Contents
1. 9 Acquisition delayed Acquisition start delayed from the scheduled time 10 Stand by Datalogger is set in sleep mode to optimize consumption 11 Switched on Datalogger has been switched on 12 Wake up Datalogger woke up from the low power mode to start a scheduled activity 13 Acquisition set Datalogger once an acquisition cycle has ended sets the next one After in the column are displayed the date and time of next acquisition 14 Acquisition wait Datalogger after setting the next Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document industries Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved acquisition waits to execute it 15 _ Script started Start executing Script A script includes an activity that could be executed by Datalogger e g acquisition control updates etc 16 Script ended Currently not used 17 Task active Currently not used 18 Task inactive Currently not used 19 Currently not used 20 email successfully sent The email has been successfully sent to the configured addresses 21 SMTP server timeout error The SMTP outgoing mail server took too much time to answer
2. Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document i fr co gt LT Rev 2 del 2014 07 11 industries Copyright NEXT INDUSTRIES S r L All right reserved 82 COMX task stop Currently not used 83 Multiplexer inizialization Currently not used 84 Multiplexer de inizialization Currently not used 85 Mailbox allocation failed Task communication error 86 Internal ADC timeout ADC internal error 87 web folder updated Web pages update was successful 88 _ Restore folder updated The restore folder update was successful 89 NewFw hex updated The NewFw hex file has been correctly copied within the Firmware folder in the Datalogger SD card 90 _ Error during web folder copy Web pages update was unsuccessful 91 Error during restore folder copy The restore folder update was unsuccessful 92 Error during NewFw hex file copy An error occurred during the NewFw hex file copy within the Firmware folder onthe Datalogger SD card 93 Bootloader update failed The firmware update through bootloader mode was unsuccessful 94 OMNIAlog reboot Datalogger has been restarted from the user or after an operation e g data download that expects a restart
3. an impulse on digital input IN1 occurred 50 Extemporary Acquisition alarm Digital An extemporary acquisition not Input 2 programmed due to an impulse on digital input IN2 occurred Event Codes The following codes can be displayed in the web page Data Monitor Events and are exported in the file ELog_dd_mm_yy csv NOTE when OMNIAlog or miniOMNIAlog are not specified we refer to them as Datalogger Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document industries Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved LEGENDE Light Blue solo per OMNIAlog Orange solo per miniOMNIAlog Code Description Note 0 Login executed Login executed from web 1 Logout executed Logout executed from web 2 Configuration Edited Currently not used 3 Send measures on FTP Attempt to send Measure Log file through FTP 4 Send events on FTP Currently not used 5 Send alarms on FTP Attempt to send Alarms Log file through FTP log 6 Login via console Currently not used 7 Acquisition started Datalogger started the acquisition cycle 8 __ Acquisition ended Datalogger ended the acquisition cycle
4. error during the firmware upload 46 BackUp files access error Backup firmware access error 47 Restore files access error Restore firmware access error 48 BackUp copy error Backup firmware copy error 49 New firmware corrupt The uploading firmware is corrupted and therefore useless 50 BackUp firmware currupt The back up firmware on Datalogger is corrupted and therefore useless 51 Restore firmware currupt Currently not used 52 FTP Authentication error Error in the server FTP access credentials 53 FTP File access not possible Impossible to create file on server verify the path of the destination folder 54 FTP File not found The requested file is not on the FTP server the file with the firmware version for the updates check has not been found on the server 55 FTP Generic error FTP generic error 56 FTP File sending OK The file has been correctly sent from Datalogger to FTP server 57 FTP Timeout server FTP server does not answer 58 FTP File transfert not possible Error during the connection with FTP server 59 FTP Re transmission Overflow queue The re transmission queue is full 60 ISMS sent ok The SMS has been correctly sent from Datalogger Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this
5. or is not available 22 email sending error It was not possible to send the email to the configured addresses 23 DNS resolution error The server name resolution gave a negative outcome it was impossible to reach the server 24 email connection error It s not possible to connect to the email server probably a firewall prevents the connection or the server is not available 25 mailbox full Datalogger internal email buffer is full Some emails had been lost since the server is not achievable 26 DNS resolution ok The server name resolution gave a positive outcome it was possible to reach the server 27 Loading error Script The file script is not found on OMNIAlog 28 Aborted Script The script ended prematurely the Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document industries Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved execution 29 OMNIAlog in STOP mode Datalogger has been set from the user in STOP mode 30 OMNIAlog in CONFIGURATION mode Datalogger has been set from the user in CONFIGURATION mode 31 OMNIAlog in ACQUISITION mode Datalogger has been set from the user in ACQUISITION mode 32 Syntax error Syn
6. there is a communication error with a MODBUS device on RS485bus or on electronics dedicated to vibrating wires 9 eALR_EVT_HW_DL Currently not used 10 eALR_EVT_CONFIGURATION This event is created when there is a setting error in a sensor that has to be acquired e g sensor is not enabled 11 eALR_EVT_HW_BASE Currently not used 12 eALR_EVT_HW_ADC ADC communication error 13 eALR_EVT_DRDY ERROR ADC answer error Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved 14 eALR_EVT_DAC_ERROR DAC communication error 15 eALR_EVT_MEAS_DRIVER_ERROR Measurement driver communication error relay 16 eALR_EVT_MEAS_SEQ_ERROR SPI measurement communication error 17 eALR_EVT_MUX_DRIVER_ERROR Multiplexer relay communication error 18 eALR_EVT_MUX_SEQ_ERROR SPI multiplexer communication error 19 eALR_EVT_CURR_POLY_FILE_ERROR Current calibration file not found 20 eALR_EVT_VREF_POLY_FILE_ERROR Currently not used 21 eALR_EVT_OVERCURRENT_ERROR Overcurrent sensors power supply 22 eALR_EVT_VW_ERROR Vibrating wire sensors reading error co
7. 7 Disconnection error Modem does not disconnect 38 Inbound connection error Modem can t accept an input connection 39 Humidity alarm Low Threshold OMNIAlog humidity value is lower than minimum threshold 40 Humidity alarm High Threshold OMNIAlog humidity value is higher than minimum threshold 41 Temperature alarm Low Threshold Datalogger temperature value is lower than minimum threshold 42 Temperature alarm High Threshold Datalogger temperature value is higher than minimum threshold 43 Power Supply alarm Low Threshold Datalogger power supply is lower than minimum threshold 44 Power Supply alarm High Threshold Datalogger power supply is higher than minimum threshold 45 Low space alarm Log measure Log Measure file size exceeds maximum size 46 Low space alarm Log event Log Events file size exceeds maximum size 47 Low space alarm Log alarm Log Alarms file size exceeds maximum size 48 Script syntax error alarm Syntax error in the acquisition script 49 Extemporary Acquisition alarm Digital An extemporary acquisition not Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved Input 1 programmed due to
8. 95 Database update OMNIAlog configuration After a data structure update the old deleted configuration on Datalogger has been deleted to avoid conflicts 96 Update check error OMNIAlog was not able to check on internet for new firmware This is an automatic weekly check 97 Update check executed OMNIAlog successfully checked on Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document MEST industries Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved internet for new firmware This is an automatic weekly check 98 V OUT power supply reset OMNIAlog resets switched on and off the power on V OUT clamp to allow the reset of the communication device connected to OMNIAlog This is an automatic operation performed daily at 00 00 99 Login The user logins Datalogger through the Web pages 100 Logout The user logouts Datalogger through the Web pages 101 Calibration Internal Temperature Sensor The internal microcontroller temperature sensor has been calibrated the calibration button has been pushed 102 External RAM init fail The external RAM is in an incorrect state 103 Meas settings It shows the measure informatio
9. It is impossible to stop miniOMNIAlog E7 It is impossible to test the modem it is not present Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document i Ne gt lt T Rev 2 del 2014 07 11 industries Copyright NEXT INDUSTRIES S r L All right reserved Alarms codes The following codes can be displayed in the web page Data Monitor Alarms and are exported in the file ALog_dd_mm_yy csv NOTE when OMNIAlog or miniOMNIAlog are not specified we refer to them as Datalogger LEGEND Light Blue only for OMNIAlog Orange only for miniOMNIAlog Code Description Note 0 eALR_EVT_NONE This event is displayed in the CSV file on the input B INB when with a datalogger alarm there is no alarm on input B INB 1 eALR_EVT_TH_LOW This event is created when you set the alarm event Low Threshold and the reading of the sensor is less than the threshold set 2 eALR_EVT_TH_HI This event is created when you set the alarm event High Threshold and the reading of the sensor is higher than the threshold set 3 eALR_EVT_TH_LOW_HI This event is created when you set the alarm event High Low Threshold and the reading of the sensor is higher or lower than the threshold set 4 eALR
10. Rev 2 del 2014 07 09 Copyright NEXT INDUSTRIES S r L All right reserved OMNIAIog and mnOMNIAIog CODE LIST Errors Alarms Events Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document i NCe gt lt T Rev 2 del 2014 07 11 industries Copyright NEXT INDUSTRIES S r L All right reserved Error codes OMNIAlog The following error codes are displayed at system startup Code Description SD Card incorrectly formatted Error formatting SD Card SD Card not found Impossible to access Sensors settings file Impossible to access Communication settings file Impossible to access Datalogger settings file Impossible to access Users settings file Impossible to access Energy Savings settings file OlLOINI Ds UySPl wl ni e Impossible to access Alarms settings file miniOMNIAlog The following error codes are displayed on miniOMNIAlog display Code Description EO General Communication or FTP MAIL connection Error It refers to log events on web server E1 USB Drive not found E2 Error in file copy E3 miniOMNIAlog is already in run mode E4 It is impossible to start miniOMNIAlog E5 miniOMNIAlog is already in configuration mode E6
11. _EVT_TH_ DELTA This event is created when you set the alarm event Derivate Threshold and the variation between the previous reading and the current is higher than the Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document n i NCe gt lt T Rev 2 del 2014 07 11 industries Copyright NEXT INDUSTRIES S r L All right reserved threshold set 5 eALR_EVT_TH_LOW_DELTA This event is created when you set the alarm event Derivate Low Threshold and the variation between the previous reading and the current is higher than the threshold set or the reading of the sensor is lower than the lowest threshold set 6 eALR_EVT_TH_HI_ DELTA This event is created when you set the alarm event Derivate High Threshold and the variation between the previous reading and the current is higher than the threshold set or the reading of the sensor is higher than the highest threshold set 7 eALR_EVT_TH LOW_HI DELTA This event is created when you set the alarm event Derivate High Low Threshold and the variation between the previous reading and the current is higher than the threshold set or when the reading of the sensor is higher or lower than the highest or the lowest threshold set 8 eALR_EVT_COMM This event is created when
12. d 113 VW firmware update launched The user has already launched DSC update VW Digital Signal Controller 114 VW firmware update completed DSC update is complete 115 VW firmware update failed Timeout DSC DSC update failed because of the timeout DSC didn t answered 116 VW firmware update failed Verify error DSC update failed the user can t correctly set up the DSC 117 VW firmware update failed Copy file error DSC update failed file not found 118 VW firmware update failed Hex file DSC update failed the file has been corrupted found but is corrupted 119 PC connection established It was established a PC connection through USB only for miniOMNIAlog 120 PC connection closed It was done the PC disconnection through USB only for miniOMNIAlog 121 System warning 1 An incorrect start of oscillator occurred Anyway the system works correctly using the internal oscillator Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved OMNIAIlog alarm threshold The following table shows the different alarm thresholds in OMNIAlog Alarm type Minimum threshold Maximum thresh
13. document industries Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved 61 ISMS sent error There had been a problem in sending the SMS 62 PPP Connection Datalogger tries to start an INTERNET connection through GSM GPRS modem connected to RS 232 63 PPP connection established An INTERNET connection through GSM GPRS modem was established 64 PPP connection closed INTERNET connection closed 65 Modem answer error The modem didn t answer correctly 66 Modem signal level It shows the signal level of the modem 67 No modem signal The modem has no signal 68 Signal level to poor for connection The modem has not enough signal for communication 69 Test modem started Modem test started 70 Log modem info Generic log on modem 71 OMNIAlog configuration Datalogger is set in CONFIGURATION mode through the web 72 OMNIAlog stop Datalogger is set in STOP mode through the web 73 OMNIAlog start Datalogger is started through the web Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document n i Ne gt lt T Rev 2 del 2014 07 11 industries Copyright NEXT INDUSTRIES S r L All right reserved 74 Default Calibration Current Sou
14. mmunication error with dsPIC the microcontroller is not programmed or it is defective 23 eALR_EVT_OVERRANGE_INA_ERROR Input A IN A reading over range 24 eALR_EVT_OVERRANGE_INB_ERROR Input B IN B reading over range 25 eALR_EVT_VW_NO_SENSOR Vibrating wire sensor not found 26 eALR_EVT_VW_NO_TERMISTOR Temperature sensor of a vibrating wire sensor not found 27 eALR_EVT_MODBUS BASE Currently not used 28 eALR_EVT_MODBUS_CRC_ERROR CRC frame MODBUS error 29 eALR_EVT_MODBUS FRAMING ERROR MODBUS frame length error 30 eALR_EVT_MODBUS_PROTOCOL_ERROR MODBUS protocol error 31 eALR_EVT_MODBUS_TIMEOUT MODBUS communication timeout 32 Modem answer error This event created when the modem does not answer to a command Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document industries Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved 33 SIM PIN enabled Currently not used 34 Wrong PIN Currently not used 35 Modem connection error Impossible to establish an INTERNET connection 36 Modem connection configuration error INTERNET connection parameters could be wrong 3
15. n set from the user 104 Mod info It shows Datalogger model 105 Reset to default settings The user resets the Datalogger settings through web Reset default settings button 106 Extemporary Aquisition Test Measure A test reading has been requested from the web Test Measure button 107 Extemporary Aquisition Read Now A prompt acquisition has been requested from the web Acquisition button 108 USB Data download Data have been downloaded through USB pen drive 109 Extemporary Aquisition Digital Input 1 An acquisition due to an impulsive survey TRIGGER on digital input 1 has Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved been executed 110 Extemporary Aquisition Digital Input 2 An acquisition due to an impulse survey TRIGGER on digital input 2 has been executed 111 Vibrating wire search start frequency The standard research for the vibrating adjusted wire failed It was started the research on central frequencies 112 Mail attachment too big The mail attachment was too big and has been droppe
16. old Temperature 20 C 65 C Humidity 10 00 80 00 Power battery 25 00 100 00 Power external 9V 20V up to fw 3 37 17 version 30V from fw 3 38 18 version Log_Measure 10 so 90 of full memory Log_Alarm 100 MB Log_Events 100 MB Internal memory 10 These thresholds are fixed and can t be set from the user miniOMNIAlog alarm threshold The following table shows the different alarm thresholds in miniOMNIAlog Alarm type Minimum threshold Maximum threshold Temperature 20 C 65 C Power battery 8 4V not present Power external 10 5V 14V Log_Measure 10 so 90 of full memory Log_Alarm 100 MB Log_Events 100 MB Internal memory 10 Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved These thresholds are fixed and can t be set from the user Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document
17. rce This event is created when the default calibration file is used It means that the calibration file created by NEXT INDUSTRIES is incorrectly detected from Datalogger 75 Default Calibration Vref This event is created when the default calibration file is used Vref is not calibrated so this message could always be used 76 Default Calibration 10mV This event is created when the calibration file for the 10mV range is used It means that the calibration file created by NEXT INDUSTRIES is incorrectly detected from Datalogger 77 Default Calibration 100mV This event is created when the calibration file for the 100mV range is used It means that the calibration file created by NEXT INDUSTRIES is incorrectly detected from Datalogger 78 Default Calibration 1V This event is created when the calibration file for the 1V range is used It means that the calibration file created by NEXT INDUSTRIES is incorrectly detected from Datalogger 79 Default Calibration 10V This event is created when the calibration file for the 10V range is used It means that the calibration file created by NEXT INDUSTRIES is incorrectly detected from Datalogger 80 Default Calibration 4 20mA This event is created when the calibration file for the 4 20mA range is used It means that the calibration file created by NEXT INDUSTRIES is incorrectly detected from Datalogger 81 COMX task start Currently not used
18. tax error in the script 33 Unbalanced bracket Unbalanced brackets within the script 34 No formula Currently not used 35 Is not a variable procedure Currently not used 36 Expected THEN IF structure error 37 Program too complex The script is too complex to be executed 38 REPEAT IF unbalanced The structure has been created incorrectly Impossible to execute the script 39 Too many variables procedures Too many variables or procedures have been used in the script The available memory is not sufficient 40 Parameter error An invalid argument had been passed to a script function 41 New firmware uploaded ver Firmware update correctly executed It is displayed also the uploaded version 42 Firmware already on board ver The firmware has not been updated because an updated version is already installed on Datalogger 43 BackUp firmware uploaded ver Datalogger restored the back up firmware after a new update failure Document owned by Next Industries Srl which reserves the rights sanctioned by the law Reproductions and partial reproductions of this document can be made only by the issuer All institutions must to destroy the previous revision of this document industries Rev 2 del 2014 07 11 Copyright NEXT INDUSTRIES S r L All right reserved 44 Restore firmware uploaded Currently not used 45 FLASH access error Flash writing
Download Pdf Manuals
Related Search
Related Contents
Tellus 3+ User Guide Robot Adept Cobra 600 Manuel d`instruction inSentry Pro User's Guide User Manual - ISY - Linköping University ViraBind™ AAV Purification Mega Kit Consulta de Expertos OPS/OMS sobre Leishmaniasis Visceral en Samsung Galaxy Tab 4 (7.0, LTE) Lietotāja rokasgrāmata RESOL FlowCon A 48001030*48001030* ! AVERTISSEMENT - Napoleon Products Copyright © All rights reserved.