1. and for Croatian language Function 11 Set date and time Set the date and time which are shown on the display Set date and time with master code Enter the master code and press Press 11 and Move to the beginning with Insert the date and time and press Function 12 ECO mode Set the controller to sleep mode By default the ECO mode is on after five minutes Set ECO mode with master code Approach the master card and remove it after 12 double beeps The controller will start to beep every second Each beep means one minute more until the ECO mode max 90 minutes In the ECO mode the device uses less power to work You can wake up the controller with any action performed on it If you approach a user card before 1 double beep you turn the ECO mode off Set ECO mode with master card Enter the master code and press Press 12 and Insert the time utill ECO mode in minutes max 90 minutes and press To disable ECO mode insert 0 and press In the ECO mode the device uses less power to work You can wake up the controller with any action performed on it Function 13 Delete all Reset delete all data to default Delete all with master card Approach the master card and remove it after 13 double beeps The controller will start to beep every second Approach a user card after three beeps Delete all with master code Enter the master code and press Press 13 and Press 3 ande Function 14 List Ove
2. take the position of a deleted card Function 7 Delete a lost card Delete the previous card on the list Use this function if you lost a card and you wish to delete it from the controller In order to use this function you must maintain a list of registered cards and codes arranged by order of registrations so that you can find the card or code which was registered after the lost one Delete a lost card with master card Approach the master card and remove it after 7 double beeps Within a period of three seconds approach the user card which was registered after the lost one This will delete the lost user card Next registered card or code will take the position of a deleted card Function 8 Display brightness Adjust the intensity of display brightness Set the brightness with master card Approach the master card and remove it after 8 double beeps The controller will start to beep every second Each beep is presenting the intensity of the display brightness which is selected with a user card Brightness intensity range is from 1 to 9 Set the brightness with master code Enter the master code and press Press 8 and Enter the number of brightness intensity range is from 1 to 9 and presse Function 9 Switch to Wiegand 26 bit table reader access controller or back to standalone controller Switch the controller to a Wiegand 26 bit reader a table reader or an access controller Table reader sends a card number through RS
3. the master cards Turn the power supply on 2 beeps indicate power on One by one approach two cards you will use as a master cards 3 beeps indicate a successful registration The first two cards registered become master cards All the other cards will be registered as users user cards You can register only one master card if you approach the same card twice Usage of master card If you hold the master card in front of the controller every 2 seconds a double beep is heard The number of double beeps indicates the programming function Usage of master code You need to enter the master code and number of the function Then enter confirmation number or exact value which is needed PROGRAMMING FUNCTIONS WITH MASTER CARD AND CODE Master Card Code Change master codes and master cards Register or delete user cards or codes Pulse time Duration of active output or toggle mode Ye Function Description Yes till pre alarm Y No Y Yes Y oo o E s zo s 3s s Switch to Wiegand 26 bit table Yes Yes S Yes reader or access controller 10 o o o o 42 s Set date and time ECO mode Delete all Y Yes List No Sound off on alarm output off on door status switch input NC or NO set time in minutes or seconds Reset o Z o Y Description of programming functions e Set language N e Function 0 Change master codes and master cards The default master code is 1 2 3 4 It is necessary to cha
4. 485 To change the controller back to a standalone controller from an access controller you need to make a brainwash with the JantarV7 software Switch with master card Approach the master card and remove it after 9 double beeps The controller will start to beep every second Each beep presents a different function which is selected with a user card Standalone controller Approach a user card before 1 beep Wiegand 26 bit reader Jantar Approach a user card after 1 beep The reader sends a card data at once and pressed buttons separately This is used in Jantar s systems so that the controller distinguishes between a card and code Wiegand 26 bit reader World Approach a user card after 2 beeps The reader sends a card or code data at once This is used in systems of other producers Access controller Approach a user card after 4 beeps Table reader Approach a user card after 8 beeps Switch with master code Enter master code and press Press 9 and For Standalone controller Press 0 and Wiegand 26 bit reader Jantar Press 1 and Wiegand 26 bit reader World Press 2 and Access controller Press 4 and Table reader Press 8 ande Black line Function 10 Set language Change language from English to Slovenian or Croatian and back Set language with master code Enter the master code and press Press 10 and Press 1 and for English language 2 and for Slovenian language 3
5. REGIS M 3 Standalone access or time and attendance controller 17 07 12 28 57 Jantar REGIS M 3 STANDALONE ACCESS or TIME AND ATTENDANCE CONTROLLER The Regis is a controller with built in proximity card reader and 5 LCD Capacitive touch screen display It is designed for residential and business buildings offices shops etc The controller can has 13 56MHz reading frequency As a standalone controller the entire set up procedure is carried out with master card or code User cards and codes can either be registered or deleted The controller allows access for up to 500 users 1 master card 500 user cards or codes As an access controller the entire set up procedure is carried out with the software The controller allows access for up to 16000 users If you bought the controller in time and attendance kit then inputs and outputs cannot be controlled It can also be used as a Wiegand 26 bit reader if needed The SDK is also available for this controller If a user or software producer wants to develop its own application please contact us TECHNICAL DATA REGIS M 3 Reading frequenc Reading distance Current consumption Dimensions mm Protection Operating voltage Operating temperature SF A 18 wires 20cm Display TFT capacitive touch Tamper Display resolution Humidity Memory 800 x 480 10 80 non condensing 500 or 16000 cards or codes Push button Outputs max ten hours Communi
6. Tamper is ON Door status switch input normally opened NO Time is set in seconds Before 1 beep Press 0 and After 1 beep Press 1 and After 2 beep Press 2 and After 3 beep Press 3 and 5 2014 www codeks eu REGIS M 3 Standalone access or time and attendance controller After 4 beep Sound is OFF Tamper is OFF Door status switch input normally closed NC Time is set in seconds Sound is ON Tamper is OFF Door status switch input normally closed NC Time is set in seconds Sound is OFF Tamper is ON Door status switch input normally closed NC Time is set in seconds Sound is ON Tamper is ON Door status switch input normally closed NC Time is set in seconds Sound is OFF Tamper is OFF Door status switch input normally opened NO Time is set in minutes Sound is ON Tamper is OFF Door status switch input normally opened NO Time is set in minutes Sound is OFF Tamper is ON Door status switch input normally opened NO Time is set in minutes Sound is ON Tamper is ON Door status switch input normally opened NO Time is set in minutes Sound is OFF Tamper is OFF Door status switch input normally closed NC Time is set in minutes Sound is ON Tamper is OFF Door status switch input normally closed NC Time is set in minutes Sound is OFF Tamper is ON Door status switch input normally closed NC Time is set in minutes Sound is ON Tamper is ON Door status s
7. cation RS485 Configurable buttons Selectable colors Inputs Keypad CONNECTION WIRES Wire Color Description Wiegand 26 bit Specification 9 14V DC Max 0 5A 3 green El strike output Data 0 Active GND Alarm output Data 1 Active GND 5 yellow Door status switch input Buzzer Active GND input B Push button input a 7 light blue RS485 A line RS485 B line ETHERNET WIRES Wire Color Description Specification TXP Black line EXTERNAL READER WIRES Wire Color Description Specification Ground Power supply The controller need s external power supply to operate The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes or two 12V magnetic locks 0 5A If you will use it as a standalone controller and low consumption electric strike 0 25A you can use power supply Spider W5 Voltage drops and cable signal interferences When you connect the controller use cable with a diameter of at least 0 22mm If the cable length exceeds 25m use one twisted pair of UTP cables for the positive pole and one for the negative pole The cable length between power supply and the controller should not exceed 50m Take into consideration that a 0 22mm cable has a resistance of approximately 9 ohm per 100m The power supply at the end of cable should be a minimum of 9V If you are using el strike it is highly recommended that the voltage drop is calculated At gr
8. d to ground This can be changed with function 5 negate output for el magnet Environment Do not install the controller on in a place where it can come in contact with water You must assure good cable joints protected against moisture otherwise corrosion may damage the controller Damage in such cases is not covered by the warranty AS A STANDALONE CONTROLLER The entire set up procedure is carried out with the master card or code You can register two master cards and two master codes They are saved on four positions which are independent of the positions of saved user cards and codes Master cards are saved in 1 and 2 position Master codes are saved in 3 and 4 position The master cards and codes cannot be replaced or duplicated After registration the master cards and codes should always be kept ina secure place You cannot change any setting without them and neither can we Keep that in mind when storing the master cards and codes 5 2014 www codeks eu REGIS M 3 Standalone access or time and attendance controller The default master code is 1 2 3 4 and is stored in positions 3 The maximum master and user code length is 9 digits Master code must be CHANGED for security reasons because the default one is written in the controllers manual and with it anybody can set himself his own code to open YOUR door Programming with the master card and code First connection to the power supply and registration of
9. eater distances a thicker cable of 0 5mm or more should be used wherever possible If the load is for example 0 5A with el strike then on the 0 22mm cable voltage drop will be 4 5V at 100m For the device with 60mA consumption the voltage drop is 0 5V Reading distance depends on where the controller is installed The presence of metal or interferences can significantly reduce the reading distance DO NOT install the controller directly on metal surfaces and or cover it with a metal cover It is not recommended to install controllers closer than 30cm from each other in any direction Otherwise it may result in inaccurate readings or indeed in the controller not reading at all For the Regis M 3 to comply with EMC directives CE you have to put ferrite core on the cable as close to the controller as possible making two turns Inputs outputs and environment Inputs Inputs are realized with opto isolators The input is active when pulled to ground with an open collector transistor or mechanical switch which is connecting the input pin of the controller to the Ground Outputs Output has a pre installed protection diode for an inductive load It is also protected from current overload The best way is to use a 0 25A el strike or a 0 5A el magnet which has to be connected to the same positive pole as the controller Connect the negative pole to the door strike output wire 3 When the output is active it is pulle
10. n M box Frequency 13 56MHz for CODEKS Integrated Ethernet Horizontal holder Standalone access or time and attendance controller in M box Frequency 13 56MHz for CODEKS Integrated Ethernet Vertical holder Integrated intercom REGIS M 3 3P NET AV OTHER Warranty only applies when the controller Regis is used with power supply or and communication converter from the Spider family Please read through our warranty and disclaimer statements Connection scheme and additional support for the use of this product can be found on http www jantar si forum en CONTACT Jantar d o o Kranjska cesta 24 4202 Naklo web www codeks eu SLOVENIA mail sales jantar si 5 2014 www codeks eu
11. nge it for safety reasons You can use only one master code The Master code also enables you to change the master cards Change the first master code on position 3 Enter the default master code 1 and press Press 0 and Press 3 and Enter the new master code and presse Change the second master code on position 4 Enter the master code and press Press 0 and Press 4 and Enter the new master code and press Store the master codes in a secure place Change the first master card on position 1 Enter the master code and press Press 0 and Press 1 and In three seconds approach the new master card Change the second master card on position 2 Enter the master code and press Press 0 and Press 1 and In three seconds approach the new master card Save the master cards in a secure place Function 1 User cards and codes Register or delete user cards and codes With a registered card or code output O0 wire 3 for an el strike is triggered for the time set in the function 2 In the controller registered cards and codes are arranged in order of their registration Every registered card and code is saved to its own position If you save a new card or code to already taken position then the previous card or code will be deleted Black line Register user card with master card Approach the master card and remove it after 1 double beep Within a period of three seconds approach a u
12. oach the master card and remove it after 3 double beeps The controller will start to beep every second Each beep indicates 1 second or 1 minute till pre alarm Duration of the time till pre alarm can be max 120 seconds or 60 minutes When you hear the required number of beeps approach a user card for confirmation Set the time till pre alarm with master code Enter the master code and press Press 3 and Enter the duration of the time till the pre alarm in seconds or minutes max 120 seconds or 60 minutes and press Function 4 Pre alarm and alarm Set the pre alarm time This is the time in which the controller with short beeps alerts you that the door was left open If you don t close the door in the pre alarm time the alarm will be triggered and signaled with long beeps by the controller The time can be set in seconds or minutes Switching time from seconds to minutes and back can be adjusted by using the function 15 Set the pre alarm time with master card Approach the master card and remove it after 4 double beeps The controller will start to beep every second Each beep indicates 1 second or 1 minute of the pre alarm time Duration of the pre alarm time can be max 120 seconds or 60 minutes When you hear the required number of beeps approach a user card for confirmation Set the pre alarm time with master code Enter the master code and press Press 4 and Enter the duration of the pre alarm time in sec
13. oller As a time and attendance controller it is intended to register the employee s arrivals and exits from work lunch break private and business exits sick leave It needs to be set with V7 or CODEKS software In software you need to choose option Time and attendance for controller and reader Set the software according to your requirements time tables users and send the tables The keypad will serve for choosing different time intervals private business Black line The controller switches to access or time and attendance controller when tables are sent by the software or when it is set to mode 4 with function 9 Change the controller s address from 255 to any number between 1 and 254 If you have more controllers on the communication line don t duplicate addresses Add them one by one on the communication line because every controller has address 255 by default Communication Ethernet Connect the controller to the computer through your LAN via marked wires Use at least UTP CAT 5e cable Adjust network settings of the controller using the Codeks Device Manager software so that it will function properly in your network Please consult Codeks Device Manager s manual RS485 Connect the controller to the computer with one of the power supplies with communication converter from the Spider family Spider W5 USB Spider W5 NET Spider W40 NET The RS485 communication bus is used between the controlle
14. onds or minutes max 120 seconds or 60 minutes and press 5 2014 www codeks eu REGIS M 3 Standalone access or time and attendance controller Function 5 Negate Switch output state This function is used when you connect an electric strike or electric magnet which needs power supply to remain in locked state Switch output state with master card Approach the master card and remove it after 5 double beeps Within a period of three seconds approach a user card The output state will be switched from the current one Switch output state with master code Turn on the negated output Enter the master code and press Press 5 and Press 1 and Output state will be negated Turn off the negated output Enter the master code and press Press 5 and Press 0 and Output state will be switched to default Function 6 Delete a lost card Delete the next card on the list Use this function if you lost a card and you wish to delete it from the controller In order to use this function you must maintain a list of registered cards and codes arranged by order of registrations so that you can find the card or code which was registered before the lost one Delete a lost card with master card Approach the master card and remove it after 6 double beeps Within a period of three seconds approach the user card which was registered before the lost one This will delete the lost user card Next registered card or code will
15. rs and Jantar software Up to 128 controllers can be lined up into one communication line The maximum length of the communication line is 1000 cable meters It is recommended that you use an FTP or S FTP cable Only a serial connection of controllers in a single communication line is allowed Star parallel connection is not allowed All shields of S FTP cables must be wired together and at one point connected to the earth Individual connections to the earth are not allowed Do not connect the shield of the cable to the ground of the controller In the event of problems in communication a termination resistor needs to be added We recommend using 120 Ohm resistors on each side of the cable Converters are on the RS485 side protected with slow blow fuses and transient voltage suppressors Changing back to standalone controller In the Codeks Device Manager software do the Brainwash of the controller Address of the controller s switches back to 255 ORDERING CODES REGIS box card software Box M Card 3 reading frequency 13 56MHz cards 3P high secure access control hardware Communication NET Ethernet connection Holder V vertical H horizontal AV vertical Description Standalone access or time and attendance controller in M box Frequency 13 56MHz for CODEKS Integrated Ethernet Vertical holder REGIS M 3 3P NET V REGIS M 3 3P NET H Standalone access or time and attendance controller i
16. rview of the positions where cards and codes are saved Cards are marked with C Codes are marked with K List overview with master code Enter the master code and press Press 14 and You can move through the list with UP and DOWN arrows Function 15 Sound alarm output door status switch input NC or NO set the time in minutes or seconds function 2 3 4 Turn on off the sound beep which is heard when a card is registered as a pre alarm and alarm Turn on off the accelerometer which triggers the alarm output output1 O1 wire 4 when the controller is moved Set the Input0 I0O wire 5 to normally closed NC or normally opened NO default Set the time in functions 2 3 4 in minutes or seconds Set with master card Approach the master card and remove it after 15 double beeps The controller will start to beep every second Each beep presents a different function which is selected with a user card When you hear the required number of beeps approach a user card for confirmation Set with master code Enter the master code and press Press 15 and Press corresponding number ande Specification Sound is OFF Tamper is OFF Door status switch input normally opened NO Time is set in seconds Sound is ON Tamper is OFF Door status switch input normally opened NO Time is set in seconds Sound is OFF Tamper is ON Door status switch input normally opened NO Time is set in seconds Sound is ON
17. ser card You can register more cards at once if you approach them one by one The user card is now registered and with it you can open output on the controller If the card has already been registered it is now deleted and its position is now empty Next registered card will take the first available position on the list or position of the deleted card When you have register deleted all of the cards wait until the Register user code with master code Enter the master code and press Press 1 and Enter the number of the position and press If you don t enter the position s number just press 4 and the new entered code or card will be saved to a first empty position Enter the a user code and press or approach a new user card A user code or card is now registered and with it you can open output on the controller Delete user card or user code with master code Enter the master code and press Press 1 and Enter the number of the position and press Press 0 and The code or the card from that position is deleted Function 2 Pulse time Duration of active output or toggle mode Set the duration of active output the time in which you can open the door or set output to toggle mode The time can be set in seconds or minutes Switching time from seconds to minutes and back can be adjusted by using the function 15 Toggle mode means if a user card is registered output will remain opened if it was closed or closed if i
18. t was open till next registration Set the duration of active output with master card Approach the master card and remove it after 2 double beeps The controller will start to beep every second Each beep indicates 1 second or 1 minute of active output Duration of active output can be max 120 seconds or 60 minutes When you hear the required number of beeps approach a user card for confirmation Set toggle mode with master card Approach the master card and remove it after 2 double beeps Approach a user card before the first beep Toggle mode is selected Set the duration of active output with master code Enter the master code and press Press 2 and Enter the duration of active output in seconds or minutes max 120 seconds or 60 minutes and press Set toggle mode with master code Enter the master code and press Press 2 and Press 0 ande Function 3 Door status switch input Set the time till pre alarm time in which the door can stay open without triggering the pre alarm and consequently the alarm This function is used when the door status switch on el strike is connected to Input0 IO wire 5 on the controller The input is normally opened NO by default It can be changed to normally closed NC by using the function 15 The time can be set in seconds or minutes Switching time from seconds to minutes and back can be adjusted by using the function 15 Set the time till pre alarm with master card Appr
19. witch input normally closed NC Time is set in minutes Press 4 and lt After 5 beep Press 5 and After 6 beep Press 6 and After 7 beep Press 7 and After 8 beep Press 8 and After 9 beep Press 9 and After 10 beep Press 10 and lt After 11 beep Press 11 and lt After 12 beep Press 12 and lt After 13 beep Press 13 and lt After 14 beep Press 14 and lt After 15 beep Press 15 and Function 16 Reset HARD reset Use it instead off manual reset power off on Reset with master card Approach the master card and remove it after 16 double beeps The controller will start to beep every second Approach a user card after three beeps Reset with master code Enter the master code and press Press 16 and Press 3 and Function F F Device info Access device info with master code If you press F F and then the data of the device will be shown on the display The device s address communication status input voltage firmware version operating mode language temperature inside of the housing communication protocol IP number and accelerometer device position AS AN ACCESS OR TIME AND ATTENDANCE CONTROLLER Access controller As an access controller it is intended for controlling entries exits and passes of users in the system and controlling sliding doors ramp el strike turning alarm on off It needs to be set with V7 or CODEKS software Time and attendance contr
Download Pdf Manuals
Related Search
Related Contents
Specialized Stumpjumper FSR Exp Carbon EVO 29 Modulador Universal Controlable Modulador Universal Controlável Wheel Accessory Products Catalog Manuales - cexpress.com.mx CG-SPTF-R02 GBC 6550X Paper Shredder User Manual G3ZA ナイトスターJP 取扱説明書 - 日立の家電品 KitchenAid KESS908SPB01 User's Manual Copyright © All rights reserved.