Installation & User Manual V2.062
Contents
1. does not store the finger ying tog print It uses an algorithm to generate a binary representation using sample points from the fingerprint It uses this information to then validate each users fingerprint Placement Wi BIO PE EFJ Placement Wi BIO Correct Finger Placement Incorrect Finger Placement Correct Incorrect Note Ensure that the finger is centered and Note Incorrect placement finger does not placed flat to the surface and fully covers the fully cover the sensor window sensor window The door control will not respond and the red light will not turn off if the sensor window Note Finger must remain on the sensor is not fully covered by the finger window until the door control acknowledges that the finger has been scanned by sounding a beep and turning off the red light This will take approximately 1 second
2. un enrolled All Door Controls will have to be defaulted and re enrolled on the new network that has just been created A new network is now ready to be created Go to the Controllers tab and Click on the Wireless Network and then the Create a New Network button Click Yes on the pop up to proceed Note Make sure the USB enrollment reader is not connected to the PC before the application is installed Launch the application A Launch the application by clicking the PC app icon on the desktop B Click Create a new W iPlus Site and give it a name of the new installation site C Log in to the application as the Engineer not the administrator with the password 6666 D Connect to the Controller Refer to page 12 amp 13 for setting up DHCP or Static IP addresses E The Controller icon will change colour to show that the Controller is on ine F Go to the Current Events tab and verify the log messages indicate the controller is on line Note It will take about 20 60 seconds to complete a pop up will appear when the netwrok has been created Operation Instructions peration Instructions fi Phase 3 Enrolling Door Controls Phase 3 Enrolling Door Controls Step Description S Ez Description E All Door Controls should be installed at this point and powered up All Door Controls must be defaulted before joining a network Note Door Controls will be shipped with their factory default settin
3. 10 meters NNN Su Y YIOMION 100g PC Direct Connection can be used when using ONLY one Controller Set the Direct address to ALL dip switches OFF see below Direct Connect All Dip Switches OFF See page 11 on Configuring Controller Communication to setup the application for serial communications ETJ Network Diagrams RS485 Converter a Controller 1 S ax S g S Connect using RS232 RS485 S B N cable to serial port on PC 2 Daisy Chai Set Baud Rate to 19200 paige toler PC Network Connections when using more than one Controller Daisy chain the PC network A B OV to each controller Set an individual address for each controller between 1 amp 3 using the dip switches see below Controller 2 Controller 1 Controller 2 E Controller 3 Address 1 Set SW1 ON Address 2 Set SW2 ON Address 3 Set SW 3 ON Network Diagrams RD Configuring Controller Communications On the Controller tab set the Connection Type to Serial On the Settings tab in the communications section Select the Serial Port number from the drop down list connected to the Controller Direct Connect All OFF Address 1 Set SW1 ON Address 2 Set SW2 ON Note Address 3 Set SW3 ON only To restore the factory default setting Set ALL Dip Swithces 1 2 3 amp 4 to the ON position and then power up the Controller Example All Dip Swithces are set to the
4. ON position Note Factory Default settings will be restored after powering up the controller with All dip swithces ON The dip switchess should then be set to the controller address as shown above in section Setting the controller address Operation Instructions 13 Phase 1 Setting up the Controller Phase 2 Configuring the Controller __ Step Descriptin S Step Description o a Install the main Controller and power up Open the Doors tab in the main menu to add the required number of new doors to be part of this network One door will already be added by default Default the controller immediately via the dip switch settings Click on the button to add new doors to remove doors See instructions on page 11 M ake sure all doors are Enabled and then click Save Important Once powered up and the controller has completed the default the process reset the dip switches to the correct address positions See instructions on page 11 Open the Settings Tab and do a Configuration Download to the Controlle this gives the Controller a clean set of instructions before beginning to enroll doors onto the network This will take approximately 1 minute Follow instructions on the CD provided to install the PC application ARNING A New Network should only be created on first installation Creating a new network will overwrite any existing network information and any enrolled Door Controls will be
5. Other Access Control Products standalone products Also available is a range of fully functional standalone door controls for less complex door management This attractive design with modern aesthetics will complement and building 1 and 2 Door Digital Keypads Proximity Switch Biometric Switch ae an i 35 1 users i gt Access control Installation Instructions FED Door monitoring Manager user fire and intruder alarm interface Installation Diagrams KD Backlighting Tamper o ant 5 amp rela a oor or ior use System Overview K Robust polycarbonate housing with stainless steel keys Mounts onto a standard electrical back box Wiring Diagrams E Network Diagrams E Operating Instructions P Fingerprint Enrollment F Wi Plus Controller Installation amp User M anual vos Simple Secure Access WwWwW argusaccess com Technical Specs W i Plus Controller Current consumption with load max W 135mm D 46mm H 200mm Technical Specs Wi Plus Door Controls Dimensions Flush Mount Features 16 16 16 Doors controlled 10 Us Reporting Facility Yes Challenge Facility Yes Logging Unlimited Input Output M apping CCTV amp Lift control Supports Wireless amp RS485 Networks Automatic Backup Facility Database Encryption Installation Steps Installation Steps Step Description i Page Install the Controller using the Installat
6. S232 cable may be used Max number of Controllers 3 Max cable length 10 meters Max Cable Length 1 4 km Controller 2 3 Controller 1 Door Control 4 Door Control ae 1 Door Control a r Door Control 2 Note Door Controls can be installed within 30 meters of the Controller or within 30 meters of any other Door Control as each Door Control will function as a repeater Each Door Control transmits data to from the Controller These distances are a guideline The actual communication range depends on building shape and Door Control construction methods used 5 10 8 Wiring Diagrams with Fire Alarm PC Network Connection can be used for multiple controllers See page 10 for wiring Use PC Direct I Connections if using a single controller l See page 9 for wiring Wired 485 Networ I Connections A C B O Sounder Outputs OIM N Od VYY NNW YAOMJON 100g 9911q Dd di dOL Ele Ne G Ldi ee Sp Zdi vec Ko Inputs 3V Lithium I di J Fire Alarm Panel Power In 12V Linear Power supply NOTE Common OV from the Fire Alarm Panel and the OV from the Controller to avoid any ground loop issues W hen the fire alarm is activated ie OV removed from IP3 the local door will be opened Network Diagrams ER Network Diagrams for Single Controller DB9 Female Serial Cable Connect DB9 cable to serial port on PC Maximum cable length
7. all Door Controls are enrolled onto the network go back to the Controller application and click the Secure Network button this safeguards the systems if you select another tab on the application this will happen automatically Select each Door on the application and configure individual settings such as Door Name Timed Actions Relay Times Ajar Times Door Option and Alarm Options etc IMPORTANT A timezone must be selected in Timed Actions for one of the options Card and PIN Any Card Card or PIN or PIN only lf all of these are set to inactive then access will be denied for all cards and PINs on that Door Control Example To Enable PIN codes only on a Wi PINGProx Set the Timed Action Card or PIN to Inactive and set the Timed Action PIN Only to All day Every Day This will grant access for PIN codes and deny access for cards and fobs Enable a User by ticking the Enabled box for each User Assign a Name to the User Assign a UserGroup from the drop down menu The Usergroup will determine the access levels for this User Refer to section on page 18 Configuring Access Levels for information on User Groups Assign a Card PIN number and enroll FingerPrints for the User Refer to section FingerPrint Enrolment on page 20 Click Save to transmit these changes to the Controller Phase 5 Configuring Access Levels Step Description SSS O Oo Access Levels are contro
8. gs Enter Engineer mode on each Keypad Door Control in the following way Press X followed by 6666 Enter 55 to default Press the tick to confirm the keypad will now go through the process of defaulting itself The process could take 20 30 seconds The LED will flash once every second when it is complete Repeat the process for all keyoad Door Controls Enter Engineer mode on each Wi Bio Door Control in the following way Enter 6666 Enter 55 to default Scan Finger to confirm the Door Control will now go through the process of defaulting itself The process could take 20 30 seconds The LED will flash once every second when it is complete Repeat the process for all W i Bio Door Controls Enter Engineer mode on each Prox Only Door Control in the following way A Adda programming card to the Door Control by presenting a card twice on power up The security wing must be removed first Present this new programming card to enter Engineer mode Present the programming card again to select Default mode Present any other card once to default the Door Control The process could take 20 30 seconds The LED will flash once every second when it is complete The controller is now ready to allow Door Controls to enroll onto the Network Go to the Controllers tab and Click on the Wireless Network and thenclick the Allow Doors to J oin start the controller scanning for new doors that do not already have an address only D
9. ion Diagrams W ire the Controller using the W iring Diagrams ES Install and wire each Door Control Refer to the Door Control _ M anual for instructions 4 Connect the Controller to the PC using Network Diagrams 9 11 Restoring Factory Defaults Phase 1 Setting up the Ccontroller 6 Coo T E installation Diagrams Installation Diagrams ED 1 To open front cover of Controller remove screw cap using screwdriver then loosen screw 3 screw the rear enclosure to the wall as shown below 2 Remove door from unit see inset before screwing the rear enclosure to the wall To remove front cover lift tab up and unhook door 4 Re attach the front cover To re attach front cover hook door over top pip and rotate into position and push tab down to secure Use for retaining cables Note If using a single Controller an RS232 cable may be used M ax cable length 10 meters Place a120ohm Termination Resisto across A amp B onthe Controller RS485 Network to Controllers M ax number of Controllers 3 M ax Cable Length 1 4 km Controller 2 3 Controller 1 RS485 Network to Door Controls M ax Cable Length 1 4 km Daisy Chain Configuration Only Door Control Door Control Place a 120o0hm Termination Resistor across A amp B onthe last Door Control in the chain Door Control Door Control 3 4 10 System Overview Biya LA Note If using a single Controller RS485 Network to Controllers an R
10. ling User FingerPrints Description E Note M ake sure the USB Fingerprint reader is attached to the PC On the Users Tab Select a User for fingerprint enrollment Click on the Fingerprints button 2 3 Click on button to begin and place finger on the enrolment reader An image of the fingerprint will appear on the screen Ensure that the image quality is good and a value of at least 90 is achieved Refer to section Finger Placement for correct finger placement and example of good quality image Repeat this process if this is not achieved on first attempt Click Save using a good quality template only Poor Quality templates can lead to false rejections later when trying to gain access Placement W i BIO Placement Wi BIO FAD Correct Finger Placement Incorrect Finger Placement Note Incorrect placement finger does not fully cover the sensor window YS coos Quality Image Note Ensure that the core of finger is x P oor Qua lity Im q ge centered on the sensor window during the enrollment process This will increase the quality of the fingerprint template Ensure a value of at least 90 is achieved Note Poor Quality image No Fingerprint core on sensor window Note Good Quality image Fingerprint core REZZAN This can result in poor template quality that is center of sensor window w BON can lead to false rejection issues later when the user is trying to gain access Note The System
11. lled by creating UserGroups and assigning the UserGroup to a User as decribed in section Configuring Users UserGroups are created by combining pairs of DoorGroups with Timezones Each UserGroup can have up to 6 pairs of DoorGroups and Timezones Select DoorGroups and Timezones from the drop down menus to add to the current UserGroup Timezones are the periods of time for each day of the week that access will be granted Select times and tick the days of the week this time is valid 4 time periods can be created for each timezone Select Holiday Access to grant access for holiday periods Double click on the Holiday Access to add days to the holiday periods Use the calender to select these days DoorGroups are created by grouping doors together e g all the entry and exit doors could be grouped together as Peremiter Doors Select a Door from the All availble Doors window and drag it to the Doors in Current Door Group to add it to the Door Group Repeat for adding each door Phase 6 Downloading Configuration Step Description O After all users access levels and door control settings have been finalised a full download to the controller should be carried out Go to the Settings tab and click on Download Configuration A pop up window will appear tracking the status of the download All settings will be downloaded to the Controller and Door Controls Operation Instructions F Enrol
12. oorControls without an address can be enrolled Note For Wired 485 Door Controls right click on the Controller on the right hand side of the application and select Manually Assign Address from the drop down menu Once all new Door Controls are found by the Controller they will all beep with the number of the next available address door position on the Controller e g if door 2 is the next available address then all Door Controls will beep at the same time with 2 beeps This is basically saying that any door can be assigned to this address It s up to the installer to decide which one Also you will notice that the Key back light of the keypad Door Controls will be illuminated with the next available address as well le Key 2 will be illuminated for this example Go to the Door control that you want to make door 2 on the network system it should be beeping 2 times Press any key on this keypad and the system will automatically assign this door control to door 2 address on the system Present a card if the Door Control is Prox Only Note All other Door Controls will now start beeping with the next available address i e 3 beeps address 3 in this instance and so on every time you enroll a new Door Control The Key back light will also correspond to each address as the system fills up Operation Instructions Phase 4 Configuring Users Phase 3 Enrolling Door Controls Step Description S L Once