        USER`S MANUAL
         Contents
1.                                  Choose this option to select the device driver from a list  Windows does not guarantee that  the driver you choose will be the best match for your hardware     10 New hardware search wizard starts to search        Found New Hardware Wizard    Please wait while the wizard installs the software         ga ISUSA USE DRIVER 2    2 z    Setting a system restore point and backing up old files in  case your system needs to be restored in the future        USER   S MANUAL 14    DSO3062L 3062AL  Digital Oscilloscope    11 New hardware wizard installs software and finish new hardware search wizard     Found New Hardware Wizard    Completing the Found New  Hardware Wizard    The wizard has finished installing the software for     D50  USE DRIVER 2    Click Finish to close the wizard     12  The wizard has finished installing for    USB DRIVER                          i  Found New Hardware x     Your new hardware is installed and ready to use        USER   S MANUAL 15    DSO3062L 3062AL  Digital Oscilloscope    1 4 General Features    Product Features     m Two Channels  Bandwidth   6OMHz    m Maximum real time sample rate   200MSa s    m Memory depth   10K 16M  CH  m Automatic setup for ease of use  AUTOSET        Pass Fail    m Built in Fast Fourier Transform function FFT       20 Automatic measurements      Automatic cursor tracking measurements    m Waveform storage  record and replay dynamic waveforms     User selectable fast offset calibration      
2.       Imdow Help  Cascade  Vertical  Horizontal    Arrange Icons    w 1 Seopel    11  Help  Turn on help file    Contents Fl  About    FY    1 3 The Vertical System    Click    Setup  gt Vertical       DSO3062L 3062AL  Digital Oscilloscope    The following figure shows the vertical Setup window  It shows the vertical parameters    setting     Fertical Setup    Select Channel    Channel Setting      MuDFF    VOLTS  DI     100w    Coupling   4c    Probe   x4    By Limit    Invert    USER   S MANUAL       2     DSO3062L 3062AL  Digital Oscilloscope    1 Select channel  User can select the channel by clicking the Combo box        3 VOLTS DIV  Set the selected channel voltage range     VOLTS   DM   1 00         4 Coupling  Set the selected channel to DC AC     Coupling             ta    5 Probe  Set the Select one according to the probe attenuation factor to ensure correct  vertical scale reading          Probe Fa We         7 Invert  Invert the selected wave     d Invert    USER   S MANUAL 28    DSO3062L 3062AL  Digital Oscilloscope    2 4 The Horizontal System    Click    Setup  gt Horizontal       The following figure shows the Horizontal System window  It shows the horizontal  parameters settings     Horizontal Setup    Time  DIY  5000us w       T Format        Normal   Scan    a   Y Setting    a   Coordinate Y  Coordinate    Cancel       1  Time DIV  leads the setting of the time base parameters    Time  DIY  50 00us      2  Format  leads the setting of the horizontal format 
3.     Parameter    Frequency      Hz  0   75MHz   w  035V   vot   T      ILO    1 0        oo 10       USERS MANUAL 91    DSO3062L 3062AL  Digital Oscilloscope    Generate the Trapezia waveform    To output a Trapezia wave  please do the following steps   1  Press the check box  On Off  to open the wave output function   2  Select the Wave Type  Trapezia     Frequency  Set the output wave frequency    Amplitude  Set the output wave amplitude    Y Offset  Set output wave vertical level offset    Phase  Set the output wave phase    Duty  Set the output wave duty    Rise Duty  Set the output wave rise duty    High Duty  Set the output wave high duty    Fall Duty  Set the output wave fall duty     The Trapezia waveform window as the following     Parameter    Frequency           0 0   1 0        Duty    Generate the Gause waveform       To output a Gause Wave  please do the following steps   1  Press the check box  On Off  to open the wave output function   2  Select the Wave Type  Gause    3  Set the Wave Paramters   Amplitude  Set the output wave amplitude     USER   S MANUAL 92    DSO3062L 3062AL  Digital Oscilloscope    The Gause waveform window as the following     Parameter    Amplitude         e aa       Generate the Arb  waveform    To output an Arbitrary Waveform  please do the following steps   1  Press the check box  On Off  to open the wave output function   2  Select the Wave Type  Arb     3  Set the Wave Parameters    Frequency  Set the output wave frequency   4  Set 
4.    Measure  gt Vertical  gt Peak to Peak    button  the Vpp of the signal will also  display on the bottom of the waveform interface     To clear the measurement on the waveform interface  click the    Measure  gt Clear    Measure    button        USER   S MANUAL 15    DSO3062L 3062AL  Digital Oscilloscope    4 2 Pass Fail Test    The Pass Fail function monitors changes of signals and outputs pass or fail signals by  comparing the input signal with the pre created mask   Pass Fail  Control   aoFF    Vertical  Rn i Diy  Horizontal  tener BE     SOUrCe       Stop When Output    Operate       Control Setting  Control       ONAOFF    SOURCE          Stop When Output    Source  Select the Pass Fail channel    Source   CH1 w      Output  Select the Pass Fail output condition    Output   FAIL s    Stop When Output  If it was checked  the Pass Fail will stop when output        Stop When Output    USER   S MANUAL 76    DSO3062L 3062AL  Digital Oscilloscope    Mask Setting  Mask    Vertical  Set the vertical limit range    Horizontal  Set the horizontal limit range    Horizontal   0 04     Dil       Create    button  Click this button to create Pass Fail area according to the mask       Save    button  Click this button to save the setups to file    Save       Load    button  Click this button to load the saved setups file     Load    Information Display       Fail   It shows the fail waveform number    Pass   It shows the pass waveform number    Total   It shows the   total Pass Fail 
5.    Probe x 2  1 5m   1 1 10 1   Passive Probes    A power adapter special for this product     A USB cable     A BNC to BNC     A logic analyzer cable     Eighteen little test hook      A software installation CD    USER   S MANUAL 21    Chapter 2 Operating Basics     The User   s Interface   The Menu System   The Vertical System   The Horizontal System   The Trigger System    Input Connectors    USER   S MANUAL    DSO3062L 3062AL  Digital Oscilloscope    22    DSO3062L 3062AL  Digital Oscilloscope    2 1 The User   s Interface    Click the software icon on the desk after you finished the software setting and equipment  connecting  Then a user interface will be showed as follows        1413 12 11 109    In addition to displaying waveforms  the display area is filled with many details about the  waveform and the oscilloscope control settings     1 The Main Menu  All settings can be found in the main menu     2 The Toolbar    3  It shows the trigger information  It shows the edge trigger slope  source and level     4 The Horizontal Panel    The user can change Time Div  format in the panel     5 The Vertical Panel   The user can turn on off the CH1 CH2  Also the user can change the CH1  CH2 volt div   coupling and probe attenuation    6 The LA Panel   In this panel  the user can set the LA voltage value     7  The Trigger Panel  In this panel  the user can change the trigger mode  sweep  source and slope     8  It shows the system time     USER   S MANUAL 23    DSO3062L 3062AL 
6.   1  Source      Cursor   Measure Acquir    Type d CH   MATH    The user can set the source to CH1  CH2 and MATH     When you use cursors  be sure to set the Source to the waveform on the display that  you want to measure     2  Type       cursor PO    Source        Cross  Trace  Vertical  Horizontal    There are four types of cursors  Cross  Trace  Vertical and Horizontal    1  Cross    The Cross cursors appear as cross lines on the display and measure the vertical and  horizontal parameters     USER   S MANUAL 57    DSO3062L 3062AL  Digital Oscilloscope    The Cross cursor display window   TrigD a OUST Lee ree 4 0 00uv    3454026    CH1 1 00   10 5 Time  500 0us          The Cross measure result displays on status bar  Freq  1 032KHz Time  J69u5 Volt  S08m      2  Trace    The Trace cursors appear as vertical lines on the display and measure the waveform  amplitude at the point the waveform crosses the cursor     The Trace cursor display window  TridD aL RAE tetera 0 00uv    3549752       mw 1 00V 5 Time  500 0us    USER   S MANUAL 58    DSO3062L 3062AL  Digital Oscilloscope    The Trace cursor measure result display on status bar       Volt   1  957  3  Vertical  The Vertical cursors appear as vertical lines on the display and measure the vertical    parameters     The Vertical cursor display window        The Vertical cursor measure result display on status bar       Freg  S20  1Hz Time  1  22ms  4  Horizontal    The Horizontal cursors appear as horizontal lines on the di
7.   The  oscilloscope continues to acquire data while waiting for the trigger condition to occur  The  oscilloscope continues to acquire enough data so that it can draw the waveform to the  right of the trigger point after it detects a trigger     The Edge trigger determines whether the oscilloscope finds the trigger point on the rising  or the falling edge of a signal  Select Edge trigger mode to trigger on Rising edge or  Falling edge     Mode  Select the trigger mode     Trigger Mode       Sweep  Set the sweep mode to Auto  Normal or Single     USER   S MANUAL 43    DSO3062L 3062AL  Digital Oscilloscope    Trigger Sweep       Auto  Acquire waveform even no trigger occurred  Normal  Acquire waveform when trigger occurred   Single  Acquire waveform when trigger occurred then stop    Source  You can use the trigger source options to select the signal that the oscilloscope  uses as a trigger  The source can be any signal connected to a channel BNC  or to the EXT   BNC     Trigger Source CHA    CH1  Select CH1 as trigger signal    CH2  Select CH2 as trigger signal  EXT   Select EXT as trigger signal  DO D15  Select DO D15 as trigger signal    Slope  Set the slope to Rising     or Falling         Trager Sone ANN      Rising  Trigger on rising edge  Falling  Trigger on falling edge    The user can also change the trigger setting on trigger panel in sidebar     Trigger    Trigger Mode  Trigger sweep AUTO t    Trigger Source CH wyt    Trigger Slope    Set Pulse Trigger    Pulse trigg
8.   The Square waveform window as the following     Parameter    Frequency          Amplitude       Y Offset       Phase     00  1 0         Duty        0 04 0     Generate the AM FM waveform    To output an AM FM Wave  please do the following Steps   1  Press the check box  On Off  to open the wave output function   2  Select the Wave Type  AM FM    3  Set the Wave Parameters   Frequency  Set the output wave frequency   Amplitude  Set the output wave amplitude   Y Offset  Set the output wave vertical level offset   Phase  Set the output wave phase   High Frequency  Set the output wave Hight Frequency   Depth  Set the output wave Depth   Max Frequency  Set the output wave Max Frequency   FM  Change the output wave  AM  into  FM      USER   S MANUAL 90    DSO3062L 3062AL  Digital Oscilloscope    The AM FM waveform window as following     Parameter    Frequency                                                                                                                                                                  Generate the Ramp waveform    To output a Ramp Wave  please do the following steps   1  Press the check box  On Off  to open the wave output function   2  Select the Wave Type  Ramp    3  Set the Wave Parameters   Frequency  Set the output wave frequency   Amplitude  Set the output wave amplitude   Y Offset  Set the output wave vertical level offset   Phase  Set the output wave phase   Duty  The duty of the output wave     The Ramp waveform window as the following 
9.   The results of the automatic measurements will be displayed on the bottom of the  screen  Maximum 8 results could be displayed at the same time  When there is no room   the next new measurement result will make the previous results moving left  out of screen     USER   S MANUAL 63    DSO3062L 3062AL  Digital Oscilloscope    3 8 The Display System    Display Type  Click    Type    in    Display    menu     The following figure shows the type parameters setting        Display  w rid Ctrl g Dots  Intensity    If the Vectors type mode is selected  the waveform will be displayed as following figure        USER   S MANUAL 64    DSO3062L 3062AL  Digital Oscilloscope    If the Dots type mode is selected  the waveform will be displayed as following figure        USER   S MANUAL 65    DSO3062L 3062AL  Digital Oscilloscope    Display Grid    Click    Display    in main menu    Display    w Grid Ctrl g Dots  Intensity       The grid shows   Trig D dhe DWAAAARAAAAAAA   0 00uv       mw 1 00V 15 Time  500 0us    The grid not shows   TrigD T j l       0 00uV       CH1 ny 10 6 Time  500 0us       USER   S MANUAL 66    DSO3062L 3062AL  Digital Oscilloscope    Intensity and Persistence    Click    Display  gt Intensity    in main menu     The following figure shows the intensity dialog  It shows the display parameters setting     Intensity    Setting     rid f Scale    Waveform       You can change the grid and waveform color intensity in this dialog        USER   S MANUAL 67    DSO3062L 3062
10.  All Terminal Ratings  To avoid fire or shock hazard  observe all ratings and  markings on the product  Consult the product manual for further ratings information before  making connections to the product     m Use Proper Probe  To avoid shock hazard  use a properly rated probe for your  measurement     m Avoid Circuit or Wire Exposure  Do not touch exposed connections and components  when power is on     m Do Not Operate With Suspected Failures  If suspected damage occurs with the device   have it inspected by qualified service personnel before further operations     m Provide Proper Ventilation  Refer to the installation instructions for proper ventilation of  the device       Do not operate in Wet Damp Conditions     Do not operate in an Explosive Atmosphere     m Keep Product Surfaces Clean and Dry     USER   S MANUAL 3    DSO3062L 3062AL  Digital Oscilloscope    Chapter 1 Getting Start    The oscilloscope is small  lightweight  no external power required  portable oscilloscopes   The oscilloscopes is ideal for production test  research and design and all of the  applications involving analog circuits test and troubleshooting  as well as education and  training     In addition to the list of general features on the next page  this chapter describes how to do  the following tasks     m System Requirements   m Install your product     General Features   m General Check   m Perform a probe check and compensate probes  m Match your probe attenuation factor   m Use the self ca
11.  B    Source A and Source B Menu       Operate   Four Types    A B Add source A and source B   A B Subtract source B from source A   AxB Multiply source A by source B   A B Divide source A by source B   FFT Convert a time domain signal into its frequency components  spectrum      In this function  use the addition  subtraction  multiplication and FFT function to operate  and analyze the waveform     USER   S MANUAL 37    DSO3062L 3062AL  Digital Oscilloscope    Select the operate type in the Operate menu  Select source A and B  Then adjust the  vertical scale and offset to view the math channel clearly  The mathematic result can be  measured by the measure and the cursor   The Math Function Display             PR pt 1                                                                                           Invert    The invert function turns the displayed waveform 180 degrees  with respect to the ground  level  When the oscilloscope is triggered on the inverted signal  the trigger is also inverted     Click    Invert    in MATH      invert    USER   S MANUAL 38    The following picture shows the waveform before inversion   Trig D Ae    nu 10 0      The following picture shows the waveform of inversion   TridD aie    fy 10 0      USER   S MANUAL          DSO3062L 3062AL  Digital Oscilloscope      0 00UW    2324326    Time  500 0us      0 00uVw    2402522    Time  500 0us    39    DSO3062L 3062AL  Digital Oscilloscope    Set Reference    Click    REF    in    Setup    menu to s
12.  Digital Oscilloscope    9  Marker shows Edge trigger level   10  It shows the main time base setting   11  It shows the LA channel setting on off status     12  It shows the CH2 information   Readouts show the coupling of the channels    Readouts show the vertical scale factors of the channels   A    B    icon indicates that the channel is bandwidth limited    13  It shows the CH1 information   Readouts show the coupling of the channels    Readouts show the vertical scale factors of the channels   A    B    icon indicates that the channel is bandwidth limited    14  It shows the software status     15  The markers show the LA reference points of the displayed waveforms  If  there is no marker  the channel is not displayed     16  The markers show the CH2 reference points of the displayed waveforms  If there  is no marker  the channel is not displayed     17  The markers show the CH1reference points of the displayed waveforms  If there  is no marker  the channel is not displayed     18  A window that shows the display waveform in buffer position     19  The LA Bus   20  Marker shows horizontal trigger position     21  Trigger status indicates the following    AUTO  The oscilloscope is in auto mode and is acquiring waveforms in the absence of  triggers    Trig   D  The oscilloscope has seen a trigger and is acquiring the post trigger data   WAIT  All pretrigger data has been acquired and the oscilloscope is ready to accept a  trigger    STOP  The oscilloscope has stopped acqui
13.  The oscilloscope recalls this setup the next time you run the software  You can  use the    Save Setup    menu to permanently save up to several different setups     Load Setup    The oscilloscope can recall the last setup before the oscilloscope software was running   any saved setups  or the factory setup  You can use the    Load Setup    menu to  permanently recall a setup     Factory Setup    The oscilloscope software is set up for normal operation when it is shipped from the factory   This is the factory setup  To recall this setup  push the    Factory Setup    menu     USER   S MANUAL 34    DSO3062L 3062AL  Digital Oscilloscope    3 2 Set Vertical System    Set Channel  Click    Vertical    in    Setup    menu   The Channel Selection    Select Channel  CH  yt    The Channel Control Panel in sidebar    Vertical       The Vertical function     Turn ON Off  Turn on off the channel  VoIt DIV  Select the channel voltage div  Coupling  Select the channel coupling  Probe  Select the channel probe attenuation  Invert  Turn on off the invert function     Change Volt DIV    You can click voltDiv in    vertical Setup    window to select the voltage    VOLTS DM   1 00        You can also change the selected channel voltage in sidebar    Vertical  CH1      e ONOFF  00v     r    Je  4    T       USER   S MANUAL 35    DSO3062L 3062AL  Digital Oscilloscope    You can left click and drag the mouse on the knob to change the voltage   Set Channel Coupling    Click    Coupling    in    Ve
14.  Type  Set the Trigger Type to Edge or Pulse     USER   S MANUAL 46    DSO3062L 3062AL  Digital Oscilloscope       Trigger Type  PW Condition  Set the PW Condition to the following condition     More   Pulse width more than selecting pulse condition     Less   Pulse width less than selecting pulse condition     Equal   Pulse width equal to selecting pulse condition     More   Pulse width more than selecting pulse condition     Less   Pulse width less than selecting pulse condition     Equal   Pulse width equal to selecting pulse condition   Pulse Width  The Pulse Width adjust range is 10ns 10s  When the condition is met  it will    trigger and acquire the waveform     Pulse Fidth Setting    n  hal       The user can also change the trigger setting on trigger panel in sidebar     Trigger  Trigger Mode   ALT   Trigger Channel   CH1 wt  Trigger Type   Pulse wt  PYY Condition    Less      Pulse Vyictth 10 0ne    Halal    USER   S MANUAL 47    DSO3062L 3062AL  Digital Oscilloscope  2  Set Bus Trigger    The Bus mode includes three trigger modes     Trigger value  Trigger at the appearance of a specified value on the selected bus   Duration  Trigger at x time after the appearance of a specified value     Edge  Trigger at the appearance of a specified value on the selected bus and rising  falling   or rising edge of the selected signal     Trigger Setup    Single   Bus   Advanced  setting    Trigger Mode    Trigger Value       3 Setup Advanced Trigger    If the basic trigger can   t
15.  meet your requirement  you need the advanced trigger setup   Trigger Setup    Single       Us Advanced        Data   Min lo Data     Duration   Min joins Time  Max jo   xin    F  Edge    SOUrce Slope    d Relative Trigger       USER   S MANUAL 48    DSO3062L 3062AL  Digital Oscilloscope    There are four parts in the conditions  Data  Duration  Edge and Relative trigger     High Frequency Rejection    Select    HF Rejection    in    Trigger Setup    window    Trigger Setup    single   Bus Advanced    setting                                     Trigger Mode Ede    Trigger Sweep AUTO    Trigger Source   CHi    Trigger Slope          The user can turn on    HF Rejection    to eliminate trigger higher frequency  20M above     USER   S MANUAL 49    3 5 Save Load    Save    Click    File    in main menu to save waveform  setups and screen     eR  View Setup Display    Hew Ctrlti  Close   Load Data CtrltL  Load Setup   cave Data Ctrlts  nave Setup    Save  mage    Print    CtrltF  Print Preview    Print Option    Connect    Exit    1  Save Data    Save waveform data as a type file  2  Save Setup    Save the current oscilloscope setup to file  3  Save Image    Save the software display window as a  bmp or  jpg file    Load    Click    File    in main menu to recall saved waveform  setup    1  Load Data  Load the waveform that had saved as a type file  2  Load Setup    Load the instrument that had saved    USER   S MANUAL    DSO3062L 3062AL  Digital Oscilloscope    50    DSO3062L 306
16.  waveform  It can stop playing back if you started    playing back        Start    button  Click this button to start a record setup     Start    Note  When it plays back waveform  the other channel will be turned off     USER   S MANUAL 52    DSO3062L 3062AL  Digital Oscilloscope    Pass Fail    Click    Pass Fail    in    Utility    menu     Record       Pass Fail    FC d    Calibration  Factory Setup    Language d    The Pass Fail window appears     Pass Fail    Control    ON OFF l    _  L Vertical We EB Diy  SOUrce 2a  Horizontal  anwar  BE Diy    Load    Operate       The Pass Fail function monitors changes of signals and outputs pass or fail signals by  comparing the input signal with the pre created mask     Control Setting  Control     ONOFF    SOURCE    Output v       Stop When Output    Source  Select the Pass Fail channel    Source   CH1 ka  Output  Select the Pass Fail output condition     USER   S MANUAL 53    DSO3062L 3062AL  Digital Oscilloscope    Stop When Output  If it was checked  the Pass Fail will stop when output        Stop When Output    Mask Setting  Mask    Vertical  Set the vertical limit range    Horizontal  Set the horizontal limit range       Create    button  Click this button to create Pass Fail area according to the mask    Create       Save    button  Click this button to save the setups to file    Save       Load    button  Click this button to load the saved setups file    Load    Information Display       Fail   It shows the fail waveform 
17. 2AL  Digital Oscilloscope    3 6 Utility Function    Record and Play Back    Click    Record    in    Utility    menu     Utility   Vehicle W     Record  Pass Fail    FC d    Calibration  Factory Setup    Language d    The Record window will display  The following picture shows the Record Interface     Record And Play Hack  Record Setup    SOURCE  End Frame    Record    Play Back Setup    Start Frame      End Frame    Current Frame       This function can record input waveform form CH1  CH2  The maximum record length is  1000 frames     Record Setup window    Record Setup    End Frame   1 000     Record j    4       Source  Select record source channel   CH1  CH2     USER   S MANUAL 51    DSO3062L 3062AL  Digital Oscilloscope    End Frame  Set the number of record times  The max frames are 1000    End Frame 1000        Record  Record counter  it shows the record frames   Record j     Start    button   Start to record frames  After you start to record waveforms  this button changes to     Stop    button  It stops recording waveforms   Play back setup window    Play Back Setup    Start Frame    End Frame   1000       Current Frame    Start Frame  Set the start frame of play back     Start Frame           r    End Frame  Set the end frame of play back    End Frame 1000 2    Current Frame  It shows the current frame of play back  You can also change this number  to watch the waveform one by one     Current Frame 1           Play    button   Click this button to start playing back
18. AL  Digital Oscilloscope    3 9 Zoom In Out and Drag Waveforms    The software will stop updating waveform after the user clicked    Stop    button    The user can change the waveform display by adjusting the scale and position    When you change the scale  the waveform display will increase or decrease in size    When you change the position  the waveform will move up  down  right  or left    The channel reference indicator identifies each waveform on the display  The indicator  points to the reference level of the waveform record     ee Vee    w Eun Ctrltk  Stop Ctrlto  Butfer Length d  Acquisition d  Interpolation d  Autoset    Zoom In Out   The user can click    Zoom In Out    in    Acquire    menu  then left or right click the mouse  button on display screen to zoom in out the waveform  Also the user can change  Time Div in Horizontal menu or in Horizontal panel to zoom in out the waveform     Drag    The user can modify the waveform position after clicked    Drag    in    Acquire    menu  following the following steps     Drag Waveforn    Operation    Memory Data Length   10240    Move Step  1000         USER   S MANUAL 68    DSO3062L 3062AL  Digital Oscilloscope    1 Select Channel     CH1 k    2 Set the Move Step     Move Step  1000    3 Change the waveform position        USER   S MANUAL 69    DSO3062L 3062AL  Digital Oscilloscope    3 10 Interpolation    At the time base 40ns div or faster  user can use the 3 different interpolation mode to get  waveforms of differe
19. Add  Subtract and Multiply Mathematic Functions      Selectable 20 MHz bandwidth limit    m External trigger    m Waveform average    m Adjustable waveform intensity  more effective waveform view     m User interface in several user selectable languages     USER   S MANUAL 16    DSO3062L 3062AL  Digital Oscilloscope    1 5 General Check    Please check the instrument as following steps after receiving an oscilloscope     Check the shipping container for damage    Keep the damaged shipping container or cushioning material until the contents of the  shipment have been checked for completeness and the instrument has been checked  mechanically and electrically     Check the accessories   Accessories supplied with the instrument are listed in  Accessories  in this guide  If the  contents are incomplete or damaged  please notify the franchiser     Check the instrument   In case there is any mechanical damage or defect  or the instrument does not operate  properly or fails performance tests  please notify the franchiser     Probe Compensation    Perform this function to match the characteristics of the probe and the channel input   This should be performed whenever attaching a probe to any input channel at the first  time     m From the    Probe    menu  select attenuation to 1 10  Set the switch to    X10    on the probe  and connect it to CH1 of the oscilloscope  When using the probe hook tip  insert the tip  onto the probe firmly to ensure a proper connection     m Attach the pro
20. Condition  Less   Pulse width less than selecting pulse condition    Equal   Pulse width equal than selecting pulse condition    More   Pulse width more than selecting pulse condition       Set Pulse Width highlighted  including Time Unit and  PASE aR o Pulse Width       USER   S MANUAL 45    DSO3062L 3062AL  Digital Oscilloscope    Video Trigger   Mode  Select the trigger mode     Trigger Mode Video       Sweep     Trigger Sweep AUTO yt    Source  Set the Trigger Channel to CH1 CH2     Trigger Channel    Trigger Sync     Trigger Syne All Lines     i    Trigger Standard     Standard Pay Sec Ww    m  With Video highlighted  an NTSC  PAL or SECAM  Video standard video signal will be triggered  The trigger    coupling is preset to AC     Auto  Acquire waveform even no trigger occurred   Sweep Normal  Acquire waveform when trigger occurred  Single  Acquire waveform when trigger occurred  then stop     CH1 Select the input source as the trigger signal  Ext use  Source CH2 the signal applied to the EXT TRIG connector as the  EXT source     All Lines   Line Number   Choose a proper video sync  When selecting Line  sync Odd Field Number for the Sync option  you may use the User   Even Field Select knob to specify a line number    All Fields    Standard NTSC Choose a video standard for sync and line number  PAL SECAM count        Set ALT System  Mode  Select the trigger mode     Trigger Mode   p30  i    Trigger Channel  Set the Trigger Channel to CH1 CH2     Trigger Channel    Trigger
21. Connector       CH1 CH2  Input connectors for waveform display     EXT   Input connector for an external trigger source  Use the Trigger Menu to select the Ext     Source     Other Connector        OUTPUT  Signal output    GND   a ground terminal   USB PORT  Connect the USB cable to this port   10 115  The LA input data channels    CAL   Probe compensation output     GPower  Power Input port     USER   S MANUAL 32    DSO3062L 3062AL  Digital Oscilloscope    Chapter 3 Oscilloscope Functions     Set Oscilloscope    Set Vertical System   Set Horizontal System   Set Trigger System   Save Load   Utility Function     Measure Signal    Zoom In Out Waveforms    Acquire Signal   Print    USER   S MANUAL 33    DSO3062L 3062AL  Digital Oscilloscope    3 1 Setup the Oscilloscope    Using    AUOSET    to display a signal automatically    Auto setup functions one time each time you push the    AUTOSET    button  The function  obtains a stable waveform display for you  It automatically adjusts the vertical scale   horizontal scale and trigger settings  Auto setup also displays several automatic    measurements in the graticule area  depending on the signal type   Connect a signal to the CH1 input    1  Connect a signal to the oscilloscope as described above    2  Click the    Acquire   gt  Autoset    button    The oscilloscope will change the current settings to display this signal   Save Setup    The oscilloscope software saves the current setup before you close the oscilloscope  software 
22. Digital Oscilloscope    1  Click    Print    in    File    menu to set the printer to print the current waveform  2  Click the    PrintPreview       in    File    menu to get into the Preview window     In    PrintPreview    window  use the    Zoom In    button and the    Zoom Out    button to  change the size of the waveform graph  Click the    Close    button to turn this window off  and click the    Print    button to print the report     The Print report     Test Report    DSO 3062AL USB    Date   0208 2012 Time   11 20 35       USER   S MANUAL 13    DSO3062L 3062AL  Digital Oscilloscope    Chapter 4 Application Example     Sample Measurement  Pass Fail Test    Capturing a Single Shot Signal   The Application of the X Y   Taking Cursor Measurement      Arbitrary Waveform Generator    USER   S MANUAL 74    DSO3062L 3062AL  Digital Oscilloscope    4 1 Simple Measurement    To acquire and display a signal  please do the steps as follows   1  Connect signal to CH1 by using probe  2  Click the button on toolbar or    Acquire   gt  Auto Setup    on menu     The DSO set the vertical  horizontal  and triggers controls at the best status automatically   Also  you can adjust the controls to meet your measurement to optimize the waveform  display     To measure the frequency and    Vpp     you can do these steps as follows     1  Click the    Measure  gt Horizontal  gt Frequency    button  the frequency of the signal  display on the bottom of the waveform interface     2  Click the 
23. E dade datecode E 76  4 3 Capturing a Single Shot Signal                 ccccccssscccccssseecceseeeceeseeeceeseeecsegsesessaseeesssaseees 19  4 4 The Application of the X Y Operation  pp 80  4 5 Taking Cursor Measurements  pp 82  A OO Cay Ze lk T arate rtadatadata data dastadatatatadatadaia setae laden datadaadan ducha dada dahe tuchadeaat  85  4A Navel orm Generato nae 88  Chapter 5 ADDendix              cccecccceececeeceeeeeeeceeceeseeeeeeserseseeeeeataeeees 96  Appendix A  Specifications  pp 97  APPEnNdIX B ACCOSSONGCS orinn a S 100    Appendix C  General Maintenance   pp 102    DSO3062L 3062AL  Digital Oscilloscope    General Safety Summary    Review the following safety precautions carefully before operate the device to avoid any  personal injuries or damages to the device and any products connected to it   To avoid potential hazards use the device as specified by this user s guide only       To Avoid Fire or Personal Injury    m Use Proper Power Cord  Use only the power cord specified for this product and certified  for the country of use     m Connect and Disconnect Properly  Do not connect or disconnect probes or test leads  while they are connected to a voltage source       Connect and Disconnect Properly  Connect the probe output to the measurement  device before connecting the probe to the circuit under test  Disconnect the probe input  and the probe reference lead from the circuit under test before disconnecting the probe  from the measurement device     m Observe
24. Hantek     USER   S MANUAL    DSO3062L DSO3062AL       http   www hantek com    Content    General Safety Summary  pp 3  Chapter 1 Getting          ae 4  TU SV SCOT AR OCIS men eras ae ee eee 5  1 2 Install Software  4 6  NS 10  eneIeEea     Sa 16  oe Cre  ale     i CNECK camer teen eee arta eee oe ere eee ae ce ee ee a ee te ae eee ee nee ete ene eee ee eee ener 17  Me Oe CMON IL OGA acetate ea eacaciecediederiodamededaderiededenedadecedaderedadediededietedadediadedatedadedndadadead 19          20  WeAocsssones a Senn Goo adane EEE EEE EE EAEE EEEE ES 21  Chapter 2 Operating Basics  pp 22  a Ws Bt gy   eh WW Ke excel  goles CE 23  2 2 TNE Menu System  4 25  to  WUT vencal SY SUTIN anni narnia ernie leneiaainitiaie 27  2 4 The Horizontal System  pp 29  ASe Tigger SY SION ee eae 30  ZONA CN ORI O head ace cen NENN 32  Chapter 3 Oscilloscope Functions  pp 33  321 SelUD Ne OSCIIIOSCODE ksnar E 34  3 2 Set Vertical System 35  Oo TU AOFIZ OR Vaal SVS COU a 41  3 4 Set Trigger System  4 43  OS  OIC ease eee E E S A A A E E 50  SOUU EGG     51  OE ISAS US SONA acta eae teen eae nae aaa maa 57  3 9 The Display Syste eee sire tate sented seteediavede setoadeaniedia aa aai 64  3 9 ZOOM INOUE and Drag WavefonMNS esser eee det Seeded  68      70  Ol ACOUISHHOM MORG S Acciona Kae eae es ee ee 72  912 PIMAN TING PTO VICW isisao n O E 72  Chapter 4 Application Example  pp 14  AA Simple MeasuUremienle 222 cess aia aaa Sieadio aera acd eta aaa rd aid ener a 15  AZ FoS F AN WS Ste ae ese ec A 
25. Hardware Wizard    Please wait while the wizard installs the software       DS0   a USE DRIVER 1    DSio l SYS  To CAWIN DOW S  Systens2 Drivers    7 Finish new hardware search wizard     Found New Hardware Wizard    Completing the Found New  Hardware Wizard    The wizard has finished installing the software for     DS0 W USE DRIVER 1    Click Finish to close the wizard     USER   S MANUAL          Lancel    ape e ale  Lance    DSO3062L 3062AL  Digital Oscilloscope    8 New hardware is found     i  Found New Hardware  x     DS0 xxxx USB DRIVER 2    This wizard helps vou install software for     DSO  USE DRIVER 2        If your hardware came with an installation CD  LEA or floppy disk  insert it now     What do vou want the wizard to do         Install the software automatically  Recommended   O  Install from a list or specific location  Advanced     Click Next to continue                             USER   S MANUAL 13    DSO3062L 3062AL  Digital Oscilloscope    9 Set the driver search location to CD Rom or the driver path     Found New Hardware Wizard    Please choose your search and installation options  eS        Search for the best driver in these locations     Use the check boses below to limit or expand the default search  which eludes local  paths and removable media  The best driver found will be metalled        Search removable media  floppy  CD ROM        Include this location in the search         Don t search    will choose the driver to install                    
26. Setup Status    DS0 30624L USE is configuning your new software installation                 InstallShield           T  The installation is complete     DS0 3062AL USB   InstallShield Wizard    InstallShield Wizard Complete    Setup has finished installing OS0 30624L USE on pour  Computer           _ Finish I   Cancel       USER   S MANUAL 9    DSO3062L 3062AL  Digital Oscilloscope    1 3 Install Driver    Example  DSO3062AL  1  Connect the A Type Plug of USB cable to your PC   s USB port             3  New hardware is found     i  Found New Hardware  x     IS0 xxxx USB DRIVER  1       USER   S MANUAL 10    DSO3062L 3062AL  Digital Oscilloscope    4  New hardware search wizard starts     Found New Hardware Wizard    This wizard helps you install software for     DSO  USE DRIVER 1        If your hardware came with an installation CD   lt 4 or floppy disk  insert it now     What do vou want the wizard to da         Install the software automatically  Recommended   O  Install from a list or specific location  Advanced     Click Next to continue     5 New hardware search wizard starts to search the driver                    Found New Hardware Wizard    Please wait while the wizard installs the software       ga ISOTA USE DRIVER 1    2      Setting a system restore point and backing up old files in  case Your system needs to be restored in the future        USER   S MANUAL 11    DSO3062L 3062AL  Digital Oscilloscope    6 New hardware wizard installs    USB DRIVER        Found New 
27. The LA BUS reference points of the displayed waveforms     Display Style  You can set the display style of the bus in the waveform  Analog or Digital     USER   S MANUAL 85    DSO3062L 3062AL  Digital Oscilloscope    Analog     prt rre ttre rrr preter rrr yrrrrprrr rye rrrprr rrr rT       Digital        Display Format  The format of the bus data displayed on the waveform   Click    Setup      gt     Bus     gt     Data          E hislar Cursor Meas    REF Ctrltk  MATH Ctrl M  Trigger CtrltT  Vertical Ctrlty  Horizontal CtrltH    Trigger Release Ctrlth    mE  Logic Calibrate s  Hex    Hex        Decimal        USER   S MANUAL 86    DSO3062L 3062AL  Digital Oscilloscope    Plug in I7C    Click    Setup     gt     Plug in          Select the plug in and click the    Set    button  you can set up the configurations of the    plug in        USER   S MANUAL 87    DSO3062L 3062AL  Digital Oscilloscope    4 7 Waveform Generator    Caution  This part is only used for DSO3062AL     DSO 3062AL can also be used as the Arbitrary Waveform Generator  with one channel of  arbitrary waveform output  8 Bits output  synchronized signal out puts  User can edit the  waveform arbitrary by the mouse or choose the regular waveforms such as Sine  Square   AM FM  Ramp  Trapezia  Gause  Arb  Exponent  White     Select the DDS control panel in the sidebar         pso   DDS      Jonot    Syne     Single  Wave Type    O sine C SQUare CANE NM  OQ Ramp    Trapezia CO GAUZE  CO Arkh f Exponent White    Param
28. all power sources     To clean the exterior surface  perform the following steps     1  Remove loose dust on the outside of the oscilloscope and probes with a lint free cloth   Use care to avoid scratching the clear glass display filter     2  Use a soft cloth dampened with water to clean the device     USER   S MANUAL 102    
29. be tip to the Probe Compensator and the reference lead to the ground  connector  select CH1  and then press the    AUTOSET    button into the menu or the  toolbar     m Check the shape of the displayed waveform     Correctly Compensated    USER   S MANUAL 17    DSO3062L 3062AL  Digital Oscilloscope    Over Compensated    Under Compensated    1  If necessary  use a non metallic tool to adjust the trimmer capacitor of the probe for the  fattest square wave being displayed on the oscilloscope   2  Repeat if necessary     WARNNING  To avoid electric shock while using the probe  be sure the perfection of the  insulated cable  and do not touch the metallic portions of the probe head while it is  connected with a voltage source     USER   S MANUAL 18    DSO3062L 3062AL  Digital Oscilloscope    1 6 Function Check    Perform this functional check to verify that your oscilloscope is operating correctly     m Connect the oscilloscope  You should connect the A Type Plug of USB cable to your PC USB port and connect the  other A Type Plug of USB cable to oscilloscope USB port        m Input a signal to a channel of the oscilloscope  The oscilloscope is equipped with two channels plus external trigger     Please input signal in the following steps     1  Set the attenuation switch on the probe as 10X and connect the probe on the  oscilloscope with CH1  Aim the slot in the probe connector at the faucet on BNC of CH1  and insert  then  turn right to lock the probe  Finally  attach the tip of 
30. ed  Time Div control expands or compresses the  waveform     USER   S MANUAL 41    DSO3062L 3062AL  Digital Oscilloscope    Change Format    Click    Time Div    you can Set the Time base in Horizontal Setup window     Time olw  5000us 4    In the    Format    item  set the waveform display format  Y T  X Y      Y  T   Show the relative relation between vertical voltage and horizontal time  X  Y   Show CH1 value at X axis  CH2 value at Y axis    Change Horizontal Position    Double click the channel button to set the trigger point to the horizontal center of the  screen     Horizontal position changes the displayed waveform position  relative to the trigger point     The user can drag LA on screen to change the horizontal position     USER   S MANUAL 42    DSO3062L 3062AL  Digital Oscilloscope    3 4 Set Trigger System    Click    Setup  gt Trigger     you can configure the trigger     The user can also click T in the toolbar to set Trigger     1  Set Single Trigger    Trigger Setup  ingle   Bus   Advanced  Setting  Trigger Mode Edge    Trigger Sweep AUTO    Trigger Source CH1    Trigger Slope        HF Rejection       Edge Trigger    The trigger determines when the oscilloscope starts to acquire data and display a wave   form  When a trigger is set up properly  it can convert unstable displays or blank screens  into meaningful waveforms  If the oscilloscope wants to acquire a waveform  it collects  enough data so that it can draw the waveform to the left of the trigger point
31. er occurs according to the width of pulse  The abnormal signals can be  detected through setting up the pulse width condition     Trigger Mode  Mode     Trigger Sweep       Sweep     Trigger Source CHi hgt  Source     USER   S MANUAL 44    DSO3062L 3062AL  Digital Oscilloscope    PW Condition    Less a    Pulse Width  The Pulse Width adjust range is 10ns 10s  When the condition is met  it will    trigger and acquire the waveform     Pulse Width Setting    Time Units   ns    The user can also change the trigger setting on trigger panel in sidebar        Trigger    Trigger Mode Pulse  t  Trigger Sweep AUTO wt          Trigger Source  CH1 w  Puy condition    Less         Pulse Width      When alternative trigger is on  the trigger sources come from two vertical channels  This  mode can be used to observe two non related signals  You can choose two different trigger  modes for the four vertical channels     With Pulse highlighted  the trigger occurs on pulses that  Pulse meet the trigger condition  defined by the Source  When  and Set Pulse Width options    Auto  Auto  Acquire waveform even no trigger occurred  Sweep Normal  Normal  Acquire waveform when trigger occurred    Single Single  Acquire waveform when trigger occurred then stop     CH1  CH2 Select the input source as the trigger signal   EXT     Less   Pulse width less than selecting pulse condition    Equal   Pulse width equal than selecting pulse condition   PW  More   Pulse width more than selecting pulse condition   
32. eshold range  Max Sample Rate  Bandwidth  Compatible input    Storage depth    Waveform Frequency  A    Frequency Resolution    O    Channel  Waveform Depth  Vertical Resolution  Frequency Stability  Wave Amplitude  Output Impedance    O1        Output Current 50mA  lpeak 50mA  system BW 25M  Harmonic Distortion  50dBc 1KHz    40dBc 10KHz     Current Range CC65 20A  CC65 60A  CC650 CC 1100    Cursor Time frequency difference  voltage difference    USER   S MANUAL 99    DSO3062L 3062AL  Digital Oscilloscope    8  36V Wide range of input voltage   Power Source   i  suitable for vehicle power test  255 x 190 x 45  mm   Weight       Appendix B  Accessories    DSO3062L Accessories    X1  X10 two passive probes  The passive probes have a 6MHz  bandwidth  rated 100Vrms CAT III  when the switch is in the X1  position  and a maximum bandwidth  rated 300Vrms CAT II   when the switch is in the X10 position  Each probe consists of all  necessary fittings     A power adapter special for this product  In addition to the power  adapter shipped with your instrument  you may purchase  another one certified for the country of use     A USB line  used to connect external devices with USB interface  like a printer or to establish communications between PC and  the oscilloscope     A 20 pin logic analyzer exhaust line    ARAARI fit Eighteen little test hook HT321     Logic analyzer with high quality test hook     T R    A software installation CD and it contains the user manual for  the oscillosc
33. et REF channel      J OMOFF    wolt d Diy Time ylw  50 00us         Drag    Ref DataLen  O Move Step    1000                The Reference Channel Function     On Off  Turn on off the reference channel    Volt DIV  Channel the resolution of the reference channel    Load  Load the reference waveform from the     rfc    file from your computer    Save  Save the current reference waveform to your computer as  rfc format    Save Reference  Save the current reference waveform to your computer as    rfc    format   You can change the vertical scale of a waveform  The waveform display will contract or  expand relative to the reference level     Load  Click    Load    to load the      rfc    file that was selected  The load file window will appear   Save    Click    Save    to save the waveform to   rfc file  The saved source window appears     Select a channel       The save file window will appear after you selected the saved source     USER   S MANUAL 40    DSO3062L 3062AL  Digital Oscilloscope    The Reference Waveform Display Window     i    Note  If you turn on the    Reference    channel  the load file window will appear        3 3 Setup Horizontal System    Change Time Div  The    Time Div       SO  00us      Selects the horizontal Time DIV  scale factor  for the main or the window time base    Time t Dry       The Horizontal Panel    Horizontal    Time t DI                    50 004 v             Click the blue knob can change Time Div     If the waveform acquisition is stopp
34. eter    Frequency          Hz  0   7S5MHZ   Amplitude    Y  O35     WoT ow PM       A    Click any button of certain waveform to switch to the output of such kinds of waveform      O 0 1 0    The user can select wave type as below     Wave Type    O sine   SQUare CO AMF M    Ramp O Trapezia O GAUSE    O Ark     Exponent  White    USER   S MANUAL 88    DSO3062L 3062AL  Digital Oscilloscope    Waveform Parameter Setup    Select a wave type  and you can set the    Parameters    in the sidebar   Generate the Sine waveform    To output a Sine Wave  please do the following steps   1  Press the check box  On Off  to open the wave output function   2  Select the Wave Type  Sine Wave    3  Set the Wave Parameter   Frequency  Set the output wave frequency   Sweep  Set the output wave to sweep   Amplitude  Set the output wave amplitude   Y Offset  Set the output wave vertical level offset   Phase  Set the output wave phase   The Sine waveform window as the following        Parameter    Frequency    Generate the Square waveform    To output a Square Wave  please do the following Step   1  Press the check box  On Off  to open the wave output function   2  Select the Wave Type  Square    3  Set the Wave Parameters   Frequency  Set the output wave frequency   Amplitude  Set the output wave amplitude   Y Offset  Set the output wave vertical level offset   Phase  Set the output wave phase   Duty  Set the duty of the output wave     USER   S MANUAL 89    DSO3062L 3062AL  Digital Oscilloscope  
35. lShield Wizard will install OSO 30624L USB on  your computer  To continue  click Mest     DSO S3062AL USE     InstallShield Wizard    Customer Information    Please enter your infosmation     User Name     Microsoft Users             Microszott Users          Install this apphcabon for        Anyone who uses this computer  all users   O Only for me  Microsoft Users     Install hield       USER   S MANUAL    DSO3062L 3062AL  Digital Oscilloscope    4  Choose a Setup Type directory  Click  Next  to continue   DSO 30627AL USB   InstallShield Wizard  Setup Type    Select the setup type to mstall    Click the type of setup you prefer  then click Next       Typical Program vall be installed with the most common options  Recommended for    most users     Program vall be installed vaith minimum required options        fou may select the options you want to install  Recommended fo advanced  UEIS        5  Check the setup information  Click Next to start copying of Files     DSO 30627AL USB     InstallShield Wizard    Start Copying Files  Review settings before copying files     Setup has enough infomation to start copying the program files  If you want bo review or  change any settings  click Back  If pou are satshed with the settings  cick Next to begin  copying files    Current Settings                                USER   S MANUAL 8    DSO3062L 3062AL  Digital Oscilloscope    6  This Status dialog is displayed during copying of Files     DSO S067AL USB     InstallShield Wizard    
36. le  if you generated an 1 KHz  sine waveform  you will also  generate an 1 KHz  square waveform simultaneously  The software setting is following  figure     Sine Frequency  1000 000 Hz V Pk to Pk    4 000 Y       The waveform on CH1 is the sine waveform you generated from the    OUTPUT    terminal   and that on CH2 is the synchronized signal from    SYNC OUT    terminal        USER   S MANUAL 95    DSO3062L 3062AL  Digital Oscilloscope    Chapter 5 Appendix      Appendix A  Specifications      Appendix B  General Maintenance    USER   S MANUAL 96    DSO3062L 3062AL  Digital Oscilloscope    Appendix A  Specifications    Specifications Table     DSO3062L  Vertical  Analog Channels  Bandwidth  Rise Time    60MHz  3dB    5 8ns   Resistance  1MQ  Capacitance  25 pF  10mV div to 5V div   AC DC GND   8 bits   10K 16M CH   400V  DC AC Peak     Input Impedance  Input Sensitivity  Input Coupling  Vertical Resolution  Memory Depth    Maximum Input    Real Time    Sampling Rate eee    Time Base Range ons div to 1000s div 1 2 5 sequences     Time Base Precision     50ppm    Trigger  Source  Mode   X Y mode  X Axis Input    CH1  CH2 D0 D15 EXT  Edge  Pulse  Video  Alternative        L    L  N    Y Axis Input  Phrase Shift  Cursors and Measurement    Max 3 degree    Vpp  Vamp  Vmax  Vmin  Vtop  Vmid  Vbase  Vavg     Voltage Measurement Vrms  Vcrms  Preshoot  Overshoot    Frequency  Period  Rise Time  Fall Time  Positive Width   Negative Width  Duty Cycle    USER   S MANUAL 97    Time Measu
37. libration routine    m Accessories    USER   S MANUAL 4    DSO3062L 3062AL  Digital Oscilloscope    1 1 System Requirement    To run the oscilloscope software  the needs of computer configuration are as follows   Minimum System Requirements    Operating System  Window XP VISTA Win7    Processor  Upwards of 1 00G processor    Memory  206M byte    Disk Space  500M disk free space    Screen resolution  800 x 600    Recommended Configuration    Operating System  Windows XP SP3 System    Processor  2 4G Processor    Memory  1G Byte Memory    Disk Space  80G Disk Space    Screen resolution  1024 x 768 or 1280 x 1024 resolution    DPI Setting  Normal Size  96DPI     USER   S MANUAL 5    DSO3062L 3062AL  Digital Oscilloscope    1 2 Install Software    Caution  You must install the software before using the oscilloscope     1  While in Windows  insert the installation CD into the CD ROM drive   2  The installation should start up automatically  Otherwise in Windows Explorer  switch  to the CD ROM drive and run Setup exe     InstallShield Wizard    Preparing to Install       O50 30624L USB Setup is preparing the Installshield  Wizard  which will guide you through the program setup  process  Please wait      Preparing to Install       Cancel       USER   S MANUAL 6    DSO3062L 3062AL  Digital Oscilloscope    3 The software Installation is started  Click  Next  to continue     DS0 30624L USB     InstallShield Wizard    Welcome to the InstallShield Wizard for  DSO 30624L USE    The Instal
38. n  The arithmetic mean over the entire waveform   Cycle Mean  The arithmetic mean over the first cycle in the waveform    Preshoot  Positive Overshoot    Max   Top  Amp x 100    Measured over the entire  waveform    Overshoot  Negative Overshoot    Base   Min  Amp x 100    Measured over the entire  waveform     USER   S MANUAL 61    DSO3062L 3062AL  Digital Oscilloscope    3  Horizontal    Measure   Aequire Utility  Source    Vertical    Horizontal Period    Clear Measure CtrltM Frequency       Rise Time    Fall Time      Duty Cycle    Duty Cycle      Pulse Width    Pulse Width    Period  Time to take for the first signal cycle to complete in the waveform   Frequency  Reciprocal of the period of the first cycle to complete in the waveform   Rise Time  Time taken from lower threshold to upper threshold   Fall Time  Time taken from upper threshold to lower threshold    Duty Cycle  Positive Duty Cycle    Positive Pulse Width  Period x 100   Measured of  the first cycle in waveform     Duty Cycle  Negative Duty Cycle    Negative Pulse Width  Period x 100   Measured of  the first waveform     Pulse Width  Measured of the first positive pulse in the waveform  The time between the  50  amplitude points    Pulse Width  Measured of the first negative pulse in the waveform  The time between the    50  amplitude points    USER   S MANUAL 62    DSO3062L 3062AL  Digital Oscilloscope    4  Clear Measure    Clear all measure items on display screen     The Measure Display Window        Note
39. nt smoothness     The Step Interpolation        The  Linear Interpolation     USER   S MANUAL 70    DSO3062L 3062AL  Digital Oscilloscope    The Sin x  x Interpolation        Note  The default interpolation mode is Sin x  x   Acquisition    When you acquire a signal  the oscilloscope converts it into a digital form and displays a  waveform  The acquisition mode defines how the signal is digitized and the time base  setting affects the time span and level of detail in the acquisition     USER   S MANUAL 71    DSO3062L 3062AL  Digital Oscilloscope    3 11 Acquisition Modes    There are two acquisition modes  Normal  Average and Peak Detect     w Kun Ctrl k  Stop Ctrlto    Buffer Length d       Acquisition    Interpolation d Ayer age d    Feak Detect  Autoaset    Normal  In this acquisition mode  the oscilloscope samples the signal in evenly spaced  intervals to construct the waveform     Average  In this acquisition mode  the oscilloscope acquires several waveforms  averages  them  and displays the resulting waveform  You can use this mode to reduce random  noise     Peak Detect  In this acquisition mode  the oscilloscope finds the maximum and the  minimum in every sampling interval  and use these values to show waveform     3 12 Print And Print Preview    setup Display       CtrltH  Load Data CtrltL  Load Setup  cave Data Ctrlts  cave Setup    Save  mage    Ctrl de       Print Preview    Print Option    Connect    Advanced        Exit    USER   S MANUAL 72    DSO3062L 3062AL  
40. number    Pass   It shows the pass waveform number    Total   It shows the   total Pass Fail waveform number    USER   S MANUAL 54    DSO3062L 3062AL  Digital Oscilloscope    Operation  Operate    Click    Start    button to start the Pass Fail test     Click    Stop    button to stop the Pass Fail test     The Pass Fail function display       NOTE  Pass Fall function is unavailable in X Y mode     Factory Setup  Click    Factory Setup    in    Utility    menu to load default setups    Vehicle W     Record    Fass Fail       Factory Setup    Language      When you click the Factory Setup in Utility menu  the oscilloscope displays the CH1  and CH2 waveforms and removes all other waveforms     The oscilloscope set up for normal operation when it is shipped from the factory and can be  recalled at anytime by user     USER   S MANUAL 55    DSO3062L 3062AL  Digital Oscilloscope    The Factory Setup function does not reset the following settings     m Language option  m Date and time    Language  Click    Language    in    Utility    menu    Record  Fass Fail    F C      Calibration  Factory Setup       Language Default English  Hepi  w English  Deutsch    There are four languages in    Language    menu  The default language is English     USER   S MANUAL 56    DSO3062L 3062AL  Digital Oscilloscope    3   Measure Signal    Cursor Menu    Click    Cursor    in main menu        Lursor Messi    Source        Type d    This method allows you to take measurements by moving the cursors  
41. opes        USER   S MANUAL 100    DSO3062L 3062AL  Digital Oscilloscope    DSO3062AL Accessories       USER   S MANUAL    X1  X10 two passive probes  The passive probes have a 6MHz  bandwidth  rated 100Vrms CAT III  when the switch is in the X1  position  and a maximum bandwidth  rated 300Vrms CAT II   when the switch is in the X10 position  Each probe consists of all  necessary fittings     A power adapter special for this product  In addition to the power  adapter shipped with your instrument  you may purchase  another one certified for the country of use     A USB line  used to connect external devices with USB interface  like a printer or to establish communications between PC and  the oscilloscope     A PROBE HT322     A 20 pin logic analyzer exhaust line    Eighteen little test hook HT321   Logic analyzer with high quality test hook     A software installation CD and it contains the user manual for  the oscilloscopes     101    DSO3062L 3062AL  Digital Oscilloscope    Appendix C  General Maintenance    General Care  Do not store or leave the oscilloscope where the device will be exposed to direct sunlight  for long periods of time     Caution    To avoid damages to the device or probes  do not expose them to sprays  liquids or  solvents     To avoid damages to the surface of the device or probes not use any abrasive or chemical  cleaning agents     Cleaning    Inspect the device and probes as often as operating conditions require  Make sure the  device disconnect form 
42. parameters    USER   S MANUAL 29    DSO3062L 3062AL  Digital Oscilloscope    2 5 The Trigger System    Click    Setup  gt  Trigger       The following figure shows the trigger system control     Trigger Setup    Single   Bus Advanced    setting    Trigger Mode Edge yt  Trigger Sweep   AUTO    yt    Trigger Source             Trigger Slope       HF Rejection       Single Trigger    1 Trigger Mode  Sets the trigger mode   2 Trigger Sweep  Selects the trigger sweep mode to AUTO  NORMAL or SINGLE  3 Trigger Source  Selects the trigger source to CH1  CH2  DO D15  EXT     4 Trigger Slope  Selects the edge trigger slope to Positive or Negative slope    Bus Trigger    The Bus mode includes three trigger modes   Trigger value  Trigger at the appearance of a specified value on the selected bus   Duration  Trigger at x time after the appearance of a specified value   Edge  Trigger at the appearance of a specified value on the selected bus and rising     falling  or rising edge of the selected signal     USER   S MANUAL 30    DSO3062L 3062AL  Digital Oscilloscope  Trigger Setup          Advanced  Setting    Trigger Mode    Trigger    value wt       Advance Trigger     There are four parts in each condition  Data  Duration  Edge and Relative trigger value  Trigger Setup         Single   Bus   Advanced     Data  hin    wax     C  Duration  Min xsns Time    Max xSns    F  Edge    SOUrCe    F  Relative Trigger       USER   S MANUAL    31    DSO3062L 3062AL  Digital Oscilloscope    2 6 Input 
43. probe and ground nip  to the Connector of Probe compensator                 2  Set the CH1 probe attenuation of the oscilloscope to X10   The default is X1      USER   S MANUAL 19    DSO3062L 3062AL  Digital Oscilloscope       3  Attach the tip of probe and ground nip to the Connector of Probe compensator  Click the        button  A square wave will be displayed within a several seconds   Approximately 1  kHz  2V  peak  to  peak      4  Inspect CH2 with the same method  Repeat steps 2 and 3     1 7 Self Calibration    The self calibration routine lets you optimize the oscilloscope signal path for maximum  measurement accuracy  You can run the routine at any time but you should always run  the routine if the ambient temperature changes by 5v or more  For accurate calibration   power on the oscilloscope and wait twenty minutes to ensure it is warmed up  To  compensate the signal path  disconnect any probes or cables from the input connectors   Then  access the    Utility   gt  Calibration    option and follow the directions on the screen   The self calibration routine takes about several minutes     USER   S MANUAL 20    DSO3062L 3062AL  Digital Oscilloscope    1 8 Accessories    All the accessories listed below are standard accessories for the oscilloscope   DSO3062L       Probe x 2  1 5m   1 1 10 1   Passive Probes    A power adapter special for this product     A USB cable     A logic analyzer cable     Eighteen little test hook      A software installation CD  DSO3062AL    
44. rement       DSO3062L 3062AL  Digital Oscilloscope    200mV to 100V div   20 1        Logic Analyzer    Others  Current Range CC65 20A  CC65 60A  CC650 CC 1100  F    p 8  36V Wide range of input voltage suitable  ower Source  for vehicle power test    Volume 255 x 190 x 45  mm   Weight    DSO3062AL    Bandwidth 60MHz  3cB      1         Maximum Input 400V  DC AC Peak     Real Time  Sampling Rate eee  Time Base Range ons div to 1000s div 1 2 5 sequences     Time Base Precision  50ppm    Source CH1  CH2 D0 D15 EXT    Mode Edge  Pulse  Video  Alternative    X Y mode       USER   S MANUAL 98    DSO3062L 3062AL  Digital Oscilloscope    Vpp  Vamp  Vmax  Vmin  Vtop  Vmid  Vbase  Vavg   Vrms  Vcrms  Preshoot  Overshoot    Voltage Measurement    Frequency  Period  Rise Time  Fall Time  Positive Width   Negative Width  Duty Cycle    Horizontal  Vertical  Track  Auto Measure Modes    Time Measurement       Cursors Measurement    Waveform Signal Process         x    FFT  Invert   Voltage Range  10mV to 5V div   x 1 probe  100mV to 50V div   x 10 probe  1V to 500V div   x 100 probe  10V to 5000V div   x 1000 probe  100V to 50000V div   x 10000 probe  200mV to 100V div   20 1    Logic Analyzer  High input impendence 200K C 10p     60V 60V    8 8V   100MHz   10MHz   TTL  LVTTL  CMOS  LVCMOS  ECL  PECL  EIA  10K 68M CH   Arbitrary Waveform Generator Mode   DC 25MHz   2K 2Z00MHz adjustable   0 10    1CH waveform output   4KSa   12 bit    lt 30ppm    3 5V Max     Input Voltage range  Logic thr
45. ring waveform data    RUN  The oscilloscope is running    PLAY  The oscilloscope is displaying the record waveforms     USER   S MANUAL 24    DSO3062L 3062AL  Digital Oscilloscope    2 2 The Menu System    The Main Menu     File View Setup Display Cursor Measure Acquire Utility Vehicle Window Help    1 File  Load or Save data  setup    EOE  View Setup Display  Hew Ctrlti    Load Data CtrltL  Load Setup    cave Data Ctrlts  Save Setup    Save  mage    Print    CtrltF  Print Preview    Print Option    Exit    2 View  Change the user interface    w Toolbar  ww Status Bar  ww Side Bar    3  Setup  Setup setting    FE 7i splay Cursor Weasi    REF Ctrltk  MATH Ctrltm  Trigger CtrltT  Vertical Ctrlty  Horizontal CtrltH    Trigger Release Ctrltkh    Bus      Plug in    USER   S MANUAL 25    4 Display  Change wave display type    eae Cursor Measw       Type d  w Grid Ctrltty  Intensity    5 Cursor  Set Cursor measure type    E i     Source P    Type d    6  Measure  Set measurement parameters    Measure   Aequire Utility    Sor ce    Vertical    Horizontal      Clear Measure CtritM    7 Acquire  Run  Stop or other operation setting           w Fun Ctrltk  Stop Ctrlto  Buffer Length d  Aequisition d  Interpolation d  Autoset    8 Utility  Utility setting    Record    Pass Fail  FC d    Calibration  Factory Setup    Languaze d    USER   S MANUAL    DSO3062L 3062AL  Digital Oscilloscope    26    9  Vehicle     Tiagnosis Setup    Clear reference waveform    10  Window  Window setting     
46. rtical Setup    window    In the sidebar  you can change the channel coupling too     Vertical  CH1 vw OMJOFF  200  A    al    l     i       You can set the coupling to DC  AC or GND  If you set the coupling to DC  it blocks the AC  component of the input signal     Probe Attenuation Setting    Select the attenuation factor for the probe  To check the probe attenuation setting  toggle  the probe menu to match the attenuation factor of the probe     This setting remains in effect before you changed again     Click    Probe    in Vertical Setup window to select the probe attenuation    The probe setting window in the sidebar    Vertical  Zono   20v i   0g     O    Note  The attenuation factor changes the vertical scale of the oscilloscope so that the  measurement results refect the actual voltage levels at the probe tip        Set Math  Click    MATH    in Channel menu to set MATH channel     USER   S MANUAL 36    DSO3062L 3062AL  Digital Oscilloscope    The MATH Setup window     BATH Setup       ONMOFF    Operate    4 6  Oa B  VOLTS   DIV OAxB  Oars  C  FFT    Source 4   CH1    Source A CH2 wy    Cancel       ON OFF  Turn On Off the MATH Channel    Source A B  Set the sources of the math channel    Operate  Set operates type of the math channel    Volt DIV  Set the resolution of the math channel    Probe  Set the math channel probe attenuation    Invert  Turn on off the invert function   The mathematic functions include addition  subtract  multiply and FFT for CH2     Source A
47. scilloscope    Signal in X Y Format        Instruction of the Ellipse Method    Signal must be  centered in X    i  i i    A B    I7 7  e   T       Sin     A B or C D  where 6   phase shift  in degrees  between the two signals   From the formula above   9  _arcsine  A B  or _arcsine  C D     8 must be in the range of  O 11 2  or  311 2 2T1  if the main axis of the ellipse is between    and Ill quadrant    If the main axis is at Il and IV quadrant  8 must be in the range of  11 2 Tr   or  1I 3T1 2      USER   S MANUAL 81    DSO3062L 3062AL  Digital Oscilloscope    4 5 Taking Cursor Measurements    Use cursors to make time and amplitude measurements on a waveform quickly   Measure the Peak Frequency or Time of the First Sine Waveform   Do these steps    1  Click    Cursor  gt Source     select CH1  select CH2 if you want measure CH2    2  Click    Cursor  gt Type     select Vertical    3  Push left mouse button  and the vertical lines appear    4  Drag the mouse button to the point you want to measure   5      Release the left mouse button  the frequency difference and time difference will be  shown at the status bar     Measure the Frequency and Time        Read the details showing in the status bar     Freq  1  3B1EHz Time  TASUS    Measure the Amplitude of the First Waveform Peak of the Waveform  Do these steps     1  Click    Cursor  gt Source     select CH1  select CH2 if you want measure CH2    USER   S MANUAL 82    DSO3062L 3062AL  Digital Oscilloscope    2  Click    Cur
48. sily  such as the noise with large  amplitude  set the trigger level higher a little above the normal level and press and wait   When noise occurs  the instrument will record the waveform before and after the trigger     USER   S MANUAL 19    DSO3062L 3062AL  Digital Oscilloscope    4 4 The Application of the X Y Operation    X Y Plot acts to analyze correlation of data of two channels  Lissajous diagram is displayed  in the screen when you use X Y Plot  which enables to compare frequencies  amplitudes  and phases of counterpart waveform against the reference waveform  This makes it  possible to compare and analyze frequency  amplitude and phase between input and  output     Do these steps as follows    1  Set the probe attenuation to    x10    Set the switch to    x10    on the probes    2  Connect the CH1 probe to the input of the circuit  and connect the CH2 probe to the  output of the circuit    3  Click D  button     4  Adjust the vertical scale and offset to display approximately the same amplitude  signals on each channel     5  Select X Y format at Horizontal window  The oscilloscope will displays a Lissajous  pattern representing the input and the output characteristics of the circuit     6  Adjust the scale and offset of the horizontal and vertical to a desirable waveform  display  The following picture shows a typical example     7  Apply the Ellipse Method to observe the phase difference between the two channels     USER   S MANUAL 80    DSO3062L 3062AL  Digital O
49. sor  gt Type     select Horizontal    3  Push left mouse button  and the Horizontal lines appear    4  Drag the mouse button to the point you want to measure    5  Release the left mouse button  the voltage difference will be shown at the status bar     Measure the Amplitude   i    a a a a a a eS ee ae Ce eee ee       Read the details showing in the status bar     Wolt  16 6      Trace the Amplitude of a fixed position on X axis in a Waveform   Do these steps    1  Click    Cursor  gt Source     select CH1  select CH2 if you want trace CH2    2  Click    Cursor  gt Type     select Trace     3  Click the cursor at the position that you want traced of the wave in the waveform  window     USER   S MANUAL 83    DSO3062L 3062AL  Digital Oscilloscope    Trace the Amplitude        Read the details showing in the status bar        Volt   9  454    Note  Click    Cursor  gt Type     select    Cross     you can measure time and amplitude at    one time     USER   S MANUAL 84    DSO3062L 3062AL  Digital Oscilloscope    4 6 Logic Analyzer    Caution  This part is only used for DSO3062AL     Set Bus  Click the menu    Setup     gt     Bus           REF Ctrltk  MATH Ctrl M  Trigger CtrltT  Vertical Ctrlt    Horizontal CtrltH    Trigger Release Ctrlth    inal    Logic Calibrate Data d    DSO3062AL has 16 signals  A0 A15  You can assign parts of them   The user can click the panes E  under the waveform window  If the pane is green  it means  that you have opened it        DO D15 panes    B  
50. splay and measure the  horizontal parameters     USER   S MANUAL 59    DSO3062L 3062AL  Digital Oscilloscope    The Horizontal cursor display window        The Horizontal cursor measure result display on status bar       Volt   3 01      Measure Menu  Click    Measure    in main menu     The oscilloscope provides 20 parametric auto measurements  12 voltage and 8 time    measurements         Aequire Utility    SOLE ie    Yertical    Horizontal      Clear Measure CtritM    1 Source       oe    Vertical d CH   Horizontal d  Clear Measure CtrlitM    The user can use the    Source    menu to select a measure source     USER   S MANUAL 60    DSO3062L 3062AL  Digital Oscilloscope          2  Vertical  ice Acquire Utility   Source     Vertical Maximam   Horizontal   Minimum   Clear Measure Ctrltm Peak to Peak  Top  Base  Middle  EMS  Amplitude  Mean  Cycle Mean    Positive Overshoot    Hegative Overshoot  Maximum  Voltage of the absolute maximum level  Measured over the entire waveform  Minimum  Voltage of the absolute minimum level  Measured over the entire waveform  Peak To Peak  Peak to peak   Max    Min  Measured over the entire waveform  Top  Voltage of the statistical maximum level  Measured over the entire waveform  Base  Voltage of the statistical minimum level  Measured over the entire waveform    Middle  Voltage of the 50  level from base to top    RMS  The Root Mean Square voltage over the entire waveform  Amplitude  Amp   Base   Top  Measured over the entire waveform  Mea
51. the output wave     The Arb  waveform window as the following     a ee    Parameter    Frequency       Generate the Exponent waveform    To output an Exponent Waveform  please do the following steps   1  Press the check box  On Off  to open the wave output function   2  Select the Wave Type  Exponent     3  Set the Wave Parameters     USER   S MANUAL 93    DSO3062L 3062AL  Digital Oscilloscope    Frequency  Set the output wave frequency   Amplitude  Set the output wave amplitude    Y Offset  Set the output wave vertical level offset   Phase  Set the output wave phase    Tao  Set the ouput wave Tao param    Rise  Set the output wave slope     The Exponent waveform window as the following    Parameter  Frequency  Exponent Frequency  1200000Hz   VPKtoPK 4000V O OOOO O  Hz  0   75MHz   Y 035     a E      0 01 0           Generate the White noise waveform    To Generate a White noise Wave  please do the following steps   1  Press the check box  On Off  to open the wave output function   2  Select the Wave Type  White    3  Set the Wave Parameters    Amplitude  Set the output wave amplitude     The White noise waveform window as the following     Parameter    Amplitude       w  0735Y J       USER   S MANUAL 94    DSO3062L 3062AL  Digital Oscilloscope    Synchronized output    If you generate a waveform by software  there is a synchronized signal output from    SYNC     terminal  The signal is square waveform  the frequency of which is equal to the waveform  you generated  For examp
52. waveform number    Operation  Operate    Click    Start    button to start the Pass Fail test     USER   S MANUAL Tf    DSO3062L 3062AL  Digital Oscilloscope    Click    Stop    button to stop the Pass Fail test     The Pass Fail function display       NOTE  Pass Fall function is unavailable in X Y mode     USER   S MANUAL 78    DSO3062L 3062AL  Digital Oscilloscope    4 3 Capturing a Single Shot Signal    To capture a single event  it needs to gather some pre test knowledge of the signal in order  to set up the trigger level and slope correctly  For example  if the event is derived from 3 3V  COMS logic  a trigger level of 1 2 or higher Volts should work on a rising edge  Do these  steps as follows     1  Set the probe and the channel attenuations to X 10    2  Set up the trigger in the Trigger Menu  or in the Trigger Setting window   1  Adjust the Trigger Mode to Edge    2  Set the Trigger Sweep to Single    3  Set the Trigger Source to CH1    4  Set the Trigger Slope to         which means you select the rising edge    5  Adjust the Volts Div and the time base in a proper range for the signal     6  Drag the trigger level sign on the waveform display screen to proper position  It ally  higher a little above the normal level     7  Click START button to start capturing  When the trigger conditions are met  data  appears on the display representing the data points that the oscilloscope obtained with one  acquisition     This function helps to capture the signal occurrence ea
    