1. Y to chose setting options System time enter the page of system time setting and use the button A V to chose the number you want to modify input the number with keypad and press button OK to save it Time Setting Form Year Month Day Hour Minute Timing Setting group 1 to group 6 to set timing arm disarm and arm mode Enter the page of system time setting use the button A V to chose a group of timing time and press button OK to save it Timing Task Out Arm system start our arm automatically at the timing time Home Arm system start home arm automatically at the timing time Disarm system disarm automatically at the timing time Timing Time input the timing time with the keypad in the form of hour minute Timing Status to set whether this timing group is available Use the button A V to chose on off Default Setting Off g Change Password Enter system setting page and press button A V or keypad 9 to chose icon press button OK input the new password with keypad press button OK to save it and then press button MENU to return to the main menu page 1 5 Detector Management Please enter the correctly password original password 1234 and press the button MENU Jon the panel before any operation Two beeps show that the operation is successful The LED indicates lights of Arm and Disarm will be on at the same time You can see 6 icons in the screen Press button A
2. c Make the obstacles and floating objects away from the detecting area such as the clothes durtain and flowers d Make the detector steadily installed without any shake and trembling e Keep away from the direct sunlight irradiation f lf the light in the PIR keep on it shows battery fails So please replace it as soon as possible 1 4 Basic Setting Direction System Setup Please enter the correctly password original password 1234 and press the buttonf MENU Jon the panel before any operation Two beeps show that the operation is successful The LED indicates lights of Arm and Disarm will be on at the same time You can see 6 icons in the screen Press button A V or keypad to chose corresponding icon Then press button OK to do detailed setting Please press button OK Jto save after you finished your operations The system will show saved in screen and with two beeps Four short beeps shows failure Please press MENU IJ to try it again Exist System Setup Please press button to end the programming status after you finish your operations System will exist automatically if there is any order within 30 seconds a Record alarm message Enter system setting status and press button A V or keypad 5 to chose icon D 1 Please chose Record or press button OK System will show Recording and recording time in screen Facing to the microphone in the left side of the host to record alarm mess
3. You can see six icons in screen Please press button A J V Jor keypad 1 to chose icon H and then press button OK to enter the history research page Search records To search system arm disarm and alarm records Every page shows one record You can press button A V to page down The system can store 99 history records Press button MENU to returen Delete all records Press button OK to confirm and you can see Deleted in screen Press button to exit and the system turn into the standby status 3 System Reset Input 0000 when the system is in standby status Three seconds later you will hear two beeps It means system reset successfully All the information about wireless detectors learning code and alarm telephone numbers is deleted All setup options restore to factory defaults and the password comes back to the original 1234 IV Technology Parameter Standby Current 80mA Working Current 500mA Power Supply DC9 12V Operating Temperature 10 C 40 C GSM Frequency 900 1800 1900 MHz Receive Coding ASK Receive Frequency 315 433 MHz Receive Sensitivity 5mV m Anti interfere 1V m 20 1KMHz 10 Remote Control Distance No obstacle 100m Se et eS e a a 11 Acceptable wireless detectors 99 V Whole Kit List Alarm system alarm host 1 pc 4 keys remote controller 2 pcs Wireless door sensor MC 02B 1pc Power supply 1 pc Wireless PIR detector 1 pc Telephone line 1 pc Al
4. 9 outside line call number c Conventional System Setup Enter system setting status and press button A V or keypad 2 to chose icon B press button LOK and then press button A VW to chose options as followings User s account to set user s ID in alarm receiving center 4 numbers 0001 9999 NOTE It is not necessary to setup by the individual user Ringing times to set remote control ringing times OO0 12 times OO means turn off the remote control function Default Setting 8 times x lt Siren ring time to set siren ring time when alarming 00 30mins 00 means turnoff the hooter whistle function Default Setting 1 minute Delay alarm time to set the host alarm time between the host receive detector s signal and start to alarm 00 30sec 00 means turnoff the alarm delay function Default Setting 30sec Delay arm time to set the host arm time between the host receive controller s signal or remote arm order and start to arm 00 30sec OO means turnoff the arm delay function Default Setting 30sec d Function on off setup i Enter system setting status and press button A J Y or keypad 3 to chose icon press OK and then press button A V to chose options as followings 8 Line Cut alarm to set whether hooter whistle alarm when external line error Press button A V 1 to chose On Off Default Setting Off Wired Input Port to set whether the host enables the
5. system is in out arm status Out Arm Immediate first press key Out Arm and then press key Emergency Alarm within 3 seconds The light STATUS is red without flash the icon LA will be showed in screen The system is in out arm status A Under Out Arm status the light STATUS is red without flash and the icon will be showed in screen when the wireless detectors in external defense zone are triggered and the host alarming Home Arm press key Home Arm a voice of beep can be heard from host the light of home arm is on and the icon R will be showed in screen It means the system is in Home Arm status A The light STATUS is red without flash and the icon NS will be showed in screen when the wireless detectors in inner defense zone are triggered and the host alarming Disarm press key Disarm all the lights will be turned off All the detectors triggered won t make the system alarm except emergency detectors Such as emergency button smoke detectors and so on Emergency Help press key Emergency Alarm the host will alarm at once whenever it is in arm or disarm status The system will make calls to users The siren will also alarm The light STATUS is red without flash and the icon amp SY will be showed in screen 2 3 History search Input the correct password on the keypad original password 1234 and press button MENU two beeps will be hear from the host The home arm and out arm lights are turn on
6. Intelligent GSM PSTN Auto Dial Alarm System Users Manual Before use please have a through reading of this book for right usage Forward Welcome to use intelligent GSM PSTN auto dial alarm system with powerful functions Large LCD screen with English menu navigation function make the operation easier It can call 5 users numbers by GSM PSTN dual network PSTN first when it alarming Listening in function is available for users by using mobile phone and telephone This alarm system is widely used for security protecting data surveying and remote monitoring in families shops villas financial offices residential estates and department of electricity petroleum coal government public security and so on Please read the manual carefully in hopes that the product could serve you well Xs SR CAUIEN OS EAE EE PEE E E EE T EEE A E EE Il Main Panel Button s Function and Ports Introduction I Operation Manual 000000000000s00s0sssss0ssssossssessseesoeoo 1 Installation Setting esesseseesecsessessesescecsoeseesessesoes 1 1 Basic Installation Direction cccccccccccccccecs 1 2 Power on Direction cccccccccccccccccccccccccccccecs 1 3 Installation Direction ccccccccccccccccccccceccs 1 4 Basic Setting Direction ccccccccccccccccccccccccecs 15 Detector Management ccceccccccccccccssccces De User GHG a a a a eet 2 1 Test the a
7. V or keypad 6 to chose icon then press button OK to enter detector administration page Total number of sensors show total number of wireless detectors saved in system include remote controller Arm Zone show serial number of wireless defense zone Total 99 01 99 You can change it with keypad a Add new detectors Input the defense zone serial number of the wireless detector you need add in defense zone serial number blank press button A V to chose Start codin and press button OK to save it You can see the total number of wired wireless detector have been saved in this defense zone in the first line of the screen Please trigger the wireless detector need to learn into this defense zone such as separate door sensor and press any button on the remote controller Two beeps from the host show learning code successfully The total number of detectors will add one You can add more wireless detectors in each defense zone But the total number can t over 99 Two beeps from the host but the total number won t change if the wireless detector has been saved Press button MENU J after learning code System will exit automatically if there is no wireless signal to learn within 2 minutes b Change wireless detectors defense zone If you want to move a saved wireless detector into another defense zone please do the same steps as add new detectors The formal defense zone can delete this
8. age The message should be short and clear For example This is room X X building X X and zone X X asking for help The system will exist with two beeps automatically after 10 seconds 2 Chose PLAY and press button OK you can hear the voice you record in the telephone connected with the host Record again if you want to change the voice b Set user s and alarm center phone numbers to receive alarm Enter system setting status and press button A VW or keypad 4 to chose icon 2 groups of receiving alarm center number number to connect with the alarm center NOTE It is unnecessary to setup this Number by the individual user 6 groups of users number number to receive alarm for users mobile phone or telephone number Press button A V to chose the number group you want to modify or delete and then press button OK Modify input telephone number or mobile phone number with the host keypad and then press button OK to save it The screen will show Saved Delete Press button OK and the screen will show Deleted NOTE The host will make a voice of di for three times in every 25 seconds if there is any receive alarm number Each group of phone number cannot over 16 digitals Please dial the Out No before the receive alarm number if your system use extension number E g If you should dial 9 when you make an outside line call please set the receive alarm number as
9. alized battery II Main Panel Button s Function and Ports Introduction 00 00 7 7 Eer inat L Cis Ld SIM PHONE LINE POWER HORN RELAY GND 1 GND 2 GND 3 C Power Socket 2 Horn Socket 8 Cable Outlets 4 SIM Card Seat Phone Line Socket External Line Socket AWAY HOME ALARM POWER Tull on 10 3 8 14 26 9 8 7 1 Status Indicator Lamp 2 LCD Screen 3 Power Switch 4 Number Button 5 Programming Button 6 Emergency Alarm 7 Disarm 8 Home Alarm 9 Out Alarm 10 Microphone 11 Function Button NOTE 1 SIM Card Slot click the yellow button near the SIM card seat take out the card seat put a effective SIM card in it and insert it back 2 Power Socket connect 12V 1 5A DC inner core is positive shell is negative 3 10 Core Socket lao CD 3 GND 2 GND 1 BLA YT The first and second ports are internal power source output pin load capacity 12V 300mA output The third and fourth ports are internal relay exit They are normally opened They will keep closed for 2 minutes when alarming They can also link the power video and so on when working The fifth and sixth ports are wired input1 The seventh and eighth ports are wired input2 The ninth and tenth ports are wired input3 These 3 wired ports will trigger alarm when they are open collector I Operation Manual 1 Installation Setting 1 1 Basic Installation Direction 1 Prepa
10. arm siren pc User s manual 1 pc
11. installation position should be far away with huge metal objects and wireless devices c The host should be installed in a shelter d Turn on the host and it will come into the working state after 2 minutes warming up 2 Installation of Door Sensor 2 ai Low Power LED Fj gt We define the Magnetic door window contact for 2 parts part A and part B First pack the battery into the part A and then according to the show of sketch map to fis part A and part B with screws on the monitored door window It is better if the distance between them is closer lt 15mm between part A and part B NOTE a Magnet should be close to signal status and make the transmitter box and magnet as close as possible lt 10mm b In order to get the best receiving distance you should pull the antenna and make it upwards c If the indicator lights of door sensor are still blinking it shows battery fails So please replace it as soon as possible 3 Installation of Wireless PIR PIR Sensors are used for detecting if someone moves within in a certain place Fix it on the wall 2 2 2meters high and you should adjust the position to make it face to the defense zone Window 10 30 2m 2 2m NOTE a Adjust the detecting angle try to make the detecting window plumb to the direction of people s walking b Keep away from the heat or air conditioner blowing and air convection area close the window amp door when alarm the detector
12. larm function ccccccccccecs 2 2 Control the Monitor with Wireless Remote Controller 2 3 History Researchere cnc heestantesaasonceatesvelesaeties nies JOYS RESE asda sccucnasey ous EE E IV Technology Parameter ccssccssccssccccccccccescceccesccees Ve Whole Kit Lisl ists Sie an a aaa VI Storage Transportation and After Services sscesecceeees I Main Panel Button s Function and Ports Introduction E 10 11 12 13 Dual network GSM amp PSTN alarm function alarm information more safe Intelligent recording PSTN first Large LCD screen with menu navigation function by which users can operate it easily and directly Full function keypad Users can complete all the operations on the host 99 wireless zones and 3 wired zones each zone can be programmed independently Learning code way for wireless detector each zone can connect with all kinds of wireless detector Powerful Black Box function which can store and search 99 arm and disarm historic alarm information Can set 6 groups of fixed time for arm and disarm Can record alarm voice repeatedly and check it on site Hint the function of telephone line error Can control the system by calling in such as arm disarm listening in and so on Alarm first and grab line alarm Built in high performance rechargeable battery can make sure the host still work when the electricity is cut off Use of time save chip speci
13. re a useful SIM card 2 Put the SIM card in the card seat on the back of the host 3 Connect with telephone line 4 Prolong the antenna and connect all the wired detectors with the host if any 5 Connect with power and turn on the host 6 Power light turns green and GSM antenna icon T is flashing means the host is checking the SIM card and searching the GSM signal This icon won t flash and the signal strength icon Tull will come out in a few seconds then equipment start working 1 2 Power on Direction LED Light Status Explanation LED Light LED Status System Working Status Didn t turn on the host didn t plug the power no Power power in built in battery Rea o fh alarm status Red aa Alarm memoring can be closed after arm again Alert remove Off HOME Red flash slowly 30 s later Out Arm with delay time red on LCD Icons Introduction Without flash GSM module and SIM card normal Flash GSM module and SIM card error Y gt 3 i Show GSM network signal strength Flash External telephone line error Without flash External telephone line normal Programming Status Phone number setting Without flash Operation records Programming Status History Checking i o O peee 1 3 Installation Direction 1 Installation of the Host a Try to install the host in the center of the defense zone and prolong the antenna for getting more wireless signal receiving distance b The
14. when answering the alarming call and press any key to stop Press to open listening in function If you press the host won t call other users and turnoff the siren alarm The host will continue to call other users if you don t press c Users can use every telephone and mobile phone to call SIM Card s number in the host or telephone number linked to the host to control the host remote The host will answer the call automatically after ringing times set before Two beeps can be heard after you input password and it shows you can make remote control Dial 1 Arm Dial 2 Disarm Dial 3 Play record voice in 10 seconds Dial 4 Turn on the siren scene alarm Dial 5 Turn off the siren scene alarm Dial Open listening in function Dial Exit remote control and the host hang up If you failed password in three times or there is any operation in 30 seconds during the remote control the system will exit remote control automatically and the host will hang up 2 2 Control the Monitor with Wireless Remote Controller Out Arm Emergency Arm Disarm Home Arm The remote controller has 4 keys Disarm Out Arm Home Arm and Emergency Arm Out Arm press key Out Arm a voice of beep can be heard from host the light STATUS is red flash 30 seconds later turns green without flash the icon A will be showed in screen The
15. wired input port Press button A V to chose On Off Default Setting Off NOTE Please disable all the wired input ports when there is no wired detector linked with to make the host work steadily e Host Zones Mode Setup Enter system setting status and press button A IM V Jor keypad 7 lto chose con O then press OK input zone number with keypad in the zone number blank Press button A VW to chose wired or wireless press OK and press button A V or keypad to chose zone mode and then press OK to save There are 5 modes for each zone as following 1 Close no matter arm or disarm the host won t alarm when detectors in this zone are triggered 2 Immediate host will alarm immediately when detectors in this zone are triggered in arm mode 3 Delay host will alarm after the delay time when detectors in this zone are triggered in arm mode 4 Emergency no matter arm or disarm the host will alarm immediately when detectors in this zone are triggered 5 Home in this mode the host won t alarm even if detectors in this zone are triggered It will alarm when at Away Home mode Default Setting for all modes Immediate Note wireless zone can be set 01 03 and wired zone can be set as 01 99 f System time and the time of timing arm disarm setup Enter system setting status and press button A I V Jor keypad 8 Jto chose icon 4 press button OK then press button A
16. wireless detector automatically c Delete lost detectors If the host needs to delete lost sensors in wireless zones such as remote controller Input the defense zone serial number of the wireless detector you need delete in defense zone serial number blank press button A J V to chose DEL this sensor and press button OK to save it Deleted will be showed in screen e Press button A Y to chose delete all if you want and press button OK to save it Deleted will be showed in screen The total number of detectors will be showed as 00 2 User Guide 2 1 Test the alarm function When the host is powered it will keep the status in last time power off arm disarm Users can use wireless controller to arm Under arming status the arm red light will be on without flash and the icon E UW will be showed in screen The host will send alarm message to users when wireless detectors are triggered Such as wireless PIR detector wireless door sensor emergency button on the remote controller a If the host has SIM card in and linked to a telephone line When it s alarming the host will dial to alarm receiving center and users first through telephone line If the host has SIM card in but no telephone line linked or the telephone line has faults When it s alarming the host will dial to alarm receiving center and users through GSM network b Users can hear the alarm voice which recorded before