Conqueror User Manual

image

Contents

1. 2 I O x H Z o 4 ZONE PROGRAMMING STATUS LABEL JULY 2000 Pyronix W This product is approved for use in the Residential Commercial and Light Industrial Environment PYRONIX LIMITED ENGINEER NAME STATUS KEY ENTRY EXIT ACCESS 1 IMMEDIATE ENTRY EXIT TIME No SECS BELL OUTPUT SAB sce INSTALLATION DATE BELL TIME SERVICE DATE ACTION MINS PIR LEDs ENABLED SERVICE DATE DISABLED ACTION 9 8 SERVICE DATE nix ACTION OMITTED INSTALLATION COMPANY TEL ADDRESS CONTACT RLBLOQ8 Issue 3 RINS 049 155 1 e W Pyronix Pyronix Limited Pyronix House Braithwell Way Hellaby Rotherham S66 8QY ENGLAND Tel 44 0 1709 700100 Fax 44 0 1709 533429 Technical help line UK only 0900 8037 800 This isa premium rate line where calls are charged at 50p per minute email export sales pyronix com marketing pyronix com technical support pyronix com website www pyronix com WARRANTY This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a period of 2 years In the interest of continuing improvement of quality customer care and design Pyronix reserve the
2. PA PERSONAL ATTACK 6 EASY SET A UP ARROW FIRE DOWN ARROW 6 1 Full Setting the panel Enter either of the following Y X X User Code By using this method maximum volume of the entry exit tone will be heard or A e 0 By using this method no sounds will be emitted except for an acknowledge tone at the beginning and the end of the entry exit time 6 2 Part setting the panel Part set 1 eg downstairs only armed A mms NE A N qm JAN n 7 n e D or A e v both will give a silent setting Part set 2 eg upstairs only armed Enter R e 2 or e both will give a silent setting 6 3 Unsetting the panel The panel can be unset by entering the building via the entry exit route and then keying the user code 6 4 Activating the Personal Attack Alarm PA To activate the personal attack alarm enter 4 6 5 Activating the Fire Alarm To activate the Fire Alarm enter W 6 6 Turning Chime On and Off Panel must be in day mode Enter a D When the chime mode is selected a three note chime will be produced by the internal sounder and any extension speakers when an Entry Exit zone is activated The same key sequence can be used to turn off the chime facility 6 7 Recalling the Event Log The event log can now be displayed at any time when the Conqueror is unset The event log is displayed by pressing A The Day led will flash and event information from the latest alarm activation
3. is displayed Pressing any key will then show the previous event information When all the four have been displayed the day led will stop flashing and another function can be selected 6 8 Omitting one or more zones If one or more zones are triggered whilst in exit mode a low pitched error tone will be produced If any zones remain triggered at the end of the exit timer the error tone will continue Key in the User code The display will show the zone s which remained triggered Make a note of any triggered zones Key in the User code which will clear the display Check for any obvious reason for these zones to have been activated This may simply be due to a monitored door or window being left open or a pet being left in a protected area If the fault cannot be rectified it is possible to omit faulty zones but this should only be used as a last resort if the building is to be left unoccupied Example Set panel error tone will be heard Wait for the end of the exit timer Error tone is still being produced Key in the User code Triggered zones will be displayed Note triggered zones Key in User code to clear display then investigate fault s if possible Set panel again then Check the display if the zone s are not being triggered exit via normal route or If displays shows zones are as still being triggered then enter RO now enter the number of the zone to be omitted 1 to 4 then 2 Entry Exit timer will start again t
4. right to amend specifications without giving prior notice A copy of our warranty can be obtained from the above address RINS 049 ISSUE 2 15 14 CONTENTS 1 INTRODUCTION 2 FEATURES 3 FUNCTIONALDESCRIPTION 3 1 OPERATINGMODES 3 2 ENTRY EXITMODE 4 ZONES 4 1 ENGINEER PROGRAMMABLE ZONES 4 2 24HOURZONES 5 CONTROLS AND FUNCTIONS 6 USERFACILITIES 6 1 FULLSETTING THE PANEL 6 2 PART SETTING THE PANEL 6 3 UNSETTINGTHE PANEL 6 4 ACTIVATING THE PERSONAL ATTACK ALARM 6 5 ACTIVATING THE FIRE ALARM 6 6 TURNING CHIME ONAND OFF 6 7 RECALLING EVENT LOG 6 8 OMITTING ONE OR MORE ZONES 6 9 CLEARING THE EVENT LOG 6 10 CLEARING THE DISPLAY AFTER AN ACTIVATION 6 11 CHANGING THE USER CODE 6 12 SYSTEM TEST MODE 6 13 WALK TEST MODE 7 LEDFUNCTIONS TROUBLESHOOTING USERQUICK REFERENCE GUIDES RINS 049 ISSUE 2 gt C m 90 60 00 00 60 NI O Ug ds E c0 c 10 10 10 10 14 13 1 INTRODUCTION The Conqueror is full featured intruder alarm control panel based around a micro processor with 4 fully programmable zones and 2 dedicated 24 hour zones Personal Attack alarm and a System Tamper alarm It is operated via a 16 key onboard keypad and has an arrangement of 8 LEDs to show the status of the system All features are fully programmable and there are two levels of access to the system These are User amp Engineer The User level gives access to all setting and unsetting facilitie
5. ck buttons if necessary If the LED does not clear call the engineer O ZONE 4 TAMPER 6 RINS 049 issue 1 6 11 Changing User Code Ener 4 5 then X OX X User code 3 Bleeps then X X X Y New user code Bleeps then Y X X X New user code again Bleeps The DAY led will flash when this function is entered and an acknowledge tone will be sounded after each code has been entered If an incorrect key is entered an error tone will be given and the function ended 6 12 System Test Mode j Enter A 6 This function performs a number of tests which are listed below The next test is selected by pressing any numeric key To exit system test mode press the R key again 97 Test All LED s are switched on 1 2 The strobe is switched on 3 The bell is switched on 4 The internal sounder is switched on 6 13 Walk Test Mode Enter A D When the walk test mode is enabled any activated zone will cause a chime and the LED display to indicate To exit walk test mode press the Key again 7 LEDFUNCTIONS Supply light on Indicates there is mains on the system Day light on Indicates the system is unset Day mode Zone light on Indicates an Alarm activation Tamper light on Indicates a Tamper alarm P A light on Indicates a Personal Attack activation Tamper light flashing Engineer mode 10 5 CONTROLSANDFUNCTIONS Volume Control This is only accessible when the
6. e internal and external sounders will operate for the length of time programmed and the tone of the internal sounder will be two notes repeated rapidly The strobe lamp will also be activated and will 6 Mains Failure Panel unset Day mode continue to operate until the panel is reset Supply LED off indicating no mains supply to panel Check that there is mains supply else where on 6 Fullset Partset At the time of setting the control panel any one of three set modes can be selected i e the premises lf no supply in premises Went Fullset Whole system armed nobody on premises for mains power to return If there is mains Part set 1 Upstairs off Downstairs armed supply to the system contact the engineer Part set 2 Upstairs armed Downstairs off The above are purely examples The Engineer has the ability at the programming stage to configure all the circuits to the customer s exact requirements 3 2 Entry Exit Mode 7 Panel Waiting for Further Commands Day LED will flash if you have started a function but not finished the sequence Entry When the panel is set and an Entry Exit zone is triggered the Entry Exit timer will begin to count down During this period an Entry Exit tone single repeated bleep will be produced by the internal sounder and any zones which are programmed as Access zones will be ignored If the user code is entered before the end of the count down period the panel will return to day
7. front cover has been removed and will only affect the volume of the internal sounder together with any extension speakers The volume control is overridden when the panel is in an alarm state and also if the the panel has been set by the User code Chime Chime function applies to day mode only and if selected will cause the panel to generate a three note sound when an entry exit zone is triggered This feature is to inform the occupants of the building that someone has entered Latch The latch facility is designed to be used with intruder detectors fitted with a latch memory This feature is very useful when more than one detector has to be wired to a particularzone as it will show which detectors were triggered if an alarm occured If there has beenan alarm and latch memory was used then when the panel is reset an LED indication will be given at the relevant detector s Resetting of latch memory requires the panel to be set again for not less than 5 seconds and then unset Auto Rearm After an alarm the panel will automatically reset itself when the bell timer has expired Any zones which still remain triggered at that time will be omited automatically Walk test The walk test function verifys that all the intruder detectors on the alarm system are functioning correctly When the walk test mode is enabled any activated zone will cause a chime and the LED display to indicate RINS 049 issue 1 7 6 USER FACILITIES amp SHIFT 0
8. hen exit building by normal route 6 9 Clearing the Event Log The User if allowed by the Engineer can clear the log This is achieved by pressing N ee AG 6 10 Clearing the display after an activation After an alarm condition enter the User code 00000000 This unsets the panel The LEDs will display any activated zones Enter User code again This clears the display RINS 049 issue 1
9. mode If the timer is allowed to elapse before the user code is entered the panel will go into an alarm state In this case the system needs to be Unset SUPPLY Enter R to terminate 7 Exit With the panel in day mode if either the user code or an Easy set key sequence is entered the Entry Exit timer will begin If all the Immediate zones are clear then the Entry Exit tone will be heard Leave the protected area by the predetermined Entry Exit route As you trigger Access zones the tone will change temporarily to a repeated low tone When all the zones are clear the Entry Exit tone will continue again until the end of the time out period The panel will then be set RINS 049 issue 1 12 5 4 ZONES 8 TROUBLESHOOTING 4 1 Engineer Programmable Zones KEY O LEDOFF O ZONE 1 O ZONE 2 Entry Exit This is zone which allows limited time access to the premises in order to set or unset the system LEDON 1 LED FLASHING Access This is a zone which on setting the panel allows access to the Entry Exit zone However if the panel is set and an Access zone is triggered before an Entry Exit zone then an alarm will be generated immediately 1 Panel set on SUPPLY Immediate This is a zone which will when entered create an alarm when the panel is set 2 Panel unset off Omitted If a zone is programmed as an Omitted zone by the
10. pav Engineer then it is ignored by the panel Primarily used for Part set options It also allows the user to continue to use the alarm system even if a fault has been discovered 2 on one or more zones ZONE 1 ZONE 2 ZONE 3 FT ZONE 4 TAMPER 4 2 24 hour zones Personal Triggering of the Personal Attack P A zone will always be cause a Attack full alarm activation regardless of whether or not the panel is set 3 Panel unset Zone1 Zone 2 Zone Tamper A tamper zone activation will only generate an internal alarm if the panel is in Day mode If a tamper fault is Zone 4 LEDs on present and the panel is then set the system will give a second internal alarm Triggering of a tamper zone when This shows an alarm has occured the panel is set will always give an external as well as on Zones 1 to 4 Zone 2 was 3 internal alarm activated first To clear alarm lights enter User code If the LEDs do not Fire Triggering the fire zone will only operate the internal clear call engineer sounder A fire alarm is identified by a three note rising sound which is easily distinguished from all other tones Zone 4 may be configured as a fire zone The Fire Zone is intended as an extra feature to the Intruder Alarm system and must 4 Personal attack activated SUPPLY DAY zonei ZONE 1 not be regarded as a total fire protection system Enter User code to clear P A light Reset Personal Atta
11. s and also allows the changing of code numbers and testing of the system The Engineer level gives total access to the system including the ability to reconfigure the system The Engineer cannot however unset the system 2 FEATURES 2 Access Level Codes both programmable Easy set facility 4 Programmable alarm zones 3 Set Part Set modes Configurable fire zone with unique alarm sound Personal Attack alarm zone Tamper zone 16 key backlit keypad Dedicated Personal Attack key on keypad Dedicated Fire alarm key on keypad 8 LEDs for immediate indication of panel status Walk Test facility System Test Function Built in sounder with volume control and software override Separate Bell and Strobe lamp outputs Zone omit facility on exit Silent part set 4 Event extended memory NB your installation engineer will have programmed all the system features to ensure easy and convenient day to day use of your system see section Engineer Program mable Zones USER QUICK REFERENCE GUIDE b AES wer Nima 1 Unsetting Enter QUOC OO x Usercode Re enter QQ QO X X to clear LEDs 2 Fullset Enter XON or Silenton exit User code Full volume 3 Part set a Part set 1 Downstairs c e D b Part set 2 Upstairs e W or 2 NOTE Part sets are silent on exit Tones will be heard on entry 4 To activate the Personal Attack alarm enter e O 5 To activate
12. the Fire alarm enter AW 6 Zone omit in exit mode 7 Chime facility amp 1 8 Read Event Log 2 2 key to view next event 9 Clear Event Log 3 EN TS FS X QD 916 X Old User code 10 Changing User code Q 5 N i d AN XX VV X X New User code AENEA OX OUO X New User code 11 Enter System Test Mode 2 6 All LEDs switched on Press any The strobe is switched on number Key The bell is switched on to select next test The internal sounder is switched on Enter to exit 12 Walk test QI T All zones chime when activated LEDs light when zones open Enter to exit RINS 049 issue 1 13 J FUNCTIONALDESCRIPTION 3 1 Operating Modes 5 Tamper Alarm activated sounding internal audible alarm Panel unset Day mode Enter user code to clear internal audible alarm Re enter user code to clear TAMPER LED Now try setting the system If the system 5 goes straight into an alarm condition contact the engineer Day Mode This is the state of the panel when unset not armed Fire Personal Attack and Tamper inputs however remain active 24hours aday These are referred to as 24 hour zones Day mode is identified by the green day LED on the front of the panel Set Modes When the panel is set armed an activation of any Access Immediate or 24 hour zone will cause an alarm condition When an alarm is generated th