1. SIMXVX EXE 11 8 NOTES E 17 Contents MEMO I O DLL Kit 1 Abstract I O DLL means a Dynamic Link Library DLL that operates in conjunction with the simulator engine of the Simulator Debugger The Simulator Debugger when properly set up can load an I O DLL and can operate it synchronously with the timing at which the program executes one instruction read writes to memory or generates an interrupt This allows to debug the target program by simulating the operation of the microcomputer s input output ports or internal peripheral functions This also makes data input output and other linked operations with external tools possible Any desired I O DLL can be created using C C languages Microsoft Visual C a Windows application development environment available on the market is needed to create I O DLLs 2 Configuration The I O DLL accesses the simulator engine simxx exe xx denotes the model name such as 308 or 30 to obtain information on memory or register values etc In turn simxx exe notifies the I O DLL of various information including memory read write information and the number of cycles in which the program executed each instruction The simulator debugger and the I O DLL are configured in the manner shown below Simulator Debugger Notifies the information to I O DLL from simxx exe e The number of
2. Sets memory data at the specified address The write access information performed by this function is not reflected in the GUI output virtual port output and I O script facilities 12 I O DLL Kit Gets register value Function name int RequestGetRegister int regNo unsigned long regValue Parameter int regNo Register number For register numbers see the header file iofuncYiofunc h that is included in the I O DLL sample program Register numbers are defined in this file Example Definition for PD308SIM regNo Register REG Rx F REG RxH F REG RxL F REG Ax F REG FB F REG SB F Bank Rx registers x 0 to 3 High order 8 bits of the BankO Rx register x 0 to 1 Low order 8 bits of the Bank Rx register x 0 to 1 Bank Ax registers x 0 to 1 Bank FB register Bank SB register Rx registers x 0 to 3 High order 8 bits of the Bank Rx register x 0 to 1 Low order 8 bits of the Bank1 Rx register x 0 to 1 Bank Ax register x 0 to 1 REG FB R FB register REG SB R Bank1 SB register REG Rx Rx register indicated by the B flag x 2 0 to 3 REG RxH High order 8 bits of the Rx register indicated by the B flag ee ae ee 1 REG Ax Ax register indicated by the flag x 0 to 1 REG FLG FLG register REG Rx R REG RxH R REG RxL R REG Ax R Description example To get the RO register value in bank 0 RequestGetRegister REG RO F
3. of DLL would you like to create le Edit View Insert Build Help C Regular DLL with MFC statically linked 75866 Regular DLL using shared MFC DLL Extension DLL using shared MFC DLL TODO A What features would you like in your DLL Automation Windows Sockets Would you like to generate source file comments Yes please No thank you Cancel I O DLL Kit Choose Setting from the Project menu of VC and enter the settings described below Select the C C tab and add a definition EXPORTS to the Preprocessor definitions column of the category General Preprocessor definitions WINDLL AFXD LL MBCS USRDLLIODLL EXPORTS Select the Link tab and specify the I O DLL library files sim308 lib and IodllExpLib d lib using absolute or relative paths in the Object library modules column of the category General These library files are stored in the Library directory of CXXMTOOL XIodll If settings are made for Win32 Debug specify IodlIExpLibd lib Object library modules AA ALibrary Sim308 lib 4 4 SLibrarySlodllE xpLibd lib settings are made for Win32 Release specify IodllExpLib lib Object library modules Librar Sim308 lib AA xpLib lib H Choose Setting from the Project menu of VC Set the Output file name column of the category General on the Link tab so that th
4. sSCountFlag FALSE 4 Check on count beginning flag return RequestGetM emory TABSR 1 amp tabsrData if tabsrData amp 0x01 0x01 Check on count beginning flag sCountCycle RequestGetM emory TAO 2 amp ta0Data if sCountCycle gt ta0Data 1 Count down of counter RequestGetM emory TAOI C 1 amp taOicData Requestl nterrupt TAOI NT ta0icData amp 0x7 Generation of timer AO interrupt sCountCyde 0 return void NotifyPreE xecutionP C unsigned long address return void NotifyPostWriteM emory unsigned long address int length if address TABSR if data amp 0x01 0x01 Check on count beginning flag sCountF lag TRUE 10 I O DLL Kit 7 Functions that Get Information from simxx exe This chapter describes specifications of the functions that get information on the simulator engine side from the I O DLL These functions are implemented on the simxx exe side The I O DLL calls these functions to get information from the simulator engine Use these functions to write codes for simulation within the functions implemented in the I O DLL project s source file iofunc iofunc cpp Function name Abstract RequestGetMemory Gets memory data from the specified address RequestPutMemory Sets memory data at the specified address RequestGetRegister Gets a value from the specified re
5. the purpose of any other military use When exporting the products or technology described herein you should follow the applicable export control laws and regulations and procedures required by such laws and regulations All information included in this document such as product data diagrams charts programs algorithms and application circuit examples is current as of the date this document is issued Such information however is subject to change without any prior notice Before purchasing or using any Renesas products listed in this document please confirm the latest product information with a Renesas sales office Also please pay regular and careful attention to additional and different information to be disclosed by Renesas such as that disclosed through our website http www renesas com Renesas has used reasonable care in compiling the information included in this document but Renesas assumes no liability whatsoever for any damages incurred as a result of errors or omissions in the information included in this document When using or otherwise relying on the information in this document you should evaluate the information in light of the total system before deciding about the applicability of such information to the intended application Renesas makes no representations warranties or guaranties regarding the suitability of its products for any particular application and specifically disclaims any liability arising out of the application
6. Renesas products may not be easily detached from your products Renesas shall have no liability for damages arising out of such detachment This document may not be reproduced or duplicated in any form in whole or in part without prior written approval from Renesas Please contact a Renesas sales office if you have any questions regarding the information contained in this document Renesas semiconductor products or if you have any other inquiries Overview The I O DLL kit is provided for the purpose of extending the functions of the Simulator Debuggers Microsoft Visual C a Windows application development environment available on the market is needed to create I O DLLs This user s manual shows the basic information necessary to use the I O DLL kit For details about the language specifications of and the method for using Visual refer to the user s manual included with your product or online help Supported Simulator Debuggers The I O DLL kit cannot be used in all of the Simulator Debuggers For the Simulator Debuggers and their versions which can be run in conjunction with the I O DLL kit refer to the release notes for the I O DLL kit in which they are detailed Rights to use The rights to use the I O DLL kit come under the provisions of the Software License Agreement for the Simulator Debuggers used Please also be aware that the I O DLL kit can only be used in developing your product and cannot be used for any other purpos
7. To our customers Old Company Name in Catalogs and Other Documents On April 1 2010 NEC Electronics Corporation merged with Renesas Technology Corporation and Renesas Electronics Corporation took over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electronics website http www renesas com April 1 2010 Renesas Electronics Corporation Issued by Renesas Electronics Corporation http www renesas com Send any inquiries to http www renesas com inquiry 2 NE S AS 8 10 11 12 Notice All information included in this document is current as of the date this document is issued Such information however is subject to change without any prior notice Before purchasing or using any Renesas Electronics products listed herein please confirm the latest product information with a Renesas Electronics sales office Also please pay regular and careful attention to additional and different information to be disclosed by Renesas Electronics such as that disclosed through our website Renesas Electronics does not assume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of Renesas Electronics products or technical information described in this document No license express implied or otherwise is g
8. amp regValue unsigned long regValue Register value storage area 13 I O DLL Kit Return value int status TRUE Succeeded FALSE Error Functions Gets a value from the specified register Sets a register value Function name int RequestPutRegister int regNo unsigned long regValue Parameter int regNo Register number unsigned long reg Value Register value Return value int status TRUE Succeeded FALSE Error Functions Sets a value in the specified register Generates a interrupt Function name int RequestInterrupt unsigned long vec int ipl Parameter unsigned long vec Vector number int ipl Priority Return value int status TRUE Succeeded FALSE Error Functions Generates a specified interrupt Gets the status of generated interrupts Function name int RequestInterruptStatus unsigned long vec Parameter unsigned long vec Vector number Return value int happen Generation status of interrupt TRUE Generated Vector number are stored in vec FALSE Un generated Vec is indeterminate Functions Gets the status of generated interrupts 14 I O DLL Kit Inspects a total number of execution cycles Function name void RequestTotalCycle unsigned long cycle Parameter unsigned long cycle A total number of execution cycles Return value None Functions Inspects a total number of current execution cycles Inspects a total number of executed instructions Functio
9. and use of the information in this document or Renesas products With the exception of products specified by Renesas as suitable for automobile applications Renesas products are not designed manufactured or tested for applications or otherwise in systems the failure or malfunction of which may cause a direct threat to human life or create a risk of human injury or which require especially high quality and reliability such as safety systems or equipment or systems for transportation and traffic healthcare combustion control aerospace and aeronautics nuclear power or undersea communication transmission If you are considering the use of our products for such purposes please contact a Renesas sales office beforehand Renesas shall have no liability for damages arising out of the uses set forth above Notwithstanding the preceding paragraph you should not use Renesas products for the purposes listed below 1 artificial life support devices or systems 2 surgical implantations 3 healthcare intervention e g excision administration of medication etc 4 any other purposes that pose a direct threat to human life Renesas shall have no liability for damages arising out of the uses set forth in the above and purchasers who elect to use Renesas products in any of the foregoing applications shall indemnify and hold harmless Renesas Technology Corp its affiliated companies and their officers directors and employees against any and all damages
10. arising out of such applications You should use the products described herein within the range specified by Renesas especially with respect to the maximum rating operating supply voltage range movement power voltage range heat radiation characteristics installation and other product characteristics Renesas shall have no liability for malfunctions or damages arising out of the use of Renesas products beyond such specified ranges Although Renesas endeavors to improve the quality and reliability of its products IC products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions Please be sure to implement safety measures to guard against the possibility of physical injury and injury or damage caused by fire in the event of the failure of a Renesas product such as safety design for hardware and software including but not limited to redundancy fire control and malfunction prevention appropriate treatment for aging degradation or any other applicable measures Among others since the evaluation of microcomputer software alone is very difficult please evaluate the safety of the final products or system manufactured by you In case Renesas products listed in this document are detached from the products to which the Renesas products are attached or affixed the risk of accident such as swallowing by infants and small children is very high You should implement safety measures so that
11. ation Press OK to continue Because the I O DLL can be debugged click OK to continue To debug the I O DLL start Simulator Debugger after the simulator engine sim308 exe has started up After sim308 exe started up it is registered displayed in the Windows system tray So you can see that sim308 exe is up and running before you start Simulator Debugger For details the debugging function of VC see the VC user s manual or help I O DLL Kit 6 Functions that Send Information to the I O DLL This chapter describes specifications of the functions that send information on the simulator engine side to the I O DLL These functions are implemented in the I O DLL project s source file iofunc iofunc cpp The simulator engine simxx exe calls these functions as it sends information to the I O DLL Make sure codes for simulation are written in these functions Function name Abstract NotifyStepCycle Notifies the number of execution cycles each time an instruction is executed NotifyPreExecutionPC Notifies the current PC value immediately before executing an instruction NotifyReset Notifies that the target program was reset NotifyStart Notifies that the simulator engine was started NotifyEnd Notifies that the simulator engine was terminated NotifyInterrupt Notifies the vector number vector address for an interrupt when that interrupt was generated NotifyPreReadMemory Notif
12. but Renesas Electronics does not warrant that such information is error free Renesas Electronics assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included herein Renesas Electronics products are classified according to the following three quality grades Standard High Quality and Specific The recommended applications for each Renesas Electronics product depends on the product s quality grade as indicated below You must check the quality grade of each Renesas Electronics product before using it in a particular application You may not use any Renesas Electronics product for any application categorized as Specific without the prior written consent of Renesas Electronics Further you may not use any Renesas Electronics product for any application for which it is not intended without the prior written consent of Renesas Electronics Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas Electronics product is Standard unless otherwise expressly specified in a Renesas Electronics data sheets or data books etc Standard Computers off
13. cycles of the HEW Debugger GUI executed instruction Front End The timing of resetting e R W information of memory etc simxx exe I O DLL Simulator Engine Create Puts gets the information to simxx exe from I O DLL e Puts gets the memory value the register value e The Interrupt generation The verification of the interrupt generation conditions e The stopping of execution of the target program etc I O DLL Kit 3 Method for Creating the I O DLL This chapter describes how to create I O DLLs using Microsoft Visual C 6 0 hereafter abbreviated VC For details on how to use VC see the VC user s manual or help An I O DLL may be created by making use of the I O DLL sample project IodIITemplate which is included with the I O DLL kit or newly from scratch The IodlI Template project is a VC template project provided for creating I O DLLs 3 1 Method for Using the IodlI Template project The following explains how to create I O DLLs from the IodlITemplate project by using an I O DLL for Simulator Debugger for M32C Series as an example To create I O DLLs for other simulator models change the model name 308 described here with any desired model name e g 100 or 30 1 Choose Open Workspace from the File menu of VC Open the project file IodllTemplate dsp for the IodlITemplate project which is stored in a directory under the direc
14. e Technical support Please note that technical support for the I O DLL kit can be obtained by visiting our homepage URL http www renesas com en tools at which latest information is available Active X Microsoft MS DOS Visual Basic Visual C Windows and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and other countries IBM and AT are registered trademarks of International Business Machines Corporation Intel and Pentium are registered trademarks of Intel Corporation Adobe and Acrobat are registered trademarks of Adobe Systems Incorporated All other brand and product names are trademarks registered trademarks or service marks of their respective holders MEMO Contents Contents Me ABSTRA CUT KE 1 2 CONFIGURATION EE 1 3 METHOD FOR CREATING THE UO DLL 2 3 1 METHOD FOR USING THE IODLLTEMPLATE PROIECT eee eene 2 3 2 METHOD FOR CREATING THE NEW I O DEL 3 4 METHOD FOR USING THE I O DLL L 5 5 METHOD FOR DEBUGGING THE DLL 6 6 FUNCTIONS THAT SEND INFORMATION TO THE I O DLL 7 7 FUNCTIONS THAT GET INFORMATION FROM
15. e I O DLL output destination is the directory in which you installed Simulator Debugger Example Output file name C Program Files Renesas HE W Tools Renesas DebugComp Platform PDTarget PD308SI M sample dll Copy iofunc cpp and iofunc h from the iofunc directory of the IodlITemplate project into any directory of the new project you ve created and add them to the project following the procedure described below Choose Add To Project Files from the Project menu of VC select iofunc cpp from the ensuing list and click OK Open infunc h and change the main header file specification for the application included in it to the new main header filename you ve created Example include XIodlITemplate h gt include sample h Open iofunc cpp then write the code for simulation When you build an I O DLL sample dll is created I O DLL Kit 4 Method for Using the HO DLL This chapter describes how to use an I O DLL in the Simulator Debugger after loading it Before you can use an I O DLL you must first register it to simxx exe If simxx exe has an I O DLL registered in it when you start it loads the registered I O DLL before starting simulation The following explains how to use an I O DLL after registering it to the Simulator Debugger by using Simulator Debugger for M32C Series as an example To use I O DLLs for other simulator models change the model name 308 described h
16. ere with any desired model name e g 100 30 1 the I O DLL file file you want to use into the directory in which you installed Simulator Debugger Note that the Simulator Debugger is stored in the directory shown below HEW install directory Tools Renesas DebugComp Platform PD Target PD308SIM 2 Register the I O DLL to simxx exe To do this write the I O DLL filename in sim308 exe s environment setup file sim308 ini The sim308 ini file exists in the directory in which you installed Simulator Debugger However this file is nonexistent if you have never started Simulator Debugger since you installed it In that case this file needs to be newly created using an editor 3 In the sim308 ini file create DLLNAME section and write an I O DLL filename after IODLL with the extension dll removed as shown below Example When an I O DLL file name is Sample dll DLLNAME IODLL Sample 4 When you start Simulator Debugger the I O DLL is loaded If you do not use the I O DLL delete the description of the DLLNAME section that you created in the sim308 ini file before starting Simulator Debugger DLLNAME lt Delete IODLL Sample lt Delete I O DLL Kit 5 Method for Debugging the I O DLL This chapter describes how to debug the I O DLL you ve created To debug the I O DLL in VC you need to change settings of the I O DLL project The following shows the contents of chang
17. es you need to make by using the case of debugging an I O DLL for Simulator Debugger for M32C Series as an example To debug I O DLLs for other simulator models change the model name 308 described here with any desired model name e g 100 or 30 1 2 Following the procedure described in the preceding section register the I O DLL to make it usable H Choose Setting from the Project menu of VC Set the Output file name column of the category General on the Link tab so that the I O DLL output destination is the directory in which you installed Simulator Debugger Example Output file name C Program Files Renesas H E W Tools Renesas DebugCompY PlatformY PDTarget PD308SI M sample dll Choose Setting from the Project menu of VC Set up the Executable for debug session column on the Debug tab so that the simulator engine executable file sim308 exe stored in the directory in which you installed Simulator Debugger becomes the debug time executable file Executable for debug session C AMTOOLAPD 308S1M sim308 exe gt Example Executable for debug session C Program Files Renesas H EW Tools Renesas DebugComp PlatformY PDTarget PD308SI M X sim308 exe After you finished setting up choose Start Debug Go from the Build menu of VC to start debugging The message shown below will appear sim308 exe does not contain debugging inform
18. gister RequestPutRegister Sets a value in the specified register RequestInterrupt Generates a specified interrupt RequestInterruptStatus Gets the status of generated interrupts RequestTotalCycle Inspects a total number of current execution cycles RequestInstructionNum Inspects a total number of currently executed instructions RequestStop Causes the target program to stop running RequestErrorNum Gets an error number when an error occurred in the immediately preceding function that was executed Below shows a specification of the function Gets memory data Function name int RequestGetMemory unsigend long address int length unsigend long data Parameter unsigned long address Memory address int length Data length of memory data 1 1 byte 2 2 byte 3 3 byte 4 4 byte unsigned long data Memory data storage area Return value int status TRUE Succeeded FALSE Error Functions Gets memory data from the specified address The read access information performed by this function is not reflected in the virtual port input and I O script facilities 11 I O DLL Kit Sets memory data Function name int RequestPutMemory unsigend long address int length unsigend long data Parameter unsigned long address Memory address int length Data length of memory data 1 1 byte 2 2 byte 3 3 byte 4 4 byte unsigned long data Memory data Return value int status TRUE Succeeded FALSE Error Functions
19. ice equipment communications equipment test and measurement equipment audio and visual equipment home electronic appliances machine tools personal electronic equipment and industrial robots High Quality Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems anti crime systems safety equipment and medical equipment not specifically designed for life support Specific Aircraft aerospace equipment submersible repeaters nuclear reactor control systems medical equipment or systems for life support e g artificial life support devices or systems surgical implantations or healthcare intervention e g excision etc and any other applications or purposes that pose a direct threat to human life You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics especially with respect to the maximum rating operating supply voltage range movement power voltage range heat radiation characteristics installation and other product characteristics Renesas Electronics shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products beyond such specified ranges Although Renesas Electronics endeavors to improve the quality and reliability of its products semiconductor products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions unde
20. ies the read address and data length immediately before reading from memory when a memory read from the target program occurred NotifyPostWriteMemory Notifies the write address data length and data value after data was written from the target program to memory Below shows a specification of the function Notifies the number of execution cycles an instruction is executed Function name void NotifyStepCycle int cycle Parameter int cycle The number of the executed cycles Return value None Functions Notifies the number of execution cycles each time an instruction is executed Notifies the current PC value before executing an instruction Function name void NotifyPreExecutionPC unsigned long address Parameter unsigned long address PC value before executing Return value None Functions Notifies the current PC value immediately before executing an instruction Notifies the reset Function name void NotifyReset void Parameter None Return value None Functions Notifies that the target program was reset I O DLL Kit Notifies the start of simulator engine Function name void NotifyStart void Parameter None Return value None Functions Notifies that the simulator engine was started Notifies the terminate of simulator engine Function name void NotifyEnd void Parameter None Return value None Functions Notifies that the simulator engine was terminated N
21. n name void RequestInstructionNum unsigned long inst Parameter unsigned long inst A total number of currently executed instructions Return value None Functions Inspects a total number of currently executed instructions Causes the target program to stop running Function name void RequestStop void Parameter None Return value None Functions Causes the target program to stop running 15 I O DLL Kit Gets error information Function name int RequestErrorNum void Parameter None Return value int errNum Error number Functions Contents Specified level of priority out of range 202 Can t get enough memory Gets an error number when an error occurred in the immediately preceding function that was executed This function allows to get information on what error occurred when one of the following functions was called and its returned value was false e RequestGetMemory function e RequestPutMemory function e RequestGetRegister function RequestPutRegister function RequestInterrupt function Use example unsigned long data char str 5 if RequestGetM emory 0x800 4 data FALSE 1 sprintf str od RequestE rrorN um MessageBox NULL str Error number MB OK Display error number to message box 16 I O DLL Kit The following shows an example of how to write the above functions The shaded sections in this example are the template pa
22. otifies the generate of interrupt Function name void NotifyInterrupt unsigned long vec Parameter unsigned long vec Vector number Return value None Functions Notifies the vector number for an interrupt when that interrupt was generated Notifies immediately before reading from memory Function name void NotifyPreReadMemory unsigned long address int length Parameter unsigned long address Memory address int length Data length of memory data 1 1 byte 2 2 byte 3 3 byte 4 4 byte Return value None Functions Notifies the read address and data length immediately before reading from memory when a memory read from the target program occurred I O DLL Kit Notifies after data was written from memory Function name void NotifyPostWriteMemory unsigned long address int length unsigned long data Parameter Return value Functions unsigned long address Memory address int length Data length of memory data 1 1 byte 2 2 byte 3 3 byte 4 4 byte unsigned long data Memory data value None Notifies the write address data length and data value after data was written from the target program to memory I O DLL Kit The following shows an example of how to write the above functions The shaded sections in this example are the template part of the above functions that are implemented in the iofunc cpp file void NotifyStepCyd e int cycle unsigned longtabsr Data ta0Data ta0icData if
23. ple dll I O DLL Kit Open infunc iofunc cpp then write the code for simulation The infunc iofunc cpp has implemented in it the functions called from sim308 exe Use a function that accesses sim308 exe in the desired function as you write the code for simulation When you build an I O DLL sample dll is created 3 2 Method for Creating the new I O DLL To create a new I O DLL without using the IodlI Template project follow the procedure described below 1 Choose New from the File menu of VC Then create a new project with settings shown below Select MFC AppWizard dll on the Projects tab Set any project name and location Example sample project Choose Create new workspace Check Win32 in the Platforms Click the OK gt Close Files Projects Workspaces Other Documents ee ATL COM Appwizard Project name Cluster Resource Type Wizard ame Custom Appwizard y Database Project Location DevStudio Add in Wizard D SA ISAPI Extension Wizard Activex ControMizard Create new workspace AppWwizard dll C Add to current workspace 24 MFC App Wizard Dependency of T Utility Project p j 3 win32 Application Win32 Console Application Win32 Dynamic Link Library F win32 Static Library Eve In MFC AppWizard Step 1 of 1 Microsoft Developer Studio Jl what type
24. r certain use conditions Further Renesas Electronics products are not subject to radiation resistance design Please be sure to implement safety measures to guard them against the possibility of physical injury and injury or damage caused by fire in the event of the failure of a Renesas Electronics product such as safety design for hardware and software including but not limited to redundancy fire control and malfunction prevention appropriate treatment for aging degradation or any other appropriate measures Because the evaluation of microcomputer software alone is very difficult please evaluate the safety of the final products or system manufactured by you Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances including without limitation the EU RoHS Directive Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations This document may not be reproduced or duplicated in any form in whole or in part without prior written consent of Renesas Electronics Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas Elec
25. ranted hereby under any patents copyrights or other intellectual property rights of Renesas Electronics or others You should not alter modify copy or otherwise misappropriate any Renesas Electronics product whether in whole or in part Descriptions of circuits software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples You are fully responsible for the incorporation of these circuits software and information in the design of your equipment Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits software or information When exporting the products or technology described in this document you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations You should not use Renesas Electronics products or the technology described in this document for any purpose relating to military applications or use by the military including but not limited to the development of weapons of mass destruction Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture use or sale is prohibited under any applicable domestic or foreign laws or regulations Renesas Electronics has used reasonable care in preparing the information included in this document
26. rt of the above functions that are implemented in the iofunc cpp file void NotifyPostWriteM emory unsigned long address int length unsigned long data 1 if address 0 RequestGetRegister REG PC amp val Get PC Value RequestP utM emory 0x800 4 val Store PC value in 0x800 address else if address 0x3e1 4 RequestPutRegister REG RO F data Store value in bankO RO register Requestl nterrupt 21 7 Generation of timer AO interrupt return 8 Notes Changes of values input output to or from memory using the I O DLL cannot be referenced using the GUI output virtual port input output or I O script facilities of Simulator Debugger 2 Only one I O DLL can be specified in Simulator Debugger You cannot specify multiple I O DLLs 17 I O DLL Kit MEMO 18 I O DLL Kit User s Manual Publication Date Nov 01 2006 Rev 1 00 I Sales Strategic Planning Div Pubigned Bys Renesas Technology Corp Microcomputer Tool Development Department Edited by Renesas Solutions Corp 2006 Renesas Technology Corp and Renesas Solutions Corp All rights reserved Printed in Japan DLL Kit User s Manual 241 NE SAS Renesas Electronics Corporation 1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan REJ10J1510 0100
27. tory in which the I O DLL package is installed hereafter referred to as C XRenesasYIodll SamplesYPDxxSIMYIodlITemplate Choose Setting from the Project menu of VC Check path settings for the I O DLL library files sim308 lib and IodIIExpLib d lib which are specified in the Object library modules column of the category General on the Link tab The file locations must be specified using absolute or relative paths These library files are stored in the Library directory of C YRenesasYIodll e Ifsettings are made for Win32 Debug specify IodlIExpLibd lib DObject library modules AA NLibran Sim308 lib sLibraryModllE pLibd lib e I fsettings are made for Win32 Release specify IodIIExpLib lib Object library modules AA ALibrarySim308 lib 4 4 LibrarySlodllE xpLib lib Choose Setting from the Project menu of VC Change the IO DLL filename IodllTemplate dll which is specified in the Output file name column of the category General the Link tab to another filename you want extension dlI so that the I O DLL output destination is the directory in which you installed Simulator Debugger Notethat the Simulator Debugger is stored in the directory shown below HEW install directory Tools Renesas DebugComp Platform PD Target PD308SIM Example Output file name C Program Files Renesas HE W Tools Renesas DebugCompY Platform PDTarget PD308SI M sam
28. tronics products or if you have any other inquiries Note 1 Renesas Electronics as used in this document means Renesas Electronics Corporation and also includes its majority owned subsidiaries Note 2 Renesas Electronics product s means any product developed or manufactured by or for Renesas Electronics 44 NC SAS C 7 D d lt D D UO DLL Kit User s Manual Simulator Debugger Customizing Kit Renesas Electronics www renesas com Rev 1 00 2006 1 1 10 11 12 13 Notes regarding these materials This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use Renesas neither makes warranties or representations with respect to the accuracy or completeness of the information contained in this document nor grants any license to any intellectual property rights or any other rights of Renesas or any third party with respect to the information in this document Renesas shall have no liability for damages or infringement of any intellectual property or other rights arising out of the use of any information in this document including but not limited to product data diagrams charts programs algorithms and application circuit examples You should not use the products or the technology described in this document for the purpose of military applications such as the development of weapons of mass destruction or for