Home

Portable Multi-logger

image

Contents

1. ZR RX40A E AC adaptor AC cable Start up guide Base Set ZR XRE1 Extension Terminal Set Vw ZR XRT1 a ae Utility disk Logic Alarm Cable Content of utility disk ZR XRL1 Special PC software Trial version Standard PC software manual PDF file ZR RX40 Necessary option when channel is enhanced Item 20CH 40CH 100CH 200CH ZR RX40 Main unit 1 1 1 1 Base Set ZR XRE1 0 1 1 1 Extension Terminal Set ZR XRT1 0 1 4 9 WStandard Specifications Main unit Model ZR RX20A ZR RX40A Input method all channels isolated all channels isolated Resistance temperature detector is non isolated Input terminal shape M3 screw type terminal Number of input channels 10CH Standard 20ch Max 200ch When the terminal unit is connected Sampling interval Max 100ms 100ms 10CH max A D resolution 16bit Measurement Voltage 20 50 100 200 500mV 1 2 5 10 20 50V 1 5V F S ranges Thermocouples K J E T R S B N W WRe5 26 ae detector Uncorrespondence Pt100 JPt100 Pt1000 IEC751 Humidity 0 to100 Voltage OV to 1V Scaling conversion ZR XRH1 Refer to the option Logic 1CH Switch between logic4CH and pulse4CH Pulse 1CH Revolutions mode Counts mode Inst Mode switch method pulse type Revolutions mode Counts mode Inst Mode switch method Reference contact compensation Reference contact compensation accuracy Internal External switching
2. NE Portable Multi logger ZR RX40 ZR RX20 OMRON IRh AXd0 PORTABLE MULTI LOGGE F ree Ruri WIT rf 4 zar DIY UK ni ma T um MONT TOR i a 4 TUEN real z ng IN OMRON A USB 200b 12 01 D 10 34 04 MONITOR 1 CH1 26 1 tu I 0 1424 V ma 0 1394 _V iJ 7 0 1348 V io 0 1300 V Free Running i secvDIV Portable Multi logger I Up to 200 isolated channels IE Multifunction input thermocouples resistance thermometer voltage etc IELAN connection IHCompatible with USB flash drive internal 12 MB flash memory IM5 7 inch TFT color LCD IMEasy to navigate menus W9 hour battery option M3 screw terminal blocks WStandard PC software Standard 20 Channels Insulated amentals Versatility and Usability Secure Isolated Multi Input Multi input is possible for temperature humidity voltage logic and pulse Each channel is supplied with its own isolated circuit giving zero inter channel noise interference Maximum 200 Channel Expandability The terminal block just connect and go comes with 20 channels in standard configuration A maximum of 10 units can be connected to each logger easily creating a multi channeled measurement system to be used according to the number of channels needed Simple LAN Connection The embeded Web server function enables remote control from a web browser A USB connection me
3. 0 5 C 23 C 2 C when the input terminal temperature is balanced Maximum input Channel Terminals 60Vp p voltage Logic input Pulse p 24V input Trigger input Input impedance IMQ 5 Allowable signal source resistance Alarm output Number of channels Output format Less than 300Q 1CH 4CH Open collector output Output conditions Level judgment window judgment logic pattern judgment pulse judgment Trigger input 1CH PC I F Type USB 1 1 USB 2 0 LAN 10BASE T 100BASE TX PC I F Functions Data transfer to the PC realtime memory Web server function Operation of ZR RX40 FTP function Transfers and deletes measured data from internal memory via network Data transfer to the PC realtime memory Data save Measured data Internal memory 3 5MB Flash memory Internal memory 12MB Flash memry functions or direct capture in the USB memory device or direct capture in the USB memory device Other Setup conditions copy of data screen can be saved in the internal memory or USB memory device Display 3 5 inch TFT color LCD QVGA 320 x 240 dots 5 7 inch TFT color LCD QVGA 320 x 240 dots Display Language Japanese English US English UK French German Chinese Korean Operating environment Withstand voltage Power supply Voltage 0 to 40 C 30 to 80 RH 15 to 40 C when the battery 0 to 45 C 5 to 85 RH 15 to 40 C when the battery 350 Vp p between input channel GND
4. Small but fully fledged multi function input of 10 insulated channels Even with its small size the 10 isolated channel input can provide accurate and stable measurements The ability to input voltage humidity pulse and logic as well as temperature makes it practical in every field Pulse signal Logic signal input terminal input terminal Pulse Logic Temperature Humidity Voltage Comfortable Usability Connection No need For Wiring Detachable terminal blocks no need for wiring to the main body The ZR RX40 has removable terminal blocks which means that it can be wired up securely in narrow places just by detaching the blocks Also if the terminal blocks are left in the location they have been wired into there is no need to rewire them back to the main body when you want take repeat measurements Optional parts needed Connection with just one screwdriver It uses M3 terminal blocks for analog signal input The ring terminals and tongue terminals can be easily connected with just one screw driver There is no need for special tools so it can be used immediately ring terminal tongue terminal No need for AC Adapter With optional batteries there is no need for the AC adapter When fully charged the ZR RX20 and ZR RX40 can run for 6 hours and 9 hours respectively In the unlikely even that the batteries should cut out there is no need to worry
5. after the power supply is turned on Sampling interval 1 s 20 ch Filter ON Average 10 times GND connection Thermocouple used is T 0 32f other 0 65f Only ZR RX40 corresponds to the resistance temperature detector WModel Standard set Item Model Portable Multi Logger ZR RX20A E Portable Multi Logger ZR RX40A E External Dimensions ZR RX20 ZR RX40 Humidity Sensor ZR XRH1 Option Item Description Ambient temperature 25 to 80 C Ambient humidity Relative humidity measurement accuracy Response time 0 to 100 RH 3 RH 5 to 98 RH at 25 C 15 sec 90 response when membrane filter is installed Sensor output DCO to 1V External dimensions 14 x 80 mm excluding cable Cable length 3m PC Software Special PC Software ZR SX10 Wave Inspire RX OPTION Sold separately Trial version enclosed in the ZR RX standard set Standard PC Software Smart Viewer RX20 RX40 Enclosed in the ZR RX standard set Logging data display Real time PC data logging Piandang ZR RX setting CSV file conversion Direct drug amp move Scale change by numeric input Wave Scale batch change of all channels RX20 Operation Other Intuitive functions including Scale change of each channel by icon mouse wheel operation RX40 Wave TV display Single window division display Displa Allenannel muli Spale display Y T X Y and meter display selectable p ay Scroll UP Down
6. as the preceding data is saved with the data back up function ZR RX20 ZR RX40 Runs for Runs for 6 hours 9 hours Ai if ZR XRB 1 Battery pack one ZR XRB 1 Battery pack two Configuration Measurement No need for operation manuals Operates just like a mobile phone so you use it just by following your instincts rather than by following the manual Touching the NAVI button just once brings up a help screen so that you can operate it without the ponderous burden of browsing a manual nu Navigation screen Ge D re EDTV _ Disable Description of the SPAN POSITION TRACE key Changes the span position and trace values in the Digital area Operation Maintenance No need for time consuming work Easy display and easy editing with PC software Using the standard PC software provided graphs can be displayed on a PC or saved as Excel data Furthermore using the optional special PC software in addition to displaying graphs or saving Excel data it is possible to monitor multiple measurement data divided into groups so preparing data for reports is simple l email J aF sasana mini cia ai ALLL TLIE p V No need for initial set up with 3 way PC link 3 ways to link to a PC are available through a USB flash drive a USB connection or a LAN connection It is also possible to operate with wireless LAN with a commercially available wi
7. between each chs 1 minute AC adapter 100 to 240 VAC 50 to 60 Hz 9 DC input 8 5 to 24VDC Battery pack opitin Power consumption 28 VA or less when the AC adapter is used Weight 480g Excluding the AC adapter and battery 990g Including 1 terminal units Excluding the AC adapter and battery Measurement accuracy ZR RX20 ZR RX40 Commonness Voltage 0 1 of FS Thermocouple Measurement Temperature Range C Measureme R S O lt TS lt 100 5 2 C 100 lt TS lt 300 3 0 C R 300 lt TS lt 1600 C 0 05 of rdg 2 0 C S 300 lt TS lt 1760 C 0 05 of rdg 2 0 C B 400 lt TS lt 600 3 5 C 600 lt TS lt 1820 C 0 05 of rdg 2 0 C K 200 lt TS lt 100 0 05 of rdg 2 0 C 100 lt TS lt 1370 C 0 05 of rdg 1 0 C E 200 lt TS lt 100 0 05 of rdg 2 0 C 100 lt TS lt 800 C 0 05 of rdg 1 0 C T 200 lt TS lt 100 0 1 of rdg 1 5 C 100 lt TS lt 400 C 0 1 of rdg 0 5C J 200 lt TS lt 100 2 7C 100 lt TS lt 100 117 6 100 lt TS lt 1100 C 0 05 of rdg 1 0 C N O lt TS lt 1300 C 0 1 of rdg 1 0 C WwW 0 lt TS lt 2315 C 0 1 of rdg 1 5 C jeepers eee ee Curae lacunar Pt100 200 to 850 C FS 1050 C 1mA 1 0C JPt100 200 to 500 C FS 700 C 1mA 0 8 C Pt1000 200 to 500 C FS 700 C 0 2mA 0 8 C Features under the following measurement parameters Operating environment 23 C 3 C Left for at least 30 minutes
8. internal 12MB flash memory Inside has a 12MB flash memory It is also possible to connect it to commercially sold USB flash drive which means that the recording capacity can be selected as required according to application Do not use USB flash drive with security functions WPotential data recording time when 10 channels are used Recording interval sampling speed 100ms 200ms 500ms 1s 10s 12MB embedded flash memory 13hours 1day 3hours 2days 21hours 5days 58days 256MB USB flash drive 12days 25days 62days 125days 1256days LAN port enabling remote control from web browser Equipped with LAN port for Ethernet connection By connecting the ZR RX 40 to a PC with a LAN cable it is possible to set the logger up with your web browser You can take measurements from your own desktop Remote control LAN cable gm 10BASE T 100BASE TX Palm top Miniature light weight Portable Multi logger Z R zz RX 2 0 Not including battery AC adapter Input signal Voltage Humidity List of features Maximum All channels Thermocouples USB 3 5MB 10 channels isolated K J E T R S B N W flash drive internal memory 3 5 inch Easy to 6 hour Display 16bit TFT LCD J navigate menus battery switch resolution Easy to operate and easy to handle means that data can be gathered at ease even from equipment jammed into narrow spaces 4 Fu _ aw Dis d
9. left right pis Play i Setting Smart List view Tab form Display Smart grouping a M Between cursors All data File batch conversions Conversion Other pall eal a M functions ursor View omment input Comment input Excel transfer Alarm mail I F for Real time logging USB USB LAN OS Windows Vista XP 2000 Windows XP 2000 Option Item Model Battery Pack ZR XRB1 Humidity Sensor ZR XRH1 DC Cable ZR XRD1 Base Set ZR RX40 Special option goods ZR XRE1 Extension Terminal Set ZR RX40 Special option goods ZR XRT1 Logic Alarm Cable ZR RX40 Special option goods ZR XRL1 Special PC Software Wave Inspire RX ZR RX20 40 commonness ZR SX10 The temperature detector also abundantly does the lineup Unit mm ZR RX40 Main body y installation screw hole 2 M4 Depth 6 Portable Multi logger ZR RX20 RX40 This document provides information mainly for selecting suitable models Please read the document User s Manual Z257 Z260 carefully for information that the user must understand and accept before purchase including information on warranty limitations of liability and precautions Authorized Distributor Read and Understand This Catalog Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any guestions or comments Warranty and Limitations of Liability WARRANTY OMRON s exclusive warranty is that the prod
10. provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attention must be given This is not intended to be an exhaustive list of all possible uses of the products nor is it intended to imply that the uses listed may be suitable for the products e Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog e Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations e Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitions of use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Disclaimers CHANGE IN SPECIFICATIONS Product specifications and acces
11. also supports logic or pulse input input from external triggers as well as alarm signals output g GE ee ee ee ee ee eu 7 FPP FP HRP Pe Ree eS uk KE S S S S eee eee amp External input terminal Analog signal input terminal Logic alarm cable Logic Switches between logic and pulse Expandable up to 200 channels Each detachable terminal block has a standard 20 channels per unit Up to 10 units can be connected making it possible to extend up to as much as 200 channels It can also be used in car data logging where multi measurements of temperature voltage etc on many channels is needed Its seismic resistance corresponds to Class 1 A car parts JIS standards which means that it can be used stably even when there are vibrations and jolts during data gathering Base unit cable Length 60 cm Maximum 10 unit MAX connection 200CH t00k 12 0 p Br di t MONI TOR ALARH Outstanding Versatility Portable size only 990 grams Its light weight of 990 gram makes handheld measurement possible It is quite portable and can easily be slipped into your brief case when setting out on a business trip Including 1 terminal unit block Not including battery or AC adapter Easy to see 5 7 inch color TFT LCD Comes with bright easy to see high intensity 5 7 inch TFT large scale color LCD panel Its wide field of vision means it can even be seen at an angle USB flash drive and
12. ans a greater array of measurements is possible Standard PC software is also included Supper Light Mobile Model Also Available Portable Multi Logger ZR RX20A E I 10 isolated channels IE Multi channel input thermal resistance voltage etc IM Compatible with USB flash drive internal 3 5MB flash memory IM3 5 inch TFT color LCD W Easy to navigate menus W6 hour battery option I M3 screw terminal blocks IM Standard PC software channels Anyone Anytime Anyplace Portable Multi logger ZR RX4 Input signal Voltage Humidity Pulse List of features Maximum All channels Thermocouples id LAN USB 200 channels isolated K J E T R S B N W kepant function flash drive OMRON Free Running 12MB 5 7 inch Easy to 9 hour Display 16bit internal memory TFT LCD navigate menus battery switch resolution Advanced Fundamentals Detachable terminal blocks Expandable to 10 units option Optional parts needed when detaching or expanding All channels isolated Each circuit is electrically isolated so that the different channels do not affect each other Consequently there is no noise interference between the channels giving highly accurate and stable measurements Multi function input The temperature input supports thermocouples and resistance thermometer Furthermore in addition to temperature an array of measurements including humidity and voltage can be taken at once It
13. les or promotions without permission This catalog is protected by copyright and is intended solely for use in conjunction with the product Please notify us before copying or reproducing this catalog in any manner for any other purpose If copying or transmitting this catalog to another please copy or transmit it in its entirety sti i es OM RON Corporation In the interest of product improvement specifications are subject to change without notice Industrial Automation Company http www ia omron com c Copyright OMRON Corporation 2007 All Rights Reserved
14. re LAN to wireless LAN adapter to support your application needs ae F b USB flash drive USB cable LAN cable 6x ole lieli Ja ld E Carlee 0 Re oli lE Calibrations and certification on request Freely compare and quickly decide Smart grouping amp multiple display 3 step simple waveform observation at Grouping is simple by drag and drop into the created groups GT Multiple display For each group a waveform screen can be displayed so observation of comparisons between groups is possible Search selected channels in one operation After the search the channels have selected Status Tempe rature a Display for each input signal Compare multiple boards target Voltage na te __ I_E TIE Free movement and extremely F a E nabs wie has ribas rijai fans fu m r 2a Dm a a oal intuitive operation SSE e KW r Atom ji m m n it Br fe ti C t i IEC Aji Free adjustment function af eS o S cm V T Sm ji Click on wave form scale or cursor and move ants ee RL Ue Epee Pull down mans ah ety 06 02 9 55 Sampling 200ms 5 0 FE J A selection Setting and editing can all be completed from this screen Upe rr a he L uE at Hioo 4 15 0 tt 20 04 Lo50 G Change the position of the wave form with a single click of an icon x wa Displa
15. sories may be changed at any time based on improvements and other reasons It is our practice to change model numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the product may be changed without any notice When in doubt special model numbers may be assigned to fix or establish key specifications for your application on your reguest Please consult with your OMRON representative at any time to confirm actual specifications of purchased product DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of OMRON s test conditions and the users must correlate it to actual application requirements Actual performance is subject to the OMRON Warranty and Limitations of Liability PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user s programming of a programmable product or any consequence thereof COPYRIGHT AND COPY PERMISSION This catalog shall not be copied for sa
16. ucts are free from defects in materials and workmanship for a period of one year or other period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted INNO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the product At the customer s request OMRON will
17. y superimposed Tara z 1 en Tim Display side by side as wey Mim Maimik fipa Extremely easy to use compared with conventional logger software Bae Fats DA FA BA EMMA D A V Comm _ 80 days trial software is provided on the 3 M S i i un utility disk in a standard set Using the new special PC software Wave Inspire RX in a simple 3 step operation it is possible to compare each measurement or observe the waveforms for each input signal U M Major functions Observation of wave forms is very convenient when there is much measurement data Quick call up of fe cursor such as multi channel measurements multi measurements etc Also functions not available Special search function in standard software are provided such as directly dragging waveforms scales and cursors with a 3 en save function CSV save function mouse so that extremely intuitive operability that far exceeds that of E tp inting function conventional logger software is achieved I System Configuration Standard set ZR RX20A E AC adaptor AC cable Start up guide Common options Special PC Software DC cable 2m Battery Pack Humidity Sensor 3m ZR SX10 ZR XRD1 ZR XRB1 ZR XRH1 ZR RX40 Special options eUtility disk N USB flash drive can be used usually Content of utility disk Special PC software Trial version Standard PC software manual PDF file