SV Series Sensor Meter User Manual

image

Contents

1. 41 8A 7 1 0A 51 AA DA DI DAG Ta ial 24V Note If there is any change please refer to the drawing on the Meter COM A B KKSV8WEO01 A 0 4 11 Simple Problem Shooting Dispaly Message Shooting Method Display HHHH Input disconnect or over upper limit please check input signal FH value and ambient working temperature Display LLLL Input disconnect or under lower limit please check input signal FH value and ambient working temperature 12 Communication SV series Sensor Meter following Modbus RTU communication protocol and it can run RS485 half duplex communication Read function code is 0x03 write function code is 0x10 16 bit CRC checking is applied The coulometer can not return error message Data Frame flag Start bit Data bit Stop bit Check bit 1 8 2 None 1 Read Multiple Registers For example The host computer read the float number AL1 The value of Alarm 1 is 14 5 The address code of AL1 is 0x0000 for ALI is float number 4bits it will occupy 2 data register Reference IEEE 754 standard the hexadecimal 16 result of the decimal float number is 0x66667641 Request from the host computer Read Multiple Registers a ae aa aa a Pe a i Start Start Data Data Unit Address Function Code Address Hi Address Lo Length Hi Length Lo CRC Code Lo CRC Code Hi Correct answer from slave unit Read Multiple Registers 1 2 3 4 5 6 7 8 9 F Function Data 1 Data 1 Data 2 Data 2 Uni
2. C 1 C 0 5 F S 3digits gt 100KQ 4 b B 600 1800 C 1 C 0 5 F S 3digits gt 100KQ 5 r R 500 1600 C 1 C 0 5 F S 3digits gt 100KQ 6 5 S 10 1600 C TE 0 5 F S 3digits gt 100KQ 7 m N 50 1200 C 1C 0 5 F S 3digits gt 100KQ 8 Pk PT100 199 9 650 0 C 0 1 C 0 5 F S 3digits 0 2mA 9 CuS CU50 50 0 150 0 C 0 1 C 0 5 E S 3digits 0 2mA 10 Cut CU100 50 0 150 0 C 0 1 C 0 5 E S 3digits 0 2mA 11 au 0 50mV 0 50mV Idigit 0 5 F S 3digits gt 100KQ 12 aA 4 20mA 0 20mA Idigit 0 5 F S 3digits lt 1500 13 n 0 10V 0 10V 0 5 F S 3digits 14 rk 0 4002 0 4002 Idigit 0 5 F S 3digits gt 100KQ 3 Unit and Code Reference Table No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Code A CA aa eG G AG SPA PA bAlAbA a 2 ev lePaAl He jen att tt ett aa AeA e ee ce or cm mm Mpa pa ba KHz ka Q KQ C F 4 Panel Indication AL1 Alarm Indicate Light a AL2 Alarm Indicate Light HJ Parameter Display Window Unit Code SET Function Key Menu Modify Key SHIFT SV8 DIGITAL METER PV Display Window Increase Key Decrease Key KKSV8WEO1 A 0 2 5 Operation Sequence 1 SET Key Under measuring status short press SET key to enter into primary setting menu long time press SET key can enter into advanced setting menu press SET key
3. check the connection number while you connect the power supply wire or input signal otherwise it may cause fire A Caution 1 This product cannot be used outdoors Otherwise the working life of the product will become shorter or an electric shock accident may happen 2 When you connect wire to the power input connectors or signal input connectors the moment of the No 20 AWG 0 50 mm2 screw tweaked to the connector is 0 74n m 0 9n m Otherwise the connectors may be damaged or get fire Please comply with the rated specification Otherwise it may cause electric shock or fire and damage the product 4 Do not use water or oil base cleaner to clean the product Otherwise it may cause electric shock or fire and damage the product 5 This product should be avoid working under the circumstance that is flammable explosive moist under sunshine heat radiation and vibration Otherwise it may cause explosion 6 In this unit it must not have dust or deposit otherwise it may cause fire or mechanical malfunction 7 Do not use gasoline chemical solvent to clean the cover of the product because such solvent can damage it Please use some soft cloth with water or alcohol to clean the plastic cover ies Ww KKSV8WE01 A 0 1 1 Model SV Ww W Design Code Input amp Communication 10 Single Input without RS485 Communication 18 Single Input with RS485 Communication should be or
4. FH 200 HS i 1 Alarm Hysteresis Value 0 FH 1 Ad 1 Alarm Mode 1 Absoult Lowest Limit Alarm 2 Absoult Highest Limit Alarm 1 2 1 ALe 2 Alarm Setting Value FL FH 600 He 2 Alarm Hysteresis Value 0 FH 5 Acc 2 Alarm Mode 1 Absoult Lowest Limit Alarm 2 Absoult Highest Limit Alarm 1 2 2 PS PV Measuring Value Modify 1999 9999 0 roy LOCK Key LCK 0001 only modify alarm value 0 9999 Br LCK 0010 all the parameters can not be changed except LCK menu 0 8 High Advanced Menu Setting Parameter Name Illustration Setting Range EX Factory Setting i aP Input Signal Type Reference Table K EL Input Signal Display Low Limit Reference Table 50 FH Input Signal Display High Limit Reference Table 1200 JP Decimal Point Setting display only for Voltage Ampere and Resistance signal input 0 3 0 Fe Filtering Value The larger for the vlaue the slower for the change on the Meter The smaller 0 255 255 for the value the quicker for the change on the Meter bri Display Value for the Analog Low Limit FL FH 50 brch Display Value for the Analog High Limit FL FH 1200 bufid RS485 Communication Baud Rate 4800 9600 9600 Addr RS485 Communication Meter Address 1 255 1 KKSV8WEO01 A 0 3 Alarm Function Table Alarm No Alarm Type Alarm Output AL1 AL2 mutual independence 1 8 LILLLLL LV Absoult Low Limit Alarm HY Temperature Decrease AL 2 Absoult High Limit Alarm SW Temperature Increase 9 Dim
5. Refer to The Operation User Manuel Note Alarm Mode Alarm Type Low Limit Alarm High Limit Alarm Alarm Status ON OFF Reference 1 2 Reference 1 0 Note Input Signal Input parameter meter Note 8 Code and Value reference table refer to unit code reference table Acquiring Schedule of 16 units CRC code unsigned int Get_CRC uchar pBuf uchar num unsigned i j unsigned int wCre OxFFFF for i 0 i lt num i t wCre unsigned int pBuf li for j 0 j lt 8 j if wCre amp 1 wCre gt gt 1 wCre 0xA001 else wCre gt gt 1 return wCrc KKSV8WEO01 A 0 6
6. SV Series Sensor Meter User Manual Features TC RTD Analog Signal Universal Input Multi Display Units can be choosed With Display Alarm and Current Transmit function With RS485 Communication Function Power Supply 100 240VAC For your safety please read following Notice Information carefully before you are using our product m Safe Caution X Please read the manual carefully before you use the temperature controller X Please comply with the below important points A Warning An accident may happen if the operation does not comply with the instruction A Notice An operation that does not comply with the instruction may lead to product damage X The instruction of the symbol in the manual is as below A Anaccident danger may happen in a special condition A Warning 1 A safty protection equipment must be installed or please contact with us for the relative information if the product is used under the circumstance such as nuclear control medical treatment equipment automobile train airplane aviation and equipment etc Otherwise it may cause serious loss fire or person injury 2 A panel must be installed otherwise it may cause creepage leakage Do not touch wire connectors when the power is on otherwise you may get an electric shock 4 Do not dismantle or modify the product If you have to do so please contact with us first Otherwise it may cause electric shock and fire 5 Please
7. again long time pressing can return back to measuring status SET key should be pressed after each parameter be modified 2 lt q SHIFT key Under measuring status short time press lt key PV window will show Unit then press Akey to choose the display unit M cm mm kg g mg Mpa pa ba Mba n W KW RPM Hz KHz mV V KV mA KA Q KQO C F When the input signal is TC Unit just can be choosed from C and F when modify the menu short press lt key can let the value which need be modified flash from right to left when the value flash press A key and W key can make change on the value 3 Aly Key Press A key the value will increase press W key the value will decrease 4 If there is no operation for some time the meter will return back to the measuring status automatically 6 Operation ge S Power On SHIFT a Y SET Measuring aT gt mar Status gt eee Input Signal Type BEA noi Address Unit Setting SET Long time press SET ALI 260 Alarm 1 SET E Alarm 1 Hysteresis SET Mida Alarm 1 Model SET Le oscs Alarm 2 SET AE Alarm 2 Hysteresi ER E A Display Lowest limit of Analog anas Alarm 2 Model ect SET Display HIghest limit of Analog PV Modify Value SET Baud Rate SET LOCK 7 Primary Menu Setting Parameter Name Illustration Setting Range EX Factory Setting AL i 1 Alarm Setting Value FL
8. dered Alarm C Two Alarm 2 Model Indication Output Function R No 4 20mA current output Size W H mm 4 48 48 6 48 96 7 72 72 8 96 48 9 96 96 SV Series Sensor Meter D 4 20mA DC current output Model Alarm 4 20mA current transmit RS485 SVLI RC1OW 2 NO NO SVLJ DC10W 2 YES NO SVU RC18W 2 NO YES SVLI DC18W 2 YES YES 3 Main Technical Specification 1 Whole Meter Parameters Power Supply 100 240V AC DC Total Curretn lt 30mA 220VAC 50Hz Analog Output 4 20mA current output Load resistance 600Qmax Alarm Output Relay output load ability 1A 230VAC Auxiliary Voltage Output DC 24V 30mA Dielectric Strength Dielectric strength between power supply terminal Relay terminal and Signal input termial over than 2000VAC 50HZ 1Minute Communication RS485 Modbus RTU Protocol Protective Level IP65 Working Environment 0 50 C 45 80RH Storage Environment 10 60 C 25 85RH 2 Input Parameters No Code Input Type Measuring Range Resolution Accuracy Input Resistance 0 E K 50 1200 C 1 C 0 5 F S 3digits gt 100KQ 1 d J 0 1200 C 1 C 0 5 F S 3digits gt 100KQ 2 E E 0 850 C 1C 0 5 F S 3digits gt 100KQ 3 k T 50 400
9. ension and Installation POWER 100 240V AC DC AL1 AL2 1D D3 T 15 TI a TC mV mA V N RTD Rt Side Face Size Mounting Size Face Size GE nH ion A Ta 0 Joe K Size A B C D E F G H Min J K Min 4 48 48 48 48 97 5 3 94 5 45 45 5 25 45 5 25 6 96 48 48 96 97 5 3 94 5 89 5 45 25 90 25 7 72 72 72 72 97 5 3 94 5 67 67 5 25 67 5 25 8 48 96 96 48 97 5 3 94 5 44 5 90 25 45 25 9 96 96 96 96 97 5 3 94 5 91 5 92 25 92 25 80 80 160 160 80 96 13 83 75 5 155 5 30 76 30 16 160 80 80 160 96 13 83 155 76 30 155 5 30 10 Connection Drawing SV4 SV6 SV7 mm TG m mA V TC mV na V oer cir AL 1 J Y y sl 2 acy 190 240v RTD Rt AL2 B A KA RTD Rt RTD Rt AA A p l A eet QH 10 1H2H3H4H5 H6 Ha SVNT Ae 1X2 4K3 44 X5 DKK XG nas ae Bal oom n oO DAA MS TRSA 1112131 A15 189 4920 DEMEDEN Q O 9 a i asas a a a ee 1 3 5 sri GOW AE EBS POWER ALI 24V re 100 240V 4 20mA V V AC DC POWER 24V 100 240V 4 20mA AC DC SV8 sv9 ye 4 20mA POWER B A COM 24V ee com AL2 ALI Neve rsa rt I A i A 1 2 X3 X4 5 X6 gt DZOA 5yX4 X3 X2 X1 o Fo o e 19
10. t Add Data Byte No High byte High byte PAF sales alae 2 Write Multiple Registers For example The host computer read the float number AL1 The value of Alarm 1 is 60 The address code of AL1 is 0x0000 for ALI is float number 4bits it will occupy 2 data register Reference IEEE 754 standard the hexadecimal 16 result of the decimal float number is 0x66667641 Request from the host computer Read Multiple Registers cn NEBr dN Yet eB eS yee eto a ie I 8 Unit Function start Start Data Data Data Data 1 Datal Data2 Data2 CRC CRC Address Code Address Hi Address Lo Length Hi Length Lo Byte No High byte Low byte High byte Low byte Code Lo Code Hi 0x01 0x10 0x00 0x00 0x00 0x02 0x04 0x00 0x00 0x16 0x44 OxFD OxFC Correct answer from slave unit Write Multiple Registers Co ee Se ee ei e i _ Unit Address Start Start Dat Dat Function Cod ara oe i unction Code Address Hi Address Lo Length Hi Length Lo CRC Code Lo CRC Code Hi SV Series Meter Address Reference Table Data i No Address Name Type Number Read Write Note 2 ooo rrenean to ew d 2 ooo orema oe ew d ooo azam neeese tow ew 0 _ o oos senmenn tow ew d KKSV8WEO01 A 0 5 No Address Name Type Read Write R W R W R W R W R W R W R W R W 0x0012 float 0x0013 float 0x0014 o 0x0033 float R Read Only R W Read Write For Each Parameter s Setting Range Please