Home
User Manual
Contents
1. ly ACA d Fig 2 Do not open any part of the luminaire without disconnecting line voltage The luminaire is to be used in Zone 1 Zone 2 or Safe Area WARNING The luminaire can only be installed in Zone 1 and Zone 2 if equipped with ATEX and IECEx approved cable glands and blind plugs Rubber seal and cable glands Be sure to install the cable in a way whhich prevents water to penetrate into the enclosure through the cable gland Also make sure to use the correct rubber seal when you install the cables into the luminaires Cable diam Size Part No 12 0 15 0mm 26 8 15 0x10mm 5002 0140 15 0 20 1mm 26 8 20 3x10mm 5002 0139 SPARE PARTS Description Lamp insert complete 230 VAC Lamp insert complete 120 VAC Lamp insert complete 24V DC Fluorescent tube 7W G23 Fluorescent tube PLC 10W 827 4 pins 24V Cable gland Exe M25 Includes two rubber seals for cables 12 20m Reactor 230VAC Reactor 120VAC Electronic reactor for 24 VDC revision Part No 1671 3059 3191 9400 032 9400 071 6222 502 5086 0035 5086 0031 5028 0049 TEF 2430 LUMINAIRE USER MANUAL Terminal block Wago 5028 0008 Terminal block with brass plate 4128 Lamp holder for PL C 13W 120VAC 5088 0030 Lamp holder G23 for PL S 7W 230VAC 5088 0031 Lamp holder G24q for PL C 13W 24VDC 5088 0034 Globe with guard yellow amber 2036 Globe with guard clear 1223 Globe with guar
2. TEF 2430 IECEx Ex de LUMINAIRE USER MANUAL IMPORTANT Read this instruction carefully before installing the product L D Co 7 M REV E 14 10 2014 TRANBERG Tranberg AS P O Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com TUM 2373 TEF 2430 LUMINAIRE USER MANUAL INTRODUCTION APPROVAL Thank you for purchasing this product Ex Explosion category Il 2 G Ex de IIB Gb T5 For installation maintenance and assurance of a long life of ATEX IECEx this product please follow this manual Ex de IIB T5 Canada Class Zone 1 AEx de IIB T5 US LICATION Certificate No IECEx NEM 13 0016X ee Nemko O3ATEX064X amp 216432 e Deck lighting e Signal lighting Approved for use in Zone 1 Zone 2 and Safe Area Pesta neunng Marking CE 0470 Il 2 G Ex de IIB Gb T5 e Perimeter lights on helideck Ex de IIB T5 Class Zone 1 AEx de IIB T5 CONTENT IN BOX Notified body Nemko AS Norway CSA International Canada INSTALLATION INSTRUCTIONS Only qualified personnel are allowed to perform installation and maintenance tasks to
3. and Starter Holders for Fluorescent Lamps UL 935 2001 Tenth Edition UL Standard for Safety For Fluorescent Lamp Ballasts ANSI UL 60079 0 2002 First Edition Electrical Apparatus for Explosive Gas Atmospheres Part 0 General Requirements ANSI UL 60079 1 2002 First Edition Electrical Apparatus for Explosive Gas Atmospheres Part 1 Flameproof Enclosures d ANSI UL 60079 7 2002 First Edition Electrical Apparatus for Explosive Gas Atmospheres Part 7 Flameproof Enclosures e TRANBERG Tranberg AS PO Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com
4. d green 1224 Globe with guard red 1225 Globe with guard yellow 1226 Globe with guard blue 1227 Gasket o ring for globe 107 5 3 53 nitrile 5000 8009 TECHNICAL DATA Material Cast copper alloy Globe polycarbonate Lexan Junction box in AISI 316L Supply Input voltage 24 VDC 120VAC 60Hz 230VAC 50 60Hz T rating T5 IP protection IP66 67 Power consumption Max 20 Watt Light source PL S 2x7W 230 VAC PL C 13W 120 VAC PL C 10W 24 VDC 15W Compact fluorescent integrated only for ATEX approval not for CSA approval Tamb 30 C to 45 C Arctic version 55 C to 45 C Weight 6 kg Compliance with CENELEC EN 60079 0 2013 CENELEC EN 60079 1 2007 CENELEC EN 60079 7 2007 CSA Standard C22 2 No 0 M 91 General requirements Canadian Electrical Code Part II CSA Standard C22 2 No 0 4M 1982 Bonding and Grounding of Electrical Equipment Protective Grounding CAN CSA Standard C22 2 No 43 M 1984 Lampholder CAN CSA Standard C22 2 No 250 0 00 Luminaires CAN CSA E60079 0 02 Electrical Apparatus for explosive gas atmospheres Part 0 General Requirements CAN CAS E60079 1 02 Electrical Apparatus for explosive gas atmospheres Part 1 Flameproof Enclosures d CAN CAS E60079 7 02 Electrical Apparatus for explosive gas atmospheres Part 7 Increased safety e UL 1598 2000 First Edition UL Standard for Safety Luminaires UL 542 1999 Eight Edition UL Standard for Safety For Lampholders Starters
5. e mounted on the same surface as the lamp housing bracket a full and rigid e Tools for mounting e g 13 mm wrench to fasten the pin on the guard ring e Flat head screwdrivers approx 3 5 mm for connect support must be provided for the junction box An unsup ing to terminal block and 8 0 mm for junction box lid ported junction box may be damaged if stepped upon earth screw Likewise an unsupported junction box that is forced down by e g a pull of electrical cables may expose the gasket 2 h to di le the bli d oe Tani Ene oleae ela ic une Rgier between the junction box and lamp housing assemble the cable gland J Do not use excessive force when tightening the four screws e 25mm wrench for tightening the pressure nut onthe on the junction box lid and never use a power screwdriver cable gland Excessive force may bend the lid and provide a way for wa ter to enter the junction box When closing the lid on the MAINTENANCE INSTRUCTIONS junction box please ensure that no electrical wires or the o safety wire to the lid itself are jammed between the lid and The luminaire should be inspected according to Company the junction box routines The manufacturer suggests regular check for water intrusion condensation which should be removed Not following these instructions may lead to a risk of water immediately ingress into the luminaire The manufacturer assumes not When cleaning use only mild detergents A
6. lcohol or responsibility when these guidelines are not followed petroleum based products may damage lens paint or plastic components When cleaning the dome use moist cloth to avoiding electrostatic hazard The terminal block of this luminaire is of the cage clamp type and one needs either special tool or just a small flat head screwdriver to connect the cable to terminal block The cable glands are approved for a specific cable diameter TEF 2430 LUMINAIRE USER MANUAL These data can be found in the certificate of the ATEX ap proved cable glands Make sure this is not violated Use of cable with other dimensions is a safety violation and should be avoided Any damage caused by use of incorrect cable gland not matching the cable dimension is not the respon sibility of Tranberg AS and is not covered by warranty Max cross section of the cable to be connected to the terminal blocks is 2 5 mm To connect the wiring of the TEF 2430 luminaire perform the following procedure Remove the cover from the junction box Connecting cable for 230 120 VAC The main power 230 120 VAC is to be connected to the terminal blocks marked 11 and 22 see fig 2 Connecting cable for 24 VDC Compact fluorescent lamp The main power 24 VDC is to be connected to the termi nal blocks marked and see fig 2 The 24 VDC version not to be grounded Make sure electrical connections are safe and reliable Make sure the wire slack is a
7. s needed Reinstall the cover If properly mounted and installed the luminaire is now ready for use Replacement of lamp Deactivate the input power Remove the unlock safety pin marked as 1 in fig 3 Remove the ring with globe and guard marked 2 in fig 3 and replace the lamp If necessary lubricate the threads with grease Renolit Unitemp 2 from Fuchs Reinstall the ring with globe and guard and fasten the safety pin Troubleshooting No light Check main power connections to the terminals blocks or lamp If the light still does not function contact the nearest Tranberg dealer or Tranberg AS directly Safety precautions Note that changes made to this product and or installa tion of components which do not conform to the approval may be a safety violation The manufacturer will under no circumstances be held responsible for personal injuries death or any damage caused by such activity For your health and safety always use safety gear suited for the task and follow company guidelines and all relevant rules and norms for installation where applicable Fig 1 a
8. this equipment The product is fully assembled and ready for installation SAFETY PRECAUTIONS Note that changes made to the product and or installation The equipment is ready for installation when leaving the of components which do not conform to the approval production facilities of Tranberg AS Check the condition of may be a safety violation The manufacturer will in no the equipment and the contents when unpacking Any dam circumstance be held responsible for such activity age done to the equipment during the transportation is not For your health and safety always use safety gear suited the responsibility of Tranberg AS If the content is not com for the task Be certain to follow codes regulations and or plete file a claim to the manufacturer immediately specific procedures that are related to the installation The TEF 2430 is mounted ona briecket which have caver mounting choices using 2 pcs of M8 max bolts and nuts or a 2 pipe The dimensions of the mounting bracket are TOOLS REQUIRED shown in fig 1 Important when mounting the luminaire Regular tools required for installation The luminaire must always be installed in such a way that 4 the junction box is fully supported from underneath Nor luminaire mally the entire luminaire would be installed to a flat sur e 3mm hexagon key Unbrako for lock unlock safety face which provides a proper support for the junction box In cases where the junction box cannot b