1.    Tail flick meter  18    Harvard  Apparatus    Panlab  H       14  IROUBLESHOOTING    This table features instructions to solve the most frequent problems     PROBLEM SOLUTION    een dossinobela tun e Check the condition of the fuses     The equipment does not send data  to the program Sedacom     By pressing START STOP button  or pedal lamp is not lit     When the animal removes the tail  the lamp does not turn off     FOCUS selector cannot select  values below 10     Can   calibrate the lamp     Tail flick meter    Check that the cable is connected  between the RS 232 device and the PC  serial port  see Figure 9     Make sure that both the serial port as the  device selected in the Sedacom program  are correct    The equipment will only send data when  after the experiment starts  the lamp  turns off because the animal has  removed the tail  If the lamp turns off  because has reached the safety time  see  Chapter 13  will not send data    Check that the cable is connected to the  lamp  see Figure 9     If it starts counting the time  but the  lamp does not light  check the condition  of the lamp    If the two items are correct  it could be a  fault in the membrane button     Verify that the V shaped accessory is  properly seated in    Make sure the hole is clean in the V  shaped accessory  if it is clogged with dirt  will not allow the passage of light    Clean the phototransistor located in the  lamp  if it is dirt can prevent light to be  detected    There is not an err
2.   the unit is suitable for purpose  You must follow preventive maintenance instructions   In case equipment has to be serviced you can arrange this through your distributor   Prior to Inspection  Servicing  Repair or Return of Laboratory Equipment the unit must  be cleaned and decontaminated     Decontamination prior to equipment disposal   In use this product may have been in contact with bio hazardous  materials and might therefore carry infectious material  Before disposal  the unit and accessories should all be thoroughly decontaminated  according to your local environmental safety laws        Tail flick meter    Harvard  Apparatus    Panlab  H    3  UNPACKING AND EQUIPMENT INSTALATION       WARNING  Failure to follow the instructions in this section may  cause equipment faults or injury to the user     A  No special equipment is required for lifting but you should consult your local  regulations for safe handling and lifting of the equipment    B  Inspect the instrument for any signs of damage caused during transit  If any  damage is discovered  do not use the instrument and report the problem to  your supplier    C  Ensure all transport locks are removed before use  The original packing has  been especially designed to protect the instrument during transportation  It is  therefore recommended to keep the original carton with its foam parts and  accessories box for re use in case of future shipments  Warranty claims are  void if improper packing results in damage during 
3.  materiais dos seus velhos aparelhos  esta a fazer uma enorme   contribuic  o para a protecc  o do ambiente     P      Tail flick meter  23    
4.  ment    la directive europ  enne 2002 96 CE  et afin d atteindre un certain nombre  d objectifs en mati  re de protection de l environnement  les r  gles suivantes doivent   tre  appliqu  es    Elles concernent les d  chets d   quipement   lectriques et   lectroniques  Le pictogramme  picto   pr  sent sur le produit  son manuel d utilisation ou son emballage indique que le produit est soumis     cette r  glementation  Le consommateur doit retourner le produit usager aux points de collecte  pr  vus    cet effet     peut aussi le remettre    un revendeur En permettant enfin le recyclage des  produits  le consommateur contribuera    la protection de notre environnement  C est un acte    cologique     D    Hinweis zum Umweltschutz     Ab dem Zeitpunkt der Umsetzung der europ  ischen Richtlinie 2002 96 EU in nationales Recht  gilt folgendes    Elektrische und elektronische Ger  te d  rfen nicht mit dem Hausm  ll entsorgt werden  Der  Verbraucher ist gesetzlich verpflichtet  elektrische und elektronische Ger  te am Ende ihrer  Lebensdauer an den daf  r eingerichteten    ffentlichen Sammelstellen oder an die Verkaufstelle  zur  ckzugeben  Einzelheiten dazu regelt das jeweilige Landesrecht  Das Symbol auf dem  Produkt  der Gebrauchsanleitung oder der Verpackung weist auf diese Bestimmungen hin  Mit der  Wiederverwertung  der stofflichen Verwertung oder anderer Formen der Verwertung von Altger  ten  leisten Sie einen wichtigen Beitrag zum Schutz unserer Umwelt     p      O    Informa
5. 0    21    Harvard  Apparatus    Panlab           6  INTRODUCTION    The LE 7106 Light Beam Analgesy meter is designed to provide all the necessary  technical elements to measure the response of rats and mice to pain stimulation by  means of a radiant heat applied to their tails     AMLGESY METER 1g 7108       Figure 5  LE 7106 Light Beam Analgesy Meter     The analgesy meter has an adjustable intensity heat source  a photoelectric based  animal response detector and a response latency chronometer with 0 01 second  resolution     The analgesy meter is standard equipped with a maximum stimulus duration of 20  seconds  This prevents tissue damage due to excessively prolonged stimulation  This  time setting can be modified  see chapter 13      6 1  SUPPLIED ACCESSORIES    e LE 7106 Control Unit  1     e Experimenting Unit  1     e Interconnection cable between Units  1     e Power cord  1     e RS 232 wire  1     e V shaped accessory 1     e Foot switch  1     e Restrainer  1        As option customer is able to order a calibration certificate        This certificate is not supplied by default with the instrument  This certificate is not free of cost and  must be done in factory     Tail flick meter    Panlab H Ache y   7  EQUIPMENT DESCRIPTION    7 1  CONTROL UNIT FRONT PANEL    START STOP TIME FOCUS    ANALGE  Y   METER LE 7106    Tim  Sec        Figure 6  Control Unit Front Panel     e START STOP  The lamp is turned on by pressing this button  If it were  necessary to turn of
6. Focus 50  249000   Focus  50  1 5    2  d depending on the focus and time                DIMENSIONS  Width x Height x Depth  232mm 111mm 297mm  Weight  3 65kg   Tail flick meter    21       Panlab H Harvard    DECLARACI  N DE CONFORMIDAD    DECLARATION OF CONFORMITY  DECLARATION DE CONFORMIT         Nombre del fabricante  Panlab s l u    Manufacturer s name  www panlab com   Nom du fabricant  info panlab com   Direcci  n del fabricante  Energ  a  112   Manufacturer s address  08940 Cornell   de Llobregat  Adresse du fabricant  Barcelona SPAIN   Declara bajo su responsabilidad que el producto  LIGHT BEAM ANALGESYMETER    Declares under his responsibility that the product   D  clare sous sa responsabilit   que le produit     Marca   Brand   Marque  PANLAB  Modelo   Model   Modele  LE 7106  Cumple los requisitos esenciales establecidos por la Uni  n Europea en las directivas siguientes     Fulfils the essential requirements established by The European Union in the following directives   Remplit les exigences essentielles   tablies pour l Union Europ  enne selon les directives suivantes     2006 95 EC Directiva de baja tension   Low Voltage   Basse tension  2004 108 EC Directiva EMC   EMC Directive   Directive CEM  2012 19 EU La Directiva de Residuos de Aparatos El  ctricos y Electronicos  WEEE    The    Waste Electrical and Electronic Equipment Directive  WEEE    Les d  chets  d   quipements   lectriques et   lectroniques  WEEE    2011 65 EU Restriccion de ciertas Sustancias Pel
7. Hardware User s Manual    Tail flick meter    Tail flick test       References   LE7106  76 0293     Version   V29 10 2014X    Panlab H    Harvard  Apparatus    Panlab  5 1 0   C Energia  112   08940 Cornella de LI   Barcelona   Spain   www  panlab com    International Calls   34 934 750 697  Domestic Call  934 190 709    Fax   34 934 750 699  Info Qpanlab com    Limitation of Liability    PANLAB does not accept responsibility  under any circumstances  for any harm or  damage caused directly or indirectly by the incorrect interpretation of what is    expressed in the pages of this manual   Some symbols may have more than one interpretation by professionals    unaccustomed to their usage   PANLAB reserves the right to modify  in part or in total  the contents of this document    without notice     Harvard  Apparatus    Panlab H       1  SYMBOLS TABLE    Recognising the symbols used in the manual will help to understand their meaning     DESCRIPTION SYMBOL    Warning about operations that must not be done because they can  messenger      e ue Pee AN  exposed to a hazard    MT MEM A    touched   Feo REEL Y  operative life    Waste Electrical and Electronic Equipment Directive  WEEE  w       2  GOOD LABORATORY PRACTICE    Check all units periodically and after periods of storage to ensure they are still fit for  purpose  Investigate all failures which may indicate a need for service or repair     Good laboratory practice recommends that the unit be periodically serviced to ensure
8. ata will not be sent to  the computer     e POWER  Power inlet  main switch and fuse holder     Tail flick meter  10    Panlab H Ni    7 3  EXPERIMENTATION UNIT    PHOTOTRANSISTOR LAMP RESTRAINER       Figure 8  Experimentation Unit        PHOTOTRANSISTOR  A phototransistor detects light when the animal moves  its tail     e LAMP  Heat is produced by a halogen lamp  see technical specifications for  further details   The lamp holder turns around its vertical axis to withdraw the  lamp and facilitate placement of the animal  Never turn the lamp on if it is not  positioned over the phototransistor as it can produce high temperatures     e RESTRAINER  Animal is kept in a restrainer  There are 2 metal cylinders in  which to correctly position the restrainer on the platform        ACCESSORY  It is strongly advised to work with the accessory at all times  It is  a V  shaped metal unit that must be placed over the phototransistor  It  protects the phototransistor from ambient light and lamp light  It is very  important to place the orifice of this piece over the phototransistor  see marks  on the unit   If it is placed in an incorrect position the light will never be  detected and time will reach 20 00  The small orifice reduces the amount of  light that reaches the phototransistor and makes the system less sensitive to  light     Tail flick meter    11    Panlab H       8  EQUIPMENT CONNECTION    The following figure shows the equipment connection        Figure 9  Equipment connect
9. e power inlet    Tail flick meter    Panlab H            2 Open fuse holder by pulling the  flange     with a regular A  screwdriver        Figure 2  Open fuse holder door     3 Extract fuse holder using the  screwdriver           Figure 3  Extract fuse holder     4 Replace fuses if necessary  Insert fuses in the fuse holder in the correct position        CORRECT INCORRECT  Figure 4  Fuses position     5 Insert again fuse holder  both possible positions are correct because power supply  is universal     6 Ifthe fuses blow again unplug the equipment and contact technical service     For electrical safety  never open the equipment  The power supply  has dangerous voltages     WARNING    Tail flick meter    Panlab  H       5  TABLE OF CONTENTS    7 1     7 3     10     11     11 1     11 2     12     13     14     15     16     SYMBOLS TABLE    GOOD LABORATORY PRACTICE    UNPACKING AND EQUIPMENT INSTALATION    MAINTENANCE    TABLE OF CONTENTS    INTRODUCTION    SUPPLIED ACCESSORIES    EQUIPMENT DESCRIPTION  CONTROL UNIT FRONT PANEL  CONTROL UNIT REAR PANEL    EXPERIMENTATION UNIT    EQUIPMENT CONNECTION    CHANGING THE LAMP    WORKING WITH THE EQUIPMENT    RECOMMENDATIONS  CLEANING THE RESTRAINER    CLEANING THE EXPERIMENTATION UNIT AND V HAPPED ACCESORY    SING THE COMMUNICATIONS PROGRAM    CHANGING SAFETY TIME    TROUBLESHOOTING    PREVENTIVE MAINTENANCE    TECHNICAL SPECIFICATIONS    Tail flick meter    Harvard  Apparatus    10    11  12  13  14    16  16    16  17  18  19  2
10. eter will run until a tail flick is detected        Figure 13  The animal moves its tail     7  Return the lamp to its BACK POSITION     8  Take note of the response time  if you are not using SEDACOM to record the  experimental data  otherwise data are automatically sent to the computer   and  prepare a new animal  repeating the process as many times as necessary     Tail flick meter  14    Harvard  Apparatus    Panlab            lt  gt  Focus 99    ae   o ee        E o  VA AE IIA   N                AA          10    Temperature  2C          0 5 10 15  Time  Sec        Figure 14  Temperature versus time at different focus intensity     The above graph displays the evolution of temperature versus time with different  focus intensities     AN warnine  The temperature of the lamp can be up to 200  C    Tail flick meter  15    Harvard  Apparatus    Panlab  H       11  RECOMMENDATIONS    1  When working with mice  as they have very thin tails  it is advisable to use low  focus values as to prevent harm to their tails     2  When working with rats  as they have thick tails  it is possible that low focus  values will not be able to stimulate the animal  In that case it will be necessary  to increase the focus value     3  Periodically  it will be necessary to clean the experimentation unit and ensure  that the accessory  V shaped metal unit  is correctly positioned     4  Once the animal is placed in the restrainer  it will be necessary to wait for 2  minutes for it to calm down  T
11. f the lamp before the animal had moved its tail this button  can be pressed again  When the START button is pressed  time will increase  until the animal moves its tail  At that time the lamp is cut off and time stops     e TIME  A 4 digit display that counts time while the lamp is on  If time reaches  20 00 the system will automatically turn off the lamp and the error message  Cut  Cut off  will be shown on the display  this is a safety measure to prevent    harm to the animal      e FOCUS  Decimal selector of heat intensity  It can be set from 10 to 99     Tail flick meter      Harvar  Panlab  HA Harvard  7 2  CONTROL UNIT REAR PANEL    FOCUS FOOT SWITCH RS 232 POWER    LE 7106    Fotus Foot Bwitch Rs 232    v  C    Made in Spain by Pan  ab s l     C     Rated Voltage  90 260 V AC 47 63 Hz 30 W       Figure 7  Control Unit Rear Panel     e FOCUS  4 pin connector that sends power to the lamp and sends light  detection information from the phototransistor to the control unit     e FOOT SWITCH  System can be activated remotely using a foot switch  It has  the same function as the START STOP button on the front panel     e RS 232  Data are transmitted through this DB9 connector to the computer by  the serial port using the Sedacom software  not included  should be purchased  separately   Data are sent to the computer each time a correct test is  completed  lamp is turned off because the animal moves its tail   If a test is  finished by pressing STOP or time reaches 20 00 then d
12. h all computer  operation the following safety precautions are advised     WARNING    To reduce the chance of eye strain  set up the PC display with the correct  viewing position  free from glare and with appropriate brightness and  contrast settings       To reduce the chance of physical strain  set up the PC display  keyboard  and mouse with correct ergonomic positioning  according to your local  safety guidelines     Tail flick meter    Panlab H Ade    4  MAINTENANCE    WARNING  Failure to follow the instructions in this section may cause  equipment fault     e PRESS KEYS SOFTLY   Lightly pressing the keys is sufficient to activate them    e Equipments do not require being disinfected  but cleaned for removing urine   faeces and odour  To do so  we recommend using a wet cloth or paper with soap   which has no strong odour   NEVER USE ABRASIVE PRODUCTS OR  DISSOLVENTS     e NEVER pour water or liquids on the equipment     e Once you have finished using the equipment turn it off with the main switch  Clean  and check the equipment so that it is in optimal condition for its next use     e The user is only authorised to replace fuses with the specified type when necessary     OPENING FLANGE    SWITCH  FUSE HOLDER       Figure 1  Power inlet  main switch and fuse holder     FUSE REPLACEMENT    In case of an over voltage or other incident in the AC net making it impossible  to turn on the equipment  check fuses according to the following procedure     1 Remove power cord from th
13. his way  false measurements of movements  caused by animal stress will be avoided     11 1  CLEANING THE RESTRAINER    WARNING  In order to clean the restrainer never use neither alcohol nor  alcoholic derived products  otherwise stripes will appear in the transparent  plastic     To clean the restrainer you can use a slightly wet cloth and then dry it with a dry cloth   If it s too dirty you can wet the cloth with a soapy solution  then remove foam with a  wet cloth and finally dry it with a dry cloth     11 2  CLEANING THE EXPERIMENTATION UNIT AND V HAPPED  ACCESORY    To clean the surface of experimentation unit and the V shaped accessory you can use  a slightly wet cloth and then dry it with a dry cloth  If they re too dirty you can wet the  cloth with a soapy solution  then remove foam with a wet cloth and finally dry it with a  dry cloth     Tail flick meter  16    Harvard  Apparatus    Panlab  H    12  SINGTHE COMMUNICATIONS PROGRAM       The purchase of the Sedacom software is needed for transferring the data to a  computer  please contact your local sales delegate for more information   The  Sedacom software reference is composed by a USB Flash key containing the software  Installer  a License for use and the Sedacom User s Manual   Follow next instructions     e Please refer to the Sedacom User s Manual for the instructions about how to  install and use the software with the present device     e Aserial port  RS232  communication cable  provided with the present dev
14. ic waste Consumers are  obliged by law to return electrical and electronic devices at the end of their service lives to the  public collecting points set up for this purpose or point of sale  Details to this are defined by the  national law of the respective country  This symbol on the product  the instruction manual or the  package indicates that a product is subject to these regulations  By recycling  reusing the materials  or other forms of utilising old devices  you are making an important contribution to protecting our  environment     taf          Nota sobre la protecci  n medioambiental     Despu  s de la puesta en marcha de la directiva Europea 2002 96 EU en el sistema legislativo  nacional  Se aplicara lo siguiente    Los aparatos el  ctricos y electr  nicos  as   como pilas y bater  as  no se deben  tirar ala basura dom  stica  El usuario est   legalmente obligado a llevar los aparatos  el  ctricos y electr  nicos  as   como pilas y bater  as  al final de su vida   til a los puntos de  recogida municipales o devolverlos al lugar donde los adquiri    Los detalles quedaran definidos  por la ley de cada pa  s  El s  mbolo en el producto  en las instrucciones de uso o en el embalaje  hace referencia a ello  Gracias al reciclaje  a la reutilizaci  n de materiales i a otras formas de reciclaje  de a usados  usted contribuir   de forma importante a la protecci  n de nuestro medio  ambiente     P            Remarques concernant la protection de l environnement      Conform 
15. ice   is needed for the connection of the present devices to the computer in which  the Sedacom software is installed  Please refer to the present User s Manual  for the instruction about how to connect this cable to the device     e Ifthe computer doesn t have any serial port  the RS232 USB adapter is needed   ref  CONRS232USB  contact your local sales delegate for more information     WARNING  the RS232 communication cable provided with the device is used for any  connection of the device with associated software  Sedacom  etc    When the device  is used without software in first instance  this cable need to be preserved and kept in    secure place in case the need of using the system with a software is required in the  future  In this last case  if the user lost the cable  a new one should be purchased to his  local sales delegate  ref  CONRS232   The warranty time of this cable is the same than  the warranty time of the device        Tail flick meter  17    Panlab             13  CHANGING SAFETY TIME    If there is no animal response  the light automatically cuts off after 20 seconds to  prevent harm to the animal s tail  This safety time can be modified with internal  micro switches as follows     149250961  AREA      32  259184                                                                                        a u    a 20 seg   12 3 4  EIN E m 1559  12 3 4  E u 10 seg   1 2 3 4   5 seg                       ai  NE     E       3       Figure 15  Changing safety time  
16. igrosas en aparatos el  ctricos y electr  nicos   ROHS    Restriction of the use of certain Hazardous Substances in electrical and  electronic equipment  ROHS    Restriction de l utilisation de certaines  substances dangereuses dans les equipements   lectriques et   lectroniques   ROHS    2006 42 EC Directiva mecanica   Machinery directive   Directive m  canique    Para su evaluacion se han aplicado las normas armonizadas siguientes   For its evaluation  the following harmonized standards were applied   Pour son   valuation  nous avons applique les normes harmonis  es suivantes     Seguridad   Safety   S  curit    EN61010 1 2011   EMC  EN61326 1 2012 Class B  FCC  FCC47CFR 15B Class     Safety of machinery  EN ISO 12100 2010    En consecuencia  este producto puede incorporar el marcado CE y FCC   Consequently  this product can incorporate the CE marking and FCC  C    En consequence  ce produit peut incorporer le marquage CE et FCC     En representacion del fabricante   Manufacturer   s representative   En repr  sentation du fabricant  Carme Canalis     k                General Manager p  Panlab s l u   a division of Hakvard BioScience          Cornell   de Llobregat  Spain  15 10 2014       Tail flick meter    22    Harvard    Apparatus    Panlab  H        Note on environmental protection     After the implementation of the European Directive 2002 96 EU in the national legal system  the  following applies    Electrical and electronic devices may not be disposed of with domest
17. ion     The cables and connections are listed below     a FROM CABLE  LE7106 FOCUS DBg to 4 pins cable    LE7106 FOOT SWITCH   FOOT SWITCH 6 35mm Jack mono cable  LE7106 RS 232 Computer Com Port   RS 232 cable       Tail flick meter    12    Harvard  Apparatus    Panlab           9  CHANGING THE LAMP    This type of halogen lamp has a very long service life  Nonetheless  if you have to  change one please follow these instructions     1  Toremove the cover  press down and turn it clockwise     Do not unscrew        Figure 10  Remove the top cover     2  Then proceed to extract the bulb and unscrew the electrical contacts     3  Change the light bulb  screw again the contacts and place it in its correct  position inside the lamp             Figure 11  Unscrew the wires        change the lamp     4  Lastly place the cover in its correct position       Tail flick meter    13    Panlab       tove    10  WORKING WITH THE EQUIPMENT    1  Turn the control unit ON  ensuring correct connection between it and the  experimentation unit     Focus    10   2  Adjust the INTENSITY to the desired heat  using the    selector    3  Move the lamp to its back position    4  Prepare the animal  placing it in the restrainer  Then place the restrainer on the    platform with the help of the 2 small metal cylinders  and leave the animal s tail  over the phototransistor        Figure 12  Preparation of the animal     5  Move the lamp to its most frontal position     6  Press e The lamp and the chronom
18. or  the dial has a brake  that prevents selecting values below 10     Lamp cannot be calibrated by the user   As option there is a calibration certificate  that must be done in factory and it   s not  cost free        19    Panlab       ever        15  PREVENTIVE MAINTENANCE  WHEN  EXPERIMENT   NECESSARY  CLEAN V SHAPED  ACCESORY  CLEAN EXPERIMENTATION  UNIT SURFACE  RESTRAINER CLEANING           CHANGE SAFETY TIME     CHECK CABLES  CONNECTION      See chapter 9     See chapter 13     Tail flick meter    20    Panlab H Harvard    16  TECHNICAL SPECIFICATIONS          POWER SUPPLY  Input voltage   Frequency   Fuse   Maximum Power   Conducted Noise     Universal input 100 240V AC   50 60 Hz   2 fuses 5mm 20mm 2   250V Fast  36W   EN55022  CISPR22 CISPR16 class B       ENVIRONMENTAL CONDITIONS  Operating temperature     Operating Relative Humidity     Storage temperature     10  C to  40  C  0  to 85  RH  non condensing  o C to  50  C  non condensing       COMUNICATIONS OUTPUT                Standard Interface  RS232C  Connector  Delta 9 contacts female connector  FRONT PANEL  Beam Intensity  Adjustable in the interval 10 99  Display  4  Digits  Max  Time  99 99 s limited to 20 seconds  Precision  0 015  CONNECTOR FOCUS  Pin Function  A  5V  B Lamp  C Input  D Lamp  CONNECTOR R5232  Pin Function  3 Txd  5 Gnd  LAMP  Model  Halogen OSRAM 64607  Voltage  8V  Power  50W    Operative life   Number of measurements   Temperature error      never use other brands or lamps     4500 h   
19. transport    D  Place the equipment on a flat surface and leave at least 10 cm of free space  between the rear panel of the device and the wall  Never place the equipment  in zones with vibration or direct sunlight    E  Once the equipment is installed in the final place  the main power switch must  be easily accessible    F  Only use power cords that have been supplied with the equipment  In case that  you have to replace them  the spare ones must have the same specs that the  original ones     G  A Make sure that the AC voltage in the electrical network is the same as  the voltage selected in the equipment  Never connect the equipment to a  power outlet with voltage outside these limits       For electrical safety reasons you only can connect equipment to    power outlets provided with earth connections    This equipment can be used in installations with category ll over   voltage according to the General Safety Rules     WARNING    The manufacturer accepts no responsibility for improper use of the equipment or the  consequences of use other than that for which it has been designed     Tail flick meter    Panlab H ed    PC Control    Some of these instruments are designed to be controlled from a PC  To  preserve the integrity of the equipment it is essential that the attached PC  itself conforms to basic safety and EMC standards and is set up in  accordance with the manufacturers    instructions  If in doubt consult the    N information that came with your PC  In common wit
20. zioni per protezione ambientale     Dopo l implementazione della Direttiva Europea 2002 96 EU nel sistema legale nazionale  ci sono  le seguenti applicazioni      dispositivi elettrici ed elettronici non devono essere considerati rifiuti domestici    consumatori  sono obbligati dalla legge a restituire   dispositivi elettrici ed elettronici alla fine della loro vita utile ai  punti di raccolta collerici preposti per questo scopo o nei punti vendita  Dettagli di quanto riportato  sono definiti dalle leggi nazionali di ogni stato  Questo simbolo sul prodotto  sul manuale d istruzioni  o sull imballo indicano che questo prodotto    soggetto a queste regole  Dal riciclo  e re utilizzo del  material o altre forme di utilizzo di dispositivi obsoleti  voi renderete un importante   contributo alla protezione dell ambiente                  Nota      Protecc  o Ambiental     Apos    implementag  o da directiva comunit  ria 2002 96 EU      sistema legal nacional     seguinte  aplica se    Todos os aparelhos el  ctricos e electr  nicos nao podem ser despejados juntamente com o lixo  dom  stico Consumidores est  o obrigados por lei a colocar os aparelhos el  ctricos e electr  nicos  sem uso em locais p  blicos especficos para este efeito ou no ponto de venda  Os detalhes para  este processo sao definidos por lei pelos respectivos pa  ses  Este s  mbolo no produto  o manual de  instruc  es ou a embalagem indicam que o produto est   sujeito a estes regulamentos  Reciclando   reutilizando os
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung SAMSUNG PL70 Uporabniški priročnik  T2QuickNet  NOTICE URGENTE RELATIVE À LA SÉCURITÉ D  06_regedilcarugate - Università degli Studi di Pavia  取扱説明書 - 三菱電機  IP Card Reader Interface User Manual  UG_Mimic V5_Ver.01.01.03_EN.book  Manual - Goldair  beurer MG 55    Copyright © All rights reserved. 