1. rientalert www orientalerf com V MUL 007 C AO Smoke Alarm User s Manual Please read and save this manual PHOTOELECTRIC SMOKE ALARM MODEL VST S588 Class Il Apparatus A EN 50130 4 EN61000 6 3 T V EN 14604 EN 14604 Photoelectric smoke alarms are generally more effective at detecting smoldering fires which smolder for hours before bursting into flame Sources of these fires may include cigarettes burning in couches or bedding MAIN FEATURES gt DC operated photoelectric type smoke alarm gt Photoelectric sensor for slow smoldering fires gt Self Test button gt Non radioactive technology for environmental friendly gt High and stable sensitivity gt Quick fix mounting bracket for easy installation gt Fitting and battery tamper resist feature gt LED operation indicator gt Extra loud alarm sound over 85 dB gt Low battery and battery missing warning indicator gt Auto reset when smoke clears SPECIFICATION gt Model Number VST S588 gt Detection Type Photoelectric Chamber gt Power Source 9V DC Battery gt Standby Current 15uA max gt Alarm Current 30mA max gt Alarm Sound Level 85 Decibels at 3 meters gt Operation Temperature 5 Cto 45 C gt Ambient Humidity 10 90 J gt Sensitivity to Smoke 3 0 6 0 Obs m gt Compact size 110mm diameter gt IMPORTANT SAFETY INFORMATION 1 This smoke alarm requires constant working 9 volt battery to opera
2. 7 Push test button to test smoke alarm See TESTING THE SMOKE ALARM OPERATING YOUR SMOKE ALARM Once the smoke alarm has been installed A RED indicator light LED should flash approximately once a minute to indicate the battery is healthy and the unit is operating properly If smoke is detected the unit will emit a load pulsating alarm and a RED indicator light LED will be flashing quickly until the air is clear TESTING THE SMOKE ALARM Se WS Test 1 Test each smoke alarm to be sure it is installed correctly oy Button and operating properly y f gt N 2 The push to test button accurately tests functions Do not O f i use an open flame to test this smoke alarm You may WN ignite and damage the smoke alarm or your home l 3 Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days 4 Stand at arm s length from the smoke alarm when testing TEST ALL SMOKE ALARMS WEEKLY BY DOING THE FOLLOWING STEPS 1 Firmly push the TEST button and the smoke alarm will sound a loud beep The alarm will stop sounding after releasing the TEST button 2 If smoke alarm does not sound please retest the smoke alarm DANGER ff the alarm sounds and smoke alarm is not being tested the smoke alarm is sensing smoke THE SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION MAINTENANCE AND CLEANING In addition to weekly testing this smoke alar
3. The alarm sound is loud in order to alert individuals to a potential danger However there may be limiting circumstances where a household member may not hear the alarm 1 e outdoor or indoor noise sound sleepers drug or alcohol usage the hard of hearing etc If you suspect that this smoke alarm may not alert a household member install and maintain specialty smoke alarms Household member must hear the alarm s warning sound and quickly respond to it to reduce the risk of damage injury or death that may result from fire If a household member is hearing impaired install special smoke alarms with lights or vibrating devices to alert occupants 8 Smoke alarms can only sound their alarms when they detect smoke Smoke alarms detect combustion particles in the air They do not sense heat flame or gas This smoke alarm is designed to give audible warning of a developing fire However many fires are fast burning explosive or intentional Others are caused by carelessness or safety hazards Smoke may not reach the smoke alarm QUICKLY ENOUGH to ensure safe escape 9 Smoke alarms have limitations This smoke alarm is not foolproof and is not warranted to protect lives or property from fire Smoke alarms are not a substitute for insurance Homeowners and renters are responsible for insuring their own lives and property In addition it is possible for the smoke alarm to fail at any time For this reason you must test the smoke alarm weekly and rep
4. d blow smoke away from the detector interrupting its alarm 4 In rooms where temperatures may fall below 5 C or rise above 45 C 5 In extremely dusty dirty or insect infested areas where loose particles interfere with smoke alarm operation WARNING Incorrect orientation will result in a decrease in operational effectiveness HOW TO INSTALL THIS SMOKE ALARM m Mounting Slots eo N fi Mounting Bracke f E Katt EOL ounting Bracket iU g i AA F ai Lie ME A GZ i 2 ae Screw A se s 9V Battery A f S Ti K H wy i 7a 7 y Y L p Z N WARNING Smoke alarm installation must be in accordance with the requirements of any national local codes that may apply 1 Remove the mounting plate by turning it counterclockwise at the back of the smoke alarm To later engage tamper resist feature twist out and set aside one of the pins molded into plate Both pins are exactly the same 2 Install the mounting plate to ceiling or wall with mounting screws 3 Lift open battery pocket door 4 Connect new 9 volt battery to battery connector inside battery pocket Be sure battery is securely connected Red LED may blink briefly when battery is installed 5 Close battery pocket door snapping it into place 6 Position smoke alarm to mounting plate and turn clockwise to lock into place To engage tamper resist feature insert pin into notch on edge of smoke alarm after alarm is properly positioned in base SEE
5. ding as quickly as possible Touch doors to feel if they are hot before opening them Use an alternate exit if necessary Crawl along the floor and do not stop to collect anything 3 Meet at a pre arranged meeting place outside the building 4 Call the fire department from outside the building 5 Do not go back inside a burning building Wait for the fire department to arrive These guidelines will assist you in the event of a fire However to reduce the chance that fires will start practice fire safety rules and prevent hazardous situations TROUBLESHOOTING Z AWARNING DO NOT disconnect battery to quiet an unwanted alarm This will remove your protection Fan the air or open a window to remove smoke or dust Smoke alarm does not sound when 1 Remove smoke alarm from mounting plate and check that battery is tested properly attached to connector NOTE Push test button for at least 2 Clean smoke alarm five seconds while testing Smoke alarm beeps about once a Replace battery See battery replacement in the maintenance and minute cleaning section Smoke alarm sound unwanted Clean smoke alarm See cleaning in the maintenance and cleaning alarms intermittently or when section residents are cooking taking 2 Move smoke alarm to a new location See SMOKE ALARM showers etc PLACEMENT The alarm sounds different than The alarm is operating correctly This alarm features the I m used to It starts and stops internati
6. ew Leader 6F22 Gold Peak 1604 Eveready 522 1222 Golden Power G6F22 Golden Power GL6F22A or equivalent quality models available from electrical or hardware stores CLEANING Clean the smoke alarm at least once a month to remove dust dirt or debris Using the soft brush or wand attachment to a vacuum cleaner vacuum all sides and cover of smoke alarm Be sure all the vents are free of debris If necessary use a damp cloth to clean smoke alarm cover IMPORTANT Do not attempt to remove the cover to clean inside the smoke alarm This will void your warranty PRACTICE FIRE SAFETY If the smoke alarm sounds its alarm horn and you have not pushed the test button it is warning of a dangerous situation Your immediate response is necessary To prepare for such occurrences develop family escape plans discuss them with all household members and practice them regularly 1 Expose everyone to the sound of a smoke alarm and explain what the sound means 2 Determine two exits from each room and an escape route to the outside from each exit 3 Teach all household members to touch the door and use an alternate exit if the door is hot Instruct them not to open the door if the door is hot 4 Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases 5 Determine a safe meeting place for all members outside the building WHAT TO DO IN CASE OF FIRE 1 Do not panic stay calm 2 Leave the buil
7. lace every 10 years Note For best protection we recommend that you install a smoke alarm in every room RECOMMENDED LOCATIONS FOR SMOKE ALARMS Installing Smoke Alarms in Single Family Residences Minimum coverage is one unit on every floor in every sleeping area or in every bedroom For additional coverage Orientalert recommends you install units in all rooms halls storage areas and finished attics where temperatures normally remain between 5 C and 45 C More specifically install Smoke Alarms On every level of your home including finished attics Inside every bedroom especially if people sleep with doors closed In the hall near every sleeping area If your home has multiple sleeping areas install a unit in each If a hall is over 12 meters 40feet long install an alarm at each end At the top of the first to second floor stairway IMPORTANT Specific requirements for Smoke Alarm installation vary from state to state Check with your local Fire Brigade for current requirements in your area See Recommended Locations for Smoke Alarm Diagram following BEDROOM HALL BEDROOM LIVING ROOM a KITCHEN h S atte BASEMENT MULTI STORY RESIDENCE BEDROOM O A O KITCHEN DINING ROOM O O BEDROOM LIVING ROOM SINGLE STORY RESIDENCE APARTMENT MOBILE HOME KEY Minimum required smoke alarm locations ORecommended additional smoke alarm locations A Smoke alarms with hush features recommended f
8. m requires yearly battery replacement and periodic cleaning to remove dust dirt and debris BATTERY REPLACEMENT Replace battery at least once a year or immediately when the low battery signal sounds once a minute Batteries should be replaced regularly as necessary WARNING Do not use any other type of battery except as specified in this manual Do not use rechargeable batteries A CAUTION If the battery is incorrectly replaced the smoke alarm will not operate and may cause damage Please use high quality batteries to ensure long term performance 1 Turn smoke alarm counterclockwise to detach it from the mounting plate 2 Gently pull down smoke alarm 3 Remove battery from the compartment 4 Insert a new 9 volt battery to connector NOTE POLARITY OF CONNECTIONS Ensure the metal tab is fully depressed when the battery has been fitted 5 Using the Push to Test button test the smoke alarm to verify 9V DC battery See TESTING THE SMOKE ALARM 6 Reattach the smoke alarm to the mounting plate by turning smoke alarm clockwise until it snaps into place Insert the two tamperproof tabs back into the notch on edge of smoke alarm after alarm is properly positioned in base 7 Test the smoke alarm using Test button See TESTING THE SMOKE ALARM CHOOSING A REPLACEMENT BATTERY The unit requires one standard 9V battery The following batteries are acceptable as replacements Golden Power 6F22 Megaton 6F22 N
9. onally recognized horn signal for evacuation The alarm sound pattern is 3 short beeps followed by a 2 second pause and then repeats Manufacturer Xiamen Vs Top Electronics Co Ltd 2nd floor No 107 Xiaguang Road Xinyang Industrial District Haicang Xiamen China Tel 0086 592 6017700 Fax 0086 592 6017711 E mail info vs top com Website www orientalert com
10. or additional protection IMPORTANT SMOKE ALARM PLACEMENT AND EXCEPTION INFORMATION 1 Install a smoke alarm as close to the center of the ceiling as possible If this is not practical mount no closer than 4 inches from a wall or corner Also if local codes allow install smoke alarms on walls between 4 and 12 inches from ceiling wall intersections 2 Install a minimum of two smoke alarms in every home no matter how small the home 3 Install a smoke alarm in each room that is divided by a partial wall either coming down from the ceiling at least 8 inches or coming up from the floor 4 Install a smoke alarm in lived in attics or attics which house electrical equipment like furnaces air conditioners or heaters 10CM 4 DO NOT INSTALL SMOKE ALARMS no auen Yi ff f yy Uy o F 7 s r PAS z zo BESTHERE NEVERHERE WHV 57 ANYWHERE 7 n A IN THIS AREA Uj 8 ACCEPTABLE HERE Y 3 E fi 0 9M 3ft 0 9M 3ft A j SIDEWALL HORIZONTAL DISTANCE Wye FROM PEAK 1 Near appliances or areas where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarm with unwanted alarm control for this areas 2 In areas with high humidity like bathrooms or areas near dishwashers or washing machines Install at least 10 feet away from these areas 3 Near air returns or heating and cooling supply vents Install at least 3 feet away from these areas The air coul
11. te properly This smoke alarm WILL NOT work if DC power is not connected or has failed or been interrupted for any reason AND the battery is removed drained or improperly connected DO NOT use any other kind of battery except as specified DO NOT connect this smoke alarm to any other type of smoke alarm or auxiliary device It is designed as a stand alone unit 2 The Test button accurately tests all smoke alarm functions Do not use any other test method Test smoke alarm weekly to ensure proper operation 3 DO NOT remove or disconnect battery to quiet unwanted alarms This will remove your protection Open windows or fan the air around smoke alarm to silence it 4 Observe and follow all local and national electrical and building codes for installation 5 This smoke alarm is designed to be used inside a single room only In multi room buildings each individual living unit should have its own smoke alarms Do not install in non residential buildings And this smoke alarm is not a substitute for a complete alarm system 6 Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire except in the area or room in which it is installed 7 Smoke alarms may not alert every household member every time