Home

DC COMPRESSOR MOBILE FRIDGE USER MANUAL Grape

image

Contents

1. Gra pe Solar GS UF 3 7 Fab1 Reference Manual Rev 130515 Clean Power Today DC COMPRESSOR MOBILE FRIDGE USER MANUAL Grape Glacier 3 7 PLEASE READ THIS USER MANUAL CAREFULLY BEFORE USING WARMING The appliance must be earthed and connected to a suitable DC12V or DC24V socket at lease 120W DC The manufacturer and the seller do not accept responsibility for any damage due to incorrect electrical installation MOVEMENT AND INSTALLATION When moving the unit the angel between the cabinet and the ground should not be less than 45 in order to protect the compressor and refrigerating system Position the unit in a dry and well ventilated place Keep the freezer away from direct sunlight heaters and corrosive gases The normal operation of the unit depends on the heat radiation of the condenser For the initial use the pack ing foam must be taken off and at least 150mm space must be left around the unit TEST RUN The voltage range required is DC12V 10 or DC24V 10 If the power is not stable the unit will not run The unit will restart when the voltage is normal Do not pull the appliance by power cord Connect power set the digital thermostat to 18 C and check the indicators 30 minutes later open the door and check the inside surface If the inside surface is cold your appliance is working FOODS STORING Fresh foods should not be stored together with frozen foods When the temperature is set below 0 C the
2. efrigerant has leaked but inner liner does f Contact your service agent not get cold The system is blocked The inner liner is The door is being opened very cold and the and closed too frequently as little as possible compressor runs con The condenser is not well tinuously ventilated place The controller is faulty the The compressor does power indicator is not on not run The thermostat is set too Re set the temperature high while the ambient is too cold The unit is not placed Make the unit level The unit is noisy properly Some parts have come loose Contact your service agent The pipes are touching Contact your service agent Gra pe Solar GS UF 3 7 Fab1 Reference Manual Rev 130515 Clean Power Today MAIN TECHNICAL PARAMETER DCI Efficient volume 110L DEoOW Temperature of freezing Temperature of refrigerating 0 10C Dimension WxDxHmm 473 498 815 ELECTRICAL DIAGRAM WIRING DIAGRAM THERMOSTAT te rc Loud DC 12V 24V
3. unit is used as a freezer do not store any glass bottled drinks such as beer and lemonade as the bottles might crack Copyright 2012 Grape Solar Inc All Rights Reserved Gra pe Solar GS UF 3 7 Fab1 Reference Manual Rev 130515 Clean Power Today DEFROSTING AND DE ODORIZING When the ice layer on the inner cabinet sides is over 5mm defrosting operation should be performed to im prove the refrigerating efficiency Disconnect power remove all items and clean unit After defrosting clean with a soft rag and switch the ap pliance on Note Never remove ice with sharp objects Place charcoal in the appliance to remove any bad odors MAINTENANCE AND REGULAR CLEANING Always disconnect the power supply before cleaning Clean the inside cabinet whenever necessary Use a warm solution of water and bicarbonate of soda 1 table spoon to every 2 liters of water dry with a soft cloth Dirt from the condenser should be cleaned by a qualified technician when necessary NOT A MALFUNCTION It is normal to hear gurgling sounds caused by the flow of refrigerant when each cooling cycle ends The surface temperature of the compressor can reach 70 90 C when running The noise emitted by the cooling fan on the condenser is a normal condition TROUBLESHOOTING The compressor runs The voltage is not in the nor Switch off power and restart for 1 to 5 minutes mal range when power is normal and stops The compressor runs The r

Download Pdf Manuals

image

Related Search

Related Contents

American Power Conversion Generator User's Manual  Bedienungsanleitung DS-2 RF  section 3 signal description  RefSet CreateUpload – Vulcan Lava Script User Manual Contents    FROSTIG  Product Catalog Spring 2003 - Delta  Seguro de Saúde  

Copyright © All rights reserved.
Failed to retrieve file