Home

Technical Specifications

image

Contents

1. 2 Electric Power Data Acquisition System A 1 Hardware A 1 1 1 EPIB Electric power interface box dimensions 300 x 120 x 180 mm approx Page 22 of 60 ITEM DESCRIPTION AND SPECIFICATION Interface that carries out the conditioning of the diverse signals that can be acquired in a process for their later treatment and visualisation Front panel separated in two left hand part for VOLTAGE sensors and right hand part for CURRENT sensors 8 analog input channels Sampling range 250 KSPS Kilo samples per second 4 Tension sensors AC DC 400V 4 Current sensors A 1 1 2 DAB Data acquisition board PCI Data acquisition board National Instruments to be placed in a computer slot Bus PCI Analog input Number of channels 16 single ended or 8 differential Resolution 16 bits 1 in 65536 Sampling rate up to 250 KSPS Kilo samples per second Input range V 10V Data transfers DMA interrupts programmed 1 0 Number of DMA channels 6 Analog output O Number of channels 2 Resolution 16 bits 1 in 65536 Maximum output rate up to 833 KSPS Output range V 10 Data transfers DMA interrupts programmed 1 0 Digital Input Output Number of channels 24 inputs outputs DO or DI Sample Clock frequency 0 to 1 MHz Timing Counter timers 2 Resolution Counter timers 32 bits A 2 Data Acquisition Software Data Acquisition Software with Graphic Representation Amicable
2. 3x 4x7 pF 400V 4 DC Shunt Series Compound Excitation Motor Power 250 300W Speed 3000 r p m V excitation 220 V D C l Excitation nominal 0 3A V Armature 200V D C Armature nominal 1 5A 5 AC Synchronous Alternator Motor Power 250 300W Speed 3000 r p m Frequency 50Hz Connections Star triangle V excitation nominal 220V D C Excitation nominal 0 59A V Armature 3x220 380V 6 Three Phase Asynchronous Motor Squirrel Cage 750rpm 8poles 550w Power 250 300W Speed 2769 r p m 50Hz 3330 r p m 60Hz Connections Star triangle Frequency 50 60 Hz V Armature 230 400V 50Hz 250 440V 60Hz Armature nominal 1A 0 7A 7 Three Phase Asynchronous Motor with wound Rotor Power 300W Speed 1413 r p m Frequency 50Hz V Armature 230 400V Armature nominal 1A 0 7A 8 Single Phase Asynchronous Motor with Starting Capacitor Power 370W Speed 2800 r p m Frequency 50Hz V Armature 230V Armature nominal 1 5A 9 Single Phase Universal Motor Power 4 8W Speed 480 14000 r p m Frequency 50Hz Page 27 of 60 ITEM DESCRIPTION AND SPECIFICATION 10 Single Phase Asynchronous Motor with Starting and Running Capacitor Zz V Armature 230 240V Power 250W Speed 2800 r p m Frequency 50 Hz V Armature 230V 11 DC Motor Speed Controller Metallic box Regulated voltage output up to 320 Vdc Maximum current output 2 A Front panel including Connections Positive
3. C Operating humidity IEC 60068 2 56 10 to 90 RH noncondensing Storage humidity IEC 60068 2 56 10 to 90 RH noncondensing Maximum altitude 2 000 m Pollution Degree IEC 60664 2 Indoor use only PO 92 Personal Computer with Complete Accessories with UPS o OE Oo Core i3 3240 4GB 1TB Windows 7 with 19 5 inch LED monitor or better Po 93 Students Chairs Storage Cabinets amp Multimedia Devices 1 Lot PO Polypropylene Stacking Chair 45pcs Chair seat amp back high quality polypropylene Chair frame Round steel tube heavy duty high quality electro static powder coated Page 59 of 60 ITEM DESCRIPTION AND SPECIFICATION eee Stacks 10 high from the floor Color Navy blue dark blue Storage Cabinet 2pcs 1 20m x 1 90m Sliding Glass doors on powder coated aluminum frame with lock 18mm laminated boards with PVC edging Storage Cabinet 1 1 20m x 1 90m Sliding Glass doors on powder coated aluminum frame with lock 18mm laminated boards with PVC edging Interactive Whiteboard 1 78 diagonal surface 4 pens wand wall mount USB Interface computer connection Workspace software Infrared Technology pen amp finger touch with Windows Mac or Linux Multi touch with Windows 7 aspect ratio 4 3 8000x8000 resolution Android amp IOS tablet compatible Multimedia Projector 1 USB 3LCD Projector 2800 or better Lumens White and Colour Light Output Computer Cable USB A USB B Cables Remote Contro
4. Echo pulse positive pulse 115 microS to 18 5 ms Echo holdoff 750 micros from fall of trigger pulse 2 Burst frequency 40 kHz for 200 microS Burst indicator LED shows sensor activity Delay before next measurement 200 microS Size HxWxD 2mmx46mmx16mm 3 DC Motors Supply voltage 12V Torque 300 oz in RPM 152 Encoders Supply voltage 5V Cycles per revo 100 CPR Pulses per revo 400 PPR 4 NI sbRIO 9632 Network Network interface 10 BaseT and 100BaseTX Ethernet Compatibility IEEE 802 3 Communication rates 10 Mbps 100 Mbps auto negotiated Max cabling distance 100 m segment 5 RS 232 DTE Serial Port Baud rate support Arbitrary Max baud rate 115 200 bps Data bits 5 6 7 8 Stop bits 1 2 Parity Odd Even Mark Space None Flow control RTS CTS XON XOFF DTR DSR None peed 0 9611 9631 9641 266 MHz 0 9612 9632 9642 and NI sbRIO 96x2XT 400MHz 7 Memory Non volatile Memory RIO 9611 9631 9641 128 MB RIO 9612 9632 9642 and NI sbRIO 96x2XT 256 MB m memory RIO 9611 9631 9641 64 MB RIO 9612 9632 9642 and NI sbRIO 96x2XT 128 MB ilinx Spartan 3 igurable FPGA Number of logic cells RIO 9611 9631 9641 17 280 NI sbRIO 9612 9632 9642 and NI sbRIO 96x2XT 46 080 Available embedded RAM NI sbRIO 9611 9631 9641 432 kbits NI sbRIO 9612 9632 9642 and NI sbRIO 96x2XT 720 kbits 9 3 3 V Digital I O Number of DIO channels 110 Max tested current per channel 3 mA Max total current all lines 330 mA Max tested DIO
5. ITEM DESCRIPTION AND SPECIFICATION ee 9 Comparator Positive switching comparator with hysteresis The inputs are short circuit proof or surge proof to 24 V 2 separate inputs IN A IN B each acting on two independent comparators Each comparator can be set to e Reference voltage 10 10 V Hysteresis 0 5 V e Input voltage inputs A and B 10 10 V e Input resistance inputs A and B gt 10 kQ e Display accuracy 30 mV e Outputs A and B Floating relay contacts changeover contacts e Contact load 24 V DC 2 A and 120 V AC 1 A Consisting of Bus bar mass flow rail contact for 4 mm security plugs mounting with protection against accidental contact with a built in lock grid ledge in the fixture for electrical port and control unit or else with plug in adaptors for the profile plate 10 Pressure sensor analog e Pressure measuring range 0 1000 kPa 0 10 bar e Maximum permissible pressure 1400 kPa 14 bar e Power supply 12 30 V DC e Output signals Voltage output 0 10 V e Frequency maximum 100 Hz e Electrical protection Short circuit proof polarity reversal protected The sensor will also supply a signal at pressures of lt 0 bar Linearity and proportionality cannot be guaranteed in this case 11 5 3 way solenoid valve mid position closed_ Pilot actuated spring centred piston spool valve with non detenting and detenting manual override and LED e Electrical conn
6. e Grade of filtration 5 um Condensate quantity 43 cm3 e Connector G 1 8 QS 6 for plastic tubing PUN 6 x 1 Input pressure 1000 kPa 10 bar Operating pressure 600 kPa 6 bar Differential pressure 100 kPa 1 bar 6 Manifold Manifold with eight self closing non return valves A common manifold QS 6 for plastic tubing PUN 6 x 1 allows supply of compressed air to the control via eight individual ports QS 4 for plastic tubing PUN 4 x 0 75 e Connector G 1 8 7 Plastic tubing Very flexible and pressure secure PUN 4x 0 75 e Exterior diameter 4 mm e Interior diameter 2 6 mm PUN 3x0 5 e Exterior diameter 3 mm e Interior diameter 2 1 mm PUN6x1 e Exterior diameter 6 mm e Interior diameter 4 mm e Differential inputs e Comparators e Final control elements positional control elements speed control elements acceleration lcontrolelements status controller proportional control elements integralcontrol elements differential control elements PID controller e Overall gain Status controller e Correcting variable offset e Summing junction Limiter Output Technical data e Overmodulation indicator 10 gt Ue gt 10 V e Input voltage range 13 13 V e Output voltage limitation 0 10 V 10 10 V e Correcting variable offset 5 3 5 V at 0 10 V 0 7 Vat 10 10 V Proportional coefficient KP 0 1000 e Integral coefficient KI O 1000 s 1 Page 54 of 60
7. 10 V DC e Pneumatic connection via QS 4 push in fitting e Pressure measuring range 0 1000 kPa 0 10 bar e Quick Fix safety and quick connector system for slotted profile plates 11 One way flow control valve 4 Design One way flow control valve e Pressure range 20 1000 kPa 0 2 10 bar e Nominal flow rate in flow control direction 0 85 l min in open direction 100 110 l min 12 Single acting cylinder 1 Single acting cylinder with control cams e Design Piston cylinder e Operating pressure Maximum 1000 kPa 10 bar e Stroke length Maximum 50 mm e Thrust at 600 kPa 6 bar 150 N e Spring return force minimal 13 5 N 13 Double acting cylinder 2 Double acting cylinder with control cams End position cushioning with two adjusting screws A permanent magnet is mounted on the cylinder piston Its magnetic field can trigger a proximity switch e Design Piston cylinder e Operating pressure Maximum 1000 kPa 10 bar e Stroke length Maximum 100 mm e Thrust at 600 kPa 6 bar 165 N Return thrust at 600 kPa 6 bar 140 N 14 Start up valve with filter control valve 1 Filter control valve with Pressure gauge and Start up valve mounted on adapter with ajustable angle The Start up valve pressures exhausts the connected pressure zone e Design sintered filter with water separator and piston regulator e Standard flow 120 l min e Pressure regulation range 50 700
8. Analogue input 0 10 V On off valve with filter regulating valve e Filter regulator with pressure gauge on off valve quick push in connections and quick couplings mounted on a swivel support Pneumatic slide module Profile plate connector Recognition module e comprises two different sensors and a mounting bracket e Power supply 24 V DC e Switch outputs PNP normally open contact e Connection cable 3 pin e Capacitive sensor 2 8 mm adjustable e Optical sensor up to max 400 mm adjustable Retro reflective sensor Station link receiver Slide module e universally mounted on a profile e can be adjusted by means of the flow control valve on the underside of the slide e Length 220 mm e Operating pressure 600 kPa 6 bar Workpiece set Cylinder bodies Processing Station PLC Board Control Panel Work pieces Power Supply PLC software Programming cable Drilling operation Page 32 of 60 DESCRIPTION AND SPECIFICATION e Power supply 24 V DC e 8 digital inputs e 8 digital outputs Trolley e Height incl castors to bottom edge of profile plate 750 mm e Width 350 mm Depth 700 mm Control console e Fully assembled with operating panel communication panels spare panel and mounting frame with SysLink connector P i e Membrane keyboard Start pushbutton with LED Stop pushbutton Reset pushbutton with LED 2 flexibly assignable control lamps 4 mm safety sockets with LED status dis
9. F Password Setting 001 999 Automatic dormant temperature 200 C Dormant setting 1 99 min Temperature accuracy 10 C Temperature stability 2 C static working mode Tip to Ground Impedance lt 2 Ohm Tip to Ground Voltage lt 2 mV Size 168 L x 110 W x 95 H Weight 2 5KG Set of Tools set of pliers wire stripper screw driver set PO e 26 hands on projects in Electronics Engineering e Menu driven navigation through the labs e Student registration Interactive representation of circuits in each hands on project e Step by step instructions for students e Interactive study guide for each experiment e Preassembled board with 26 circuits e Representation of experimental results on the screen graphs scope signals numeric indicators Export of results in MS Excel format DC circuits 1 Voltage source in electric circuits 2 Light sensitive resistors photoresistors Page 16 of 60 ITEM DESCRIPTION AND SPECIFICATION Kirchhoff s circuit laws Electric power performance factor source and load matching Ohm s law 3 4 5 6 Series connection of resistors 7 Parallel connection of resistors 8 Resistive voltage dividers 9 Temperature sensitive resistors thermistors 10 Voltage dependent resistors varistors 11 Charging and discharging of capacitors AC circuits Parallel connection of capacitors Series connection of capacitors AC circuits with capacitors Volta
10. Fault Simulation for Pressure Control Loop Four 4 Fault Simulation for Temperature Control Loop wo 2 Fault Simulation for Pneumatic Systems Multiple Parametric or Software Fault Simulations with and outs Book Primary controller Intel Core i5 2450M processor 3 MB L3 cache 2 5 GHz with turbo boast up to 3 2 3 3 GHz 4GB DDRIII 500GB Training media including easy port web based training program fundamentals of open and closed loop control 90 Advance Motor Control Workstation Automation Controller Workstation consist of the following 1 2 3 u 4 5 6 7 8 Variable Frequency Drive Push Buttons Indicators Analog Input Analog Meter Power Supply compact Controller with integrated USB Ethernet IP Port and SD memory Certified nder Ethernet IP Digital I O modules and analog output modules Remote O Ethernet Adapter Touch Screen Interface 6 Primary controllers for wireless communications With Control Software for multiple user Data Acquisition Device NI myRIO University Bundle incl Starter Kit and Mechatronics Kit 1 set 10 u nits With built in LABView Software Specifications Typical between 0 to 40 degrees Processor type Xilinx Z 7010 speed 667 MHz cores 2 Memory Nonvolatile memory 256 MB DDR3 memory 512 MB DDR3 clock frequency 533 MHz DDR3 data bus width 16 b Radio mode lEEE 802 11 b g n Frequency band ISM 2 4 GHz Channel width 20 MHz Ch
11. e Workpiece positions 6 e Diameter 350 mm e Height 125 mm e Nominal voltage 24 V e Nominal rotational speed 6 r p m with series resistor 47 e Nominal current 0 15 A with series resistor 47 e Nominal current 0 5 A e The end positions 6 x 60 can be sensed by means of an optional inductive sensor An optional capacitive sensor for workpiece sensing can also be mounted under each workpiece position Sensor inductive e Inductive sensor for end position interrogation on the rotary indexing table Nominal switching distance 2 5 mm e Power supply 24 V DC e Switch output PNP normally open contact e Connection cable 3 pin Sorting gate module electrical C34 Branch module electrical For mounting on a profile plate Voltage 24 V DC Rating 7 WFor mounting on a profile plate An electrical solenoid is used for the drive e Voltage 24 V DC e Output 7 W Station link receiver Testing module e consists of a solenoid probe with an inductive sensor for sensing Page 33 of 60 i e used for the testing of workpieces simple drill hole checking simple height checking workpiece position checking Solenoid actuator e Working stroke 10 mm e Voltage 24 V DC e Output 7 W Inductive sensor e Nominal switching distance 2 5 mm e Power supply 24 V DC e Switch output PNP normally open contact e Connection cable 3 pin 4 Handling Station PLC Board Control Panel Work pieces Power Supply PLC soft
12. magnetically operated e Connection via 4 mm safety connectors e Switching output N O contact PNP with switching status indication e Overload and short circuit proof with reverse polarity protection e Operating voltage 5 30 V DC e Output current max 100 mA e Switching time on off max 1 ms e Mounting system for T slot 19 Hose line with quick release couplings The high pressure hose consists of three layers The innermost layer is synthetic rubber followed by a wire mesh and sheath of abrasion resistant synthetic rubber The quick coupling sockets are self sealing when decoupled Used with a coupling nipple the coupling sockets form a tightly sealed connection Only the face of the coupling is coated with oil during the coupling process Coupling and decoupling are only permissible when the hose is de pressurised Page 52 of 60 ITEM DESCRIPTION AND SPECIFICATION e Operating pressure 6 MPa 60 bar e Max permissible pressure 12 MPa 120 bar e Temperature range 40 125 C e Min bending radius 100 mm e DN 06 6 3 mm 20 4 mm Safety laboratory cables 106 pieces red blue and black Complete set consisting of 106 safety laboratory cables with 4 mm safety plugs in the colours red blue and black e 10x red 50 mm 10x blue 50 mm e 8x black 50mm 8x red 300 mm e 8x blue 300 mm e 18x black 300 mm e 8x red 500 mm e 8x blue 500 mm e 18x black 500 mm e 2x red 1000 mm e 3x blue 1000 mm 2
13. recoverable KIT contents of the following e Manuals Set of practice wires e 11 C LM318 e 11 C OPO7 e 6 I C UA741 operational amplifier e 16 bypass ceramic capacitors 100nF e 6 switches 2 positions e N button potentiometers 100K e 1 button potentiometer 50K 2 button potentiometers 5K e 1 vertical multi turn potentiometer 10K This kit is designed to be able to do the following practices Dimensions 300 x 300 x 200 mm Page 10 of 60 ITEM DESCRIPTION AND SPECIFICATION e 1 resistance 100 ohms e 6 resistances 100K e 3 resistances 10K e 2 resistances 15K e 2 resistances 1K e 2 resistances 200K e 1 resistance 300K e 3 resistances 30K e 2 resistances 50K Dimensions 300 x 300 x 200 mm approx EXPERIMENTS POSSIBILITIES This kit is designed to be able to do the following practices Operational amplifier characteristics Operational amplifier study Closed loop output compensation voltage Operational amplifier fault study The inverting amplifier nverting amplifier study nverting amplifier fault study The non inverting amplifier O O Study of the non inverting amplifier Voltage follower Fault study in the non inverting amplifier The adder amplifier Adding amplifier study Fault study in the adding amplifier The differential amplifier Differential amplifier study Differential amplifier fault study Comparators Comparator study Comparato
14. 3 pcs Angle Grinder 2kW Angel grinder 4 Deadman switch Page 4 of 60 ITEM DESCRIPTION AND SPECIFICATION Po Specs welding mask heavy duty faceshield visor heavy duty welding apron heavy duty io erouna clam 300 Amps E Civil Works Program of Works Detailed Cost Estimates Drawings etc 12 Laboratory Repairs Renovation b 1 for MUST Campus Lab b 2 for Jasaan Campus Lab pls see details in approved EDP Note All packages should come with complete training program laboratory manuals workbooks Training Details Description No limit of the number of participants Duration of training a Augmented Welding simulator 5 days during the contract period b Actual Welding Machines 2 days LOT 3 39 717 835 00 Including Civil Works P 309 835 00 3 1 Eelctrical and Electronics Circuits Laboratory C POWER SUPPLY A TECHNICAL DATA 1 Metallic box 2 Fixed outputs 5 V 12 V 1 A 3 Variable outputs 12 V 0 5 A 4 AC output 12V or 24 V 5 Outputs through either 2 mm contact terminals or through 25 pin CENTRONICS connectors 2 outputs 6 LED s voltage indicators 7 Robust construction 8 Supply 110 220V A C 9 Frequency 50 60 Hz 10 Includes all the requirements for full working with any kit 11 Dimensions 225 x 205 x 100 mm approx Weight 2 Kg approx DEVELOPMENT MODULE A TECHNICAL DATA 1 This is a module to build and implement student s own
15. 700 kHz Over voltage protection Al channel 24 V one channel only AISENSE 24 V CMRR DC to 60 Hz 62 dB 120 ppm of full scale step 8 LSB 4 uS convert interval 5 5 uS from 50 to 850C pO 30 ppm of full scale step 2 LSB 8 uS convert interval Analog triggers Number of triggers 1 Resolution 10 bits 1 in 1 024 Bandwidth 3 dB 700 kHz Accuracy 1 of full size 11 Analog Output NI sbRIO 963x 9632XT and NI sbRIO 964x 9642XT Only Analog input channels 4 DAC resolution 16 bits Type of DAC string Output range 10V Operating Voltage Nominal 10 7 V Minimum 10 3 V Maximum 11 V Current drive 3 mA per channel Output impedance 10 V Stability Offset drift 80 uV oC Gain drift 6 ppm oC Protection Overvoltage 25 V at 25 oC Short circuit indefinitely Power on voltage 0 V Update time One channel in use 3 ps Two channels in use Sus Three channels in use 7 5 us Four channels in use 9 5 us Noise Updating at 100 kS s 600 Vrms Not updating 260 Vrms Slew rate 4 V s Crosstalk 76dB Setting time 100 pF load to 1 LSB FS step 20 us 3 V step 10 us 0 1 V step 8 us Glitch energy 256 steps worst case 2 mV for 2 us Capacitive drive 1 500 pF min Monotonicity 16 bits Differential nonlinearity 1 to 2 LSBs max Integrated nonlinearity endpoint 16 LSBs max 12 Power Limits 5 V pins P2 P3 P4 P5 5 V 5 2 A max shared with C series modules 13 Power Requirements Power supply vol
16. B75 Express Chipset Memory 2x2GB DDR3 1333MHz up to 16GB max support on 4DIMMs slots Hard Disk 500GB Sata up to 2TB maximum capacity Video Card ADV Galaxy GeForce GT630 2GB 128 Bit DDR3 HDMI DVI VGA Optical Drive 16x SuperMulti Drive Video Integrated Intel HD Graphics Solution Audio Embedded high defination with 5 1 channel surround sound support LAN Gigabit Ethernet 10 100 1000 Expansion PCI Express 2 0x16 slot PCI Express 2 0x1 slot Parallel Port with Parallel Port Keyboard and Mouse USB Keyboard amp USB Optical Mouse Speaker Internal Speaker Operating System FQC 05919 Win Professional 8 Win 32 Eng Intl 1 pk DSP OEI DVD UPS APC BK650AS 650VA UPS Monitor AOC E1621SWB 15 6 LED Monitor WA ROUTER tunit 300Mbps MULTIMEDIA PROJECTOR 2 units USB 3LCD Projector 2800 or better Lumens White and Colour Light Output Computer Cable USB A USB B Cables Remote Control Soft Carry Case amp Manual FURNITURE 1 Teacher s Table 2 units Dimension 1 5m Length x 0 50m Width x 0 76m Height Phenolic top 0 25mm thickness Epoxy coated steel tubular base brackets and frames with adjustable leveler 2 Student Working Table 7 units Dimension 1 5m Length x 0 50m Width x 0 76m Height Phenolic top 0 25mm thickness Epoxy coated steel tubular base brackets and frames with adjustable leveler 3 Executive Chair for teacher 2 e Executive type e Non Folded e Finished Material
17. Depth 700 mm Control console e Fully assembled with operating panel communication panels spare panel and mounting frame with SysLink connector e Membrane keyboard Start pushbutton with LED Stop pushbutton Reset pushbutton with LED 2 flexibly assignable control lamps 4 mm safety sockets with LED status display for simple I O connection Syslink and Sub D sockets for connection to PLC of choice are available on the rear panel e fully assembled with AS interface control console communication panels spare panel and mounting frame with AS interface connector Programmable Logic Controller EduTrainer Universal Preferred versions MPS MPS PA A4 rack with built in power supply 24 V DC power supply integrated pO 32 bit MIPS processor 400 MH e Data memory 32 MB flash 32 MB 20 MB flash 8 MB RAM user memory 32 KB non volatile memory e Communication network Ethernet 10 100 Base T e Integrated web server e Master CANopen e Diagnostic handheld for CPX terminal can be connected e 1 set Desktop computer Core i3 3240 4GB 1TB Windows 7 with 19 5 inch LED monitor or better Cable guide Cable holder CP valve terminals Electrical mounting system Lifting module Measuring module e Linear displacement sensor conductive plastic potentiometer Measuring range 25 mm Resistance 1 k e Comparator Nominal switching distance up to max 400 mm adjustable Power supply 24 V DC Switch outputs 3 PNP normally open contact
18. Frame Rack 35 5 Base deep 28 75 Post Deep 65 High Performance Wire Stripper Electrician Tool Type Wire strippers Application Cable cutting stripping Type of Wire Stranded Handle Length Inches 3 0 Lockable Yes Material Stainless steel Stripping Capacity From 18 to 10 66 High Performance Phone amp Data Crimping Tool Electrician Tool Type Data crimper Application Cuts strips and crimps phone and data wire Type of Wire Solid and stranded Crimping Capacity Phone and data wire Wire Cutting Capacity Inches 1 0 Handle Length Inches 5 0 Lockable Yes Material Metal and plastic Stripping Capacity Phone and data 67 Heavyduty RS232 to USB Adaptor Converter 68 3ft CISCO Smart Serial Cable CAB SS26X26 3 69 Digital Network Cable Tester Page 29 of 60 DESCRIPTION AND SPECIFICATION Power supply 4 x 1 5 V DC AA batteries not included Power consumption up to 16 mA Display 4 x 16 character LCD screen 61 6 x 25 2 mm Designed for STP UTP twin twisted coaxial amp telephone cable Working ambient temperature 10 60 C Tester port tester RJ45 master port M tester LOOPBACK RJ45 port L far end recognizer RJ45 port R Max cable length up to 1350 m Calibration accuracy 3 0 5 m Calibration cable length gt 5 m Cable problems detected open circuit short circuit reverse connection crossover or cross talk interference INTERACTIVE PROJECTOR Projection T
19. Preset value programmable at each digit with up down keys e Reset key for manual resetting e Lock key for locking the preset value Consisting of e Electronic counter with EEPROM for retaining the preset value and the current counter value in case of power failure Page 49 of 60 ITEM DESCRIPTION AND SPECIFICATION i CS _ 26 e 4 place preset value display e Electronic or manual reset e One changeover contact e Supply contact rail e Earth contact rail e Connection for 4 mm safety plug e Attachment via protection against accidental contact with integrated locking strip in the mounting frame for electrical connection and control units or via plug adapter on the slotted assembly board 20 Time relay two fold 1 The element contains a release delay and a pickup delay time relay Both relays are infinitely variable using the rotary knob of the potentiometer e Contact set 2 makes 2 breaks Contact load Maximum 5A e Cut off load Maximum 100 W Delay 0 5 10 s adjustable Consisting of 1 relay for switch on delay 1 relay for switch off delay 2 normally open contacts and 2 normally closed contacts per relay connection for 4 mm safety plug mounting via contact protection with integrated locking strip in the mounting frame for electrical terminal and control units or via plug in adapter on slotted profile plate supply contact rail earth contact rail 21 Systainer Container with components trays 1 Stackable and
20. Status controller The status controller is used as a regulator in pneumatic and hydraulic position control circuits Consisting of Bus bar mass flow rail contact for 4 mm security plugs mounting with protection against accidental contact with a built in lock grid ledge in the fixture for electrical port and control unit or else with plug in adaptors for the profile plate The controller comprises the following e Voltage supply Differential inputs e Comparators po e Final control elements positional control elements speed control elements acceleration lcontrolelements status controller proportional control elements integralcontrol elements differential control elements PID controller e Overall gain Status controller Correcting variable offset e Summing junction e Limited Output Technical Data e Overmodulation indicator 10 gt Ue gt 10 V e Input voltage range 13 13 V e Output voltage limitation 0 10 V 10 10 V e Correcting variable offset 5 3 5 V at 0 10 V 0 7 Vat 10 10V e Position coefficient Kx 10 Speed coefficient Kx 0 100 ms e Acceleration coefficient Kx 0 10s2 e Overall gain P 0 1000 15 Linear drive pneumatic with guide and accessories For proximity sensing with positive locking between piston and carrier and adjustable end position cushioning e Space saving rodless linear drive e Double acting cylinder compressedair for forward and return strokes e P
21. and frequency measurement through a frequency meter Stationary wave SWR measurements Basic principles of Smith chart Impedance and admittance Complex impedance reflection coefficient Stationary wave diagram for different loads Comparison of matched and mismatched loads Study of the Tees and crossguide Measure of wavelength in free space Measure of power emission in free space Study of gain and directivity of a horn antenna dBi Radiation pattern of a horn antenna 7 Reflection of a dielectric plate and metallic plate Dimensions amp Weight e Dimensions 700x700x1100mm approx e Weight 25 Kg approx Required Services e Electrical supply single phase 220V 50Hz E ce Milliampmeter Bright large screen VFD display Digital display 4 1 2 digits Frequency range 5 Hz to 5 MHz AC voltage 50 pV to 300 V ACV test resolution is up to 0 1uV eTwo independent input channels Auto or manual ranging can be selected Standard accessory interface is RS 232 Digital Multitesters e 3 1 2 LCD display with maximum reading of 1999 e Overload protection e Auto power off function e Data hold function e Capacitance measurements e Shock Case e Mechanical protection e 2000uF test function e Diode Testing YES e Audio Testing YES e Continuity Buzzer YES e Auto power Off YES e Data hold YES e Low battery indication YES Technical Specification e Voltage DC 200mV 2V 20
22. capacitance variations with capacitance e A C capacitors in parallel e A C capacitors in series e A C capacitors as voltage dividers e Inductance in an A C circuit Inductive reactance variations with the inductance e Inductors in series in an A C circuit Basic theorems and capacitance and inductance circuits e A C Resistor Capacitor circuits in series e A C Resistor Capacitor circuits in parallel e A C Resistor Inductor circuits in series e Study of Faults in the Circuit e A C Resistor Inductor circuits in parallel RLC Circuits e Resistance Capacitance Filters e Filters inductive resistance Low Pass and High Pass filters Resonance e A C L C Circuits in parallel with low impedance source e Study of Faults in the resonance circuit e A C L C Circuits in parallel with high impedance source e Circuit frequency response and bandwidth Page 7 of 60 D pe SSS SSS e Study of Faults in the resonance circuit The transformer e The transformer e The transformer with load Current measurement in the secondary transformer with charge A TECHNICAL DATA The purpose of Electronics and Electricity Assembly Kits is to provide the students with the necessary lelements for creating their own circuits Each kit contains Assembly and practice manuals 1 manual supplied Set of components and wires necessary for mounting the corresponding practice After the first assembly all the ele
23. circuits it consists on Development board Power supply connector Digital visual display unit Logical source Set of potentiometers Pulse generator and inverters Interrupter Clock 2 Development Module 3 Dimensions 300 x 210 x 45 mm approx Weight 300 gr approx A TECHNICAL DATA The purpose of Electronics and Electricity Assembly Kits is to provide the students with the necessary elements for creating their own circuits 1 DC Circuits kit contains Assembly and practice manuals 1 manual supplied Set of components and wires necessary for mounting the corresponding practice After the first assembly all the elements are recoverable 2 KIT Contents e Manuals Page 5 of 60 ITEM DESCRIPTION AND SPECIFICATION e Set of practice wires switch 2 positions 5 switches 3 positions O red lamp12V button potentiometer 10K button potentiometer 500 ohms resistance 0 bridge 2 resistances 1 5K resistance 100 ohms 5 resistances 10K resistance 12K e 5 resistances 1K e 5 resistances 2 2K e 3 resistances 2 7K e 1 resistance 33 ohms e 2 resistances 330 ohms e 4 resistances 4 7K e 1 resistance 470K e 2 resistances 680 ohms 3 Direct Current Assembly Kit Dimensions 300 x 300 x 200 mm approx e Measurement managing and checking instruments e Electronic instrumentation operation Use of multimeter Study of faults in the Resistance circuit e Ohm
24. conjunction with time delay and flow control valves for compensation of pressure fluctuations as reservoir for sudden pressure drop and for generation of a control system with a delay of the 1st order e Design Brazed tank e Capacity 400 ml e Pressure range 0 1600 kPa 0 16 bar Pressure switch 0 1 bar Pressure switch piezo resistive relative pressure transducer with built in amplifier and temperature compensator on Quick Fixsafety and quick mounting plate for profile platesRotatable 90 detenting e Switching function N O or N C contact PNP e Operating voltage range 15 30 V DC e Idle current max 30 mA e M8x1 connector 4 pin e Cable with M8 socket and 4 mm safety plug e Switching output positive switching PNP e Output current max 100 mA e Reverse polarity e Short circuit overload protection clocking e Nominal pressure range 0 1 bar e Overload pressure short time max 5 bar Vacuum gauge Adjustable red green range Indicating range operating pressure 1 0 bar Quick action mounting system Quick Fix Flow control valve Standard nominal flow rate 85 l min QS 4 connection Vacuum generator type H Operating pressure 1 8 bar Nominal operating pressure 4 5 bar Nominal diameter of laval nozzle 0 45 mm QS 4 connections Max suction rate with respect to atmosphere 6 2 l min Maximum vacuum 88 With silencer plug in Quick action mounting system Quick Fix Vacuum gene
25. e Mechanical set up of a station Sensors Correct application of limit switches PLC Programming and application of a PLC Robotics e Applications of robots e Fundamentals of robotics e Robot terminology e Robot programming Assembly technology e Introduction to and application of automated assembly technologies e Planning an assembly station Commissioning Commissioning of the entire sequence Accessories Components Silent type Compressor Oil lubricated Extremely quiet 45 dB A compressor With pressure regulator and water separator Pressure 800 kPa 8 bar Pmax Performance 50 l min Reservoir capacity 24 Compressed air outlet or KD4 Noise level 45 dB A 1 m Duty cycle max 50 Pressure regulator valve with gauge Design 230 V 50 Hz 1 set desktop computer Core i3 3240 4GB 1TB Windows 7 with 19 5 inch LED monitor or better 1 Trolley e Height incl castors to bottom edge of profile plate 750 mm Width 350 mm Depth 700 mm 2 Workpiece set For cylinder assembly The workpiece set consisting of cylinder components for full assembly body piston spring cover The cylinders can be assembled and dismantled many times e External diameter 40 mm e Height black 22 5 mm e Height red and aluminium 25 mm Page 36 of 60 ITEM DESCRIPTION AND SPECIFICATION 3 Tabletop power supply unit e Input voltage 85 265 V AC 47 63 Hz e Output voltage 24 V DC short circuit proof e Output curren
26. flow control valves e Height 280 mm e Width 60 mm e Length 290 mm Station link receiver Through beam sensor e Nominal switching distance 80 mm e Power supply 24 V DC e Switch output PNP normally open normally closed contact e Connection cable 4 pin Vacuum switch e Mechanical vacuum switch pneumatic electric pressure transduction with adjustable switching point and switching status display LED Mechanical vacuum switch with adjustable switching point and switching status display LED Compressor Silent type 1 unit Oil lubricated Extremely quiet 45 dB A compressor With pressure regulator and water separator Pressure 800 kPa 8 bar Pmax Performance 50 l min Reservoir capacity 24 Compressed air outlet or KD4 Noise level 45 dB A 1 m Duty cycle max 50 Pressure regulator valve with gauge Design 230 V 50 Hz 2 Testing Station PLC Board Control Panel Programming cable Sensors The Testing station employs all basic types of industrial sensors in typical applications Page 31 of 60 ITEM DESCRIPTION AND SPECIFICATION optical capacitive proximity sensors and optical retro reflective sensors supplemented by various cylinder limit switches inductive magnetic Technical data e Operating pressure 600 kPa 6 bar e Power supply 24 V DC e 8 digital inputs e 5 digital outputs Trolley e Height incl castors to bottom edge of profile plate 750 mm e Width 350 mm
27. kPa 0 5 7 bar e Grade of filtration 40 um e Fitting G 1 8 QS 6 for Plastic tubing PUN 6 x 1 15 Manifold 1 Manifold with eight self closing non return valves A common manifold QS 6 for plastic tubing PUN 6 x 1 allows supply of compressed air to the control via eight individual ports QS 4 for plastic tubing PUN 4 x 0 75 e Connector G 1 8 16 Plastic tubing 4 x 0 75 silver 10 m 1 Very flexible and pressure secure PUN 4 x 0 75 Silver e Exterior diameter 4 mm PUN 6x 1 Silver e Exterior diameter 6 mm e Interior diameter 4 mm 17 4 mm Safety laboratory cables 1 10x red 50 mm e 10x blue 50 mm 26x red 300 mm e 11x blue 300 mm 21x red 500 mm e 12x blue 500 mm e 3x red 1000 mm e 3x blue 1000 mm e 1x red 1500 mm e 1x blue 1500 mm Plugs with rigid protective sleeve and axial socket e Conductor cross section 1 mm2 e 1000 V CAT II Rated current 16 A 18 Power supply 1 Input voltage 85 265 V AC 47 63 Hz e Output voltage 24 V DC short circuit proof e Output current max 4 5 A Dimensions 170 x 240 x 92 mm 19 Preset counter electronic 1 Electronic preset counter with terminals for count pulse contact set and reset pulse as well as bus bars for supply power e Contact set 1 changeover contact Contact rating max 5 A e Power consumption 3 W Maximum counting rate 30 Hz Preset value display 4 place red counter reading and yellow preselection illuminated
28. plug on the opposite side The pressure in the distributor can be read off on the pressure gauge 13 Pressure gauge The pressure gauge can be inserted at any point for pressure measurement Effective range and maximum permissible pressure 10 MPa 100 bar e Quality class 1 6 of the full scale value e Operating pressure static 3 4 of full scale value e Operating pressure dynamic 2 3 of full scale value e Cushioning glycerine e Low leakage self sealing couplings 14 Pressure switch electronic The pressure switch can be inserted at any point for pressure measurement and has two switching outputs and an analogue output e Operating voltage 18 35 V DC e Switching outputs 2 x PNP maximum 1 2 A e Effective range and maximum permissible pressure 10 MPa 100 bar e Analogue output 0 10 V e 4 digit digital display can be rotated along 2 axes e Electrical connection M12 5 pin on 4 mm safety plug e Low leakage self sealing couplings 15 Relay three fold The device has three relays with terminals and two buses for power supply e Contact load max 5 A Cut off load max 90 W e Pick up time 10 ms Drop off time 8 ms Consisting of 4 changeover switches electricity supply rail mass flow rail ports for 4 mm safety plugs Mounting with protection against accidental contact with a built in lock grid ledge in the fixture for electrical port and control unit or else with plug in adaptors for the profile plate 16 Signal input electrical_
29. s Law e Ohm s Law verification Power calculation Resistors characteristics and types Resistors measurement Color code Ohmmeter Study of Faults in Resistors circuit Resistors association and the Wheatstone Bridge ee e Voltage and current measurement in a circuit with resistors connected in series Series Parallel configuration study e The Wheatstone Bridge e Study of Fault in Series Resistors circuit e Study of Fault in Parallel Resistors circuit e Study of Fault in Wheatstone Bridge circuit e Kirchoff s laws e Kirchoff s first law e Kirchoff s second law Fault study using Kirchoff s law A TECHNICAL DATA The purpose of Electronics and Electricity Assembly Kits is to provide the students with the necessary elements for creating their own circuits 1 Each kit contains Assembly and practice manuals 1 manual supplied Set of components and wires necessary for mounting the corresponding practice After the first assembly all the elements are recoverable 2 AC Circuit Kit Contents e Manuals e Set of practice wires e 3 coils 100 mH e 4 coils 10 mH e 3 coils 68 mH e 1 ceramic capacitor 220 pF e 1 ceramic capacitor 470 pF e 3 capacitors POLY 100 nF e 1 capacitor POLY 10 nF e 1 capacitor POLY 1 nF e 1 capacitor POLY 220 nF e 2 capacitors POLY 22 nF e 1 capacitor POLY 470 nF e 1 capacitor POLY 47 nF Page 6 of 60 ITEM DESCRIPTION AND SPECIFICATION fe v
30. to do the following practices The bipolar power transistor the power transistor faults in the power transistor he MOSFET transistor the MOSFET transistor faults in the MOSFET transistor The thyristor the thyristor error of the thyristor he UJT transistor and trigger circuits of the thyristor the trigger circuits of the thyristor insulation circuits he TRIAC Study of the TRIAC Practical assembly of the TRIAC Bandwidth 100 Mhz 1GSa s Sampling Rate 2 Channels 7 Widescreen LCD Color Display Equivalent Sampling Rate 50GSa S Memory Depth Single Channel 2 Mpts Double Channels 1 Mpts Rise Time lt 3 5ns nput Impedance 1M 14pF Sec Div range 2 5ns div 50s div Scan 100ms 50s div Display 7 LCD Color 480 234 USB Host Device Support USB Printer and USB Flash Drive PictBridge Function Easyscope Software 40MHz Dual Channel High Sensitivity LMv DIV 5mV div Sensitivity on Both Channels CH1 amp CH2 Independent Channels CH1 Signal Output Unique Digital Filter function and Waveform recorder function Two waveforms in different frequency can be observed via alternative trigger function High speed sweep Algebraic Addition and Subtraction X Y Operation 0 2us div to 0 5s div Time Base Uncal up to 20ns Page 13 of 60 27 8 x 10 cm Display Internal Graticule ITV signal synchronous function TV Triggering Frame V amp Line H Line Trigger Rated Output Po
31. 20 A max open circuit voltage 68 VDC dimensions 980x410x650 mm weight 70kg MIG welding machine 280A Primary Supply 3 ph 415 V Max input current 24A Output rating 280A 28V Duty cycle 100 190A 24V Output control Tapping Open circuit voltage 18 39V Welding range at 50 210A 40 280A Filler wire size range 0 6 1 2mm Wire feeding speed 1 17m min Time Spot Stitch 0 5 sec Degree of protection IPS21 Insulation class H 180degree C Weight w o cable and plug 125 kgs Dimension LxWxH 950mmx510x838mm Contents 1 MIG Torch assembly 5 pcs MIG Nozzle 10 pcs Contact Tip 1 can MIG Nozzle cleaner 1 spool MIG wire 0 8mm TIG Welding Machine 300A with Complete Accessories Input 26 KVA 50 60hz DC output current 5 300A AC output current 20 300V DC output voltage 16 20V TIG 20 32 Manual AC output voltage 16 22V TIG 20 35V Manual Duty cycle 100 200 A may vary accdg To room temp Weight 175 kgs High frequency TIG torch assembly automatic darkening welding machine mask argon gas with cylinder argon regulator 10 pcs tungsten 2 4mm 5 pcs ceramic cup 10 pcs collet 10 pcs collet holder 5 kls filler rod 2 4mm lOxygen Acetylene Welding Cutting Outfit oxygen cylinder with oxygen gas acetylene cylinder with acy gas twin hose 10 ft 3m 1 set oxy acy regulator 1 set flashback arrester 7 Content Heavy Duty cutting disc 14
32. 75mvV Channel 1 I8MHz 10MHz 30mvV Channel 1 10MHz 100MHz 30mV Channel 1 F1000C 100MHz 1000MHz 30mV Channel 2 F2700C 100MHz 2400MHz 30mV Channel 2 2 4Hz 2 7Hz 30mV Channel 2 nput Impedance 1M Q at Channel 1 500 at Channel 2 Max Input Voltage 250Vrms Channel 1 5Vrms Channel 2 Max Aging Rate 5ppm year Power Input AC 220 10 50 60Hz Power Consumption approx 5W Dimension 230 W x 210 H x 76 D mm 3 1 2 LCD display with maximum reading of 1999 Overload protection Auto power off function Data hold function Capacitance measurements Shock Case Mechanical protection 2000uF test function Diode Testing YES Audio Testing YES Continuity Buzzer YES Auto power Off YES Data hold YES Low battery indication YES Technical Specification Voltage DC 200mV 2V 20V 200V 1000V Voltage AC 200mV 2V 20V 200V 700V Direct Current 2mA 20 mA 200 mA 10A Alternating Current 2mA 20 mA 200 mA 10A Resistance 2000 2k0 20kQ 200kQ 2MQ 20MQ 200MQ Easy to assemble Break proof body cover Solded test leads providing better safety Portable analog multitester Technical Specification DCV 0 3 3 12 30 120 300 600V 20k Q V ACV 12 30 120 300 600V 9k 9 V DCA 60p 3m 30m 0 3A Resistance 20 200 20k Battery check 1 5 Bandwidth 50 or 60Hz sine wave Battery UM 3 1 5V x 2 Fuse 5 2x20mm 250V 0 5A Size Mass H159 5 x W129 x D41 5mm 320g Standard Accessories included Ins
33. Analogue I O terminal strip 8D1 80 and 4AI 2A0 Syslink Plug Connection of Digital and Analogue 1 0 to Controllers such as PC or PLC Signal conversion with parameterisable measured value transducers includes parameterization software and programming cable Controller Programmable Logic Controller 16 Digital Inputs 16 Digital Outputs 4 Analogue Inputs 4 20 mA 0 10V RTD 2 Analogue Outputs 4 20 mA and 0 10V 24 Vdc Power Ethernet Interface for Fieldbus HMI and Programming Connections CANOpen fieldbus interface 2 1 1 P B Digital I O Syslink Cable Analogue I O Syslink Cable Ethernet Cable Crossed LC Development Software uilt in Software Simulator or Virtual PLC with Runtime and Graphics Monitoring Visualization Software Controller in a PC Measuring and Control with Real Time Graph and Measurement Data c c H harateristic Curves of Sensors and Actuators losed Loop Control of Level Flow Pressure and Temperature using PID Continuous Control or ON OFF ITwo Point Control Manual Open Loop Control of Level Flow Pressure and Temperature Filtering of Measurement Signals from Sensors Offset and Re ranging of Measurement Signals from Sensors Simulation with P amp ID Model of Process Control without the Actual Hardware Testing and Commissioning of Process Control Hardware Fault Simulation Module Four 4 Fault Simulation for Level Control Loop Six 6 Fault Simulation for Flow Control Loop ive 5
34. CPX terminal can be connected 1 set Desktop computer Core i3 3240 4GB 1TB Windows 7 with 19 5 inch LED monitor or better Aluminium profile plate 350 x 700 mm e Grid Dimension 50mm Cable holder Conveyor module 350 with DC motor complete with DC motor e For the transport of workpieces of 40 mm diameter or for the transport of workpiece carriers e Transport distance 350 mm e DC motor 24 V DC 1 5 A CP valve terminals Diffuse sensor Electrical mounting system Inductive sensor On off valve with filter regulating valve e quick push in connections and quick couplings mounted on a swivel support Profile plate connector Retro reflective sensor e complete with brackets for mounting on a profile or profile plate Operating distance 10 700 mm e Power supply 24 V DC e Switch output PNP normally open normally closed contact e Connection cable 4 pin Set of guide rails Sorting e Operating distance 10 700 mm Page 35 of 60 ITEM DESCRIPTION AND SPECIFICATION i CS e Power supply 24 V DC e Switch output PNP normally open normally closed contact e Connection cable 4 pin Slide module Sorting gate module pneumatic Starting current limiter e can be mounted on a DIN rail Electrical connection is by means of screw terminals e Control voltage 24 V DC e Current 1A e Current limitation at switching torque to 2 A Stopper module e Complete with double acting short stroke cylinder senso
35. IFICATIONS A TECHNICAL DATA The purpose of Electronics and Electricity Assembly Kits is to provide the students with the necessary elements for creating their own circuits it contents the following e Manuals e Set of practice wires e 2 coils 10mH e 1 coil 1mH 5MM e 11 C NE555 e 11 C TL072 3 bypass ceramic capacitors 100 nF Page 9 of 60 e 4 capacitors POLY 1pF e 8 capacitors POLY 100 nF e 5 capacitors POLY 10 nF e 2 capacitors POLY 4 7 nF e 2 diodes e 2 button potentiometers 1K e 1 button potentiometer 500K e 1 button potentiometer 5K e 2 resistances 0 e 2 resistances 100K e 4 resistances 10K e 2 resistances 15K e 2 resistances 1K e 1 resistance 1M e 6 resistances 2 2K e 1 resistance 220K e 2 resistances 22K e 2 resistances 470 ohms e 3 transistors approx Experiment Possibilities Oscillators RC and LC Nets RC net oscillator LC net oscillator Faults study with RC and LC Net oscillators Wien bridge oscillator Wien Bridge Fault study in the Wien bridge oscillator Colpitts oscillator Hartley oscillator Colpitts oscillator Hartley oscillator Faults study with the Colpitts oscillator TENDER SPECIFICATIONS A TECHNICAL DATA Each kit contains Assembly and practice manuals 1 manual supplied Set of components and wires necessary for mounting the corresponding practice After the first assembly all the elements are
36. Section VII Technical Specificatic Technical Specificatior Notes for Preparing the Technical Specifications A set of precise and clear specifications is a prerequisite for Bidders to respond realistically and competitively to the requirements of the Procuring Entity without qualifying their bids In the context of Competitive Bidding the specifications e g production delivery schedule manpower requirements and after sales service parts must be prepared to permit the widest possible competition and at the same time present a clear statement of the required standards of workmanship materials and performance of the goods and services to be procured Only if this is done will the objectives of transparency equity efficiency fairness and economy in procurement be realized responsiveness of bids be ensured and the subsequent task of bid evaluation and post qualification facilitated The specifications should require that all items materials and accessories to be included or incorporated in the goods be new unused and of the most recent or current models and that they include or incorporate all recent improvements in design and materials unless otherwise provided in the Contract Samples of specifications from previous similar procurements are useful in this respect The use of metric units is encouraged Depending on the complexity of the goods and the repetitiveness of the type of procurement it may be advantageous to standardize the Gene
37. The device contains an illuminated pushbutton switch control switch and three illuminated pushbuttons momentary contact switches with terminals and two buses for power supply e Contact set 1 makes 1 breaks e Contact load Maximum 2 A e Power consumption Miniature bulb 0 48 W Consisting of 3 illuminated push buttons 1 illuminated pressure switch each with a mini bulb bus bar mass flow rail 1 N O contacts and 1 NC contacts for 4 mm security plugs Mounting with protection against accidental contact with a built in lock grid ledge in the fixture for electrical port and control unit or else with plug in adaptors for the profile plate 17 Limit switch electrical left actuated The micro switch is actuated mechanically when the roller lever is pressed for example by the trip cam of a cylinder The micro switch can be wired as a N O contact N C contact or a changeover switch using the 4 mm safety sockets integrated in the quick action mounting system Quick Fix Possible contact load maximum 5 A e Limit switch electrical right actuated The micro switch is actuated mechanically when the roller lever is pressed for example by the trip cam of a cylinder The micro switch can be wired as a N O contact N C contact or a changeover switch using the 4 mm safety sockets integrated in the quick action mounting system Possible contact load maximum 5 A 18 Proximity sensor electronic Magneto resistive proximity sensor
38. UNIVERSAL CISCO 2911 AC Power Supply CISCO Config Pro Express on Router Flash 512MB DRAM for CISCO 2901 2921 ISR Default 256MB Computer Flash for CISCO 1900 2900 3900 ISR P Base License for CICSO_ 2901 2951 58 SMARTNET 8X5XNBD for CISCO 2911 Routers 59 2 Port Serial WAN Interface Card HWIC 2T 60 CISCO CATALYST 2960 24PC L Device Type Switch 24 ports Managed Enclosure Type Rack mountable 1U Interfaces Fast Ethernet Ports 24 x 10 100 PoE 2 x combo Gigabit SFP Power Over Ethernet PoE PoE Performance Switching capacity 32 Gbps Forwarding performance 64 byte packet size 6 5 Mpps MAC Address Table Size 8K entries Remote Management Protocol SNMP 1 SNMP 2 RMON 1 RMON 2 RMON 3 RMON 9 Telnet SNMP 3 SNMP 2c HTTP HTTPS TFTP SSH SMARTNET 8X5XNBD Catalyst 2960 24PC L 62 Linksys EA Series 2700 3500 4500 or equivalent Wireless N Router b g n 63 Branded All in one Computer Units TOPERATING SYSTEM Windows DISPLAY 23 0 58 4cm 16 9 Full HD 1920x1080 LED backlight 178 wide viewing angle Touch Screen Multi Touch 10 Fingers Touch PROCESSOR Intel Core i5 3330 6M Cache 3 0 GHz Turbo Boost up to 3 2GHz CHIPSET Intel B75 MEMORY 8 GB DDR3 at 1600MHz STORAGE 1TB SATA Hard Drive 7200RPM WIRELESS DATA NETWORK 802 11 b g n or 802 11 b g n WiDi Optional LAN 10 100 1000 Mbps CAMERA 2 MP CARD READER 3 in 1 SD SDHC MMC 64 45U 2 Welded 4 Por Steel
39. V 200V 1000V e Voltage AC 200mV 2V 20V 200V 700V e Direct Current 2mA 20 mA 200 mA 10A 48 e Alternating Current 2mA 20 mA 200 mA 10A e Resistance 2000 2k0 20k0 200k0 2M0 20MQ 200MQ LABORATORY TABLE 8pcs 2440 x 800mm 30mm laminated board table top with PVC edging provided with grommet caps for computer monitor wire access Page 21 of 60 ITEM DESCRIPTION AND SPECIFICATION Powder coated steel casing for table top electrical outlets with removable front plate powder coat finish Includes wiring provisions for eight 2 gang universal outlet and LAN provision for two 2 computers Plastic keyboard tray Powder coated Tubular metal framing with perforated plate cover for table legs support and adjustable metal glides 18mm laminated board with PVC Edgeband CPU shelving MULTIMEDIA PROJECTOR 1 USB 3LCD Projector 2800 or better Lumens White and Colour Light Output Computer Cable USB A USB B Cables Remote Control Soft Carry Case amp Manual INTERACTIVE WHITEBOARD 1 78 diagonal surface 4 pens 1wand wall mount USB Interface computer connection Workspace software Infrared Technology pen amp finger touch with Windows Mac or Linux Multi touch with Windows 7 aspect ratio 4 3 8000x8000 resolution Android amp IOS tablet compatible ISTORAGE CABINET 1 1 20m x 1 90m Sliding Glass doors on powder coated aluminum frame with lock 18mm laminated boards with PVC edging 3 3 Electrical Machines In
40. V DC e N O contact PNP starting function e Quick Fix quick connector system e Sensing distance of O 4 mm Indicator unit and distributor electrical The device contains an acoustic indicator and four lamps with terminals and three buses for power supply Through contact socket pairs per lamp allow the element to also be used as a distributor e Power consumption acoustic indicator 0 04 W e Power consumption indicator lamps 1 2 W Frequency acoustic indicator 420 Hz Consisting of Bus bar mass flow rail contact for 4 mm security plugs mounting with protection against accidental contact with a built in lock grid ledge in the fixture for electrical port and control unit or else with plug in adaptors for the profile plate Slide unit Set of test objects Set of test objects for determining the response characteristics of sensors consisting of sample materials in different designs and material strength e Magnets e Transparent and coloured plastics Various metals Magnets Rubber Cardboard odak grey card Wood Size 50 x 50 mm Tabletop power supply unit nput voltage 85 265 V AC 47 63 Hz Output voltage 24 V DC short circuit proof Output current max 4 5A Dimensions 170 x 240 x 92 mm Workbook Fifteen projects based on industrial examples each including problem descriptions parameters and project tasks deal in detail with the specific subject of sensors for object detection The main topics are c
41. acteristics of Zener diodes perational characteristics of single phase transformers in idle running and short circuit modes perational characteristics of single phase transformers with active loads perational characteristics of single phase rectifiers without a filter perational characteristics of single phase rectifiers with a filter haracteristics of three phase networks and transformers star delta connection Characteristics of three phase networks and transformers star star connection Operational characteristics of single phase controlled rectifiers with active load Operational characteristics of three phase controlled rectifiers with active load Desktop Computer a Windows 8 mouse amp keyboard with UPS Laboratory Tables Teacher amp Student Chairs Hanging storage Cabinet Interactive Whiteboard amp Multimedia projector Laboratory Table 4 pcs 2440 x 800mm 30mm laminated board table top with PVC edging Page 17 of 60 3 2 C DESCRIPTION AND SPECIFICATION 18mm laminated board with PVC edging electrical outlets with removable front plate Includes wiring provisions for four 2 gang universal outlet Powder coated Tubular steel metal framing Detachable with joining pins iTeacher s table 1 1000x950x780mm Table 18mm Laminated Board with PVC edging Teacher s chair 1 Executive type Non Folded Finished Materials PU Steel PP Back PU or better Seat Cutting sponge wi
42. aining program provides beginners with an ideal introduction to lEC compliant programming e In addition to trainees pupils and students it also appeals to skilled workers technicians and engineers who have previously only programmed in IL LDR or FCH The higher IEC compliant languages provide a range of benefits to be discovered and used Accessories e I O data cable with connectors IEEE 488 at both ends 2 5 m e Universal connection unit digital Programming cable e Programming software Workbook Instrumentation and Process Control Compact Workstation Actuators Centrifugal Pump 0 10 V Control Voltage Proportional Solenoid Process Valve 0 10V Control Voltage Process Ball Valve with On Off Pneumatic Quarter Turn Actuator Heater 1 KW Po ee The Compact Workstation Energy is equipped with current and power meters and includes the measuring and training monitoring software Energy Power supply unit Input voltage 85 265 V AC 47 63 Hz Output voltage 24 V DC short circuit proof Output current max 4 5A Monitoring Visualization software Operation open and closed loop control with the Easy Port communication module Interfacing unit between the computer to Process Control or PLC to Hardware or software to software Visualization Control technology operations and continuous and discontinuous controllers are presented Subsequent analyses bring a valuable basic realization which can be transferred to t
43. and quick mounting system for profile plates and cables with safety plug e 360 rotatable detenting every 15 e Size Q30 e Operating voltage 10 30 V DC e Type of light red e Polarised e Range up to 2000 mm e Adjustable by potentiometer e Connection via the 4 mm safety connectors integrated in the Quick Fix quick mounting system Page 45 of 60 ITEM DESCRIPTION AND SPECIFICATION e Starting function N O contact PNP Reflector triple mirror 20 mm Reflector on the Quick Fix secure and quick action mounting system for profile plates e 360 rotatable detenting every 15 e principle triple mirror e diameter 20 mm Diffuse sensor with background suppression Diffuse sensor with background suppression optical proximity switch on Quick Fix safety and quick mounting system for profile plates and cables with safety plug e 360 rotatable detenting every 15 e Size Q20 e Operating voltage 10 30 V DC e Type of light red e Range up to 100 mm e Adjustable using teach In e Connection via the 4 mm safety connectors integrated in the Quick Fix quick mounting system e Starting function N O and N C contact PNP Proximity sensor capacitive M12 Proximity sensor with protection against polarity reversal overload and short circuit e M12 design e 360 rotatable detenting every 15 e Connection via the 4 mm safety connectors integrated in the Quick Fix quick connector system e Power supply 10 36
44. annels USA 1 11 its FPGA type Xilinx Z 7010 International 1 13 TX power 10 dBm max 10 mW Outdoor range Up to 150 m line of sight Antenna directivity Omnidirectional Security WPA WPA2 WPA2 Enterprise USB host port USB 2 0 Hi 5 peed USB device port USB 2 0 Hi Speed Page 58 of 60 ITEM DESCRIPTION AND SPECIFICATION es Analog Input Aggregate sample rate 500 kS s Resolution 12 bits Overvoltage protection 16 V MXP connectors Configuration Four single ended channels per connector Input impedance gt 500 kQ acquiring at 500 kS s 1 MQ powered on and idle 4 7 kQ powered off Recommended source impedance 3 KO or less Nominal range 0 V to 5 V Absolute accuracy 50 mV Bandwidth gt 300 kHz MSP connector Configuration Two differential channels Input impedance Up to 100 nA leakage powered on 4 7 kQ powered off Nominal range 10 V Working voltage signal common mode 10 V of AGND Absolute accuracy 200 mV Bandwidth 20 kHz minimum gt 50 kHz typical Audio input Configuration One stereo input consisting of two AC coupled single ended channels Input impedance 10 KQ at DC Nominal range 2 5 V Bandwidth 2 Hz to gt 20 kHz Analog Output al AO channels on MXP connectors 345 kS s Po All AO channels on MSP connector and audio output channels 345 kS s Resolution 12 bits Overload protection 16 V Startup voltage 0 V after FPGA initialization MXP connectors Configuration Two si
45. apted to suit your current signals and systems courses and text books Introduction to the SIGEx board Special signals characteristics and applications Systems Linear and non linear Unraveling convolution Integration convolution correlation amp matched filters Exploring complex numbers and exponentials Build a Fourier series analyzer Spectrum analysis of various signals Time domain analysis of RC networks Lab 10 Poles and zeros in Laplace domain Lab 11 Sampling and Aliasing Lab 12 Getting started with analog to digital conversion Lab 13 Discrete time filters FIR Lab 14 Poles and zeros in the z plane IIR forms ee Lab 15 Discrete time filters practical applications App A SIGEx Lab to Textbook chapter table SIGEx 1 Compatible with ELVIS platform Board accessories kit includes 20 x stackable patch cords User Manual Digital and Analog Basic Telecommunications Experiments Manual Volume 1 DATEX SFP CD ROM Telecommunication Topics Basic Analog Communications AM FM DSB SSB PM PAM TDM PWM Superheterodyne Speech in Comms PLL QAM SNR Concepts and more Digital Communications PCM PCM TDM ASK BPSK FSK GFSK Eye Patterns DPSK QPSK Spread Spectrum Line Coding 5 Noise Generation SNR Concepts and more Components standard PB 501 breadboard 8 Data Switches The data switch circuits provides eight DATA OUTPUT pins D1 to D8 whose output level is adjusted
46. ards that ensure substantial equivalence to the standards and codes specified will be acceptable Reference to brand name and catalogue number should be avoided as far as possible where unavoidable they should always be followed by the words or at least equivalent References to brand names cannot be used when the Funding Source is the GOP Where appropriate drawings including site plans as required may be furnished by the Procuring Entity with the Bidding Documents Similarly the Supplier may be requested to provide drawings or samples either with its Bid or for prior review by the Procuring Entity during contract execution Bidders are also required as part of the technical specifications to complete their statement of compliance demonstrating how the items comply with the specification Technical Specifications Item Description Statement of Compliance Bidders must state here either Comply or Not Comply against each of the individual parameters of each Specification stating the corresponding performance parameter of the equipment offered Statements of Comply or Not Comply must be supported by evidence in a Bidders Bid and cross referenced to that evidence Evidence shall be in the form of manufacturers un amended sales literature unconditional statements of specification and compliance issued by the Page 1 of 60 manufacturer samples independent test data etc as appropriate A stat
47. ariable capacitor 5 5 65 pF 9 switches 2 positions 8 switches 3 positions resistance 10 ohms 3 resistances 100 ohms resistance 100K 9 resistances 10K 3 resistances 1K 7 resistances 2 2K resistance 270 ohms resistance 3 3K e 4 resistances 330 ohms e 5 resistance 4 7K e 3 resistances 470 ohms e 4 resistances 680 ohms transformer 2 8 VA red lamp 12V direct current button potentiometer 10K button potentiometer 500 ohms resistance 0 bridge 2 resistances 1 5K resistance 12K e 3 resistances 2 7K e 1 resistance 33 ohms 3 Dimensions 300 x 300 x 200 mm approx This kit is designed to be able to do the following practices Alternating signal characteristics instruments e Waveforms study in A C e Introduction of anomalies in the Wave form circuit e Study of Faults in the Wave form circuit e Relation between peak values and RMS for sinusoidal waves e Resistance in a sinusoidal alternating current e Measurements using the oscilloscope e Voltage and current phase angles for resistors in sinusoidal alternating current Sinusoidal A C resistors in series e Sinusoidal A C resistors in parallel Behaviour of A C capacitors and inductors e Capacitance with square waveform and sinusoidal input current e Inductance with square waveform and a sinusoidal input voltage e Reactive reactance Xc variations with the frequency Study of faults in capacitors e Reactive
48. bar e Maximum permissible pressure 12 MPa 120 bar e Low leakage self sealing quick coupling sockets e 4 2 way solenoid valve spring return e Actuation switching solenoid e Operating pressure 6 MPa 60 bar e Maximum permissible pressure 12 MPa 120 bar e Valve port pattern hydraulic ISO DIN 4401 size 02 e Low leakage self sealing coupling nipples e 24 V DC power e 6 5 W output e Electrical connection 4 mm safety socket e Quick action mounting system Quick Fix 5 e 4 3 way solenoid valve closed mid position e Actuation switching solenoid e Operating pressure 6 MPa 60 bar e Maximum permissible pressure 12 MPa 120 bar e Valve port pattern hydraulic ISO DIN 4401 size 02 e Low leakage self sealing coupling nipples e 24 V DC power e 6 5 W output e Electrical connection 4 mm safety socket e Quick action mounting system Quick Fix 6 4 2 way double solenoid valve detenting e Actuation switching solenoid e Operating pressure 6 MPa 60 bar e Maximum permissible pressure 12 MPa 120 bar e Valve port pattern hydraulic ISO DIN 4401 size 02 e Low leakage self sealing coupling nipples e 24 V DC power e 6 5 W output e Electrical connection 4 mm safety socket e Quick action mounting system Quick Fix 7 Shut off valve The valve can be closed by turning the lever This presses a ball onto the seal on the non pressurized side sealing off the flow without any leakage e Actuation manual e Operati
49. contact load maximum 5 A 5 Proximity sensor optical M12 1 Proximity sensor with protection against polarity reversal overload and short circuit e M12 design e 360 rotatable detenting every 15 e Connection via the 4 mm safety connectors integrated in the Quick Fix quick connector system e Power supply 10 30 V DC e N O contact PNP starting function e Quick Fix quick connector system e Adjustable sensing distance of 70 300 mm with LED 6 Electronic proximity sensor with cylinder attachment 2 Magneto resistive proximity sensor magnetically operated e Connection via 4 mm safety sockets e Switching output N O contact PNP with switching status indication e Overload and short circuit proof with reverse polarity protection e Operating voltage 5 30 V DC e Output current max 100 mA Switching time on off max 1 ms e Mounting system for cylinder diameter 20 mm 2x T slot for simultaneous mounting of one pneumatic and one electronic proximity sensor 7 _2 x 3 2 way solenoid valve with LED normally closed 1 Pilot actuated single solenoid piston spool valve with pneumatic spring return non detenting and detenting manual override and LED e Electrical connection via integrated 4 mm safety sockets e 24 V DC power supply e Switching time on off 6 16 ms e Pneumatic connection via QS 4 push in fitting e Operating pressure 150 800 kPa 1 5 8 bar e Quick Fix safety and quick act
50. cs Installation of tubing for pneumatic components Pneumatic grippers Pneumatic linear drives Electrical Correct wiring of electrical components Sensors Correct application of limit switches PLC Programming and application of a PLC Control of a handling device Commissioning Commissioning of the entire sequence Optimisation of cycle time Page 39 of 60 TEM DESCRIPTION AND SPECIFICATION Safety in the event of loss of pneumatic or electrical power Accessories Components Desktop Computer 1 unit Core i3 3240 4GB 1TB Windows 7 with 19 5 inch LED monitor or better 1 Trolley The trolley makes an MPS station a compact and mobile unit The station is easy to mount on the trolley An EMERGENCY STOP board can also be fitted Appropriate through holes in the side and rear panels enable orderly routing of cables The front side is equipped with mountings for the control panel The trolley is supplied complete with castors Height incl castors to bottom edge of profile plate 750 mm Width 350 mm Depth 700 mm 2 Control console allows simpler operation of the MPS station SysLink or AS interface various interfaces ensure versatility of use Fully assembled with operating panel communication panels spare panel and mounting frame with SysLink connector Membrane keyboard Start pushbutton with LED Stop pushbutton Reset pushbutton with LED 2 flexibly assignable control lamps 4 mm safety sockets with LED status di
51. ctric 1 Contact set 1 makes 1 breaks Contact load Maximum 2 A Power consumption Miniature bulb 0 48 W Consisting of 3 illuminated push buttons illuminated pressure switch each with a mini bulb bus bar mass flow rail 1 N O contacts and 1 NC contacts for 4 mm security plugs Mounting with protection against accidental contact with a built in lock grid ledge in the fixture for electrical port and control unit or else with plug in adaptors for the profile plate 2 Relay Three fold 2 Contact set 1 makes 1 breaks Contact load Maximum 2 A Power consumption Miniature bulb 0 48 W Consisting of 3 illuminated push buttons 1 illuminated pressure switch each with a mini bulb bus bar mass flow rail 1 N O contacts and 1 NC contacts for 4 mm security plugs Mounting with protection against accidental contact with a built in lock grid ledge in the fixture for electrical port and control unit or else with plug in adaptors for the profile plate 3 Limit switch electrical left actuated 1 The micro switch can be wired as a N O contact N C contact or a changeover switch using the 4 mm safety sockets integrated in the quick action mounting system Quick Fix Possible contact load maximum 5 A 4 Limit switch electrical right actuated 1 The micro switch can be wired as a N O contact N C contact or a changeover switch using the 4 mm safety sockets integrated in the quick action mounting system Quick Fix Possible
52. dheld for CPX terminal can be connected All FEDs can be connected via Ethernet Visualisation OPC server for connection to any SCADA packages 4 Aluminium profile plate 350 x 700 mm Grid Dimension 50mm 5 Cable holder 6 CP valve terminals 7 Electrical mounting system 8 On off valve with filter regulating valve Filter regulator with pressure gauge on off valve quick push in connections and quick couplings mounted on a swivel support 9 Piston pallet Pallet for the storage of 4 pistons Cylinder for assembly workpiece set 10 mm diameter and 16 mm diameter from workpiece set For cylinder assembly Pallet size 2 x 4 locations Height 20 mm Width 90 mm Length 140 mm 0 Profile plate connector 1 Separating module springs Height 260 mm Width 70 mm Length 220 mm The module separates springs Cylinder for assembly workpiece set from a gravity fed magazine and makes them available to the assembly process A double acting cylinder moves the springs to the transfer point A micro switch detects whether there is a spring in the transfer point 2 Slide module The slide comes complete with a retainer for mounting on a profile plate 3 Stacking magazine module end caps Height 190 mm Width 60 mm Length 290 mm 4 Station link receiver Through beam sensor Nominal switching distance 80 mm Power supply 24 V DC Switch output PNP normally open normally closed contact Connec
53. echnology RGB liquid crystal shutter projection system 3LCD LCD Size 0 59 with MLA D8 Native Resolution WXGA Projection Lens Type No Optical Zoom Focus Manual F Number 1 80 Focal Length 3 71mm Zoom Ratio 1 1 35 Digital Zoom Throw Ratio 0 27 0 37 Wide Tele Lamp Type EB 1400Wi 190W UHE EB 1410Wi 215W UHE Life Normal Eco 3 500 hours 5 000 hours Screen Size Projected Distance 74 3 screen 0 438m 60 to 100 0 348 to 0 597m Network Wired LAN RJ45 x 1 10 100Mbps Wireless Yes ELPAPO7 BASIC SPECIFICATIONS Technology Infrared Input Devices Digital Pen Easy Interactive Pen 1 and 2 Connection to PC USB Network Calibration Auto Manual 25points Functions Hover Right click Auto Adjust Pen Area 71 Stacking chairs for students 45 pcs e Chair seat amp back high quality polypropylene e Chair frame Round steel tube heavy duty high quality electro static powder coated e Stacks 10 high from the floor Color Navy blue dark blue 72 Computer Table High pressure laminate top that is 1 1 4 thick with radius corners and vinyl edge banding Scratch resistant environmentally friendly powder coat paint finish on welded leg assemblies and modesty panel Modesty panel features center grommet for wire pass through Adjustable leveling glides 24 D table with 30 W 26 fixed height 73 Display Cabinet Made with tempered glass pan
54. ection via integrated 4 mm safety sockets e 24 V DC power supply Switching time on off changeover 10 30 16 ms e Pneumatic connection via QS 4 push in fitting e Operating pressure 300 800 kPa 3 8 bar e Quick Fix safety and quick action mounting system for slotted profile plates e 5 3 way proportional valve The integrated electronic control of the slide path allows favorable static and dynamic characteristics as reflected by low hysteresis lt 0 3 short switching time typically 5 ms and higher upper critical frequency approx 100 Hz For this reason the valve is particularly suitable as an actuator for position control of a pneumatic cylinder particularly in conjunction with a higher level position controller 5 3 way proportional valve mid position closed actuated on both sides spring centered manual override mounting system e Medium Compressed air microfiltered unlubricated e Pressure range 600 1000 kPa 6 10 bar e Flow rate at nominal pressure Maximum 700 I min e Power consumption 2 20W e Analog setpoint voltage 0 10 V DC e Nominal value at pneumatic mid position 5 V DC e Duty cycle in accordance with VDE 0580 100 12 Air pressure reservoir 0 41 Air pressure reservoir for generating static pressure with the aid of a one way flow control valve for the generation of long time delays in conjunction with time delay and flow control valves for compensation of pressure fluctuations a
55. els 4 tempered glass shelves Twin lockable tempered glass doors Chrome plated fittings 4 Wheels amp feet Twin cupboard doors at bottom Frameless design Black Laminate finish Dimensions 1016mm w x 457mm d x 1850mm h LOT 11 P 38 061 839 00 Including Civil Works P 691 839 00 11 1 Advanced Mechatronics Laboratory 74 Modular Production System Mechatronics Station with Mechatonics Assistant 1 Distribution Station Programming cable Low noise compressor Semi rotary actuators e swivel arm can be set to various angles between 90 and 270 e end positions are sensed by means of micro switches e double acting linear cylinder pushes workpieces out of the stacking magazine Special grippers Suction gripper Page 30 of 60 ITEM DESCRIPTION AND SPECIFICATION e Operating pressure 600 kPa 6 bar e Power supply 24 V DC e 7 digital inputs e 5 digital outputs O e Height incl castors to bottom edge of profile plate 750 mm e Width 350 mm Depth 700 mm Control console e Fully assembled with operating panel communication panels spare panel and mounting frame with SysLink connector e Membrane keyboard Start pushbutton with LED Stop pushbutton Reset pushbutton with LED 2 flexibly assignable control lamps 4 mm safety sockets with LED status display for simple I O connection Syslink and Sub D sockets for connection to PLC of choice are available on the rear panel e full
56. em for slotted profile plates 3 2 x 3 2 way solenoid valve with LED normally closed Po 600 and the MPS punching station e Mounting on Learnline with universal bracket e Mounting on Learntop S direct e Pump design external gear motor with pressure relief valve adjustable from 0 6 MPa 0 60 bar e Operating pressure 6 MPa 60 bar e Motor AC single phase with overload protection start capacitor and ON OFF switch e Tank 5 volume sight glass temperature display drain screw e Air filter and return filter Low leakage self sealing coupling nipples for P and T Plug socket for unpressurised return Connecting flange for measuring container return Dimensions 580 x 300 x 180 mm W x D x H Weight 19 kg Nominal voltage 230 V AC Rated output 0 65 kw Frequency 50 to 60 Hz Delivery rate rated speed 2 2 2 7 I min at 1320 1680 m 1 Protective cover for weight 9 kg Tabletop power supply unit Power supply unit for mounting frame Hydraulics Simulation software license Electrohydraulics WBT a Pilot actuated single solenoid piston spool valve with pneumatic spring return non detenting and detenting manual override and LED e Electrical connection via integrated 4 mm safety sockets Page 53 of 60 ITEM DESCRIPTION AND SPECIFICATION o CSCS 8 PID controller PID controller for pneumatic and hydraulic control circuits Consisting of Bus bar mass flow rail contact for 4 mm security
57. embly Pallet size 2 x 4 locations Height 20 mm Width 90 mm Length 140 mm 5 Gripper pneumatic 6 Profile plate connector Length 45 mm Mounting method Bolt with rotating head and M6 hammer head nut 7 Separating module springs Height 260 mm Width 70 mm Length 220 mm 8 Slide module Height 260 mm Width 70 mm Length 220 mm 9 Stacking magazine module end caps Height 190 mm Width 60 mm Length 290 mm 20 Station link receiver 21 Through beam sensor Nominal switching distance 80 mm Power supply 24 V DC l Switch output PNP normally open normally closed contact Connection cable 4 pin 22 Holder module The Holder module comes complete with a holder for mounting on a profile plate Application As horizontal workpiece holder at the end of an inclined slide Standard height 40 60 mm adjustable 23 e Retaining module e The retaining module has two setdown positions The upper setdown position allows workpieces to be set down independent of their orientation The lower setdown position has a locking pin Workpieces cylinder bodies have to be inserted in the correct orientation The holding pin ensures that the cylinder body does not turn during assembly of the cap e Inclusive Teachdorn for robot Page 37 of 60 ITEM DESCRIPTION AND SPECIFICATION 24 Terminals and series resistors 25 Robot Teachbox B Assembly station The assembly station works in c
58. ement that is not supported by evidence or is subsequently found to be contradicted by the evidence presented will render the Bid under evaluation liable for rejection A statement either in the Bidders statement of compliance or the supporting evidence that is found to be false either during Bid evaluation post qualification or the execution of the Contract may be regarded as fraudulent and render the Bidder or supplier liable for prosecution subject to the Includes AUGMENTED WELDING SIMULATOR Supported welding processes Manual arc welding MIG MAG TIG SMAW GMAW GTAW Supported joints Standard version T Joint Lap Joint V Butt Joint Pipe V Butt Joint Pipe T Joint Welding positions PA PC PG PE PH PJ H LO45 J LO45 PB PD 1F 2F 3F 4F 1G 2G 3G 4G 5G 6G Workpieces positions plain vertical flat overhead Voltage selection 10V 30V MIG MAG GMAW FCAW 12V 32V Intensity AmpearageO selection electrode SMAW 50A 240A MIG MAG GMAW FCAW 25A 270A Polarity selection DC DC AC Shielding gas selection standard version 2 50 3 25 y 4 00 mm Wire speed selection MIG MAG GMAW FCAW 1 2 20 0m min Base material selection standard carbon steel Electrode stick selection main base rutile Electrode stick diameter selection standard 2 50 3 25 y 4 00mm Filler rod selection standard version 2 00 and 2 40 mm Diagnostic and evaluation mode standard Basic diagnostic module Power su
59. ery 15 e Operating voltage 10 30 V DC e Starting function N O contact PNP e Output current 200 mA Page 44 of 60 ITEM DESCRIPTION AND SPECIFICATION ies e Sensing distance of O 4 mm Proximity sensor inductive M18 Inductive proximity sensor on the Quick Fix secure and quick action mounting system for profile plates land cable with safety plug e 360 rotatable detenting every 15 e Size M18 e Non flush fitting e Operating voltage 15 34 V DC e Sensing distance 8 mm e Connection via the 4 mm safety connectors integrated in the Quick Fix quick mounting system e Starting function N O PNP Analog sensor inductive M12 Inductive distance sensor on the Quick Fix secure and quick action mounting system for profile plates land cable with safety plug e 360 rotatable detenting every 15 e size M12 e flush fitting e operating voltage 15 30 V DC e measuring range 0 6 mm e connection via the 4 mm safety connectors integrated in the Quick Fix quick mounting system e analogue output 0 10 V DC or 0 20 mA One way light barrier receiver One way light barrier receiver optical proximity sensor on the Quick Fix secure and quick action mounting system for profile plates and cable with safety plug e 360 rotatable detenting every 15 e size Q30 e operating voltage 10 30 V DC e light method infrared e range up to 6 000 mm e adjustable by potentiometer e connection via the 4 m
60. ey AC Auxiliary Power Supply 24Vac 230 24 Vac transformer 4 terminals 3 Double Chamber Push buttons 2 units 3 double chamber push buttons one closed and one open for actions of start stop of motors 3 pole Contactor 24Vac 4 units 3 pole contactor 9 A Control coil 24 Vac Auxiliary contacts 3NO 2NC Frequency variator Frequency voltage and currect control and programming motor specification required for programming Thermal relay GV protector module 2 units Three phase of 10A Synchronization Relay variable delay 2 regulation relays Work and rest activation time control Digital display Adjustable delay Motor squirrel cage Page 25 of 60 ITEM DESCRIPTION AND SPECIFICATION squirrel cage Three phase Asynchronous motor 270 W 3000 rpm Motor Dahlander motor 2 speeds Three phase Asynchronous motor 250 W 2800 1400 rpm b Modular Trainer for Electronics AC and DC Power supply module that allows the following output voltages Alternating 15 25V 0 5A 24V 2A Direct 24V 2A 0 20V 2A Inductances Module 9 inductances from 1 mH to 45 mH for assemblies in alternating of R L C components Capacitors Module 7 independent not polarised ones from 56 nF 470 nF po 2 polarised of 220 mF and 470 mF V Rectifier Diodes Module Rectifier diodes of 40 A 6 units Some assemblies Positive negative simple rectification Single phase and th
61. frame Round steel tube heavy duty high quality electro static powder coated Stacks 10 high from the floor Color Navy blue dark blue Storage Cabinet 1 1 20m x 1 90m Sliding Glass doors on powder coated aluminum frame with lock 18mm laminated boards with PVC edging Interactive Whiteboard 1 78 diagonal surface 4 pens 1wand wall mount USB Interface computer connection Workspace software Infrared Technology pen amp finger touch with Windows Mac or Linux Multi touch with Windows 7 aspect ratio 4 3 8000x8000 resolution Android amp IOS tablet compatible Multimedia Projector 1 USB 3LCD Projector 2800 or better Lumens White and Colour Light Output Computer Cable USB A USB B Cables Remote Control Soft Carry Case amp Manual ivil Works Program of Works Detailed Cost Estimates Drawings etc 83 Laboratory Repairs Renovation pls see details in approved EDP Note All MPS modules must be official equipment for WorldSkills Mechatronics All packages should come with complete training program laboratory manuals workbooks and Training Details A Pre delivery training at Supplier s Venue for One 1 potential expert in Mechatronics One 1 in charge of Mechatronics curriculum Duration 7 days Expenses relative to training transportation and accommodation will be shouldered by the B After delivery trainIng to be conducted at MUST No limit of the number of participants Duration of tra
62. frequency 10 mHz Input logic levels Input high voltage VIH 2 0 V min 5 25 V max Input low voltage VIL O V min 0 8 V max Output logic levels Output high voltage VOH sourcing 3mA 2 7 V min 3 3 V max Output low voltage VOL sinking 3 mA 0 07 V min 0 54 V max Overvoltage protection max 2 pins in overvoltage NI sbRIO 961x 963x 964x 20 to 550C 20 V NI sbRIO 96x2XT 20 to 850C 20 V 24 to 200C 7 V Posistor PR18BB330MS1RB from Murata Max peak abnormal condition current 760 mA Max hold current at 250C 36 mA Max hold current at 700C 20 mA Page 41 of 60 ITEM DESCRIPTION AND SPECIFICATION Max hold current at 850C NI sbRIO 96x2xXT only 3 mA Trip current at 250C 71 mA Resistance at 250C 33 Q 20 0 Analog input Number of channels 32 single ended or 16 differential analog input channels ADC resolution 16 bits Differential nonlinearity no missing codes guaranteed Integrated nonlinearity refer to Al Absolute Accuracy tables and formulas Conversion time 4 00 microS 250 kS s nput coupling DC Nominal input ranges 10 V 5 V 1 V 0 2 V Minimum overrange 10 V range 4 Max working voltage for analog inputs signal common mode within 10 4 V each channel Input impedance Al to Al GND Powered on gt 10 G Qin parallel with 100 pF Powered off overload 1 2k Q miN Crosstalk at 100 kHz Adjacent channels 65 dB Non adjacent channels 70 dB Small signal bandwith
63. ge current and reactive impedance Reactive power 4 Parallel connection of inductors 5 Series connection of inductors 6 Voltage and current over inductors Reactive impedance Reactive power 7 Series connection of a resistor and an inductor 8 Series connection of a resistor and a capacitor 9 Parameters of AC voltage and current Active power 10 Operation of transformers in open circuit mode 11 Operation of transformers in short circuit mode 12 Operation of transformers with resistive load 13 Transitory processes in RC networks 14 Transitory processes in RL networks 15 Transitory processes in RLC networks Features 17 experiments in Power Electronics e Menu driven navigation through the labs Student registration e Step by step instructions for students Interactive study guide for each experiment e Graphical representation of experimental results e Export of results in MS Excel format List of labs Operational characteristics of DC voltage generators Operational characteristics of AC voltage generators Operational characteristics of DC current generators Operational characteristics of linear voltage regulators current instability Operational characteristics of linear voltage regulators voltage instability Operational characteristics of switching voltage regulators Operational characteristics of switching voltage regulators with filter Operational characteristics of SCRs Operational char
64. graphical frame Compatible with actual Windows operating systems Configurable Software allowing the Representation of temporal evolution of different signals Visualization of Circuit tensions on the computer screen Sampling rate up to 250 KS s Kilo samples per second guaranteed 3 Three Phase transformer input and output connectors Three phase transformer 400 V a c 230 V a c 1000 VA input and output connectors 4 Single phase transformer 400 V a c 230 V a c 400 VA Ground connector 5 Variable autotransformer input and output connectors Three phase transformer 400 V a c 230 V a c 1000 VA input and output connectors 6 Resistive Inducive and Capacitance Load Module Metallic box Diagram in the front panel Variable resistive loads 3 x 150 500 W Fixed resistive loads x 150 500 W 150 500 W J nductive loads 3 x 0 33 78 140 193 236 mH 230V 2 A Capacitive loads 3x 4x7 pF 400V 7 DC Series Excitation Motor Generator Power 250 300W Speed 3000 r p m V excitation 220 V D C l Excitation nominal 0 3A V Armature 200V D C Armature nominal 1 5A 8 DC Shunt Excitation Motor generator Power 250 300W Speed 3000 r p m V excitation 190 V D C l Excitation nominal 0 3A V Armature 200V D C Armature nominal 1 5A 9 AC Synchronous Alternator Motor Power 250 300W Speed 3000 r p m Frequency 50Hz Connections Star triangle V exci
65. he general technology Especially general training aims such as the concentrated observation and analysis of systems Virtual PLC actuating with simulation using the basics of PLC programming and the logical processing of binary and analogue signals Test the program on a virtual or real model Filling with Excel Transmitted order data from MS Excel via the DDE interface e g the number and volume of the bottles Conversely the current status of the plant for example the level of the storage tanks is reported MPS PA Compact Workstation Workbook Process automation Web based training License Open and closed loop control Web based training License Easy port USB interface for measuring Open loop control Closed loop control Mechanical Components Two 2 Transparent Reservoirs Air Pressure Reservoir with Pressure Gauge Plug in tubing system Mounting Frame for Electrical Devices and Controls Aluminium Profile Plate on a Portable Trolley Sensors Two 2 Capacitive Sensors Two 2 Mechanical Contact Float Switches Ultrasonic Level Transmitter 345 mm Range Opto electronic Vane Flow Transmitter 0 7 51 min Range Piezoelectric Ceramic Pressure Sensor 0 0 4 bar Range PT100 Temperature Transmitter 0 100 deg C Range Electrical Components Signal Converters or Transducers I V f V R V Page 57 of 60 ITEM DESCRIPTION AND SPECIFICATION ny Motor Controller and Current Limiter for Centrifugal Pump s Motor 91 D igital and
66. ining 6 days during the contract period Basic Pneumatic Package 3 2 way valve with pushbutton actuator normally open 5 2 way valve with selector switch 3 2 way valve with selector switch normally closed 3 2 way roller lever valve normally closed 2pcs Proximity switch pneumatic with cylinder attachment 2pcs Pneumatic timer normally closed Pressure sequence valve 3 2 way pneumatic valve pneumatically actuated one side 5 2 way valve pneumatically actuated one side 5 2 way double pilot valve pneumatically actuated both sides 3pcs Shuttle valve OR Dual pressure valve AND 2pcs Quick exhaust valve One way flow control valve 2pcs Single acting cylinder Double acting cylinder Start up valve with filter control valve Pressure regulator valve with Pressure gauge 2pcs Manifold Plastic tubing 4 x 0 75 Silver 10 m 3 2 way valve with pushbutton actuator normally closed 2pcs Page 47 of 60 ITEM DESCRIPTION AND SPECIFICATION EE 85 Silent type Compressor Oil lubricated Extremely quiet 45 dB A compressor With pressure regulator and water separator Pressure 800 kPa 8 bar Pmax Performance 50 I min Reservoir capacity 24 Compressed air outlet 4 or KD4 Noise level 45 dB A 1 m Duty cycle max 50 Pressure regulator valve with gauge Design 230 V 50 Hz 1 roll pneumatic hose 3 mm dia Basic Electro Pneumatics with Aluminum Profile Composition 1 Signal input ele
67. interlocking case system made of light grey plastic with light blue T LOC rotary locks one hand operation for opening and interlocking the Systainers With four slots for credit card sized labels or markings TTEACHWARE 1 Workbook 1 Twelve project orientated exercises increasing in complexity and suitable for equipment set TP 201 are the ideal introduction to electropneumatics Real problem descriptions with positional sketch concrete project tasks and detailed aids for professional implementation provide the ideal preparation for ta real life industrial environment The workbook includes e Sample solutions e Training notes e Multimedia CD ROM with graphics photos of industrial applications animations and circuit diagrams Exercise sheets for trainees 2 Pneumatics and Electro Pneumatics Simulation software 1 3 WBT web based training Electropneumatics 1 4 Textbook Basic principles of pneumatics and electropneumatics 1 5 DVD Electropneumatics 1 6 Easy port USB for and interface for measuring open loop control closed loop control Simulation between hardware and software without using PLC 1 Basic Electro hydraulic Trainer with Aluminum Profile power pack and Accesories Components 1 Pressure relief valve The valve limits the pressure at port P relative to the pressure at T to the set value e Adjustment manual e Includes non return valve e Operating pressure 6 MPa 60 bar e Maximum perm
68. ion load through switches on each load branch Short circuit termination Capacitive load Resistive load fixed electric resistances and potentiometers Inductive load Cables and Accessories for normal operation Required Services Assembly and Installation Starting up Safety Maintenance amp Practices Manuals e Control Interface Box Radio Frequency generator Spectrum analyzer Stepper motor controller e Low power for safety operation under 10dBm transmission power e Radio Frequency tuning computer controlled e Frequency control and measurement from the computer PC e Wide range of frequencies in UHF band BNC connector to transmitter antenna Operate in UHF band BNC connector to receptor antenna SWR meter included in the Control Interface Box Measurement of SWR from the computer PC BNC connector to transmitter antenna BNC connector to radio frequency generator Two towers antennas Tower for the receptor antenna Tower for the transmitter antenna Stepper motor coordinate with an encoder all of these components are computer controlled e allows the full automatic 360 rotation of the transmitter antenna e EANC 1 Antennas Kit High sensibility Log periodic antenna for the receptor Monopole antenna with Ground plane Drooping monopole antenna Straight dipole antennas 2and Folded dipole antenna 2 Helical antenna right hand circular polarization Helical antenna left hand ci
69. ion mounting system for slotted profile plates 8 5 2 way solenoid valve with LED 2 Pilot actuated single solenoid piston spool valve with pneumatic spring return non detenting and detenting manual override and LED e Electrical connection via integrated 4 mm safety sockets e 24 V DC power supply e Switching time on off 7 19 ms e Pneumatic connection via QS 4 push in fitting e Operating pressure 250 800 kPa 2 5 8 bar e Quick Fix safety and quick action mounting system for slotted profile plates 9 5 2 way double solenoid valve with LED 1 Pilot actuated double solenoid piston spool valve with non detenting and detenting manual override and LED e Electrical connection via integrated 4 mm safety sockets e 24 V DC power supply e Response time 7 ms e Pneumatic connection via QS 4 push in fitting e Operating pressure 150 800 kPa 1 5 8 bar Page 48 of 60 ITEM DESCRIPTION AND SPECIFICATION eee e Quick Fix safety and quick action mounting system for slotted profile plates 10 Pressure sensor with display 1 Piezoresistive relative pressure sensor with LCD display freely programmable switching function adjustable hysteresis and analogue output for direct measured data acquisition e 360 rotatable detenting every 15 e Connection via the 4 mm safety connectors integrated in the Quick Fix quick connector system e Power supply 15 30 V DC e Switching output PNP e Analogue output 0
70. ional amplifier The attenuattion is cumulative Use of Operational Amplifier Study of Faults in filter Association of filters Behaviour of the filter Filter a distorted signal Filter in cascade low pass filter and high pass filter Filter in parallel Study of Error in filters EEE Power Electronics kit A TECHNICAL DATA Each kit contains Assembly and practice manuals 1 manual supplied Set of components and wires necessary for mounting the corresponding practice After the first assembly all the elements are recoverable KIT contents the following e Manuals e Set of practice wires e 3 bypass ceramic capacitors 100nF SOV e 2 multi layer capacitors ImF 25V diode 1N4148 4 diodes ZENER 15V diode ZENER 8 2V photo resistance e 1 red lamp 12V direct current 4 button potentiometers 100K e 1 button potentiometer 10K e 1 button potentiometer 5K e 2 resistances 10h e 1 resistance 1 8K e 2 resistances 100 ohms e 1 resistance 100K e 1 resistance 10K Page 12 of 60 ITEM DESCRIPTION AND SPECIFICATION ny resistance 120 ohms resistance 15K 6 resistances 1K resistance 2 2K resistance 220 ohms 3 resistances 390 ohms 3 resistances 4 7K resistance 47ohms 2 thyristors pulse transformer transistor Bc327 MOSFET transistor 2 transistor transistor VN10LM Dimensions 300 x 300 x 200 mm EXPERIMENTS POSSIBILITIES This kit is designed to be able
71. issible pressure 12 MPa 120 bar e Low leakage self sealing coupling nipples e Quick action mounting system Quick Fix 2 2 way flow control valve The valve ensures a constant volumetric flow rate in the flow direction from A to B regardless of the load pressure on B The oil can flow from B to A via the non return valve which opens e Actuation manual e Differential pressure of the pressure balance 0 55 MPa 5 5 bar e Operating pressure 6 MPa 60 bar e Maximum permissible pressure 12 MPa 120 bar e Low leakage self sealing coupling nipples e Quick action mounting system Quick Fix 3 One way flow control valve The valve is used to influence the volumetric flow rate through an adjustable throttle point in one direction In the opposite direction the throttle is bypassed using the non return valve e Actuation manual Integrated non return valve e Operating pressure 6 MPa 60 bar e Maximum permissible pressure 12 MPa 120 bar Page 50 of 60 ITEM DESCRIPTION AND SPECIFICATION ny e Low leakage self sealing coupling nipples quick coupling socket 4 Non return valve The valve is closed by a locking cone which is pressed against the seat by a spring When the opening pressure on the seat side is exceeded the valve opens and fluid can flow through it When the pressure on the spring side is greater the valve remains closed e Actuation hydraulic e Tube length 1000 mm e Operating pressure 6 MPa 60
72. ith bracket for mounting on a profile or profile plate The fibre optic diffuse sensor includes a holder for mounting on the conveyor guide rail profile or a slide Nominal switching distance 30 mm Power supply 24 V DC Switch output PNP normally open normally closed contact Connection cable 4 pin 8 Slide module The slide comes complete with a retainer for mounting on a profile plate Application As end slide or segregating slide Length 250 mm Standard height 117 20 mm adjustable 9 CP valve terminals 10 On off valve with filter regulating valve Filter regulator with pressure gauge on off valve quick push in connections and quick couplings mounted on a swivel support 11 Profile plate connector 12 Station link receiver 13 Electrical mounting system 14 Cable holder 15 Silent type Compressor Page 40 of 60 ITEM DESCRIPTION AND SPECIFICATION oOo O OE Oil lubricated Extremely quiet 45 dB A compressor With pressure regulator and water separator Pressure 800 kPa 8 bar Pmax Performance 50 l min Reservoir capacity 24 Compressed air outlet or KD4 Noise level 45 dB A 1 m Duty cycle max 50 Pressure regulator valve with gauge Design 230 V 50 Hz 80 Robotics Starter Kit Compatible with LABView Specifications 1 Ultrasonic Sensor Supply voltage SVDC Supply Current 30 mA typ 35 mA max Range 2cm to 3cm Input trigger positive TTL pulse 2microS min SmicroS typ
73. l Soft Carry Case amp Manual Civil Works Program of Works Detailed Cost Estimates Drawings etc 9A Laboratory Repairs Renovation pls see details in approved EDP Page 60 of 60
74. let or KD4 Noise level 45 dB A 1 m Duty cycle max 50 Pressure regulator valve with gauge Design 230 V 50 Hz Aluminium profile plate 350 x 700 mm e Grid Dimension 50mm PicAlfa module pneumatic e Universal 2 axis handling device for Pick amp Place tasks Stroke length inclination of the axes and arrangement of the end position sensors and mounting position can be adjusted Linear drive 600 mm stroke length 3 end position sensors Flat cylinder 80 mm stroke length 2 end position sensors e Pneumatic gripper e Height 700 mm e Width 220 mm e Length 730 mm e gripper Holder module Diffuse sensor e diffuse sensor can be mounted directly in the pickup module at the end of a slide or ona gripper complete with bracket for mounting on a profile or profile plate diffuse sensor includes a holder for mounting on the conveyor guide rail profile or a slide e Nominal switching distance 30 mm e Power supply 24 V DC e Switch output PNP normally open normally closed contact e Connection cable 4 pin Zz Slide module e with a retainer for mounting on a profile plate Page 34 of 60 ITEM DESCRIPTION AND SPECIFICATION ny e Application As end slide or segregating slide e Length 250 mm e Standard height 117 20 mm adjustable CP valve terminals On off valve with filter regulating valve e Filter regulator with pressure gauge on off valve quick push in connections and quick couplings
75. m safety connectors integrated in the Quick Fix quick mounting system e starting function N O PNP One way light barrier transmitter One way light barrier transmitter optical proximity switch on Quick Fix safety and quick mounting system for profile plates and cables with safety plug e 360 rotatable detenting every 15 e Size Q30 e Operating voltage 10 30 V DC e Type of light infrared e Range up to 6000 mm e Adjustable by potentiometer e Connection via the 4 mm safety connectors integrated in the Quick Fix quick mounting system e Test input Fibre optic unit Fibre optic unit optical proximity switch on Quick Fix safety and quick mounting system for profile plates and cables with safety plug e 360 rotatable detenting every 15 e Size Q30 e Operating voltage 10 30 V DC e Type of light red e Range up to 400 mm e Adjustable by potentiometer e Connection via the 4 mm safety connectors integrated in the Quick Fix quick mounting system e Starting function N O and N C contact PNP Fibre optic cable Fibre optic cable through beam sensor with polymer fibre optic cable on Quick Fix safety and quick mounting system for profile plates and cables with safety plug e 360 rotatable detenting every 15 e Maximum range 400 mm e Minimum bending radius 25 mm e Fibre optic cable length 2000 mm Retro reflective sensor Retro reflective sensor optical proximity switch on Quick Fix safety
76. ments Oscilloscope e Function generator manual control e Digital Multimeter DMM e Arbitrary waveform generator Bode analyzer e 2 wire current voltage analyzer e 3 wire current voltage analyzer e Dynamic signal analyzer DSA e Impedance analyzer e Digital reader e Digital writer e Variable power supply manual control Driver Software included e NI ELVISmx e LabVIEW SignalExpress Compatible with ELVIS platform Specifications 20 patching leads 7 optical fibers headphones user and experimenter manuals BNC copes leads Page 18 of 60 ITEM E E i 42 43 TEM DESCRIPTION AND SPECIFICATION easy to use and highly student resistant allows the student to do over 12 experiments in digital and fiber optic communications in the one self contained portable unit only requires the additional use of a PC topics covered in Experiment Manual introduction to the experimental module PCM encoding PCM decoding Sampling and Nyquist in PCM Time Division multiplexing TDM Line coding and bit clock regeneration Fiber optic transmission PCM TDM T1 implementation Optical digital filtering splitting and combining Fiber optic bi directional communication Wave division multiplexing WDM Optical losses Signal Processing Experimenter eae ce Compatible with ELVIS platform Includes 16 experiment Lab Manual covers easily be integrated or ad
77. ments are recoverable KIT Contents of the following e Manuals e Set of practice wires e 3 ceramic capacitors 1pF e 1 ceramic capacitor 100 pF e 1 bypass ceramic capacitor 100 nF e 3 capacitors ELCO 100pF e 5 switches 2 positions e 5 diodes 1 button potentiometer 10K e 2 button potentiometers 1K e 1 button potentiometer 5K e 1 resistance 1 5K e 4 resistances 100 ohms e 2 resistances 100K e 8 resistances 10K e 1 resistance 11K e 2 resistances 12K e 6 resistances 1K e 1 resistance 1M e 2 resistances 4 7K e 3 resistances 47K e 1 resistance 560 ohms e 7 transistors e 1 transistor BC557 e 2 transistors BF256A Experiments Possibilities This kit is designed to be able to do the following practices Complementary transistors pair Transistors pair with alternating signal Fault study of the complementary Transistor pair Darlington configuration Darlington configuration Fault study of the Darlington configuration Differential amplifier Differential amplifier Fault study in the differential amplifier Study and characteristics of the JFET transistor JFET characteristics Fault study with the JFET transistor Analog switch Analog switch Multistage Amplifier Direct coupling Amplifier coupled directly Fault study of an amplifier coupled directly Page 8 of 60 ITEM DESCRIPTION AND SPECIFICATION Po A SS A TECHNICAL DATA The pu
78. mounted on a swivel support Profile plate connector Station link receiver Electrical mounting system Cable holder 5 Sorting Station PLC Board Control Panel Programming cable Sorting gates with short stroke cylinder Sensors Guide rails Conveyor motor Technical data e Operating pressure 600 kPa 6 bar e Power supply 24 V DC e 8 digital inputs e 4 digital outputs Trolley e Height incl castors to bottom edge of profile plate 750 mm e Width 350 mm Depth 700 mm Control console e Fully assembled with operating panel communication panels spare panel and mounting frame with SysLink connector e Membrane keyboard Start pushbutton with LED Stop pushbutton Reset pushbutton with LED 2 flexibly assignable control lamps 4 mm safety sockets with LED status display for simple I O connection Syslink and Sub D sockets for connection to PLC of choice are available on the rear panel e fully assembled with AS interface control console communication panels spare panel and mounting frame with AS interface connector Programmable Logic Controller EduTrainer Universal Preferred versions MPS MPS PA A4 rack with built in power supply 24 V DC power supply integrated e 32 bit MIPS processor 400 MH e Data memory 32 MB flash 32 MB 20 MB flash 8 MB RAM user memory 32 KB non volatile memory e Communication network Ethernet 10 100 Base T e Integrated web server e Master CANopen e Diagnostic handheld for
79. nal load Self setting hydraulic shock absorber for smooth deceleration Suitable for the pneumatic linear drives When ordering separately please also order shock absorber bracket e Stroke 12 mm e Impact speed Maximum 3 m s e Connecting cable for linear potentiometer e Adapter for Y axis or weight e Adapter for mounting the applied load on the pneumatic linear drive unit e Mounting accessories for position encoder 16 Digital Analogue Inputs Outputs Compact PLC Educational Trainer Technical Data for the CPU e Supply power 24V DC Maximum input power 40 VA Inputs outputs e Input current IN 0 3 7 3 mA 0 20 kHz at 24 V e Input current IN 4 16 8 9 mA 0 1 kHz at 24 V e 8 relay outputs 1 2 Aat24VDC 8 FET outputs 1A The mounting system e 19 module with SysLink system connector e Suitable for ER mounting frame or unfastened on the table Page 56 of 60 ITEM DESCRIPTION AND SPECIFICATION e Lightweight injection moulded housing The unit is supplied fully assembled e Other combinations are possible via the online configurator Recommended training media Digital training programme training in PLC programming in accordance with IEC 61131 Contents e Programmable logic controllers Project organisation e Programming languages in accordance with IEC 61131 e Link orientated programming languages e Sequential function chart e Structured text e Sequence programming project e The tr
80. nductive 6x light barrier Total number of pn actuators 6 short stroke cylinders Control cabinet PLC board with frequency controller for speed variations Motor control frequency converter Communication to I O AS interface Emergency stop system emergency stop boards with two buttons on the system Operation panel ON OFF ERROR CONTROLLER Pneumatic maintenance unit pressure gauge water separator 3 2 way valve manually actuated Operation pressure 6 bar Power supply 220 V VDC with PLC 16 DI DO 4 Analog Input 2 Analog Output Vision Inspection Station Sensor 1 3 CMOS colour global shutter progressive scan Resolution 752 x 480 Pixel Optics CS Mount C Mount Digital I O 2 Inputs 3 Outputs Light Integrated ring LED light External Port for 10 100 Mbps Ethernet connection PLC 16 DI DO 4 Analog Input 2 Analog Output Automation Suite for Robot and Mechatronics System and Handling station The Automation Suite simulation software Automation Suite Robotics Automation Suite Mechatronics Automation Suite Advanced Mechatronics Automation Suite Production Production Simulation Supervision Production data management Automation Suite Studio Handling station pneumatic All rounder with pneumatic linear drive Technical data Operating pressure 400 kPa 4 bar Power supply 24 V DC 8 digital inputs 5 digital outputs Training aims for project work Mechanical Mechanical set up of a station Pneumati
81. negative and Ground connections on OFF switch The top side of the unit include a wheel to adjust the DC output voltage up to 320 Vdc 12 AC Motor Speed Controller Metallic box Output 3 PH 3 0 KVA 220 V 1 50 Hz 8 0 A Overload current thermal protection on OFF switch It has two blocks in the front panel Speed control start stop switch speed Control potenciometer Connections to motor Three phase connection to AC motor Ground connection 13 Tachogenerator Tachodynamo 60V 1000 rpm 14 Electronic Brake This unit is based in two elements 55 1 Module metallic box Power supply 1 phase 200 240V Rated output capacity 0 75 KW Output frequency range 0 2 to 400 Hz Display to visualize voltage V Current A and Frequency Hz Brake resistance included iTorquemeter R p m Meter Connectors 2 Braking motor mounted on a bench support Connection wire between elements 1 and 2 15 Computer Aided Instruction Software System complementary to the Modules formed by Classroom Management Software Package Instructor Software only one is required and common for all software packages student module software 16 Demonstration Software Student Module Software for a DC Shunt series compound excitation motor Single licence Laboratory Table 6units 2440 x 800mm 30mm laminated board table top with PVC edging with two cabinets below Powder coated steel casing fo
82. ng pressure 6 MPa 60 bar e Maximum permissible pressure 12 MPa 120 bar e Low leakage self sealing coupling nipples quick coupling socket 8 Weight 9 kg for cylinder Weight for mounting on a Learnline profile column Can be used as the driving or tractive load of a hydraulic cylinder With clevis and plain bearing guide 9 Differential cylinder 16 10 200 with cover e Operating pressure 6 MPa 60 bar e Maximum permissible pressure 12 MPa 120 bar e Double acting e Low leakage self sealing coupling nipples e Quick action mounting system Quick Fix e Piston 16 mm e Piston rod 10 mm e Stroke 200 mm e Surface area ratio 1 1 6 10 Mounting kit for cylinders Fitting a mounting kit on a cylinder makes the following possible e Actuation of the stem actuated valve by the guide bar e Actuation of proximity sensors by the permanent magnet of the guide bar e Use of a displacement encoder e Mounting kit for cylinders Suitable for cylinders Page 51 of 60 ITEM DESCRIPTION AND SPECIFICATION 11 T distributor The distributor can be inserted at any point e Ports 2x coupling nipples and 1x quick coupling socket po e Maximum permissible pressure 12 MPa 120 bar e Low leakage self sealing coupling 12 4 way distributor with pressure gauge Commissioning All quick connection couplings are connected via holes in the distributor block The coupling nipple on the side can be swapped with the blanking
83. ngle ended channels per connector Range 0 V to 5 V Absolute accurac 50 mV Current drive 3 mA Slew rate 0 3 V us MSP connector Configuration Two single ended channels Range 10 V Absolute accuracy 200 mV Current drive 2 mA Slew rate 2 V ps Audio output Configuration One stereo output consisting of two AC coupled single ended channels Output impedance 100 Q in series with 22 uF Bandwidth 70 Hz to gt 50 kHz into 32 Q load 2 Hz to gt 50 kHz into high impedance load Power Output 5 V power output Output voltage 4 75 V to 5 25 V Maximum current on each connector 100 mA 3 3 V power output Output voltage 3 0 V to 3 6 V Maximum current on each connector 150 mA 15 power output Output voltage 15 V to 16 V Maximum current 32 mA 16 mA during startup 15 V power output Output voltage 15 V to 16 V Maximum current 32 mA 16 mA during startup Maximum combined power from 15 V and 15 V power output 500 mW Power Requirements NI myRIO 1900 requires a power supply connected to the power connector Caution You must use either the power supply provided in the shipping kit or another UL Listed ITE power supply marked LPS with the NI myRIO 1900 Power supply voltage range 6 16 VDC Maximum power consumption 14 W Typical idle power consumption 2 6 W Environmental Ambient temperature near device IEC 60068 2 1 IEC 600682 2 0 to 40 C Storage temperature IEC 60068 2 1 IEC 600682 2 20 to 70
84. onfiguration function and the influence of material properties on behavior possible applications and how to select a sensor based on the application conditions The content topics are covered by exercises using magnetic inductive optical and capacitive proximity sensors The workbook includes e Sample solutions e Training notes e Multimedia CD ROM with graphics photos of industrial applications Exercise sheets for trainees e Digital training programme sensor technology 2 Sensors for object detection e 4 mm Safety laboratory cables 106 pieces red blue and black Complete set consisting of 106 safety laboratory cables with 4 mm safety plugs in the colours red blue land black e 10x red 50 mm e 10x blue 50 mm e 8x black 50 mm 8x red 300 mm e 8x blue 300 mm Page 46 of 60 ITEM DESCRIPTION AND SPECIFICATION e 18x black 300 mm e 8x red 500 mm e 8x blue 500 mm 8x black 500 mm 2x red 1000 mm 3x blue 1000 mm 2x black 1000 mm x red 1500 mm x blue 1500 mm x black 1500 mm Plugs with rigid protective sleeve and axial socket Conductor cross section 1 mm2 000 V CAT II e Rated current 16 A Working Tables 15 pcs Working Table 18 x 48 and standard height Table top using 2 face laminated light gray particle board with powder coated steel framing on wheels with all four 4 lockable rollers Polypropylene Stacking Chair 45 pcs Chair seat amp back high quality polypropylene Chair
85. onjunction with the robot station It supplies cylinder components for the assembly process A double acting cylinder pushes the cylinder caps out of the stacking magazine The pistons are stored on a pallet A double acting cylinder pushes the springs out of a slim magazine Technical data Operating pressure 6 bar 600 kPa Power supply 24 V DC 8 digital inputs 3 digital outputs Accessories Components 1 Trolley Height incl castors to bottom edge of profile plate 750 mm Width 350 mm po Depth 700 mm 2 Control console Fully assembled with operating panel communication panels spare panel and mounting frame with SysLink connector Membrane keyboard Start pushbutton with LED Stop pushbutton Reset pushbutton with LED 2 flexibly assignable control lamps 4 mm safety sockets with LED status display for simple I O connection Syslink and Sub D sockets for connection to PLC of choice are available on the rear panel fully assembled with AS interface control console communication panels spare panel and mounting frame with AS interface connector 3 Programmable Logic Controller EduTrainer Universal Preferred versions A4 rack with built in power supply 24 V DC power supply integrated 32 bit MIPS processor 400 MH Data memory 32 MB flash 32 MB 20 MB flash 8 MB RAM user memory 32 KB non volatile memory Communication network Ethernet 10 100 Base T Integrated web server Master CANopen Diagnostic han
86. ower application point is protectedagainst rotation around the longitudinal axis e Adjustable end position cushioning inboth end positions e Permanent magnet mounted on piston toallow position sensing by a suitable proximity switch This allows proximitysensing of end positions and intermediate positions More compact than lconventionalcylinders through rodless design e Type of damping Pneumatic adjustable e Buffering length 18 mm e Rotation protection Guide e Stroke length 450 mm e Overall length 650 mm e Pressure range 200 800 kPa 2 8 bar e Type of port diameter Thread G 1 8 e Usable power theoretical at 600 kPa 6 bar 295 N e Air consumption at 6 bar 0 03 I stroke Including connection and mounting material aaa 16 Position encoder Analog displacement encoder for pneumatic linear drive unit for determining the current actual position When ordering single units please also order mounting accessories The connection cable is required for use in TP 111 e Measuring stroke 450 mm e Mass 1 2 kg e Output signal at cable output of Connection cable Order no 376177 0 10 V 17 Ruler Ruler with millimeter scale printed on both sides with two knurled screws Used to measure position of the guides of the linear drive Order no 192501 e Total length 500 mm e Scale length 450 mm e Unit of measurement mm 18 Weight 5 kg for linear drive Weight for mounting on a linear drive to be used as additio
87. play for simple I O connection Syslink and Sub D sockets for connection to PLC of choice are available on the rear panel e fully assembled with AS interface control console communication panels spare panel and mounting frame with AS interface connector Programmable Logic Controller EduTrainer Universal Preferred versions MPS MPS PA A4 rack with built in power supply 24 V DC power supply integrated 32 bit MIPS processor 400 MH e Data memory 32 MB flash 32 MB e 20 MB flash 8 MB RAM user memory 32 KB non volatile memory e Communication network Ethernet 10 100 Base T e Integrated web server e Master CANopen e Diagnostic handheld for CPX terminal can be connected 1 set Desktop computer Core i3 3240 4GB 1TB Windows 7 with 19 5 inch LED monitor or better Aluminium profile plate 350 x 700 mm e Grid Dimension 50mm Cable holder Clamping ejecting module For mounting on a profile plate An electrical solenoid is used for the drive Drive with working stroke of 9 mm For mounting directly on the conveyor e Working stroke 9 mm e Voltage 24 V DC e Output 7 W Drilling module e Height 360 mm e Working stroke 100 mm e Power supply 24 V DC e Nominal current DC motor 0 3 A e Nominal current drill 0 5 A Electrical mounting system Profile plate connector Relay Rotary indexing table module e Rotary indexing table with 6 workpiece positions The table is driven by a DC geared motor with a series resistor
88. plugs mounting with protection against accidental contact with a built in lock grid ledge in the fixture for electrical port and control unit or else with plug in adaptors for the profile plate The controller comprises the following Voltage supply po as e Switching time on off 6 16 ms e Pneumatic connection via QS 4 push in fitting e Operating pressure 150 800 kPa 1 5 8 bar e Quick Fix safety and quick action mounting system for slotted profile plates Pressure gauge The pressure gauge shows the pressure in pneumatic control circuits e Design Bourdon tube pressure gauge e Display range 0 1000 kPa 0 10 bar e Quality class 1 6 4 One way flow control valve 5 On off valve with filter regulator 5 um Filter regulator valve with pressure gauge on off valve quick push in connectors and quick coupling plug mounted on a swivel support The filter with water separator removes dirt pipe sinter rust and condensed water The pressure regulator maintains the supply air pressure at the set operating pressure and compensates pressure fluctuations The filter bowl has a condensate drain valve The on off valve pressurises and vents the entire control system The 3 2 way valve is actuated by a rotary button e Design Piston regulator valve with sintered filter and water trap e Standard nominal flow rate 1600 I min e Input pressure max 1600 kPa 16 bar e Working pressure max 1200 kPa 12 bar
89. pply 115 230V 5A 11A 50 60 Hz Over power protection point at 110 130 full oad Dimensions 400x230x440 mm Weight 15 kgs Appox w o accessories 30 kgs w accessories Accessories included standard welding torches SMAW GMAW FCAW and GTAW welding mask w augmented reality 5 workpieces GTAW filler rod all necessary cables Dimensions and weight for traspo 600x800x600mm export box HxBxt Europalet Total height 700mm Total weight approx 45 kgs Security packaging ANTI SHOCK SYSTEM Processor intel core i7 3770 4 cores 3 60 GHZ speed cache 8MB Chipset intel H61 B3 express chipset Graphic board 1024 MB GDDRS Hard disc solid state 64GB SSDNow SATA2 2 5 Display Size 9 7 Display resolution HD LCD 1024x768xGA Port for external display projector VGA Augmented reality video glasses power suppy 5V Cameras resolution x2 752x480 60 fps Cameras power supply 5V Operating temperature 30 450 37 4F 113F Master software minimum hard requirements windows vista 7 processor 32bits x86 2 2 GHz 3MB graphic 215MB directX 9 0c compatible NVidia GeForce GT440 or higher ATI Radeon HD5000 or higher HDD 250MB SERVER 1 SbyOS Operating System Processor Intel i3 Core 2 4GHz 3MB RAM 2GB 2 Ethernet ports HDD 500GB Page 2 of 60 DESCRIPTION AND SPECIFICATION MID TOWER DESKTOP Personal Computer 2 Processor Intel Core i3 3220 3 3GHz 3MB L2 Cache 1333MHz FSB 65w Chipset Intel
90. r table top electrical outlets with removable front plate powder coat finish Includes wiring provisions for eight 2 gang universal outlet Powder coated Tubular metal framing with perforated plate cover for tablelegs support and adjustable metal glides iTeacher s table 1 1000x950x780mm Table 18mm Laminated Board with PVC edging Clear glass view panel for rocessed monitor approx 24 diagonal iTeacher s chair 1 Executive type Non Folded Finished Materials PU Steel PP or better Back PU or better Seat Cutting sponge with PU or better Armrest steel powder coated or of similar quality Foam High Density Foam or equiv Steel leg powder coated steel structure Color preferably Navy blue Polypropylene Stacking Chair 45 pcs Chair seat amp back high quality polypropylene Chair frame Round steel tube heavy duty high quality electro static powder coated or equivalent Stacks 10 high from the floor Color Navy blue dark blue Storage Cabinet 1 1 20m x 1 90m Sliding Glass doors on powder coated aluminum frame with lock Page 28 of 60 ITEM DESCRIPTION AND SPECIFICATION Po Civil Works Program of Works Detailed Cost Estimates Drawings etc 56 Laboratory Repairs Renovation pls see details in approved EDP LOT 8 P 8 165 000 00 1 CISCO Networking 57 CISCO 2911 w 3 GE 4 EHWIC 2 DSP 1 SM 256MB CF 512MB DRAM IPB AC Power Cord North America C13 NEMA 5 15P 2 1 m CISCO 2901 2921 IOS
91. ral Technical Specifications and incorporate them in a separate subsection The General Technical Specifications should cover all classes of workmanship materials and equipment commonly involved in manufacturing similar goods Deletions or addenda should then adapt the General Technical Specifications to the particular procurement Care must be taken in drafting specifications to ensure that they are not restrictive In the specification of standards for equipment materials and workmanship recognized Philippine and international standards should be used as much as possible Where other particular standards are used whether national standards or other standards the specifications should state that equipment materials and workmanship that meet other authoritative standards and which ensure at least a substantially equal quality than the standards mentioned will also be acceptable The following clause may be inserted in the Special Conditions of Contract or the Technical Specifications Sample Clause Equivalency of Standards and Codes Wherever reference is made in the Technical Specifications to specific standards and codes to be met by the goods and materials to be furnished or tested the provisions of the latest edition or revision of the relevant standards and codes shall apply unless otherwise expressly stated in the Contract Where such standards and codes are national or relate to a particular country or region other authoritative stand
92. rator type L Operating pressure 1 8 bar Nominal operating pressure 6 bar Nominal diameter of laval nozzle 0 45 mm QS 4 connections Max suction rate with respect to atmosphere 15 7 min With silencer plug in Quick action mounting system Quick Fix Non return valve Standard nominal flow rate 136 l min QS 4 connection Non return valve delockable Page 43 of 60 ITEM DESCRIPTION AND SPECIFICATION As long as a pilot signal is applied to the non return valve compressed air flows to and from the cylinder When the pilot signal is reset the non return valve shuts off the cylinder exhaust air and cylinder motion is stopped Suction gripper 30 SN With suction cup holder and handle Connection QS 4 or QS 6 Diameter 30 mm Suction cup material NBR Suction gripper 20 SS With suction cup holder and handle Connection QS 4 or QS 6 Diameter 20 mm Suction cup material VMQ Suction gripper 30 SS With suction cup holder and handle Connection QS 4 or QS 6 Diameter 30 mm Suction cup material VMQ Suction gripper 20 CS with vacuum security valve With suction cup holder and handle Connection QS 4 or QS 6 Diameter 20 mm Bellows structure 3 5 x Suction cup material VMQ Suction gripper 4x20 Oval With suction cup holder and handle Connection QS 4 or QS 6 Oval suction cup design 4 x 20 mm Suction cup material NBR e Protection against short circuit overload and reverse polarity e Block de
93. rcular polarization Circular loop antenna Square loop antenna Diamond loop antenna Microstrip patch antenna Yagi Uda antenna Antenna expositor RF transformer e Space required between antennas 2 3 m Complete unit includes as well e Advanced Real Time SCADA Open Control Multicontrol Real Time Control e Specialized Control Software based on Labview e National Instruments Data Acquisition board 250 KS s kilo samples per second Microwave Trainer Specifications e Microwaves signal generator lo Solid state dielectric resonance oscillator DRO lo Radio Frequency tuning lo X band range of frequencies from 8 8GHz to 12GHz e Power meter Page 20 of 60 ITEM DESCRIPTION AND SPECIFICATION e SWR meter e Crystal probe Thermistor probe Slotted line waveguide Slide Screw Tuner Crossguide waveguide Directional coupler MagicorHybrid Tee Variable attenuators waveguides Fixed attenuators waveguides Short circuit terminations Adjustable termination Dummy loads Two towers antennas one of them with azimuth indicator Horn Antennas e All the waveguide have the standard size WR90 e Cables and accessories for normal operation Exercise and practical possibilities Familiarization with a microwaves test bench Power emissions measurement Study of different Attenuation measurement O Wavelength and frequency measurement through a probe mounted on a slotted line waveguide Wavelength
94. ree phase bridge rectification Double rectification Filtrate of voltage of the assembies can be made Resistive Components Module Fixed resistances with values from 47 to 159 K ohms 14 units Linear potentiometers one of them coiled of 5 W Logarithmic potentiometers 2 units Three Phase Transformer Transformer of three branches Primary ones 220 and 380 V Secondary ones 3x73 V by branch Power 500 W Possible practices The transformer as a booster single phase The transformer as a reducer Autotransformer Star connection three phase Delta connection Transformers in series and in parallel single phase Electromagnetism Kits with group of motor generator It is based on A printed circuit with the components that can be easily seen Set of two coils Longitudinal magnet Group motor generator with its axis united Dismantled transformer kit A nucleus in U A coil with 1000 turns A coil with 2000 turns Nucleus close in I Case Electrostatic kit Ebinita bar Plexiglas bar Vertical base and hook Balls Cat skin Case for the components storage Acetate sheets aluminium sheets Electrometer Open Universal Motor Universal motor open by its sides to see inside specially the brushes c Star Delta Starter Industrial Main Power Supply Magneto thermal protection Differential protection Double plug and terminals three phase singlepha
95. rpose of Electronics and Electricity Assembly Kits is to provide the students with the necessary elements for creating their own circuits Kit Contents of the following e Manuals e Set of practice wires e 3 ceramic capacitors 1pF e 1 ceramic capacitor 100 pF e 1 bypass ceramic capacitor 100 nF e 3 capacitors ELCO 100pF e 5 switches 2 positions e 5 diodes 1 button potentiometer 10K e 2 button potentiometers 1K e 1 button potentiometer 5K e 1 resistance 1 5K e 4 resistances 100 ohms e 2 resistances 100K e 8 resistances 10K e 1 resistance 11K e 2 resistances 12K e 6 resistances 1K e 1 resistance 1M e 2 resistances 4 7K e 3 resistances 47K e 1 resistance 560 ohms e 7 transistors e 1 transistor BC557 e 2 transistors BF256A Dimensions 300 x 300 x 200 mm approx EXPERIMENTS POSSIBILITIES This kit is designed to be able to do the following practices Complementary transistors pair Transistors pair with alternating signal Fault study of the complementary Transistor pair Darlington configuration Fault study of the Darlington configuration Differential amplifier Fault study in the differential amplifier Study and characteristics of the JFET transistor JFET characteristics Fault study with the JFET transistor Analog switch Multistage Amplifier Direct coupling Amplifier coupled directly Fault study of an amplifier coupled directly Po TENDER SPEC
96. rs and cable with mounting accessories for conveyor profile e For mounting on a conveyor Complete with one double acting short stroke cylinder two sensors for end position sensing and mounting accessories 6 Mechatronic assistant 7 Coloured Laser Printer Docuprint Sppm colour and 25ppm_ monochrome print speed or better 8 Package should come with complete training program laboratory manuals workbooks and after sales support Complete Robotic System and Assembly Station ne A Robotic System High precision 6 axis articulated arm robot with extended mobility for minimal cycle times Complete with controller programming cable 1 set of batteries and the Teachbox The Robot station transports workpieces that are fed via a slide and place them in an assembly retainer The sensor in the gripper to enable the robot to differentiate workpieces by colour black non black The sensor in the assembly retainer to monitor the orientation of the workpiece From the assembly retainer the robot sorts the workpieces into various magazines or passes them on to the downstream station Combination with the assembly station facilitates the assembly of workpieces The new drive unit is small powerful and lightweight and fits into the MODULAR PRODUCTION SYSTEM MPS Technical data e Operating pressure 6 bar 600 kPa e Power supply 24 V DC e 4 digital inputs e 2 digital outputs gt Training aims for project work Mechanical
97. rs fault study Se TECHNICAL DATA The purpose of Electronics and Electricity Assembly Kits is to provide the students with the necessary elements for creating their own circuits KIT contents the following e Manuals e Set of practice wires 1 C TLO71 I C TLO72 I C TLO84 capacitor POLY 1pF O capacitors POLY 100nF e 4 capacitors POLY 10nF e 5 capacitors POLY 1nF e 5 capacitors POLY 2 2nF capacitor POLY 4 7nF 4 switches 2 positions 4 diodes 1N4148 button potentiometer 1K 3 resistances 100K 9 resistances 10K resistance 12K 9 resistances 15K resistance 1K resistance 1M 4 resistances 2 2K resistance 2 7K resistance 220K e 1 resistance 22K e 4 resistances 27K Page 11 of 60 ITEM DESCRIPTION AND SPECIFICATION e 13 resistances 3 3K e 2 resistances 3 9K e 3 resistances 4 7K e 2 transistor Dimensions 300 x 300 x 200 mm approx EXPERIMENTS POSSIBILITIES This kit is designed to be able to do the following practices Ee RC and LC filter responses Frequency response Low pass filter High pass filter LC Circuit Study of Error in Low pass filter Study of Error in High pass filter T shaped Filter Filter with double T link Generator circuit of the signal S1 Study of Error in RC filter with double T Active filters Low pass filter Low pass filter with load and operational amplifier High pass filter High pass filter with load and operat
98. s PU Steel PP or equivalent e Back PU or better e Seat Cutting sponge with PU or better e Armrest steel powder coated or of similar quality e Foam High Density Foam or better e Steel leg powder coated steel structure e Color preferably Navy blue 4 Student Stools 20 pes Molded resin seat board epoxy coated steel legs and frames with hard rubber footing 12 round wooden seat at least 1 thick e Tubular 4 legged base 18 Seat Height 5 Stacking chairs for students 50 pcs e Chair seat amp back high quality polypropylene e Chair frame Round steel tube heavy duty high quality electro static powder coated e Stacks 10 high from the floor e Color Navy blue dark blue 6 Storage Cabinet 1 e HxLxW 1 20m x 1 9m x 0 5m Sliding Glass doors on powder coated aluminum frame with lock 18mm laminated boards with PVC edging or equivalent 2 Arc Welding Machine 200A Specs Welding Amperage High 40 235A Low 30 150 A Max open circuit voltage 80 Amps input at rated output 50 or 60 Hz 1 phase 230V 47 5 2 3 Dimensions HxWxD 476mmx323mmx445mm Accessories 3 m welding cable 38mm 1 5 m grounding cable Jackson electrode holder 300A ground clamp 300 amps Page 3 of 60 ITEM DESCRIPTION AND SPECIFICATION ground clamp 300 amps 3 Arc Welding Machine 300A input power 230 400 VAC 3 phase rate output 320 A 35 duty cycle output range 50 3
99. s reservoir for sudden pressure drop and for generation of a control system with a delay of the 1st order e Design Brazed tank Capacity 400 ml e Pressure range 0 1600 kPa 0 16 bar 13 Status controller The status controller is used as a regulator in pneumatic and hydraulic position control circuits Consisting of Bus bar mass flow rail contact for 4 mm security plugs mounting with protection against accidental contact with a built in lock grid ledge in the fixture for electrical port and control unit or else with plug in adaptors for the profile plate The controller comprises the following e Voltage supply Differential inputs e Comparators e Final control elements positional control elements speed control elements acceleration lcontrolelements status controller proportional control elements integralcontrol elements differential control elements PID controller e Overall gain Status controller Correcting variable offset e Summing junction Limiter Output Technical Data e Overmodulation indicator 10 gt Ue gt 10 V e Input voltage range 13 13 V e Output voltage limitation 0 10 V 10 10 V e Correcting variable offset 5 3 5 V at 0 10 V 0 7 Vat 10 10 V e Position coefficient Kx 10 e Speed coefficient Kx 0 100 ms e Acceleration coefficient Kx 0 10 s2 e Overall gain P 0 1000 Page 55 of 60 ITEM DESCRIPTION AND SPECIFICATION 14
100. se 2 lamps 8 terminals Mushroom security button Removable key Page 26 of 60 ITEM DESCRIPTION AND SPECIFICATION Push Buttons with Light 24Vac 3 push buttons with light 24 Vac NO and NC contacts 3 pole Contactor 24Vac 3 units 3 pole contactor 9 A Control coil 24 Vac Auxiliary contacts 3NO 2NC 1 Electrical Machines Unit Basic Metallic box Diagram in the front panel Thermal Magnetic Circuit Breaker DC supply 200 V dc with fuses Connection Key Emergency stop push button Two push buttons 1NO 1NC 2 Network Analyzer Metallic box Diagram in the front panel 3 current inputs for series intensity 3 voltage terminals for each phase measure R S T and another one for the neutral connection Control and visualization digital display Voltage Range 20 500 Vrms Prec 0 5 Phase to phase Phase to neutral PO 54 eo Current Range 0 02 5 Arms Prec 0 5 Frequency Range 48 to 62 Hz 0 1Hz Power Active Reactive and Apparent Range 0 01 to 9900 kW Prec 1 Power Factor Power Factor for each phase and average Range 0 1 to 0 1 Prec 1 Operating temperature 0 to 50 C 3 Resistive Inducive and Capacitance Load Module Metallic box Diagram in the front panel Variable resistive loads 3 x 150 500 W Fixed resistive loads 3 x 150 500 W 150 500 W J Inductive loads 3 x 0 33 78 140 193 236 mH 230V 2 A Capacitive loads
101. sign e Connection via the 4 mm safety connectors integrated in the Quick Fix quick mounting system Proximity sensor inductive M12 Proximity sensor with protection against polarity reversal overload and short circuit e M12 design e 360 rotatable detenting every 15 e Connection via the 4 mm safety connectors integrated in the Quick Fix quick connector system e Power supply 10 30 V DC e N O contact PNP starting function e Quick Fix quick connector system Po Tabletop power supply unit Input voltage 85 265 V AC 47 63 Hz Output voltage 24 V DC short circuit proof Output current max 4 5A Dimensions 170 x 240 x 92 mm 4 mm Safety laboratory cables 106 pieces red blue and black Complete set consisting of 106 safety laboratory cables with 4 mm safety plugs in the colours red blue land black Ox red 50 mm Ox blue 50 mm 8x black 50 mm 8x red 300 mm 8x blue 300 mm 8x black 300 mm 8x black 300 mm 8x black 300 mm 8x black 500 mm 2x red 1000 mm 3x blue 1000 mm 2x black 1000 mm x red 1500 mm x blue 1500 mm x black 1500 mm Plugs with rigid protective sleeve and axial socket Conductor cross section 1 mm2 000 V CAT II e Rated current 16 A 2 Sensors for object detection 2units Each unit consists of the ff Accessories Components Proximity sensor magneto resistive Magneto resistive proximity sensor on Quick Fix safety and quick mounting system for profile plates e 360 rotatable detenting ev
102. splay for simple I O connection Syslink and Sub D sockets for connection to PLC of choice are available on the rear panel fully assembled with AS interface control console communication panels spare panel and mounting frame with AS interface connector 3 Programmable Logic Controller EduTrainer Universal Preferred versions rack with built in power supply 24 V DC power supply integrated 32 bit MIPS processor 400 MH D1209 D1228 Data memory 32 MB flash 32 MB 20 MB flash 8 MB RAM user memory 32 KB non volatile memory Communication network Ethernet 10 100 Base T Integrated web server Master CANopen Diagnostic handheld for CPX terminal can be connected All FEDs can be connected via Ethernet Visualisation OPC server for connection to any SCADA packages 4 Aluminium profile plate 350 x 700 mm Grid Dimension 50mm 5 PicAlfa module pneumatic Universal 2 axis handling device for Pick amp Place tasks Stroke length inclination of the axes and larrangement of the end position sensors and mounting position can be adjusted Linear drive 600 mm stroke length 3 end position sensors Flat cylinder 80 mm stroke length 2 end position sensors Pneumatic gripper Height 700 mm Width 220 mm Length 730 mm gripper 6 Holder module 7 Diffuse sensor The fibre optic diffuse sensor can be mounted directly in the pickup module at the end of a slide or ona lgripper The diffuse optical sensor comes complete w
103. stallation and Motor Controls 49 Analog Multimeter Portable analog multitester Technical Specification e DCV 0 3 3 12 30 120 300 600V 20k a y e ACV 12 30 120 300 600V 9k Q V e DCA 60u 3m 30m 0 3A e Resistance 20 200 20k Q e Battery check 1 5 Bandwidth 50 or 60Hz sine wave Battery UM 3 1 5V x e Fuse 05 2x20mm 250V 0 5A Size Mass H159 5 x W129 x D41 5mm 320g e Standard Accessories included Instruction Manual e 3 1 2 LCD display with maximum reading of 1999 e Overload protection e Auto power off function e Data hold function e Capacitance measurements e Shock Case e Mechanical protection e 2000uF test function e Diode Testing YES e Audio Testing YES e Continuity Buzzer YES e Auto power Off YES e Data hold YES e Low battery indication YES Technical Specification e Voltage DC 200mV 2V 20V 200V 1000V e Voltage AC 200mV 2V 20V 200V 700V e Direct Current 2mA 20 mA 200 mA 10A e Alternating Current 2mA 20 mA 200 mA 10A e Resistance 2000 2kQ 20kQ 200kQ 2MQ 20MQ 200MQ 51 Integrated Laboratory for Electrical Machines A Consisting of the following 1 Electrical Machines Unit Power Supply Metallic box Diagram in the front panel Thermal Magnetic Circuit Breaker Two double switches 1 NO 1 NC in each one Push Button 1 NC 1 NO Three contactors with 2 NO and 1 NC DC supply 200 V dc with fuses Connection Key Emergency stop Push button
104. t max 4 5 A e Dimensions 75 x 155 x 235 mm 4 Programming instructions for robot 5 Technical manual for robot 6 Robotics Simulation software technical documentation including instructions on processing 3D real time simulation Programming environment for IRL Industrial Robot Language programming languages Movemaster Command and robot systems Library with pick amp place tasks 7 Aluminium profile plate Sizes 350 x 700 mm e Grid Dimension 50mm 8 Cable holder 9 Angle Slide module The slide comes complete with a retainer for mounting on a profile plate Application As angled end slide or segregating slide eLength 170 mm Standard height 170 100 mm adjustable The slide comes complete with a retainer for mounting on a profile plate e Application As angled end slide or segregating slide e Length 170 mm e Standard height 170 100 mm adjustable 10 CP valve standalone PO 11 Electrical mounting system 12 Diffuse sensor e Nominal switching distance 30 mm e Power supply 24 V DC e Switch output PNP normally open normally closed contact e Connection cable 4 pin 13 On off valve with filter regulating valve Filter regulator with pressure gauge on off valve quick push in connections and quick couplings mounted on a swivel support 14 Piston pallet Pallet for the storage of 4 pistons Cylinder for assembly workpiece set 10 mm diameter and 16 mm diameter from workpiece set For cylinder ass
105. tage range 19 30 VDC Power supply current limit 1 8 A Power connector internal fuse 2 A non replaceable Max Pint NI sbRIO 961x 9612XT 7 50 W Page 42 of 60 ITEM DESCRIPTION AND SPECIFICATION Eo ES NI sbRIO 963x 9632XT 7 75 W NI sbRIO 964x9642XT 8 00 W Max PDIO 1 28 W PDIO Total DIO Current x 3 3 V 0 85 Max P5V P5V Total 5 V Output Current x 5 V 0 9 Max PCSer 3 3 W each installed C series module consumes up to 1 1 W Back up battery 3 V lithium coin cell BR2032 40 to 85 oC 14 Safety Voltages V terminal to C terminal 35 VDC max measurement category 1 15 Environmental NI sbRIO 96xx 96x2XT intended for indoor use only Ambient temperature in enclosure IEC 60068 2 1 IEC 60068 2 2 NI sbRIO 96x 963x 964x 20 to 55 oC NI sbRIO 96x 2XT 40 to 85 oC Storage temperature IEC 60068 2 1 IEC 60068 2 2 40 to 85 oC Operating humidity IEC 60068 2 56 10 to 90 RH noncondensing Storage humidity IEC 60068 2 56 5 95 RH noncondensing Maximum altitude 2 000 m Pollution degree IEC 60664 2 16 Physical characteristics Torque for screw terminals on J3 0 5 to 0 6N m 4 4 to 5 3 Ib in Weight 269 3 g 9 5 oz Sensors for Object Detection and Vacuum Technology 1 Advanced level Vacuum technology 2units Each unit consists of the ff Accessories Components Air pressure reservoir 0 4 for generating static pressure with the aid of a one way flow control valve for the generation of long time delays in
106. tation nominal 220V D C Excitation nominal 0 59A V Armature 3x220 380V 10 Three Phase Asynchronous Motor Squirrel Cage 750rpm 8poles 550w Power 250 300W Speed 2769 r p m 50Hz 3330 r p m 60Hz Connections Star triangle Frequency 50 60 Hz Page 23 of 60 ITEM DESCRIPTION AND SPECIFICATION Eo ES V Armature 230 400V 50Hz 250 440V 60Hz Armature nominal 1A 0 7A 11 Three Phase Reluctance Motor Three phase 380 V Power 200W Speed 3000 r p m Frequency 50 Hz 12 Three Phase Asynchronous Motor with wound Rotor Power 300W Speed 1413 r p m Frequency 50Hz V Armature 230 400V Armature nominal 1A 0 7A 13 Single Phase Asynchronous Motor with Starting Capacitor Power 370W Speed 2800 r p m Frequency 50Hz V Armature 230V Armature nominal 1 5A 14 Single Phase Universal Motor Power 4 8W Speed 480 14000 r p m Frequency 50Hz V Armature 230 240V Power 250W Speed 2800 r p m Frequency 50 Hz V Armature 230V 15 Single Phase Asynchronous Motor with Starting and Running Capacitor Power 370W Speed 2800 r p m Frequency 50Hz V Armature 230V Armature nominal 1 5A 16 DC Motor Speed Controller Metallic box Regulated voltage output up to 320 Vdc Maximum current output 2 A Front panel including Connections Positive negative and Ground connections on OFF switch The top side of the unit include a wheel to adjust the DC output voltage up
107. th PU or better Armrest steel powder coated or of similar quality Foam High Density Foam or better Steel leg powder coated steel structure Color preferably Navy blue Laboratory Bench Stools 40 pcs 12 round wooden seat at least 1 thick Tubular 4 legged base Steel tubing heavy duty frame 18 Seat Height Powder coated frame Color preferably Navy blue dark blue Storage Cabinet 2pcs 1 20m x 1 90m Sliding Glass doors on powdercoated aluminum frame with lock 18mm laminated boards with PVC edging Interactive Whiteboard 1 78 diagonal surface 4 pens 1wand wall mount USB Interface computer connection Workspace software Infrared Technology pen amp finger touch with Windows Mac or Linux Multi touch with Windows 7 aspect ratio 4 3 8000x8000 resolution Android amp IOS tablet compatible Multimedia Projector 1 USB 3LCD Projector 2800 or better Lumens White and Colour Light Output Computer Cable USB A USB B Cables Remote Control Soft Carry Case amp Manual ommunications and Digital Laboratory Educational Laboratory Virtual Instrumentation Suite am Platform Features Open architecture for third party plug in boards e Hi Speed USB plug and play connectivity e 1 25 MS s oscilloscope e 51 2 digit isolated digital multimeter e 15 and 5 V power supply e Manual control function generator and variable power supply e Circuit protection with resettable fuse Integrated Suite of 12 Virtual Instru
108. tion cable 4 pin 15 Desktop computer 1set Core i3 3240 4GB 1TB Windows 7 with 19 5 inch LED monitor or better Page 38 of 60 ITEM DESCRIPTION AND SPECIFICATION Po ISCADA system and visualization with control and monitoring system System visualization and operation on basis of industrial SCADA software communication between ISCADA and controllers takes place via Profibus DP PC based control and monitoring system designed for the visualization and control of processes sequences and machines The package consists of a configuration development system and a runtime system for 1024 78 N N variables PowerTags Coupling with S5 S7 Profibus DP is integrated into the system Coupling with other systems on request Supplied on CD ROM The SCADA system includes a Personal computer with TFT monitor Specs Core i3 Conveyor system MPS with Interface to Stations Dimensions main loop 3000 X 500 mm Base aluminum profiles Track with 40mm Identifications System 6 inductive sensors for identification of pallets Interface to stations 6X8 inputs 8 outputs Syslink terminal IEEE488 24 pin Pneumatic valves 6 valves 5 2 way Number of stop gates 6 Stopper short stroke cylinder type AEVUZ stroke 10mm Motor data 4 motors 3 phase 220 V Workpiece carriers 8 carriers dimensions 9x8 cm with pallet 11x16 4 cm Transportation speed p to 9m min Total number of sensors 24 18X i
109. tions for each practice Protection circuit that is used to protect each module short circuits Drive motor Asynchronous Three phase motor of squirrel cage Power 370W Speed 2730 r p m Frequency 50 60 Hz V Armature 230 400V Armature nominal 1 67 0 97A Connections Star triangle AC motor speed controller Metallic box po Power 3kVA Frequency 1 50 Hz Phase voltage 230 Vac Maximum current 8A Overcurrent thermal protection ON OFF switch It has two blocks in the front panel Speed control Start Stop switch and speed control potenciometer Connections to motor Three phase connection to AC motor and ground connection DC motor speed Controller Metallic box Adjustable voltage up to 320 Vdc Maximum current 2 A At the top of the unit there is a knob to adjust the DC voltage Front panel including Positive negative and ground connections ON OFF switch Velocity Control for stepper motor This unit is used for controlling the stepper motor assembly Metallic box Cables and accessories for normal operation Integrated Electrical Installation Laboratory a Modular Trainer AC Motors b Modular Trainer for Electronics Complete Option c Star Delta Starter a Modular Trainer AC Motors Industrial Main Power Supply Magneto thermal protection Differential protection Double plug and terminals three phase singlephase 2 lamps 8 terminals Mushroom security button Removable k
110. to 320 Vdc 17 AC Motor Speed Controller Metallic box Output 3 PH 3 0 KVA 220 V 1 50 Hz 8 0 A Overload current Thermal protection on OFF switch It has two blocks in the front panel Speed control Start stop switch Speed control potenciometer Connections to motor Three phase Connection to AC motor Ground connection B Personal Computers 2 units Desktop Computer all in one 21 5 LED monitor or higher CPU 13 RAM 4G HDD 1T DVD RW OS Windows 8 mouse amp keyboard with UPS Disassembly Machines Kit allows the student to construct operate and make more than 50 assemblies and practices of different electrical machines Specifications base plate frame ring fixed and removable bearing housings shaft squirrel cage rotor wound stator couplings armature poles and hub brushes brush holders commutator slip rings interpoles armature field and interpole coils compound field coils field coils centrifugal switch robust case for the elements necessary tools and elements for norml working operation Page 24 of 60 ITEM DESCRIPTION AND SPECIFICATION machies that may be assembled used low voltage protected rotating part operating at low power levels Panel for connections and protections Anodized aluminium structure with Panel in painted steel Diagrams for each practice which explains the different connection configurations connections box that allows to make different connec
111. truction Manual Specifications Frequency range up to 450MHz on 3 th harmonics A 100KHz 320KHz B 300KHz 1 100KHz C 1MHz 3 3MHz D 3 0MHz 11MHz E 10MHz 35MHz Page 15 of 60 ITEM DESCRIPTION AND SPECIFICATION PO F 32MHz 15OMHz Frequency accuracy 5 nn RF output 100mVrms approx up to 35MHz unloaded Output control HIGH LOW switch and fine adjuster Modulation INT 1KHz AM 30 approx EXT 50Hz 20KHz at less than 1Vrms input Audio output 1KHz Min 2 Vrms Crystal oscillator For 1 15MHz crystal in type HC 6u holder not included Power requirement AC 115 230V 50 60Hz Approx 3VA Dimensions amp weight 150 H x 250 W x 130 D mm Approx 2 5kgs Accessories BNC clips x 1 Features Wide frequency range 100KHz 150MHz With 1KHz oscillator in inner part for the purpose of modulation Of portable type high stability C Technical Specifications nput Voltage 220V AC Power consumption 550W max Air pump Diaphragm Volume 23L min max Leakage voltage of Iron Tip lt 0 5mV Temperature range of the nozzle 100 480 C Temperature range of the iron tip 200 480 C The standard iron tip AT 900M Outer Dimensions 245x187x150 LxWxH mm Specification Power Consumption 90W nput Voltage 220VAC 50Hz or 110V 60Hz Output Voltage 24VAC Temperature Range 100 500 C 212 932 F Temperature Calibration Range 50 50 F 58 122
112. using slide switches 8 Data Status Monitor Has eight buffered inputs with LED indicators that show the current state of thel inputs e 555 Based Clock Generator The circuit is based on a 555 IC configured as an astable multivibrator The signal is accessible through the OUT pin An overlapping LOW 10 Hz to 500 Hz and control as well as VR1 for fine tuning control e Pulse Generator A monostable signal generator based on the 74HC221 IC These are two outputs pressing a switch generates a pulse across the corresponding output pin e Logic Probe The probe displays the status of the signal fed across its input pins using three LED status indicators one each for HIGH LOW and PULSE e 5 Volt Power Supply This supply is the same power source used for the rest of the modules such that the user need not worry about compatibility problems when using the built in modules in the trainer All elements are mounted in a metallic box with power supply and block diagrams e Generator blocks Square signal generator Page 19 of 60 Sine signal generator Triangle signal generator Each generator block has a Radio Frequency Tuning and four BNC connectors with different line impedances 25 Q 500 750 and 1000 e Transmission line block Two transmission lines made of 40 m length coaxial cable total length joining the two transmission lines is 80 m Different test points along the lines each 10 m Fully configurable terminat
113. ware Programming cable Technical data e Operating pressure 400 kPa 4 bar e Power supply 24 V DC e 8 digital inputs e 5 digital outputs Control console e Fully assembled with operating panel communication panels spare panel and mounting frame with SysLink connector rrem po e Membrane keyboard Start pushbutton with LED Stop pushbutton Reset pushbutton with LED 2 flexibly assignable control lamps 4 mm safety sockets with LED status display for simple I O connection Syslink and Sub D sockets for connection to PLC of choice are available on the rear panel e fully assembled with AS interface control console communication panels spare panel and mounting frame with AS interface connector Programmable Logic Controller EduTrainer Universal Preferred versions MPS MPS PA A4 rack with built in power supply 24 V DC power supply integrated 32 bit MIPS processor 400 MH e Data memory 32 MB flash 32 MB 20 MB flash 8 MB RAM user memory e 32 KB non volatile memory e Communication network Ethernet 10 100 Base T e Integrated web server e Master CANopen e Diagnostic handheld for CPX terminal can be connected 1 set Desktop computer Core i3 3240 4GB 1TB Windows 7 with 19 5 inch LED monitor or better Compressor Silent type 1 unit Oil lubricated Extremely quiet 45 dB A compressor With pressure regulator and water separator Pressure 800 kPa 8 bar Pmax Performance 50 min Reservoir capacity 24 Compressed air out
114. wer 195W 315W Voltage Display Precision 0 1V 2bit Current Display Precision 0 01A 2bit Ripple and Noise lt 1mVrms Voltage Stability lt 0 01 2mV Load Stability lt 0 01 5mV Protection Method current limited lower voltage protection Environment parameters Relative humidity lt 80 Temperature range 32 104 F 0 40 Frequency Sine wave SMHz Square wave 0 1Hz 2MHz Valid Range Triangle wave 0 1Hz 1MHz Valid Range Resolution 100mHz Frequency stability 1 x10 6 Frequency error 5x10 6 Square Wave Distortion lt 0 6 Foundation frequency 1kHz Triangle Wave Linearity _98 100mHz 100kHz _95 100kHz 1MHz Square Wave R ising amp falling time lt 30ns ITTL CMOS Amplitude _3 Vp p Fan Out 20TTL Load CMOS level 3 5 13 5 Vp p Options Power Output Output Power _10W 4_Load Output Wave sine wave Frequency range 20Hz 40kHz Counter Measure frequency range 1Hz 40MHz Measure Voltage range _ 0 2V Error range 1x10 4 Others Supply voltage A C 2 2 0 V 10 50Hz 5 Line voltage setting is factory installed 20 and 400 kHz resolution bandwidth 150kHz hour stability Built in tracking generator Frequency Counter 10Hz 2700Mhz Features 8 Digit LED display Few switches for easy operation Quickness high resolution Gate time 0 01S 0 1S 1S Accuracy 1Hz 1 Count Figure Time Base Page 14 of 60 ITEM DESCRIPTION AND SPECIFICATION fe Accuracy Input Sensitivity 10Hz 8MHz
115. x black 1000 mm e 1x red 1500 mm e 1x blue 1500 mm 1x black 1500 mm e Plugs with rigid protective sleeve and axial socket e Conductor cross section 1 mm2 e 1000 V CAT II e Rated current 16 A 21 Laboratory Workstation with Aluminium profile plate 700x1100mm and ER frame The anodised aluminium profile plate forms the basis for all training packages All of the components fit securely and safely into the grooves on the profile plate There are grooves on each side and if required both sides can be fitted with components The grooves are compatible with the ITEM profile system Grid dimensions 50 mm Sizes 350 x 1100 mm and 350 x 250 mm supplied without side caps H x W 22 Hydraulic power pack with a constant displacement pump 230 V Ideal for individual hydraulic workstations for all experiments using standard equipment sets TP 500 Closed loop Pneumatic Trainer Advanced Electro Pneumatics Equipment Set Accessories Components 1 Signal input electrical 2 3 2 way valve with pushbutton actuator normally closed Pilot actuated single solenoid piston spool valve with pneumatic spring return non detenting and detenting manual override and LED e Electrical connection via integrated 4 mm safety sockets e 24 V DC power supply Switching time on off 6 16 ms e Pneumatic connection via QS 4 push in fitting e Operating pressure 150 800 kPa 1 5 8 bar e Quick Fix safety and quick action mounting syst
116. y assembled with AS interface control console communication panels spare panel and mounting frame with AS interface connector Programmable Logic Controller EduTrainer Universal Preferred versions MPS MPS PA A4 rack with built in power supply 24 V DC power supply integrated 32 bit MIPS processor 400 MH e Data memory 32 MB flash 32 MB 20 MB flash 8 MB RAM user memory 32 KB non volatile memory e Communication network Ethernet 10 100 Base T e Integrated web server e Master CANopen e Diagnostic handheld for CPX terminal can be connected Desktop Computer 1 set Core i3 3240 4GB 1TB Windows 7 with 19 5 inch LED monitor or better Aluminium profile plate 350 x 700 mm e Grid Dimension 50mm Cable holder Changer module CP e Cylinder rotation angle rotary cylinder 180 freely selectable e Height 130 mm Width 130 mm Length 250 mm CP Valve terminals Electrical mounting system e Comprising 2 cable ducts 340 mm and DIN rail 340mm with mounting accessories for securing to profile plate Minor accessories On off valve with filter regulating valve e Filter regulator with pressure gauge on off valve quick push in connections and quick couplings mounted on a swivel support Profile plate connector Stacking magazine module e Consisting of double acting cylinder with inductive sensors and cables magazine separator and magazine tube The speed with which The cylinder extends and retracts can be set via one way

Download Pdf Manuals

image

Related Search

Related Contents

Control Inversor Serie 15H  PEE POD 500 - ARRI Rental  Kudu User Guide  HDX DN-10030 Installation Guide : Free Download, Borrow, and Streaming : Internet Archive  Giada A50 - Manual Eng  Guía rápida instalación Servicio JAZZTEL  取扱説明書  Manual  Réf: fiche N“ 1 - Mohair France  Mode d`emploi SikaBond Dispenser 1800 Power au 12.12.2011  

Copyright © All rights reserved.