Home

- Eurotherm

image

Contents

1. Rated up to 50A at 45 C 240V and 480V options AC and DC logic input Partial load failure detection Simple installation and maintenance EUROTHERMe FLEXIBLE SOLUTIONS InvensySo EUROTHERM EUROTHERM E Solid State Relay Specification Sheet A compact low cost 240 and 480 volt solid state relay for 16 25 40 and 50 amps rated at 45 C Easy replacement for mechanical contactors Mechanical contactors in heating applications may operate three million times per year The lifetime of such contactors is 1 to 3 years so they need to be replaced several times during the life of an industrial machine Alternatively the TE10S from Eurotherme has no moving parts and will not wear out Its wiring is similar to contactors and it has simple DIN rail mounting It takes a broad range of AC and DC inputs with a front face LED to show the control signal to help commissioning and diagnostics Extend the life of your heaters Tests performed by a well known heater supplier have shown that heaters can last up to 7 times longer when driven by a solid state relay Faster on off cycle times cause less thermal expansion and contraction of the heaters to reduce breakage due to fatigue and thermo mechanical stress Your savings include the cost of the heaters installation costs scrap reduction and lost production The TE10S is able to detect element failures to heaters with multiple elements in parallel Why choose a fully assem
2. N 61000 4 3 EN55011 EN50081 2 without external filter optional parallel filters must be fitted for 2 phase control pf 3 phase loads Complies with Low Directive 73 23 EEC dated 19 2 73 amended by Directive 93 68 EEC dated 22 7 93 product installed and used in compliance with its user manual TE10S products carry the CE mark in compliance with the European Low Voltage Directive A CE declaration of conformity is available on request Ordering code 1 2 3 4 5 6 TE10S LGC Universal DC ENG English Partial load failure LAC 48 VAC input FRA French 00 None HAC 100 240 VAC GER German PLF Relay open in alarm IPF Relay closed in alarm 16 amps 25 amps 40 amps 50 amps PDS1 PDS Heater Break Detect PDS2 PDS Current Monitoring 2 Voltage i l 1 PDS not available with PLF IPF uses the same 120V 120 volts two wires to control the switching of the TE10S and microswitch 240V 240 volts to feedback load status MSFU Fuse with 480V 480 volts microswitch 500V 500 volts PDS Heater Break Detect will transmit the power NONE No fuse FUSE Fuse without demand signal to a TE10S typically from a 2200 Series controller and read back a heater break alarm Similarly PDS Current Monitoring will transmit the power demand signal to a TE10S and read back load current open and short circuit alarms High speed fuses are not recommended for SWIR loads Please note that replacement fuses are marked with a hig
3. STRIA Vienna Eurotherm GmbH T 43 1 7987601 F 43 1 7987605 E info at eurotherm com BELGIUM amp LUXEMBOURG Moha Eurotherm S A N V T 32 85 274080 F 32 85 274081 E info be eurotherm com BRAZIL Campinas SP Eurotherm Ltda T 5519 3707 5333 F 5519 3707 5345 E info br eurotherm com DENMARK Copenhagen Eurotherm Danmark AS T 45 70 234670 F 45 70 234660 E info dk eurotherm com FINLAND Abo Eurotherm Finland T 358 22506030 F 358 22503201 E info fi eurotherm com Copyright Eurotherm Limited 2007 FRANCE Lyon Eurotherm Automation SA T 33 478 664500 F 33 478 352490 E info fr eurotherm com GERMANY Limburg Eurotherm Deutschland GmbH T 49 6431 2980 F 49 6431 298119 E info de eurotherm com HONG KONG amp CHINA Eurotherm Limited North Point T 85 2 28733826 F 85 2 28700148 E info hAk eurotherm com Guangzhou Office T 86 20 8755 5099 F 86 20 8755 5831 E info cn eurotherm com Beijing Office T 86 10 6567 8506 F 86 10 6567 8509 E info cn eurotherm com Shanghai Office T 86 21 6145 1188 F 86 21 6145 1187 E info cn eurotherm com INDIA Chennai Eurotherm India Limited T 91 44 24961129 F 91 44 24961831 E info in eurotherm com IRELAND Dublin Eurotherm Ireland Limited T 353 1 4691800 F 353 1 4691300 E info ie eurotherm com ITALY Como Eurotherm S r l T 39 31 975111 F 39 31 977512 E info it eurother
4. bled unit from Eurotherm In short it gives you a well designed tested and compact solution The TE10S is assembled in an ISO9001 2000 registered factory follows international safety regulations and comes with a 2 year warranty The alternative would be to take a solid state device heatsink thermal transfer compound load and control terminals protection covers mounting hardware design regulations and then find the labour to put them all together Self assembled installations tend to use more panel space whether they are mounted directly on the cubicle metal work or on oversized heatsinks Detailed thermal analysis allows Eurotherm to supply the most compact unit for a given current Tough enough for infrared applications The TE10S uses two thyristors so it can withstand fast voltage and current changes 500V us and 100A us and momentary over current at least 400A for 10ms The TE10S is tough enough to handle the current surges that arise when you burst fire short wave infrared elements Simple wiring for single and three phase loads No wiring for electronics supply self powered Can be used for single phase loads 1 x TE10S three phase loads 3 x TE10S firing independently CE marking TE10S Units are CE marked to show that they meet the essential requirements of the European Low Voltage Directive No exposed parts are at a dangerous voltage Eurotherm certificates that the TE10S units have successfully passed the EMC
5. her current rating than the thyristors This allows correct operation at elevated temperatures and does not imply that higher current is permissible SPARE FUSE AND HOLDER SPARE FUSE Current rating Fuse and holder Fuse and Holder Current rating Fuse rating Fuse Trip with amps assembly with Microswitch amps amps Indicator 16 FU1038 16A 00 MSFU1451 16A CH260024 CS176513U020 FU1038 25A 00 MSFU1451 25A CH260034 CS176513U032 40 FU1451 40A 00 MSFU1451 40A CH330054 CS176513U050 50 FU2258 50A 00 MSFU2258 50A CS173087U063 CS176461U063 Fuse holder dimensions Current derating Iy Nominal current of TE10S at 45 C IN 50A In 40A ww v V E E oO oa Dimensions Fuse holder mm FU1038 FU1451 FU2258 35 40 45 50 55 60 Height H 81 95 124 T C Ambient temperature Width L 17 5 26 35 Depth P 68 86 90 a 2 4 b 7 5 7 5 C 38 45 54 d 36 5 40 5 42 Eurotherm International sales and service Understanding and providing local support is a key part of Eurotherm s business Complementing worldwide Eurotherm offices are a whole range of partners and a comprehensive technical support team to ensure you get a service you will want to go back to AUSTRALIA Sydney Eurotherm Pty Ltd T 61 2 9838 0099 F 61 2 9838 9288 E info au eurotherm com AU
6. m com KOREA Seoul Eurotherm Korea Limited T 82 31 2738507 F 82 31 2738508 E info kr eurotherm com NETHERLANDS Alphen a d Rijn Eurotherm B V T 31 172 411752 F 31 172 417260 E info nl eurotherm com NORWAY Oslo Eurotherm A S T 47 67 592170 F 47 67 118301 E info no eurotherm com POLAND Katowice Invensys Eurotherm Sp z 0 0 T 48 32 2185100 F 48 32 2177171 E info pl eurotherm com SPAIN Madrid Eurotherm Espana SA T 34 91 6616001 F 34 91 6619093 E info es eurotherm com SWEDEN Malmo Eurotherm AB T 46 40 384500 F 46 40 384545 E info se eurotherm com SWITZERLAND Wollerau Eurotherm Produkte Schweiz AG T 41 44 7871040 F 41 44 7871044 E info ch eurotherm com UNITED KINGDOM Worthing Eurotherm Limited T 44 1903 268500 F 44 1903 265982 E info uk eurotherm com www eurotherm co uk U S A Leesburg VA Eurotherm Inc T 1 703 443 0000 F 1 703 669 1300 E info us eurotherm com www eurotherm com ED53 Invensys Eurotherm the Eurotherm logo Chessell EurothermSuite Mini8 Eycon Eyris and Wonderware are trademarks of Invensys plc its subsidiaries and affiliates All other brands may be trademarks of their respective owners All rights are strictly reserved No part of this document may be reproduced modified or transmitted in any form by any means nor may it be stored in a retrieval system other than for the purpose to act as an aid in opera
7. oad 1 element in 6 for single phase load 16A 115H x 35W x 93D 53W with PLF IPF 25A 115H x 53W x 93D 70W with PLF IPF 40A 115H x 88W x 93D 105W with PLF IPF 50A 115H x 105W x 93D 123W with PLF IPF Vertical on DIN rail 10mm for full current operation 8mm copper bars Cable sizes 1 5 to 16mm Tightening torque 1 2Nm Cable size 0 5 to 1 5mm Terminals are removable for easy maintenance 16A 320g 25A 500g 40A 770g 50A 880g Environmental Humidity Enclosure protection Isolation Electrical protection Leakage current Storage temperature Cooling Operating temperature Safety standards Atmospheres European directives Electromagnetic compatibility Immunity test standards Emission test standard Safety CE marking 5 to 95 non condensing IP20 IEC 529 All distances comply with IEC 644 Control signals isolated from power tested to 3600Vac Isolation to earth tested to 2000Vac RC snubber network External high speed fuse to be ordered separately Less than 30mA 10 C to 70 C Natural convection 0 C to 45 C up to 60 with derating EN61010 installation category 3 voltage transients must not exceed 4 0KV Electrically conductive pollution must be excluded from the cabinet in which this controller is mounted This product is not suitable for use above 2000m or in corrosive or explosive atmospheres without further protection EN61000 4 EN61000 4 4 PrE
8. tests and enable the system which incorporates them to comply with the EMC Directive as far as the TE10S is concerned An EMC installation guide part no HA025464 is available on request SPECIFICATION Current Voltage Supply frequency Load Load type Single phase connection Three phase connection Firing mode Input Voltage Current Option Partial load failure detection Discrimination Installation Dimensions mm Mounting Inter unit spacing Internal bus bar Power terminals Control terminals Weight 16A 25A 40A and 50A at 45 C Under certain conditions e g lower ambient temperature these units may be run at slightly higher currents Consult your local Eurotherm engineer 48 to 240 Vac 10 15 or 96 to 500 Vac 10 15 47 to 63 Hz Constant resistance or shortwave infrared elements Line to line or line to neutral Three wire star or delta two units control two limbs of the load Four wire star with neutral or six wire open delta three units together Logic firing ON OFF with zero voltage switching Polarity insensitive and can be crossed Command signal indication by green LED LGC 8 to 32Vdc ON gt 8V OFF lt 2V LAC 32 to 48Vac ON gt 30V OFF lt 5V HAC 100 to 240Vac ON gt 85V OFF lt 10V LGC 9mA dc self limiting ON gt 9mA OFF lt 0 5mA Detects an increase in load impedance due to failure or disconnection of part of the heating l
9. ting the equipment to which the document relates without the prior written permission of Eurotherm limited Eurotherm Limited pursues a policy of continuous development and product improvement The specifications in this document may therefore be changed without notice The information in this document is given in good faith but is intended for guidance only Eurotherm Limited will accept no responsibility for any losses arising from errors in this document Part No HA023806 Issue 5 TE10S Specification sheet Printed in England 08 07

Download Pdf Manuals

image

Related Search

Related Contents

Ewent EW3201 mice  Samsung IMPRESORA MULTIFUNCION LASER MONOCROMO SCX-4825FN Manual de Usuario  [ 富士メディカルドライレーザーイメージャ DRYPIX 6000 ] ≫PDF  Installation Manual - Niagara Pool & Spa    Lumière sur les réseaux sociaux - Animation des  CRIOSCÓPIO - PZL Tecnologia  レンタルサービス条項 - 横河レンタ・リース  pSOS System Concepts    