Home
        OneCommand Manager for VMware vCenter Release Notes
         Contents
1.    The OneCommand Manager for VMware vCenter does not load in the VMware web client  when IE 10 or later browsers are used     The OneCommand Manager for VMware vCenter User Manual   s Troubleshooting section  includes procedures to accept blocked content as a temporary remedy for certificate or  insecure content warnings for Internet Explorer  Chrome and Firefox  The Internet Explorer  procedure in the user manual is correct for IE9 or earlier browser versions  To accept blocked  content for IE10 and later browser versions  use the same procedure for Chrome and Firefox     a  Load the plug in URL in a separate tab or window  The plug in URL format is   https    lt plugin server gt   lt https port gt  elxveplugin  For example   https   pluginserverhostFQDN 443 elxvcplugin  Note  You can extract the plug in server  IP address  host name  and port number  from the browser warning message   b  Confirm or accept the certificate warning   c  Refresh the vSphere web client tab or window     Technical Tips    1     The Emulex VMware driver  Firmware and CIM Provider must be from the same release  as that of the OneCommand Manager for VMware vCenter  for the OneCommand  Manager for VMware vCenter to function properly    If the ESXi image  driver  or firmware is downloaded from the VMware website  use the  corresponding CIM Provider and OneCommand Manager for VMware vCenter from the  Emulex website  Also ensure that downloaded drivers  firmware  CIM Provider  and  OneCommand Manager f
2.  Professional Java Programming  ISBN  1 871003 82 X  by Brett Spell     OneCommand Manager for VMware vCenter Release Notes 7  P0010090 01A Rev  A    
3.  gt S EMULEX    OneCommand Manager for VMware vCenter  Release Notes    Version  10  2 348  20  Date  September 2014       Purpose and Contact Information    These release notes describe resolved known issues and current known issues associated with  this OneCommand Manager    for VMware vCenter release   For the latest product documentation  go to www Emulex com  If you have questions or require    additional information  contact an authorized Emulex   technical support representative at  tech support emulex com  800 854 7112  US Canada toll free    1 714 885 3402   US  International   or  44 1189 772929  Europe  Middle East  and Africa      New Features  e Supports up to four functions per port on 4 port OCe14000 series adapters  when  Alternate routing ID interpretation  ARI  is available    e Supports ExpressLane  also known as FOF priority queueing   e Supports iSCSI Boot firmware table  iBFT   e Supports Diagnostic port  D_Port  also known as ClearLink  for LPe16000 series adapters  e Supports Quality of Service  QoS  on LPe16000 series and OCe15000 series adapters    e Supports concurrent storage  iSCSI and Fibre Channel over Ethernet  FCoE   on an  OCe14000 series adapter port    Resolved Issues  1  Update firmware succeeds for an LPe11002 E adapter with the file zf282a4 all     Known Issues    1  Known Issues in regards to updating firmware     1  Firmware version 10 2 370 19 includes new features that required new flash regions to  support them  Firmware versions ea
4.  notice  this list of conditions and the following disclaimer    Redistribution in binary form must reproduce the above copyright notice  this list of conditions and the following disclaimer in the documentation  and or other materials provided with the distribution    Neither the name of Sun Microsystems  Inc  or the names of contributors may be used to endorse or promote products derived from this software  without specific prior written permission    This software is provided    AS IS     without a warranty of any kind  ALL EXPRESS OR IMPLIED CONDITIONS  REPRESENTATIONS AND  WARRANTIES  INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY  FITNESS FOR A PARTICULAR PURPOSE OR  NONINFRINGEMENT  ARE HEREBY EXCLUDED  SUN MICROSYSTEMS  INC      SUN     AND ITS LICENSORS SHALL NOT BE LIABLE FOR ANY  DAMAGES SUFFERED BY LICENSFE AS A RESULT OF USING  MODIFYING OR DISTRIBUTING THIS SOFTWARE OR ITS DERIVATIVES  IN NO  EVENT WILL SUN OR ITS LICENSORS BE LIABLE FOR ANY LOST REVENUE  PROFIT OR DATA  OR FOR DIRECT  INDIRECT  SPECIAL   CONSEQUENTIAL  INCIDENTAL OR PUNITIVE DAMAGES  HOWEVER CAUSED AND REGARDLESS OF THE THEORY OF LIABILITY   ARISING OUT OF THE USE OF OR INABILITY TO USE THIS SOFTWARE  EVEN IF SUN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH  DAMAGES     You acknowledge that this software is not designed  licensed or intended for use in the design  construction  operation or maintenance of any nuclear  facility     Copyright    2000 Apress Publishing Inc  All rights reserved  
5.  update     If you updated the firmware from a version earlier than 10 0 803 37  you must perform  the update process twice using a version 10 2 management application or firmware  update utility  You must reboot the system after each firmware update    2  Enabling or disabling boot on LPe16000 series adapters may show an error message   When enabling or disabling boot from the OneCommand Manager application GUI or CLI   an error message may be displayed    Workaround  The error message can be ignored  The boot state is changed even though the error message  is displayed   3  For LPe16000 series adapters  the OneCommand Manager for VMware vCenter CLI  firmwareupdate command does not work when  all  is specified    Workaround  To update firmware  do one of the following   e Use OneCommand Manager for VMware vCenter   e Individually specify the port WWN when using the OneCommand Manager for  VMware vCenter CLI firmwareupdate command   4  PFC  priority based flow control   active priority information is incorrect     OneCommand Manager for VMware vCenter shows incorrect information in the PFC  Properties area on the DCB tab  If the PFC Properties state is disabled  the Active Priority  field shows a value  It should show  N A      The OneCommand Manager for VMware vCenter CLI getpginfo and getdcbparams  commands also show a value for the PFC Priority field if the PFC State is disabled   Workaround   None     5  If Expresslane LUNs exist whose targets are no longer discovered  yo
6. From the Assigned Role list in the right pane  select a role with the required  privileges   Refer to the OneCommand Manager Application User Manual for the list of privileges    required  Refer to the OneCommand Manager for VMware vCenter Manual for more  information on role management     d  From the Users and Groups section on the left  click Add  The Assign Permissions  window is displayed     e  Onthe Assign Permissions window  select the user or the group to which the user  belongs and click Add     f  Click OK to exit the Assign Permissions window   g  Register OneCommand Manager for VMware vCenter     5  If the Emulex OneCommand tab in the vSphere console shows  Loading     or is blank     a  Right click and check whether the message    Movie not loaded    is present in the  context menu     b  If the message is present and you are using an IE browser  click Tools gt Internet  Options     c  Click the Advanced tab   d  From the Security list  clear the Do not save encrypted pages to disk checkbox   e  Restart the vSphere Console   6  To view online help using the Google Chrome browser  you must disable Chrome s  security check using the    allow file access from files  option     a  Create a copy of the Chrome shortcut on the desktop and rename it to RH Chrome  Local  or something similar      b  Right click on the new Chrome icon and select Properties    c  Add the text    allow file access from files  to the end of the path appearing in  Target  You must leave a spa
7. ce between the original string and the tag you are  adding    d  Click OK to save your settings    e  Close any open instances of Chrome    f  To open a local copy of the online help  use the new shortcut to open Chrome  press   lt Ctrl   Open gt   and browse to the start page  Alternatively  open Chrome with the  new shortcut  right click the start page and click Open With  gt  Google Chrome     OneCommand Manager for VMware vCenter Release Notes 6  P0010090 01A Rev  A     gt  lt  EMULEX          Copyright    2013 2014 Emulex  All rights reserved worldwide  This document refers to various companies and products by their trade names  In most   if not all cases  their respective companies claim these designations as trademarks or registered trademarks  This information is provided for reference  only  Although this information is believed to be accurate and reliable at the time of publication  Emulex assumes no responsibility for errors or  omissions  Emulex reserves the right to make changes or corrections without notice  This report is the property of Emulex and may not be duplicated  without permission from the Company     Note  References to OCe11100 series products also apply to OCe1100R series products     Copyright    2002 Sun Microsystems  Inc  All Rights Reserved  Redistribution and use in source and binary forms  with or without modification  are  permitted provided that the following conditions are met    Redistribution of source code must retain the above copyright
8. ion in the command line interface  using the    core    option  and specifying an FC world wide port name  WWPN  to indicate which adapter to dump   the command fails if the adapter is in a    down    state    Workaround   When specifying parameters for the dump command  always use the MAC address for one  of the NIC ports on the adapter    One or more hosts may not be discovered in the Cluster level view     Workaround  Ensure that the following conditions are met   e  CIM  Interaction  privilege is assigned to either the user or the user group     e No host in the cluster is in a  Not responding  state as shown in the VMware  inventory tree     If unresponsive hosts are present  corrective action should be taken to bring them  back to a stable state  or you must remove the unresponsive host from the inventory  before starting any operations in OneCommand Manager for VMware vCenter while  in the cluster view     Firmware update fails with MAL error when using on ESXi 5 1 inbox drivers     Workaround  Upgrade to the latest certified NIC driver     Link Up and Link Down events are not logged in Tasks Events tab in OneCommand  Manager for VMware vCenter     OneCommand Manager for VMware vCenter Release Notes 4  P0010090 01A Rev  A    19     20      gt  EMULEX    Workaround   Close the existing vSphere session window and reopen a new session  The Link Up and Link  Down events are updated    The DMA loopback test is supported only on the OneConnect adapters     Workaround   None 
9. or VMware vCenter are all from either Emulex branded pages or  from the same OEM specific download pages     The response time for OCM for VMware vCenter may be slow     To achieve the best performance  Emulex recommends that the system s  hosting the  OneCommand Manager for VMware vCenter be on the same network as the vCenter server  with a minimal number of network hops     For OneCommand Manager for VMware vCenter to support IPv6  the IPv6 protocol must  be installed  To enable the IPv6 protocol in a Windows Server machine    a  From the desktop  click Start gt Control Panel    b  Double click Network Connections  The Network Connections window is displayed     c  Right click any local area connection  then select Properties  The Local Area  Connection Properties window is displayed     OneCommand Manager for VMware vCenter Release Notes 5    P0010090 01A Rev  A     gt  EMULEX    d  Click Install  The Select Network Components window is displayed   e  Inthe Network Protocol list  select Protocol and click Add   f  Select Microsoft TCP IP version 6 and click OK   4  Registering the OneCommand Manager for VMware vCenter with the vCenter server fails  with the error    User has no privileges      The user is not listed in the Datacenter  Follow these steps to ensure the user has the required  privileges   a  Inthe vSphere console  select any parent node of the host or cluster in the inventory  tree and click the Permissions tab   b  Right click and select Add Permission   c  
10. rlier than 10 0 803 37 did not have the ability to  configure the flash regions to support these new features    If you are updating from a firmware version earlier than 10 0 803 37  use one of these  methods to update the firmware to 10 2 370 19     e Use the ISO flash tool     e Use the released 10 2 version of OneCommand for VMware vCenter  You must  perform the firmware update procedure twice to ensure that the flash regions are  properly configured  and you must reboot the system after each firmware update     OneCommand Manager for VMware vCenter Release Notes 1  P0010090 01A Rev  A     gt G EMULEX    Note  After you have updated the firmware  you must not downgrade the firmware to a  version earlier than 10 0 803 37     If you are updating from firmware version 10 0 803 37 or later  use one of these methods  to update the firmware to 10 2 370 19     e Use the ISO flash tool     e Use the released 10 2 version of OneCommand for VMware vCenter  and reboot the  system after the firmware update   It is not necessary to perform the firmware update  process twice      Note  After you have updated the firmware  you must not downgrade the firmware to a  version earlier than 10 0 803 37     2  If iBFT boot is non functional  and version 10 2 370 19 or later firmware is installed   you must update the firmware to version 10 2 370 19 using the ISO flash image or  using a version 10 2 management application or firmware update utility  You must  reboot the system after the firmware
11. s not support D_Port  the port remains in D_Port mode    Workaround   Manually reset the port    On the Channel Management tab  OneCommand Manager for VMware vCenter always  shows the permanent MAC address for each channel    Workaround    To correlate the permanent MAC address with the current MAC address  view the Port  Information tab  The Port Information tab always shows the current  user settable  MAC  address and the permanent MAC address     OneCommand Manager for VMware vCenter Release Notes 3  P0010090 01A Rev  A    12     13     14     15     16     17     18      gt G EMULEX    In Windows 7  using OneCommand Manager for VMware vCenter CLI audit commands  shows irrelevant error messages     For Windows 7  the C  disk is highly protected  even an administrator has limited privileges   For example  the contents in the    C  Program Files     directory have no write privileges or  full control privileges    Workaround   Do one of the following     e Assign your account write privileges and full control privileges to the    C  Program  Files      directory     e Install OneCommand Manager for VMware vCenter on another disk  such as D   For the iSCSI personality  the Target Portal tab is not available     Workaround  Use the OneCommand Manager for VMware vCenter client to login to iSCSI targets     For the NIC personality  IP attributes are not available     Workaround  None     Performing a dump command may fail if the WWPN is specified    When performing a dump operat
12. u may see  inconsistent behavior while configuring Expresslane for any newly discovered LUNs     OneCommand Manager for VMware vCenter Release Notes 2  P0010090 01A Rev  A    10     11      gt G EMULEX    Workaround  On the VMware host run the following command   esxcfg module  s    lpfc  and restart the cimserver with following commands    etc init d sfcbd watchdog stop   etc init d sfcbd watchdog start  On ESXi 5 5 hosts  running an external loopback test results in the following error     WBEMException  CIM ERR ACCESS DENIED  HTTP 401  Unauthorized   Error on  ESXi55 platform       Workaround   None    On ESXi 5 5 hosts  a loopback test fails intermittently  giving a general error after  approximately 3000 cycles    Workaround   None    For OCe14000 series adapters  on the Physical Port Info tab  the Set Speed button may be  grayed out    Workaround   None    For the LPe16000 series adapters  if an external loopback plug is connected to the system  a  D_Port test runs but does not stop running    This issue exists for OneCommand Manager for VMware vCenter GUI and the  OneCommand Manager for VMware vCenter CLI DportTest command    Workaround   Do not install an external loopback plug before running the D_Port test  The D_Port test can    only run if the port is connected to an appropriate switch     For the LPe16000 series adapters  if a diagnostic test  OQneCommand Manager for VMware  vCenter GUI or OneCommand Manager for VMware vCenter CLI  determines that the  switch doe
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
MANUEL D`UTILISATION Melangeur mmanuel Collomatic  S1000サーマルサイクラー 取扱説明書 - Bio-Rad  FXA2000-G User`s Manual  Electrolux EL7060A vacuum cleaner  BMR102 - Makita  Bedienungsanleitung Sony-Ericsson K200i  Scalasca User Guide - Forschungszentrum Jülich  UNIVERSIDAD DE ESPECIALIDADES  ADP15 Process Indicator / Controller Instruction Manual  Conditions générales d`achats    Copyright © All rights reserved. 