Home
KW9M - atpsi.com.vn
Contents
1. KW Watcher cannot simultaneously display values of three phases in graphs si to two graphs for comparison A be displayed For specifications of KR20 Wireless Unit and DLL please refer to the individual catalogs 4 Feature 10 You can measure power with a direct connection to an already installed large capacity general purpose CT secondary side 1 A 5 A type The dedicated CT for Eco POWER METER cannot be used Use a CT with a secondary side current of 1A 5A Measuring power using another Eco POWER METER series Measuring power using large capacity general purpose CT Breaker Breaker Power supply Jae eee Short circuit or less than ae ae a ee 0 1 Q resistance K Secondary current AKW4801C i l TT JCT with 2nd current 1A 5A Whoo ose CT anna bese tens oh see ____________J a SNOt qL vA s required Ry co Ch ta J KW9M Hin zE Th I a Production equipment E Production equipment The measuring accuracy of the Eco POWER METER does not take the CT error into account Other Eco POWER METER series need to use two CTs 4 for measurement KW9M is ready for direct input from only one CT allowing higher accuracy measurements than with other Eco POWER METER series Application Example es eoopowerweTer AVVOM Example of a comprehensive solution for the entire factory
2. 2F Office area Distribution board for lighting system Motor pump wil i i i _ Blower and Fan heater FE KW Watcher i Cubicle 1F Factory area 4 Distribution board Air Production equipment KW Watcher cannot simultaneously display values of three phases in graphs Production equipment Up to two graphs for small size a can be displayed for power system Control panel conditioning large size 4 Lo For details of products other than KW9M please refer to the individual catalogs RS485 KW8M KW4M DLL Panasonic KW Watcher Ver 2 10 This product is licensed to sunx sunx Panasonic Industrial Devices SUNX Co Ltd 2008 2012 KW Watcher can be downloaded free of charge from our website You can also check the required operating environments Free software to create graphs from data collected by DLL for energy management Cumulative bar charts by equipment and pie charts anh dget as Comparison graphs by time and equipment Numeric display function Auto graph updating function KW Watcher cannot simultaneously display values of three phases in graphs Up to two graphs for comparison can be displayed Specifications MORDER GUIDE Product name Single phase two wire 1P2W KW9M Ec
3. 1 Remove the mounting clips from the unit 2 Insert the unit from the front of the panel 3 Attach the mounting clips at the both side of the case and secure in place with the screws e Applicable panel thickness 1 to 5 mm 0 04 to 0 20 in TERMINAL ARRANGEMENT AND WIRING DIAGRAMS Terminal wiring 1 Be sure to wire correctly according to the terminal arrangement and wiring diagrams 2 Please connect a fuse or a breaker to power supply part for safety reasons to protect the device and ease of maintenance This has no built in power switch circuit breaker or fuse for measured voltage input parts Therefore it is necessary to install them in the circuit near this unit 3 Do not turn on the power supply or input until all wiring is completed Common for terminal block A B Screw size M2 5 Tightening torque 0 4 to 0 5 Nem Applicable wire Crimp type terminal is recommended e Single wire 0 13 to 4 mm AWG26 to 12 e Stranded wire 0 2 to 4 mm AWG24 to 12 Rear view Terminal block A 10P Terminal block B e for 2 pcs 8P SSS Single wire Stranded wire 2 pcs USB port 0 5 to 2 1 mm AWG20 to 14 Stripping length 7 to 8 mm 0 28 to 0 31 in Terminal arrangement Terminal block A upper 10P 10 L N V1 V2 V3 Vn NC SG A B Functions AUX Power supply Measured voltage input Vacant RS485 Terminal
4. consumption Inrush current Allowable momentary power off time Tems Accuracy guarantee 10 to 55 C 14 to 131 F Si O n on aaa aa o TTT temperature Storage 25 to 70 C 14 to 158 F Ambient humidity 30 to 85 RH at 20 C 68 F non condensing Between the isolated circuits 2 000 V 1 min a enclosure all terminals b between insulated circuits e power supply terminals other terminals Between the e RS485 terminals other terminals isolated circuits measured current input terminals other 100 MQ or more terminals 10 to 150 Hz 7 5 minutes cycle KORES i single amplitude 0 075 mm 0 0030 in 1 h on 3 axes Milovetlamniesicumeem Tron rrr rrr rrr rcs cece ceca cccccca cs 10 to 55 Hz 1 minute cycle single amplitude 0 375 mm 0 015 in 1 hon 3 axes Breakdown voltage initial Insulation resistance initial Shock resistance Min 294 m s 5 times on 3 axes LCD with backlight Display updating time 100 ms Display method Power failure Internal memory overwrite 101 or more memory method Saved data setting value and integral measurement value Degree of protection Front IP51 Back IP20 Sea level altitude Under 2 000 m 6 562 ft Dimensions 96 x 96 x 56 mm 3 78 x 3 78 x 2 20 in without terminal block W H D 96 x 96 x 68 mm 3 78 x 3 78 x 2 68 in with terminal block Weight 450 g approx Single wire 1 pc Pe ae SOS PO a AWG26
5. block B lower 8P Terminal number Functions Vacant Measured current input Wiring diagrams Terminal block A upper Recommended fuse Time lag fuse Rated current 2A Single phase Terminal block B lower two wire system l Breaker To aed N A seri o Recommended AUX breaker Powersupply 3 to 15A cb 5a L1 R D o z E ae N z 2 K L Single phase Terminal block A upper Terminal block B lower three wire system Three phase three wire system Breaker 0b 9 L1 R gt L2 N S os a 95 5 L3 T Terminal block A upper Three phase four wire system Breaker Power supply side Load side Multi Function Power Meter Oth e rs Eco POWER METER KW9 M CE MARKING E Acquisition of CE marking E Applicable standard When using in the application conforming to EN61010 1 IEC61010 1 make ate Safet sure to satisfy the following conditions For using under the measurement ena EN61010 1 category IIl install varistors between the lines of power supply and the measured voltage input EMI Radiation interference field strength CISPR11 class A Environmental conditions EN61326 1 Noise terminal voltage CISPR11 class A e Overvoltage category Il Pollution degree 2 Static discharge immunity EN61000 4 2 a gt e ve RF electromagnetic field immunity EN61000 4 3 e An ambient temperature of 25 to 55 C 13 to 131 EELS immunit EN61000 4 4 e An ambien
6. t012 Cable conductor 0 2 to 4 mm Stranded cable 1 pc AWG24 to 12 Single wire stranded 0 5to 2 1mm cable 2 pcs AWG20 to 14 cross section Terminal connection Connection method Screw M2 5 Tightening torque 0 4 to 0 5 Nem EMEASUREMENT SPECIFICATIONS Measured data AC sine Single phase two wire 1P2W max 3 circuit Single phase three wire 1P3W Three phase three wire 3P3W and Three phase four wire 3P4W Common Applicable power system 100 V system 200 V system and 400 V system Phase Wire system Measured frequency 50 60 Hz Sampling rate 1 024 MHz 1 0 us approx Ot Gee 7771777277777h777777 7777r Date update 100 ms 0 to 500 VAC 0 to 500 VAC 1P3W Input voltage os 3P3W 0 to 500 V AC 0 to 500 V AC a 0 to 289 VAC O Impedance 2 MQ or more L N V1 V2 V3 Vn Resolution 0 01 V 2 Power consumption 0 2 VA approx L N V1 V2 V3 Vn Accuracy 0 5 Note 1 0 for 3 1 voltage of 1P3W 3P3W and line voltage of 3P4W 1 00 to 600 00 set with setting mode VT ratio Voltage transformer VT is required when you measure a load with voltage over rated voltage Rated secondary voltage of VT is 110 V When it input direct VT ratio is set to 1 00 Input current Primary current ___ 4 000 A or less aaa with CT Secondary current 1 A or 5 A set with setting mode a Max current 10 A 200 of the rating o Overload c
7. 5USB from LINE EYE Co Ltd When using SI 35 SI 35USB or PLC from our company which can be connected up to 99 units up to 99 can be connected In case using this system with the other devices up to 31 can be connected 3 Please check with the actual devices when some commercial devices with RS485 interface are connected The number of connected devices transmission distance and transmission speed may be different according to using transmission line lt USB gt Electric specification Protocol Transmission speed Transmission format Conform to USB2 0 standard Connector shape USB series Mini B Insulated to internal circuit 12 Mbps Full Speed Computer link MEWTOCOL Install the dedicated USB driver before using USB port Insulation method Transmission speed Transmission function Dimensions MEXTERNAL DIMENSIONS L196 14 013 76 Panasonic Eco POWER METER LCD Mounting Multi Function Power Meter Eco POWER METER KW9IM Unit mm in Terminal block Terminal block A HHH TE S SY HOHOHHHU cT GS r vc Terminal block B clip SHIFT Decrease key Panel cut out Panel mounting Keep enough space for several mountings Recommended space 130 mm 5 12 in the left right top and bottom from center of the unit Mounting screw M4x10
8. Panasonic Multi Function Power Meter ideas for life Eco POWER METER KW9M for Both Energy Saving andi Power surveillance eai 30000 Multi function type developed by adding a power surveillance function to a simple power meter KW9M Eco POWER METER is a new type of power meter which can promote energy saving by making power consumption visualization as with existing Eco POWER METER models This single meter KW9M also monitors power with high accuracy and functionality Energy Saving NASA CI OY L LIL VaVaVaVaVaVaVaVaV e Factory Infrastructure Freeway railway e Factory Power equipment Fields Store station facility etc Fields Store e Infrastructure Freeway railway Office e Theme park Office station facility etc e Public facilities e Visualizing power consumption by Applications department or equipment Monitoring power receiving and regenerative Monitoring for any waste of electric power Applications electric power Improving power factor Features Feature 1 A e Large screen LCD with backlight clearly displays values in four lines e High accuracy Instantaneous active power 1 Class 1 IEC62053 21 Display updating time 0 1 sec A 96 mm 10500 3 78 in i 000 z 30000 Bwana y KWwom 96 mm Feature2 3 78 in e The total and individual power values of each phase are displayed on one screen enabling you to check the phase balance at a glance The d
9. apacity 1 000 of the rating for 3s Resolution 0 001A Power consumption 0 2 VA approx Accuracy 0 5 Note 1 1 0 for 2 N phase of 1P3W and 2 S phase of 3P3W S Accuracy e T Note 1 Active power Class 1 IEC 62053 21 Note 2 2222 Reactive power Class 2 IEC 62053 23 Note 2 Temper 5 0 C 41 F after ambient temperature correction with setting mode ature Accuracy Passing 2 hours or more after energized Notes 1 Without error of current transformers CT and voltage transformers VT It measures from 0 1 of CT secondary current 2 IEC62053 is the international standard for Electricity metering equipment COMMUNICATION SPECIFICATIONS lt RS485 gt Interface Conforming to RS485 Communication method Half duplex Synchronous system Synchronous communication method Isolation status Isolated with the internal circuits MEWTOCOL MODBUS RTU DL T645 2007 Note 1 select with setting mode Number of connected unit 99 max Note 2 Transmission distance 1 200 m 3 937 ft Note 3 38 400 19 200 9 600 4 800 2 400 1 200 bps select with setting mode Data length 8bit fixed Not available odd number even number select with setting mode 1bit 2bit select with setting mode Notes 1 MEWTOCOL is the protocol for PLC from Panasonic DL T645 is the China power meter standard Only DL T645 2007 is supported 2 For RS485 converter on the computer side we recommend SI 35 and SI 3
10. ata is useful for power quality checks and power factor improvements Line voltage Phase voltage Current Power factor Preble se eet power Active power Reactive power Apparent power m p g 5 ERRE Annn iann 1 annn Phasa gt PALILA w UILLI iLL dots dewseede 20 mnnn gt 2 Ann gt 20 nnn Phase 2 gt TILL s7 UI evar 7 tL Phase 3 sssesese gt gt mamN w 3 mAN w SET aa AILI I 1 ULILILS fiva PETE nnnm annn annnm Total Ps sooo Suu 33000 Phase 1 Phase 2 Phase 3 i re 3 Arees saran NA nnn NAN Aciive UIL ww ILI ww UIL ww ESA iann nn wn Renoive d AILI or eat WLI vr oat WU wo eval nnn Vv nnn y ann Apparent gt LILII kva ALLII kva ALLII kva Current Voltage Phase Voltage Line F li li L LI LI ennn ennn 2 Hemmm PUHH PUHH PUHH gt Senna gt anna gt e annn uuu YUU BHH gt ehnA gt Tchad WeAnn pa aT ee tL 1 LULL satanataveds Icon ican ican Average gt F 159800 H mann A sigg e Panel mount type capable of multi circuit measurement e Capable of simultaneously measuring up to three circuits in a single phase two wire system of same power supply e Capable of displaying voltages currents electric power active reactive apparent and power factor al mora Power 1 supply gt Large key switches for easy operations Multi Functio
11. ble with SD memory cards For details please refer to the our website e The expansion unit power measurement and pulse or user s manual enables each expansion unit to produce pulse outputs e Connectable to various sensors using expansion units SO FTWARE TOO L analog pulse input type KW Watcher DLL is the abbreviation for Data Logger Light Measurement monitoring software Management Power Peo chase Puse Charge E Collected files stored according to unit of time on the Data logger are downloaded as required toa PC and Primary a Time graphs and numerical data can be displayed for simple Analog i nit set OK electric power water amount temperature primary unit and air flow amount measurement values E Measurement is in 15 min 30 min and 60 min units port MEWTOCOL MODBUS RTU KW Watcher can be downloaded free of charge from our website Customer registration is required before you download Before and after chart of KW Watcher integrated electric power ils cela te Panasonic Industrial Devices SUNX Co Ltd 2431 1 Ushiyama cho Kasugai shi Aichi 486 0901 Japan Global Sales Department MT elephone 81 568 33 7861 WFacsimile 81 568 33 8591 panasonic net id pidsx global Panasonic All Rights Reserved Panasonic Industrial Devices SUNX Co Ltd 2013 No CE KW9M 4 January 2013 Specifications are subject to change without notice Printed in Japan
12. n Power Meter KW9 M Eco POWER METER Feature4 4 e Capable of displaying small currents of 1 mA or above This allows for the monitoring of standby power consumption which helps energy saving 1 mA or above 800 i displayable E IER i Capable of measuring 0 1 or higher the rating of the secondary side of CT Feature 5 e Regenerative power can also be measured by one KW9M Eco POWER METER Bidirectional integrated electric power of each circuit can be measured Feature6 6 e A maximum of 66 kV high voltage power supply can also be measured by using VT Factory Building A Transformation A equipment An AON la W er 3 E XN TTT WF CHEN Kes itv foe eb Ce Pe eo es a X is KA s gt i OO Features Moa eeepower verer KVVOM Feature8 8 e Capable of measuring power primary side of inverter controlled equipment which is susceptible to harmonic effects e Ideal for measuring inverter power for large equipment lighting etc ry titit t t YY Compressor Molding machine Lighting Feature 9 e Data can be made visualization by connecting the meter to DLL and logging the data e The RS485 port is isolated for safe use Up to 99 KW9M units can be connected DLL is the abbreviation for Data Logger Light Office area 3F Distribution room n lt 0 m am EOT i sli i KW Watcher aw _ rer Cubicle
13. o POWER METER Single phase three wire 1P3W Standard type Three phase three wire 3P3W Three phase four wire 3P4W common Phase Wire system Input measurement voltage Input measurement current 0 to 500 VAC Multi Function Power Meter KW9 M Eco POWER METER Model No 1 to 4 000 A AKW91110 The dedicated current transformer CT can not be used Please use a general purpose CT with a secondary side 1A 5A EMEASUREMENT ITEMS Item Unit Active kWh Reactive kvarh 0 000 to 9999999 9 Apparent kVAh Integral power Active kWh Display data range Integral power import 0 000 to 9999999 9 export Reactive kvarh Active kW Instantaneous 99999 to 0 000 to 99999 Reactive kvar power Apparent kVA 0 000 to 99999 Current A 0 000 to 8000 0 Note Voltage V 0 00 to 99999 Note Power factor 1 000 to 0 000 to 1 000 Fixed 3 places of decimal Frequency Hz 0 00 to 99 99 Fixed 2 places of decimal Note 0 000 to 9999999 9 Temperature degree C 100 0 to 0 0 to 100 0 Fixed 1 place of decimal Note Convertion value Note Display data range is the range to be able to indicate with the main unit display it is not a range that can be measured EMAIN UNIT SPECIFICATIONS 85 to 264 V 100 to 300 V Supply voltage range Rated frequency 50 60 Hz a e a a A T 3 W approx 240 V DC at 25 C 77 F 30 A or less 240 V AC DC at 25 C 77 F Nominal power
14. t non condensing humidity of 30 to 85 RH at 20 C 68 F s l E EN61000 4 5 Altitude of 2 000 m 6 562 ft or less EMS ee ey pI e A minimum of dust and an absence of corrosive gases Power frequency magnetic field EN61000 4 8 e No flammable explosive gasses immunity e Few mechanical vibrations or shocks Voltage dip Instantaneous stop e No exposure to direct sunlight Voltage fluctuation immunity ee e No large capacity electromagnetic switches or cables through which large current is flowing Energy Consumption Visualization Components Data collection and storage Monitoring by LAN Ethernet For cases where wired connection is difficult For measuring multiple circuits DLL KS1 Signal Converter KR20 Wireless Unit KW2G SERIES Data Logger Light a eplensepnlagnkas e Collecting and storing power pulse and e Converting RS232C RS485 power e Wireless communications of RS232C e Up to 7 expansion units can be added analog data of Eco POWER METER data for communications by LAN RS485 power data e Up to 16 circuits measurement Single phase two wire e Provided with a USB port and an SD SDHC e 2 4 GHz band wireless communications system memory card slot e Compliant with wireless standards of e Setting from a PC is possible through a USB connection e Equipped with an AC DC power supply Europe and Japan e Compatible with DIN rails for installation e Provided with a RS232C RS485 communication f e The lineup includes a type compati
Download Pdf Manuals
Related Search
Related Contents
The Aspire Release 2 Software And New Hardware Now Available Samsung GT-E2652W Užívateľská príručka - World Cocoa Foundation Cannon 2764B004 Digital Camera User Manual Wireless USB Phone User's Manual EL-5300 User Manual Marmitek 08044 Multimedia-Projektor Benutzerhandbuch 4 -. ,5. - Université catholique de Louvain Kipor 2011 Dealer Warranty Package Copyright © All rights reserved.