Home

Control Panels in the VikinX Sublime series User manual

image

Contents

1. Control Panels in the VikinX Sublime series User manual Rev 11 VikinX Sublime Control Panels Rev 11 Nevion Support Nevion Europe Nevion USA P O Box 1020 1600 Emerson Avenue 3204 Sandefjord Norway Oxnard CA 93033 USA Support phone 1 47 33 48 99 97 Toll free North America 866 515 0811 Support phone 2 47 90 60 99 99 Outside North America 1 805 247 8560 E mail support nevion com See http www nevion com support for service hours for customer support globally Revision history Current revision of this document is the uppermost in the table below Rev Repl Date Sign Change description 11 10 2011 12 12 NBS AAA Corrected protocol options in Chapter 3 7 Appendix B removed Alarm list in Chapter 4 2 updated 10 9 2011 08 22 NBS Updated Chapter 7 1 2 9 8 2011 07 14 NBS Added Error Reference source not found Added Grass Valley Native Protocol in Chapter 3 7 and Appendix B 2 Added Chapter 7 1 10 Changed Chapter 7 1 1 Updated Declaration of Conformity 8 7 2011 03 29 NBS Updated Chapter 3 3 and 3 7 Corrected housing and gender spec on D sub 9 pin contacts Added Declaration of Conformity Removed old Revision history 7 6 2011 01 04 NBS Updated information about configuration of GPI fallback input Chapter 3 2 1 Updated protocol options in Chapter 3 7 Added comment on redundant controller support in Chapter 5 2 6 5 2010 08 13 NBS Updated Chapter 3 6 Adde
2. 1 for more information 3 2 Fallback mode This information is only applicable on GPI versions with the Joystick release mode enabled See Chapter 3 5 Switch 5 on the configuration switch sets the fallback mode of the GPI panel either to dynamic or to hard set Dynamic fallback mode When the GPI is activated the X point status is saved before switching When the GPI is released again the panel will switch back to the previous saved X point status Hard set fallback mode When the GPI is released the panel will switch to a previously configured fallback input The fallback input is configured using the input buttons The modes can be switched according to the following pattern SW 5 Fallback mode OFF Hard set ON Dynamic Default mode is Hard set nevion com 8 VikinX Sublime Control Panels Rev 11 gt 2 1 Configuration of fallback input Enable the panel 2 Press and Hold the Panel Enable button and then press the A V Toggle button 3 While still holding Panel Enable select the fallback input by pressing the associated Input button Release the Panel Enable button The panel will now be disabled Press the Panel Enable button again to enable it 3 3 Joystick priority This information is only applicable on GPI versions Switch 6 on the configuration switch set the Joystick priority of the GPI panel either to release before switch or to switch before release The rel
3. 15m Longer distances can be installed depending on the environmental conditions of the installation site It is the responsibility of the installer user to secure a proper installation of the RS 232 connection nevion com 13 VikinX Sublime Control Panels Rev 11 5 2 Ethernet connection The connections follow the standard set by the IEEE 802 3 100BaseTX specification The cables that are to be applied should be CAT 5 CAT 5E standard or better It is the responsibility of the installer user to secure a proper installation of the Ethernet connection All VikinX Sublime routers and IP based Control Panels are connected together through an Ethernet Switch A VikinX Sublime device has only one physical Ethernet connection If redundant control is required this limitation has to be solved by the control system Sublime Control Panels do not support redundant controller setup Use VikinX IP based control panels for that purpose For Ethernet protocol details concerning this router please refer to the following manual Modular Router Control Protocol This manual can be found on our web site htto www nevion com 5 2 1 HW limitations With the introduction of Sublime controller HW Rev 2 the user has the option of connecting more than two devices together without having a Multicon to control the network See Chapter 3 7 for verification of the HW revision of your device Unless you apply a Multicon as a system contr
4. WEEE EU Directive 2002 96 EC REACH EN 55103 1 1996 EN 55103 2 1996 Notified Competent Body Report no Nemko E08443 01 Not applicable 2008 AUTHORIZED REPRESENTATIVE Established within EEA Date of Issue 2011 04 03 Place of Issue Not applicable Sandefjord Norway 3 Administration on the Control of Pollution Caused by Electronic Information Products nevion com 25
5. have opto coupled inputs nevion com 16 VikinX Sublime Control Panels Rev 11 6 GPI connections This information is only applicable on GPI versions The GPI Joystick Tally signals are connected to the Sublime Control Panel with GPI options using DB25 male connectors Each Sublime CP with GPI I O has 32 GPI inputs and 32 GPI outputs available independent of panel size The GPI connectors on the CP are DB25 females The following pin out applies GPI I O Channel Connector pin 1 and 17 12 2 and 18 24 3 and 19 23 4 and 20 10 5 and 21 09 6 and 22 21 7 and 23 20 8 and 24 07 9 and 25 06 10 and 26 18 11 and 27 17 12 and 28 04 13 and 29 03 14 and 30 15 15 and 31 14 16 and 32 01 Inputs are internally connected to 5V via a pull up resistor The inputs will be activated when pulling them to ground Ground is available on the following pins 2 5 8 11 13 16 19 22 25 and on the connector chassis Outputs are of open collector type An output can switch a maximum load of 100mA at 30V Any device to be controlled by the GPI outputs lamp LED or similar needs to be connected to an external supply voltage on one end and to the GPI output on the other end Warning Do not connect external supply voltages higher than 30V DC nevion com 17 VikinX Sublime Control Panels Rev 11 7 Control Panel operation All local control pan
6. not be executed until the Take button is pressed nevion com 19 VikinX Sublime Control Panels Rev 11 The maximum router size s that may be controlled without Multicon is formed by IN 1 128 and OUT 1 64 router size 128x64 This size limitation is regardless of the number of routers the control panel s is are controlling See also the limitations 1 and 2 in Chapter 5 2 1 7 1 8 Salvo A Salvo button switches a sequence of cross points This is done even if the specified audio or video level is disabled The following limitations on the number and size of salvos in Sublime external CP s apply Maximum 4 levels audio video each up to 128 X points Maximum 20 salvos of max 64 X points The following limitations on the number and size of salvos in Sublime local CP s included in router apply Maximum 1 level audio video up to 128 X points Maximum 20 salvos of max 64 X points 7 1 9 Lock A Lock Toggle button toggles the lock status on the active output on all enabled audio and video levels If the active output on any of the enabled levels is locked before pressing the button they will be unlocked If not the active output on all enabled levels will be locked A locked output can t be switched 7 1 10 Protect A Protect Toggle button toggles the protect status on the active output on all enabled audio and video levels If the active output on any of the enabled levels
7. the extra commands that were added to the NCB protocol when we introduced the Sublime router range either off or on At the same time the user must select whether he she shall use the RS 232 port for controlling the router or the Ethernet port This is done in order to prevent both ports from simultaneously being applied for controlling the router There is a new Protocol field in the System Configurator where you may choose from the following options NCB without Sublime ext RS232 This is the old Compact NCB protocol without Sublime extensions If used ona Sublime it also disables the Ethernet port of that device NCB RS232 This is the regular Sublime protocol with the extra commands that were added to the NCB protocol If used on a Sublime it also disables the Ethernet port of that device This is the default option for the Sublime SL range of products MRP TCP IP This option is only applicable to the Sublime range It selects the Ethernet protocol as the control option and disables the RS 232 port of that device This option allows the user to control Sublime routers that have other 3 party TCP IP protocols enabled MRP is always enabled on Sublime routers when they are configured for 3 party TCP IP control protocols Note that the above selection is only possible if you have Sublime FW rel 2 1 1 or newer installed on your Sublime device and System Configurator rel 3 3 5 or newer installed on y
8. video is present it will be marked as disabled and the toggle state will not be used Toggle status changes will be stored in flash and used when the panel is powered up later The following information is only valid for Sublime FW version 2 5 3 and older If neither audio nor video is present it will be marked as disabled and the toggle state will not be used When a panel is powered on it will search for connected routers If no routers are found the A V Toggle button will be disabled no light in the button nevion com 18 VikinX Sublime Control Panels Rev 11 This can happen if the panel is powered up before any routers are connected or if there is something wrong with the cabling To re enable the A V Toggle do the following 1 Activate the Panel Enable button Green light 2 Push amp Hold the A V Toggle button for 2 seconds The A V Toggle button should now be activated and the light turned on 7 1 2 Panel Enable The panel always starts in disabled mode In this state the button will be red and all the other buttons will be disabled When pressing the button the panel will be enabled and the color will change to green A status request will also be sent to get information on active levels 7 1 3 Take on off The Take on off button enables or disables the Take button If no take button is defined Take on off is always off On first start up the take button is enabled Later it will read the la
9. 3 5 Joystick mode This information is only applicable on GPI versions Switch 8 on the configuration switch set the Joystick mode of the GPI panel either to GPI mode or to Joystick release mode GPI mode Releasing the input lines will keep the previous status Operation of the front panel is allowed with any number of active GPl lines simultaneously nevion com 9 VikinX Sublime Control Panels Rev 11 Joystick release mode When all the input lines are released a default input either dynamically chosen or static is set The front panel is locked if any of the input lines are active The modes can be switched according to the following pattern SW 8 Joystick mode OFF GPI mode ON Joystick release mode Default mode is GPI mode 3 6 Configuring active output on Single bus panels Use the Input button to select the active output on single bus panels It requires that a Panel Enable button is present When the panel is enabled press the Panel Enable button and hold it while selecting the active output by pressing an Input button Then release the Panel Enable button The panel will now be disabled Press the Panel Enable button again to enable it Example If you want your Single Bus panel to control Outout 7 of your router follow the procedure described above pressing Input 7 3 7 Configuring protocol options For various reasons Nevion has decided to make it possible to turn
10. 6 W 0 35 kg N A AC Mains 40W Power Supply Unit 100 240VAC 50 60Hz Max 1 6A IEC 320 15V max 2 2A 15V max 1 35A Maximum 43W DE9 D sub 9 pin male Via LED in front of the router CP Compliant with CE EN60950 UL 1950 CSA22 2 RS 232 for protocol conversion to VikinX compact control protocol or to third party protocols DE9 D sub 9 pin female For integration with VikinX compact router configuration RJ45 1 In 1 Out 10 100BaseT Ethernet bus for external router control RJ45 nevion com 6 VikinX Sublime Control Panels Rev 11 2 4 Connection details The Sublime routers and control panels have the following service connections on the rear of each product SN CONFIGURATION DIP 1 4 ADDRESS LEVEL DIP 5 6 ROUTER MODE DIP POWER ALARM DIPS POWER UP MODE K CE ICS ASA Made in Norway NCB IN NCB OUT ETHERNET RS 232 POWER A N j gt o o o o o on o o o go JJ OO A C Figure 1 Sublime service connectors SYNC Not in use on Control Panels LOOP Not in use on Control Panels NCB IN Network Control Bus Input The protocol of this bus is described in a separate manual NCB OUT Network Control Bus Output ETHERNET 10 100Base T Ethernet bus for external router control RS 232 RS 232 for external control protocols POWER A 15VDC power connector POWER B 15VDC power connector redundant supply CONFIGURATION Configurations swit
11. T Sublime ref HD3232 R CP 10 10 11 130 255 255 240 0 10 10 10 254 None ass 32432 hd router CP CP DIP 4 203 2 0 3pre3 00 00 39 FF 00 34 JGS_SL D32P_rev2 Sublime sL spo808 N CP 192 168 1 10 255 255 255 0 192 168 1 1 None see 8x8 sd router CP DIP 2 105 105 00 00 29 04 02 08 ref HD3232 R CP__ Sublime THOR_SL 8XY CP 10 10 1223 255 255 240 0 10 10 10 254 10 10 10216 CP DIP 0 103 00 00 39 FF 00 33 SL SD0808 N CP__ Sublime aaa_gpio 10 10 1327 255 255 240 0 10 10 10 254 aaa_ethcon eee CP DIP O 2 0 4pre1 203 00 0D 39 FF 00 39 THOR_SL 8XY CP Sublime aa Figure 2 HW verification in Nevion Configurator Right click the column headers and select the appropriate column to be shown if you don t see the appropriate column in your default display For further information about FW releases please go to the Nevion web site to download or check available FW releases www nevion com nevion com 11 VikinX Sublime Control Panels Rev 11 4 LED status indication 4 1 Start up The LED located at the front of the control panel indicates the status of the panel At start up the LED will alternate between red R and green G every 500ms for about two seconds After the start up sequence the LED will indicate the Alarm state of the panel There are two LEDs located at the Ethernet bus At start up the boot loader is searching for update commands on the serial port for about two seconds During this sequenc
12. ch See Chapter 3 for further descriptions 2 4 1 Power Supply pin out The DE9 male sockets for the power connection on Sublime routers and Control Panels have the following pin out Pin Description GND Not connected Not connected 15VDC Not connected Not connected Not connected 15VDC Not connected CO CO NI Od 01 AOIN S nevion com 7 VikinX Sublime Control Panels Rev 11 3 Configuration This chapter provides an overview of the configuration options that are available on the Sublime Control Panels 3 1 Level configuration Switches 1 4 on the configuration switch set the CP s level for communication with the Router Management System and other units in the NCB system Panels on the NCB dedicated to operate with the router must be configured to the same level as that router The levels can be switched according to the following pattern SW1 SW2 SW3 SW4 Level NCB Address OFF OFF OFF OFF 1 0 OFF OFF OFF ON 2 1 OFF OFF ON OFF 3 2 OFF OFF ON ON 4 3 OFF ON OFF OFF 5 4 OFF ON OFF ON 6 5 OFF ON ON OFF 7 6 OFF ON ON ON 8 7 ON OFF OFF OFF 9 8 ON OFF OFF ON 10 9 ON OFF ON OFF 11 10 ON OFF ON ON 12 11 ON ON OFF OFF 13 12 ON ON OFF ON 14 13 ON ON ON OFF 15 14 ON ON ON ON 16 15 Default level is 1 It is possible to control more than 1 level with Sublime panel See Chapter 7 1
13. d salvo limitations in Chapter 7 1 nevion com 2 VikinX Sublime Control Panels Rev 11 Contents ra A A AE 5 13 1 PrOdUCt VEPSIONS ida 5 2 Specifications sina a A EEE 6 Oli MECHANICS we nra dai e EA Dt a Pee 6 2 1 1 Weight and power consumption ooooooocccccnccnncncnnonccnnnconnnnnnnnnannnonnnonannnnnnnnnnnnncninano 6 2 2 POWER SUPPI int di 6 DONT re cha At e Ad o e A el ado e EEEE 6 2 4 Connection 0etallS ooocccconcncnncccnnocinnncncnnancnnncnnonancnnn A 7 2 4 1 Power Supply pin out ra ico 7 O CONMOQUIAUON se conse ted co o ee to 8 Sl ESV COMMGUFALION artis 8 3 2 Fallback Mode ut a holden eect aie eee eat ate ok kde ches ie Se le aie cade 8 3 2 1 Configuration of fallback input cuanta 9 3 3 Joystick PION ity ito dl a EEE AEGA 9 34 O Ee AE 1 a ois RRE E EEE ETE E EEEE E OE EPE EOE 9 3 5 Joystick mode 3 sae gen ete lea atc eae Mees ac A OE 9 3 6 Configuring active output on Single bus panels seeeseeseessesseeeeseeeeeeeeeeeeeeees 10 3 7 Configuring protocol Options section dendeevetes tented es 10 4 LED status Mac alo Massanassa dd 12 4l otar Upe eee e a e a e a set relent aacach aed S 12 42 Alarm Stalo Sana Ari 12 4 3 Ethernet states aa a r E a O a E EA PEAR 12 5 Router COMMUNICATION ni n au dis 13 Sena COMME e i e a AA Snae E EA AEEA EE E EE TER E 13 5 1 1 Maximum cable length RS 232 ita 13 5 2 Ethernet CONMECHON esere iii 14 A Ac ET T 14 5 SNCB COMECON reinn a
14. dde bid 15 5 3 1 Connecting control Pana Suso dake dscrrscpdacceisniacted es dedeeranitabened daeatias 15 5 3 2 Pin 0 t and Cable type ida das 15 5 3 3 Termination plisadas 16 5 3 4 Control DUS eC UO e a nc 16 5 3 5 Maximum distance between NCB deviCesS ccccoooccnccccnncnncncnncononononcnonononcnnnnnnanons 16 6 GPI OM VOCE INS ose enti tassel tcl Sultanate 17 7 Control Panel operation td 18 Pel Button descriptio it a a 18 TALA TOJI td di td 18 FA Panel Enable td e da td bs a ne bh do 19 Flia Take 0 Oi a tallas 19 TAE CAME A E II A da A ee E O E 19 O irs Sec re cect est ah ec oe ec ea le eee ee oe i chee a ego ad 19 TIO MPa sas 19 AS A A A E aa Sets 19 vn RR 20 PNP OM OCK rl rd e A A le o Ae E 20 FAAAOAO td tt rta 20 General environmental requirements for Nevion equipment ccccccccccccnnnnno 21 Product Warranty nostra 22 nevion com 3 VikinX Sublime Control Panels Rev 11 Important notes regarding Software in the VikinX Sublime router family range 23 Appendix A Materials declaration and recycling information 00ceeee 24 Az Materials declarations voca ii tae 24 A 2 Recycling MO Male cdi dad caesar 24 EC Declaration of Conformity s 00 ia 25 nevion com 4 VikinX Sublime Control Panels Rev 11 1 Product overview Nevion are proud to present the 2nd generation of the compact small and medium routing switcher family Sublime With Sublime Nevion now provide a stable and proven product line incl
15. e both Ethernet LEDs will be blinking After the start up sequence the LEDs will indicate the Ethernet state 4 2 Alarm states The LED can either be red R green G yellow Y or have no light N The LED state is here described with twenty letters each representing 100ms which totals to an alarm sequence of two seconds The X indicates that the LED keeps the color it has the moment the alarm sequence begins green yellow or no light Description LED state Alarm Comment Continuous GGGGG GGGGG GGGGG No alarm green light GGGGG Status is OK Continuous YYYYY YYYYY YYYYY YYYYY Unable to This alarm will be yellow light connect to overwritten by other controller alarms over Ethernet Long red RRRRR NNNNN RRRRR Power is too blinks NNNNN low One short RXXXX XXXXX XXXXX XXXXX Power A Only active if power red blink failed alarm dip is set Two short XXXXX XXXXX RXRXX XXXXX Power B Only active if power red blinks failed alarm dip is set Red with one YRRRR RRRRR RRRRR No valid short yellow RRRRR product key blink 4 3 Ethernet states The LEDs that are located at the Ethernet bus will after the Start up sequence indicate the Ethernet states On Off Blinking Green Valid link No link Yellow No data Data is transmitted or received nevion com 12 VikinX Sublime Control Panels Rev 11 5 Router communication You gain access to router for communication pur
16. e it is not possible to return the product to Nevion or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labeled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circuit boards may contain battery backed memory device nevion com 24 mevion X Sublime Control Panels Rev 11 EC Declaration of Conformity MANUFACTURER AUTHORIZED REPRESENTATIVE Established within the EEA MODEL NUMBER S DESCRIPTION DIRECTIVES this equipment complies with HARMONISED STANDARDS applied in order to verify compliance with Directive s TEST REPORTS ISSUED BY TECHNICAL CONSTRUCTION FILE NO YEAR WHICH THE CE MARK WAS AFFIXED TEST AUTHORIZED SIGNATORY MANUFACTURER 2 Y Mi WENION Fr oot WA 0 9165 Name Thomas Vhrbom Position VP of Business Support Systems Nevion authorized signature Nevion Europe AS P O Box 1020 3204 Sandefjord Norway Not applicable SL 8XY CP SL 32S CP SL 8S CP SL 32S CP GPI SL 8S CP GPI SL 32XY CP SL 16XY CP SL 64S CP SL 16D CP SL 64S CP GPI SL 16S CP SL 64XY XP SL 16S CP GPI Control Panels in the VikinX Sublime series Low voltage EU Directive 2006 95 EC EMC EU Directive 2004 108 EC RoHS EU Directive 2002 95 EC China RoHS
17. ease modes relates to how the user operates the joystick on a Camera Control Unit When the operator pushes down on the joystick there will be a contact closure on the GPI out of the CCU and when the user releases the joystick the contact opens Normally multiple CCUs will be connected to individual GPI inputs on the Sublime CP Release before switch Used in both GPI and Joystick mode The activation of a new input line will have no effect until the previous line is released If more lines are activated in sequence the latest activated one will result in a switching as soon as the previously active is released l e only one GPI will be active at a time i e the first CCU with a contact closure wins No other GPI can be triggered before the first CCU releases the contact closure Switch before release Used in both GPI and Joystick mode The activation of a new input line will generate a switching regardless of how many other lines that are already set l e multiple GPIs can be active at the same time The priority can be switched according to the following pattern SW 6 Joystick priority OFF Switch before release ON Release before switch Default mode is Switch before release 3 4 Power alarm The power alarm can be switched according to the following pattern SW 7 Power alarm OFF Disables Power Alarm ON Enables Power Alarm Default setting is Power alarm disabled
18. els are completely configurable with the System Configurator which is downloadable from the Support pages at http www nevion com All local control panels are given a default configuration which includes the buttons A V Toggle Panel Enable Take on off and Take In addition input and output buttons are preconfigured The extra buttons on the 2RU and 4RU panels are not preconfigured They may be configured by the user Note that GPI functions are not programmable on Sublime GPI CP s They have a fixed preconfigured function described earlier in Chapter 3 7 1 Button description 7 1 1 A V Toggle The A V Toggle button enables disables audio and video on a specified address The address can either be read from the dip switches or be fixed The button toggles between three states The user may program more than one A V Toggle buttons one button for each router level that the user wants to control See Chapter 5 2 1 and the Nevion Configurator User Manual for further details If the button is pressed for more than 1 second it will go into a fourth state where both audio and video are disabled In this state the button will be dimmed If the button is pressed for more than 1 second again it will enable both audio and video if present Button Color Video Enabled Audio Enabled Yellow Yes Yes Green Yes No Red No Yes Dimmed No No If neither audio nor
19. h 2 additional programmable buttons on the bottom left side These buttons may be programmed in the same way as any of the other programmable buttons Sublime 4RU Control Panels come with 6 additional programmable buttons on the bottom left side These buttons may be programmed in the same way as any of the other programmable buttons nevion com 5 VikinX Sublime Control Panels 2 Specifications 2 1 Mechanics Dimensions Safety Emission standards Rev 11 HxWxD 44x483x50mm 19 1RU HxWxD 88x483x50mm 19 2RU HxWxD 176x483x50mm 19 4RU Compliant with CE EN55103 1 and 2 2 1 1 Weight and power consumption Device SL 8XY CP SL 8S CP SL 8S CP GPI SL 16XY CP SL 16D CP SL 16S CP SL 16S CP GPI SL 32XY CP SL 32S CP SL 32S CP GPI SL 64XY CP SL 64S CP SL 64S CP GPI SL PWR 40 PSU 2 2 Power Supply SL PWR 40 AC Supply voltage range AC Mains connector DC output DC connector Status monitoring Safety standards 2 3 Control Standard Features Serial port Connector NCB ports Connectors 2 Ethernet port Connector Weight incl 1x Current Current 15V Power PSU 15V 1 0 kg 300 mA 3 mA 5 W 1 0 kg 300 mA 3 mA 5 W 1 2 kg 400 mA 3 mA 6 W 1 0 kg 300 mA 3 mA 5W 1 0 kg 300 mA 3 mA 5W 1 0 kg 250 mA 3 mA 4 W 1 2 kg 400 mA 3 mA 6 W 1 4 kg 300 mA 3 mA 5W 1 0 kg 300 mA 3 mA 5W 1 3 kg 400 mA 3 mA 6 W 2 1 kg 300 mA 3 mA 5W 1 4 kg 300 mA 3 mA 5W 1 6 kg 400 mA 3 mA
20. is protected before pressing the button it will become unprotected If not the active output on all enabled levels will be protected A protected output can t be switched by anyone else but the user that protected it nevion com 20 VikinX Sublime Control Panels Rev 11 General environmental requirements for Nevion equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature 0 C to 45 C range Operating relative humidity range lt 95 non condensing 2 The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 55 C Relative humidity range lt 95 non condensing nevion com 21 VikinX Sublime Control Panels Rev 11 Product Warranty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Nevion which are available on the company web site www nevion com nevion com 22 VikinX Sublime Control Panels Rev 11 Important notes regarding Software in the VikinX Sublime router family range This product utilizes software components that are licensed with open source licenses The source code for these components and our modifications are available from http abs nevion com open source OpenTCP includes software developed by Viola systems http Awww violasystems com nevion com 23 VikinX S
21. n about the above described configuration connection options It is NOT possible to connect more than 2x Sublimes with HW rev 1 together via Ethernet unless a Multicon is applied as system controller 5 3 NCB connection Via the Network Control Bus system several routers and control panels can be interconnected Up to 16 levels of routers or combinations of routers can be controlled The NCB system and all RS 232 ports interchange the system status This means that any control system either from Nevion or from a third party manufacturer connected to any RS 232 port in the NCB loop will have access to all communication data on the bus 5 3 1 Connecting control panels To get a control panel working with a specific router configure the control panel to the same level as the router Several panels can be configured to control the same router Panels can also be connected to a router via the RS 232 interface Please refer to your control panel manual for installation 5 3 2 Pin out and cable type VikinX Sublime routers and Control Panels use RJ45 connectors for the Network Control Bus ports The following pin out is used Pin 1 Not Connected Pin 2 Not Connected e E Pin 3 Data retour 15 Pin 4 Data Green Blue aos Pin 5 Data BEN TE Pin 6 Data retour Orange 12 a Pin 7 Not Connected Pair A Pin 8 Not Connected t The following connection example shows connection of 4 VikinX devices with RJ45 connector
22. oller the limitations that apply are 1 One Sublime control panel may connect to a maximum of 4 Sublime routers 2 One Sublime router may be controlled by a maximum of 4 Sublime control panels Exceptions to the above limitations A router with a local CP e g SL V6464 CP may only connect to 1 other router Both routers must be configured with the same address and be of different type A V Example 1x SL V6464 CP may only control itself 1x Audio router AA or AES Both routers must be configured with the same address 16x2 routers that are expanded to NNx2 are using the NCB bus for this purpose The total NNx2 router is therefore counted as 1 router in the limitations 1 and 2 above From limitations 1 and 2 above the resulting Ethernet configuration may consist of maximum 8 devices 4 routers and 4 control panels with the exceptions mentioned above An example is illustrated in the figure below System Configurator Physical connections Control lines Ethernet lines 4 YY IO SE C z l LOM ae sd NE trail iR a En A ne N 44 Abs xD 7 wy FY if N port o Ethemet DAME Sad LAN i Switch f PA A y E E SS 8 nt E A EN Y SL router AG 4x64 x dy SL router SL router ADG2x32 ADG2032 sa TAIA Figure 3 Ethernet connections and configuration nevion com 14 VikinX Sublime Control Panels Rev 11 Refer to the System Configurator User Manual for further informatio
23. our PC It is NOT possible to select protocol options on Sublimes with HW rev 1 Use your System Configurator to verify the HW revision of your Sublime unit nevion com 10 VikinX Sublime Control Panels Rev 11 D Untitled project System Configurator Network Electronics ASA File View Tools Windows Help car G ed Chose 2 Refresh IP Settings Levels H Vitual Router Mappings 33 Categories _ Salvos Button Configurations Project Explorer Name a Info Controllers Status Hostname IP address Subnet mask Default gateway TCP connections Sublime type Firmware Bootloader HW revision MAC address E ES 5 CAASL_16D_CP 10 10 13 100 255 255 240 0 10 10 10 254 CAA_ETHCON CP DIP 2 104 00 0D 39 0A 00 64 i cota CAA_SL_AD3232_CP 10 10 13 101 255 255 240 0 10 10 10 254 None a 32x32 aes router CP CP DIP 15 202 20 1prel 00 00 39 00 00 00 ACA SSCP sui CAA_SL_SD1602_CP 10 10 13 102 255 255 240 0 10 10 10 254 None vs 64x16 video router CP DIP 10 104 00 00 39 FE 01 14 ime Ie Sia 16XY CP_ 10 10 148 255 255 240 0 10 10 10 254 JGS_ETHCON CP DIP 14 105 00 0D 39 FF 00 1F E C_ Sublime JGS_SL8XY CP 10 10 14 255 255 240 0 10 10 10 254 JGS_ETHCON CP DIP 14 105 00 00 39 FF 00 22 E Sublime JGS_SL D32P_rev2 10 10 14 12 255 255 240 0 10 10 10 254 None wus 32 ports data router DIP 13 203 20 1prel 00 00 38 FF 00 2E
24. poses by connecting either the router s serial port to your computer or by using an Ethernet connection Do not use both the router s Ethernet port and RS 232 serial port or NCB ports at the same time Doing so may cause loss of important communication and control data 5 1 Serial connection Connection can be made through the serial port of the router see also Chapter 0 for connection details The communication parameters are configurable Please refer to the protocol documentation of the appropriate communication control protocol Example The protocol parameters of the VikinX Compact routers are as follows Bit rate 19200 bit s Data bits 8 bits Stop bits 1 Parity No parity For further details concerning this protocol please refer to the following manual NCB Protocol paf The DE9 female socket for the serial port of the router has the following pin out Pin RS 232 mode Not in use Tx Rx Not in use GND GND RTS CTS Do Not Connect Note that if the standard RS 232 cable specification DCE is followed OO NI Od 01 AOIN A cable with Male Male or Female Female connectors at the cable ends is used for Rx Tx crossed connection and A cable with Male Female connectors at the cable ends is used for a straight through connection 5 1 1 Maximum cable length RS 232 IEEE has specified the maximum cable length for an RS 232 connection to
25. s and bus termination Figure 4 NCB loop configuration Note that each device at the end of the chain has a termination plug indicated with the letter T This termination plug must be inserted in the correct connection port If not no NCB communication is possible nevion com 15 VikinX Sublime Control Panels Rev 11 5 3 3 Termination plug The termination plug that is mentioned in the previous chapter is necessary when you want to avoid closing the loop be a long cable The termination plug is a standard RJ45 plug with the following internal wiring TMT 8 1 Figure 5 NCB loop termination plug As seen in the figure above Pin 3 is connected to Pin 4 and Pin 5 is connected to Pin 6 5 3 4 Control bus structure The Network Control Bus structure follows the standard MIDI bus definition The NCB is defined as a closed chain of units This means that the NCB OUT of the last unit must be connected to the NCB IN of the first unit in the NCB chain To avoid problems with the control of VikinX units the installer user has to assure that the bus structure is installed according to this definition The total number of VikinX devices in an NCB chain is limited to 50 5 3 5 Maximum distance between NCB devices The standard MIDI definition allows a maximum cable length of 200 250 meters between two devices Longer distances can be made with MIDI repeater units To avoid grounding problems all NCB ports
26. st status from the flash memory Activating a GPI I O will not influence the Take on off function nor will a Take on off function influence the activation of a GPI I O function 7 1 4 Take The Take buttons LED is normally off If the Take on off button is set to on no commands will be sent from the panel until the Take button is pressed The last selected buttons and the take button will blink until the Take button is pressed and the command is sent from the panel Activating a GPI I O will not influence the Take function nor will a Take function influence the activation of a GPI I O function 7 1 5 Output An Output button is used for selecting an output Selecting an output activates it so that it is switched to the next input that is selected 7 1 6 Input An Input button switches the active output to the selected input If the Take button is enabled the switch will not be executed until the Take button is pressed When switching using the Input button all enabled audio and video levels will be switched from the selected input to the active output Note that unlike the buttons on the front of the panel GPI inputs 1 32 cannot be reconfigured to represent other inputs i e they are fixed inputs 1 32 operating on the selected output 7 1 7 XY An Input to Output XY button switches a preset input to a preset output on all enabled audio and video levels If the Take button is enabled the switch will
27. ublime Control Panels Rev 11 Appendix A Materials declaration and recycling information A 1 Materials declaration For product sold into China after 1st March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the required information Toxic or hazardous substances and elements REW i R T ACHR SRK SRM Part Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium biphenyls diphenyl ethers Cr VI PBB PBDE All products referred to in O O O O O O Chapter 1 1 SL PWR 40 O O O O O O O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T1 1363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 Parts without any of the above mentioned hazardous substances are indicated by the product marking A 2 Recycling information Nevion provides assistance to customers and recyclers through our web site http www nevion com Please contact Nevion s Customer Support for assistance with recycling if this site does not show the information you require Wher
28. uding the most complete signal format and size offering available With the new ultra slim multi format and flexible product range Sublime fulfills the most demanding requirements from the professional broadcast market VikinX Sublime provides many of the powerful control features that drove the VikinX Modular range to success VikinX Sublime is ideal for general purpose facilities on air routing mobile outside broadcast applications and sophisticated A V applications This user manual presents the features installation and operation procedures of the control panels of the Sublime range 1 1 Product versions The following versions of the VikinX Sublime Control Panels are available Control Panels 19 1RU SL 8XY CP Multi bus X Y 8x8 panel SL 8S CP Single bus 8x1 panel SL 8S CP GPI Single bus 8x1 panel with GPI Joystick Tally interface SL 16XY CP Multi bus X Y 16x16 panel SL 16D CP Dual bus 16x2 panel SL 16S CP Single bus 16x1 panel SL 16S CP GPI Single bus 16x1 panel with GPI Joystick Tally interface SL 32S CP Single bus 32x1 panel SL 32S CP GPI Single bus 32x1 panel with GPI Joystick Tally interface Control Panels 19 2RU SL 32XY CP Multi bus X Y 32x32 panel SL 64S CP Single bus 64x1 panel SL 64S CP GPI Single bus 64x1 panel with GPI Joystick Tally interface Control Panels 19 4RU SL 64XY CP Multi bus X Y 64x64 panel 1 Sublime 2RU Control Panels come wit

Download Pdf Manuals

image

Related Search

Related Contents

Manual - O Z-wave  Dicota Hard cover Pro  - Trisak Co.,Ltd  ABB component drives ACS150 0.37 to 4 kW / 0.5 to 5 hp Catalog  User Manual - ALCATEL ONETOUCH  Page 1 Page 2 Page 3 Page 4 Page 5 8 ディスプレイ 9 ディスプレイ  manual de instalação  Mode d`emploi pour remplir le cahier des charges  取扱説明書 高圧フロアタッカ AT450H  EDUCATIONAL PC OSCILLOSCOPE KIT EDU09  