Home

CS+ for CC V3.00.00 Release Note

image

Contents

1. for CC V3 00 00 Release Note Chapter 6 Restrictions This section describes restrictions on CS 6 1 Restrictions imposed by debugging tools The abbreviations listed below collectively denote the corresponding tools in this section OCD serial E1 Emulator serial E20 Emulator serial OCD JTAG E1 Emulator JTAG E20 Emulator JTAG 6 1 1 List of restrictions imposed by debugging tools Target tool Target device Description Remarks OCD serial OCD JTAG Restriction on ID code authentication due to an error 6 1 2 Details of restrictions imposed by debugging tools No 1 Condition leading to errors in ID code authentication Applies to OCD serial and OCD JTAG for RX64M Description When both of the following conditions are met an error will occur in ID code authentication making it impossible to continue with debugging Conditions 1 A device having an ID code setting other than all FF is being debugged in user boot mode 2 After downloading a program that includes data for the option setting memory the CPU is reset by a RESET command RES pin reset or an internal reset Workaround There is no workaround R20UT3159EJ0100 Rev 1 00 ztENESAS Page 18 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note Chapter 7 Changes to the User s Manuals This section describes changes to the user s manuals for CS 7 1 Changes to the description of hook processes This section describes change
2. function RAM monitor pseudo RRM function after caution Before change non After change In order to use dynamic analysis using the RRM function RAM monitor pseudo RRM function it is necessary to set up the property of the debug tool Below the list of each debug tool and properties to be set up is shown Debug tool Properties Description RH850 Debug Tool Settings tab gt Select Yes Simulator Access Memory While Running category gt RX Access during the execution property Simulator Debug Tool Settings tab gt Specify the interval between 100 and Access Memory While Running category gt 65500 Display update interval ms property RH850 Debug Tool Settings tab gt Select Yes Full spec Emulator Access Memory While Running category gt E1 E20 Access during the execution property RX Debug Tool Settings tab gt Select Yes E1 EZ Emulator Access Memory While Running category gt Update display during the execution property Debug Tool Settings tab gt Specify the interval between 100 and Access Memory While Running category gt 65500 Display update interval ms property Debug Tool Settings tab gt Select Real time RAM monitor Trace category gt Usage of trace function property Debug Tool Settings tab gt Select Yes Access Memory While Running category gt Enable the automatic update of realtime displa
3. CS V3 00 00 RH850 Debug Tool R20UT3082EJ0100 CS V3 00 00 RX Debug Tool R20UT3083EJ0100 R20UT3159EJ0100 Rev 1 00 ztENESAS Aug 22 2014 Release Note Page 3 of 22 CS for CC V3 00 00 Release Note Chapter 3 Keywords When Uninstalling the Product There are two ways to uninstall this product e Use the integrated uninstaller from Renesas uninstalls all CS components e Use the Windows uninstaller only uninstalls this product To use the Windows uninstaller select the following from the Control Panel e Programs and Features Then select CS for CC R20UT3159EJ0100 Rev 1 00 ztENESAS Page 4 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note Chapter 4 Changes This chapter describes changes from V2 02 01 to V3 00 00 4 1 Improvement of CS functionality 4 1 1 Change of the name CubeSuite has been changed to CS from this version The expression of CubeSuite may remain in some documents but this should be read as CS 4 1 2 Multiple startup menus Startup from the Start menu of Windows is divided into two types e CS for CC RX RH850 e CS for CA CX 78K RL78 V850 Use either of the above startup menus according to the compiler in use Family Compiler Start Menu of Windows RX CC RX CS for CC RX RH850 RH850 CC RH CS for CC RX RH850 78K 78KOR CA78KOR CS for CA CX 78K RL78 V850 78KO CA78KO0 CS for CA CX 78K RL78 V850 RL78 CA78KOR CS for CA
4. R1 REG R2 REG struct Sample Lm_a 0x00000000 R1 REG long Lm_b s R1 REG R2 REG struct Base L m base 0x00000000 R2 REG long 5 3 14 Casting variables Applies to All debugging tools for RX When a variable is cast to another type in the Watch panel casting of the variable is C style For this reason the result of casting a class using virtual inheritance to its base class is not the same as the result of the cast within the program class AAA int m_aaa objA class BBB public AAA BBB inherits AAA int m_bbb objB class CCC CCC does not inherit AAA int m_ccc objC class AAA pa objA class BBB pb objB class CCC pc objC AAA pa Usable BBB pb Usable AAA pb Usable CCC pc Usable AAA pc Not usable because pc is considered to point to the top address of AAA Image of the cast in a program AAA void pc 5 3 15 PC entering the sleep state Applies to OCD JTAG and OCD serial for RX When a PC running Windows Vista or Windows 7 enters the sleep state debugging by CS cannot be continued after the PC reawakes Please set up the PC so that it does not enter the sleep state 5 3 16 Stopping and restarting tracing during program execution Applies to All debugging tools for RX When trace start events and end events have been set stopping and restarting tracing during program execution is not possible 5 3 17 Timestamps of trace information Applies to OCD JT
5. RX E1V EZ Emulator Debug Tool Settings tab gt Trace category gt Trace data type property Select Branch when acquiring only the function information Select Data Access when acquiring only the variable information Select Branch Data Access when acquiring the function information and the variable information The setup which can be selected is dependent on device Debug Tool Settings tab gt Trace category gt Usage of trace function property Select Trace Debug Tool Settings tab gt Trace category gt Trace data type property Select Branch when acquiring only the function information Select Data Access when acquiring only the variable information Select Branch Data Access when acquiring the function information and the variable information The setup which can be selected is dependent on device Debug Tool Settings tab gt Trace category gt Select trace size from the drop down list If Settings tab gt General category gt Enable dynamic analysis information property in Program Analyzer plugin is set as Yes the setting of the debug tool will be automatically changed at the time of connection R20UT3159EJ0100 Rev Aug 22 2014 1 00 RENESAS Page 20 of 22 CS for CC V3 00 00 Release Note 2 Change part 2 Location page 10 1 1 2 Types of analysis information 2 Dynamic analysis information b RRM
6. registered with the main project is opened gt Ifthe file is opened from either project only one file will be opened The smart edit function does not work correctly for a structure that does not have a name ifthe arguments of a function include a function call incorrect information will be displayed in the tooltip Names of member variables and functions are not correctly supplemented by the smart edit function in arrays of classes and of pointers to classes Supplementation does not produce appropriate strings even if a part of a member name is entered and ctrl space is also entered Outlining collapse expand only works with files that have been registered with the project Any files that have not been registered with the project will not be outlined in the Editor panel of CS e OnWindows 8 the display may become unclear due to anti aliasing n mixed display mode if a line number is specified for a jump the disassembled code is inserted and displayed so the specified line may not be displayed on the screen If a structure is nested the smart edit function does not work on the third and subsequent stages In addition information is not displayed in the tooltip For the first line of code immediately after ifdef endif the smart edit function does not show candidate members In addition no tooltip is displayed For the first variable in ifdef endif the smart edit fu
7. the same host machine but if you do so take note of the points listed below gt When two or more instances of CS are started the most recent information to have been written is saved in the information file for each user s own PC gt When two or more instances of CS are started the most recent information to have been written is saved in the information file for the stack analysis tools including CallWalker gt When the same project file is used in two or more instances of CS the most recent information to have been written is saved gt When the same project file is used in two or more instances of CS do not attempt building from more than one instance at the same time since the names of the output files will be identical 5 1 19 Options when starting CS Although the options below can be specified when starting CS W exe do not specify them If specified they will prevent the edit function from operating normally gt npall gt np to specify an editor 5 1 20 Mentions of R8C in user s manuals and online help R8C is mentioned in the user s manuals and online help but CS does not support the R8C family R20UT3159EJ0100 Rev 1 00 ztENESAS Page 12 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note 5 2 Points for caution regarding design tools 5 2 1 Changing packages If you change the package name in the pin layout properties the data input in the device top view and device pin list will be clea
8. 1 If you connect the emulator by using hot plug in the coverage measurement function is not available If you use hot plug in to connect the emulator please select No for Use code coverage measurement function in the Coverage category of the debugging tool properties 2 When the error message The system was reset is displayed during program execution coverage from the start of the program to the system reset will not have been measured 5 3 22 The break point setup in for statement or inline expanded function Applies to All debugging tools for RX If the following programs are described in C sauce the command of the source program is arranged at two or more addresses but the editor panel shows only one address When the break point is set up to this line the program stops only when the address that displayed on the editor panel is executed 1 Inline expanded function 1 2 template function 3 Head sentence of for statement or do while statement 1 Include the function that inline expansion was performed by optimization 5 3 23 The setting for DMAC DTC trace Applies to E20 emulator JTSG for RX64M When Bus Master of data access in the Trace category on the Property panel s Debug Tool Settings tab is set as DTAC DTC If External trace output in the Trace category is set as Trace output the trace function may not work correctly Please set as CPU execution or Do not output 5 3 24 Main clock source settin
9. 24 NE SAS CS for CC V3 00 00 R20UT3159EJ0100 Rev 1 00 Release Note Aug 22 2014 Chapter 1 Target Devices eet idit pected acca pesca e a Fa A ated eaten 2 Ghapter2 User s Manuals oec a Los e dead uU a ih Ede Oc RE ete 3 Chapter 3 Keywords When Uninstalling the Product essen 4 Chapter4 Changes ECT 5 Chapter 5 Points for Caution ssssssssssssssssseseseeennee nennen nennen arana aaa araea aaia 8 Chapter6 Restrictions eee rent exire pater xa irpa cde Giulia A e puta petu x dnx dotaiseiats 18 Chapter 7 Changes to the User s Manuals ssssssssssseeneeeeeene enne nennen nnne nennen 19 R20UT3159EJ0100 Rev 1 00 RENESAS Page 1 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note Chapter 1 Target Devices The target devices supported by the CS are listed on the Website Please see this URL CS Product Page http www renesas com cs R20UT3159EJ0100 Rev 1 00 RENESAS Page 2 of 22 Aug 22 2014 CS for CC V3 00 00 Chapter 2 User s Manuals Please read the following user s manuals along with this document Manual Name Document Number CS V3 00 00 Installer R20UT3094EJ0100 CS V3 00 00 Editor R20UT3096EJ0100 CS V3 00 00 Python Console R20UT3097EJ0100 CS V3 00 00 Updater R20UT3098EJ0100 CS V3 00 00 Message R20UT3099EJ0100 CS V3 00 00 Project Operation R20UT3101EJ0100 CubeSuite V2 02 00 Analysis R20UT2868EJ0100
10. 9510 Renesas Electronics Korea Co Ltd 12F 234 Teheran ro Gangnam Ku Seoul 135 920 Korea Tel 82 2 558 3737 Fax 82 2 558 5141 2014 Renesas Electronics Corporation and Renesas Solutions Corp Colophon 4 0
11. AG and OCD serial for RX The timestamps of trace information will not indicate the right times if the time between frames exceeds that corresponding to the trace counter 20 bits or when trace output is lost 5 3 18 Linkage options of CC RX Applies to All debugging tools for RX CC RX does not support the sdebug linkage option Please set Outputs debugging information in the output category of the Link Options tabbed page to debug 5 3 19 Return out command execution Applies to All debugging tools for RX Executing a return out command from a recursive function may lead to execution stopping at the address of the return instruction in the called function instead of the correct line in the calling function R20UT3159EJ0100 Rev 1 00 ztENESAS Page 15 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note 5 3 20 Startup program protection Applies to OCD serial for RX100 Executing a CPU reset after one of the following operations during the execution of a user program will lead to a discrepancy between the contents of ROM as displayed by the debugger and the contents of the actual ROM of the MCU In this case the contents will match after re executing then stopping the user program Calling the R_FCL_ChangeSwapFlag function to immediately swap boot areas Controlling the flash initial setting register FISR to immediately swap boot areas 5 3 21 Coverage measurement function Applies to E20 emulator JTAG for RX64M
12. CX 78K RL78 V850 V850 V850E CA850 CS for CA CX 78K RL78 V850 V850E2 CX CS for CA CX 78K RL78 V850 Note that when CS is started up by double clicking a project file the CS appropriate for the project type will be started up 4 1 3 Addition of a new facility to split panels Highlighting of the focused tab in split panels is now supported 4 1 4 Addition of the memory mapping profiler function The memory mapping profiler function is now supported 4 1 5 Improvement of the Option dialog box Build Debug is separated into Build and Debug The Enable parallel build between projects check box is added to Build 4 1 6 Improvement of the external tool startup function Placeholders that can be specified with startup options of an external tool are added Placeholder Name Description ActiveProjectDir Replacement with the absolute path of the active project folder ActiveProjectName Replacement with the active project name FileDir Replacement with the absolute path of the folder containing the file that is currently selected in the Project Tree panel MainProjectDir Replacement with the absolute path of the main project folder MainProjectName Replacement with the main project name MicomToolPath Replacement with the absolute path of the installation folder of this product ProjectDir Replacement with the absolute path of the project folder ProjectName Replac
13. Canada Limited 1101 Nicholson Road Newmarket Ontario L3Y 9C3 Canada Tel 1 905 898 5441 Fax 1 905 898 3220 Renesas Electronics Europe Limited Dukes Meadow Millboard Road Bourne End Buckinghamshire SL8 5FH U K Tel 44 1628 585 100 Fax 44 1628 585 900 Renesas Electronics Europe GmbH Arcadiastrasse 10 40472 D sseldorf Germany Tel 49 211 6503 0 Fax 49 211 6503 1327 Renesas Electronics China Co Ltd Room 1709 Quantum Plaza No 27 ZhiChunLu Haidian District Beijing 100191 P R China Tel 86 10 8235 1155 Fax 86 10 8235 7679 Renesas Electronics Shanghai Co Ltd TA Unit 301 Tower A Central Towers 555 Langao Road Putuo District Shanghai P R China 200333 Tel 86 21 2226 0888 Fax 86 21 2226 0999 Renesas Electronics Hong Kong Limited Unit 1601 1613 16 F Tower 2 Grand Century Place 193 Prince Edward Road West Mongkok Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2886 9022 9044 Renesas Electronics Taiwan Co Ltd 13F No 363 Fu Shing North Road Taipei 10543 Taiwan Tel 886 2 8175 9600 Fax 886 2 8175 9670 Renesas Electronics Singapore Pte Ltd g 80 Bendemeer Road Unit 406 02 Hyflux Innovation Centre Singapore 339949 Tel 65 6213 0200 Fax 65 6213 0300 Renesas Electronics Malaysia Sdn Bhd Unit 906 Block B Menara Amcorp Amcorp Trade Centre No 18 JIn Persiaran Barat 46050 Petaling Jaya Selangor Darul Ehsan Malaysia Tel 60 3 7955 9390 Fax 60 3 7955
14. High performance Embedded Workshop project to make it compatible with the CS succeeds but building of the project leads to an error when any of the following conditions is satisfied Placeholder TCINSTALL is used in the project TCINSTALL remains in the project even after conversion but the CS does not recognize TCINSTALL Placeholder TCINSTALL that has been used as a parameter for Options in the High performance Embedded Workshop is simply passed to the CS and may cause an unintended result e g an error upon building of the project For this reason you should manually change TCINSTALL after converting the project R20UT3159EJ0100 Rev 1 00 ztENESAS Page 10 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note gt Placeholder WORKSPDIR is used in the project If you select a HEW project file with extension hwp in the CS this is automatically converted to ProjectDir the directory above the project directory An error may occur during building of the project if the workspace does not exist in the directory indicated by 9oProjectDir96 For this reason you should manually change ProjectDir after converting the project gt A custom build phase is used in the project Since all custom phases are deleted upon conversion an error may occur during building of a project that involved a file output created for a custom build phase in the High performance Embedded Workshop After convert
15. a period Filenames cannot start with a plus sign or minus sign CS is not case sensitive to file names File names may have up to 259 characters including the path Do not use source files with the same file name Even if they are on different paths CS cannot classify them File names other than the above File names comply with Windows conventions Note that the following characters cannot be used in file names Varte File names cannot start or end with a period or space CS is not case sensitive to file names File names may have up to 259 characters including the path Folder names Folder names comply with Windows conventions Note that the characters below cannot be used in file names 5 1 2 Panel display If your hardware environment does not meet the recommended specifications for CS the Property panel may appear small and have scrambled contents If this happens move the Property panel outside the split panel area Enable Dockable and make it a docking panel Enable Floating and make it a floating panel 5 1 3 User Account Control UAC function Windows Vista Windows 7 If the UAC function is disabled on Windows Vista or Windows 7 then if a user without administrator privileges creates a project and no Device Dependence Information is installed installation of the Device Dependence Information will begin but the installation will fail If the UAC function is disabled create projects a
16. ally after normal loading of the project it will not be executed if there is no load module file 5 5 5 Forced termination The following actions while a script such as an infinite loop is running may lead to the results of function execution being in error because the actions forcibly terminate the execution of functions 1 Forcible termination by selecting Forcibly terminate from the context menu or pressing Ctrl D in the Python Console 2 Changing the active project in a project with multiple projects 5 5 6 Forced stopping Executing Abort from the context menu will forcibly stop an executing script or function but hook and callback functions that had not started at the time the Abort was executed will still be executed in order after that 5 5 7 Executing Python commands during building Do not issue Python commands while building is in progress 5 6 I O Header File Generation 5 6 1 A Function to set I O Header Generation options It is possible to set I O Header Generation option at the I O Header File Generation Options tab on the property panel of the build tool The following 2 settings are now possible e Update I O header file on build e Other additional options 5 6 2 Generating I O Header File It is possible to generate I O Header File when selecting Generate I O Header File on the context menu of the build tool node on the project tree R20UT3159EJ0100 Rev 1 00 ztENESAS Page 17 of 22 Aug 22 2014 CS
17. ategory gt want to measure coverage Coverage area of measurement propert If Settings tab gt General category gt Enable dynamic analysis information property in Program Analyzer plugin is set as Yes the setting of the debug tool will be automatically changed at the time of connection All trademarks and registered trademarks are the property of their respective owners R20UT3159EJ0100 Rev 1 00 ztENESAS Page 22 of 22 Aug 22 2014 Notice 1 Descriptions of circuits software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples You are fully responsible for the incorporation of these circuits software and information in the design of your equipment Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits software or information 2 Renesas Electronics has used reasonable care in preparing the information included in this document but Renesas Electronics does not warrant that such information is error free Renesas Electronics assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included herein 3 Renesas Electronics does not assume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of Renesas Elec
18. chip PROGRAM ROM or Debug the program re writing the on chip DATA FLASH was set as YES 4 3 3 Trusted memory function of RX64M series RX The Trusted memory function of RX64M series was supported 4 3 4 Improvement of Action Event RX RH850 The specification was changed so that variable expression could also set up blank in Printf event tab 4 3 5 Improvement of download RX RH850 The specification was changed so that the applicable address might be displayed when the error occurred R20UT3159EJ0100 Rev 1 00 RENESAS Page 6 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note 4 4 Improvement of functionality of Python Console 4 4 1 Addition of Python functions The following Python functions are added Function Name Functional Overview common Pythonlnitialize Initializes Python debugger ActionEvent Delete Deletes an action event debugger ActionEvent Disable Disables the action event settings debugger ActionEvent Enable Enables the action event settings debugger ActionEvent Get Refers to the action event results debugger ActionEvent Information Displays the action event information debugger ActionEvent Set Sets an action event debugger GetlORList Displays a list of IOR registers 4 4 2 Addition of Python classes The following Python classes are added Class Name Functional Overview ActionEventCondition Sets conditions for action events ActionEventlnfo Hol
19. ds information on action events ActionInfo Holds information on action event results IORInfo Holds information on IOR registers 4 4 3 Addition of Python properties The following Python properties are added Property Name Functional Overview common ExecutePath Refers to the absolute path of the folder for the exe file of the running CS build Compile Macro Sets or refers to definition macros which are compiler options of the active project build Version Refers to the version of the compiler package debugger ActionEvent GetLine Sets or refers to the number of action event results to be held debugger Option AccessStopExecution Sets or refers to an option of the debug tool debugger Option AfterTraceMemoryFull Sets or refers to an option of the debug tool R20UT3159EJ0100 Rev 1 00 ztENESAS Page 7 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note Chapter 5 Points for Caution This section describes points for caution regarding CS 5 1 Points for caution regarding CS general 5 1 1 File names The following rules apply to folder and file names Folder and file names Do not use folder or file names that cannot be created from Windows Explorer Source file names load module file names and project file names File names consist of the characters a z A Z 0 9 the period the underscore plus sign and minus sign File names cannot start or end with
20. ement with the project name TempbDir Replacement with the absolute path of the temporary folder WinDir Replacement with the absolute path of the Windows system folder R20UT3159EJ0100 Rev 1 00 RENESAS Page 5 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note 4 1 7 Change of the configuration of user s manuals and online help The configuration for user s manuals and online help is changed The main configuration is as follows Installer only user s manual and no online help Project Operation Peripheral Function Operation Pin View API Reference Editor Compiler Build Tool Operation Debug Tool Analysis Python Console Updater Message 4 2 Improvement of functionality of build tool 4 2 1 Addition of the parallel build function The parallel build function is now supported Usage of the parallel build function enables multiple CPU cores on the host machine to simultaneously execute compilation and thus reduce the build time This function can also perform parallel build between projects that is simultaneous build of multiple projects 4 3 Improvements to the debugging tool 4 3 1 Improvement of Debug Console Panel RX The font of Debug Console Panel was changed into the monospaced font 4 3 2 Improvement of Debug the program re writing the on chip FLASH RX The specification was changed so that the software break could not be set as on chip PROGRAM ROM and on chip DATA FLASH when Debug the program re writing the on
21. en a file name is input with an extension that is selected in the Save as type drop down list or with an extension that is registered with Windows When an automatically added extension is not as expected modify the name of the file by using for example Explorer 5 1 10Conversion from PM to CS projects CS cannot read CA850 projects made by PM V6 00 V6 10 V6 11 then the Build Mode has been newly added Handling by CS is as follows 1 When Debug Build or Release Build is specified information on the added Build Mode cannot be read 2 When the added Build Mode is specified it leads to an error Workaround Use V6 20 or a later version of PM to read the project save it then read the project into CS 5 1 11 Debugging tool settings during project appropriation When you create a project by appropriate settings from another project only the settings for the default debugging tool will be imported In the RX family however internal processing is common to the emulator and simulator so the settings are imported regardless of which debugging tool is selected 5 1 12 Online help If you close the online help while the Search tab is being displayed and you then open the online help again and display the Contents tab the Coding and Build sections may disappear If this happens close the online help while the Contents tab is being displayed and then open the online help again 5 1 13 Changing the target device during the proc
22. enter the low power consumption mode and the PC is placed at the address of the next instruction 5 89 3 Traces over desired intervals Applies to Simulator for all devices If you perform a trace from a trace start event until a trace end event the simulator will not include the trace end event in the results of the trace For this reason if you are using a simulator set the trace end event one line below the range for which you require display of the trace data 5 3 4 Adding sub projects Applies to Common to all debugging tools and devices If you add a sub project while a debugging tool is connected downloading and so on may fail Only add sub projects while the debugging tool is disconnected 5 3 5 Breakpoints and other settings becoming invalid Applies to Common to all debugging tools and devices If you use leading underscores to differentiate function or variable names the debugger may recognize them incorrectly and change the symbols or invalidate breakpoint settings This applies in cases such as when you have two functions one named _ reset and the other named reset 5 3 6 Two or more variables having the same name Applies to All debugging tools for RX When two or more variables are defined with the same name in unnamed name spaces of different source files the Watch panel only shows the information on the first variable to be found R20UT3159EJ0100 Rev 1 00 ztENESAS Page 13 of 22 Aug 22 2014 CS for CC V3 00 00 Relea
23. es nuclear reactor control systems military equipment etc You must check the quality grade of each Renesas Electronics product before using it in a particular application You may not use any Renesas Electronics product for any application for which itis not intended Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for which the product is not intended by Renesas Electronics 6 You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics especially with respect to the maximum rating operating supply voltage range movement power voltage range heat radiation characteristics installation and other product characteristics Renesas Electronics shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products beyond such specified ranges 7 Although Renesas Electronics endeavors to improve the quality and reliability of its products semiconductor products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions Further Renesas Electronics products are not subject to radiation resistance design Please be sure to implement safety measures to guard them against the possibility of physical injury and injury or damage caused by fire in the event of the failure of a Renesa
24. ess of converting a project When the target device is changed in the Project Convert Setting dialog box while it is open for conversion of a project created by using the High performance Embedded Workshop PM or an earlier version of CubeSuite the value chosen in Kind of project is returned to the default value top type in the combo box For example The setting for Kind of project changes to the default type for example Application when the device selection is changed 5 1 14 Converting High performance Embedded Workshop projects Attempting to load a High performance Embedded Workshop project into the CS under certain conditions may not be possible or may lead to an error during conversion or building of the project 1 Converting a High performance Embedded Workshop project to make it compatible with the CS fails when any of the following conditions is satisfied No toolchain from Renesas Electronics Corp is selected for the project gt The project contains no tps file for use in setting up the High performance Embedded Workshop environment the tps file is automatically created when the project is opened through the High performance Embedded Workshop To avoid this problem you should open the project through the High performance Embedded Workshop once before starting conversion The project contains multiple CFG files each of which is used to set up a realtime OS from Renesas Electronics Corp 2 Converting a
25. fore change non After change In order to use dynamic analysis using the trace function it is necessary to set up the property of the debug tool Below the list of each debug tool and properties to be set up is shown Debug tool Properties Description RH850 Debug Tool Settings tab gt Select Yes Simulator Trace category gt RX Use trace function property Simulator Debug Tool Settings tab gt Select trace size from the drop down Trace category gt list Trace memory size frames property RH850 Debug Tool Settings tab gt Select Branch PC when acquiring only Full spec Emulator Trace category gt the function information Select Data Access when acquiring R20UT3159EJ0100 Rev 1 00 ztENESAS Page 19 of 22 Aug 22 2014 CS for CC V3 00 00 Debug Tool Settings tab gt Trace category gt Trace memory size frames property Release Note only the variable information Select PC Data Access when acquiring the function information and the variable information Select trace size from the drop down list RH850 E1 E20 Debug Tool Settings tab gt Trace category gt Select trace data property Select Branch PC when acquiring only the function information Select Data Access when acquiring only the variable information Select PC Data Access when acquiring the function information and the variable information
26. fter logging in with administrator privileges 5 1 4 Command accelerators included in split panels categories Although accelerators are displayed in the command menus of split panels and categories pressing these key combinations shortcut keys will have no effect Use the mouse to select menu items 5 1 5 Problem with a Windows update program Your computer may suffer a blue screen error if you apply the KB2393802 patch published by Microsoft Corporation If this error occurs please apply the patch provided by your computer s manufacturer or another source R20UT3159EJ0100 Rev 1 00 RENESAS Page 8 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note 5 1 6 Renesas Electronics real time OS 5 1 If you use the real time operating system for the RX family provided by Renesas Electronics install CS in a folder and path where the names contain no parentheses If you install it under the 64 bit version of Windows it will be installed in the Program Files x86 folder by default and since the folder path includes parentheses this will produce an error Changing microcontrollers Note the following points for caution when changing the microcontroller The microcontroller can only be changed to another within the same family since this will correspond to the same build tool RH850 and RX When changing the microcontroller do so while the debugger is not connected Save the project before changing the microcontroller Informa
27. fter the project is loaded into CS You will need to change the build mode as required n The order of linkage of the assembly output files ritbl obj for an RTOS project will differ from that in the High performance Embedded Workshop 5 1 15 Creating new projects Applies to RX If a new project is created by selecting Empty Application CC RX under the environment for the RX building the project may lead to the following errors 2132 E Cannot find D specified in option rom 12132 E Cannot find D 1 specified in option rom L2132 E Cannot find D 2 specified in option rom If you encounter these errors change the setting of ROM to RAM mapped section on the Link Options sheet in CS R20UT3159EJ0100 Rev 1 00 ztENESAS Page 11 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note 5 1 16 Microsoft IME If you are using Microsoft Office IME 2010 which is included in Office 2010 from Microsoft Corporation CubeSute may output error E2000006 Since Microsoft Office IME 2010 may have caused this problem replace it with Microsoft s standard IME or install the KB2687611 module provided by Microsoft Corporation to fix Microsoft Office IME 2010 5 1 17 Tutorials The Code Generator Plug in Pin Configurator Plug in and Program Analyzer Plug in are used in tutorials Enable them through the Plug in Manager dialog box 5 1 18 Starting multiple instances of CS Two or more instances of CS can be started on
28. g when PLL is selected as clock source Applies to OCD JTAG OCD Serial RX64M Please set up the following when PLL is selected as clock source Set the Main clock source of the Clock category of the Connection settings tab of a debug tool property as EXTAL When EXTAL is selected as PLL clock source set the frequency of EXTAL to Main clock frequency When HOCO is selected as PLL clock source set the frequency of HOCO to Main clock frequency 5 4 Points for caution regarding analysis tools 5 4 l Analysis Chart panel The Execution Time Percentage Chart tabbed page of the Analysis Chart panel cannot be displayed E1 E20 for RH850 Variable Value Changing Chart tabbed page of the Analysis Chart panel does not support Analysis of trace data mode E1 E20 for RH850 When the emulator does not support the time tags of the internal trace the Analysis Chart panel cannot be used E1 E20 for RX When a simulator is specified as the debugging tool in a graph of transitions in values realtime sampling of IORsis not supported The results on an Execution Time Percentage Chart may not be exact This is because the counter for time lag measurement of the trace is small and may overflow Please check whether it has overflowed by checking the timestamp of the Trace panel E1 E20 for RX R20UT3159EJ0100 Rev 1 00 ztENESAS Page 16 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note 5 4 2 Function Li
29. ing the project register the custom build phase command with the CS as a command to be executed before or after each phase as required gt A custom placeholder is used in the project Custom placeholders are not converted because the CS does not recognize them Any custom placeholder that has been used as a parameter for Options in the High performance Embedded Workshop is simply passed to the CS and may cause an unintended result e g an error upon building of the project For this reason you should manually change the custom placeholders after converting the project 3 Other a FILEDIR is converted to FileDir Leaving FileDir as it is when the pathname is edited in the Path Edit dialog box will lead to the following error The specified path contains a non existent folder W0205012 Edit the pathnames and replace FileDir with another placeholder or directory name b WINDIR is converted to WinDir c The order in which folders are displayed in CS may differ from that in the High performance Embedded Workshop d If a High performance Embedded Workshop project for which downloaded files have been specified is loaded into CS CS will show these files as the second and subsequent items in the list of downloaded files for each debugging tool e The compiler option output src is converted to output obj default f If you load a library project that has been linked to the standard library into CS the l
30. inkage setting will be discarded this is indicated in the log information that is output as a result of loading the project g If Use an existing library file has been selected for the library generator in the High performance Embedded Workshop the setting is changed to Do not add a library file in CS For this reason linking with the specified library will not proceed this is indicated in the log information that is output as a result of loading the project h Option settings that were made on the Toolchain Option tabbed page of the High performance Embedded Workshop are not converted but discarded i e they are not moved across to CS i If a sub command file has been selected for the linkage editor in the High performance Embedded Workshop the Use external subcommand file setting is discarded when the project is loaded into CS The linkage editor options will have their default settings j Any files specified with the library input or binary option will not be listed in the Link Order dialog box The result is that the order of linkage for these files will not be selectable K RTOS configuration files will not be displayed under the Configuration file category node after the project is loaded into CS I RTOS option settings that were made in the High performance Embedded Workshop are discarded RTOS options will have their default settings in CS m The build mode for RTOS projects will be DefaultBuild a
31. licable export control laws and regulations and follow the procedures required by such laws and regulations 10 Itis the responsibility of the buyer or distributor of Renesas Electronics products who distributes disposes of or otherwise places the product with a third party to notify such third party in advance of the contents and conditions set forth in this document Renesas Electronics assumes no responsibility for any losses incurred by you or third parties as a result of unauthorized use of Renesas Electronics products 11 This document may not be reproduced or duplicated in any form in whole or in part without prior written consent of Renesas Electronics 12 Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas Electronics products or if you have any other inquiries Note 1 Renesas Electronics as used in this document means Renesas Electronics Corporation and also includes its majority owned subsidiaries Note 2 Renesas Electronics product s means any product developed or manufactured by or for Renesas Electronics 2 NE S AS SALES OFFICES Renesas Electronics Corporation http www renesas com Refer to http www renesas com for the latest and detailed information Renesas Electronics America Inc 2801 Scott Boulevard Santa Clara CA 95050 2549 U S A Tel 1 408 588 6000 Fax 1 408 588 6130 Renesas Electronics
32. nction does not show candidate members for the code after endif In addition no tooltip is displayed When a file not included in a project is opened a bookmark is set the project is closed the setting for the bookmark in the file is changed the project is opened again and the Bookmarks dialog box is opened the dialog box will display the bookmark with the setting when the project was closed while the source window displays the bookmark with the new setting that was made after the project was closed That is different settings are displayed for the bookmark in the dialog box and source window In such cases close the file and then open it again The display of the bookmark in the Bookmarks dialog box will then reflect the display in the source window When the rectangular selection tool obtained by holding the Alt key down and then using the R20UT3159EJ0100 Rev 1 00 RENESAS Page 9 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note mouse to select an area is used and the selected area is pasted to add lines in and after the last line the selected area is pasted from the beginning of the line after last regardless of the location specified for pasting Insert spaces after pasting as required When saving a file in the Save As dialog box the extension listed at the top of the Save as type drop down list is automatically added unless another extension is specified Note however that an extension is not added wh
33. pplies to All debugging tools for RX Changing the priority section among overlaid sections is not immediately reflected in debugger operations To update the display of addresses in the editor for example you need to close the file and open it again To update the display of variables in the Watch panel execute a single step of the program 5 3 12 Variables assigned to registers Applies to All debugging tools for RX When the selection for Scope in the Local Variables panel is not Current the values of variables assigned to registers are not displayed correctly Editing these values is also not possible 5 3 13 Locations to which variables are assigned Applies to All debugging tools for RX When a defined variable satisfies both of the conditions given below the Watch and Local Variables panels indicate the location of the entire variable rather than the location of its member variables Conditions 1 The variable is assigned to two or more addresses or registers i e two or more addresses or registers are displayed in the address column 2 A structure class array or union type member is defined in the variable Example struct Mem long m_base struct Sample long m_a struct Mem m b Condition 2 E R20UT3159EJ0100 Rev 1 00 ztENESAS Page 14 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note main struct Sample obj Display in the Watch and Local Variables panels obj
34. red 5 2 2 Saving projects If you save a project that has sub projects while the Device Top View or Device Pin List panel is open then the device top view and device pin list of the last sub project in the Project Tree will always appear 5 3 Points for caution regarding debugging tools The abbreviations listed below collectively denote the corresponding tools in this section OCD serial E1 Emulator serial E20 Emulator serial OCD JTAG E1 Emulator JTAG E20 Emulator JTAG 5 3 1 Adding sub projects Applies to All debugging tools common to all devices Disconnect the debugging tool before adding a sub project that handles a different device from the main project 5 3 2 Low power consumption modes Applies to All debugging tools for RX When a forced break occurs in a low power consumption mode e g sleep stop or standby or an instruction that makes the CPU enter a low power consumption mode is executed during stepped execution the behavior of the simulator and the emulator will differ as follows Emulator The forced break leads to release of the CPU from the low power consumption mode Furthermore the CPU will enter the low power consumption mode during stepped execution Simulator Transitions to low power consumption modes e g by a register setting are not supported Executing a WAIT instruction causes a break with the PC placed at the address of the next instruction During stepped execution the CPU does not
35. s Electronics product such as safety design for hardware and software including but not limited to redundancy fire control and malfunction prevention appropriate treatment for aging degradation or any other appropriate measures Because the evaluation of microcomputer software alone is very difficult please evaluate the safety of the final products or systems manufactured by you 8 Please contacta Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances including without limitation the EU RoHS Directive Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations 9 Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture use or sale is prohibited under any applicable domestic or foreign laws or regulations You should not use Renesas Electronics products or technology described in this document for any purpose relating to military applications or use by the military including but not limited to the development of weapons of mass destruction When exporting the Renesas Electronics products or technology described in this document you should comply with the app
36. s to the description of hook processes Hook processes are described in the Debugging editions You can configure a hook transaction in the Hook Transaction Settings tab on the Property panel Setting up a hook transaction provides a way of changing the values of I O registers and CPU registers by executing a Python script before downloading a load module or before running or after resetting the CPU This makes the following points realizable 1 In program development even if the setting program for the I O registers is incomplete debugging can proceed by setting the I O registers before running the program 2 You can increase the download speed by configuring the I O registers before downloading a program 3 Downloading to external RAM can be easily handled by setting up I O registers before downloading You can use the following commands in a Python script to be executed as a hook process of the debugger debugger Register GetValue debugger Register SetValue debugger Memory GetValue debugger Memory SetValue If you want to use other Python commands please use the Hook command in the Python console 7 2 Change to CubeSuite V2 02 00 Analysis This section describes a change to the CubeSuite V2 02 00 Analysis document number R20UT2868EJ01 00 7 2 1 The setting of Dynamic analysis 1 Change part 1 Location page 10 1 1 2 Types of analysis information 2 Dynamic analysis information a Trace function after remarks2 Be
37. se Note 5 3 7 Member variable pointers Applies to All debugging tools for RX After the member variable pointer mp1 defined in the program below is registered with the Watch and Local Variables panels the type of the pointer is indicated as int not int Foo class Foo int m1 int Foo mp1 amp Foo m1 5 3 8 Assigning unions to registers Applies to All debugging tools for RX When a union is assigned to a register it is assumed that the members of the union are assigned to the lower order bytes of the register For this reason the values of the members will be incorrect when displayed as big endian 5 3 9 Functions with the same name and char type parameters Applies to All debugging tools for RX When three functions with char type parameters are defined as shown below the address of Func signed char will not be displayed i e the address of Func char will be displayed instead void Func char void Func signed char void Func unsigned char 5 3 10 Char type one dimensional arrays Applies to All debugging tools for RX When a char type one dimensional array is assigned to multiple locations in registers or memory as shown below no character string will be displayed in the value column of the Watch or Local Variables panel even after the array array has been registered with the panel is displayed instead char array 5 ABCD 5 3 11 Changing the priority section among overlaid sections A
38. st and Variable List panels E1 E20 for RH850 The Function List panel does not support Execution Time Execution Time Percentage and Code Coverage The Variable List panel does not support Data Coverage 5 5 Points for caution regarding the Python Console 5 5 1 Japanese input The Japanese input facility cannot be activated from the Python Console To enter Japanese text write itin an external editor etc copy it and paste it into the console 5 5 2 Display of the prompt The Python Console prompt gt gt gt may be displayed more than once as in gt gt gt gt gt gt results may be displayed after the gt gt gt or the caret may appear without a preceding gt gt gt prompt Entering functions is still possible in these situations 5 5 3 Paths to folders and files IronPython recognizes the backslash character Y as a control character For example if a folder or file name starts with a t then the sequence t will be recognized as a tab character Please use r path name to avoid this Example r c test test py A forward slash can be used instead of a backslash 5 5 4 Executing scripts for projects that do not have load modules If a script is specified in the startup options for use with a project that does not have a load module file or if project file py is placed in the same folder as the project file then although the script would have been executed automatic
39. tion on pin layout design tool code generation design tool and debugging except for watch registration information are not carried over after the microcontroller has been changed 5 1 8 Plug in Manager function We recommend that the checkbox for the plug in for the microcontroller that is the target for development is not deselected on the Basic Function tabbed page of the Plug in Manager dialog box Deselect the checkboxes for the build tool and debugging tool plug ins that are for microcontrollers that are not the target for development For example if only the plug in for the build tool is deselected the file to be downloaded by the debugging tool will not be found and an error will occur 5 1 9 Editor panel The Page Setup dialog box is not available Although there is a Copy button on the Print Preview toolbar it does not work When a variable or label is selected and the Jump to Function feature is used from the context menu execution does not jump to the variable or label The Jump to Function feature will not jump to a static function defined in another file The following notes apply to the editor when source files with the same name but from different folders are registered with a main project and a sub project and load modules from both the main project and sub project are downloaded gt The address of the main project is displayed on the file gt At jumping to a source file from disassembled code the file
40. tronics products or technical information described in this document No license express implied or otherwise is granted hereby under any patents copyrights or other intellectual property rights of Renesas Electronics or others 4 You should not alter modify copy or otherwise misappropriate any Renesas Electronics product whether in whole or in part Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from such alteration modification copy or otherwise misappropriation of Renesas Electronics product 5 Renesas Electronics products are classified according to the following two quality grades Standard and High Quality The recommended applications for each Renesas Electronics product depends on the product s quality grade as indicated below Standard Computers office equipment communications equipment test and measurement equipment audio and visual equipment home electronic appliances machine tools personal electronic equipment and industrial robots etc High Quality Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems anti crime systems and safety equipment etc Renesas Electronics products are neither intended nor authorized for use in products or systems that may pose a direct threat to human life or bodily injury artificial life support devices or systems surgical implantations etc or may cause serious property damag
41. y property Debug Tool Settings tab gt Specify the interval between 100 and Access Memory While Running category gt 65500 Display update interval ms If Settings tab gt General category gt Enable dynamic analysis information property in Program Analyzer plugin is set as Yes the setting of the debug tool will be automatically changed at the time of connection R20UT3159EJ0100 Rev 1 00 ztENESAS Page 21 of 22 Aug 22 2014 CS for CC V3 00 00 Release Note 3 Change part 3 Location page 11 1 1 2 Types of analysis information 2 Dynamic analysis information c Coverage function after caution 3 Before change non After change In order to use dynamic analysis using the Coverage function it is necessary to set up the property of the debug tool Below the list of each debug tool and properties to be set up is shown Debug tool Properties Description RH850 Debug Tool Settings tab gt Select Yes Simulator Coverage category gt RX Use coverage function property Simulator RH850 The coverage function is not Full spec Emulator supported E1 E20 RX E1 EZ Emulator RX Debug Tool Settings tab gt Select Yes E20 Coverage category gt The device which is not supporting Use coverage function property the coverage function does not display this property Debug Tool Settings tab gt Specify the ranges where you Coverage c

Download Pdf Manuals

image

Related Search

Related Contents

Mode d`emploi  E-0242 Scientific Columbus/Rochester Inst. Syst 1988/04/20 R.G.  TBS GROUNDSTATION Manual  InfraCAM SD FR.indd  Westinghouse WHI-4CUPG User's Manual  dossier - Union des Maires de l`Oise  Striker Extreme  Teac DV W50E DVD  

Copyright © All rights reserved.
Failed to retrieve file