SG Sensaphone Option Addendum

image

Contents

1. Cell type batteries Refer to the Sensaphone users manual for details CHAPTER 1 SG Sensaphone Option Overview This User s Guide Addendum is provided as preliminary installation and interfacing instructions for your SG Series UPS incorporating a Sensaphone 1104 Remote Telephone Management System This manual is to be used in conjunction with the SG Series User s Manual Sensaphone User s Manual and the Sensaphone X10 Manual Read this handbook carefully in the order it is presented prior to installing and operating your units This will save you time and effort in your installation and applica tion The illustrations will also familiarize you with the equipment operating and pro gramming modes as well as indications Always operate this equipment within the guidelines and specifications SENSAPHONE 1104 SG1K 2T UPS SG1KRM 2T UPS CHAPTER 2 Installation Inspecting the Equipment If any FALCON equipment has been damaged during shipment keep the shipping cartons and packing materials for the carrier and file a claim for shipping damage If you discover damage after acceptance file a claim for concealed damage To file a claim for shipping damage or concealed damage 1 File with the carrier within 15 days of receipt of the equipment 2 Send a copy of the damage claim within 15 days to the Falcon Service Department UPS amp Sensaphone 1104 Setup 1 Verify that the following is included in the UPS shippin
2. OWNER S GUIDE ADDENDUM UNINTERRUPTIBLE POWER SYSTEM FOR MODELS SG1K 2T amp SGIKRM 2T SENSAPHONE 1104 FALCON ELECTRIC 5116 Azusa Canyon Road Irwindale CA 91706 Tel 626 962 7770 Fax 626 962 7720 PRLLON WWW FALCONUPS COM 800 842 6940 The information contained herein is the property of FALCON ELECTRIC is proprietary confidential and not to be disclosed disseminated or used except for the purpose provided by FALCON Electric Inc OM48204 7 03 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions which must be followed during the installation operation and maintenance of this device and it s batteries Please read all instructions before operating this equipment and save this manual for future reference CAUTION All of the models presented herein are designed for installation and use in a controlled environment free of contamination CAUTION This device utilizes voltage that may be hazardous Do not attempt to disassemble This unit contains no user replaceable parts Refer all servicing to Falcon Electric Inc CAUTION This device is not intended to be used in conjunction with life support or operating room equipment CAUTION Always unplug this device prior to cleaning and never apply liquid or spray deter gent on the UPS CAUTION When replacing the UPS batteries use the same number and type of batteries 6 pieces of D
3. STATUS followed by the 6 button on the Sensaphone The UPS outlets should turn on TO TURN OFF THE UPS OUTLETS 1 amp 2 Depress the STATUS followed by the 3 button on the Sensaphone The UPS outlets should turn off You can also dial into the Sensaphone and verify the outlet control Refer to the Sensaphone X10 and user s manual for detailed instructions INTERFACE CABLE SENSAPHONE INTERFACE CABLE 12 Conductor Cable CA080338 Type CMR or CL2R g stranded CN1 Rear View GND2 DB 9M Shrink Tube pasa in separate 2 Uty Loss B IE ka 3 Low Batt Orange GND4 ellov y 4 Bypass Alm do awy a a Use DB 9 Back Shell PE655365 5 Output SD amp Shrink Tube ae 2 places mouser 152 1309 in separate PE56501 cable Violet Red 6 Ring Lug 6 places PE57507 Note Cut off all unused conductors in cable CHAPTER 4 Technical Support Your FALCON Electric SG Series UPS is backed by one of the finest customer service teams assembled Write Call Fax or Email should you require technical assistance or service For Sensaphone 1104 technical support or repair issues please contact the manufacturer directly Technical support contact information is referenced in the Sensaphone User s Manual FALCON ELECTRIC INC 5116 Azusa Canyon Road Irwindale CA 91706 Voice 626 962 7770 Fax 626 962 7720 Service 800 842 6940 Email service falconups com WWW FALCONUPS COM Should service be de
4. g carton UPS Input line cord RS 232 software Owner s Guide Verify that the UPS unit is configured for the proper input output voltage This information is stated on the nameplate label located on the rear panel of the unit Verify that the following is included in the Sensaphone shipping carton Sensaphone 1104 with connected UPS interface cable Power Supply IEC320 to NEMA 5 15R adapter cable User s Manual and X10 Manual Install the six D cell batteries into the Sensaphone unit Refer to the Sensaphone users manual for details Select a suitable location for the UPS and Sensaphone unit near enough to the computer or equipment to be protected and monitored to allow connection of the equipment power plug s to the receptacles located on the rear panel of the UPS DO NOT BLOCK UPS AIR VENTS THE UPS MUST NOT BE INSTALLED IN AN ENCLOSED AREA Refer to the SG UPS Rear Panel Detail on the next page for the following steps a Connect the Sensaphone input power to UPS outlet 4 using the supplied IEC320 to NEMA 5 15P adapter cable b Connect the DB 9 MALE connector on the Sensaphone interface cable to the Sensaphone A Port on the UPS rear panel C Connect the DB 9 FEMALE connector on the Sensaphone interface cable to the Sensaphone B Port on the UPS rear panel SG1K 2T UPS REAR PANEL DETAILS SG UPS DIP SWITCHES Please refer to the SG Owner s Manual for details SENSAPHONE PORT A Connect Sensaphone inte
5. n gray wire 5 UPS Output Control Signal violet wire Turns UPS outlets 1 amp 2 on amp off Note UPS outlets 1 amp 2 are controllable by the Sensaphone and backed up by the UPS UPS outlet 3 is on continuously and backed up by the UPS UPS outlet 4 is on continuously and backed up by the UPS CONNECT SENSAPHONE INPUT POWER PLUG TO THIS OUTLET Loss of Sensaphone Input Power Alert Condition UPS lost it s output UPS amp SENSAPHONE ALERTS ALERT 1 Room temperature sensor located on the Sensaphone rear panel ALERT 2 Loss of utility voltage sensed at the UPS input UPS in battery mode ALERT 3 UPS at low battery approximately one minute of backup remaining ALERT 4 UPS is in bypass as a normal part of the UPS startup Ignore and reset the alarm OR UPS has been manually placed in bypass using the front panel button UPS is in an alarm condition Refer to the SG user s manual for alarm details SENSAPHONE POWER ALERT The Sensaphone has lost input power The UPS has lost its output due to a A sustained power outage and UPS shutdown b The UPS was manually turned off c The UPS failed and lost output UPS OUTLET CONTROL outlets 1 amp 2 only Follow the instructions in the Sensaphone X10 manual for details concerning the remote and local control of this function Should you want to test this output control function while the UPS is operating do the following TO TURN ON THE UPS OUTLETS 1 amp 2 Depress the
6. rface cable DB 9 male here SENSAPHONE PORT B Connect Sensaphone interface cable DB 9 female here SG UPS RS 232 PORT DO NOT CONNECT SENSAPHONE CONNECTORS HERE IEC OUTLET 1 amp 2 Switched by the Sensaphone and backed up by the UPS SG UPS COOLING FAN DO NOT BLOCK AIR FLOW IEC OUTLET 3 Not switchable and backed up by the UPS SG UPS LINE CORD INLET Connect the supplied line cord IEC320 end into the inlet IEC OUTLET 4 CONNECT SENSAPHONE INPUT LINE CORD HERE USING THE IEC320 to NEMA 5 15 ADAPTOR CABLE SG UPS INPUT FUSE Replace with same type and rating fuse SG1KRM 2T UPS REAR PANEL DETAILS SG UPS DIP SWITCHES refer to manual IEC OUTLET 4 Connect Sensaphone line cord here using thr IEC320 to NEMA 5 15 adaptor cable SENSAPHONE PORT A Connect Sensaphone DB 9 here SG UPS RS 232 PORT DO NOT CONNECT SENSAPHONE HERE SGUPS LINE e CORD INLET OPTIONAL EXTERNAL BATTERY CONNECTOR SG COOLING FAN DO NOT BLOCK AIR FLOW SENSAPHONE PORT B Connect Sensaphone interface cable DB 9 female here IEC OUTLET 3 Not switchable and backed up by the UPS IEC OUTLET 1 amp 2 Switched by Sensaphone and backed up by the UPS Connect the UPS input power cord to the UPS inlet located on the UPS rear panel Verify the UPS output voltage Dip Switch setting match your local utility
7. sired you must first obtain a Return Material Authorization number RMA and return shipping instructions from our customer service department Please have your UPS model serial numbers and date of purchase on hand prior to the call This information is located on the identification label on the rear panel of the unit This information is essential in retrieving your unit s historical records The RMA number issued must appear on the outside of the shipping carton The original shipping container must be used when returning any SG Series product Falcon Electric will not assume any responsibility for shipping damage In the event of shipping damage you will be charged for repairs due to the damage All units must be returned prepaid The address and shipping instructions will be given to you at the time the RMA is issued T Requesting Technical Information or Support You may request technical information or support by Email or telephone Please send your technical or support questions by Email to SUPPORT FALCONUPS COM You may contact a FALCON support engineer directly by calling the FALCON support line between 9 00 am and 4 00 pm PST 626 962 7770 8 FALCON Web Support Product data sheets specification and owner s guides are available in Adobe PDF format on our corporate website WWW FALCONUPS COM
8. voltage Refer to the SG Owner s Manual for details Connect the UPS input plug to a nearby grounded receptacle NEVER USE AN EXTENSION CORD Connect the input power plugs for the equipment you want to switch on and off to the UPS outlets 1 amp 2 only These outlets are battery backed up Connect the input power plugs for the equipment you want on all of the time to the non switched UPS outlet 3 This outlet is battery backed up UPS OUTLET 4 BOTTOM OUTLET for SG1K 2T OUTLET TO THE RIGHT FOR SG1KRMN 2T IS RESERVED FOR CONNECTING THE SENSAPHONE INPUT PLUG THE SENSAPHONE INPUT PLUG MUST BE CONNECTED TO THIS OUTLET READ THE SENSAPHONE OWNER S AND X10 MANUALS BEFORE GOING ANY FURTHER CHAPTER 3 Preliminary Operating Instruction SENSAPHONE CABLE CONNECTIONS amp ASSOCIATED ALERT CONDITIONS TEMPERATURE SENSOR Not 5 GND5 Used ROL LR A BONE GND1 1 GND2 2 GND 3 GND4 4 UPS amp INTERFACE CABLE CONNECTIONS GND1 Temperature Sensor Return 1 Temperature Sensor Signal GND2 Utility Loss Return orange wire 2 Utility Loss Signal brown wire GND3 On Battery Return blue wire Temperature Alert Condition 1 Alert Condition 2 Utility Loss to UPS 3 On Battery Signal white wire Alert Condition 3 UPS on at low battery GND4 Alarm On bypass Return green wire gt S A 4 Alarm On bypass Signal yellow wire Alert Condition 4 UPS in alarm or bypass GNDS UPS Output Control Retur