet 16A Ground Terminal Output Outlets 10A Input Breaker AC Input 16A Chapter 2 Introduction Figure 2 3 2kVA Rear Panel Function Shuts down the UPS completely Please see 5 2 Oth er Operating Details for more information Communication interface port Please see Chapter 6 Communication Interfaces for detailed information Communication interface port Please see Chapter 6 Communication Interfaces for detailed information Cools and ventilates the UPS Accepts SNMP Relay I O or ModBus card Please see Chapter 6 Communication Interfaces for detailed information Connects to the loads For UPS grounding Connect to the loads Protects the utility power from further damage when the UPS fails
5. Amplon M Series 10 Chapter 2 Introduction 4 If there is any damage or anything missing please immediately contact the dealer from whom you purchased the unit 5 If the UPS needs to be returned carefully repack the UPS and all of the accessories using the original packing material that came with the unit 2 3 Features User friendly LED indicators Output power factor 0 9 Cold start REPO function Input breaker protection Generator compatible Hot swappable internal batteries and Delta external battery pack Battery deep discharging protection Intelligent monitor software connectivity through RS232 port or USB port Provides the following functions via configuration of UPSentry 2012 software included in the provided CD SNMP card optional or ModBus card optional 1 Regular self test History logs for records and analysis Battery remaining time amp lock time estimate Real time power condition monitoring System shutdown control D 7 gt amp NN UPS schedule ON OFF 10 sec and deep discharging test 11 NELTA 2 4 Front Panel O OVERLOAD 100 6 O 29 Q ONLINE ON BATT s REPLACE BATT O O D Figure 2 1 Front Panel No Symbol Name Description 0 ON OFF 1 When the UPS is OFF press and hold this ON OFF Button button and release it when you hear one beep to turn on the UPS 2 When the UPS is ON press and hold this ON OFF button and release it when
6. 1 Please read pre connection warnings before connection 2 Use the provided input cable to connect the UPS and a wall socket with earthing contact If the wall socket does not have an earthing connection please ground the UPS via the ground terminal Please see 2 5 Rear Panel for ground terminal location 3 Check whether the S W F Site Wiring Fault LED illuminates or not If yes pull out the mains plug turn it and plug it correctly Please note that the left pin of the UPS s AC input socket is L phase If the S W F LED still illuminates please contact service personnel NOTE 1 The UPS will charge its internal batteries and the Delta external battery pack if the Delta external battery pack is connected and its circuit breaker is turned on whenever the UPS is connected to an AC source There is an acceptable AC voltage present 2 It is recommended that you charge the UPS s batteries for a minimum of 6 hours before use If you don t do this the UPS may be used immediately but the On Battery runtime may be less than normally expected 3 If the UPS is going to be out of service or stored for a prolonged period of time you must recharge the internal batteries at least 6 hours once every 3 months If a Delta external battery pack is connected the recharging time should not be less than 12 hours 4 The batteries will immediately begin charging upon availability of the input power 4 3 Connecting the loads 1 Pl
7. 8 1 UPS e UPS Cleaning Regularly clean the UPS especially the slits and openings to ensure that the air freely flows into the UPS to avoid overheating If necessary use an air gun to clean the slits and openings to prevent any object from blocking or covering these areas e UPS Regular Inspection Regularly check the UPS every half year and inspect 1 Whether the UPS LEDs and alarm function are operating normally 2 Whether battery voltage is normal If battery voltage is too high or too low find the root cause 8 2 Batteries The M series UPS uses sealed lead acid batteries Though the typical battery life cycle is 3 years the battery life depends on the temperature the usage and the charging discharging frequency High temperature environments and high charging discharging frequency will quickly shorten the battery life The UPS does not require maintenance by the user however the batteries should be checked periodically Please follow the suggestions below to ensure a normal battery lifetime e Keep usage temperature at 25 C e When the UPS needs to be stored for an extended period of time the batteries must be recharged once every three months and the charging time must not be less than 6 hours each time If a Delta external battery pack is connected the charging time should not be less than 12 hours NOTE If the UPS s internal batteries need to be replaced please con tact qualified service personnel During ba
8. Leave adequate space at least 15cm in front and rear of the UPS for proper ventilation e Tower mounting procedures 1 Remove the four screws from the front plastic panel See Figure 3 5 Figure 3 5 Remove the Front Plastic Panel 2Y From the back of the front plastic panel carefully push the backside of the operation panel until it slides out of the front plastic panel Please handle with care to avoid damaging the cable connecting the operation panel and the UPS s internal connector See Figure 3 6 Amplon M Series 22 Chapter 3 Installation Panel Figure 3 6 Push the Backside of the Operation Panel 3 Rotate the operation panel 90 clockwise and reinstall it back into the front plastic panel Replace the front plastic panel and make sure the four screws are tightly fixed See Figure 3 7 Figure 3 7 Rotate the Operation Panel 90 Clockwise Reinstall It and Replace the Front Plastic Panel 4 Assemble the tower stands optional by inserting the tenons into the groo ves according to the size of the UPS See Figure 3 8 Figure 3 8 Assemble the Tower Stands Optional 23 A NELTA 5 Carefully lift the UPS upright at least two people are required with the Delta logo shown on the operation panel facing up See Figure 3 9 Figure 3 9 Place the UPS Upright 6 gt Place the UPS inside the tower stands at least two people are required See Figure 3 10
9. Graph LEDs please refer to 2 4 Front Panel You can use the UPSentry 2012 software included in the provided CD SNMP card optional or ModBus card optional to monitor and estimate the battery remaining capacity before or during an AC power failure For more infor mation about the SNMP card optional or the ModBus card optional please refer to its user manual 5 2 Other Operating Details 1 Please refer to 2 4 Front Panel 2 5 Rear Panel and Chapter 6 Communica tion Interfaces to understand how to use the UPS interfaces 2 Cold Start The UPS is able to start up via battery source when there is no AC power available 3 Site Wiring Fault Detection The unit can detect if input line and input neutral have been inverted If yes the S W F LED on the front panel will illuminate red 4 Battery Test The UPS can perform battery test manually upon user request or automatically For automatic regular test please install the UPSentry 2012 software included in the provided CD or configure the SNMP card optional Amplon M Series 28 Chapter 5 Operation or ModBus card optional For manual battery test only applicable for online mode please press and hold the MUTE TEST button H and release it when you hear four beeps to let the UPS perform a 10 second self test Generator Compatible The UPS can operate with most of the generators available in the market REPO Function The REPO port on the rear of the UPS all
10. can be connected to a Delta external battery pack 3 Only qualified service personnel can perform installation If you want to install the UPS and the Delta external battery pack by yourself installation must be under the supervision of qualified service personnel Installation Data Item Installation environment Operating temperature Relative humidity non condensing Max altitude without de rating Input power connection Output power connection Battery power connection Only for 3KVA model Air inlet Air outlet 19 Specification Indoor only 0 C 40 C 0 95 3 000 meters above sea level Rear Rear Rear Front Rear NELTA 3 2 Rack Mounting the UPS or the Delta External Battery Pack Optional You can rack mount the UPS and the Delta external battery pack only applicable for 3kVA model in four post frames The UPS and the Delta external battery pack use identical mounting kits and their mounting procedures are the same NOTE 1 The UPS draws cooling air from its front If your rack has a door on the front make sure that there is sufficient clearance between the UPS vents and the rack door 2 It is strongly recommended that at least two people lift the unit for rack mounting If there is only one person available we suggest that the UPS s internal batteries should be taken out less weight before rack mounting After rack mounting reinstall the internal batteries 3 Only us
11. one beep to turn on the UPS If the UPS is first turned on with AC applied the unit will perform a 5 second self test 5 4 Shutdown Procedure When the UPS is ON press and hold the ON OFF button A and release it when you hear one beep to turn off the UPS Though you have turned off the unit the UPS continues charging the batteries whenever it is plugged into a wall outlet and there is acceptable AC voltage present Amplon M Series 30 5 5 UPS Self Test 1 Chapter 5 Operation If the UPS is first turned on with AC applied the unit will perform a 5 second self test When the UPS is ON and runs in online mode press and hold the MUTE TEST button fgg release it when you hear four beeps and the UPS performs a 10 second self test You can use the UPSentry 2012 software included in the provided CD the SNMP card optional or the ModBus card optional to let the UPS perform a 10 second self test a regular test and battery deep discharging 5 6 Alarm No Condition Alarm 1 Battery The audible alarm sounds Mode once every ten second 2 Low The audible alarm beeps Battery twice every five second 3 Battery Missing The audible alarm beeps Replacement three times every five Weak minute 4 Overload The audible alarm sounds constantly 5 Internal Fault The audible alarm sounds constantly when the UPS detects an internal fault LED ON BATT LED and BATT LED illuminate green ON BATT
12. the UPS 5 Install the UPS and the Delta external battery pack on a level and even surface 6 For tower mounting installation ensure that your chosen location s floor can bear the weight of the UPS the Delta external battery pack and tower stands optional 7 For rack mounting installation make sure your chosen cabinet can support the weight of the UPS the Delta external battery pack and rails that may be mounted in an associated rack You also need to take your chosen location s floor weight loading into consideration 8 For rack mounting installation do not allow your rack to become top heavy Install the heaviest equipment near the bottom of the rack 9 Weights for the UPS and the Delta external battery pack are shown in Appendix 1 Specifications 10 Install the UPS in accordance with the conditions specified in 3 1 Installation Data 5 The ideal operating temperature range is 0 C 40 C e General Warnings 1 Electrical shock hazard even when the UPS is disconnected from the mains hazardous voltages may still exist at the output receptacles of the UPS Before maintenance cut off not only the AC source but also the battery source 2 Even when all switches and or circuit breakers are open dangerous voltages are present within this unit 3 Forbid opening or removing the cover of the UPS to avoid high voltage electric shock There are no user serviceable parts inside 4 Maintenance service must
13. 5 LED and 50 LED will illuminate and 75 LED will flash 14 Chapter 2 Introduction No Symbol Name Description 100 C 15 LS 50 D 25 d Bar Graph LEDs 5 When the total load is 75 100 of the rated capacity 25 LED 50 LED and 75 LED will illuminate and 100 LED will flash 6 When the total load is gt 100 of the rated capacity all Bar Graph LEDs will illuminate Please refer to 5 2 Other Operating Details for overload infor mation Battery Bar Graph LEDs 1 When the remaining battery capacity is 0 no Bar Graph LED will illuminate 2 When the remaining battery capacity is 0 25 25 LED will flash 3 When the remaining battery capacity is 25 50 25 LED will illuminate and 50 LED will flash 4 When the remaining battery capacity is 50 75 25 LED and 50 LED will illuminate and 75 LED will flash 5 When the remaining battery capacity is 75 100 25 LED 50 LED and 75 LED will illuminate and 100 LED will flash 6 When the remaining battery capacity is 100 all Bar Graph LED will illuminate 15 A NELTA 2 5 Rear Panel e 1KkVA 1 5kVA No Item REPO Port USB Port RS232 Port Ground Terminal Fan Smart Slot Output Outlets 10A Input Breaker AC Input 10A Amplon M Series Q Figure 2 2 1kVA 1 5kVA Rear Panel Function Shuts down the UPS completely Please see 5 2 Oth er Operating Details for more information
14. LED illuminates green and BATT LED flashes green REPLACE BATT LED illuminates red OVERLOAD LED illuminates red FAULT LED illuminates red NOTE After reconnecting or replacing the batteries it might take a while for the UPS to switch off the alarm automatically If after a period of time the audible alarm still exists user must initiate a self test press and hold the MUTE TEST button H and release it after you hear four beeps to clear the alarm NELTA Chapter 6 Communication Interfaces NOTE The UPS can still function properly without making the connections below The M series UPS s communication interfaces include an RS232 port a USB port and a smart slot Please refer to 2 5 Rear Panel for their locations You can use all of the communication interfaces at the same time and it won t influence each interface s function e RS232 Port You can use the provided RS232 cable to connect the UPS with a computer and use the included CD to install the UPSentry 2012 software to record UPS power events set up alarms and shut down the UPS safely in a network environment The pin assignment of this RS232 port is defined as follows Figure 6 1 RS232 Port RS232 Pin Assignment Description ya UPS TXD Typical RS232 level 3 UPS RXD Typical RS232 level 5 GND Communication setting for RS232 port Baud Rate 2400 Data Length 8 bits Stop Bit 1 bit Parity None Amplon M
15. On Green LED 2 Illuminates to indicate the connected loads status For occupied rated capacity please check Bar Graph LEDs 13 A NELTA No Symbol Name Description O D BATT 1 LED On Green BATT LED 2 Illuminates to indicate the battery capacity status For battery remaining capacity please check Bar Graph LEDs O o SWF 1 LED On Red SWE Li Site Wiring 2 llluminates when the UPS detects a site wiring Fault LED problem e g phase reversal grounding missing and improper grounding Please note that the left pin of the UPS s AC input socket is L phase REPLACE 1 LED On Red REPLACE BATT BATT 2 lluminates when the UPS detects a weak battery a LED 12 LJ ON BATT bad battery or a disconnected battery 1 LED On Green oewis LED 2 Iuminates when the UPS is operating in battery mode W BarGraph 1 LED On Green LEDs 2 In online mode the Bar Graph LEDs illuminate or B5 flash to indicate the occupied rated capacity L In battery mode the Bar Graph LEDs illuminate or Ca flash to indicate the reaming battery capacity H e Load Bar Graph LEDs Amplon M Series 1 When the total load is 0 of the rated capacity no Bar Graph LED will illuminate 2 When the total load is 0 25 of the rated capacity 25 LED will flash 3 When the total load is 25 50 of the rated capacity 25 LED will illuminate and 50 LED will flash 4 When the total load is 50 75 of the rated capacity 2
16. Please see 5 2 Other Operating De tails for detailed information Connects the UPS to the mains 17 A NELTA e 3kVA O 606 Oo O Figure 2 4 3kVA Rear Panel No Item 2 REPO Port USB Port RS232 Port Fan Smart Slot Output Outlet 16A Ground Terminal External Battery Pack Connector Output Outlets 10A Input Breaker AC Input 16A Amplon M Series Function Shuts down the UPS completely Please see 5 2 Oth er Operating Details for more information Communication interface port Please see Chapter 6 Communication Interfaces for detailed information Communication interface port Please see Chapter 6 Communication Interfaces for detailed information Cools and ventilates the UPS Accepts SNMP Relay I O or ModBus card Please see Chapter 6 Communication Interfaces for detailed information Connects to the loads For UPS grounding Connects to a Delta external battery pack Please see 4 1 Delta External Battery Pack Connection for de tailed information Connect to the loads Protects the utility power from further damage when the UPS fails Please see 5 2 Other Operating De tails for detailed information Connects the UPS to the mains 18 3 1 No 1 Chapter 3 Installation Chapter 3 Installation NOTE 1 Before installation please read Chapter 1 Important Safety Instructions thoroughly 2 Only 3kVA UPS
17. Series 32 Chapter 6 Communication Interfaces RS232 Other Pin Applications Alarm Signal amp Remote Shutdown Condition Pin Action The signal activates when the battery capacity is below Battery Low 1 the pre alarm threshold The signal activates when the mains voltage at the UPS input is not present or the mains voltage is out of the AC ray tolerance range The signal will be off following mains restoration SumAlarm 8 The signal activates when an internal fault is detected Remote shutdown is ONLY applicable to battery Remote 3 amp 6 mode For remote shutdown short Pin 3 and Pin 6 for Shutdown approximate 5 seconds and then the UPS will shutdown after 60 seconds El NOTE Other pins are reserved and cannot be used USB Port Besides RS232 port the UPS also provides another channel USB port for user to monitor the UPS status via a computer Simply plug a USB cable not provided into the UPS and your computer install the UPSentry 2012 software included in the provided CD and follow the prompts on your screen to complete the software installation Smart Slot You can choose optional cards to monitor the UPS or to enhance the UPS func tion The list of optional cards is shown in the table below Optional Card Function SNMP Card Helps you remotely monitor and control the status of IPv4 or IPV6 the UPS via a network system Relay I O Card Increases the quantity of dry contacts ModBus Card Lets the
18. UPS have ModBus communication NOTE For more detailed information about optional cards please con tact service personnel If you need to purchase any optional card please contact your local dealer or customer service 33 A NELTA Chapter 7 Optional Accessories oa There are several optional accessories available for this M series UPS Please refer to the table below for the optional accessories and their functions No Item Function 1 Tower Stands 2 Delta External Battery Pack 3 EnviroProbe 4 SNMP Card IPv4 or IPv6 5 Relay I O Card 6 ModBus Card NOTE Sustain the UPS vertically Provides external batteries that let the UPS supply power to the loads connected when a power failure occurs Monitors temperature humidity and other conditions in a room environment NOTE The EnvioProbe should work with either an SNMP card or an EMS2000 Monitors and controls the status of the UPS via a network system Increases the quantity of dry contacts Lets the UPS have ModBus communication function 1 For detailed installation and operation of any accessory mentioned above please refer to the Quick Guide User Guide or Installation amp Operation Guide included in the package of the relevant optional accessory 2 If you want to buy any accessory mentioned above please contact your local dealer or customer service Amplon M Series 34 Chapter 8 Maintenance Chapter 8 Maintenance
19. ating at the rear of the UPS Please see 2 5 Rear Panel 4 1 Delta External Battery Pack Connection E NOTE 1 Please read pre connection warnings before connection 2 If a Delta external battery pack needs to be used only applicable for 3kVA model connect the battery pack to the UPS prior to UPS connection to the input power Please note that only one Delta external battery pack can be connected 25 NELTA Please see the following figure for the rear view of the Delta external battery pack DC Battery Delta External Breaker Cable Battery Pack Figure 4 1 Delta External Battery Pack Rear View To connect a Delta external battery pack follow the steps below 1 Set the battery pack s DC breaker to the OFF position 2 Remove the cover of the external battery pack connector locating on the rear side of the UPS 3 Connect the battery cable attached to the Delta external battery pack to the UPS s battery pack connector Make sure the battery cable s iron strip shown in the figure below is tightly screwed Please see Figure 4 2 Screw Iron Strip Delta External Battery Pack Figure 4 2 Connect the UPS and the Delta External Battery Pack 4 Set the battery pack s DC breaker to the ON position 5 Adjust the battery pack number reported in the UPSentry 2012 software included in the provided CD to be equal to one Amplon M Series 26 Chapter 4 Connections 4 2 Connecting to Utility Power
20. be performed by qualified service personnel Only qualified service personnel can carry out any operation that requires protection panels to be opened and or removed 5 Any repairs or modifications by the user may result in out of warranty repair charges or unsafe electrical conditions Amplon M Series 2 Chapter 1 Important Safety Instructions 6 Do not use extension cords to connect the UPS to an AC outlet 7 Do not plug the UPS input cord into its own output receptacles e Usage Warnings 1 Before usage you must unpack the UPS and allow it to adjust to room temperature 20 C 25 C for at least two hours to avoid moisture condensing inside the UPS 2 The external slits and openings in the UPS are provided for ventilation To ensure reliable operation of the UPS and to protect the UPS from overheating these slits and openings must not be blocked or covered Do not insert any object into the slits and openings that may hinder ventilation 3 Even though all buttons are in the OFF position the UPS is not isolated from the mains To completely isolate the UPS from the mains please disconnect the input power cord 4 This unit supplies power from two sources the mains and the batteries The output receptacles may have voltage present even when the unit is unplugged Unplugging the UPS puts it into battery mode and the batteries supply power to the connected loads 5 Route all cords well so that nobody can stand on them or tri
21. dangerous high voltage is possible when the batteries are still connected to the UPS even though the UPS is disconnected from the mains Do not forget to pull out the battery cable to completely cut off the battery source Voltage is always present on the battery terminals Even when discharged a battery has the capacity to supply a high short circuit current which in addition to causing damage to the battery itself and to associated cables may expose the operator to the risk of burns Do not keep batteries in storage for periods exceeding 6 months at 25 C without being recharged having been charged to 100 at the beginning of any such period If these conditions are not met the battery performance can no longer be guaranteed It is recommend that you recharge the internal batteries at least once every 3 months and each recharging time should not be less than 6 hours If a Delta external battery pack is connected the recharging time should not be less than 12 hours Since new batteries often do not provide full capacity after an initial charge it may be necessary to carry out a number of discharge recharge cycles before optimum performance is achieved Servicing of batteries and battery packs should be performed or supervised by qualified service personnel knowledgeable in batteries battery packs and the required precautions Only use the same type of batteries from the same supplier Never use old new and different Ah batteries a
22. e e CE CB Report by TUV EN 62040 1 e EMC EN62040 2 C1 Amplon M Series 6 Chapter 1 Important Safety Instructions 1 4 Storage e Prior to installation If the UPS needs to be stored prior to installation it should be placed in a dry area The allowable storage temperature and relative humidity non condensing are 15 C 45 C and 0 95 respectively e After usage Press the ON OFF button FA make sure the UPS is shutdown disconnect the UPS from the utility power remove all equipment from the UPS and store the UPS in a dry and well ventilated area at a temperature between 15 C and 45 C and at a relative humidity non condensing between 0 95 Idle batteries must be recharged fully approximately every three months if the UPS needs to be stored for an extended period of time The charging time must not be less than 6 hours each time If a Delta external battery pack is connected the recharging time should not be less than 12 hours NOTE After storage and before start up of the UPS you must allow the UPS to adjust to room temperature 20 C 25 C for at least two hours to avoid moisture condensing inside the UPS 7 NELTA Chapter 2 Introduction 2 1 General Overview The M series UPS available in 1kVA 1 5kVA 2kVA and 3kVA is a line interactive UPS providing sine wave quality power to your electronic equipment Each kVA model has internal batteries and only 3kKVA model can be connected to a Del
23. e the provided bracket ears and rail kits to perform rack mounting NEVER depend on lower devices to support other devices e Rack mounting procedures 1 gt Attach the included bracket ears to the lateral mounting holes of the UPS See Figure 3 1 Figure 3 1 Mount the Bracket Ears 2 Adjust the length of the provided rails according to your rack and tighten the nuts See Figure 3 2 Amplon M Series 20 Chapter 3 Installation Figure 3 2 Adjust the Rails and Tighten the Nuts 3 Use the provided eight screws and eight washers to attach the rails to your rack See Figure 3 3 Figure 3 3 Attach the Rails to Your Rack 4 Insert the UPS into the rack and tighten the provided four screws See Figure 3 4 Please note that there will be extra four screws left after installation The four screws are spare parts Figure 3 4 Insert the UPS into Your Rack 21 A NELTA 3 3 Tower Mounting the UPS or the Delta External Battery Pack Optional You can mount the UPS or the Delta external battery pack only applicable for 3KVA model in an upright position by following the procedures below The UPS and the Delta external battery pack use identical mounting kits and their mounting procedures are the same Please note that the package does not include any tower mounting kits If you need to purchase any please contact Delta customer service NOTE 1 The tower stand picture shown below is just descriptive 2
24. ease read pre connection warnings before connection 2 Calculate power consumption of your loads to ensure that an overload condition will not happen 3 1kVA 1 5KVA model has 10A output outlets in the rear 2kKVA 3KVA model has 10A output outlets and a 16A output outlet in the rear 4 The package of 1kVA 1 5kVA model has one output cable 10A The package of 2kVA 3kVA model has two output cables 10A amp 16A Please follow your loads to select proper cables to connect the UPS output outlets with the loads 27 A NELTA Chapter 5 Operation E au 5 1 Operation Modes e Online Mode During online mode the ONLINE LED green and the LOAD LED green il luminate If loads are connected to the UPS the Bar Graph LEDs green will illuminate or flash to indicate the occupied rated capacity For information about the Bar Graph LEDs please refer to 2 4 Front Panel In online mode the connected loads are supplied by the utility AC power and the UPS charges the batteries as needed and provides power protection to the connected loads from a variety of power line problems e Battery Mode When the UPS is operating during a power outage the batteries provide DC power which maintains inverter operation to support the loads During battery mode the ON BATT LED green and the BATT LED green illuminate and the Bar Graph LEDs green illuminate or flash to indicate the reaming battery capacity For information about the Bar
25. ement merchantability or fitness for a particular purpose of the Manual Amplon M Series Il Table of Contents Table of Contents Chapter 1 Important Safety Instructions 1 1 1 Safety Instructions 1 1 2 Glossary of Symbols 1 3 Standard Compliance 6 1 4 Storage 7 Chapter 2 Introduction 8 2 1 General Overview 8 2 2 Package Inspection 8 2 3 Features 11 2 4 Front Panel 12 2 0 Rear Panel 16 Chapter 3 Installation 19 3 1 Installation Data 19 3 2 Rack Mounting the UPS or the Delta External Battery Pack Optional 20 3 3 Tower Mounting the UPS or the Delta External Battery Pack Optional 22 Chapter 4 Connections 25 4 1 Delta External Battery Pack Connection
26. expected after charging replace the batteries even if the REPLACE BATT LED doesn tt illuminate If a Delta external battery pack is used check if the DC breaker is turned on DELTA NO Problem Possible Cause Solution 10 No communi Wrong connection Check whether the connection cation between cable is used cable is correct or not the UPS and D your PC The connection Connect the communication cable cable is not firmly firmly connected You PC s interface Check if there is other software or is being used by service accessing the interface on another process or your PC or try to select a different is defective serial interface There is interfer 1 Lay the cable differently or ence on the con reconnect the cable nection cable 2 Check if any high current ca bles nearby If yes route the connection cable away from the high current cables Amplon M Series 38 Appendix 1 Specifications Appendix 1 Specifications Model M 1K M 1 5K M 2K M 3K Capacity Power Ratin 1 kVA 1 5 KVA 2 kVA 3 kVA d d J 0 9 kW 1 35 kW 1 8 kW 2 7 KW Nominal Nominal Voltage 220 230 240 Vac Single Phase 220 Vac 180 Vac 266 Vac Voltage Range 230 Vac 188 Vac 278 Vac 240 Vac 196 Vac 290 Vac 50 60 Hz 5 Hz Auto selectable 220 230 Default 240 Vac Single Phase CCS O Overload 111 125 Shutdown after 20 sec Online mode amp 126 150 Shutdown after 10 sec battery mode gt 150 Shutdow
27. mly connected Amplon M Series 36 ly NO Problem 4 FAULT LED illuminates S W F LED illuminates ONLINE LED illuminates but there is no output REPLACE BATT LED illuminates OVERLOAD LED illumi nates amp buzzer beeps con stantly In battery mode the UPS does not provide expected runtime Possible Cause An internal fault has been detected 1 Phase reversal on input power has been detected 2 Something wrong with your building wiring e g rever sed polarity The output cable is not firmly con nected Weak batteries bad batteries or poor battery connec tions The UPS is overlo aded The batteries might be weak or the lifetime is due The Delta exter nal battery pack s DC breaker is not turned on 37 Chapter 9 Troubleshooting Solution Contact service personnel 1 Pull out the input cable turn it and plug it correctly Please note that the left pin of the UPS s AC input socket is L phase 2 Contact a qualified electrician to check your building wiring Connect the output cable firmly If the problem still exists please con tact service personnel Charge the batteries for 6 hours replace the batteries or check the battery connections 1 Decrease some loads 2 Refer to 5 2 Other Operating Details to clear an overload war ning Charge the batteries for 6 hours and retest the runtime If the run time is still less than
28. n immediately Efficiency gt 97 gt 97 gt 96 gt 96 Online mode Efficiency AVR mode ame Internal Nominal Voltage 36 Vdc 36 Vdc 72 Vdc 72 Vdc gt 4 minutes full load Internal gt 10 minutes half load Batteries Charging Capacity 6 hours to 90 Standard RS232 USB Smart Slot REPO 39 NELTA Back up Time Model M 1K M 1 5K M 2K M 3K nsing Relative Humidity 0 95 non conde Environ ment nn A nn A re Noise ameter lt 45 dBA lt 45 aBA lt 60 amA lt 60 amA Display LEDs 0 40 C Dimensions WxDxH Weight 18 5kg 19 2kg 33kg 34 7kg Physical connector IEC 320 C14 IEC 320 C20 P Q ty 1 PC Q ty 1 PC IEC 320 C13 IEC 320 C13 Q ty 2x4 PCS Q ty 2x4 PCS IEC 320 C19 Q ty 1 PC 440 x 429 4 x 88 5 mm 440 x 608 x 88 5 mm Output Connector e CE Standard CB Report by TUV Compli Certification e EN 62040 1 ance e EMC EN62040 2 C1 Delta External Battery Pack Optional and Only Applicable for 3 KVA Model 440 x 429 4 88 5 mr NOTE 1 Refer to the rating label for the safety rating 2 All specifications are subject to change without prior notice Amplon M Series 40 Appendix 2 Warranty Appendix 2 Warranty Seller warrants this product if used in accordance with all applicable instructions to be free from original defects in material and workmanship within the warranty period If the product has any fail
29. ows user to shut down the UPS when an emergency occurs Use a RJ11 cable to connect the REPO port and a user supplied switch In online mode or in battery mode short pin 4 to pin 5 for approximately 0 5 second to shutdown the UPS Pin 6 e Pin 1 e WARNING Do not connect a telephone line to Figure 5 1 REPO Port this REPO port Online Mode Battery Mode Overload Cut off 1 When the UPS is 110 125 overloaded either in online mode or in battery mode the OVERLOAD LED will illuminate the alarm will sound constantly and the UPS will completely shutdown within 20 seconds 2 When the UPS is 125 150 overloaded either in online mode or in battery mode the OVERLOAD LED will illuminate the alarm will sound constantly and the UPS will completely shutdown within 10 seconds 3 When the UPS is gt 150 overloaded either in online mode or in battery mode the OVERLOAD LED will illuminate the alarm will sound constantly and the UPS will immediately shutdown 4 To clear an overload warning e In Online Mode After auto shutdown the overload alarm will be off the OVERLOAD LED will be still on and the UPS will work in standby mode Press the ON OFF button 1 to let the UPS run in online mode After that the OVERLOAD LED will be off e In Battery Mode After auto shutdown the overload alarm and the OVERLOAD LED will be off 29 A NELTA 8 Input Breaker 1 In Online Mode e When an over current is
30. p over them 6 When connecting the unit to the power supply follow the instructions stated in Chapter 4 Connections 7 Ensure that no objects e g rings necklaces paper clips etc get inside the unit 8 In an emergency switch off the unit disconnect it from the mains and contact the responsible customer service representative 9 Do not connect equipment that will overload the UPS and demand DC current 10 Do not connect or disconnect data transmission lines during a thunderstorm 11 The sum of current leakage from the UPS and its connected loads must not exceed 3 5 mA 12 The UPS has a REPO remote emergency power off port locating on the rear Please see 5 2 Other Operating Details for more information 13 The UPS must be well grounded due to a possible risk of current leakage The unit is equipped with a safety inspected mains line and must be 3 DELTA connected to an earthing contact wall socket If the wall socket does not have an earthing connection please ground the UPS via the ground terminal locating at the rear of the UPS please see 2 5 Rear Panel 14 Ensure that the sockets on the unit or the earthing contact wall socket is freely accessible e Battery Precautions 1 Do not open or mutilate the battery or batteries The released electrolyte is harmful to the skin and eyes and may be toxic Do not dispose of the battery or batteries in a fire The batteries may explode The risk of
31. r connect a laser printer or scanner to the UPS This may cause damage to the unit 3 The UPS is available in 1kVA 1 5kVA 2kVA and 3kVA Each model has internal batteries 4 Only 3kVA model can be connected to a Delta external battery pack optional 5 The UPS can be used to power computers and associated peripheral devices such as monitors modems cartridge tape drives external hard drives etc e Handling Transport the unit only in suitable packaging to protect it from jolts and shocks The UPS must be kept upright at all times and handled with care e Placement amp Installation Warnings 1 Install the UPS in a well ventilated area away from extremes of temper ature excess moisture heat dust flammable gas or explosives 2 Leave adequate space at least 15cm in front and rear of the UPS for proper ventilation 3 Electrical maintenance and service requires access to the front and back of the UPS Leave necessary space to allow service personnel to access to the UPS 4 The UPS can be installed vertically tower mounting or horizontally rack mounting depending on user s desired arrangement Please obey the following 1 Do not mount the UPS with its front or rear panel facing down at any angle 1 NELTA 2 Keep the UPS upright at all times and handle it with care 3 Do not stack units 4 Do not place any objects on the UPS the Delta external battery pack or any other accessory associated with
32. sue occurs the input breaker on the rear of the UPS will automatically activate and the unit will transfer to battery mode After the abnormal issue is solved press this input breaker and the unit will automatically switch back to online mode you don t need to press the ON OFF button W to start up the UPS e f an over current issue occurs the input breaker on the rear of the UPS will automatically activate If there is no battery power the UPS will au tomatically shutdown After the abnormal issue is solved press the input breaker and the unit will automatically run in online mode you don t need to press the ON OFF button W to start up the UPS 2 In Battery Mode e When an over current issue occurs the input breaker on the rear of the UPS will automatically activate and the unit will still run in battery mode After the abnormal issue is solved press the input breaker and the unit will automatically switch back to online mode you don t need to press the ON OFF button W to start up the UPS NOTE When the input breaker automatically activates it means that something wrong with the UPS or its connected loads It is highly recommended that you turn off the UPS remove the input power cord and let qualified service personnel carefully inspect the UPS its connected loads and the surrounding environments 5 3 Start up Procedure When the UPS is OFF press and hold the ON OFF button FA and release it when you hear
33. t the same time 10 A battery can present a risk of electrical shock and high short circuit current Amplon M Series 4 Chapter 1 Important Safety Instructions The following precautions should be observed before replacement of batteries 1 Remove watches rings or other metal objects 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting battery terminals e Disposal 1 To protect our environment UPS amp batteries must be disposed of in accord ance with local laws and regulations 2 For proper UPS amp battery disposal contact your local recycling reuse or hazardous waste center WARNING You must contact qualified service personnel if either of the following events occur 1 Liquid is poured or splashed on the UPS or on the Delta external battery pack 2 The UPS does not run normally after this User Manual is carefully observed 1 2 Glossary of Symbols No Symbol Description 1 ON OFF Button 2 MUTE TEST Button 3 M OVERLOAD LED OVERLOAD 4 Cd FAULT LED FAULT 5 NELTA Description 5 BOOST LED 6 C BUCK LED BUCK 7 J ONLINE LED ONLINE 8 M LOAD LED LOAD 9 D BATT LED BATT 10 S W F Site Wiring Fault LED 11 a REPLACE BATT LED BATT 12 eS ON BATT LED ON BATT 13 i Bar Graph LEDs 15 T 50 T 25 1 3 Standard Complianc
34. ta external battery pack The unit s output power factor is 0 9 and its efficiency in online mode full load can reach at minimum 97 and 96 for 1 1 5kVA and 2 3kVA respectively It produces greater electric power efficiency at less cost and its com pact design is perfect for IT applications 2 2 Package Inspection e External During UPS transportation some unpredictable situations might occur It is recommended that you inspect the UPS exterior packaging If you notice any damage please immediately contact the dealer from whom you purchased the unit e Internal 1 Check the rating label stuck on the top of the UPS and make sure the device No and capacity match what you ordered 2 Examine if any parts are loose or damaged 3 The UPS package contains the following items Please check if any items are missing Amplon M Series 8 Chapter 2 Introduction e For 1kVA 1 5kVA model 7 Gis x4 tee e E xs Item Quantity UPS 1 PC 2 User s Manual CD 1PC Software CD UPSentry 2012 1PC Quick Guide 1 PC O Bracket Ear 1 Set O Output Cable 10A 1PC Input Cable 10A 1PC RS232 Cable 1 PC O Rail Kit 1 Set 9 NELTA e For 2kVA 3kVA model No Item Quantity O UPS 1 PC 2 User s Manual CD 1 PC Software CD UPSentry 2012 1PC O Quick Guide 1 PC O Bracket Ear 1 Set O Input Cable 16A 1PC Output Cable 16A 1 PC Output Cable 10A 1 PC O Rail Kit 1 Set D RS232 Cable 1PC
35. ttery replacement the loads attached to the UPS will not be protected if input power fails 35 NELTA Chapter 9 Troubleshooting 1 When a problem occur please check if the following situations exist before contacting Delta service personnel e Is the mains voltage present at the UPS input e s the input breaker tripped 2 Please have the following information ready if you would like to contact the Delta service personnel e Unit information including model serial number etc e An exact description of the problem The more detailed description of the problem the better 3 When you see the following problems occur please follow the solutions shown below NO Problem Possible Cause Solution 1 NoLED The ON OFF Press and hold the ON OFF button illuminates button isnot W and release it when you hear No alarm turned on one beep to turn on the UPS goes off The mains voltage Please contact qualified electrician is not present to inspect the status of the mains 2 The UPS is The ON OFF Press and hold the ON OFF button not turned on button FA is not Fi and release it when you hear turned on one beep to turn on the UPS 3 The UPS The input breaker is Press the input breaker to reset it runs in battery tripped If the input breaker trips again after mode even the UPS starts up contact service when the AC personnel source is normal The input power Connect the input power cord firm cord is not fir
36. ure problem within the warranty period Seller will repair or replace the product at its sole discretion according to the failure situation This warranty does not apply to normal wear or to damage resulting from improper installation operation usage maintenance or irresistible force i e war fire natural disaster etc and this warranty also expressly excludes all incidental and consequential damages Maintenance service for a fee is provided for any damage out of the warranty period If any maintenance is required please directly contact the supplier or Seller WARNING The individual user should take care to determine prior to use whether the environment and the load characteristic are suitable adequate or safe for the installation and the usage of this product The User Manual must be carefully followed Seller makes no representation or warranty as to the suitability or fitness of this product for any specific application 41 DELTA NELTA Smarter Greener Together
37. you hear one beep to turn off the UPS NOTE If the UPS is first turned on with AC applied the unit will perform a 5 second self test Amplon M Series 12 Chapter 2 Introduction No Symbol Name Description 2 MUTE TEST OVERLOAD FAULT BOOST BUCK ONLINE LOAD MUTE 1 When the UPS is ON and runs in online mode press TEST and hold this MUTE TEST button and release it Button when you hear four beeps to let the UPS perform a 10 second self test 2 If a buzzer sounds press this MUTE TEST button and release it immediately after you hear one beep to silence the buzzer If you silence the buzzer the buzzer will still go off when a new abnormal event occurs OVERLOAD 1 LED On Red LED 2 luminates when the UPS is overloaded For more information about an overload condition please refer to 5 2 Other Operating Details FAULT 1 LED On Red LED 2 Illuminates when the UPS detects an internal fault BOOST 1 LED On Yellow LED 2 Blinks when the UPS is operating in boost mode to compensate input voltage discrepancy for an under voltage condition BUCK 1 LED On Yellow LED 2 Blinks when the UPS is operating in buck mode to compensate input voltage discrepancy for an over voltage condition ONLINE 1 LED On Green LED 2 illuminates when the UPS is on and operating in AC normal mode Please note that this LED also illuminates when the UPS runs in boost buck mode LOAD 1 LED
Download Pdf Manuals
Related Search
Related Contents
Samsung 2032MW Manual de Usuario A-FRNT.DOC - Bad Request usps gats informal payments educational user guide Samsung NV75J5540RS/EG Manuel de l'utilisateur dreamGEAR Radium, PS3 Whistler Motorcycle Bluetooth Headset O que é a SEPA? Manual - RayBiotech, Inc. W−CDMA電話機用USB接続ケーブル CS−10U 発売のご Introduction Installing AVR Studio and AVR-GCC Copyright © All rights reserved.