Home
IR-Receiver User Manual
Contents
1. USER MANUAL IR RECEIVER OPENING AND LOCKING To open or lock the columns aim your remote control at the receiver eye and press the button The led lights on the columns will then light up and the columns will produce a short sound signal TIMER BUTTON Timer function locking automatically Upon delivery the timer function is on and set at an interval of 120 seconds 2 minutes When the frame security is unlocked the timer automatically locks it again after the interval The timer interval can be changed using the and the buttons on the re ceiver unit in stages of 30 seconds The maximum interval is 300 seconds 5 minutes The minimum 0 seconds switches the timer off When pressing the or the buttons a high or low sound signal is produced The maximum and minimum can be in stantly reached by pressing pressing the button or button for a longer period Comfort timer function Just before the automatic closure the green led on the receiver will blink and a tripple sound signal will be heard If desired to continue your sales pitch and keep the column s opened one push of the button of the remote control will extend the timer interval by 5 minutes A second push of the button of the remo te control during this 5 minute extension will lock the column s again The sales progress will not be inter ferred but security of the frames remains guaranteed During the ti
2. ess the desired group number on the remote control All columns that are connected to that specific receiver are now in this desired group The receiver accepted the group if you hear a short sound signal A double signal will be heard if it was an existing remote control Leave the programming mode by pressing the mode button shortly This is confirmed by three short sound signals and the led turning off When no programming action is executed for more then 60 seconds the programming mode is closed automa tically N CH w oO a Ga N C 1 1 2 Open all columns Close all columns Open all columns in group 1 Open all columns in group 2 o Open all columns in group 3 Q 2 Deleting groups If you wish to remove a group you will have to re move all codes You can do so by following these in structions Press the mode and the button simul taneously for a 5 seconds to erase all programmed remote controls This is confirmed by 3 sound signals The led will stay on during erasure followed by a long sound signal to confrm that all codes have been era sed You can add new codes with the adding code or creating groups procedure Factory settings 120 seconds On No groups pre programmed Timer Sound Group
3. mer interval it will always be possible to lock the frame security using the remote control MODE BUTTON and TIMER BUTTON Reset instructions Press the mode and the button simultaneously for a 5 seconds to erase all programmed remote con trols This is confirmed by 3 sound signals The led will stay on during erasure followed by a long sound signal to confrm that all the receiver has been reset Removing a code If you wish to remove all remote control codes or have a malfunction and desire a reset follow these instructions Press the mode and the button si multaneously for a 5 seconds to erase all program med remote controls This is confirmed by 3 sound signals The led will stay on during erasure followed by a long sound signal to confrm that all remote con trol codes have been erased You can add new codes by following the Adding a code instructions MODE BUTTON Adding or removing remote controls codes Each production order is given a unique remote con trol code to prevent misuse of the security system by third parties Upon delivery the code is pre programmed in the remote control and the receiving electronics If desired it is possible to add extra codes in a later stage It is also possible to erase programmed codes for example in case of loss or theft of one of the re mote controls Adding a code To add codes press the embedded mode button on the receiver for 3 sec
4. onds This will be confirmed by a long sound signal and the green led will light up Then aim the new remote controls at the receiver eye one at a time and press the button on the remote control The remote control is accepted if you hear a short sound signal A double signal will be heard if it was an existing remote control Leave the programming mode by pressing the mode button shortly This is confirmed by three short sound signals and the led turning off When no programming action is executed for more then 60 seconds the programming mode is closed automa tically Switch sound on off To turn the sound signals on or off press mode but ton for 3 seconds This will be confirmed by a long sound signal and the green led will light up Then presse the button to switch the sound off This is confirmed by 3 light signals Press the button to switch the sound back on This is confirmed by 3 sound signals Leave the programming mode as mentioned above BIAS lt a lt No gt N Creating groups of columns If you would prefer the columns to open in pre se lected groups you can do so by programming each column to belong to group 1 2 or 3 To program a receiver into a specific group press the embedded mode button on the receiver for 3 se conds This will be confirmed by a long sound signal and the green led will light up Then aim the remo te control at the receiver eye and pr
Download Pdf Manuals
Related Search
Related Contents
SmartScan User/Programming Manual MNPG87-03 - I-Tech Medical Division User manual User Manual PrecisionX™ LentiCas9 SmartNuclease System Bosmere A021 Use and Care Manual Samsung SGH-D500E User Manual Baumatic BRT200 fridge-freezer Wiley Photoshop CS4 Digital Classroom, (Book and Video Training) design Patrick Jouin for Alain Ducasse 2007 Copyright © All rights reserved.
Failed to retrieve file