Home

4 Libraries and System FP

image

Contents

1. FBSLO3 Blocks for configuring SIMOVERT D processor programs IBSLIB Initialization blocks for standard boards and standard communication connections The library name syntax makes a differentiation between FBSxxx Standard function block libraries IBSxxx Standard initialization block libraries FBAxxx User function block libraries IBAxxx User initialization block libraries A maximum of 3 FB libraries in addition to FBSLIB for FP configuring or 3 IB libraries in addition to IBSLIB for MP configuring can be used to configure a processor program The current library assignment is displayed in the basic dialog after clicking on the library function SIEMENS Basic Dialog STRUC L 4 2 1 P32 P16 SIMADYN D Da i Fie MP Edit FP Edit MP Compile FP Compile PN Compile Prog Auto Comp Version Library Options Select libraries Basic software GSW V420 950401 FB libraries Version Release P16 P32 Version Release P16 P32 fbslib V420 950401 x x ibslib V420 950401 x x A A C C OK Siemens AG 465 982 7101 21 Edition 06 95 Fehler Nur Hauptdokument 3 SIMADYN D STRUC L User Manual 4 Libraries and System FP The standard library assignment shown in the example can be found after installing the floppy disk set The library assign
2. Yes No Fehler Nur Hauptdokument 5 4 Libraries and System FP 4 1 4 Load libraries When configuring user libraries before the select libraries function is called up these libraries must first be loaded into the configuring unit For STRUC L 4 0 this must be realized at the MS DOS level it is practical to address using wild cards e g copy a f al21 c struc_w struc bib Library fba121 is copied from the floppy disk in drive A to drive c in the bib directory 4 1 5 Version administration and library generation Libraries are generated using the function block generator The library version ID and the block names which are combined to form a library are the generating parameters For the standard FBSLIB the version code for the system software and library version code are identical 950401V420 The version code comprises STRUC L 4 2 1 Version V420 Status 950401 For version V4 there are 5 status delivered so far STRUC L 4 0 STRUC L 4 0 1 STRUC L 4 0 2 STRUC L 4 0 3 STRUC L 4 2 V400 V400 V400 V400 V420 930315 940415 940601 940815 940901 The following compatibility rules are valid for libraries A B and C If the system software and library options are identical then a version adaption is possible System software and library are compatible If the versions are not identical version adaption is only possible if the system software version library version System
3. 4 Libraries and System FP 4 Libraries and System FP Contents 4 1 EIDFARIES aes tea et tt Peete tat Peete ttn tetas ten Pete a alk o 4 3 4 1 1 Library assigninent 4 40 440 inne ae ice ie eee ee 4 3 4 1 2 Select libranles yc a a eee a note tee 4 4 4 1 3 Ghange library assignments2 3 2 2 Ae Sh a a aa a a a has ha 4 5 4 1 4 Eoad lbrares etek ee UR tek ae ak Dat erat Sata ga a hahd 4 6 4 1 5 Version administration and library generation c cccccceceeccceeeeeeeeeeeeeecaaeeeeeeeeeeeecdaeeeeeeeeeseeenaaaes 4 6 4 1 6 MAGChONID FAY eet te aE Aas i eek tae ae al a a a 4 6 4 1 7 Version adaption with the Version menu ccceeeeeeeeeeeeeeecceeeeeeeeeeeecaaaeeeeeeeeeteecdaaeeeeeeeeeeeeenaaaes 4 7 4 2 Process System FP wie eee A Ae 4 8 4 2 1 Configuring the system FP cccccccecccecccenee teeter eee ee cca ee teen eee eteeaaeee sees eeeeeeaaaeeeeeeeeeeeecaaaeeeeeeeeeneeeaaaes 4 8 4 2 2 Invoking System FP ae EA R 4 8 Siemens AG 465 982 7101 21 Edition 06 95 Fehler Nur Hauptdokument 1 SIMADYND STRUC L User Manual 4 Libraries and System FP Fehler Nur Hauptdokument 2 Edition 06 95 Siemens AG 465 982 7101 21 SIMADYN D STRUC L User Manual 4 Libraries and System FP 4 1 Libraries 4 1 1 Library assignment Function and initialization blocks are organized as libraries Standard blocks are assigned technology related to libraries FBSLIB Generally applicable blocks for PM PG and PT processor programs
4. al 4 Libraries and System FP SIEMENS Basic Dialog STRUC L 4 2 1 P32 16 SIMADYN D ww a File MP Edit FP Edit Library Options MP Compile FP Compile PN Compile Prog Auto Comp Version 4 I Select libraries Basic software GSW V420 950401 FB libraries Version Release P16 P32 B libraries Version Release P16 P32 fbslib V420 950401 x x ibslib V420 950401 x x A A fba121 V420 950401 xX X C C OK If for example the field behind C is clicked on a window opens with all stored FB libraries In this case library fba121 is no longer displayed as it is already assigned If this selection is confirmed with OK the select libraries window is closed and the system returns to the basic dialog The same procedure is true for IB libraries 4 1 3 Change library assignment If the library assignment must be changed then the cursor is clicked on the name of the already assigned library in the example library fba121 in field B Using the deselect library yes no in the opened request window the library assignment is now deleted by clicking on yes Now another library can be asigned as described in Section 4 2 Siemens AG 465 982 7101 21 SIMADYN D STRUC L User Manual Edition 06 95 2 Deselect library
5. appear If the SYS FP is not or uncompletely copied then this is confirmed by the following message Fehler Nur Hauptdokument 8 Edition 06 95 Siemens AG 465 982 7101 21 SIMADYN D STRUC L User Manual 4 Libraries and System FP SYS FP lt ip name gt not available e Message SYS FP lt fp name gt not compiled SYS FP lt fp name gt not available for P16 and P32 SYS FP lt fp name gt not available for P16 SYS FP lt fp name gt not available SYS FP lt fp name gt not available for P32 SYS FP lt fp name gt not available for P16 and not compiled for P32 SYS FP lt fp name gt not available for P32 and not compiled for P16 SYS FP lt fp name gt not compiled for P16 SYS FP lt fp name gt not compiled for P32 Siemens AG 465 982 7101 21 Edition 06 95 Fehler Nur Hauptdokument 9 SIMADYN D STRUC L User Manual Drives and Standard Products Group Drive System Division P O Box 3269 D 91050 Erlangen Drives und Standard Products from Siemens i i Subject to change without notice Item No 465 982 7101 21 Siemens Aktiengesellschaft Printed in the Federal Republic of Germany 0695
6. e MP or FP must be selected and then using the cursor Version Match Version and Selected FP or Selected MP must be selected the adaption program then starts If all FPs of the master or processor program are to be adapted then the next two menu items can be appropriately selected In this case either the MP or the PN must be selected If MP or FP with an older status is edited then the editor announces that by Version adaption Y N Clicking Y carries out the version adaption by the editor Better use the basic dialog function Version Match Version because a adaption then can be carried out in all FPs and MPs If MP or FP header mask is changed opposite to the old version then these only can be adapted with the function Version Match Version but not with the editor Siemens AG 465 982 7101 21 Edition 06 95 Fehler Nur Hauptdokument 7 SIMADYN D STRUCL User Manual 4 Libraries and System FP 4 2 Process system FP The standard system function packet is called SIMD and is configured in the master program as standard The user can configure other system FPs with other names till now but he cannot create a system FP To create and process a user owned system FP two new sub directories are installed to the user path from STRUC 4 2 1 on They contain of all user owned system FPs for 16 Bit and 32 Bit processors awd pjsyfp symp16 awd pjsyfp symp32 They contain the master programs SYMP16 and SYMP32 for editing and compi
7. ling the system FP While delivery the source and target files of the standard system FP SIMD is stored there The user can create his own system FP by new configuring or modificating of SIMD 4 2 1 Configuring the system FP For configuring the system FP in the corresponding master program enter SYS FP name in the header mask and SYS FP transmitter FP in the processor mask This is necessary for selecting the SYS FP in the basic dialog Further on all known restrictions must be observed Basic sampling time 1 ms Sampling time T1 Name convention lt name gt P16 lt name gt P32 Further on observe that all user system FPs must be adapted to version and compiled for new system libraries The name of the user system FP should be lt gt SIMD because otherwise the user system FP will be overloaded by the standard system FP while up date installation of a new STRUC version 4 2 2 Invoking system FP Up to now the object code P16 c simd obj P32 c simd3 o and the FP neutral code global P16 simd gfp P32 simd3 gfp are copied into the user directory while selecting a MP in the basic dialog or after editing MP From version V4 2 1 on the algorithm is changed in that way The name of the system FP is read from the selected MP the names of the object code files and FP neutral code files that must be copied are created and the files are copied from path pjsyfp If the SYS FP is copied completely then no message does
8. ment is stored in each FP and MP If the selected library assignment and the assignment selected when generating the FP do not coincide then the FP DIA function is aborted with a error message The same is true for MP configuring for IB libraries In this case the current library assignment must be appropriately changed refer to Section 4 1 3 4 1 2 Select libraries After the select libraries function was called using the library function in the basic dialog additional libraries can be assigned as libraries A B and C Click on the field behind A B or C using the cursor and a window opens with all of the stored FB libraries E SIEMENS Basic Dialog STRUC L 4 2 1 P32 16 SIMADYN D e Fie MP Edit FP Edit MP Compile FP Compile PN Compile Prog Auto Comp Version fba121 fosl03 950401 P16 P32 B libraries Version Release P16 P32 x x ibslib V420 950401 x x A library can be selected using the cursor It is then provided with a black background The selection must then be confirmed with OK and its name appears in the field after the library e g assignment of library fba121 as library B Fehler Nur Hauptdokument 4 Edition 06 95 Siemens AG 465 982 7101 21 SIMADYN D STRUC L User Manu
9. software and library are upwards compatible If this system software version changes the blocks must be adapted and the libraries generated using modified version code The insertion of blocks in a library represents a compatible change 4 1 6 Macro library From version V 4 2 on not only function blocks but also with STRUC G created and error free compiled macros are invoked in the same way as function blocks The invokable macros are stored in the sub directories of the path struc awd project macros The macro path with 8 sub directories in maximum corresponds with a macro library assigned to a project Fehler Nur Hauptdokument 6 Edition 06 95 Siemens AG 465 982 7101 21 SIMADYN D STRUC L User Manual 4 Libraries and System FP 4 1 7 Version adaption with the Version menu Versions can be adapted via the menu as not all version adaptions can be made using MP and FP DIA An MP or FP header mask changed over with respect to the old version cannot for example be converted using MP and FP DIA SIEMENS Basic Dialog STRUC L 4 2 1 P32 P16 SIMADYN D a File MP Edit FP Edi MP Compile FP Compie PN Compile Prog Auto Comp MARKON Library Options Selected MP Match Version FP Transformation P16 i i lected FP P Create Project Master Program S ee ore All FPs of the PN T7 me EER All FPs of the MP O O O O 22229 exampl The appropriat