1.        Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p e  gt   Ortho System    2012 User Manual    3  Select the desired Report template    4  Click Generate report to load it in a separate  window    5  You can explore the report using various  visualization tools in the top toolbar    6  The report can be Exported to a folder in  rtp  format and print it out  if needed     LJ Export  report  5 Print  report  G  i Refresh  Ga   e    CASE    s Ik    ge   Toggle  om E group    Sean date  3 24 2010 2 35 16 PM tree  ld 4   H Navigat  e  around  the  pages  Li Go toa  specific  page  x Close  current  view  Ki Search  for text    ON e Zoom             L   L       Current Page Now 1 Total Page No  2 Zoom Factor 200        Toggle group tree  the displayed Analysis report consists of the two main parts   Views   Configuration section in OrthoAnalyzer  and Analysis  Analysis section   The rest of the  group tree structure specifies the multiple parts of the sections covered here  model  images      Close current view  active when displaying a model image  does not apply to the Main    Report    3Shape A S 3Shape Inc  3Shape Asia 95  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road   DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 
2.       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual       LI    d ch T    Zoom all     Sets the model to the default view  size and position on the  screen leaving its current rotation angle intact     Real scale view   Displays the model on a screen in the real size  A special  scale that appears on a screen helps to manually set the model in the real  size by comparing an actual ruler with the scale on a screen       Axis locked rotation     Locks the rotation to the  l w  Free rotation X  y or Z axes          w  l X axis locked  L   Y axis locked      j   i   Z axis locked       Mouth view   allows you to switch between the two types of cast  visualization     e Open mouth view   Enables detailed analysis of individual items on  the virtual casts with minimal relation to each other    e Closed mouth view   Enables relational occlusion analysis for the  maxillary and the mandibular arches     Show maxilla and Show mandible   Selects either the upper or the lower  cast for visualization     Teeth segmentation mode     Displays the Tooth panel to view and  manipulate the teeth and jaw as separate objects    Multi view   Displays five views of the same virtual cast in separate  windows  Right side view  Front view  Left side view  Mandibular view and  Maxillary view    Cross section   Allows to create the 2D cross section of the model at any  Stage of the workflow    Measurements and Custom Analysis   Allows perform 3D measu
3.      Model set ID    Model Set Comparison    Model   isibility A    Reference Both Compare      J          To activate this option  click    the pi Compare model  sets button in the Main  toolbar while one of the  patient models is already  loaded     This will open the Open  patient model set window  with the model sets listed in  the search results for the  chosen patient  Select the  model set you wish to  compare the already loaded  one to and click the Load  button     This loads the second model  set  The two model sets are  displayed in the same  position but with different  colors     The visibility of the models can be operated from the  appeared Model Set Comparison window     The reference model is shown in green and the compare  model has yellow color   The model visibility  color  can be gradually changed       with the slider or toggled with the Show       reference model set only and  model set only buttons     Show compare    The Show both model sets button returns the  slider to the middle position     The   Animate to reference model sets and  Animate to compare model sets buttons slowly  move the sliding bar from one end to the other in the  corresponding animation        3Shape A S   Holmens Kanal 7  DK 1060 Copenhagen K  Phone  45 70 27 26 20    3Shape Inc   571 Central Ave   Suite 109   New Providence  New Jersey 07974  Phone   1 908 219 46 41    3Shape Asia   Room 1205  No 738 Shangcheng Road  200120 Shanghai   Phone   86 138 183 38960    97    Mail  in
4.     3 Interactive Tools    These tools positioned on the Visualization toolbar can be activated at any step of the  analysis and planning process    Activation  In order to avoid conflicts in user input between the open Function and the  chosen tool  articulator  3d measurements or 2D Cross section  and to be able to toggle  between them  click on the tools    window to activate the given tool or on the function  window  The active feature window is marked blue as illustrated     3Shape A S 3Shape Inc  3Shape Asia 24  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Virtual articulation       E  F  Occlusion 0 00 mm E  Laterotrusion o oo mm   Pro fretrusion 0 00 mm E    Contact mode As     _  Collide designs  Record contacts G              Interactive tool  Virtual articulator active    3 1 Articulator       VC The Virtual Articulator feature can be activated with the Articulator button in the  Visualization toolbar any time during the analysis or planning process            Step 1  Align the jaws position  You can set the jaws in the desired positions by clicking the      irtual articulation       Modify   button in the Virtual Articulation window and 
5.     ET maxilla ry model to adjust  rotate                Modification x  Trans box     Arrow buttons  Translation step 0 10   mm   Rotation step 1 00    deg   Collision detect      Plane grid A  Measurement points S  Show measures       oo  ze          4 1 2 Alignment for Open Model Set    The Alignment for open model set function helps to align the upper and the lower    vr casts for the open model  Follow the hints written on the form in green to perform the  alignment     You can use either the Modification section to insert the desired distances for the  alignment  please see chapter Occlusion for more details  or the Alignment by planes  section  To use the latter one  please click on the Set points button and place 3 points on  each of the casts  Click the Apply button to perform the alignment  Click Clear to place the  points all over again  Click Reset to start the alignment from the beginning     3Shape A S 3Shape Inc  3Shape Asia 52  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2 D gt   Ortho System    2012 User Manual    When the Show intersection checkbox is selected  you  can view the gray intersection plane on one of the casts  after you have placed the first three points on t
6.     m  the Mb ation  model set button in the Main toolbar  Then the empty Open patient case  window pops up suggesting to search for a patient     Search patient ID  Search patient 55M  Search patient address    Search clinic ID    Match whole text       e To view model sets for inspection  search for them using the search bar in the right  corner of the window  which includes various criteria to search with for the necessary  patient model set s   e g  patient   s ID or address     e To see all available model sets set in the Control Panel  click Search leaving the  search bar blank  A list of patients sorted by their IDs will appear under Patient  Selection  which would offer model set s  for further inspection    e The system employs several indications displayed in the main window to help you  look for the necessary model sets in the catalogue     a   a Clicking on the root of the Patient Selection tree will display patients    IDs and    names    3Shape A S 3Shape Inc  3Shape Asia 7  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road   DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    E Open patient case       O  b    Clicking on one of the patient ID  name  in the catalogue will display the ID   opera
7.    1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p    gt   Ortho System    2012 User Manual       OrthoAnalyzer is an advanced 3D analysis and measuring software package for  orthodontists to facilitate fast and easy 3D analysis as well as advanced treatment planning  from digital study models     This manual introduces the OrthoAnalyzer software s functions     From herein  it is assumed that the OrthoAnalyzer user is familiar with basic orthodontics  terms and concepts     OrthoAnalyzer 2012 IMPORTANT INFORMATION AND LEGAL DISCLAIMER    The functionality of the OrthoAnalyzer    software allows you to manipulate a 3D visual  model of a patient   s dentition by dragging and moving individual teeth in the model  such  that you may explore how the visual appearance of the dentition may change if such tooth  movements were implemented     Please be informed that the OrthoAnalyzer    software does not in any way attempt to check  if any specific tooth movement or combination of tooth movements visualized in the  software is actually possible to implement on the patient in real life     Manipulations visualized in the software may not be possible to implement in real life  e g   because the teeth may not actually be moved as visualized  A visualization created in the  software of any tooth movements may also be inaccurate  e g  because such movements  if  implemented in real life  might cause more or 
8.    1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3S h a p e  gt   Ortho System    2012 User Manual       Move the plane along the jaw by pulling the slider of the Plane offset slide bar   It is possible to open this function on any stage of your modelling process     3Shape A S 3Shape Inc  3Shape Asia 46  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2 D gt   Ortho System    2012 User Manual    4 Function Panel    Each stage in the analysis and planning process is represented by a tab in the Function  panel     As different jobs require different functions  the Function panel changes its look depending  on a job  You are free to choose the first step in the Function panel to complete  Therefore   there is typically no a predetermined workflow of tasks however  the tasks can be organized  in predefined workflows by using the workflow wizard  see section Customized Workflow  Wizard   An example of a workflow is the Analysis tab which deduces the analytical  meaning out of the measurements set up in the Configuration section     A brief overview of functions available in the Function panel is presented in the table below     
9.    A   ball   k JL J ES     Custom objects       Measures     Measurel  4 Planes    Sagittal plane    Horizontal plane          EA     TT Show all  JH Jo    _  Show selected tooth only      Show all without selected tooth       Show teeth only       Show jaw without teeth      Make non selected teeth transparent   _  Show neighbour teeth only     _  Show original for selected tooth   _  Show mirror for selected tooth    Show tooth markers      Anterior posterior plane    Occlusion pilane       Inclination  Angulation  Rotation  Left Right  Forward Backward    2001  2001  Holmens Kanal 7        Sr Step 3  Export the ready model    and setups to a specific folder  Left click on it to get a Save as    window and    R The Export models as    button in the Main toolbar allows saving the models     export the model for the current setup        3Shape A S 3Shape Inc  3Shape Asia 64  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    The Save virtual setup as    option has two   The Save models as    option saves a options  you can save the upper and or lower   copy of the existing upper and or lower model s  as models or as a model set  Mark  model s  to the spe
10.    Zeeninn                Multi view Show material and shadows Show perspective  L OI  a    LR       Show wireframe Show as transparent    You can capture a screenshot of the model s current view by clicking at the Screenshot    att  hy      e Thereisa  preview window   Screen snapshot information   of a screenshot to     the left    e You can see the  Comment field  for your notes    e The date and time  of the snapshot  can be set up in  the corresponding   Date 08 12 2010 fields    e Click at the  Create button to  save the  screenshot in the  patient s folder     Preview  Comment    Time  15 02 42       You can observe the screenshot in the Screen snapshots tab after selecting the patient and  the appropriate patient s model     3Shape A S 3Shape Inc  3Shape Asia 23  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual    Open patient case      PEE    a    Patient Selection       b  g Jane Doe  rE A John Doe    08 12 2010 15 08 41    3 2000   Model set date 24 03 2010  tID 2 ydel set scan date 24 03 2010  ne 14 55 16  it post treatment       The screenshot will be saved by default to  C  ProgramData  3Shape  OrthoData Patient s ID Model set ID  Captures    
11.    clicking a landmark and selecting the color and form  of the landmark from the drop down menu         lsBall     m lsCone  IsArrow    Angles are defined by three landmarks and the  measurements which are immediately displayed   It is possible to customize the view of the  measurement by right clicking it and selecting  Properties from the pop up menu        You can open this pop up menu by right clicking  the appropriate measurement in the Custom  objects window        3Shape A S 3Shape Inc  3Shape Asia 32  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual           Planes    Set a plane by positioning three  landmarks on the model    Itis possible to customize the plane by  right clicking its name in the Custom  objects window       Plane  Planel    Open Planel in Cross section    Annotate  Delete       Properties       Measures       turns 9 aed 8                Place two landmarks on the surface of  the model to make the measurement  It  is possible to edit it by right clicking the  measurement line  if place a cursor on it  turns MALG  if selected turns MER    You can mA the Measure type from  the drop down menu after right clicking  the measurement and sele
12.    sets up the distance for which the cast    J m moves up or down at one click on the arrow   Plane grid we    Measurement points   SZ Rotation step   sets up the degree of rotation of the model        e Orientation plane         1  Customize the orientation plane with the help of the      three control points   check the Show plane grid    E checkbox  and select three points on the models defining  Please place 3 points for the plane   the plane grid    2  Define the distance between the two virtual casts to be  Modification moved apart according to the orientation plane  Negative    values make the cast move up  positive   down  To edit the    Trans box    Arrow buttons   position of the plane  drag the control points  correspondingly                 Maxillary distance 0 00 SS  mm                 Mandibular distance 0 00    mm    3  Click Clear to clear the control points that define current  positioning of the orientation plane and re define it     Collision detect    Plane grid A  Show plane grid    Measurement points          br Step 3  Detect collisions and repeat step 2 trying to avoid them  if applicable     3Shape A S 3Shape Inc  3Shape Asia 50  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S
13.   50  and 80  respectively  Curvature sets the amount of curvedness for the  base model along the sides     AP     e Create base       Once adjustments to the bounding box at  the Fit base step are complete  click the  Next or Create base button to create the  virtual base        Click OK to close the Virtual base dialog  window  Your models now appear to have  virtual bases     Base offset Omm and 2mm respectively       The image below shows the virtual base using the included Arch Max and Arch Man bases    STL models    3Shape A S 3Shape Inc  3Shape Asia 111  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road   DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual       e  gt  Export models as       Save models    Once creation of the    Upper model virtual base is finished   it is necessary to save  Save Upper model the models     Upper model filename  L    C  Documents and Settings kal Users 4pplication Data  35 hapes  Click the Export    models as    button  and select the    Lower model checkboxes to save  either both or only  Jave lower model Upper Lower model in    L del fil the appeared Save  EE EE models dialog  browse    C  Documents and Settings 4ll Users4pplication Data  35 hapesl to the desired loc
14.   Offset wire arc length  108 02 mm        Mandibular arch     Show opposite arch  sadetofket 05    Ideal arc length  0 00 mm    Offset wire arc length  0 00 mm    e Ideal Curve and Wire Length tab           Before defining an arch  you have to click the Add button and enter a name for your new  ideal arch  arches   The new arch will appear in the Ideal Arches drop down list  You can  delete the selected arch with the Remove button     The Maxillary arch and Mandibular arch tabs offer the following options  the same for  the upper and the lower arches   Define an ideal arch based on different default shapes   There are four types of ideal curve shapes available in the system     3Shape A S 3Shape Inc  3Shape Asia   Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com  Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    83    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Ellipse Custom    Compare the existing shape of the teeth row with an ideal curve and consider the necessary  modifications to the existing shape     Placing control points for the Custom arch Editing the Custom arch          Select the arch shape and place several control points on the model to set up the ideal  curve  two points for Ellipse and Parabola  the third point will appear automatic
15.   Ortho System    2012 User Manual    1  The dark grey field at the bottom of the window summarizes the information related  to the active selection   2  The top toolbar window modifies its content according to the active selection     a  While you are at the Patient selection  the only option available at this stage is     B New patient creates a new patient in the patient database  see chapter New  patient       A Import from file button permits to import models from other folders     b  Selecting a patient model set adds two additional buttons     New model set allows you to create a new patient model set for the selected    patient  see chapter New model set        Edit patient    button opens the existing patient information form of the selected  L   patient for editing  Click Change to save changes     B Export to file allows you to save the selected file in the selected folder     When you select the Export to file    gt  button you will open the window  where you can  select the folder where it will be exported to  The format for the exported files is  3sz     Save in  A Andreas Friedrich  Nee   Mag   Date modified  Recent Places    No items match your search     File name   001_1_export    Save as type  Ortho System import fest ez        Selecting the Import from file in button opens the Import window  where you can  select the folder the file will be imported from  The format for imported files is  3sz     3Shape A S 3Shape Inc  3Shape Asia 11  Holmens Kanal 7 571 C
16.   Please refer to the Ortho Control Panel  manual  section Questionnaires  for the details           Questionnaires          Korkhaus Schwartz Analyses       o Please place landmark UR4 in the groove of the first upper right premolar  UR4  and  Korkhaus Schwartz Maxilla landmark UL4in the groove of the first left premolar  UL4     Korkhaus A  Korkhaus B  Line Korknhaus U4 4   Korkhaus C  Line Korkhaus U6_6   Korkhaus D  Korkhaus Distance U1       Korkhaus Schwartz Mandible  Korkhaus B1  Korkhaus Line L4_4     Korkhaus C1  Korkhaus Line L6_6   Summary      Korkhaus_UR4 Wl Korkhaus_U4_4    Korkhaus_UL4         V  Korkhaus B  Line Korkhaus 32 75  Korkhaus B Ideal 42  Korkhaus B Discrepancy  9 25          amp        1  Available Questionnaires 5  Content of the question   2  List of steps 6  The illustrating image   3  Unweighted Total of scores 7  The model with the measurements   4  Weighted Total of scores 8  The Previous Next buttons  3Shape A S 3Shape Inc  3Shape Asia  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road 21  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    1  The Questionnaire drop down menu presents the list of Questionnaires available for  filling  To choose the one you need  press the arrow
17.   Suite 109   New Providence  New Jersey 07974  Phone   1 908 219 46 41    3shape gt        To make this  measurement place a  few control points that  define the spline   Double click the last  control point to close    the spline   3Shape Asia 35  Room 1205  No 738 Shangcheng Road  200120 Shanghai Mail  info 3shape com    Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p    gt   Ortho System    2012 User Manual    Custom objects    To create new custom spline  set ist  landmark      Measures    Measurel  4 Angles To hide the measurement  click the green    Anglel tick in front of the measurement plane   4 Planes The selected object is highlighted blue   Sagittal plane To fold unfold the groups click the   arrow  Kier SES in front of its name     4nterior   posterior plane  Gecusian Diane  4 Custom splines    Custom splinel    Custom splinez             To define collection click its  Start  button in the list below        4 Korkhaus Schwarz Analysis ts               keel Click the Collections icon to open the  o n appropriate tab     Korkhaus_U6_6 5 45   f f  Follow the instructions displayed at the top of the    korkhaus_L4_4 17 45     window      korkhaus_L6_6 6 66   Stari  4 Distances Click the Start  7 button to begin the     Korkhaus_D 11 24 process      Korkhaus_LD 29 87 The results of the measurements performed on the  4 Calculations   model will be displayed in the table      kKorkbhaus A Soma     Korkhaus_
18.  2D tooth length checkbox located on System Settings  page of the Ortho Control Panel     Clear       Clear All       Show teeth   s axes     when checked  displays the teeth axes in the form of  the red arrows  The tooth axis can be changed with the help of the Set tooth  normal button in the upper left corner of the session window  Its position is  by default set by the user defined mesial distal segment     Move close points synchronously   when checked  simultaneously moves the control  points that are set close together on the spline  used at the Define cut step      Use the Mesial Distal point cross section window at the bottom right corner of the session  window for the following tasks     1  Drag the  control points  in the cross   section  window to  move them  along the  cross section  defined by  the mesial  and the distal  points on the  virtual model  in the  modeling  window while          3Shape A S   Holmens Kanal 7  DK 1060 Copenhagen K  Phone  45 70 27 26 20    3Shape Inc    571 Central Ave   Suite 109   New Providence  New Jersey 07974  Phone   1 908 219 46 41    3Shape Asia 72  Room 1205  No 738 Shangcheng Road  200120 Shanghai   Phone   86 138 183 38960    Mail  info 3shape com  Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    the cross  section tooth  width is  calculated  automatically    2  To  measure the  cross section  areas of the  tooth width  segment   position th
19.  Maxilla Korkhaus Schwartz Maxilla   Korkhaus A Korkhaus A    Korkhaus B  Line Korkhaus U4_4  Korkhaus B  Line Korkhaus U4_4   Korkhaus C  Line Korkhaus U6_6  Korkhaus B Ideal    Korkhaus D  Korkhaus Distance U1  i  Korkhaus Schwartz Mandible ee ee  Korkhaus B1  Korkhaus Line L4_4  ee eee  Korkhaus C1  Korkhaus Line L6_ e Korkhaus C Ideal  Korkhaus C Discrepancy    Korkhaus D  Korkhaus Distance U1_1   Korkhaus D Ideal  Korkhaus D Discrepancy   Korkhaus Schwartz Mandible   Korkhaus B1  Korkhaus Line LA 4   Korkhaus B1 Ideal  Korkhaus B1 Discrepancy  Korkhaus C1  Korkhaus Line L6_6   Korkhaus C1 Ideal  Korkhaus C1 Discrepancy    Unweighted Total Weighted Total    Click OK to end the test        4 3 5 Generate Report    The Generate report function organizes the data contained in both  the Configuration  and Analysis sections into a separate printable document        We     we   Report type 1  Click the V   Generate report button on the  cael  2  In the appeared Custom Report dialog box    Report template select the Report type you wish to make  The  report type depends on the information you need   to include in the report  Report types and their   structures can be defined in the Ortho Control   Generate report Panel  Feature Settings  gt Custom Report    Configuration   3Shape A S 3Shape Inc  3Shape Asia 94  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com
20.  Points     ei Set points   the first step of the preparation process     Click on the fkeegaegen for maxillary model icon  the program automatically brings  you to the first step     The system automatically presents the model of an open  mouth view  making the inactive part of the virtual cast  transparent  as shown on the image      At this step  you have to place the distal and mesial control  points on the teeth to setup the maxillary model  To  accomplish this task  mentally divide the model into two  parts along the median line  and indicate the distal points   aqua  on the surface of the tooth that is away from the  median line  and the mesial points  purple  on the surface  that is towards the median line  as shown on the image  below  The width value for each tooth is displayed under  Width  2D  under the Overview window     To remove the tooth width selection  right click on the  control point and select Delete from the appeared menu     To move the control points  click on the control point to  activate the tooth and drag the point with the cursor        3Shape A S 3Shape Inc  3Shape Asia 70  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p e  gt   Ortho System    2012 User Manual    C
21.  an overview  of the teeth to be measured  Click on the teeth in the  Objects window to select them for operation  The  Overbite function is available only for the central  incisors and is not active for the lateral incisors  see the  image      The selected tooth is circled in red  The teeth that have  already been measured become green     Place the landmarks on the necessary teeth in the  session window or in the 2D cross section  see images  below   You can always move the landmarks by  dragging them with the cursor     Enable clipping plane     When selected  cuts away the  portion of the model  see images below      Invert clipping plane     When selected  cuts away the    3Shape Asia 88  Room 1205  No 738 Shangcheng Road  200120 Shanghai    Phone   86 138 183 38960    Mail  info 3shape com  Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3S h a p e  gt   Ortho System    2012 User Manual    opposite portion of the model     Select Show all to view all the overbite overjet  measurements on the model     Select Show landmarks to show hide the landmarks on  the model     Click Clear to remove the measurements from the  selected tooth  Click Clear all to delete all the  measurements on the model                                a a e E E       Overbite measurements    3Shape A S 3Shape Inc  3Shape Asia  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road 89   DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shan
22.  by holding the left button on the mouse     Promermenio co   og the red control point appears and the parameters are       updated automatically      Contact mode Gen DS       Collide designs E   Record contacts          A Wl  Click the locked is button to change it to the unlocked to  free the movement of the required plane  Place the cursor over  the articulator model and drag it while keeping the mouse button  pressed           With the Upper OD   Lower fa jaw button you can select the jaw you want to move with  when resetting    the articulator to the static occlusion     3Shape A S 3Shape Inc  3Shape Asia 29  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Click to lock the modelling position of the articulator  To set the articulator in modelling  position click      There are three options in the Articulate function     Contact mode   e on   contacts are recorded but the articulator can be manipulated freely like a  physical articulator  e off   no contact is recorded  e auto shut  AS    will always maintain a contact between the two jaws  so in effect  the articulator cannot be opened completely     Collide designs   indicates in color the col
23.  either select them  using the option described above or to browse for any of the two models in the  General field  The system automatically locates the pair model in the same folder to  form a properly occluded double cast for further inspection     3Shape A S 3Shape Inc  3Shape Asia 16  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Open models      d  General      C ProgramD ata 35 hapeSOrthoD ata 2000 2 20000 2  Mandibular     Show preview  C  Decimate db models to    200000  triangles    Maxillary model    Mavller model filename     C  ProgramD atas aS hapeOrthoD ata 2000   2000 2 MAxILLAF    Browse    Number of tangles  92708  Number of vertices  46056    Mandibular model  Mandibular model filename   C  FProgramD atas aS hape OrthoD atasz000s2 20002 Mandibular    Browse    Number of tangles  97806  Number of vertices  46905       br Step 3  Check Show preview to see the selections made in the preview boxes to the  right of the window       Step 4  Check Decimate db models to   triangles to decrease the number of triangles  on the model to a predefined value     Step 5  Click Rotate to set the appropriate rotation angle for the relational positio
24.  fields in the form contain administrative and personal data of the patient for whom the  order is created     A few of the fields are explained below     e Patient ID   This field is reserved for the patient   s unique ID  It is a manually  maintained string of alphanumeric symbols   SSN     Stands for the patient   s Social Security Number   Clinic     A description string for the clinic the session is being held for and is made  for the scanning centers  To use this option the clinic and its data have to be  previously registered in Orthodontics Control Panel     Click Create to save the data entered     3Shape A S 3Shape Inc  3Shape Asia 5  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual    1 2 2 New Model Set       This step creates a new model set for the current patient by letting you fill in a small dialog          F  box  Click the      i model set button to get the New patient model set info window     Model set operator Model set comment Model set date Model set scan date    Model set information  Attach model  Patient id     Model set id     Comment     Operator    Model set date  2a 12 2070  Scan date  23 1 2 201 i  Scan time  110458    At mm 
25.  h a p e  gt   Ortho System    2012 User Manual _ _ S    i  13 Hint  Use Show as transparent function  the Visualization toolbar  to visualize  d    collisions more clearly            Transbox Arrow buttons      Maxillary distance 0 00   s mm     Mandibular distance 0 00    mm     Plane grid 7             Measurement points       ape gt        Click the Correct button to place the model in the initial  position        Step 4  Use the following buttons to control saving and clearing the changes  applied     e Click Reset to reset all changes and start aligning the virtual casts all over   e Click Cancel to cancel the last change and leave the step   e Click OK to save the changes and leave the step         Step 5  Inspect the changes at specific points     e Inthe Measurement points group click Insert points   Click on the models to define points of interest   the difference at these points will  be shown with labels on the models    e When changing the model articulation the distance moved for every specified point  will be shown as a measurement label on the models     3Shape A S 3Shape Inc  3Shape Asia 51  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual   
26.  i   gt   Ortho System    2012 User Manual    Prepare maxillary model       Show teeth s axes  Move dose points synchronously    Tooth long axis angle  84 79 deg    P   r       3Shape A S 3Shape Inc  3Shape Asia 78  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual       3Shape Inc    571 Central Ave   Suite 109   New Providence  New Jersey 07974  Phone   1 908 219 46 41    3Shape A S   Holmens Kanal 7  DK 1060 Copenhagen K  Phone  45 70 27 26 20    3shape gt     3Shape Asia   Room 1205  No 738 Shangcheng Road  200120 Shanghai   Phone   86 138 183 38960    79    Mail  info 3shape com  Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    Step 3 3  Finish    hy At this last step of the Preparation for maxillary  model option you can evaluate your model and choose  to go back to the previous steps if more adjustments  are needed    To go back to any of the previous steps  click on the    a b    step icon or on the green arrow buttons    wf   init h     SCH e     v  Move close points synchronously Click OK to finish the Preparation for maxillary    model        You can also edit the position of the rot
27.  maxillary model    Hide inactive items    JP Add    2D cross section    Analysis objects    Cross section along dental arc       Analysis reports  Dental arc analysis  Generate Report  Overbite OQveret  Questionnaires    E Copy   A Delete   EN Move up  a Move down  F Export    ob Import          Recycle bin                Change ID    Change ID  Please select a valid unigue ID     ID    OK    Cancel         3Shape A S   Holmens Kanal 7  DK 1060 Copenhagen K  Phone  45 70 27 26 20    3Shape Inc   571 Central Ave   Suite 109    Phone   1 908 219 46 41       New Providence  New Jersey 07974      Setup occlusion plane    Preparation maxillary model    Preparation mandibular model       e Adding a new wizard    When creating a new wizard  click the Add  button to add the wizard ID in the appeared  Selection of ID window     Once the new wizard is added it appears in the  Workflow list on the left  Inactive wizards can  be hidden from the list by selecting the  required wizard and ticking the Hide inactive  items checkbox     All available steps of a wizard are shown under  All steps listing while the wizard remains  selected     3Shape Asia 114  Room 1205  No 738 Shangcheng Road  200120 Shanghai    Phone   86 138 183 38960    Mail  info 3shape com  Web  www 3shape com       Copyright 2006 2011 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2010 User Manual    Select the required steps for the created wizard  and transfer them to the Current workflow    steps list o
28.  moving the control points with the cursor for a better fit  see the  images below      Occlusal change can be set directly by clicking the value and  entering in the numbers directly or selecting it with the buttons  next to the value     f Use the buttons in the Virtual articulation window to undo your  CotSal change Don mm changes to the static occlusion  1  or update the static occlusion   gt  with the current alignment of the jaws  when you are satisfied  Optimize occlusion with the results  2         Select Optimize occlusion to align the jaws automatically     3Shape A S 3Shape Inc  3Shape Asia 25  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual          Click the button on the Virtual articulator window to  start the setup     Select the type of the articulator from the drop down menu after    clicking the black arrow    Bennett L  Bennett R  Cond  incl  L  Cond  incl  R are   ACR  4artex    compatible  EN articulator model parameters  they can be set by clicking the  appropriate editboxes and entering their parameters manually or   Bennett L 10 00    selecting them with the buttons next to the values    el 10 00       The Auto placement  1  butto
29.  new patient entry  the  second is for working on already created cases  and the third is for running an independent  session with no patient database attachments        1 1 Executing OrthoAnalyzer       d  OrthoAnalyzer    is started by double clicking the OrthoAnalyzer    desktop icon 8  or via  the Windows    Start menu  Start     Programs     3Shape     OrthoAnalyzer  When the  application starts  the following screen appears        3Shape A S 3Shape Inc  3Shape Asia 4  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual _ _ S       1 2 Creating a New Database Entry    1 2 1 New Patient    Before starting an analysis session  a patient database needs to be created  To create a new    20 p  patient  click on the D model set button in the Main toolbar and select  New patient  A New patient info form will pop up     CH Open patient case o z  o leale        Patient last name Patient first name    i   Patient information  Patient id  133 abe  55N  1001 12345                                           First name  John                Lastname     Wayne    Address  Mam Street                      City  Hollywood  Country  us    Clinic    Default                The
30.  p    gt   Ortho System    2012 User Manual       When you first come to this step the only setup  Please  select subsetup or available is the default one  You can create a new setup  go to the next step  by clicking the Add button  Enter a name for the new  virtual setup in the pop up window and click OK   Sech copy  If you want to create subsetups for your scenario  enter  the number of subsetups desired in the Count field and  click Subdivide  The program will automatically create  the desired number of subsetups named Subsetup1   Subsetup2 etc  When you first go to the Choose setup  step the only subsetup available is the Original and after  you create your own setup or subsetups  there also  appears the Ideal one  which is the final setup     Click Show to view your setups  click Delete to remove  them     Select Copy to duplicate the existing setup  The new  setup will be marked as a copy                          Transform tissue     If you want the tissue  the pink material of the gums  to     EEE De moved when moving the teeth  select the  Transform tissue checkbox    E   With the Edit flexible tissue region button it is     possible to determine the area of the gigiva with the  splines under the teeth that will not be corrected during  the step     When done with creating or choosing setups  click either    the m Next step or dy Extract teeth button to  proceed to the next  Extract teeth step     It is possible to export all the models of the setups with subsetups on
31.  performed actions with a single tooth you can use the green    arrows in the left upper corner to Undo Redo the changes  or the    combination of Ctrl   Z Ctrl   Y      To move to the next step click either the   Next step  Next or hy Finish buttons   Hint  Due to difficulty to access interproximal areas for most orthodontic cases it  can be necessary to adjust the suggested segmentation manually  In case  segmentation fails for one given tooth  it is recommended to start by repositioning  the distal and mesial points at the first step  If this is not sufficient to solve the  segmentation issue  it can also be very useful to inspect the cutting splines alone    W   cur   on screen  disable the    Show maxilla or    Show mandible button  respectively from the Visualization Toolbar and adapt the spline using the Spline  Fast Edit mode     Tooth long axis angle   When an occlusion plane has been created  see section 4 2 2   it is possible to check the  angle of the selected tooth   s long axis according to this plane    Select the Show tooth long axis option from the list  the axis angle for the selected tooth       3Shape A S 3Shape Inc  3Shape Asia 77  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p
32.  see the    3Shape A S 3Shape Inc  3Shape Asia 14  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    chapter Patient Model Set  you may employ the GL  model set option to see the  record of just the patient case specific to the model opened  The function is provided in  order to open a different model set for the same patient and to compare models while  making a complete analysis of a single model set     1 4 Starting an Independent Session       1 4 1 New Session    sl    Model sets can be created using the   New session function  A new blank session  window will appear with the main toolbar suggesting loading scans in  dcm or  stl format to  start a new analysis session outside of the patient database system     Patient model set    ew session  Open models    Save session    Export models as          aaaaaaaa    SASS  9 8           Actual frame rate   0 0 fps  Achievable OpenGL frame rate  39 3 fps     1 4 2 Open Models    To start an analysis session it is first necessary to open existing models for inspection     3Shape A S 3Shape Inc  3Shape Asia 15  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New 
33.  slope   Thereby  you can select  the most appropriate  position of the plane for  making on grid       measurements   Use the manipulation buttons to operate with the cross section   3Shape A S 3Shape Inc  3Shape Asia 39  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    op view options   includes the buttons that set the viewing parameters     Clipping plane   Left   Hides the right side of the model in relation to the  cross section plane     Clipping plane   Right   Hides the left side of the model in relation to the  cross section plane     Fixed camera   Locks the plane in one position and moves the model  instead     Grid   Turns on off the grid on the plane     Along Dental Arc   Allows you to  position the cross section along the  dental arc with the spline  shown in  green  going through its center   Standard planes   Allows you to  select the plane from the list of the  planes you create     Save plane   Allows you to save the   created plane     Clear View   Removes cross section     Measure area   Allows you to  measure distance on the model in the  2D Cross section window     Clear measure   Deletes the    Zoom all   Allows you to zoom t
34.  this step  In the Save  Virtual setup as section you can observe the hierarchy of all the setups and subsetaps in the  current project  You can fold unfold the groups by clicking the dash     3Shape A S 3Shape Inc  3Shape Asia 55  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual _ _ S    Save models as     Save occlusion as       Save virtual setup as    Fl test 3  Upper Model C  ProgramData 3Shape  OrthoData 2011 1     Lower Model C  ProgramData 3Shape  OrthoData 2011 1     Model set 2011 09 06 11 1  Doe V5 test 3 _    Subsetupi1  Upper Model  C  ProgramData 3Shape OrthoData 2011 1     Lower Model      C   ProgramData 3Shape OrthoData 2011 1     Model set 2011 09 06_ 11 12 Doe Ve fest 3 Subs       rs   Upper Model C  ProgramData 3Shape  OrthoData 2011 1     Lower Model    C   ProgramData 3Shape OrthoData 2011 1     Model set 2011 09 06_11 17 Doe VS fest 3 Subs          a   gt     Merge attachments with models    Duplicate model set           4 1 3 2 Extract Teeth    sw At the second step of the Virtual Setup  the Extract teeth step  you can simulate  v teeth extraction     To perform the operation  left click on the teeth you want to extract  the sele
35.  to the right and select the appropriate  test from the drop down menu    To load another questionnaire to this list go to the Ortho Control Panel     2  The List of steps presents the sequence of groups and steps that you created in the  Control Panel  Selection of each group or step with the a single click opens its content to the  right     3  The Unweighted Total indicates the unweighted amount of scores  total scoring value  of the questions      4  The Weighted Total shows the weighted total of scores     5  The Content of a step contains the question and other components that you have set in  the Control panel     6  The illustrating image functions as a hint  describing what measurements should be  performed on the model on this step     8  The Previous Next buttons allow you to move up or down the list of groups and steps     After selecting the first question out of the group with a single click  Click the Define button  and measure the appropriate segment on the model     3Shape A S 3Shape Inc  3Shape Asia 92  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Questionnaires  z     meg   Please place landmark UR6 in the groove of the first uppe
36.  version  installs 3 pre made customized workflow wizards by default  As shown on the image  the  wizards are represented by the hat icons of varying color and are located in the toolbar of    the OrthoAnalyzer     The supplied wizards are named as follows     AA                                        3Shape A S 3Shape Inc   Holmens Kanal 7 571 Central Ave   Suite 109  DK 1060 Copenhagen K New Providence  New Jersey 07974    Phone  45 70 27 26 20 Phone   1 908 219 46 41    1  Preparation  2  VirtualSetup  3  Analyzer    3Shape Asia   Room 1205  No 738 Shangcheng Road  200120 Shanghai   Phone   86 138 183 38960    113    Mail  info 3shape com  Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual    3shape     The wizards are setup and edited in the Ortho Control Panel  You can use and edit the pre   made wizards or add your new wizards  In order to setup or edit the wizard  open Workflow  Settings of the Orthor Control Panel  The following image shows 3 pre made wizards set up    in the Ortho Control Panel     Le    Orthodontics System Control Panel   Workflow       a2      Back    ml    Save    Val    Home Help    Workflows Settings   Workflows    Workflow    Edit Workflow  Preparation  VirtualSetup     ID  Analyzer  Name    Workflow color    All steps    Move teeth  Occlusion map  Measurements    LS      eee    Preparation    Preparation    Current workflow steps      Alignment for open model set    Setup local origo on
37. 0 Copenhagen K New Providence  New Jersey 07974  Phone  45 70 27 26 20 Phone   1 908 219 46 41    Hint  To create the smallest  virtual bases  select the      provided Arch base model out     of the base models list  You  izi can also import your own base  models     Please refer to the Ortho Control Panel  manual  chapter Construction Elements   to learn how to add these models to the  list     Select the arch_man arch_max base  models from the drop down menu in the  Select base model section     Decide on the part of the model you wish  to leave  click the Define cut button if not  already at this step and place the spline  points over the model curve to define the  cut  Click the first point of the spline to  close it     Where needed  adjust the spline manually  by dragging the points with the cursor to  the required position     Remove    Clear spline  Fast edit       3Shape Asia 109  Room 1205  No 738 Shangcheng Road  200120 Shanghai Mail  info 3shape com    Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 UserManual _ _ S    For Fast edit  left click on the spline and  move the cursor while holding the mouse  button down to draw a new part of the  Spline        e Fit base    Once maxilla and mandible splines have been placed  click the Next or the Fit base buttons  to go to the Fit base step     You can adjust orientation of the base by dragging the violet points and the base s
38. 2 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual       ae  eva       Set Tooth Normal    When the Show teeth   s axes checkbox is selected  the teeth axes become  visualized in the form of the red arrows  The tooth axis can be changed with  the help of the button in the upper left corner of the session window  To  perform the operation  select the tooth to make it active  position the cast as  desired and click the Set tooth normal button  Note that the default position  of the tooth axis is defined by the mesial distal segment        3Shape A S 3Shape Inc  3Shape Asia 74  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3S h a p e  gt   Ortho System    2012 User Manual       Segment Tooth Manually    To place a new spline  select the desired tooth to make it active and click  Segment tooth manually button  The spline that has been placed  automatically by the program will disappear and you will be able to place your  own spline  Left click on the tooth to place the control points  The last control  point should be placed on top of the first one to close the spline           Spline Fast Edit Mode    To fast edit the spline  select the desired tooth to make it active and cl
39. 2001  oer ity Copenhagen  2001    atient country Denmark  tname Jane Doe    dress Holmens Kanal 7       The section Attach model lets you select the new model set intended for import  Click  Create to save the entered data  The description of the fields in the form is provided below     e Model set ID   Corresponds to the ID string that uniquely identifies the model set  for a particular patient    e Comment   Any comments related to the order or the model can be added here   Operator   Fill in the name or the code of the operator performing model set  analysis    e Model set date   The date the model was created  the default date can be  modified     e Scan date and Scan time   The Date and time the scan was taken  the default  date and time can be modified      ell bell           Note  The information specified in New patient and New patient model set  appears at the bottom left corner of the session window for reference     co    3Shape A S 3Shape Inc  3Shape Asia 6  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual _ _ S       1 3 Returning to the Database Entry    Another option to start analysis session is to open an existing patient model set by clicking
40. 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com          Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual    Click either the   Next step or Y Move teeth button to go to the next step     4 1 3 4 Move Teeth    The last step of the Virtual Setup  the Move teeth step  allows you to rotate and move  teeth as desired  To select the tooth  click on it with the mouse or use the arrow   s   buttons on the keyboard  The selected tooth turns blue  Double click on the tooth to  activate the red and green control points that will help you rotate and move the tooth  as shown on the image     br Step 1 Align the selected tooth  To do that  perform the following actions     e Rotate the tooth  click on the red control points on the tooth or use the Left   Right  arrow keys     e Move the tooth  to move the tooth up and down click its green control point and  drag it or use the Up and Down arrow keys  to move the tooth sideways click tooth  and drag it or use the arrow   Ctrl keys     Step 4 4  Move teeth       e   go      Ideal arch options a    Show ideal arches    Show Maxillary Ideal Arch       Show Mandibular Ideal Arch    _  Show as 3D  Miscellaneous a  Rotation interval ideg D  Shift interval oim  amp     1  Make non selected teeth transparent 5   E  Show neighbor teeth only        Perform collision detection    F  Threshold 0 25mm Se  Measurement points N   Show measures    oe  ee    Ideal arch options 
41. 4  Motion view section    The List of sequences can be customized with the Operation buttons  Add new  sequence  Move up down the list or Delete from the list        3 2 3D Measurements and Custom Analysis       the desired 3D measurements on the  Landmarks  3Shape A S 3Shape Inc   Holmens Kanal 7 571 Central Ave   Suite 109  DK 1060 Copenhagen K New Providence  New Jersey 07974  Phone  45 70 27 26 20 Phone   1 908 219 46 41    The Measurements and Custom Analysis option allows you to perform and edit    model    3Shape Asia 31  Room 1205  No 738 Shangcheng Road   200120 Shanghai Mail  info 3shape com    Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Landmarks represent simple  red  points that define angles  occlusion planes  cross   sections  sections for measurements etc   thus  making up to all the analysis objects  enabled by the system     The arrow like surface markers help you navigate around the landmarks     4 Blue arrows define a passive selection     Yellow arrows indicate the selected objects  Their positions can be changed by dragging  the corresponding marker        The arrow turns when you place the cursor on it     Enter object name  please Annotate the landmark by right clicking it and  kz    selection the appropriate option from the popup  EE menu  Enter the name of the annotation and click  OK           Customize the view of the landmarks by right
42. 4 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p e  gt   Ortho System    2012 User Manual       All of the options described above may also be accessed by right clicking on the active  selection label  top  or image  bottom      3Shape A S 3Shape Inc  3Shape Asia   Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road 13  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com  Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual      Open  ent case  E Open pati    MHBUBREERE      z S  AL  Patient Selection   mi    Right view Left view Right buccal view    mnvi   8  Export to file    lt  Import from file   8  Export to CAMBridge    24 03 2010  24 03 2010    e ESE    E Open patient case    A 1  Patient Selection  d  S Jane Doe    g 3 John Doe    FF  Views  L   Open model set    New model set     4 Edit model set        New patient     d  amp  Refresh previews   B Export to file    24 03 2010  24 03 2010  14 38 25    Maxillary view       1 3 2 Open Model Set    In order to complete this step  it is required that there is a patient case created  see  chapter New Patient   Having opened a patient model set in the session window 
43. 6 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    The Virtual Setup function contains the four steps     1 4  Choose setup  2 4  Extract teeth    3 4  Set objects  4 4  Move teeth    The four steps are described further        Note  When you first click the Virtual Setup button  there appears an      IMPORTANT INFORMATION AND LEGAL DISCLAIMER window also shown below     gt  Please read the information carefully before proceeding     OrthoAnalyzer 2012 IMPORTANT INFORMATION AND LEGAL DISCLAIMER    The functionality of the OrthoAnalyzer    software allows you to manipulate a 3D visual  model of a patient   s dentition by dragging and moving individual teeth in the model   whereby you may explore how the visual appearance of the dentition may change if such  tooth movements are implemented     Please be informed that the OrthoAnalyzer    software does not in any way attempt to check  if any specific tooth movement or combination of tooth movements visualized in the  software is actually possible to implement on the patient in real life     Manipulations visualized in the software may not be possible to implement in real life  e g   because the teeth may not actually be moved as visualized  A visualization created in the  software of any tooth movements may also be inaccurate  e g  because such movements  if  implemented in real life  might cause mor
44. 6 2012 3Shape A S  All rights reserved 3sha pe  gt     Ortho System    2012 User Manual        OrthoAnalyzer    mS    Application    Models View Help    Patient ID    Patient SSN    Patient name    Patient address  Holmens Kanal 7  Patient city  Copenhagen                  Actual frame rate   8 8 fps  Achievable OpenGL frame rate  75 5 fps     A detailed description of these is provided in the following sections     2 1 Main Toolbar    The Main toolbar contains functionality relevant to managing the analysis and the modelling    processes   Item Action  zm Patient model set   Loads previously created patient model sets from the  E patient database     New session   Starts a new analysis session on a model set which is not    attached to any patient      3  e    Open models   Opens model s  required for inspection and imports them into  the system     Save session   Saves the current analysis session to default file     3Shape A S 3Shape Inc  3Shape Asia 19  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual       Export models as     Saves the current analysis session to the selected file        ea    Create virtual base   Starts the utility designed for the virt
45. 8 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    Application Models View Help             Vs Alignment for open model set Current workflow steps       Occlusion   amp  Setup maxillary model local origo   Alignment for open model set  Setup local origo on maxillary model  Setup occlusion plane    a Setup occlusion plane Preparation maxillary model  Preparation mandibular model    Preparation for maxillary model    a  RAN  DT DN aie A      A4    lt      ds Ae Dal D  a    TEL  W         a       3Shape A S 3Shape Inc  3Shape Asia 116  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    
46. 9 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    1  2   The points placed on the cross    section are automatically attached to the    4 beige contour of the cross section   so BF mm        3   The system automatically builds the     right angled triangle using the selected   measurement line as its lateral face    4   The measurements of the other faces   of this triangle are also displayed on the   cross section     To clear the measurements made  click    the   button        The 2D Cross  section window  enables area  measurements  on both sides of  the  measurement  line     Click the  Measure Area    EN button and    place the cursor  over the area  you want to  measure  The  area becomes  colored yellow  and its value is  calculated  automatically        Along Dental Arc allows to create the cross   section along the dental arc with the spline   1   shown in green  going through its  center  The centre of the cross section plane  is marked with a red cross as shown on the    image   Lower jaw   turns on the cross section for  the lower jaw     S n   Er i  Upper jaw   turns on the cross section for  the upper jaw        3Shape A S 3Shape Inc  3Shape Asia 45  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone
47. B 5 16     Korkhaus_   5 48     Korkhaus B_ideal 47 00     Korkhaus C ideal 54 50     Korkhaus B B_ideal di     36 854          3 3 2D Cross Section         You can open the Cross section function from the Visualization toolbar to access all          2D based planes  measurement and symmetry tools     3Shape A S 3Shape Inc  3Shape Asia 36  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual                  SE EE  ee dae eae fpf tS GE  DR a elle EH EE ER a    HN  HHN a EH       CU                           Ria          tees J    ereen ps    Ries Bag Ep  Sa tcesageaenms    ffe     44088    louse    h al   TITT T   TT    Pet    Measuring buttons  Cross section plane   2D Cross section preview  Manipulation buttons    SCH ds E Ss    3Shape A S 3Shape Inc  3Shape Asia 37  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual       Step 1  Draw the Cross section plane    
48. Clear all removes the color marking     e hed Inter proximal reduction   Stripping     Allows you to cut the selected tooth according to the parameters you enter    In the Inter proximal reduction section you can use the Automatic section to align the  selected tooth automatically  Edit the IPR Mesial and IPR Distal parameters manually in  the required fields  Otherwise  you can click the Calc button and strip the selected tooth  automatically     3Shape A S 3Shape Inc  3Shape Asia 62  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual _ _ S       If you want to perform manual stripping  adjust the Tool width in the appropriate edit box   Select the desired area by clicking and holding the Ctrl button  Thus you mark the stripped  section in transparent grey    The  saw  mode if checked  allows you to emulate a straight tool  while the simple mode  allows you to mark the curved surface as well     After you have selected a single tooth and have performed some changes  on it you can use the green arrows in the left upper corner to Undo Redo  the changes        Click Apply to apply the changes  You can go back and forward within the steps with the  green arrow b
49. Control Panel manual  and chosen from the Tooth movement  Constraint list  These constraints can be associated to tooth biomechanical and  morphological rules  or to the mechanical properties of selected appliances     While editing the Movements parameters it is possible to move the selected tooth further  then the allowable limit if the    visual feedback only    was selected in the Ortho Control Panel   In this case you get the popup warning message  Right click it and select the appropriate  option from the popup menu     Details    Correct  Correct All    Ki       e     Attachments    Places the attachments to the selected tooth  To place the Attachment follow the next  steps     1  Select the tooth with the single click  the tooth turns blue     2  Select the Group and Attachment type from the drop down menu in the Attachments  tab that is set in the Control Panel  For more information see the Hearing Instruments  Control Panel manual   You can also select the Orientation of the tooth from the given  drop down list  Click on the tooth once again to place the attachment     3Shape A S 3Shape Inc  3Shape Asia 60  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 Us
50. Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    3shape gt     OrthoAnalyzer 2012       User Manual    3Shape A S 3Shape Inc  3Shape Asia  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    Table of Contents    PAC    EG 3  PGS E Star ed gie EE 4  1 1 EXecuting b  ie ge TT EE 4  1 2 Creating a NeW  Database EDY gea 5  e eM  NEW PP En eren r ee ewe ew ee ee ee eee ee ee eee E EEEE 5  1 2 2 New Model ET 6   1 3 Re  t  rning to the DataDase GNU e EE 7  1 3 1 Patient Model Set EE 7  15 2 ODEN MOCC  KEE 14   1 4 Starting an Independent SESSION vicccccccccccccceeeeeeeeeeee eee HEHEHE HEHE HEHEHE HEHEHE EE SeEEeeS 15  1AT NEW SESSION NEE 15  LAZ ODON Tel ee ee ee ee 15   2 OrthoAnalyzer User Interface d ca ee 18  2a Maln VO OUD Ab E 19  2 2 Using the Mouse and Keyboard    NNN NNN NNN 20  EE WE gen ee e EE 21   ER Rue ged ou hee eee ee ee ee ee ee 24  E End ei Du e EE 25  3 2 3D Measurements and Custom Analvele NNN 31  Be 2  GOSS SOCOM EE 36  APUN egene En EE 47  ere EI e e EE 48  Ae NCC HS FOUN  EE 49  4 1 2 Alignment for Open Model Get    52  Ao Villa 3 D e EE 53  Ae  CONRO e e EE 66  4 2 1 Setup Maxillary Model L
51. Draw the red line  where the cross section will be by holding the left key of the mouse   Single click at the line creates the cross section   It is possible to set the cross section by placing three points     3Shape A S 3Shape Inc  3Shape Asia 38  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    br Step 2  Move the  cross section plane  with several elements     1   The control point  located on the blue circle  defining the plane moves  the plane back and  forward without changing  its slope    2 4   Change the slope of  the plane along the cross   section plane which is  perpendicular to it  To  visualize this additional  plane  activate the blue  circle by clicking on it to  make it turn beige  As  long as the beige circle is  kept pressed  the system  displays the grey circle  with its own brown  control point  While  pressing the mouse  button  drag the control  point to change the slope  of the cross section  plane    3 The central point  moves the plane around  the model leaving the  slope of the plane  unchanged    5  The control point  located on the plane  corner rotates the plane  clockwise and anti   clockwise without moving  it or changing its
52. EER directly in the tab by clicking on the desired field  Click the  Rotation 0 deg Teeth movements overview link to get a full report on the  Left Right D mm teeth manipulation    Forward  Backward Oram   Extrusion Intrusion O mm   Tooth long axis angle undefined E    Indination Extrusion Intrusion  Forward Backward    Teeth movement Constraints   0 0 mm    Table    2 1mm 0 5 mm  iimm  0 4mm 0 4mm  0 1 mm  0 0 mm          e    IMovements  3Shape A S 3Shape Inc  3Shape Asia 59  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Allows to move the selected tooth to simulate the treatment  3 Methods are available for  teeth movements     Select the tooth and use the mouse to freely move the tooth     Select the tooth and use the keyboard arrows to move the tooth     Or manually edit the movement parameters in the respective table fields  Inclination   Angulation  Rotation  Left Right  Forward  Backward  Extrusion Intrusion     o  Uo a  eg  Hint  Use the Ctrl key of the keyboard to select and move groups of teeth them    d synchronously     Movements constraints for the treatment simulation can be set in Control Panel  for more  information see the Ortho 
53. Mail  info 3shape com  Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Open patient case    SUBUBOERS          Patient Selection    ko E ZS  G      SS Open model set i Right view Left view Right buccal view         New model set     y Edit model set        New patient      e EE al vi Front view  i gt  Export to file   A Import from file    gt  Export to CAMBridge       E Open patient case     813  ef  ef efiatiafis    s    Patient Selection      2 Jane Doe             Small previews    2 s   ze  a SP Open model set  KW E New model set      AF Edit model set       New patient     a Refresh previews    gt  Export to file   A Import from file  i 3 Export to CAMBridge Mandibular view Maxillary view          e Throughout advancing to the last node of the selection tree  the system assists you  in tracing the order selection  as well as in managing the active selection with  available options  There are two sections in the window which perform this task     3Shape A S 3Shape Inc  3Shape Asia 10  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p    gt 
54. Mandib  6   Ratio    Mandibular E width    Use calc  ratio    Use calc  ratio  Calc  maxillary 12 width  Calc  maxillary 12 width      66    Overall Bolton Analysis  Ideal ratios     Masilla 12 width  Mandibular 12 width    Use calc  ratio    Use calc  ratio  Calc  maxillary 12 width  Calc  maxillary 12 width       Bolton analysis    1  Overall analysis  twelve width   2  Anterior analysis  six width     Step 3  Apply the settings for the Space Analysis tab  Click the Space analysis tab to view the table data available for this type of analysis     This section provides two types of space analysis   the Moyers and the Tanaka  amp   Johnston table analyses for both the maxillary and the mandibular arches  This is done to  predict the orthodontic manipulations with the spaces indicated in the setup section of the  analysis process     The Standard Moyers table is selected by default  To switch to a different type of the  standard Moyers table  select it from the Standard Moyers Table drop down list  This is  customizable in Ortho Control Panel     Having calculated the sums of the incisors  canines and premolars separately  the system  yields a set of Moyers and Tanka  amp  Johnston values for the Total space required     3Shape A S 3Shape Inc  3Shape Asia   Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road 87  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com  Phone  45 70 27 26 20 Phone   1 908 219 46 41 Ph
55. Ortho System    2012 User Manual    The functions in the Analysis tab are assorted  according to the operations executed in the previous  steps  they typically rely on the selections and  definitions made in the preceding sections  The tab  contains the following steps        Provides calculations for arch lengths based on the     selections made in the Configuration section of the  L   Dental arc analysis Function panel and enables the creation of an ideal arc  Shape to be used for the treatment   Provides detailed analyses of the various orthodontic  data for both maxillary and mandibular casts   8   comparing them with the standardized values tables  Analysis reports pre set in Ortho Control Panel  This involves inspecting  the tooth widths  space  the anterior and Bolton ratios     5    Provides the overbite overjet measurements for easy    sy     rz Overbite Overjet diagnostic    k     Allows to present customized analysis    a Questionnaire   WW Creates an analysis report based on the analysis data   SEA repari ready to print     Visualizes the occlusal distances in the model set  according to the color scale applied to the virtual casts     The final functional tab Model Set Compare assists in  effective comparison of two model sets attached to one  patient  The tab contains the following steps        gs Enables immediate comparison of model sets  Compare model sets visualizing the two simultaneously    4p   Aligns upper models belonging to different model sets     Max
56. Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Step 1  Click   B open models in the Main toolbar  The empty Open models window  pops up suggesting browsing for a model in  dcm  wrl or  stl formats           Open models x General   Select either of the 2 models to  General    Preview maxilla   3 automatically locate the    complimentary model and open    the model set   W  Show preview       Decimate db models to    200000  triangles     gt  gt     Maxillary model    Mavillary model filename        E Maxillary model   WEE Preview maS Choose a maxillary model only     Number of vertices  to load into the system     A3    A3    Mandibular model    Mandibular model filename        Browse    Number of triangles  Mandibular model     Number of vertices   Choose a mandibular model    only  to load into the system              Step 2  To browse for a model set in the Orthodontics Control Panel  use the Browse  buttons under each of the blank fields  The default path to the folder with files of the patient  database is C  Program Files 3Shape OrthoData     e You may browse exclusively for the maxillary or mandibular models using the  Maxillary model or Mandibular model fields of the window    e If both parts of a model set are required  then it is possible to
57. Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    4 3 6 Occlusion Map    The Occlusion  map enables  visualization of  occlusal distances  in the model set   Click the    d Occlusion    map button on  the Analysis tab   The system will  automatically  color the virtual  casts according to  the Color scale  displayed on the  right of the  session window     The areas of the  teeth closest to  the occlusion  surface are  marked red   gradually  changing to the  colder color  palette  as the  occlusion distance  becomes larger     4 4 Model Set Comparison    Model Set Compare       The Model Set Compare section of the Function panel  enables detailed simultaneous analysis of the two model  sets belonging to one patient        This section includes     Compare model sets   Maxillary model registration  Mandibular model registration  Difference map for two model sets                 These steps are described in details below     3Shape A S 3Shape Inc  3Shape Asia 96  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved    Ortho System    2012 User Manual    3shape gt     4 4 1 Compare Model Sets    Open patient model set    Search result  
58. ally creating  an arch  and four points for Bezier and Custom as shown on the image     To change the shape of the spline  change the position of the selected control points with  the help of the cursor  For the custom made ideal curve  the original spline is marked green   whereas the current spline turns blue  for comparison as shown on the image    Click Clear to remove the arch  Click Copy opposite arch to get a copy of the arch from  the opposite cast  Select the Show opposite arch checkbox to show hide the arch on the  opposite cast     ih  Hint  Using the 1 1 real scaling Aii of the Visualization Toolbar  you can easily  replicate a physical arch wire by drawing it on screen with the Custom Arch  option        3Shape A S 3Shape Inc  3Shape Asia 84  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p    gt   Ortho System    2012 User Manual    If necessary  define the distance between  the ideal curve and the bracket in the  Bracket offset box  The Bracket offset  value corresponds to the thickness of the  orthodontic appliance  e g  the brackets    whereas the Offset wire arc length  corresponds to the length of its metal wire   Entering both positive and negative values  is possible in Bra
59. an Hint  Please refer to the chapter 4 for more information about each of the tools  included in the Function panel     Action    The first part of the toolbar is the Manipulation tab  It  includes the following steps           E oeciusion Helps realign the upper and lower virtual casts    d  Helps align the upper and lower virtual casts for the  Alignment for open open model to make the visualization and manipulation   model set of the model more convenient     Treatment simulation via virtual setups     The second Configuration tab assists with indicating  landmarks on the virtual model set and contains the  following steps        ei Specifies the point on the model which will  Setup maxillary model subsequently serve as local orientation point from  local origo where the coordinate system axes originate     Be Setup occlusion plane Sets up the occlusion plane for the model set     Definition and segmentation of individual teeth for the    Tissues for maxillary side     maxillary model    KE    Definition and segmentation of individual teeth for the  Preparation for mandibular side     mandibular model    3Shape A S 3Shape Inc  3Shape Asia  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   
60. ape    The software automatically opens the  Virtual base dialog guiding you through  the main steps  Define Cut  Fit Base  and Create Base    Ei   Upper Lower base   SEI    _ icons toggle the  visualization of the  corresponding models  for better overview   Previous  Next  operations navigation       buttons   A Define cut   used to  Ba draw the cut or   A Fit base   adjusts the      base   d    Create base   creates a    Vw new base     Base model type    Select the desired base model type from  the drop down menus   The virtual  models are set up in the Feature Settings    gt Template base models of the Ortho  Control Panel     3Shape Asia 108  Room 1205  No 738 Shangcheng Road  200120 Shanghai   Phone   86 138 183 38960    Mail  info 3shape com  Web  www 3shape com       Copyright 2006 2011 3Shape A S  All rights reserved    3shape gt     Ortho System    2010 User Manual      Virtual Base    Teeth models    Select base model     _ Full  upper   base 1    Full  lower   base 1      ABO max    ABO man  Tweed max  Gd Tweed man    Ricketts man    C  D p arch_max       e Define cut       Incorrect splines can be removed by clicking  the corresponding Clear splines buttons in  the Virtual base dialog     From the right click menu options of the  cursor positioned over the cutting spline you  can Add new or Remove indicated spline  points  Clear spline or use Fast edit function  to correct the spline    3Shape A S 3Shape Inc    Holmens Kanal 7 571 Central Ave   Suite 109  DK 106
61. are z            ha          Local Origo Setup         to set up local origo    A Pick point on the model  and coordinate system             Actual frame rate  9 7 fps  Achievable OpenGL frame rate  17 2 fps     4 2 2 Setup Occlusion Plane    The Setup occlusion plane step allows you to place the occlusion plane that is used  for the 2D measurements at the Analysis objects step  Custom spline 2D  Measure  2D and Distance 2D            Note  The occlusion plane need to be predefined to be available as default  position for the 2D cross section analysis  section 3 3     It is also required for the calculation of the tooth long axis at the preparation  stage   section 4 2 3     To setup the plane  please follow the hints on the form  see the image below   You will be  asked to place 3 landmarks on the teeth number 3  8 9 and 14  or equivalent depending on  the chosen tooth numbering system      3Shape A S 3Shape Inc  3Shape Asia 68  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual       Overview a  D Please set landmark  14           Clear   OK      e        et    When done  the occlusion plane appears on the cast     Occlusien plane    ds       Note  All pla
62. ation  and click the Save    button           6 2 Open Patient Model Set in Virtual Base       The aim of the kal  Open Patient Model Set in Virtual Base step is to model the virtual  base for a model or a model set belonging to the patient database  The task involves  completing of the three steps  Open Models  Virtual Base and Export Models  similarly    3Shape A S 3Shape Inc  3Shape Asia 112  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2011 3Shape A S  All rights reserved    3shape gt     Ortho System    2010 User Manual    to the described in the Create Virtual Base chapter with the only difference being the  automatic navigation to the Open patient case dialog where the user looks for a model set    within the available patient cases     Open patient case  gt                                  et 4 ID  Jane Doe  E  9 ID  John Doe    e ZE               Jane Doe     s5 Holmens Kanal 7       EIBBEREE    m       Model set comment Model set c    7 Customized Workflow Wizard    3 24 2010       As a new feature in OrthoAnalyzer 2010  you can create a number of customized workflow  wizards with predefined operational steps  This cleans up the software interface and  organizes steps and operations for your own use  The supplied OrthoAnalyzer
63. ation center of the selected tooth  Select    show teeth  only    and choose the tooth from the overview or directly on the 3D model  Select the  rotation center with your mouse and drag it to adjust its position         gt  The Sculpt option becomes available at the last step  It allows trimming the  teeth after the separation  It is possible to remove surface on the selected  area           3Shape A S 3Shape Inc  3Shape Asia 80  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Click the Adal   be in the Wax knife settings  section to add some material to the scan  The target  area circle is marked red     Select the Remove Lej button to delete extra    material or click the Smooth ry button  The target  area circle is marked blue and green respectively   Adjust the Radius and Level of the marking circle by  pulling the corresponding slide bars  It is possible to use  the already customized settings from the list of six  variants  Activate the desired mode by clicking at its  number in the list  To change the setting for the mode  set the parameters in the Wax knife settings section and    click the Save    button  Mark the Show target area  checkbox to d
64. cified folder  the Merge attachments with models   checkbox to export models with attachments     Save models as     Save madels as        Save upper model Save occlusion as      Upper model filename     c  programdata  3shape orthodata 2011 1 beta 2001 1 2001_1_   Browse    Save virtual setup as           E test  Save lower model Upper Model C  ProgramData 3Shape OrthoData 2011 1     Lower model filename  Lower Model C  ProgramData 3Shape  OrthoData 2011 1     c  programdata 3shape orthodata 2011 1 beta 2001 1 2001_1_   Browse Model set EE    Save occlusion as                 Save virtual setup as    y Merge attachments with models    Duplicate model set      Duplicate model set        The Save occlusion as    option saves the Duplicate model set saves the copy of the  occlusions  project on the current stage        3Shape A S 3Shape Inc  3Shape Asia 65  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Save models as     Save models as       Save occlusion as     Save occlusion as           Save virtual setup as     Name of new occusion  05 09 2011_14 58    Duplicate model set       ID of new model set 1_duplicate    Save virtual setup as        Dup
65. cket Offset     Compare the Ideal arc length  blue  and  the Offset wire arc length  green   values  to define the treatment  measurements  if any  If the offset value  equals zero  then the lengths coincide  In  the example above  the original length of  the upper tooth row spline is 103 89mm   whereas the offset value of 2mm changes  the offset length to 109 63mm        Click OK to finish Dental arc analysis     4 3 2 Analysis Reports    The option Analysis reports is provided to enable effective  and versatile analysis of the models  OrthoAnalyzer provides  three officially recognized analyses  Tooth width analysis   Bolton analysis and Space analysis  The option of  comparing both  the maxillary and mandibular teeth rows  with the pre set  standard values is enabled with the data  imported into the Ortho Control Panel        Click the    Analysis reports button in the Analysis tab to open a window containing the  Overview section illustrating the information presented in the three dental analysis tabs  In  the Overview window  the teeth of the maxillary and mandibular right quadrants are  marked red  the teeth of the maxillary and mandibular left quadrants are marked green and  the missing teeth are marked grey     br Step 1  Customize the Tooth width analysis settings   The Tooth width analysis tab appears in focus automatically when you open the Analysis  reports  it contains the data for this type of analysis as shown on the image below  To view  a different type of th
66. ct                      Properties   3Shape A S 3Shape Inc  3Shape Asia 33  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual       Indicate the measurement by two  landmarks replicating a physical  calliper  Customize the  measurement by right clicking  the landmark and opening the  popup menu        To make this measurement  create the  line  gt place the landmark at the area  you want to make the measurement  from  gt click at the selected line            Distance to plane    To measure the distance to plane create a plane  gt place a landmark on the area you want to  measure the distance from  gt click the green border of the plane or the annotation  if there  iS      3Shape A S 3Shape Inc  3Shape Asia 34  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual    3Shape A S   Holmens Kanal 7  DK 1060 Copenhagen K  Phone  45 70 27 26 20       3Shape Inc    571 Central Ave 
67. cted teeth will  turn red  in the session window and in the Overview form   To unselect a tooth  left click on  it once more  Click Apply to perform the extraction     Click either the   Next step or Y set objects button to move to the next step     3Shape A S 3Shape Inc  3Shape Asia 56  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p e  gt   Ortho System    2012 User Manual       Please  click on the tooth   which you would like to  extracti    Setup  12 05 2010 15 28 14             Subsetup      tep 2 4  Extract teeth       4 1 3 3 Set Objects    At the third step of the Virtual Setup  the Set objects step  you are asked to click on  S teeth to define a bracket position            Click on a tooth to setup a  bracket     Setup  select setup           Click on the teeth one by one  the active tooth turns blue  and place the yellow points  on each of them    To clear the bracket from the selected tooth  click the Clear button  to remove all  brackets  click the Clear all     3Shape A S 3Shape Inc  3Shape Asia  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road 27   DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com  Phone  45 70 27 
68. different effects than as shown in the  visualization created within the software     Furthermore  the software does not contain any functionality attempting to check whether  any such real life implementation attempt might result in damage  e g  to the patient   s  teeth or jaw  Any treatment attempt to implement on a patient a tooth movement or other  manipulation visualized by way of the software should be planned and made only by a  dental professional having with due diligence assessed whether the visualized manipulation  can actually be implemented without causing damage to the patient     The risks pertaining to any such treatment attempt shall be assumed entirely by the person  carrying out the treatment     3Shape A S disclaims any and all liability for the results of any treatment attempts made on  the basis of the visualizations generated within the OrthoAnalyzer    software     3Shape A S 3Shape Inc  3Shape Asia 3  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual       1 Getting Started    This section describes the principles of managing the orthodontic models in OrthoAnalyzer       The chapter is divided into three parts  the first part is about a
69. e 10 52 mm  cursor over     the area and k   see its value  displayed  while the  field turns  beige             To move to the next step  you can click either the   Next step    Define cut or  Next buttons     4 2 3 2 Define Cut    At the Define cut step you can adjust the cut spline or recreate it manually  The  _    program automatically creates the spline for each tooth based on the mesial distal  points placed at the previous step     To adjust the spline  click desired tooth in the Overview window to activate it  The control  points of the active tooth turn green from blue  Click on the control points  turn yellow when  active  and drag them with the mouse to form the desired spline  Select the Move close  points synchronously checkbox to move simultaneously the control points that are set  close to each other  When you need to delete a control point from the spline of the selected  tooth     right click on it and select Remove from the appeared menu     To create the spline manually or to edit it using the fast edit mode  you can use the buttons  in the upper left corner of the session window   Segment tooth manually and Spline fast    edit mode    3Shape A S 3Shape Inc  3Shape Asia 73  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road   DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 201
70. e or different effects than as shown in the  visualization created within the software     Furthermore  the software does not contain any functionality attempting to check whether  any such real life implementation attempt might result in damage  e g  to the patient   s  teeth or jaw  Any treatment attempt to implement on a patient a tooth movement or other  manipulation visualized by way of the software should be planned and made only by a  dental professional having with due diligence assessed whether the visualized manipulation  can actually be implemented without causing damage to the patient     The risks pertaining to any such treatment attempt shall be assumed entirely by the person  carrying out the treatment     3Shape A S disclaims any and all liability for the results of any treatment attempts made on  the basis of the visualizations generated within the OrthoAnalyzer    software     4 1 3 1 Choose Setup    _  The first step Choose setup offers you to create new setups  scenarios  and  uf subsetups or choose the existing ones  Please follow the hints written in green on the  form as shown on the image     3Shape A S 3Shape Inc  3Shape Asia 54  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a
71. e standard tables  select it from the Standard tables drop down  menu     The Tooth width analysis tab presents a list of the actual individual tooth widths  compared to the standard average values in order to determine the locations and amounts  of the tooth width discrepancies  New standard tables may be imported into the Material  settings of the Ortho Control Panel     SD   Aci       ual TW   Average TW   Comparing the actual and the average tooth width   TW   tooth width   values  the user can calculate the standard deviation  between them  marked SD on the graphs      3Shape A S 3Shape Inc  3Shape Asia 85  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    Analysis reports    Overview  Standard tables   Default      Hl axilla    Actual Tooth Widths  mm       Tooth  Let    Right   D os m cn P co P        Hl andible    Actual Tooth Widths  mr       om Un dm fu M    Tooth  Lett   Right     a  j       Tooth width analysis      Step 2  Fill in the Bolton analysis tab  Click the Bolton analysis tab to view the table data available for this type of analysis     The red spline in the Overview window is divided in three sections  It highlights the six  front teet
72. el set for  modeling  whereas  in the second one opens the baseless model set within the patient  database     6 1 Create Virtual Base    _ This functionality creates virtual base for a model or a model set not necessarily  ey belonging to the patient database    The task is executed in three steps  Open models  Virtual base and Export  models as        e  J Open Models    Click the Create Virtual Base button to automatically go to the Open models window and  load the required models with the Load button        3Shape A S 3Shape Inc  3Shape Asia  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Open models    General A Preview maxilla    Show preview     Decimate db models to  triangles       Maxillary model    Mavller model filename     Preview mandible    Number of tangles     Number of vertices     Mandibular model    Mandibular model filename     Number of tangles     Number of vertices        3Shape A S 3Shape Inc  3Shape Asia 106  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Pho
73. entral Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p    gt   Ortho System    2012 User Manual    Open l            Lookin  1  AndreasFriedrich G t em       i   Name   Date modified Type Size  a   Recent Places    No items match your search     Ortho System import files   3sz     c  Selecting a patient case adds two new buttons designed to help with managing an  individual model     Open model set button produces just the same effect as a double left click on   KR the selected model  i e  it submits the selected model to the analysis process  opening it in the session window    Edit model set    button opens the existing patient case information form and     Suggests editing the fields which were previously filled in  Click Change to save   changes    Refresh previews refreshes visualization of the settings changed in the Ortho  Control Panel     18 Export to CAMBrigde lets you open the preview of the selected model     When you select the Export to CAMbridge  gt  button you can observe the preview of the  selected model in the Model preview window     3Shape A S 3Shape Inc  3Shape Asia 12  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 0797
74. er Manual       Allows to squeeze stretch the Positions the attachment deeper in the    width 4  model    2  Geen EE ne rene 5  Allows to squeeze stretch the length    3  Moves back and forward    Mark the Reverse direction checkbox to turn the attachment into the opposite direction     Se  D a  A  A    e   Distance map    Shows the selected teeth in the color scheme displaying the distance to the antagonist and  neighboring teeth    It is possible to edit the settings for the Distance map in the submenu  Mark the Show  Distance map and the Show scale checkbox to display the Distance map color scale and  the distance map respectively  It is possible to edit the Max  value of the color scale  manually  Use the Set all button to show the Distance map for all the teeth  This option  can be turned on during the other stages of movements so you can see the possible  collisions of the neighboring teeth     3Shape A S 3Shape Inc  3Shape Asia 61  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    0 75 mm    0 60 mm    0 45 mm       This option can be turned on during the other stages of movements so you can see the  possible collisions of the neighboring teeth   
75. essing Apply and  Model Visibility     transfer to the Single view     Reference Both Compare  7 The Model Set Compare form  image to the left  is  described in the Compare Model Sets chapter        On completion of the upper model registration  click OK  to save the results and leave the step           4 1 3 Mandibular Model Registration    This step assists the proper alignment of the lower models belonging to the model sets  chosen for comparison  This is a necessary pre requisite for effective and informative  analysis of the differences between the model sets    w    Click the Mandibular model registration button in the Model Set Compare tab to    open the Registration form  The rest of the registration process is similar to the one  described in Maxillary Model Registration chapter        4 1 4 Difference Map for Two Model Sets    The Difference map for two  model sets compares shape  differences between the  reference and the examined  model sets visualized with the  help of the color scale  The  distance between the surfaces  of the two model sets is  measured yielding positive and  negative deviation values     Click the   Difference map  for two model sets button in  the Model Set Compare tab   The system will automatically  mark the virtual casts according  to the Color scale displayed on  the right of the session window    The areas of the model set  rising above the reference  model are marked red gradually  transiting to green  as the  distance between the model
76. fo 3shape com  Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p    gt   Ortho System    2012 User Manual    When clicked  the Single view button changes to the Dual view one and displays two model  sets next to each other  The Choose button opens Open patient model set window to load  another model to compare with if needed        4 1 2 Maxillary Model Registration    The aim of the Maxillary model registration step is to properly align the upper models of  the model sets chosen for comparison  This is a necessary pre requisite for effective and  informative analysis of differences between the model sets     Step 1  Start the maxillary model registration  process       parts to use and press Apply   S   jJ  or Ok to perform the Click the Maxillary model registration     button  alignment  in the Model Set Compare tab    Overview a Choose the best option for the model alignment in the  Ee appeared Registration form   surface 3 point E  e Surface 1 point  Indicate single corresponding    Dret Seem e Reset   points on each model for alignment and  optionally select the surface to align with the                         K     help of the Selection Tools    zen   e Surface 3 point  Indicate three corresponding  points on each model for alignment and  optionally select the surface to align using the  Selection Tools    e Direct 3 point  Indicate three corresponding  points on each model for alignment  This method  does not use the surface infor
77. ghai Mail  info 3shape com  Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com          Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual    3shape gt        3Shape A S   Holmens Kanal 7  DK 1060 Copenhagen K  Phone  45 70 27 26 20    Overjet measurements    3Shape Inc    571 Central Ave   Suite 109   New Providence  New Jersey 07974  Phone   1 908 219 46 41    3Shape Asia   Room 1205  No 738 Shangcheng Road  200120 Shanghai   Phone   86 138 183 38960    90    Mail  info 3shape com  Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i  e  Ortho System    2012 User Manual       4 3 4 Questionnaires    For a better presentation of the customized analysis and the  implementation of scoring systems  you can now use the  questionnaire located under Analysis   gt Questionnaires        This new feature allows you to present your customized  analyses in a more user friendly manner using bitmaps   notes  screenshots etc     4 3 4 1 Using a Questionnaire       1  To start the analysis  select the Questionnaires de button in the Analysis section of the  Function panel  It will open the Questionnaires window     This section presents an example of the PAR Scoring questionnaire  though any analysis or  scoring system can be configured with the existing tools     Note  Prior to working with a questionnaire in Ortho Analyzer    you have to  configure it in the Ortho Control Panel
78. gigiva with the splines under the teeth that will not be corrected during the step     br Step 2  Perform additional actions with the selected tooth    At the right top corner of the session window you will find the  Tooth panel with different visualization options  By  selecting unselecting the first five checkboxes you can  show hide some specific parts of the model for better  visualization     Tooth panel Use active tooth rotation center     When checked  rotates  31 Show all the model using the rotation centre of the selected tooth   Show selected tooth only OR  Show original for selected tooth   When checked  recreates  a shadow of the selected tooth in its original position     Show all without selected tooth  Show teeth only    Show jaw without teeth 7  Show Mirror for selected tooth     When selected  shows a    Make non selected teeth transparent f i i  i mirrored image of the selected tooth along the sagittal plane     Show neighbour teeth only    Show original for selected tooth Show tooth markers   Shows hides the markers on the  Show mirror For selected tooth teeth   EE The Movements tab contains information about the operations    Movements   26 performed on the selected tooth and the movements buttons      The number near its heading indicates the number of the tooth  you are currently working with  After you have rotated or  moved the tooth  the corresponding values appear in this tab       ere de showing exact measurements  These values can be changed  EEN B
79. h and the twelve teeth closest to the labial surface on each of the models for the  anterior and the overall Bolton analyses correspondingly  see the image below      The tables automatically shown in this tab are reproduced by default  Specific to the patient  model of an individual  the Anterior and Overall ideal ratios are customized and easily  imported into the Ortho Control Panel     According to the example in the tables  the ideal AR for the ethnic group to which the  patient belongs to equals 0 77 whereas  its ideal OR equals 0 91     Based on the ratios of the maxillary and mandibular six and twelve widths of the current  model  the system calculates the AR and OR deviations from the standard ratios for the  given ethnic group  It is possible to predict the necessary measures to adjust the structure  of the whole teeth row in order to provide the orthodontic treatment     3Shape A S 3Shape Inc  3Shape Asia 86  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    Analysis reports    Tooth width analysid  Bolton analysis   ene    Standard Moyers Table   Default       Anterior Bolton Analysis    Overview    Ideal ratios   Cale  maxillary 12 width Maa 6   
80. he    model       OrthoAnalyzer lets you save as many 2D planes as you require  Click the Save plane  button to open the Confirm popup window  Select Save as new plane to proceed  Give  the Name to the new plane and click Save  The new plane will be displayed in the drop  down menu in the Standard planes option     Confirm A F F  A    Name Cross section Plane 1            3Shape A S 3Shape Inc  3Shape Asia 40  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    EE basa After you have saved the planes  you can select  ie them from the drop down menu in the Standard  Cross section Plane 2 ee  j planes option or for default positioning in the  Cross section Plane 3 virtual articulator   see the Articulator section            fr Step 3  Make the 2D measurements    Use the buttons at the top of the screen to apply different 2D measurement on the cross   section     Length measurement requires two points  Measures length from point to  point        It is possible to customize the settings  of the measurement  Right click it to  open the popup menu and select  Properties     ela    E  5       Select the color of the measurement  from the drop down menu  You can  adjus
81. he cast  opposite to it  see the image below     Thus you can compare the two planes and align the    models as required        Set points  E  Show intersection                   Modification x  Trans box     Amah  Translation step 0 20   mm   Rotation step 2 00    deg    Plane grid x    d         Show plane grid            Select the Show plane grid checkbox to place the  points on the cast to create a plane grid  please see  chapter Occlusion for more information            4 1 3 Virtual Setup       by Virtual Setup is a feature simulating the orthodontic treatment in OrthoAnalyzer     In order to move the teeth to simulate a treatment  a segmentation cut is automatically  Suggested and performed when the teeth are defined at the model Preparation step as  described in Preparation for Maxillary Model chapter  otherwise  you will get the following  warning message for unsegmented teeth when the Virtual Setup button is clicked        Warning    T There are no teeth models in the model set  Please  separate teeth in the setup Features       At the Virtual Setup step  you can create different setups and subsetups with the teeth  being extracted  moved etc  compare the created setups when desired and obtain a precise  summary of all teeth movements     3Shape A S 3Shape Inc  3Shape Asia 53  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 2
82. ick the  Spline fast edit mode button  Click and draw the new part of the spline that  needs correction and the program will adjust the spline     3Shape A S 3Shape Inc  3Shape Asia 75  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual       When you want to remove the preparation information from a tooth  click on the tooth in   the Overview window and click the Clear button  The Clear all button removes the   preparation information for all teeth at once    Click the Find hole in the model button to identify the holes between the teeth for     x better separation  Select the tooth with the holes  click the section you want to  place the spline on and click the Find hole in the model button  The separating   splines are placed           3Shape A S 3Shape Inc  3Shape Asia 76  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    Su    After you have
83. illary model of the same patient for comparison    registration   A4 i Aligns lower models belonging to different model sets   Mandibular model of the same patient for comparison   registration    bw  CN    d Compares shape differences between the reference      Difference map for two   2nd the compared model sets with the help of a  model  sets detailed color scale     4 1 Manipulation    The aim of this step is to set the occlusion for the casts and  create the virtual model setups        The Manipulation tab contains three steps  Occlusion   Alignment for open model set and Virtual Setup  These    3Shape A S 3Shape Inc  3Shape Asia 48  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    steps are described in details below     4 1 1 Occlusion    Ak The Occlusion step helps to align the upper and the lower virtual casts     Step 1  Open the Occlusion option    Click the Occlusion button on the Manipulation tab  Follow the hints provided in the  dialog box below       Step 2  Edit positions of the virtual casts in relation to each other using the  following options     e Trans box     1  Click on either the upper or lower casts to visualize the corresp
84. isplay the marking circle        It is possible to Undo  1  Redo  2  the last operations   Click the black arrow to observe the history of your actions   Click OK to save the changes           dd material  2        Undo all  4     You can use the Difference map to observe the changes you  perform in color  Click the black arrow to open the Difference  map options    Show bands   Makes it easier to see slices on difference map  with the same deviations    Show legend   displays the Co or scale     Show bands  Show legend          4 2 4 Preparation for Mandibular Model    Ei step defines the composition and segmentation of the  tooth row of the mandibular model  The workflow is similar to the    described in the Preparation for Maxillary Model chapter        3Shape A S 3Shape Inc  3Shape Asia 81  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual       This functional tab serves the purpose of comparing  particular patient models to statistically obtained ideal  deviations in order to plan the treatment accordingly        The Analysis tab contains six steps  Dental arc analysis  Analysis reports   Overbite Overjet  Questionnaires  Generate report and Occlusi
85. ize with  the green points of the bounding box  Click and hold the mouse button to drag the bounding  box to the required position     The following parameters of the base can be modified   Show Virtual Base      toggles visualization of the  virtual base     Show Virtual Base    GI  Scale symmetrically Curvature   100 Gi    Decimate base to i  sofsiin  Dist  between bases 39 0 fal mm     Offset mm        Scale Symmetrically      sets whether the bounding  box is scaled symmetrically  when dragging by the green  points     Decimate base to    specifies the decimation  amount of the base triangles   see image below         Curvature   sets the amount of curvedness for the base model along the sides  see image  below      Dist  between bases   Specifies the distance between the maxillary and the mandibular  bases     Offset   specifies the distance between the initial shapes of the base and the baseless    model     IMPORTANT  if the cutting spline is not contained in the blue base model at the  Fit Base stage  the combined 3D model cannot be generated        3Shape A S 3Shape Inc  3Shape Asia 110  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2011 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2010 User Manual    Decimation by 5 
86. licate model set           Note  When you first click the Move teeth button  there appears an IMPORTANT  INFORMATION AND LEGAL DISCLAIMER window  Please read the information  carefully before proceeding         Senf   oe  co  r          4 2 Configuration          GES E     The Configuration tab contains four steps   Setup maxillary model local origo  Setup occlusion plane   Preparation for maxillary model  Preparation for mandibular model     The Configuration step is used to prepare the upper  and or lower model s  for future manipulations and  analysis                 These steps are described in details below        4 2 1 Setup Maxillary Model Local Origo    The aim of this step is to specify the local origin for the maxillary model of the virtual     4 cast  These predefined reference planes namely the horizontal  sagittal and anterior   posterior  can be used as basis for the 2D cross section analysis        3Shape A S 3Shape Inc  3Shape Asia 66  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual     gt  Note  these planes need to be predefined to be available      as default positions for the 2D cross section analysis   section 3 3      Click the Setup maxi
87. lick on the tooth and press Clear to remove the selected  tooth width     Click Clear all to remove all the width measurements        g Ortho  nalyzer   Patient name  John Doe    C  ProgramData sShape OrthoData  A A hboh  o    Application Models View Help     el     B    POR ep AAA                 Manipulation 2        SST        Configuration             Prepare maxillary model    Overview on          a    Ss         F missing Width  2D   0    Set    Step 1 3  Set points     Please set up distal and  D mesial points   Active tooth  9    Show teeth s axes   M  Move close points synchronously    aen                          The user point of view should be the growing direction of the tooth  The default axis of the  tooth crown is defined by the distal mesial segment you define here  Normally it is the  default top view plane for the 2D measurements and for most teeth for 3D measurements   If some teeth grow in a non standard direction  the plane for 3D measurements should be  selected according to those individual directions     Note  Taking a perpendicular view to each crown  using the right button of the  mouse  helps to position the mesial distal segment correctly through the center of  the crown  therefore creating a more realistic tooth axis from the start        Use the Overview window to navigate around the teeth or Ctrl   arrow buttons to change to  next tooth      The small green The next tooth To mark the If the space left from  arrow indicates the which is missing 
88. lisions of the jaws     The Occlusal compass     button allows to color the areas of collision according to the  specific articulator movement using the legend below  2   When the occlusal compass is  disabled  contact colors areas are shown in blue  1      PT  Protrusion    iT  Laterotrusion       The legend of the compass    Record contacts   if checked  enables the Adapt design section  Indicate the Min distance  and Adaption radius by setting the parameters in the appropriate edit boxes     br Step 4  Simulate articulation    3Shape A S 3Shape Inc  3Shape Asia 30  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual    3shape gt     It is possible to imitate the articulation motions by clicking the button to start the  articulation  Click to pause the process or to stop it  To repeat the process click    Click the button to customize the motion sequence        Sequence view    Laterotrusion round trip  Pro  retrusion round trip  Linear motion A to B     End     Motion view    Occlusion  no effect if auto shut is active     Laterotrusion  min   Laterotrusion  max     Pro  retrusion    1  List of sequences    Edit buttons    Bait motion sequence ee       Operation buttons    
89. llary model local origo    button in the Configuration tab   Pick a point on the maxillary model to set up local origo and coordinate system   Rotate the model using the mouse     WN e    e Drag the control points  they turn yellow when activated  to rotate coordinate axis  freely and set up the appropriate relation of the local origin planes    e Drag the arrowhead to move the horizontal plane up or down    e Drag the arrowhead to move the saggital plane left or right    e Drag the arrowhead to move the vertical plane to or from     4  When needed  you can click the Clear button to reset the positioning of the planes  and start the process again  Click OK to save the changes made to the local origin and leave  the step         Note  All planes can be moved and saved as additional planes in the 2D cross section          toolbox   3Shape A S 3Shape Inc  3Shape Asia 67  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual          Application Models View Help      lel                a HEET 4400044    Manipulation 2 Don    All Active    Ki    Anterior Posterior active em ES       Horizontal active    Configuration Sagittal active                Analysis    Model Set Comp
90. mation        Note  It is advisable to use the Dual view  visualization in order to access both models  at the same time  The selection of points can  be done on the reference model first and  then on the comparative model  or vice  versa  Use the Reset button to delete the  reference points if needed        3Shape A S 3Shape Inc  3Shape Asia 98  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual       NS  SS C  Model Set Comparison  Al E  E  A    Model Visibility    Reference Both       Step 2  Gain better alignment with the Selection tools   The additional surface information provided with the Selection tools improves the  alignment process  When no surface correspondences are set  the system automatically  uses the whole surfaces of the models as the reference surfaces     These tools are only available in Surface 1 point and the Surface 3 point registration  methods as the Direct 3 point method does not refer to surfaces     The selection tools can be used in any order    Selection Tools  and combination     The tools include the following        Item Action  Al Unselect all   Unselects all selections   wx Reduce selection   Reduces the selected area by e
91. n allows you to customize the   gtt aam a   default placement method and perform auto placement of the   model  Click it to open the Auto placement options window     Cond  incl  R 34 00 z       3Shape A S 3Shape Inc  3Shape Asia 26  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p    gt   Ortho System    2012 User Manual    Auto placement options    Auto placement method        Analyze scans  for use without adapter plates     Use guide plane        Articulator specific  for use with adapter plates     C Use custom placement    Set as default       You will need to click the Browse button and select your placement file to use   The Set as default button saves you current auto placement method to use as the default  one for future orders     The Perform placement button initiates the auto placements process with the chosen  options    Analyze scans is selected for the models without adaptor plates    You can load predefined planes created in OrthoAnalyzer  such as the occlusion plane as  default position in the articulator by checking the User Guide plane box and selecting the  plane from the drop down list    Mark the Use guide plane to activate the drop down menu of the planes  used for the  
92. n the right with the button   Use the button to remove the selected    steps from the Current workflow steps list if  needed     Change ID    Change ID    Please select a valid unigue ID     ID Preparation   OK    Cancel   The customized workflow wizard name can be  edited by selecting it from the Workflow list  and clicking the Change ID button        You can specify color of the selected wizard by  clicking the Workflow color cube and selecting  the desired color from the available palette     e Other operations    With the other operations you can Copy  Delete  Move up and Move down the selected  wizards  The deleted wizards are kept in the Recycle bin  You can either restore them or  empty the Recycle bin     The Export and Import buttons allow you to easily export or import your wizard settings  to from a   3ml file     Click the Save button at the top of the window to save your changes in the Ortho Control  Panel     Only the sequence of steps defined for the wizard in the Ortho Control Panel appears in the  OrthoAnalyzer interface on the wizard icon selection  The following image shows the  operational steps of the default Preparation wizard in the Ortho Control Panel and  OrthoAnalyzer interface     3Shape A S 3Shape Inc  3Shape Asia 115  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 13
93. ne   86 138 183 38960 Web  www 3shape com       Copyright 2006 2011 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2010 User Manual    Open models    General Preview maxilla    C Documents and Settings V4ll Users   4pplication Dataya5 hape     Show preview  Drowse     _  Decimate db models to  triangles Fotate    Maxillary model    Mavller model filename     C Documents and SettingstAll Users4pplication Datay35hape st  Preview mandible    Number of tangles  92108  Number of vertices  46056    Mandibular model    Mandibular model filename     C  ADocuments and Settings V4ll Users 4pplication Data 35 hapest    Browse  Number of tangles  97806    Number of vertices  48905                 e Virtual Base  3Shape A S 3Shape Inc  3Shape Asia 107  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual      irtual Base  Teeth models A    Select base model       Di  Full  upper   base 1       Choose points for cutting spline on the    teeth     Clear splines    Clear splines      3Shape A S   Holmens Kanal 7  DK 1060 Copenhagen K  Phone  45 70 27 26 20    3Shape Inc   571 Central Ave   Suite 109       Phone   1 908 219 46 41       New Providence  New Jersey 07974    3sh
94. nes can be moved and saved as additional planes in the 2D cross   section toolbox           Click Clear to reset the plane or click OK to save and finish the step     3Shape A S 3Shape Inc  3Shape Asia 69  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p      gt   Ortho System    2012 User Manual _ _ S       4 2 3 Preparation for Maxillary Model    P  This step has 4 main objectives     1  It lets you define the composition of the maxillary tooth row  including missing teeth to  calculate the required space  You can also set up the width measurements for missing or  non erupted teeth    2  It also segments the teeth according to their definition so you can perform a virtual  setup    3  It defines the axis of the crown  which will be used as basis for all tooth movements at  the virtual setup stage   4  It allows to edit position of the rotation center of the tooth    Completing this step is crucial for the further analysis and for virtual setup operations to be  successfully performed in the Function panel     The P Preparation for maxillary model option contains three steps     e 1 3  Set points  e 2 3  Define cut  e 3 3  Finish       These steps are described in details below     4 2 3 1 Set
95. ning of  the maxillary and the mandibular models  In the new window which pops up immediately  after you push the Rotate button  move the Rotation degrees sliding bar  minimal value  being  180    maximal 180    to bring the rotation angle to the necessary value  View the  changes made in the preview boxes provided  to help you to control the maxillary   mandibular and the occluded modes rotation     3Shape A S 3Shape Inc  3Shape Asia 17  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual    Rotation degrees   180 OS ER       Step 6  Click Load to display the selected model s  in the session window and start the    analysis session     2 OrthoAnalyzer User Interface    The user interface comprises of the following four sections as indicated on the image below     1  Main toolbar   2  Visualization toolbar  3  Functional panel   4  Session window    3Shape A S 3Shape Inc    Holmens Kanal 7 571 Central Ave   Suite 109  DK 1060 Copenhagen K New Providence  New Jersey 07974  Phone  45 70 27 26 20 Phone   1 908 219 46 41    3Shape Asia 18  Room 1205  No 738 Shangcheng Road  200120 Shanghai Mail  info 3shape com    Phone   86 138 183 38960 Web  www 3shape com       Copyright    200
96. ocal Ortgo     e esse eeeeeeeeeeeeeeeeeeeennees 66   A 2 2 Deep OCCISO E Te EE 68  4 2 3 Preparation for Maxillary Model    70  4 2 4 Preparation for Mandibular Model      cccccccccccc cece cece eee e eens eee eeeeeeeeeeeeeeeeeeeeeeeenenes 81  BD PAINGIY EE 82  425 1  Dental  Aro ANANY EE 82  AS 2 Pillay SiS RODO asta ning ig est eete nine yess ete ote cree beers  te ate ese A T E 85   A 5s OV El DIC OV JE Eorna ituna vancounciuducsee even euackeduesneeveceuastevendactesaeanananananananancnanen 88  4 3 4 OQUCSTIONNAlPCS EE 91  EE ale ROPOT eege 94  AO OCCHUSI OM Mie e EE 96  4 4 Model Set COM Dd ee 96  4 4 1 Compare Model Gerten 97  4 1 2 Maxillary Model Registration NEE 98  4 1 3 Mandibular Model Registration      cccccccccccce eee eee eee eee e eee e eee eeeeeeeeeeeeeeeeeeeeneees 101  4 1 4 Difference Map for TWO Model Sets    cccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 101   ome   ele aNd EXPUN EE 103  J L DAVES Le EE 103  De  Day    MOGCIS E 103   O Croan Lee CHE 105  Sr Cheate Vil al reegen 105  6 2 Open Patient Model Set in Virtual Base             cece cece reer eee ee eee eee e eee e eee eees 112  Z CUSTOMIZE  Workl  Ww Wizard ss ce cere vin cae ceseceeucssineatcesineeussaiaeanecsiaeessisieananesetedaienaees 113    3Shape A S 3Shape Inc  3Shape Asia 2  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone
97. on map     4 3 1 Dental Arc Analysis    The Dental arc analysis function provides a compilation of the tooth width calculations  based on the selections made in the Configuration tab and compares it with the customer   defined ideal curve shape     When you click the A Dental arc analysis button  a dialog box with the Overview  window and the Ideal Curve and Wire Length tab appears     e Overview window    The teeth of the maxillary and mandibular right quadrants are marked red  The teeth of the  maxillary and mandibular left quadrants are marked green  Missing teeth are marked grey     The green arrows along the dental arcs indicate the full arch width calculated out of the  individual tooth widths of the teeth marked in the previous steps  Both types of  measurements appear next to the teeth and the arrow in mm     3Shape A S 3Shape Inc  3Shape Asia 82  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    Dental arch analysis D  S e                 11 127 44    11 57 7 66  SeT     10 37          Ideal Curve and Wire Length O  Ideal Arches    Maxillary arch Show opposite arch         KITO         Bracket offset 1S Copy opposite arch  Ideal arc length  108 02 mm
98. onding bounding  box    2  Drag the purple control points on the ends of the axis arrows  turn yellow  to set  up the ultimate position of the cast     Occlusion a L  ps L      Click the mandibular    maxillary model to adjust  it  Hold the CTRL key to  rotate       r    Modification  Trans box Arrow buttons    Maxillary distance 0 00  amp  mm       Mandibular distance 0 00 mm                                   Colision detect    Plane grid    s         Measurement points      Enter the necessary values for the Maxillary distance and  Mandibular distance to move the upper and the lower casts    up and down        e Arrow buttons     1  Click on either the upper or lower casts to visualize the green arrows   2  Click on one of the four arrows to set up the ultimate position of the cast  Hold the  CTRL key to rotate     3Shape A S 3Shape Inc  3Shape Asia   Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road 49  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com  Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Occlusion  z     Click the mandibular    maxillary model to adjust  it  Hold the CTRL key to  rotate       Modification    Trans box     Arrow buttons    Translation step 0 00   mm        Rotation step g 1 00   deg      V  Collision detect Transition step
99. one   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved    Ortho System    2012 User Manual    Analysis reports    Overview    Tooth width analysis   Bolton analysif   Space Analysis       Standard Moyers Table    Maxillary Space Analysis    Sum of incisor widths    E of left canine  amp  premolars    Sum of right canine  amp  premolars    Total space required    28 88  Tanaka  amp  Johno  Sum of lett canine  amp  premolars    Sum of right canine  amp  premolars    Total space required    Mandibular Space Analysis    Sum of incisor widths    Sum of lett canine  amp  premolars  Sum of right canine  amp  premolars    Total space required       22 46  Tanaka  amp  Johnsa  Sum of lett canine  amp  premolars    Sum of right canine  amp  premolars    Total space required    Space analysis       4 3 3 Overbite  Overjet       Overbite Overjet          Overjet 8  is set  Tune it by  moving landmarks or select  other         L  Enable dipping plane    Invert dipping plane    Objects    AA       EK TU    C 7 Overbite     Overjet   F  Show All    Show Landmarks    3Shape A S   Holmens Kanal 7  DK 1060 Copenhagen K  Phone  45 70 27 26 20    3Shape Inc     571 Central Ave   Suite 109  New Providence  New Jersey 07974  Phone   1 908 219 46 41    The Overbite Overjet function       allows you to  measure the overbite and overjet distances  Please  follow the hints in the form to perform the  measurements     The Objects window in the form contains
100. placement    Articulator specific option is used when the adaptor plates are included    Use custom placement allows you set the path of the placement     Click the Browse button to set the Placement file path     3Shape A S 3Shape Inc  3Shape Asia 27  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual       1  Moves the articulator up and down    2  Rotates the articulator    Change the angle of the articulator  position       J  gt  Step 3  Setup articulator    3Shape A S 3Shape Inc  3Shape Asia 28  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual    Click the LI on the Virtual articulator window to open the  settings tab       irtual articulation                                  Occlusion  0 00 mm   i  e Edit the parameters in the appropriate edit boxes in the  eee  Virtual articulation window    Lateratrusion  0 00   mim e Move the jaws
101. r right molar  URS  and landmar  m a Maxilla ULE in the goave af the irst upper left mokar Rer    Korkhaus B  Line Korkhaus U4_4  Korkhaus C  Line Korkhaus Up 6   Korkhaus D  Korkhaus Distance UL  Korkhaus Schwartz Mandible  Korkhaus B1  Korkhaus Line L4_4   Korkhaus C1  Korkhaus Line L6_6     Summary     Korkhaus C  Line Korkhaus value is undefir  o Korkhaus C Ideal 54 5   Korkhaus C Discrepancy Value is undefined       Unweighted Total   0         It is possible to customize or redefine your measurement by right clicking it            Korkhaus_UR6       Korkhaus_U6_6 Korkhaus_UL6  Aa Di Be    Redefine             Show vd Step analysis objects    All analysis objects          The Additional information section allows you to make notes on the current step     After you have finished working with the step  press the Next button at the bottom of the  window  To come back to the previous question  click at the Prev button     3Shape A S 3Shape Inc  3Shape Asia   Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road 93  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com  Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual    At the end of the scoring process you can view the Summary     Questionaire E    Questionnaire   Korkhaus Schwartz Analyses           Korkhaus Schwartz
102. rements  on the model and make the custom analysis    Articulator   allows to imitate the movements of articulator with the  designed model on the screen    Capture Screenshot   Allows you to capture screen shots with the single  click and save them in the patient s model set    Show material and shadows     Marks the cast segments with the  corresponding material colors and toggles on and off the function of shadow  visualization     Show wireframe   Shows the triangulation of the virtual casts     Show as transparent   Changes the degree of transparency of the virtual  casts     Show perspective   Transforms the model into a realistic 3D object  where    y the distant objects appear smaller than the closer ones    a   D D D     Rotate view     When selected  right click and drag to rotate the view    Pan view     When selected  right click and drag to pan the view    Te   l l   Ce Zoom view     When selected  right click and drag to zoom in and out   3Shape A S 3Shape Inc  3Shape Asia 22  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    Applied views of some of the functions of the Visualization toolbar are shown on the image     f  ee              e e  CH i 
103. s  gets smaller  and then       3Shape A S 3Shape Inc  3Shape Asia 101  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    continues to the colder color  palette  when the surfaces of  the compared model sets start  to intersect     3Shape A S 3Shape Inc  3Shape Asia 102  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com       Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual    5 Saving and Exporting    While working with on a model set  you can always Save you current session by pressing the      Save session function button and save the current feature tree in  3ml format in the  default     OrthoData  folder        5 2 Save Models as       e    i    Ww  With the    Save models as    button you can save your upper lower models to the  specified folders with the chosen names     Save virtual setup as    section saves the simulation you have made for the orthodontic  treatment     Save occlu
104. sion as    section saves the name of the new occlusion     3Shape A S 3Shape Inc  3Shape Asia  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Save models as        Upper model filename     c   programdata 3shape orthodata 2011 1 beta 2001 1 2001_1_   Browse    Save lower model  Lower model filename     c   programdata 3shape orthodata 2011 1 beta 2001 1 2001_1_   Browse          Save occlusion as     Save virtual setup as       Duplicate model set                         3Shape A S 3Shape Inc  3Shape Asia 104  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com          Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual    6 Creating Virtual Base    Creating the virtual base involves a modeling session to align maxillary and mandibular  models  The first step depends on a chosen Create Virtual Base or Open Patient Model  Set in Virtual Base modeling mode  The first option opens any baseless mod
105. t advantageous visualization  The visualization tools are grouped in the Visualization  toolbar and allow to     e Rotate the 3D view to a preset angle  this allows you to view the models from the  front  back  top  bottom etc    e Set the position of objects on the screen for analytical inspection of the models in  relation to each other    e Set the visibility of objects visualizing a part of the virtual cast  which allows for a  more detailed inspection of particular objects on the virtual cast    e Set the objects transparency for the current operation to see or hide their internal  structure    e Switch to custom rotation and panning mode enabling rotation and free movement  of objects on the screen     The buttons in the Visualization toolbar are presented in table below     Note The appearance of the View toolbar depends on whether  the virtual cast is open  see the left images column  or closed   see the right images column      Item Action  View     The view buttons allow you to switch between a number of predefined  viewpoints        e Front view     _ pa e Rear view  ex We e Right side view  ke e Left side view  se a e Top view  a e Bottom view  A  o P  AA    S A    3Shape A S 3Shape Inc  3Shape Asia 21  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com 
106. t the Line Width in the drop down  menu and the Value by indicating the  parameters in the appropriate editbox     S To move the control point  select the  Fae E point  turns MMS  and drag it to its new  position    It is possible to annotate the selected  measurement  turns MME  or Delete it     Delete  Properties       Angle measurement requires three points  With angle measurement  the second point  becomes a vertex of the angle        3Shape A S 3Shape Inc  3Shape Asia 41  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual            1  i          iT   di   3  H  d     d  KE   amp         EH    o   del  5M          3shape gt     It is possible to select the Revert angle  or edit the angle parameters manually     Distance measurement allows to measure a distance to an existing line           3Shape A S   Holmens Kanal 7  DK 1060 Copenhagen K  Phone  45 70 27 26 20    3Shape Inc    571 Central Ave   Suite 109   New Providence  New Jersey 07974  Phone   1 908 219 46 41    d z   F  Spline measurement requires several control points on the curved area     3Shape Asia 42  Room 1205  No 738 Shangcheng Road  200120 Shanghai Mail  info 3shape com    Phone   86 138 183 38960 Web  w
107. tab  To view the ideal arch  select the Show ideal arch checkbox  This  will activate the whole tab and you can select the desired arch and choose to view the  maxillary and mandibular arches by selecting the corresponding checkboxes  Select the  Show as 3D checkbox to view the arch in the 3D format                 Miscellaneous tab  Setup the desired rotation and shift intervals in the corresponding    fields   3Shape A S 3Shape Inc  3Shape Asia 58  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual    To have a better view of the selected tooth  you can mark the Make non selected teeth  transparent checkbox  You can also toggle the Show neighboring teeth only option     When the Perform collision detection checkbox is selected  you can view the collision of  the casts  Choose the threshold of the collision if desired and enter the necessary values     Measurement points tab  Select the Insert points option to trace the slightest changes  of the tooth position  The numerical value over the point will indicate the change of the  position in relation to its previous location     With the Edit flexible tissue region button it is possible to determine the area of the  
108. tooth missing tooth is  tooth selected  Its automatically  shown as intended for specific  number appears selected as    active    transparent   select   purpose  e g  implant  under Active tooth is marked red  The the tooth and check   or non erupted  below  The tooth tooth with Missing  tooth   click the Set  marked with cursor completed selections button and enter the  becomes circled becomes green  corresponding tooth  black  size value in the    Width  2D  field   The virtual tooth  becomes white     3Shape A S 3Shape Inc  3Shape Asia 71  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved  Ortho System    2012 User Manual          Missing Width  2D  11   Set     Missing width  20  0   1 get     Missing width  20  lo           Set      Missing Width  20  0    Additionally  you can manipulate the teeth with the right   click menu appearing in the Overview window when the  cursor is positioned over a tooth     F St    Missing              The default measurements are done in 2D mode as the  software emulates the traditional manual measurement  method  The dental technician can still use the manually  calculated data with the 2D tooth width  The measurement  method can be toggled between 2D and 3D with the Use 
109. tors  comments  model set dates and scan dates associated with all the model sets for  the patient ID selected     24 03 2010 14 33 25  24 03 2010 14 35 16  22 12 2010 11 50 30    LID 2 Patent dty Copenhagen    2000 Patient country Denmark  ame John Doe    ss Holmens Kanal 7       3Shape A S 3Shape Inc  3Shape Asia 8  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual S    C  U Unfolding the patient model set tree further and clicking on one of the model IDs  e g   1002 1   representing the selected model set  will display seven views corresponding to this  particular model        E Open patient case    fb EVER pas    a L  Patient Selection        s Jane Doe A    Mandibular view Maxillary view Right view    Left buccal view Front view Rear view    24 03 2010    24 03 2010  14 38 25       NOTE  There are two preview options available at this stage  small previews and large  previews  Click on the Views button on the top toolbar to select the most convenient  viewing option     3Shape A S 3Shape Inc  3Shape Asia   Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road 3  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai 
110. ual base modelling   iz onthe model set not attached to the patient database       Open patient model set in virtual base   Starts the utility designed for the   ut virtual base modelling inside the patient database     Preparation     Is a customized workflow wizard that contains the following  default steps    Occlusion  Alignment for open model set  Setup local origo on maxillary model   Setup occlusion plane  Preparation for maxillary model  Preparation for  mandibular model    VirtualSetup   Is a customized workflow wizard that contains the following  default steps    Dental arc analysis and Move Teeth    Analyzer   Is a customized workflow wizard that contains the following default  steps    Analysis objects  Overbite Overjet  Dental arc analysis  Analysis reports and  Generate Report     re kk    in order to adapt OrthoAnalyzer to your particular needs  The wizards are    B Note  The customized workflow wizard let you create or edit your own workflows         customized under the Workflow Settings of the Ortho System Control Panel           2 2 Using the Mouse and Keyboard    The use of the mouse and keyboard for common functions in OrthoAnalyzer is identical to  the Windows applications     The use of the right mouse button is mostly restricted to 3D specific operations  The default  setting in OrthoAnalyzer allows you to use the right mouse button to rotate and zoom the  models in 3D view or to pan in 2D view  The configuration can be changed by clicking the  Rotate 
111. uttons a     Click OK to finish the Virtual Setup step     e Applying the interactive tools to a virtual setup    At the virtual setup stage  it is possible to call any of the interactive tools  see the section  3  e g  to apply a predefined customized analysis to assess its results on the set up case   or simply to check critical values  distances etc        Click the Measurements and Custom Analysis button and choose the relevant  analysis  If a customized analysis was already defined  the analysis objects are displayed on  the model at the position on which they were originally set but all distances and measures  are update according to the virtual setup  You can also take any measures with the  available tools     Open the 2D Cross section v tools  and apply the 2D measurements  including the  symmetry guides to the virtual setup     3Shape A S 3Shape Inc  3Shape Asia 63  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com    Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual    You can also apply the virtual articulator Ll and assess the effect of the treatment plan  on the patient   s occlusion dynamically     When the teeth are moved in the virtual setup  all analyses and measures are updated    automatically
112. view  Pan view or Zoom view buttons in the Visualization toolbar or by using the  keyboard shortcuts shown in the table below     Visualization    Corresponding    toolbar Action  key  button  S Press the right mouse button and drag mouse to  Pan view ALT a g  pan the view     Press the right mouse button and drag mouse to  Rotate view CTRL g g  rotate the view   e Press the right mouse button and drag mouse to  Zoom view SHIFT g g  zoom in and out   3Shape A S 3Shape Inc  3Shape Asia 20  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p 2  gt   Ortho System    2012 User Manual    The preferred working practice is to have the Rotate view button of the Visualization  toolbar pressed while using the mouse wheel to perform panning and zooming of the view  as described in the table below  Some functions of the Visualization toolbar are purely  mouse functions     Mouse wheel Action  Pressed Move the mouse in the 3D view to pan   Scrolled Scroll mouse wheel in the 3D view to zoom in and out     2 3 Visualization Toolbar    Finding the right point of view to work on a 3D model most effectively can be difficult and  time consuming  OrthoAnalyzer comes with a set of tools aimed at helping you find the  mos
113. ww 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p e  gt   Ortho System    2012 User Manual       Ht Distance along centre line requires two points  Measures the distance in relation to           FEI the centre line        mm    ri     Symmetry points require one point  Automatically places the second point  symmetrically to the selected one     3Shape A S 3Shape Inc  3Shape Asia 43  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3sha pe  gt   Ortho System    2012 User Manual       vd e  Symmetry guide requires three points     For the Symmetry guide option it  is possible to Show additional line  and display Distance to the center  line           The Plane offset slide bar allows you to move the cross section plane  back and forward from the initial position  with the actual distance values being indicated     The measurements placed on the model in the 2D cross section window are automatically  mirrored on the model in 3D     3Shape A S 3Shape Inc  3Shape Asia 44  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 21
114. xcluding  a the neighboring areas from the selection   3Shape A S 3Shape Inc  3Shape Asia 99  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual       l      Extend selection   Extends the selected area by adding the  Le  neighboring areas to the current selection              _ gt   rh Invert selection   Unselects the selected and selects  Cou unselected areas of the surface    G           Undo last selection   Makes one step back in the selection  operation     Paint selection   Use the brush tool to    paint    the model  reference surface while keeping the left mouse button pressed     u  5        amp   Ca       Result       gt   3Shape A S 3Shape Inc  3Shape Asia 100  Holmens Kanal 7 571 Central Ave   Suite 109 Room 1205  No 738 Shangcheng Road  DK 1060 Copenhagen K New Providence  New Jersey 07974 200120 Shanghai Mail  info 3shape com    Phone  45 70 27 26 20 Phone   1 908 219 46 41 Phone   86 138 183 38960 Web  www 3shape com       Copyright 2006 2012 3Shape A S  All rights reserved 3 S h a p i   gt   Ortho System    2012 User Manual    Model Set Comparison To see the effects produced by the selections of the  ewer ES upper model registration  keep pr
    