1. PATRIOT ELECTRIC FENCE ENERGIZER USER MANUAL PE2 PES PETO PESS PETOB If you suspect the unit is not working then follow these steps 1 Disconnect the unit from the fence STO pI 2 Check that the indicator light is flashing s 3 Check that the voltage between the fence and ground terminals DO NOT RETURN is greater than 4000 V using a Patriot Digital Voltmeter or THIS PRODUCT Fence Tester TO THE STORE 4 If these tests are OK you have an installation problem Consult your user manual for installation and operating instructions or contact Tru Test Customer service on 800 874 8494 WWW PATRIOTGLOBAL COM CH WARNING READ ALL INSTRUCTIONS Key to symbols on the unit Patriot PE2 PES PE10 PESB PETOB Fence ground terminal green Connect the fence ground terminal to the ground system Fence output terminal red Connect the fence output terminal to the fence Pulse indicator light i 3 F Unit is suitable for connection to AC 120 V Unit is suitable for connection to DC 6 V 12 V Risk of electric shock Do NOT open 4 f if O gt OO CAUTION Fence Fence CA Read full instructions before use ground output terminal terminal ol Double insulation no serviceable parts green red Instructions for PE2 PES and PE10 Installation Indoors dry locations with AC 120 V line connection 1 Connect the Fence ground terminal green to a separate ground system that is at least
2. afety considerations Warning PE5B and PE10B only Do not connect to AC 120 V operated equipment PE5B and PE10B only The unit must be located in a shelter and the cable must not be handled when the temperature is below 5 C PE2 PES and PE10 only To reduce the risk of electric shock the unit has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way Disconnect the unit from the supply before installation or performing any work on the fence Read all the safety considerations carefully Check your installation to ensure that it complies with all local safety regulations Do not connect simultaneously to a fence and to any other device such as a cattle trainer or a poultry trainer Otherwise lightning striking your fence will be conducted to all other devices Notes This product has been designed for use with electric animal fences Keep these instructions in a handy location 11 Safe electric fence construction Warning Read before use An electric fence can be hazardous when there is a risk of entrapment or entanglement or other hazards exist Serious injury or death may result Take all steps to avoid the risk of entrapment or entanglement Hazards Do not climb through or under a
3. be installed operated and maintained in a manner that minimises danger to persons animals or their surroundings This unit is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not play with the unit Electric animal fence constructions that are likely to lead to the entanglement of animals or persons shall be avoided 14 An electric animal fence shall not be suppl unit For any two separate electric anim between the wires of the two elec ric anim ied from two separate units or from independent fence circuits of the same al fences each supplied from a separate unit independently timed the distance al fences shall be at least 8 2 5 m If this gap is to be closed this shall be effected by means of electrically non conductive material or an isolated metal barrier Barbed wire or razor wire shall no A non electrified fence incorporati wires of an electric animal fence T that these wires are positioned at wires The barbed wire and razor wire sha be elec he supp a minim rified by a unit ng barbed wire or razor wire may be used to support one or more offset electrified orting devices for the electrified wires shall be construct
4. intervals by warning signs securely f signs hat is installed along a public road or pathway shall be identified at frequent astened to the fence posts or firmly clamped to the fence wires e The size of the warning sign shall be at least 4x8 100x200 mm e The background colour of both sides of the warning sign shall be yellow The inscription on the sign shall be black and shall be either or the substance of CAUTION 25 mm Electric fence The inscription shall be indelible inscribed on both sides of the warning sign and have a height of at least 1 13 Definition of special terms Unit Charger Energizer An appliance that is intended to periodically deliver voltage impulses to a fence connected to it Fence A barrier for animals or for the purpose of security comprising one or more conductors such as metal wires rods or rails Flectric fence A barrier which includes one or more electric conductors insulated from ground to which electric pulses are applied by a unit Ground electrode Metal structure that is driven into the soil near a unit and connected electrically to the Fence ground terminal of the unit and that is independent of other grounding arrangements Connecting lead An electric conductor used to connect the unit to the electric fence or the ground electrode Requirements for electric animal fences Electric animal fences and their ancillary equipment shall
5. peut tre dangereuse si elle pr sente un risque d embrouillement ou d emm lement ou que d autres risques existent Des blessures graves ou la mort peuvent en tre la cons quence Prenez les mesures n cessaires pour viter tout risque d embrouillement ou d emm lement Dangers e passez pas par dessus ou par dessous une cl ture lectrique Si vous devez traverser une cl ture lectrique utilisez une porte ou un passage sp cialement am nag e permettez jamais aux enfants ou des personnes ayant une quelconque infirmit d utiliser cet appareil sans supervision Ne laissez jamais jouer un enfant avec cet appareil ou proximit d une cl ture lectrique ou d un fil lectrifi lectrifiez jamais des fils barbel s installez jamais des fils lectrifi s d cal s moins de 6 150 mm d un fil barbel lectrifiez jamais une cl ture qui pourrait entra ner un risque d emm lement pour l homme ou les animaux Nous vous recommandons par exemple de n installer qu un seul fil d cal lectrifi par c t d un fil barbel ou d un grillage alimentez jamais une cl ture lectrique par deux lectrificateurs ix gt k Assurez toujours une distance d au moins 8 2 5 m entre des fils lectrifi s de deux appareils sur le m me lotissement ou un lotissement voisin e mettez jamais la prise de terre de l lectrificateur moins de 33 10 m de toute partie d une prise de terre d un r seau lectri
6. 33 10 m away from other ground systems 2 Connect the Fence output terminal red to the fence Operation Insulated underground fence cable 1 Plug the unit into the AC 120 V power supply 2 Turnon the AC 120 V power supply switch The pulse indicator light flashes each time the unit pulses Instructions for PESB and PE10B Installation and operation DC 6 V 12 V battery connection 1 Connect the Fence ground terminal green to a separate ground system that is at least 33 10 m away from other ground systems Connect the Fence output terminal red to the fence Connect the unit to a 6 V 12 V battery using the battery leads Attach the red clip to the positive terminal of the battery and the black clip to its negative terminal The pulse indicator light flashes each time the unit pulses To prevent damage caused by stock interference Battery enclosure Unit enclosure Insulated underground fence cable and bad weather house the battery and the unit in protective enclosures Battery information Use a 6 V 12 V rechargeable lead acid battery Do not dispose of the battery in a land fill or in a fire In the event of a spill or leakage from a lead acid battery e Contain small spills with dry sand earth and vermiculite Do not use combustible materials If possible carefully neutralise spi
7. B uniquement L unit doit tre mont l abri des intemp ries et le c ble n lorsqu il fait moins de 5 C PE2 PES et PE10 uniquement Pour r duire le risque d une secousse lectrique l unit a s par le r seau lectrique e doit pas tre manipul une fiche polaris e une lame est plus large que l autre Cette fiche ne rentre dans une prise polaris e que dans un sen s Si la fiche ne rentre pas enti rement dans la prise retournez la fiche Si elle ne rentre toujours pas contactez un lectricien qualifi pour installer la bonne prise Ne modifiez pas la fiche D connectez l unit du syst me d alimentation lectrique avant de proc der tout travail d installation ou toute autre intervention sur la cl ture Lisez attentivement toutes les r gles de s curit V rifiez soigneusement que votre cl ture est en conformit avec tous les r glements locaux de s curit Ne raccordez jamais un lectrificateur simultan ment une cl ture et un autre appareil tel qu un syst me de dressage de b tail ou de volaille Sinon la foudre pouvant tomber sur votre cl ture risque de s tendre tous les autres appareils Notes Ce produit a t con u pour une utilisation avec des cl tures lectriques pour anima Gardez ces instructions un endroit pratique UX 19 Installation d une cl ture lectrique s re Attention Lisez avant utilisation Une cl ture l ectrique
8. eceives a shock when it completes a circuit between a live wire and a ground wire The fence above has both live wires and ground wires not insulated to the post The ground wire is connected back to the grounding system Installing a ground system Select a suitable site for the ground system The site needs to be e At least 33 10 m from other ground systems e g telephone AC 120 V power or the ground system of another unit e Away from s ock or other traffic that could interfere with the installation e Ata site that can be easily observed for maintenance e Ideallyatas Note The site for ite that has damp soil e g a shaded or swampy location he ground system does not need to be directly adjacent to where the unit is installed Drive a single ground rod into the soil Use insulated cable to connect the ground rod to the unit s Fence ground terminal Ensure that there is a good electrical connection at both ends Temporary fence construction for DC units only Temporary fence components Gate handle Fence post Pigtail Permanent Tread in Tread in Fence post or temporary Permanent or temporar Ground rod poran Recommended wire spacing 16 5 m 32 800 mm Dairy cattle 16 5 m 10 250 mm Sheep 10 250 mm 16 5 m a 17 425 mm a e Li q 17 425 mm oo Cattle S
9. ed so as to ensure um distance of 6 150 mm from the vertical plane of the non electrified be grounded at regular intervals Go to www patriotglobal com for informat ion about grounding A distance of at least 33 10 m shall be maintained between the unit s ground electrode and any other grounding system connected parts such as the grounding system for the power supply or the telecommunication system Connecting leads that are run inside buildings shall be effectively insulated from the grounded structural parts of the building This may be achieved by using insulated high voltage cable Connecting leads that are run underground shall be run in conduit of insulating material or else insulated high voltage cable shall be used Care must be taken to avoid damage to the connecting leads due to the effects of animal hooves or vehicle wheels sinking into the ground Connecting leads shall not be installed in the same conduit as the AC supply wiring communication cables or data cables 15 Connecting leads and electric animal fence wires shall not cross above overhead power or communication lines Crossings with overhead power lines shall be avoided wherever possible If such a crossing cannot be avoided it shall be made underneath the power line and as nearly as possible at right angles to it If connecting leads and electric animal fence wires are installed near an overhead power line the clearances shall n
10. ement des impulsions lectriques a la cl ture connect e l lectrificateur Cl ture une barri re utilis e pour contenir des animaux ou pour des raisons de s curit qui comprend une ou plusieurs conducteurs tels fils m talliques piquets ou lattes Cl ture lectrique une barri re comprenant un ou plusieurs conducteurs lectriques isol e de la terre et soumise des impulsions lectriques g n r es par un lectrificateur Prise de terre structure m tallique enfonc e dans le sol proximit d un lectrificateur et connect e lectriquement la borne de terre de l lectrificateur structure s par e de tout autre syst me de mise la terre Fil de connexion un conducteur lectrique utilis pour relier l lectrificateur la cl ture lectrique ou la prise de terre 22 1 year from date of purchase This warranty does not cover defects caused by Incorrect input voltage or polarity e Damage to external wiring Physical mishandling Water immersion Vermin or insect damage This warranty covers defects caused by lightning Note This product has been manufactured to comply with international safety standards This product is warranted against faulty material and workmanship for a period of 1 year FROM DATE OF PURCHASE If a warranted defect occurs return this product with proof of purchase to an authorised service centre For details see www patriotglobal com Note No respo
11. lled acid with soda ash sodium bicarbonate lime etc e Wear acid resistant clothing boots gloves and a face shield e Do not let acid get into the sewage system e Neutralised acid must be managed in accordance with approved local state and federal requirements Consult your state environmental agency and or federal EPA Battery charging Warning Do not attempt to recharge a non rechargeable battery When recharging a battery ensure that there is adequate ventilation to allow gases to disperse The battery must be disconnected from the unit before connecting it to a battery charger Regular recharging of the battery is essential Use a suitably rated battery charger and refer to the battery manufacturer s recommendations Building an electric fence Note This product has been designed for use with electric animal fences For information about building an electric fence refer to the Patriot website www patriotglobal com Grounding a fence All live fence For most soil types IR ows E Al i 4 e e The animal receives a shock when it completes a c has all live wires and requires conductive soils 6 ircuit between the fence and the ground system The fence above Ground wire return fence For dry sandy or frozen ground conditions where soil conductivity is low we Ground IR ws The animal r
12. n electric fence If it is necessary to cross an electric fence use a gate or specially designed crossing point Do not allow young or infirm persons to use this unit without supervision Do not allow young children to play with this unit or near an electric fence or electrified wires Do not electrify barbed wire Do not support off set electrified wires less than 6 150 mm from a barbed wire fence Do not electrify any fence construction which could lead to entanglement of persons or animals We recommend for instance that no more than one electrified off set wire be supported on either side of a barbed wire or mesh fence Do not supply an electric fence from two units Do not allow electrified wires from two units on the same or adjacent properties to be less than 8 2 5 m apart Do not place the unit s ground electrode within 33 10 m of any part of a power supply ground system or telecommunications ground system Do not run electric fence wires above or close to overhead power or communication lines Duty to the public A warning sign shall be fitted to every point where persons may gain ready access to the conductors Where an electric animal fence crosses a public pathway a non electrified gate shall be incorporated in the electric animal fence at that point or a crossing by means of stiles shall be provided At any such crossing the adjacent electrified wires shall carry warning Any part of an electric animal fence
13. nsibility is accepted for any accident or damage caused subsequent to any tampering with or modification to or misuse of this product including but not limited to alterations made by anyone other than Tru Test Group or its agents To the maximum extent permitted by law this warranty is exclusive personal to you and in lieu of all other warranties representations or conditions relating to this product whether express or implied and whenever arising whether originating by statute law trade custom or otherwise SAVE THESE INSTRUCTIONS 23 RECOMMENDATIONS PE10B v v v SES DS SN Bog SN OR Ba SN DNS DS o DE DS oS ee PRR HT FOR USE WITH STEEL WIRE ALUMINUM WIRE SSI POLIWIRE POLIROPE s POLITAPE MANUFACTURED IN NEW ZEALAND INSTALLATION INSTRUCTIONS INSIDE
14. ot be less than those shown in the table below Minimum clearances trom power lines for electric animal fences Power line voltage Clearance lt 1000 V 10 3 m gt 1000 V to lt 33 000 V 13 4m gt 33 000 V 27 8 m If connecting leads and electric animal fence wires are installed near an overhead power line their height above the ground shall not exceed 10 3 m This height applies to either side of the orthogonal projection of the outermost conductors of the power line on the ground surface for a distance of e 6 6 2 m for power lines operating at a nominal voltage not exceeding 1000 V e 50 15 m for power lines operating at a nominal voltage exceeding 1000 V Electric animal fences intended for deterring birds household pet containment or training animals such as cows need only be supplied from low output units to obtain satisfactory and safe performance In electric animal fences intended for deterring birds from roosting on buildings no electric fence wire shall be connected to the unit s ground electrode 16 Ensure that all line operated ancillary equipment connected to the electric animal fence circuit provides a degree of isolation between the fence circuit and the supply mains equivalent to that provided by the unit Protection from the weather shall be provided for the ancillary equipment unless this equipment is certified by the manufacturer as being suitable for use outdoors Servicing This p
15. que ou de lignes de t l communi ication installez jamais des fils de cl ture lectrique au dessus ou pr s de lignes lectriques ou de t l communication a riennes Obligation envers le public Une plaque de signalisation doit tre mise en place partout o des personnes auront acc s aux conducteurs Partout o une cl ture lectrique pour animaux croise un chemin public une porte non lectrifi e sera incorpor e la cl ture lectrique pour animaux ou bien un passage au moyen d une chelle sera pr vu Les fils lectrifi s adjacents a ces passages doivent tre munis de plaques de signalisation Toute partie d une cl ture lectrique pour animaux install e le long d une voie publique ou d un sentier sera signal e des intervalles fr quents par des plaques de signalisation qui seront solidement attach es aux piquets ou accroch es la ligne de cl ture e La taille des plaques de signalisation sera au moins de 4x8 100x200 mm e La couleur de fond des plaques doit tre jaune des deux c t s L inscription sur la plaque doit tre en noir et soit indiquer le symbole ci dessous soit indiquer en substance ATTENTION Cl ture lectrique e L inscription doit tre ineffa able inscrite sur les deux c tes de la plaque de signalisation et avoir une hauteur minimale de 1 25 mm 21 D finitions des termes techniques Flectrificateur de cl ture appareil mettant r guli r
16. roduct is NOT serviceable Please refer to the warranty conditions at www patriotglobal com 17 CG ATTENTION LIRE TOUTES LES INSTRUCTIONS CED Consulte nuestra pagina web patriotglobal com para acceder a las instrucciones completas de instalacion y funcionamiento CH ADVERTENCIA LEA TODAS LAS INSTRUCCIONES CFD Pour les instructions compl tes d installation et d utilisation veuillez vous reporter notre site web patriotglobal com Explication des symboles sur l lectrificateur Borne de terre de la cl ture vert Connectez la borne de terre au syst me de mise la terre de l lectrificateur Borne de sortie vers la cl ture rouge Connectez la borne de sortie la cl ture Cet lectrificateur est con u pour tre utilis avec du courant alternatif de 120 V Cet lectrificateur est con u pour tre utilis avec du courant continu de 6 V et 12 V Risque de choc lectrique Ne pas ouvrir Lire attentivement toutes les instructions avant usage Double isolation ne contient pas de pi ces r parables TPO 8 Attention Attention Ne jamais charger une batterie non rechargeable Pendant le chargement de la batterie assurer une ventilation ad quate pour permettre aux gaz de se dissiper La batterie doit tre d connect e de l lectrificateur avant sa connexion a un chargeur PE5B et PE10B uniquement Ne jamais raccorder cet appareil des quipements alimen PE5B et PE10

Download Pdf Manuals

image

Related Search

Related Contents

maniglie P230j rev4.qxp  Installation des membres de la commission du  DNP 3.0 LAN/WAN Master (OPC) User`s Manual    Bulletin 3 / déc. 2008  KUDA 083100 holder  CL124 / CL140  Philips Voice Tracer digital recorder DVT5500  Manuel d`utilisation et d`installation Refroidisseur de gaz de mesure  Instruções de Uso - Fresa Titânio  