CIRRUS Series Counters User`s Manual

image

Contents

1. respectively 3 1 DIP SWITCH PROGRAMMING 3 1 1 LEFT DIP SWITCH Pins 1 2 and 3 the first three DIP switches define how the input count signals Input 1 and Input 2 will be read Determine which of the six available settings in needed for your application and set the switches accordingly LEFT SWITCH INPUT COUNT TYPE Single and Bi directional Counter 2 3 Input 1 Count signal Input Directional Signal Counter will count the trailing edges of input 1 UP UP UP Counter will read a positive count when Input 2 is LOW and will read a negative count when Input 2 is HIGH Quadrature Counter Input 1 Quadrature Count Signal Input 2 Directional Signal Input 1 will count the trailing edges of the input signal DN UP UP If Input 2 trails the Counter will read a positive count If Input 2 leads the Counter will read a negative count Quadrature Count x 2 Input 1 Quadrature Count Signal x 2 Input 2 Directional Signal The leading and trailing edges of Input 1 are counted UP DN UP If Input 2 trails the Counter will read a positive count If Input 2 leads the Counter will read a negative count Quadrature Count x 4 Input 1 Count Signal x 2 Input 2 Directional Count Signal x 2 Same as Quadrature Count x 2 except that the leading DN DN UP and trailing edges of the Input 2 are also counted Count with Inhibit Input 1 Count Signal Input 2 Halts Input 1 counting when active Counter will coun
2. OFF at Preset to 99 99 sec Latched ON In addition the outputs can also be set to turn OFF upon reaching the preset for the other output in the Dual Preset Model Scale Factor A Prescale value can be set to allow viewing and setting counts using real units of measure The Prescale value is a multiplier which is applied to the count input s to determine the count display and preset values The Prescale value can be set from 0 00001 to 9 99999 In addition the decimal point can be set on the display to any one of 6 positions 2 0 OPERATION To operate the Counter there are four push button keys located on the front of the unit These buttons are provided to allow the user to select change and save various values These key operations are dependent on the DIP Switch settings of the unit see Section 3 0 This figure shows the front of the panel with the Process Count value displayed Pressing SELECT will scroll 100 04 through a menu of options After one of these options is displayed for a second the value for that option is automatically displayed Pressing the lt key will move preset 1 preset 2 ENTER CANCEL Process Count are Totalizer Counts accumulated since last Totalizer Reset When the total counts exceeds 99 999 999 the Totalizer display will blink Pressing RESET will scroll through the actual value until pressing RESET a final time will reset the value to Z
3. UP The Counter continues to accumulate counts after the preset is reached or past zero Count and Stop DN The Counter stops accumulating counts after the high preset is reached or at zero 3 1 2 RIGHT DIP SWITCH Pin 1 determines whether the Counter will automatically reset or not Auto Reset Off UP The Counter will not automatically reset Auto Reset On DN The Counter will automatically reset upon reaching the high preset or zero The reset will occur either immediately or after the Timed Output value has elapsed See RIGHT SWITCH Pin 2 Note Auto Reset does not apply to the Batch Counter when in Batch Counting Mode Refer to Section 7 0 for addition information on Auto Reset Pin 2 determines when the Auto Reset will occur RIGHT SWITCH Pin 1 must be set DOWN Auto Reset On The Counter will automatically reset after the high Heset at Preset UP preset is reached or at zero The Counter will continue counting after the high Reset at Time out DN preset is reached or at zero until the Timed Output value has elapsed and then will automatically reset Pin 3 determines if the Totalizer Counter is active Totalizer Off UP The Totalizer is disabled Totalizer ON DN The Totalizer is enabled and will count all pulses into the unit The Totalizer can be reset by displaying the Totalizer value on the display and pressing the Reset button Pin 4 sets the Dual Preset Model to DUAL PRESET or BATCH M
4. 99 98 Output 2 T2 0 5 sec with Auto Reset Range 5 with AR 0 01 to 99 98 Latched This is the only way to Auto Reset the Batch Count PROCESS 16 12 8 A 16 12 8 4 16 wu wu2 S LULILILILU LI LHPELI 1 lt BATCH AUTO RESET OUTPUT 1 P1 1 0 OUTPUT 2 BATCH P2 15 10 0 ORDERING INFORMATION BASIC MODEL TYPE ee PRESETS SP Single Preset DP Dual Preset w Batch VOLTAGE FREQUENCY 120 120 VAC 50 60 Hz 240 240 VAC 50 60 Hz OUTPUT TYPE NPN NPN Transistor RLY Relay FEATURES NONE Standard X Special 11 0 AWORD ABOUT SAFETY Most of FSl s products are designed for general and not for specific applications Because of this we usually are not aware of how they eventually will be used However they are frequently employed in controlling automatic machinery or processes Although FSI makes products of high reliability every product given enough time can be expected to fail Statistically devices can fail after a short period of time or a long period of time or anything in between In essentially all cases failure means 1 failure to provide a logic signal or power to an electrical load when it should or 2 the providing of such a signal or power when it should be absent Less often failure means failure to meet some other specification But in all cases it means to do something unwanted or unexpected Since the failure of automatic machinery or proc
5. 75 V Min Debounce reduces count Input 1 to 100 Hz Input 2 no debounce Interval start requires 15 msec min pulse Can be momentary or sustained 10 Remote Resets Count Batch Totalizer Min 15 ms pulse Pulled to 5V via 8K ohm res Active Low ViL 0 5 V Max Max current 625 ma Output Solid State Current Sinking sink 100 ma Max VoL 1 0 VDC Max Max Voltage 30 VDC Output Relay Life 100 million operations no load Contact Rating 10 amp 30 VDC or 250 VAC 1 3 HP DC supply for external sensors 12 VDC Regulated 4 Max current 120 ma Memory Non Volatile EEPROM 196 000 power losses min 10 Year Retention Models Single and Dual Preset with either NPN Solid State or Relay Outputs Power 120 VAC 95 132 VAC 240 VAC 190 264 VAC 50 60 Hz Max power 8 VA Display 8 Digit 14 Segment 5 mm X 4 1 mm 0 2 x 0 16 Blue Vacuum Fluorescent Housing Plug in 72 mm sq DIN Plug in Fully Gasketed Dust and Water tight Terminals 16 screw terminals accessible from rear Operating Temperature 0 F to 140 F 20 C to 60 C Humidity 0 to 80 RH Non condensing 6 0 CONTROLLING OUTPUTS 6 1 SINGLE PRESET COUNTER Time Delayed Output To make the output remain energized for a time delay set the Output 1 value to a time value This time value can be set to a range of 00 01 to 99 98 seconds Upon reaching the preset the output will
6. ESET ON PWR UP UP HIGH THRESHOLD IN UP NO PANEL RESET DN LOW THRESHOLD IN DN PANEL RESET UP NO DEBOUNCE INPUT UP NO ACCESS T1 T2 SF DP DN DEBOUNCE INPUT DN ACCESS T1 T2 SF DP UP SINK INPUT SIGNAL UP NO ACCESS P1 P2 DN SOURCE INPUT SIGNAL DN ACCESS P1 P2 UP COUNT UP UP DUAL PRESET MODE DN COUNT DOWN DN BATCH MODE UP COUNT AND GO UP TOTALIZER OFF DN COUNT AND STOP DN TOTALIZER ON Bold indicates factory default setting UP AUTO RESET AT PRESET DN AUTO RESET AT TIME OUT UP AUTO RESET OFF DN AUTO RESET ON NOTES RIGHT SWITCH Pin 4 DUAL PRESET BATCH MODE is only active on Dual Preset Models RIGHT SWITCH Pin 2 AUTO RESET AT PRESET TIME OUT is active only when RIGHT SWITCH Pin 1 is set to AUTO RESET ON DN The automatic reset takes place after the Preset or zero is reached depending on the setting of LEFT SWITCH Pin 7 COUNT UP DOWN and will occur either immediately at the Preset or after the Timed Output value has elapsed For Dual Preset Mode the automatic reset occurs after the highest of the two presets has been reached For Batch Mode the automatic reset only applies to Preset 1 Count preset For automatic reset of Preset 2 Batch preset in Batch mode refer to Section 6 3 2 Changing the RIGHT SWITCH Pins 1 2 amp 4 and LEFT SWITCH Pins 1 2 amp 3 may cause the counter to load the default P1 P2 T1 T2 SF and DP values of 500 1000 00 01 00 01 1 00000 and
7. Encoders Controls Sensors COMMITTED TO INNOVATION QUALITY PERFORMANCE CIRRUS Series Counters User s Manual HISTORY Founded in 1959 FSI Technologies Inc Had its beginnings in the design and manufacture of precision tuning fork time standards primarily for use in military applications In the mid 1960 s FSI entered into the industrial market with a line of high performance logic compatible photoelectric sensors and controls for factory automation During the following years FSI continued development of its sensor line while branching into high speed IR sensors optical rotary shaft encoders machine vision fiber optics and other leading edge sensor and control technologies Presently FSI manufactures state of the art sensors and electronic products for use in industrial commercial military and medical applications IN HOUSE CAPABILITIES standard sensors amp encoders Custom sensors amp encoders Application engineering amp testing Electrical amp mechanical engineering Prototype amp production machining Darkroom amp technical graphics Prototype PCB etching amp fabrication PBC amp mechanical assembly The above capabilities and a creative quality conscious staff make FSI the company of choice for both standard and custom products FSI is committed to innovation quality and customer satisfaction All of us at FSI and our capable network of Distributors look forward to assisting you Please call fo
8. NPUT SIGNAL Sink Input Signals Left Switch Pin 6 UP QUADRATURE OUTPUT COM F ENCODER 12VDC AUX AUX PWR PWR COM MOUNTING AND DIMENSIONS PANEL CUTOUT SHOWING DISTANCE INCHES BETWEEN ADJACENT CUTOUTS MILLIMETERS 1 10 3 63 MN 2 83 eae 92 20 CO 7200 7 2799 gm T EM 67 00 SQ 5 0 CIRRUS SPECIFICATIONS Settings Front Panel Presets 1 to 999 999 Scale Factor 0 00001 to 9 99999 Timed Outputs 00 01 to 99 98 sec Latched Off at Preset Decimal Positions 0 to 6 Count Input Modes Switch Selectable Bi Directional Quadrature X1 Quadrature X2 Quadrature X4 Count with Inhibit Interval with Start Input Operating Features Switch Selectable Count Up or Count Down Count Go or Count Stop Sink or Source Count Input High or Low Threshold Bias Auto Reset at High preset Count Up Zero Count Down After Timed output Totalizer Dual Preset Batch mode Security lockout Access to Presets Access to T1 T2 SF DP Front panel Reset Reset on Power Up Maximum Counting Frequency 10 kHz Count Up mode 9 kHz Count Down Mode Reduce by 3 kHz when Totalizer Counter is enabled Reduce by 2 kHz when Auto Reset is enabled Min pulse 10 usec on 90 usec off Count Inputs Sink 9 4 K ohm pull up Max current 1 25 ma Source 4 7 K ohm pull down Max voltage 30 VDC 7 ma High Bias ViL 5 5 V Max ViH 7 5 V Min Low Bias ViL 1 5 V Max ViH 3
9. ODE this switch is not active on Single Preset models Dual Preset Mode UP In the Dual Preset Mode Preset 1 is the Preset for Output 1 and Preset 2 for Output 2 Batch Mode DN In the Batch Mode Preset 1 is the target Count value for Output 1 and Preset 2 is the number of cycles that will occur in the Batch process before Output 2 switches Pin 5 establishes operator access to Preset 1 and Preset 2 No Access P1 P2 UP This prevents access to these Presets from the front panel during operation Access P1 P2 DN This allows the Preset values to be adjusted from the front panel during operation Pin 6 establishes operator access to the values of Timed Output 1 Timed Output 2 Scale Factor and Decimal Point position No Access T1 T2 SF DP UP This prevents access to these values from the front panel during operation Access to T1 T2 SF DP DN This allows these values to be adjusted from the front panel during the process Pin 7 determines whether the Reset Key on the panel is active during operation No Panel Reset UP The count can not be reset by pressing the Reset Key on the panel Note the three hardware reset terminals are always active and are not affected by this setting Panel Reset DN The displayed Count Batch or Totalizer value will be reset when the Reset Key is pressed Pin 8 determines whether the Counter will reset when power is lost No Reset on Power Up UP The Counter
10. activated when Preset 1 is reached and Output 2 is activated when Preset 2 is reached Count Down from a Preset to Zero When Reset is pressed the Counter is set to the Preset value When the Count value equals zero the Output is activated In the Dual Preset Model the Counter counts down from the High Preset value and activates one Output when it reaches the Low Preset value the other Output is activated when the Counter counts down from the Low Preset value and reaches zero Interval Mode In this mode the Counter will not begin counting until Input 2 is turned ON indicating a Start Signal Once the Start Signal is received the Output will turn ON and the Counter will count The Output will then turn OFF at the preset or zero The Start Signal must be activated each time the process is reset even when the Counter is set to Auto Reset Batch Mode Dual Preset Models only In the Batch Mode Input 1 is the Count input and will turn ON at Preset 1 Each time Output 1 turns ON the Batch Counter will record a count When the Batch Counter value equals the value in Preset 2 Output 2 will turn ON The Batch Mode must be Manually Reset unless T2 is set to 5 W AR 00 00 for Auto Reset Timed Outputs The Outputs can be delayed before turning OFF by setting time delay values for each output Once the Preset is reached a time delay according to the time value set will occur before the Outputs turn OFF This value can range from 0 00 sec
11. ero Batch Number of cycles elapsed in Batch Mode Preset 1 Preset 2 Value compared with the actual count When the Preset value is displayed the Preset LED on the panel will light indicating which preset is displayed Prescale This factor will scale the input counts The count signal is multiplied by the prescale value range 0 00001 to 9 99999 to determine the count displayed Note If the prescale value is fractional the output will energize when the count value passes the preset value Output 1 Output 2 Time delay setting for outputs Decimal The number of decimal positions for the display When the Counter reaches its presets the output will activate and the LEDs on the panel will flash indicating which output is activated one digit to the left and the key will increment the value by one The SELECT key must be pressed to save SELECT lt A RESET the new value Pressing RESET will return to the process count display The change will not be entered if SELECT is not pressed Selections in addition to 00099898 000500 1 00000 LATCH E D 3 0 DIP SWITCH SETUP GUIDE To set up the Counter for operation a series of DIP switches located inside the unit must be set UP or DOWN To access these DIP switches loosen the two screws on the front panel and pull the unit from its housing LEFT SWITCH RIGHT SWITCH 1 2 3 4 5 6 7 8f 1 2 3 4 5 6 7 8 INPUT COUNT TYPE UP NO RESET ON PWR UP See next page DN R
12. esses can create hazardous conditions for personnel or property whatever the definition of failure might be it is necessary to consider the consequences of failure and design the application in which the FSI product is used so that failure will not create a hazard to personnel or property The design must insure that any failure will result in a fail safe condition and there will be no danger to personnel and or property involved in the use of the product FS products are not intended for use as final safety devices Designs incorporating controls of any kind should be carefully considered to provide for their eventual failure IMPORTANT NOTICE The use of this product is beyond the control of the manufacturer no guarantee or warranty expressed or implied is made as to such effects incidental to such use handling or possession or the results to be obtained whether in accordance with the directions of the claimed so to be The manufacturer expressly disclaims responsibility therefore Furthermore nothing contained herein shall be construed as a recommendation to use any product in conflict with existing laws and or patents covering any material or use Warranties of Sale disclaimer thereof and limitations of liability are covered exclusively by FSIs printed warranty statement for controls These instructions do not expand reduce modify or alter FSIs warranty statement and no warranty or remedy in favor of a customer or any other person ari
13. he Counter to operate with repeating cycles without waiting for a manual reset signal from the Reset key on the panel or the external Count Reset input Note Auto Reset will only reset the Process Count value The outputs will remain ON until the Output time delay has elapsed Auto Reset does not affect the Batch Count To Auto Reset the Batch Count refer to Section 6 3 2 Note When the Counter is set to Auto Reset the maximum count frequency is reduced by 2 kHz 8 0 CALCULATING THE SCALE FACTOR The Prescale value is factory set to provide 1 count on the display for each input pulse received by the Counter To make the display show real units such as gallons or feet set the prescale value to calculate these units for the display The Prescale value is determined as follows PRESCALE VALUE DISPLAY UNITS NUMBER OF PULSES The DISPLAY UNITS represents the number of units that should be displayed after the NUMBER OF PULSES has been counted The NUMBER OF PULSES is the number of pulses required to achieve the DISPLAY UNITS The Prescale value can be set from 0 00001 to 9 99999 13 9 0 EXAMPLE COUNT DIAGRAMS 9 1 COUNT UP MODE DUAL PRESET MANUAL RESET NO OUTPUT DELAY LEFT SWITCH RIGHT SWITCH 20 p 2 sjsjsje rje sy2 s ajsjo r e Preset Values Low Preset P1 Range 1 to 999 999 High Preset P2 Range 1 to 999 999 Output 1 T1 p Range Off at P2 0 01 to 99 98 Latched Out
14. lso the Latched output setting is not active when the Counter is set for Interval Mode To latch either output ON until the Counter is reset set the Output 1 and or the Output 2 value to 99 99 The display will show LATCHED Upon reaching the preset the output will remain ON until it is reset via the Reset key on the panel or the external Count Reset input Output ON at Low Preset OFF at High Preset To make the output controlled by the lower preset turn OFF at the higher preset set the Output value of the output controlled by the lower preset to 00 00 If Output 1 has the lower preset the Output 1 value display will show OFF AT P2 If Output 2 has the lower preset the Output 2 value display will show OFF AT P1 If the Counter is set to Count Down the output value display will show OFF AT 0 Upon reaching the Low Preset the output will remain ON until the High Preset is reached or until it is reset via the Reset key on the panel or the external Count Reset input 11 6 2 DUAL PRESET COUNTER continued Output OFF at Preset Note The Counter must be set to Interval Mode for the OFF at Preset setting to be allowed To make either output turn OFF upon reaching the preset set the Output value to 00 00 The display will show OFF at P1 for Output 1 or OFF at P2 for Output 2 If the Counter is set to Count Down the display will show OFF at 0 Upon reaching the preset the output will turn OFF 6 3 BATCH COUNTER 6 3 1 Outp
15. nd the Counter is set to Auto Reset RIGHT SWITCH PIN 1 DN The maximum count frequency is reduced by 4 kHz 12 7 0 RESETTING THE COUNTER 7 1 Manual Reset The Counter can be manually reset via the Reset key on the panel or via the external Reset inputs Pressing the Reset key on the panel will reset the Counter which is currently displayed on the panel To reset the Process Counter press the Reset key when the Process Count is being displayed To reset the Batch Counter press the Reset key when the Batch Count is displayed To reset the Totalizer press the Reset key when the Totalizer Count is displayed The three external Reset inputs will reset the Process Batch or Totalizer Counters when activated Reset of the Counters will occur within 15 msec of a signal being received by the Reset key on the panel or from the external Reset inputs Upon reset the appropriate outputs will turn OFF and the Counter will be reset to zero or the high preset for count down mode The Counter will not read count inputs while the reset signal is being received When the reset signal is removed the Counter will again begin to count 7 2 Auto Reset RIGHT SWITCH PIN 1 DN Auto Reset allows the Counter to automatically reset upon reaching the high preset or zero for count down The Auto Reset will occur either immediately at the high preset or after the Output time delay has elapsed depending on the position of RIGHT SWITCH PIN 2 This allows t
16. put 2 T2 2 Latched Range 0 01 to 99 98 Latched PROCESS 0 1 2 3 4 5 6 8 9 wu UI LUILIU LYE LI LI LI O OUTPUT LOW MANUAL RESET gt OUTPUT HIGH 9 2 COUNT DOWN MODE DUAL PRESET AUTO RESET AFTER TIME OUT LEFT SWITCH RIGHT SWITCH 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Preset Values Low Preset P1 3 High Preset P2 5 Output 1 T1 2 0 Range 1 to 999 999 Range 1 to 999 999 Range Off at Zero 0 01 to 99 98 Range 0 1 to 99 98 SS NN Output 2 T2 4 0 PROCESS 5 4 3 2 1 0 1 2 5 4 wr SUMMIT UT Mr un AUTO RESET gt OUTPUT LOW 71 20 OUTPUT HIGH T2 4 0 14 9 3 INTERVAL MODE COUNT DOWN MODE DUAL PRESET MANUAL RESET LEFT SWITCH RIGHT SWITCH E ieee ee a p a2 sjsjsje rje sy2 sjejsjo r e Preset Values Low Preset P1 High Preset P2 Output 1 T1 Off A 1 Range Off at P1 0 01 to 99 98 Range 1 to 999 999 Range 1 to 999 999 Output 2 T2 Off at O Range Off at 0 0 01 to 99 98 PROCESS 5 1 4 3 2 1 0 1 START SIGNAL MANUAL RESET START SIGNAL 9 4 QUADRATURE x 4 COUNT DOWN MODE BATCH MODE BATCH AUTO RESET LEFT SWITCH RIGHT SWITCH e e 1 2 31415 7 8 1 2 3 4 5 Preset Values Count Preset P1 16 Range 1 to 999 999 Batch Preset P2 2 Range 1 to 999 999 Output 1 T1 0 5 Range 0 01 to
17. r the location of your nearest Distributor 630 932 9380 FAX 630 932 0016 800 468 6009 668 Western Ave Lombard IL 60148 2097 Email info fsinet com Table Of Contents Section Page Introduction 1 0 2 Operation 2 0 3 Dip Switch Setup Guide 3 0 4 Dip Switch Programming 3 1 5 Wiring Mounting and Dimensions 4 0 8 Cirrus Specifications 5 0 10 Controlling Outputs 6 0 11 Single Preset Counter 6 1 11 Dual Preset Counter 6 2 11 Batch Counter 6 3 12 Resetting the Counter 7 0 13 Calculating the Scale Factor 8 0 13 Example Count Diagrams 9 0 14 Count Up Mode 9 1 14 Count Down Mode 9 2 14 Interval Mode 9 3 15 Quadrature x4 Mode 9 4 15 Ordering Information 10 0 16 Safety 11 0 16 1 0 INTRODUCTION The Cirrus Series Counter is a predetermining counter that will count high speed unidirectional bi directional or quadrature input signals and will activate an output when the predetermined preset value is reached The unit is available in both Single and Dual Preset models and includes an internal totalizer Also the Cirrus Counter will operate as a Batch Counter using the second preset as a Batch Preset The Cirrus comes with a variety of counting modes some of which are only available in the dual preset model The counter allows the users to set Count Up from Zero to a given Preset The Output in the Counter is activated when the Count equals the Preset In the Dual Preset Model the Counter counts up from zero and Output 1 is
18. remain ON for this period of time or until it is reset via the Reset key on the panel or the external Count Reset input Latched Output Note Auto Reset must be set OFF for the Latched output setting to be allowed RIGHT SWITCH PIN 1 UP Also the Latched output setting is not active when the Counter is set for Interval Mode To latch the output ON until the Counter is reset set the Output 1 value to 99 99 The display will show LATCHED Upon reaching the preset the output will remain ON until it is reset via the Reset key on the panel or the external Count Reset input Output OFF at Preset Note The Counter must be set to Interval Mode for the OFF at Preset setting to be allowed To make the output turn OFF upon reaching the preset set the Output 1 value to 00 00 the display will show OFF at P1 If the Counter is set to Count Down the display will show OFF AT 0 Upon reaching the preset the output will turn OFF 6 2 DUAL PRESET COUNTER Time Delayed Output To make either output remain energized for a time delay set the Output 1 and or the Output 2 value to a time value This time value can be set to a range of 00 01 to 99 98 seconds Upon reaching the preset the output will remain ON for this period of time or until it is reset via the Reset key on the panel or the external Count Reset input Latched Output Note Auto Reset must be set OFF for the Latched output setting to be allowed RIGHT SWITCH PIN 1 UP A
19. ses out of these instructions 16 Over 750 Distributors within North America to Serve You Techno ogles 668 Western Avenue Lombard IL 60148 2097 ph 800 468 6009 fax 630 932 0016 sales fsinet com www fsinet com Machine Vision TM Encoders Controls Sensors 2006 FSI Technologies Inc All rights reserved Bulletin 2952 8600 31 Printed in U S A by FSI Press
20. t the trailing edges of Input 1 and read UP UP DN positive counts only when Input 2 is OFF When Input 2 is ON no counts are read Interval Mode Counter with Start Signal Input Input 1 Count Signal Input 2 Start Signal The Outputs will turn ON when Input 2 Start Signal is DN UP DN turned ON Counter will count the trailing edges of Input 1 and register positive counts only after the Start Signal is detected When the Preset s are reached and Timed Output values have elapsed the Outputs will turn OFF Pin 4 determines the threshold level for the Input Signal is High UP 5 5 V amp 7 5 V trigger levels Proximity Switch Low DN 1 5V amp 3 75 V trigger levels TTL Pin 5 determines if the signals from Input 1 are filtered before being counted No Debounce UP oignal is unfiltered with a max freq of 10 kHz Debounce DN Signal is filtered to a max freq of 100 Hz Pin 6 determines whether the Inputs 1 and 2 operate as Sinking UP Max Current 1 25 mA sourcing DN Max Voltage 30 VDC 9 7 mA Pin 7 determines the counting mode of the device Count Up Mode UP The input will count up from zero and the output s will switch at their preset values s Count Down Mode DN The input will count down from the high preset and the output will switch at zero For Dual Preset Mode the other output will switch at the low preset Pin 8 determines the status of the Process Counter Count and Go
21. ut 1 Process Counter When the Counter is set up as a Batch Counter Output 1 operates the same as the single Preset Counter Refer to Section 6 1 for operation of this output 6 3 2 Output 2 Batch Counter Time Delayed Output To make Output 2 remain energized for a time delay set the Output 2 value to a time delay value This time value can be set to a range of 00 01 to 99 98 seconds Upon reaching Preset 2 Batch Preset Output 2 will remain ON for this period of time or until it is reset via the Reset key on the panel or the external Batch Reset input Latched Output To latch Output 2 ON until the Batch Counter is reset set the Output 2 value to 99 99 The display will show LATCHED Upon reaching Preset 2 Batch Preset Output 2 will remain ON until it is reset via the Reset key on the panel or the external Batch Reset input Pulse for 5 sec and Automatically Reset the Batch Counter To make Output 2 turn on for 5 seconds and automatically reset the Batch Counter upon reaching Preset 2 Batch Preset set the Output 2 value to 00 00 the display will show 5 W AR Upon reaching Preset 2 Batch Preset Output 2 will turn ON for 5 sec and the Batch Counter will automatically reset allowing inputs for the next batch to counted This allows the Batch Counter to automatically repeat its cycle without being manually reset via the Reset key on the panel or the external Batch Reset input Note When Preset 2 is to 5 W AR a
22. will resume counting from where it was before the power loss Note any Outputs that were ON before the power loss will be set to OFF when power is restored Reset on Power Up DN If power is lost the Counter will reset when power is restored 4 0 WIRING MOUNTING AND DIMENSIONS TERMINALS 13 12 L OUT1 12 VDC L2 AUX PWR 2 3 OUTPUT WIRING NPN TRANSISTOR Open Collector COUNT INPUT WIRING SINK INPUT SIGNAL Left Switch Pin 6 UP Counter will read positive counts with terminal 6 not connected For negative counts connect terminal 6 to terminal 15 For Count Inhibit or Interval Mode Start wire terminal 6 in the same manner as terminal 5 4 0 WIRING MOUNTING AND DIMENSIONS Continued COUNT INPUT WIRING SOURCE INPUT SIGNAL Left Switch Pin 6 DN 2 WIRE DC 3 WIRE DC IN2 12 VDC INT IN2 12 VDC INT IN2 12VDC AUX AUX AUX AUX PWR PWR PWR PWR COM Counter will read positive counts with terminal 6 not connected For negative counts connect terminal 6 to terminal 3 For Count Inhibit or Interval Mode Start wire terminal 6 in the same manner as terminal 5 ENCODER INPUT WIRING RESET INPUT WIRING SINK I