xr2400 users guide - Affordable Security and Protection

image

Contents

1. 4 Special Fire Command Center Tones 4 Fire Command Center User MENU i 5 Section Page Alarm Silence iialra ae aiaaiii 6 Sensor Reset nia la PARKERER NESE 6 Outputs ON Off 7 Zone Status iaia a 7 System otalUsifai nata iaia ea al 8 System esta dali ile 8 User Codes aodare ola 9 User Code Authority Levels n 9 Programming Custom User Codes 10 AmbushCodesic 4 te iii dae 11 Deleting User Codes i 11 Changing User COdes 11 Setting the Date and Time nrnna 12 Display Events licia iaia a 13 About the Display Events Seciton 14 Zone Event Displays ii 14 User Code Change Event Displays 14 Supervisory Event DisplayS iii 14 System Monitor Event Displays eeren 14 SErvice REQUESt t stiirionaiiniagilialicnferiaibnica 15 FireDrilliose scie 15 Emergency Evacuation Plans The National Fire Protection Association recommends that you establish an emergency evacuation plan to safeguard lives in the event ofa fire or other emergency Use the following steps as a guide Draw a floorplan of your home or business On aclean sheet of paper draw the walls windows doors and stairs Also draw any obstacles that a person may encounter while exiting the building such as large furniture or a
2. The user code you have entered is not recognized by the system Check the user code and try again INVALID LEVEL All user codes have authority levels that allow the user to only access certain functions When a user attempts a function outside their authority the INVALID LEVEL message displays SYSTEM TROUBLE or SERVICE REQUIRED There is a problem with one or more of the components in your system Contact our service department as soon as possible SYSTEM BUSY The Addressable Fire Alarm Control Panel is performing another task of a higher priority This usually only takes a few moments Special Fire Command Center Tones Your keyboard also contains a small speaker that allows it to alert you to events as they occur on your system Below are brief descriptions of the different tones you ll hear from the keyboard Fire Alarm tone An intermittent sweeping siren that sounds until the fire alarm is silenced Key press tone A short beep each time you press a key and it s acknowledged by the system Trouble tone A steady tone indicating a trouble condition on your system Press any key except TEST or DRILL to silence This only silences the keypad and does not correct the condition that originally caused the trouble Introduction Fire Command Center User Menu Many of the features of your system have been put into a User Menu that you can access from the Fire Command Center or the Remote Fire Command Center The menu requires
3. User Code Each user also has a 3 to 5 digit number they enter into the keyboard NOTE A User Code cannot begin or end with zero or be in the range of 980 to 989 or be in the range of 1 to 299 User Names Each code may also be programmed with the user s name Up to 16 characters may be entered User Level The user is also assigned a level of authority 1 to 9 or customized authority by the person administrating the system that determines the functions the user can access The following table lists system functions users are allowed to access based on the authority level assigned to their codes User Menu User Code Authority Levels Menu Options Sensor Reset Zone Status System Status Display Events Alarm Silence System Test Zone Monitor Outputs On Off Service Request Fire Drill Set Time User Codes Note Service Request is not displayed if it has not been enabled on your system 13 Programming Custom User Codes In addition to the preset authority levels you can also create custom authority levels by selecting the CUSTOM option at the time the user is being added to the system This option allows you to assign specific User Menu access to individual users Adding User Codes 1 Access the User Menu 2 Press COMMAND until USER CODES displays NOTE You must have a level 9 authority If you enter the User Menu with a lower authority the keyboar
4. loss or injury Introduction About Your Addressable Fire Alarm Control Panel The Addressable Fire Alarm Control Panel has been designed with your safety and comfort in mind It uses the latest in computer based technology to create the most advanced and user friendly fire security and access control system available The Addressable Fire Alarm Control Panel combines ease of use with a simple to understand Fire Command Center display to offer the full range of features requested by today s fire system owners You can turn portions of your protection on or off at any time by pressing a few keys You can add delete and change personal user codes at any time or check the status of protection devices in the system An added feature of the Addressable Fire Alarm Control Panel is the membrane keyboard that has four additional function keys you may use to easily perform a variety of functions For more information about these prompts please refer to LT 0185 XR200 XR2400F Programming Guide Fire Command Center The XR2400F comes with a built in LCD display with a 20 key membrane keyboard called the Fire Command Center The keyboard is mounted behind an opening in the door of the red enclosure The keyboard can be used to perform a variety of functions as listed in this User s Guide Introduction A Remote Fire Command Center is also available to use with the XR2400F Addressable Fire Alarm Control Panel The remote keyboard can b
5. the ZONE NO prompt enter the zone number you want to check and press COMMAND The zone number and name is displayed followed by its status For example a zone status for zone one 1 might be OFFICE SMOKE OKAY The displays ol are OKAY the zone is in anormal condition BYPAS the zone is bypassed BAD the zone is in a bad condition 7 After displaying the zone status ZONE returns for you to enter another zone number 11 System Status User Code Level All users Function Displays the current condition of internal system hardware System Status displays the condition of the panel s AC power battery power and optional panel tamper When System Status is selected each monitor is displayed followed by OKAY or TRBL Trouble to indicate the current condition Checking the System Status 1 Access the User Menu 2 Press COMMAND until SYSTEM STATUS displays 3 Press any SELECT key The display starts listing each system monitor and status For example AC POWER OKAY Below are the System Monitor displays Display What it monitors AC POWER AC power BATTERY Battery power TAMPER Panel enclosure tamper These are followed by either OKAY or TRBL trouble If TRBL is displayed call the service department for assistance 4 The system then displays its firmware version for example VER_105_7 24 00 the panel model MODEL XR2400F then exits the User Menu 12 System Test User Code Leve
6. ECT keys There are four keys under the display called the SELECT keys They allow you to choose what to do by pressing the SELECT key under choices being shown in the display 6 Data Entry keys These keys allow you to enter your user code and other information into the system The ARROW key The ARROW key is used to go back through the displays while operating your system You can press the ARROW key to back up through the list of functions in the User Menu or to make a correction by erasing the last character you entered The COMMAND key The COMMAND key allows you to advance through the displays or User Menu or complete a data entry function Status LEDs The Fire Command Center incorporates three LEDs to indicate the status of the system The three indicator lights are described below POWER LED This LED remains ON steady when both AC and battery input are good The LED turns OFF when AC input is low The LED flashes for 1 2 second intervals when battery input is low TROUBLE LED This LED turns ON when any trouble is displayed in the status list such as AC battery phone line transmit ground fault NAC or any zone trouble This light is OFF when no trouble is displayed in the status list ALARM LED The ALARM LED is ON when any alarm is currently displayed in the status list This LED is OFF when no alarm is currently displayed in the status list Introduction User Options Menu Press and hold the ARR
7. J__ Jj User 5 Guido J JL NiZ400F Silencing an Alarm While the fire alarm horns strobes or sirens are sounding use one of the following methods to silence the alarm 1 Turn the keyswitch to enable the four function keys Then press the SILENCE key 2 Enter your user code Then press COMMAND Note You may silence an alarm using both of the above methods on the Remote Fire Command Center as well Copyright 2000 Digital Monitoring Products Inc Information furnished by DMP is believed to be accurate and reliable This information is subject to change without notice User s Guide for XR2400F Addressable Fire Alarm Control Panels Table of Contents Section Page Emergency Evacuation Plans iv About Your Addressable Fire Alarm Control Panel 1 Fire Command Center tennene nnn rennene 1 USEF Men criari Lp 1 The Select KEYS 2 The Fire Command Center nenna 2 Data Entry KEYS 2 The Arrow key 2 The Command key i 2 Status LEDS civ utah iaia ea 2 Power LEDi Vai alla techie deen 2 Trouble LED iii irreali Per ereere a rere 2 Alarm WED scala aa i 2 User Options MENU i 3 Four Function Keys iiaa EN 3 SIEENGE KEV iriipr air ra 3 RESET KEY aaa 3 TEST Keystone alan ina 3 DRILL Kevin iaia i 3 Remote Fire Command Center n 3 Special Fire Command Center Displays
8. OW and COMMAND keys for about two seconds The display shows SET BRIGHTNESS Use the left SELECT key to lower the display brightness Use the right SELECT key to increase the display brightness Press COMMAND At SET TONE use the left SELECT key to lower the keyboard tone Use the right SELECT key to raise the tone Press COMMAND At SET VOLUME LEVEL use the left SELECT key to lower the keyboard volume Use the right SELECT key to raise the volume Press COMMAND AtMODEL NUMBER the model number of the keyboard is displayed Press the ARROW key to exit out of the User Options menu Four Function Keys The Fire Command Center has been designed with four additional keys on the left side of the keypad After turning the keyswitch you can quickly perform vital functions using these four keys SILENCE Key Pressing the SILENCE key will silence the alarm bells RESET Key Pressing the RESET key will perform a sensor reset and silence the alarm bells TEST Key Pressing the TEST key will perform a system test DRILL Key Pressing the DRILL key will display a prompt SURE YES NO Press YES to begin the fire drill Press NO to return to the status list Introduction Remote Fire Command Center The XR2400F Addressable Fire Alarm Control Panel canbe expanded by adding a Remote Fire Command Center With the Remote Fire Command Center user s can access the User Menu and perform the same functions as the Fire Command Center in the p
9. TEMP CODE temporary code NO SYS STAT system status NO SERV REQ service request NO SYS TEST system test NO FIRE DRIL fire drill NO YES allows you to then enter the number of days 1 to 250 that a temporary user code can operate Default is 7 days Temp users are deleted from the system at 12 00 AM on the last day 11 Press the ARROW key to exit the User Menu Note It is recommended that user codes be enabled for only the function shown above Other burglary functions are available to add to a user code but are not relevant and therefore are not recommended User Menu Ambush Codes Your system may be programmed to allow user number one 1 to be an Ambush code This Ambush code functions identically to a standard code with the exception that it sends a silent alarm to the central station This silent alarm alerts the operator to a duress situation at the premises and prompts the immediate notification of authorities Deleting User Codes 1 2 3 4 Atthe USER NUMBER The display then changes back to USER NUMBER Access the User Menu Press COMMAND until USER CODES displays Press any SELECT key ADD DEL CHG is displayed Press the SELECT key under DEL to delete a user code from the system You must have a user code level of 9 or have a custom user code with that authority to be able to delete a user code prompt enter the user number you want to delete and press COMMAND The displays chan
10. and changing user codes Supervisory Problems with the system s hardware components The system s memory can hold amaximum of 200 events for 45 days Any event older than 45 days is cleared automatically by the system Also once the full 200 events are stored any new event causes the oldest event to be cleared Using the Display Events 1 2 3 Access the User Menu Press the COMMAND key until DISPLAY EVENTS displays Press any SELECT key The display shows FRST LST PRT SRT Select FRST first to view the oldest to newest events Select LST last to view the newest to oldest events If you select FIRST use the COMMAND key to scroll up through the events If you select LAST use the ARROW key to scroll down through the events Select SRT sort to sort through the Display Events log and collect information specific to a user or system event Select PRT print to print the complete Display Events log User Menu To use the Sort feature press the SELECT key under SRT FRST DATE 8 21 is displayed Press any SELECT key and enter a 4 digit beginning date for the sort Press COMMAND LAST DATE 10 17 is displayed Press any SELECT key and enter a 4 digit ending date for the sort Press COMMAND USER NUMBER is displayed To sort events for a particular user enter the user number or press COMMAND to sort for all users To search for a user press any SELECT key then use the COMMAND and ARROW keys to
11. anel All of the keys except the four function keys can be used at any time without turning the keyswitch The four function keys can only be used when the keyswitch has been turned to the enable position These keys are the same as those on the Fire Command Center in the panel Both keyboards also have the same displays and prompts Follow the same instructions for using both keyboards Below is an illustration of the Remote Fire Command Center showing the keyswitch lock that enables the four function keys LCD Display Status LEDs SELECT keys COMMAND Key ARROW Key Function Keys Data Entry Keys Special Fire Command Center Displays As you use your system you will occasionally see a display that asks you to enter a code or that describes a condition on the system Below are some examples of the displays you will see ALARM A 24 hour zone such as a fire zone has been tripped Your system may sound bells and or sirens TROUBLE There is a problem with a protection device or system component This display is accompanied by a description of the problem ENTER CODE The system requires you to enter your user code User codes can be required for turning your system on turning your system off and many other functions As you enter your user code the display shows an asterisk in place of each digit pressed This keeps others from seeing your user code on the display as it s entered TRY AGAIN or INVALID CODE
12. browse through the user names in the system When the user you want is displayed press any SELECT key then press COMMAND Next the display shows five event types that you can include in the sort Press the rightSELECT key to display YES as the event type name is displayed Press COMMAND The following are the five sort event types ACCESSES door accesses granted Not Applicable DOOR NUMBER leave blank for all doors Not Applicable ZONE EVENTS zone alarms troubles and restorals USER EVENTS adding deleting and changing user codes SUPERVISORY system hardware problems After the last event type is displayed again the display shows FRST LST PRT SRT Atthis point you can view or print the new sorted Display Events or press SRT for a new sort 17 About the Display Events Section This section of the user s guide shows the User s Guide Display Events items for the Fire Command Center and Remote Fire Command Center displays While in the Display Events function use the COMMAND and ARROW keys to go forward or backward through the list of events Zone Event Displays This section displays alarms troubles and other events that could occur on your protection zones Some of the Zone and Event types listed here are not applicable to the XR2400F Please disregard any displays that are not discussed in this User s Guide Display Description An alarm occurred at 10 23 pm on Oct 17 Press any SELECT key to
13. change the Day Date or Time that is currently in the system DISPLAY EVENTS Allows you to view or print the last 200 events that occurred on your system SERVICE REQUEST Allows you to send a message to the central station requesting service on the alarm system FIRE DRILL Allows you to test the system s notification appliances such as fire bells The following pages detail each user menu item and provide instructions on when and how to use them properly User Menu Alarm Silence User Code Level 2 and above Function Silences the alarm bell or siren during an alarm Alarm Silence allows you to turn off the alarm bell or siren connected to your system during an alarm Using Alarm Silence does NOT stop an alarm report from being sent to the central station and does not reset any alarmed devices Use the Sensor Reset function to reset devices such as smoke detectors that have latched in alarm Note You can also silence an alarm by entering your user code and pressing COMMAND while the bell or siren is still sounding Silencing the Alarms 1 Access the User Menu 2 ALARM SILENCE displays 3 Press any SELECT key The system silences the bell or siren and exits the User Menu Using the SILENCE function key The SILENCE function key can only be used after the keyswitch has been turned to the Enable position The SILENCE key silences the alarms The SILENCE key does NOT stop the alarm report from being se
14. d will not display USER CODES 3 Press any SELECT key ADD DEL CHG displays 4 Press the SELECT key under ADD to add a new user code 5 Atthe USER NUMBER prompt enter a user number and press COMMAND The display changes to CODE NO 6 Enter a user code of 3 to 5 digits and press COMMAND The user enters this number each time they make changes If using access cards present the card instead of entering a code The code is displayed for four seconds After the code is entered the display changes to USER NUMBER 7 A16 character name may be entered to identify the user Press any top row key to clear the current name You may then enter the new name After the name is entered press COMMAND 14 8 The display changes to LEVEL CUSTOM Select LEVEL to assign a standard set of authorized functions as outlined in the User Code Authority Levels table on the previous page 9 Atthe LEVEL display enter an authority level from 1 to 9 Press COMMAND The displays shows USER ADDED 10 Select CUSTOM to customize the functions you want the user to access This allows users to have certain capabilities outside of a standard authority level The following chart shows the custom menu with default selections ALM SLNC alarm silence NO USR CODE user code NO SNSR RST sensor reset NO TIME day date and time NO OUTPUTS outputs on off NO DIS EVNT display events NO ZN STATS zone status NO
15. e placed anywhere throughout the premises Both keyboards have four additional function keys which can be used for silencing the alarms resetting the smoke detectors testing the system and performing fire drills Both keyboards require the user to turn a keyswitch to enable the four function keys User Menu The keyboards also give you access to the User Menu which contains all of the functions necessary to fully operate your system Note Because the XR2400F is based upon the XR200 Command Processor some prompts provided on the User Menu are not necessary for XR2400F operation If the User Menu provides you with an option not discussed in this User Guide please disregard it and move on to the next prompt by pressing the COMMAND key The following menu items are not used with the XR2400F e Door Access e Armed Areas e Bypass Zones e Zone Monitor e Schedules The Fire Command Center Your system comes equipped with a built in easy to use Fire Command Center that allows you to properly operate the system The keyswitch to the left of the keyboard must be turned to the enable position before you can use the four functions keys It is not necessary to use the keyswitch when using a user code to perform operations The illustration and descriptions below highlight some features of the Fire Command Center LCD Display Status LEDs SELECT keys Keyswitch Function Data Entry Keys COMMAND Key Keys ARROW Key The SEL
16. es There are 2 event types TBL Trouble RST Restore System Monitor Event Names There are 5 system monitors POWER AC power to panel BATTERY On panel LINE 1 Phone line number 1 LINE 2 Phone line number 2 TAMPER On panel box Service Request User Code Level 8 and above Function Allows you to send a Request for Service message to the central station when there is a problem on your system After the Display Events function and if this feature is programmed for your user code you will see SERVICE REQUEST displayed in the User Menu If you would like to send a Request for Service report to the central station press any top row SELECT key while SERVICE REQUEST is displayed After the Request for Service report is sent REQUEST MADE is displayed for four seconds Note This function is only displayed if itis enabled on your system and the user code has authority User Menu Fire Drill User Code Level 8 and above Your system may be programmed to allow a Fire Drill The Fire Drill is used to test the fire bells horns and other notification appliances in your system The Fire Drill turns on your system bell circuit but does not send a message to the central station Starting a Fire Drill 1 Access the User Menu 2 Press COMMAND until the FIRE DRILL displays Press any SELECT key 3 SURE YES NO is displayed 4 Press the SELECT key under YES to start the Fire Drill test Ending a Fire Drill 1 En
17. ges to USER DELETED allowing you to delete another user Press the ARROW key twice to exit the User Menu User Menu Changing User Codes 1 2 Press the COMMAND key until USER CODES displays 3 Press any SELECT key ADD DEL CHG is displayed 4 5 At the USER NUMBER Access the User Menu Press the SELECT key under CHG to change a user code prompt enter the user number to change and press COMMAND The display changes to CODE NO Press a SELECT key and enter the new user code Press COMMAND Note Changing a user code does not change the user number di The display then shows the current user name Press any top row key to clear To enter a Custom Name press the number key above the letter that you wish to enter Each number key displays three letters Press the top row select key under the letter you wish to enter Repeat until entire name is entered The display changes to LEVEL CUSTOM Refer to Adding User Codes on the previous page for a description of this prompt After entering the authority level the displays shows USER CHANGED for five seconds followed by USER NUMBER This display allows you to enter another user number to change Press the ARROW key twice to exit the User Menu 15 Setting the Date and Time User Code Level 8 and above Function Allows you to change the current date and time displayed on the Addressable Fire Alarm Control Panel and used by the sy
18. l 4 and above Function System Test is used to test the battery alarm bell or siren and communication to the central station The System Test function begins automatically as soon as you select it Using the System Test Function 1 Access the User Menu 2 Press COMMAND until SYSTEM TEST displays 3 Press any SELECT key The system test begins automatically and the display shows 1 BELL SOUNDING during a two second bell test then 2 BATTERY OKAY or BATTERY TRBL to indicate the condition of the battery then 3 TRANSMIT TEST and ATTEMPT NO 1 during the transmit test then 4 TRANSMIT OKAY or TRANSMIT FAILED to show the results of the transmit test then 5 TEST END to indicate the System Test is complete 6 Youcanendthe transmit test by pressing the ARROW key The transmit test does not operate on local systems Using the TEST function key The TEST function key can only be used after the keyswitch has been turned to the Enable position User Menu User Codes User Code Level 9 only Function Allows you to add delete and change a user s person operating the system user code or authority level There are three characteristics associated with each user code that define its capabilities within the system 125 34812 7 User Code User Number User Level User Number Every user is numbered This number identifies them to the system and can be transmitted to the central station
19. nt to the central station 10 Sensor Reset User Code Level All users Function Resets smoke or other latching detectors Also clears Fire Supervisory alarm and trouble displays Sensor Reset is used to reset smoke and other latching detectors after they have been tripped Once these detectors have tripped they must be reset before they can detect any additional alarm conditions When Sensor Reset is selected power to the detectors is temporarily removed by the system allowing them to reset Make sure all smoke is cleared from around the area of the smoke detectors before performing a Sensor Reset to prevent the alarm from occurring again Resetting the Sensors 1 Access the User Menu 2 Press COMMAND until SENSOR RESET displays 3 The display shows SENSORS OFF for five seconds followed by SENSORS ON 4 The display automatically exits the User Menu Using the RESET function key The RESET function key can be used after the keyswitch has been turned to the Enable position The RESET key performs a sensor reset and silences the alarm bells User Menu Outputs On Off User Code Level 5 and above Function Allows you to turn the system relay outputs on and off This function is used to individually turn your system s relay outputs on and off Your system may use these outputs to control such devices as smoke detectors heat detectors and other notification appliances Turning the Outputs On and Off Acce
20. ppliances Develop escape routes Determine at least two routes the occupants in each room can take to safely escape One route can be the most obvious such as the door Another can be through a window that can be easily opened If the window is high off the ground an escape ladder should be provided Draw arrows on the floorplan to show escape routes from each room Decide where to meet Prearrange a meeting place outside and away from where emergency personnel are likely to be working A neighbor s house or across the street in the front of the house are good locations Always perform a head count to make sure all occupants safely exited NEVER ENTER A BURNING BUILDING If the head count shows one or more persons missing give this information immediately to the authorities Never enter a building to look for someone Practice your escape plans Devising an escape plan is only the beginning before the plan can be effective everyone should practice the escape routes from each room 4 First Floor Second Floor IA Fire Escape Window Ladder Building Front Building Back 7 L y Early detection The best way to survive a fire or other emergency is to get out early The installation of a fire alarm system with smoke and carbon monoxide detectors in each room can greatly decrease your risk of
21. see the zone number and zone type ALR 10 23P 10 17 OFFICE SMOKE Zone Type There are 7 possible zone types you may see here PANC Panic SUPV Supervisory AUX2 Auxiliary 2 FIRE Fire EMRG Emergency AUX1 Auxiliary 1 BURG Burglary Event Types There are 7 event types you may see here ALR Alarm TBL Trouble RST Restore LOW Low battery FLT Zone Fault MIS Missing wireless transmitter SVC Service smoke detector 18 User Code Change Event Displays This displays any addition deletion or change to a user code Display ADD 11 41A 10 17 US 19 BY US 12 User Code Event Types There are 3 event types you may see here ADD User added DEL User deleted CHG User code or authority level has been changed Supervisory Event Displays This displays the date and time of an automatic test report Description User 19 added by user 12 at 11 41 am Press the Select key under either user US number for the user name Display MSG 11 58P 10 17 AUTO RECALL System Monitor Event Displays This displays any problems with the system s AC power battery or phone line s or any opening of a tampered panel box Description The test report was sent to the central station at the date and time shown Display Description TBL 11 41A 10 17 An AC failure occurred on Oct 17 Press POWER the SELECT key under 10 17 for the time the failure occurred User Menu System Monitor Event Typ
22. ss the User Menu Press COMMAND until OUTPUTS ON OFF displays Press any SELECT key to display OUTPUT ON OFF Enter the output number you want to turn on or off The output number will appear in the display Pre e 5 With the output number displayed press the SELECT key under ON or OFF The output is then turned on or off depending on your selection and remains in that state until you change it Under certain conditions some outputs cannot be turned on If you select a restricted output the display shows CANNOT TURN ON 6 The system automatically removes the output number and a new output number can be entered Refer back to step 4 Press the ARROW key to exit the User Menu User Menu Zone Status User Code Level All users Function Displays a list of bypassed or alarmed zones Also allows you to check the status of individual zones Zone Status can be used to give you a list of zones by category or display the current status of an individual zone number The three categories that apply to the XR2400F are Alarmed Bypassed and Number Checking the Zone Status Access the User Menu Press COMMAND until ZONE STATUS is displayed Press any SELECT key to display ARM BYPS ALR NBR Select BYPS for a list of zones that are currently bypassed A A OD Select ALR for a list of zones that have gone into alarm during the current or previous armed period Press NBR and ZONE NO will be displayed 6 At
23. stem to log events in its Event Memory program Setting the System s Date and Time 1 Access the User Menu 2 Press COMMAND until TIME displays Press any SELECT key 3 Thedisplayshowsthe current day and time Press the COMMAND key The current date is displayed Press the COMMAND key to make any changes 4 TIME DAY DATE is displayed 5 Press the SELECT key under TIME to change the time The displays shows AM PM Enter the current time and select AM or PM The display changes back to TIME DAY DATE 6 Press the SELECT key under DAY to change the day of week SUN MON TUE WED is displayed If the current day of the week is not displayed press the COMMAND key 16 7 THU FRI SAT is displayed Press the SELECT key under the correct day You can use the ARROW key to toggle between the two day of the week displays Press the SELECT key under DATE to change the date The displays shows MONTH Enter one or two digits for the month Press COMMAND DAY Enter up to two digits for the day Press COMMAND YEAR Enter up to two digits for the year Press COMMAND The display returns to the TIME DAY DATE display Press the ARROW key to exit the User Menu User Menu Display Events User Code Level All Users Function Allows you to review up to 200 past system events There are three applicable event types Zone Activity Zone alarms troubles and restorals User Code Changes Adding deleting
24. ter your code and press COMMAND to end the Fire Drill 2 The Fire Drilltestwill automatically end with an ALARM SILENCE or the programmed Bell Cutoff time Using the DRILL function key The DRILL function key can be used after the keyswitch has been turned to the Enable position Press the DRILL function key The display will show SURE YES NO Press YES to begin the fire drill The fire drill will automatically end after the programmed Bell Cutoff time 19 LT 0560 8 00
25. you to enter your user code and then only shows those functions to which you have access Some features displayed on the User Menu are not necessary for the XR2400F Addressable Fire Alarm Control Panel Please disregard these prompts and displays You may skip any displays and prompts not discussed in this User Guide by pressing the COMMAND key To access the User Menu 1 Press the COMMAND key until MENU NO YES displays 2 Select YES The display shows ENTER CODE Enter your user code and press COMMAND You can now scroll down through the list of system features available to your authority level User Menu Options The list below shows the User Menu options in the order they will appear in the display A description of the options follows in this guide Menu Option Description ALARM SILENCE SENSOR RESET Silences an alarm bell or siren Resets smoke detectors that have latched due to an alarm condition Introduction OUTPUTS ON OFF Allows you to turn on or off any of the outputs ZONE STATUS Allows you to enter a zone number and see if that zone is either armed bypassed in alarm open or shorted SYSTEM STATUS Displays the current condition of the system s AC power backup battery and panel tamper optional SYSTEM TEST Tests the system s siren communication tothe central station and backup battery USER CODES Allows you to add delete or change user codes and authority levels TIME Allows you to