Home

PCR-LE Series - Kikusui Electronics Corp.

image

Contents

1. OVA PERFORMANCE Wide ranging specs DC output also supported 1 to 300V 1 to 999 9HZ 1 4 tO 424V In addition the system supports a DC output mode and AC DC output mode The system can be useful in a wider range of fields such as chemistry and ohysics related areas Output voltage rating AC Output frequency rating Output voltage rating DC Selectable response mode Allows select of a response mode for the internal amplifier system depending on the load condition and application High speed response FAST Normal response MEDIUM Highly stable resoonse SLOW Excluding PCR6000LE and PCR9000LE for requesting a rate of power rise fall for testing various power supply environments for power supply for EMC testing sites Power line abnormality simulation In AC mode it is possible to simulate power line abnormalities by setting the output of the PCR LE series system to the state of a power outage voltage drop dip or voltage increase pop This allows the ability to test Switching power supplies and electronic equipment power outage voltage increase pop voltage drop dip Various measuring functions Output voltage current RMS values peak voltage current effective power apparent power and power factor can be measured It is possible to analyze harmonics up to 40th order of the output current Sequence function The outp
2. New Energy Field With various options the low frequency immunity test and various power enviroment tests are supported The options for parallel operation and three phase operation enable you to expand a single phase system up to 27KkVA single phase three wires up to 54kVA and a three phase system up to 81kVA The system can be applied to a large scale EMC Site for testing of industrial high capacity air conditioners Applications gt Research amp Development Proof evaluation for power supply abnormality EMC testing gt Adjustment amp Inspection Lines Power supply voltage margin check Automated inspection system gt Production Lines For stabilizing the line power supply Automated testing system Quality Assurance IEC Standard Testing gt After Sales Service As power supply for repair and calibration To reproduce power line abnormalities AC PowER SUPPLY PCR LE SERIES Lineup PCR4000LE Model Output capacity Single phase 500VA Single phase 1kVA Single phase 2kVA Single phase 3kVA Single phase 4kVA Single phase 6kVA Single phase 9kVA Maximum output current 5A 2 5A 10A 5A 20A 10A 30A 15A 40A 20A 60A 30A 90A 45A 100V 200V Apparent input power Approx 0 93KVA ORS AVN Approx 1 8KVA 1 8kVA Approx S 6KVA 3 6kKVA Approx 5 5kVA 5 5kKVA Approx 7 3kVA 7 3KVA Approx 10 6KVA 10 Approx 10 6KVA Approx 15 7kVA Input current 100V 200V 11 3A 5 5A 22A 10 8A A
3. 2 When the input voltage is 100 V or 200 V the output voltage is 100 V or 200 V the output current is the rated value the load power factor is 1 and the output frequency is between 40 Hz and 999 9 Hz 3 When the output frequency is between 45 Hz and 65 Hz with no load and at room temperature 4 When the maximum voltage is between 1 V and 100 V L range or 2 V and 200 V H range and the load power factor is between 0 8 and 1 When the output voltage is between 100 V and 150 V L range or 200 V and 300 V H range the output current is reduced by the output voltage When the load power factor is between 0 and 0 8 the output current is reduced by the load power factor When the output frequency is between 1 Hz and 40 Hz the output current is reduced by the output frequency 5 For capacitor input rectifier loads however this is limited by the rated output current s rms value 6 When the output voltage is 100 V or 200 V and the output frequency is between 40 Hz and 999 9 Hz reverse current is 180 deg out of phase with the output voltage 7 With no load at room temperature 8 When the output voltage is between 100 V and 212 V L range or 200 V and 424 V H range the output current is reduced by the output voltage 9 Limited by the rated output current s rms value 10 With respect to changes in the rated range 11 With respect to O to 100 changes in the rating When the output voltage is between 80 V and 150 V L range or 160 V a
4. the rated output current is the product of output current ratios shown in both graphs The output current ratio shown in the Output freque versus rated output current characteristics graph is given priority if it is less than the product of output current ratios described above This only applies to AC mode Model Remarks GPIB interface IBO5 PCR LE USB interface US0O5 PCR LE LAN interface LNO5 PCR LE Analog interface EX05 PCR LE Available in the near future for PCR1000LE AC5 5 3P3M M4C 3 core cabtire cables 5 5 mm 3 m M4 for PCR2000LE AC8 1P3M M5C 3S 3 single core cables 8 mm 3m M5 Input power cable for PCR3000 6000LE AC14 1P3M M8C 3S 3 single core cables 14 mm 3 m M8 for PCR4000LE AC22 1P3M M8C 3S 3 single core cables 22 mm 3 m M8 for PCR9000LE AC14 1P3M M5C 4S 4 single core cables 14 mm 3m M5 Extension cable for control panel ECO5 PCR 2m Parallel operation driver Master Parallel operation driver Slave PDO5SM PCR LE PDO5S PCR LE Available in the near future Available in the near future Single phase three wire driver 2P05 PCR LE Available in the near future Three phase output driver 3P05 PCR LE Available in the near future KRB4 For inch type rack EIA for PCR500LE KRB200 For metric type rack JIS KRB6 For inch type rack EIA Rack mount for PCR1000LE yp EIA Brakets KRB300 For metric type rack JIS KRB9 For inch type rack EIA for PCR2000LE l KRB400 PCR
5. 1 11 3A 5 5A 22A 10 8A 44 A 21 5A 66 A 32 A 88 A 43 A 64 A 55 A AC mode output ratings AC rms Voltage output L range output H range 1 V to 150 V 2 V to 300 V Resolution 0 1V Voltage setting accuracy output L range output H range 1 0 3 of set 0 6V Max current output L range output H range 2 5A 2 5A 1OA 5A 20A 10A 30A 15A 40 A 20A 60 A 30 A 90 A 45A Phase Single phase Power capacity IWA Maximum peak current 3 Max current rms x 4 Max reverse current 4 30 of the max current rms Load power factor O to 1 leading or lagging 2 Frequency 2 1 Hz to 999 9 Hz Resolution 0 01 Hz 1 00 Hz to 100 0 Hz 0 1 Hz 100 0 Hz to 999 9 Hz DC mode output ratings Voltage output L range output H range 1 4 V to 212 V 2 8 V to 424 V 0 1 V Voltage setting accuracy output L range output H range 7 0 05 of set 0 05 V 0 05 of set 0 1 V Max current 8 35A 175A 7A 35A 14A 7A 21A 10 5A 28A 14A 42A 21A 63 A 31 5 A Max instantaneous current 9 Max current rms x 3 6 Output voltage stability Line regulation 10 Within 0 1 Load regulation output L range output H range 11 Within 0 1 V within 0 2 V _ FAST Within 0 2 Output frequency variation 12 MEDIUM Within 0 3 Ripple noise in DC mode 5 Hz to 1 MHz components 0 15 Vrms or less 0 15 Vrms or less 0 15 Vrms or less 0 2 Vrms or less 0 2 Vrms or less 0 25 Vrms or less 0 25 Vrms or less Am
6. AA 21 5A 66A 32A 88A 43A all Dimensions 4306 99 16 93 430 16 99 W 16 93 as016 93 w 16 93 W s30 t6 93 4aor7 32 16 93 440 17 32 s30 t6 93 4aor7 32 430LBS AMOLI 16 93 440 17 32 430LBS AMOLI 430 16 93 440 17 32 LULU a 81 195 7 68 H 262 10 31 345 13 58 H 389 15 31 475 18 70 H 690 27 17 785 30 91 H 690 27 17 785 30 91 H 944 36 17 1040 om Maximum JE dimensions 5452146 600 28627 0 21 46 600 23 62 D 545 21 46 595 23 43 D 545 21 46 595 23 43 D 545 21 46 595 23 43 D 545 21 46 595 23 43 D 545 21 46 595 23 43 D Weidht Approx 17kg Approx 35kg Approx 55kg Approx 82kg Approx 96kg Approx 140kg g 37 48lb 77 16lb 121 25lb 180 78lb 211 64lb 308 64lb Appearance
7. EC6 1000 4 27 Unbalance in units O Variation in power supply frequency for units with 16 A phase IEC61000 4 29 Voltage drop dip instantaneous power failure O EE and voltage variation in DC IEC6 1000 4 34 A A Voltage drop dip instantaneous power failure and voltage A A variation for units with input current exceeding 16 A phase O O Immunity testing for units with 16 A phase except for those required by IEC61000 4 34 m a 22 eee Distributor Representative W All products contained in this catalogue are equipment and devices that are premised on use under the supervision of qualified personnel and are not designed or produced for home use or use by general consumers W Specifications design and so forth are subject to change without prior notice to improve the quality Hi Product names and prices are subject to change and production may be discontinued when necessary Ml Product names company names and brand names contained in this catalogue represent the respective registered trade name or trade mark Ml Colors textures and so forth of photographs shown in this catalogue may differ from actual products due to a limited fidelity in printing Hi Although every effort has been made to provide the information as accurate as possible for this catalogue certain details have unavoidably been omitted due to limitations in space Ml If you find any misprints or errors in this catalogue it would be appreciated if you would infor
8. LE For metric type rack JIS Base holding angle OP03 KRC For fixing PCR3000LE 4000LE 6000LE 9000LE and fixing racks to the floor Immunity tester Available in the near future Line impedance network LIN4OMA PCR L Quick Immunity Sequencer 2 Software for creating sequences SD009 PCR LE Wavy for PCR LE Available in the near future Available in the near future The latest standards for IEC61000 4 supported Power Line Disturbance Immunity Testing Software SDOO9 PCIR LE Quick Immunity Sequencer 2 Available in the near future e SR nen a a i Se a for er a f PATRAT RATTAT ML LELE iai Irj Pirinin k ak Hy eS cee ee ed LE 1 HUTA ATP eT ETTET TETTETETT ETTET i TETTETETT Tee F ali af wwe 11 itl TOCA a ATENTAAT Pe oe g E ee Quick Immunity Sequencer 2 model name SDO09 PCR LE is an application software for immunity testing with the AC power supply PCR LE series system based on the power line disturbance standard IEC61000 4 Series for the immunity testing of the EMC standard Not only can it be used for compliance testing based on the latest standards or for some types of preliminary testing but the software can be also employed for advance checking in development phases and for immunity margin tests because it allows extended testing conditions to be set as needed Q KIKUSUI KIKUSUI ELECTRONICS CORPORATI
9. ON 1 1 3 Higashiyamata Tsuzuki ku Yokohama 224 0023 Japan Phone 81 45 593 7570 Facsimile 81 45 593 7571 www kikusui co jp KIKUSUI AMERICA INC 1 877 876 2807 www kikusuiamerica com KIKUSUI TRADING SHANGHAI Co Ltd www kikusui cn KIKUSUI For our 530 Lakeside Drive Suite 180 Sunnyvale CA 94085 U S A Phone 408 733 3432 Facsimile 408 733 1814 Room D 01 11F Majesty Bld No 138 Pudong Ave Shanghai City Phone 021 5887 9067 Facsimile 021 5887 9069 ocal sales distributors and representatives please refer to sales network of our website Conforming as standard Nearly conforming or modification required List of conformance to the EMC standard tests Gene R not available Conforming alae Single phase Three phase IEC6 1000 4 1 1 Voltage drop dip O O Voltage dipping instantaneous power failure O O and voltage variation Voltage variation O O Flat curve O Over swing O Frequency sweep IEC6 1000 4 13 Odd harmonics the order of which is not a multiple of 3 Higher harmonics wave interharmonic wave Odd harmonics the order of which is a multiple of 3 Even harmonics Interharmonics O Meister curve O IEC6 1000 4 14 Voltage swing Voltage swing Interval IEC6 1000 4 17 Single phase rectifier circuit O Ripple at the DC input power terminal Three phase rectifier circuit I
10. bient temperature variation 13 100 ppm C TYP Output frequency stability output voltage waveform distortion ratio output voltage response speed efficiency Output frequency stability 14 Within 5x10 Setting accuracy 41x10 FAST 0 2 or less Output voltage waveform distortion ratio 15 MEDIUM 0 3 or less FAST 20 us TYP Output voltage response speed 16 MEDIUM 30 us TYP 54 or more IO ie 0 ie Efficiency 17 BE 04 or more 55 or more 57 or more 58 or more Meters fluorescent display Resolution 0 1V Voltmeter 18 Na Accuracy 1 of rdng 2 digits Resolution 0 01 A 0 01 A 0 01 A 0 1 A 0 1 A 0 1 A 0 1 A Ammeter 18 a Accuracy 1 of rdng 2 digits Resolution 0 1 W 1W 1W Wattmeter 19 aE Accuracy 1 of rdng 3 digits Frequency meter Resolution 0 01 Hz 1 00 Hz to 99 99 Hz 0 1 Hz 100 0 Hz to 999 9 Hz BNC terminals SEQ TRIG OUT 20 Pulse width approx 10us open collector output pullup at 5 V and approx 10 KQ serial resistance approx 220 Q maximum sink current 10 mA BNC connector SEQ STAT OUT 20 Step time output open collector output pullup at 5 V and approx 10 kQ serial resistance approx 220 Q maximum sink current 10 mA BNC connector SEQ TRIG IN 20 Operating pulse width 10us or greater photo coupler input driving voltage 5 V serial resistance approx 470 Q active with 7 mA source BNC connector 1 100 V input type or 200 V input type
11. g Comparison with the existing PCR LA 4 kVA Existing model PCR4000LE PCR4000LA mn FEP St tf Downsized by approx 20 Mass Da 5 e Decreased by T E M approx 20 Specifications for large capacity It is possible to expand to 27 kVA single phase 54 kVA single phase 3 wire and 81 kVA three phase by using the parallel single phase 3 wire and three phase operation options expansion operation drivers This allows the system to be used for large scale EMC site power or as test power for large capacity industrial air conditioners W Parallel operation The separately sold expansion operation driver is required 2 kVA or higher model Max connectable units 5 Max expansion capacity Single phase 27 kVA Can be expanded to 54 kVA single phase 3 wire or 81 kVA three phase when used in combination with the single phase 3 wire option or three phase option Combinations of different models are possible Example PCR2000LE PCR4000LE PCR6000LE Single phase 12 kVA A N W Single phase 3 wire three phase operation The separately sold expansion operation driver is required All models Max expanded capacity 54 kVA single phase 3 wire 81 kVA three phase When used in combination with the parallel operation option x Combinations of different models are possible Example PCR2000LE PCR2000LE PCR4000LE Three phase unbalance 8 kVA aoe Excellent mainte
12. gee http www kikusui co jp AC Power Supply NEW High performance multifunctional AC Power Supplies PCR LE Series Capable of various power line abnormality simulations and the sequence operation Single phase 500 VA to 9 KVA Supporting the system for the single phase and expandable with optional drivers for the single phase three wire and three phase operation Expandable capacity up to 27 kVA single phase 54 kVA single phase three line and 81 kVA three phase Features a full range of measuring functions and supports AC DC and AC DC Outputs Detachable front panel Eco friendly function equipped RS 232C as a standard interface and GPIB USB and LAN LXD are available as an optional interface KIKUSUI New stage of AC power supply supporting new energy field lt Smart Grid Vision gt High performance AC Power Supplies PCR LE SERIES The PCR LE Series is a new line of advanced multifunctional AC power supply that has been developed from our PCR L LA Series linear amplifier type The PCR LE Series provides high reliability and can be applied to various applications by taking advantage of the features that can control broadband waveform freely Moreover the PCR LE Series can be configured as a core device of a test system combined with E loads and Power Analyzers for Grid Connection Testing in regard to dispersed power generation such as Solar Power Wind Power Fuel Cell and Gas Engine referred to as
13. ility EMC 1 2 Safety 1 Does not apply to specially ordered or modified PCR LEs 2 Only on models that have the CE marking on the panel W Output voltage ratio versus rated output current characteristics The output voltage ratio is a percentage where 100 represents an output voltage of 100 V output L range or 200 V output H range in AC mode or DC mode The output current ratio is a percentage where 100 represents the maximum rated output current in AC mode or DC mode E Output voltage ratio versus rated output current characteristics AC mode Output voltage ratio versus rated output current characteristics DC mode AC mode DC mode eT NE 7 ao a eee eee Se gt so ttt ttt ttt tt TTN ett ti tt tt tt 2 S f PIT ITI z 3 alH 3 ST TA 5 T eee S od O gle Tee 0 40 80 120 160 220 0 20 40 60 80 100 120 140150 Output voltage ratio Output voltage ratio E Load power factor versus rated HM Output frequency versus rated output current characteristics output current characteristics 100 HPP INE EE tt 100 e E a CONE garaam co PAE UAN TT E o CL ENNIE 60 a PH a S 0 3 40 3 s HITITITITIT N 20 Li 6 20 nia S 0 Lai 1 10 20 30 40 50 999 9 0 7 08 0G 04 02 0 Output frequency Hz Load power factor For the Output voltage ratio versus rated output current characteristics AC mode and Load po factor versus rated output current characteristics graphs
14. m us ll Please contact our distributors to confirm specifications price accessories or anything that may be unclear when placing an order or concluding a purchasing agreement Issue Jun 2012 2012061KJEC21a
15. nance ability due to the unit configuration The PCR LE series excluding PCR500LE are a unit type configuration The power unit can be serviced replaced by the unit of 1 kVA For system interconnection tests with reverse load flow Conforming to the guideline for requirements of system interconnection technologies Simulated power supply of solar panels PAT T Series 2 m eee o Power conditioner Item under test Load switch route switch Power supply voltage for detector circuit tests PWR Series Power meter KPM1000 Simulated AC loa PCZ100 D EL Interface bus GBIB RS 232C USB LAN etc Simulating reverse load flow Other functions Simulated system AC power supply PCR6000LE fi _ eee 1 a EEE Setting output impedance Measuring harmonics current Soft start Rise time control Internally fixed Vcc Line impedance network All the simulated reverse load flow power is consumed internally thus there will be no reverse load flow to the system Item Model PCRSOOLE PCR1000LE PCR2000LE PCR3000LE PCR4000LE PCR6000LE PCR9OOOLE Input ratings AC rms Voltage 85 Vac to 132 Vac 170 Vac to 250 Vac 1 170 Vac to 250 Vac Phases Single phase Three phase Frequency 47 Hz to 63 Hz Power factor 2 0 97 TYP Max current
16. nd 300 V H range and the load power factor is 1 At the output terminal block When the response mode is set to FAST or MEDIUM 12 Between 40 Hz and 999 9 Hz When the output voltage is between 80 V and 150 V L range or 160 V and 300 V H range and the load power factor is 1 This is the output line regulation with 200 Hz as the reference 13 With respect to changes in the rated range When the output voltage range is 100 V or 200 V and the output current is 0 A 14 With respect to changes in all rated ranges 15 When the output voltage is between 80 V and 150 V L range or 160 V and 300 V H range and the load power factor is 1 16 When the output voltage is 100 V or 200 V the load power factor is 1 and the output current changes from O A to the rated value and from the rated value to 0 A 17 When the input voltage is 100 V or 200 V the output voltage is 100 V or 200 V the output current is the rated value the load power factor is 1 and the output frequency is between 40 Hz and 999 9 Hz 18 With the true rms display a waveform with a crest factor of 3 or less DC output frequency between 40 Hz and 999 9 Hz RMS and AVE 19 When the output frequency is between 45 Hz and 65 Hz 20 Although signals are insulated with output terminals each signal is common Logic setting is also possible ltem Model PCRSOOLE AC POWER PCR L SUPPLY ERIES PCR1000LE General Insulation resistance Withstand voltage Between i
17. nput and chassis output and chassis and input and output Circuit method Between input and chassis output and 500 Vde 30 MQ or more chassis and input and output PCR2000LE PCR3000LE PCR4000LE PCR6000LE PCR9OOOLE 500Vdc 10 MQ or more 1 5 kVAC for 1 minute Linear amplifier system Operating environment Operating temperature range Environmental Storage temperature range Indoor use overvoltage category II 0 C to 50 C 82 F to 122 F 10 C to 60 C 14 F to 140 F Operating humidity range Storage humidity range conditions 20 rh to 80 rh no condensation 90 rh or less no condensation Altitude Up to 2000 m Dimensions chassis See the outline drawing Weight Approx 17 kg Approx 35 kg Approx 55 kg Approx 82 kg Approx 190 kg 37 48 Ib 77 16 lb 121 25 lb 180 78 Ib 211 64 Ib 308 64 Ib 418 88 Ib Input terminal Inlet M4 M5 M8 M8 M8 M5 Output terminal M4 M4 M4 M5 M5 M8 M8 Power cord eras Safety information 1 copy CD ROM 1 disc Complies with the requirements of the following directive and standards EMC Directive 2004 108 EC EN 61326 1 EN 61000 3 2 EN61000 3 3 The maximum length of all cables and wires connected to the PCR LE Series must be less than 3 m Complies with the requirements of the following directive and standard Low Voltage Directive 2006 95 EC 2 EN 61010 1 Class Pollution Degree 2 Electromagnetic compatib
18. ption Example Operation with a 4 kVA model when 1 kVA is necessary PCR4000LE PCR4000LE Excluding PCRS500LE and PCR1000LE External communication RS232C equipped as a standard Remote control available with GPIB USB and LAN as options Using LAN makes it possible to configure highly cost effective systems as LXI standard is supported Memory function It is possible to store up to 99 data sets of the output frequency voltage AC DC and a cyclic waveform under the waveform bank number on the memory of the main unit In addition you can use USB memory devices to store the data contained on the main unit memory panel settings power line abnormality simulations and sequence data Standard supported Usable for systems to test conformance to the IEC61000 3 and 4 Series standards Optional applications software also offered Please refer to the end of the brochure for details AC PowER SUPPLY PCR LE ERIES Front panel serving as a remote control The front panel is detachable With the optional extension cable the panel functions as a remote control You can operate the PCR LE unit installed under your work desk work bench remotely from the front panel connected with the optional extension cable ECO5 PCR Practical example HA Neatly stored under the desk f a o H Gs Depth 595 mm H 430mm Extension cable for control panel 2 m EC05 PCR Downsizin
19. ut voltage frequency and waveform can be changed along the way thus power supply environment testing can be automated In addition to AC output DC output and AC DC output in sequence are also available With the resolution setting by increments of 0 1 ms the system provides functions to set the starting phase sudden phase shift as well as a jump and pause function Sensing Regulation adjustment Even in cases in which load units are installed remotely the voltage RMS value at the end of the load can be stabilized through correction of voltage drops Hardware sensing and software sensing are provided as sensing function allowing you to selectively use either one accordingly with the load condition and application Output current control The current limiting function enables you to control the output current RMS at a certain level for continuous operation by a selectable time setting time continuous for a trip operation Continuity tests for electric facilities distribution panels circuit breakers devices for wiring etc can be performed under stable conditions Eco friendly function Power conservation function E Energy saving operation function You can utilize the energy saving function to operate only the necessary power unit s depending on the required supply load E Sleep function The power unit goes into the sleep mode when no output is detected for a certain time to cut down on the power consum

Download Pdf Manuals

image

Related Search

Related Contents

CDA CW897 User's Manual  Spectra Logic T950 User's Manual    Nicolosi - plesso di Via A. Moro PIANO DI EMERGENZA  ETM/V 214-325 - Jungheinrich  200505035 93-2241 Isobar OM.qxd  istruzioni di montaggio - R5 FF  Mode d`emploi (PDF 1,36 MB)  取扱説明書の表示  Cava de Vino de Empotrar  

Copyright © All rights reserved.
Failed to retrieve file