Home
Temperature Sensor
Contents
1. UP or DOWN to select the minute 3 Release all buttons after setting the minute Upper Temperature Limit When the actual temperature is above the upper temperature limit the temperature sensor will send a signal to the control panel To set the upper temperature limit 1 Press and hold the HI button 2 While holding on to the HI button press UP or DOWN to select the upper temperature limit 3 Release all buttons after setting the upper temperature limit Lower Temperature Limit When the actual temperature is below the lower temperature limit the temperature sensor will send a signal to the control panel To set the lower temperature limit 1 Press and hold the LO button 2 While holding on to the LO button press UP or DOWN to select the lower temperature limit 3 Release all buttons after setting the lower temperature limit Set the temperature unit Fahrenheit Celsius The temperature sensor can operate and display temperature in Fahrenheit or Celsius To select the desire unit open the back cover you will see a jumper connector for C F as shown below To select Fahrenheit place a jumper on this C F connector To select Celsius remove the jumper from this connector Remove back cover Note The temperature sensor can monitor the temperature within this range 157 F 69 C to 3 F 19 C 2 PROGRAMMING CONT
2. doesn t show up on the display External Temperature If you would like to monitor the external temperature i e outdoor tem perature you may use the external measuring probe Plug in the external testing probe as show on the back of the sensor Ensure to select the EXT on the front panel If no external measuring probe is plugged in but EXT is selected the display will not show any temperature External Dry Contact Normal Open External Dry Contact You may connect the temperature sensor to other devices by the N O dry contact Simply plug in the cable into the socket on the back of the sensor as shown Connect the other end of the cable to the device that you would like to connect to When the temperature is above or below the preset limits the contact will be closed momentary therefore activating the connected device External Temperature The maximum ratings of the N O relay contact is 2A 24V DC therefore do not connect an external device which exceeds this rating The relay contact is not designed for AC connection DO NOT CONNECT AC DEVICE TO THIS N O CONTACT 7 SENSOR FAILURE OR LOW BATTERY Sensor Failure Only avaliable for AAA The control panel constantly monitors its sensors if the control panel fails to communicate with any sensors it will notify the user by 1 The zone LED of the failed sensor will be on steadily 2 Voice announcement zone X sensor Y failure will be pla
3. Compatibility Jumper Refer to the following table to setup the sensor to work with different Skylink s Security System or Emergency Dialer To select open the back cover you will see a jumper connector for J2 as shown below Use a paper clip to remove the jumper connector Remove back cover i p Jumper J2 setting Keep the connector in default post AM 001 ML 001 AD 105 SC 001 AA 433 AD 433S MS 2001 LF a ED 100 3 Reposition connector to 2 posts You have now programmed the temperature sensor and you can mount the sensor to the desired location 3 LEARN SENSOR TO AAA CONTROL PANEL In order for the sensor to communicate with the control panel properly the sensor must be programmed to the control panel Follow the brief instructions below or refer to the detail instructions from the AAA User s Instructions to program the sensor to the control panel Before proceeding please remove the battery isolator from the sensor Se PROG Enter Program Enter master 3 beeps for valid MPIN ming mode password to password 1 long programming beep for invalid mode password Select learn sensor programming After 3 is entered some zone LEDs will flash once or twice some will be off The zone LEDs represent whether that zone is already occupied by another sensor See Table A below Refer to the dia After you have gram below to selected the zon
4. Temperature Sensor Model TS 101A 1 INTRODUCTION The Temperature Sensor is designed to monitor the temperature of a specific area whether that is the indoor temperature or outdoor temperature It works in conjunction with the AAA Control Panel as well as other Skylink s alarm system such as SC 001 or AD 433S etc When the actual temperature exceeds the preset limit the control panel will either alert you or alarm will be triggered In this package you should find the temperature sensor 2 lithium batteries an external measuring probe for measuring outdoor temperature and mounting accessories bi s G p e n External measurin Temperature ah probe g Sensor 5 X 20 screws External Batteries inside dry contact cable Please follow the instructions below to set up the temperature sensor 2 PROGRAMMING There are several things you need to program 1 Clock 2 Upper temperature limit 3 Lower temperature limit 4 Set the temperature unit Fahrenheit Celsius 5 Compatibility jumper J2 Clock The current time will be displayed when the HOUR or MIN button is pressed To set the hour 1 Press and hold the HOUR button 2 While holding on to the HOUR button press UP or DOWN to select the hour 3 Release all buttons after setting the hour To set the minute 1 Press and hold the MIN button 2 While holding on to the MIN button press
5. This equipment conforms to the essential requirement of the Directive 1999 5 EC of the European Parliament and of the Council 10 WARRANTY If within one year from date of purchase this product should become defective except battery due to faulty workmanship or materials it will be repaired or replaced without charge Proof of purchase and a Return Authorization are required 11 CUSTOMER SERVICE If you would like to order Skylink s products or have difficulty getting them to work or download latest information and user manual please 1 visit our FAQ section at www skylinkhome com or 2 email us at support skylinkhome com or 3 call our toll free at 1 800 304 1187 from Monday to Friday 9 am to 5 pm EST Fax 800 286 1320 FE CE Z CUSTOMER SERVICE 17 Sheard Avenue Brampton Ontario Canada L6Y 1J3 Email support skylinkhome com http www skylinkhome com P N 101Z2468 002 US Patent 6243000B1 2008 SKYLINK GROUP
6. e select the sensor that zone LED will location which be on includes the zone and sensor number Select sensor location 3 lt 5 0 to 9 2 4 button on the trol Panel which numbers you have will be stored selected temperature 3g Activate the Activate sensor Once the sensor You will hear Zone X sensor by is activated the Sensor Y Accepted pressing the signal will be trans where X and Y are red Panic mitted to the Con the zone and sensor This row Buttons for Sensor 1 Zone LED Flash once This row Buttons for Sensor 2 Zone LED AM 001 Flash twice Note Each location is allowed to learn one sensor only Learning a sensor to a location will clear the memory of the sensor previously learnt Zone 4 Button 4 Button 9 3 LEARN SENSOR TO AAA CONTROL PANEL CONT ZONE LED Off Flashes once DESCRIPTION Zone is not occupied by any sensor This zone is occupied by sensor 1 Flashes twice This zone is occupied by sensor 2 Flashes once then twice This zone is occupied by sensors 1 and 2 Table A Zone LED status for learning sensors 4 LEARN SENSOR TO SC 001 AA 433 AND AD 433S To program the temperature sensor to other Skylink s receivers such as SC 001 AA 433 AD 433S etc please follow the instructions below 1 Activate the programming mode of your Skylink s receiver refer to the owner s instructions of y
7. ons 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment dose cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 9 CE Declaration of Conformity
8. our Skylink s receiver 2 To transmit the signal from the temperature sensor press the red button on the temperature sensor The red button is for programming purpose only 3 Follow the rest of the instructions from the Skylink s receiver to complete the programming procedure 5 INSTALLATION The temperature sensor should be mounted onto the wall by 2 screws Follow the procedures below 1 Use a template to mark the location for the 2 screws correctly 2 Tighten the screws onto the wall half way 3 Hang the temperature sensor onto the 2 screws Note The temperature sensor is not designed to be used outdoor it must be installed indoor To monitor outdoor temperature an external measuring probe can be used while the temperature sensor is installed indoor 6 OPERATION The temperature sensor must be enabled in order to monitor the temperature and communicate with the control panel You may enable the upper tempera ture limit only or lower temperature limit only or both To enable the upper or lower temperature limit simply press HI or LO If the display shows HI that means the upper temperature limit is enabled If the display shows LO that means the lower temperature limit is enabled If the display shows both HI and LO that means both upper and lower tempera ture limits are enabled To disable the temperature limits simply press the same button again until the HI or LO
9. yed When sensor failure occurs try the following 1 Check if the sensor is located at where it should be and whether there is any physical damage to the sensor 2 If the failed sensor is not physically damaged try to activate the sensor and see if the control panel reacts to such activation 3 If not try to remove the sensor from its location and bring it closer to control panel and activate the sensor It is possible that the sensor is installed too far from the control panel and it cannot establish a steady communication with the control panel If this is the case please install the sensor closer to the control panel 7 SENSOR FAILURE OR LOW BATTERY CONT Sensor Low Battery Only available for AAA Two CR 2032 lithium batteries are used to operate the temperature sensor When the sensor is in low battery condition the low battery LED indicator will flash Temperature sensor will also send a wireless low battery signal to the AAA Control Panel When you see the low battery indication replace the batteries following the procedures below 1 Remove the screw on the back of the temperature sensor as shown 2 Rotate the battery compartment the batteries can be removed 3 Place the new batteries into the compartment pay attention on the polarity as indicated on the diagram 4 Tighten the screw 8 FCC This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditi
Download Pdf Manuals
Related Search
Related Contents
9 7 5 3 2 - Electronic Arts Linksys WET54GS5 User's Manual Philips Ecomoods Wall light 33219/48/16 Fahrpulte & Funk MX31 - Krois Nokia 6670 - Microsoft Fleem® Valencia Bio-Ethanol 2.0 Instructions for use none IF-BSTD-100 Installation Guide Form #4193 SafeTI Compiler Qualification Kit (Rev. D) Copyright © All rights reserved.