Home

USER MANUAL

image

Contents

1. USER MANUAL MODEL NUMBER 1LSP 2LSP 0 3 1 2 liter and 0 5 gallon 2 liter Pump Up Spray Unit English Original Instructions User Manual 0 3 gallon 1 liter and 0 5 gallon 2 liter Pump Up Spray Unit English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT A WarNinG O Read this manual completely and understand the machine before operating or servicing it Read all instructions before installing or operating unit Always wear appropriate personal protective equipment PPE when operating or servicing unit Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet SDS If this unit is modified or serviced with parts not listed in this manual the unit may not operate correctly Never point the discharge wand at yourself another person or any object you do not want covered in chemical Never leave unit unattended while pressurized Always depressurize unit before attempting to remove the pump assembly Always depressurize unit after use as described in the After Use Instructions Always store unit depressurized Do not pressurize unit by any means other than the built in pump assembly Do not modify or remove pressure relief valve Do not use unit if pressure relief valve is not operational Always flush the unit with fresh water for 5 minutes when switching from an alkaline to an acid or an acid to an alkaline A
2. ck the pump assembly for wear and leaks e Check the suction tube and screen for debris and clean as needed e Periodically lubricate the pump seal with a food safe lubricants To lubricate the pump seal raise pump handle and apply 5 to 10 drops of food safe lubricant between pump and pump sleeve NEVER USE LUBRICANTS SUCH AS WD40 Page 30f 4 04142015 User Manual 0 3 gallon 1 liter and 0 5 gallon 2 liter Pump Up Spray Unit English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT PUMP ASSEMBLY Pump Handle Retaining Nut STB80002 ss Air Pressure Relief Valve On Off Control HP PA Carrying Handle JUG BODY Cc gt C TANK2L ITEM NUMBER DESCRIPTION ITEM NUMBER DESCRIPTION HP PA HAND PUMP PUMP ASSEMBLY TANKIL TANK FOR 1L10X 1 2 LITER 0 32 GAL HP SWA HAND PUMP WAND ASSEMBLY FOR SPRAY UNITS TANK2L TANK FOR 2L10X 2 LITER 0 53 GAL STB80002 w SPRAY TIP FLAT FAN 110 DEGREE 0 8 GPM Model Number 1LSP 2LSP Page 4of4 04142015
3. it English READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT Operation Instructions 1 Ensure all air pressure is released from unit by pulling up on the red pressure relief valve Securely hold the unit and unscrew the pump assembly HP PA from the tank in a counter clockwise motion Follow all instructions from chemical manufacturer Fill tank 3 4 of the way with pre mixed solution Note Do not overfill tank with solution Securely hold the tank and screw the pump assembly HP PA back on in a clockwise motion Pressurize the tank by pumping approximately 20 to 25 times or until it become difficult to pump Note The pressure relief valve will leak if the air pressure is too high Do not overfill tank with air To start spraying point the wand assembly at the area you wish to spray and press down on the On Off control to discharge solution Release On Off control to stop Spraying After Use Instructions 1 A Ensure all air pressure is released from unit after each use by pulling up on the red pressure relief valve It is recommended to always empty out remaining solution and run fresh water through the unit to rinse all parts thoroughly after each use and before storage Model Number 1LSP 2LSP Maintenance Instructions Warning Always depressurize unit before performing maintenance To keep your unit operating properly periodically perform the following maintenance procedures e Che
4. lways carry unit by the carrying handle Never lift or carry the unit by the pump handle or the wand Never use unit with hydrocarbons or flammable products Do not exceed a fluid temperature of 100 F 37 C PROTECT THE ENVIRONMENT Please dispose of packaging materials old machine components and hazardous fluids in an environmentally safe way according to local waste disposal regulations A W L 5 Always remember to recycle q Specifications and parts are subject to change without notice Model Number 1LSP 2LSP REQUIREMENTS Liquid temperature range 40 100 F 4 4 37 C Chemical compatibility Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals For more information on chemical compatibility consult the manufacturer or SDS for your product or contact our customer service department SPECIFICATIONS 1L10X 2L10X Power type Manual Chemical pickup type Draws from pre mixed solution Number of products unit can draw from One product Output distance Capacity 0 32 gallons 1 2 0 53 gallons 2 liters liters Discharge wand tip Polypropylene trigger handle with type 80 fan tip STB80002 1 2 ft 0 3 0 6 m Pump seals Viton Page 2 of 4 04142015 User Manual 0 3 gallon 1 liter and 0 5 gallon 2 liter Pump Up Spray Un

Download Pdf Manuals

image

Related Search

Related Contents

The User Manual    Universal Electronics Mary Battery User's Manual  PDFファイル  Philips Inlet filter FC6004  Tondeuse à gazon électrique Electrical lawn mower Tosaerba  

Copyright © All rights reserved.
Failed to retrieve file