Ditec E1A
Contents
1. 13 Application example for rolling shutters When the control panel is used in applications for rolling shutters set JR6 ON connect the N C limit switches in succession to the motor phases make a jumper with the terminals 0 11 12 39 14 Application example for sectional overhead doors Example 1 When the control panel is used in applications for sectional automations set TM MAX connect opening and closing limit switches N C contacts to terminals 0 11 12 select the opening control by means of DIP1 ON select the direction of the movement by means of DIP2 OFF select the closing control by setting 6 gt 4 OFF set JR6 ON NOTE to use electronic control panel in hold to run mode disconnect terminal 9 In this case the opening 1 5 and the closing 1 6 controls operate only if kept pressed if released the automation will stop Automatic closing and radio remote controls are disabled Example 2 Ifyou have connected the self controlled safety edge SOFAT in closing it is possible to make the following connections set TM MAX connect opening and closing limit switches N C contacts to terminals 0 11 12 select the opening control by means of DIP1 ON select the direction of the movement by
2. TM 0s MIN 10 LA MAX 120 s Setting obstacle thrust The control panel is equipped with a safety system that stops motion if an obstacle is encountered during an opening operation and either stops or reverses motion during a closing operation R1 MIN gives maximum obstacle sensitivity minimum thrust R1 MAX disables detection maximum thrust Setting the operating time From 10 to 120 s NOTE with NC limit switch set TM MAX WN ATTENTION disconnect the power supply before adjusting 31 6 2 Dip switch jam Ten Tag DIP2 Direction selection Opens towards right Opens towards left Immediate if 634 0FF NOTE the setting of DIP3 OFF and 654 0FF is recommended for the immediate reclosing of the barriers 63 Jumper Description Enabled NOTE preferably set JR4 ON if the door wing performs an excessive overtravel Overtravel reduction Reduces the overtravel distance for the door wing Disabled Enabled The motor starts with the voltage The motor starts at maximum set with RF power for 1 s Maximum power start Reversal safety switch function With the automation blocked if the contacts 1 8 or 41 8 are open itis possible to activate the opening operation NOTE after the activation of the proximity limit switch closes the opening of the safety contact 1 8 41 8 provokes the STOP during the closing phase 32
3. With the automation blocked if the contacts 1 8 or 41 8 are open any operation is impossible IP2045EN 2014 09 22 IP2045EN 2014 09 22 6 4 Signals Indicates that at least one of the safety con 92222 Safety test failure terminal 41 tacts is open Activated at every command and adjustment to the dip switch and jumper Indicates that the 0 12 limit switch contact is open 33 7 Radio The control panel is equipped with a radio receiver with a frequency of 433 92 MHz The antenna consists ofa gt D rigid wire 173 mm long Tos connected to the ANT clamp It is possible to increase the range of the radio by a El connecting the antenna of the flashing lights or Receiver by installing the tuned BIXAL antenna NOTE to connect the external antenna to the control panel use a coaxial cable type RG58 max 10 m Check that the storage module is inserted on COM connector of the control panel Up to 200 remote controls can be stored in the storage module WARNING if the radio receiver on the control panel is not used set JR3 OFF and remove the storage module Transmitter storage press the PRG button on the radio receiver or on the control panel the SIG LED lights up make a transmission by pressing one of the desired CH buttons of the transmitter within the range of the radio receiver The transmitter is now stored During this phase the SIG LED flashes When the SIG
4. details of the motorized door When necessary connect the motorized door to a reliable earth system made in accordance with applicable safety regulations During installation maintenance and repair interrupt the power supply before opening the lid to access the electrical parts The protective casing ofthe automation must be removed by qualified personnel only To handle electronic parts wear earthed antistatic conductive bracelets The motor manufacturer declines all responsibility in the event of component parts being fitted that are not compatible with the safe an correct operation For repairs or replacements of products only original spare parts must be used The installer shall provide all information relating to automatic manual and emergency operation of the motorized door and provide the user with operating instructions 11 Installation warning Secure the control panel permanently Drill a hole into the lower side of the container so as to run the cables through it Secure the cables if they are accessible by means of appropriate gland plates not provided by us Keep the line and motor conductors separate at least 8 mm from the control conductors at the terminal board connection points for example by means of clamps Connect the line and motor protection conductors yellow green by means of the transformer and control panel using the clamp provided At the end of the installation to close again the container 26 IP2045E
5. open lamp Q With DIP2 0N the light switches off when the automation is closed QIKLUX Light kit for QIK barrier 24 V 120 mA max With DIP2 0FF the light switches off when the automation is open UWV Motor 1 M1 230V 5A Terminal W must be connected to the common motor phase connec 120 V E1AJ ion The condenser must be connected between the U and V phases Ann Flashing light N TRI LAMP Activated during opening and closing operations 230 V 25 W Q 120 V ETAJ Ti Courtesy light in CROSS sliding automation LUXK7 Comes on for 180 seconds after receiving any opening total or Hon 230 V 60 W partial or closing command a EIT VA WARNING use adubleaustedcable Drive unit external courtesy light Comes on for 180 seconds after 230 V 100 W receiving any opening total or partial or closing command 120 V ETAJ AN WARNING use a double insulated cable Membrane push button panel PT3 Starts the opening operation NOTE to activate the closing operation connect the connector of the push button panel to J12 rotated by 180 J2 Membrane push button panel PT3 Causes the blocking of the movement Membrane push button panel PT3 Starts the closing operation NOTE to activate the opening operation connect the connector of the push button panel to J12 rotated by 180 30 IP2045EN 2014 09 22 IP2045EN 2014 09 22 6 Adjustments 6 1 Trimmer R1 MIN A
6. 14 09 22 IP2045EN 2014 09 22 8 Starting Bridge the NC safety contacts with a jumper Before starting up check the application type selected see JR jumper Any limit switches installed must be adjusted so that they are triggered near the mechanical opening and closing end stops Set TM MAX NOTE limit switches must be kept pressed until the operation has been completed If no limit switches are installed bridge terminals 0 11 and 0 12 with jumpers and set TM to half Set TC MAX Set RF CT 3 and RI to half Using DIP2 set the direction Switch on power LA WARNING The toning operon ae arma p ale doan Perform opening and closing commands and check that the automation functions correctly and that the limit switches if installed are correctly set NOTE if mechanical stops are used to block the stroke of the automation or a proximity limit switch with N O contact adjust the TM trimmer in order to obtain an operation time 2 3 s greaterthan the time effectively taken by the automation Connect the safety devices removing the relative jumpers and check that they function correctly If reguired regulate the automatic closing by means of the TC trimmer Set RF to a position that allows the automation to function correctly while ensuring the safety of the user in the event of collision Set obstacle thrust with R1 NOTE ensure that the forces exerted by the door wings are compliant with EN12453 EN12445 regulation
7. ENTREMATIC Ditec ETA Control panel installation manual for one motor automation with built in radio ETA o o 0 1 c 0 1 1 0 l si i T 1 J12 4 0 1 5 o O PRG F2 JRA JR10 SO 64 JR3 ww QU 1 4 R1 TC TM EER 1 12 F1 12 0 11 aa S ddd POWER SA UWV 1211015 6 8 941 GOL4 UI H O IDOHOOOOjO H 2 4 com at Lamp z Flashing light Stop Safety test Limit switch Limit switch Step by step Power supply Stop safety device Accessories output Safety reopening IP2045EN Technical manual www ditecentrematic com CC 60 7402 N3S70Cdl 24 IP2045EN 2014 09 22 Index EKUM EC declaration of conformity 21 Applications Self controlled safety edge e Adjustments Dip switch Signals NINN Start up La Application example for sliding doors and gates 12 Application example for barriers Application example for sectional overhead doors 25 1 General safety precautions Failure to observe the information in this manual may result in minor personal injury or damage to equipment Save these instructions for future reference This installation manual is intended for qualified personnel only Installation electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with applicable regulatio
8. LED is again lit up itis possible to validate another transmitter Validate all the new transmitters by making a transmission as indicated you automatically exit the procedure 10 seconds after the last transmission or you can press the PRG button again the SIG LED goes off Up to four CH keys of a single remote control can be stored if only one any CH key of the remote control is stored command 1 5 step by step opening is carried out from two to four CH keys of a single remote control are stored the functions matched with the CH keys are as follows e CH1 command 1 5 step by step opening e CH2 partial opening command it causes the automation to open for about 1 m e CH3 command to switch on off the courtesy light e CH4 stop command equivalent to impulsive command 1 9 Transmitter cancellation keep pressed for 3 s the PRG button on the radio receiver or on the control panel the SIG LED begins to flash to erase all the transmitters from the memory of the radio receiver keep pressed for 3 s again the PRG button to erase a single transmitter press one of the previously stored CH keys of the transmitter to be erased the cancellation is confirmed by the quick flashing of the SIG LED If the control panel is replaced the storage module being used can be inserted in the new control panel a mm NT meme mal lariat E Fortuner formaton see he user manust fr GOL series amir 34 IP2045EN 20
9. N 2014 09 22 2 EC Declaration of conformity The manufacturer Entrematic Group AB with headguarters in Lodjursgatan 10 SE 261 44 Landskrona Sweden declares that the control panel Ditec E1A is in conformity with the provisions of the following EC directives EMC Directive 2004 108 CE Low energy Directive 2006 95 CE R8TTE Directive 1999 5 CE Landskrona 29 01 2013 Marco Sala ko 3 Technical data Ditec E1A Ditec E1AJ Power supply 230 V 50 Hz 120 V 60 Hz F6 3A FUSER F8A with NIO OFF iia Fuse F2 if F6 3A Motor output 230 V 5A max 120 V 6 3A max Accessories power supply 24 V 0 5A 24 V 0 5A Temperature 20 C 55 C 20 C 455 C Degree of protection IESS RSS Radio frequency 433 92 MHz 433 92 MHz Memorizable radio codes 200 200 a eee asses se 31 Applications IIUJ in IP2045EN 2014 09 22 27 4 Commands A Command Function Description 1 5 NO STEP BY STEP With DIP1 0FF and TC lt MAX the closure of the contact activates WITH an opening or closing operation in the following sequence open AUTOMATIC stop close open NOTE the stop is not permanent but has the CLOSING duration set by TC STEP BY STEP With DIP1 0FF and TC MAX the closure of the contact activa WITHOUT tes an opening or closing operation in the following sequence AUT
10. OMATIC open stop close open CLOSING OPENING WITH With DIP1 ON and TC lt MAX the closure of the contact activates AUTOMATIC an opening operation CLOSING OPENING With DIP1 ON and TC MAX the closure of the contact activates WITHOUT an opening operation AUTOMATIC If 6 gt 4 0N with the automation idle contact 1 5 performs the CLOSING closure operation as well If 6 gt 4 0FF the closure operation is performed by contact 1 6 1 6 N O CLOSING With 6 gt 4 OF F the closure of the contact activates a closing operation 41 t 6 N C SAFETY STOP The opening of the safety contact stops and prevents any movement 41 t 8 N C REVERSAL SAFETY Opening the safety contact triggers a reversal of the movement DEVICE reopening during a closing operation 1 t__ 9 N C STOP Opening the safety contact stops the current operation EMERGENCY STOP To enable the emergency stop function e g with a specific red button connect the opening and closing controls to terminal 9 instead of 1 9 5 9 6 1 9 N O HOLD TO RUN Permanently opening the safety contact enables the operator FUNCTION presence dependent function In this state the opening 1 5 and closing 1 6 controls function only if held in the pressed position and the automation stops when the controls are released Any safety devices plus the automatic closing are disactivated 0 HE 11 MC CLOSING With DIP2 OFF the opening of the cont
11. PAV E NA 1 t 4 N C STOP SAFETY Connect the output contact of device SOFA1 SOFA2 to DEVICE terminals 1 6 on the control panel in series with the photocell output contact if installed 29 o Output and accessories Output Value Accessories Description TAR Accessories power supply Power supply output for external accessories including automa 01 24 V 0 5A ti ion status lamps The control panel has one space for coupling board type radio receivers magnetic loops etc AUX a a The coupling board working mode is selected by DIP1 WARNING the plug in cards must be inserted and removed with the power supply disconnected Automation open lamp Only with the limit switch 0 11 N C connected and DIP2 OFF will TON 24 Ve 3 W he light switch off when the automation is closed Automation closed lamp amp With DIP2 ON the light switches off when the automation is open AI KLUX Light kit for QIK barrier 24 V 120 mA max With DIP2 ON the light switches off when the automation is open Automation closed lamp Only with the limit switch 0 12 N C connected and DIP2 OFF will 9 4 24 V 3 W he light switch off when the automation is open Automation
12. act blocks the movement LIMIT SWITCH of the automation during the closing phase With DIP2 ON the opening of the contact blocks the movement of the automation during the opening phase Alternatively you can connect the limit switch to the fastons 0 11 in this case the terminals 0 11 must not be jumped 0 11 N O CLOSING In the event of obstacle detection during closing and before the PROXIMITY activation of the proximity limit switch the door wing reopens SWITCH after the activation of the proximity limit switch the door wing blocks against the mechanical closing stop 0 t 12 N C OPENING With DIP2 OFF the opening of the contact blocks the movement LIMIT SWITCH of the automation during the opening phase With DIP2 ON the opening of the contact blocks the movement of the automation during the closing phase Alternatively you can connect the limit switch to the fastons 0 12 in this case the terminals 0 12 must not be jumped 0 12 N O OPENING In the event of obstacle detection before the activation of the PROXIMITY proximity limit switch while opening the door wing stops SWITCH performing a disengagement operation after the activation of the proximity limit switch mechanical opening stop he door wing blocks against the 28 IP2045EN 2014 09 22 IP2045EN 2014 09 22 41 Self controlled safety edge SOFA1 SOFA2 or GOPAVRS Command Function Description TT 2 4 SOFA1 SOFA2 GO
13. ample applications for sliding door and gates When control panel is used for sliding automations ope rations IMI o ox set TM MAX select the proper opening direction by means of DIP2 DIP2 OFF Example 1 Connect opening and closing limit switches N C contacts to plug 12 0 11 fajn MAX 12011 of DIP2 0N Example 2 Connect opening and closing limit switches N C contacts to terminals 0 11 12 With the above connections when limit switches operate the wing stops In the event of obstacle detection the wing stops and releases during opening operation and reo pens during closing operation Limit switch LA Limit switch DIP2 OFF MAX MAX R1 TC TM 12 0 11 DIP2 0N P AA JR6 Haa Li 12110 1 Limit switch Limit switch 37 11 Example of automation in parallel It is possible to command two automations A and B side by side making the connections indicated in figure Commands 1 5 and the remote control with DIP1 ON are equivalent to a total opening command To manage both automations with a single remote contro
14. l do not use the radio receivers on the control panels butinserta BIXLR22 receiver The automatic closing is obtained by regulating the TC trimmer not at the maximum and in the same position in both control panels BIXLR22 JR1 JR2 mM mM mM oL L J GF y EE zf Nie E afz oz ako SC E1A A E1A B E IP2045EN 2014 09 22 IP2045EN 2014 09 22 12 Application example for barriers When control panel is used for barriers operations E i set RF CT 5 MAX set TM MAX set JR6 ON oJ select the proper opening direction by means of DIP2 Example 1 Connect opening and closing limit DIP2 0FF RF CT 5 switches N C contacts to plug 12 0 11 LION ua 12011 DIP2 ON 1211015 6 8 941 Oooo Limit switch Example 2 Control N C 1 6 safety stop can be changed into control N O 1 4 closing setting 6 gt 4 0FF To have the barrier close again soon after transit between the photocells or other safeties con nected to 1 8 set DIP3 OFF
15. means of DIP2 OFF select the closing control by setting 6 gt 4 0FF set SO OFF 40 boh MAX i 12011 Limit switch Limit switch Opening Closing Limit switch Limit switch Opening Closing IP2045EN 2014 09 22 IP2045EN 2014 09 22 All rights related to this material are the exclusive property of Entrematic Group AB Although the contents of this publication have been compiled with the greatest possible care Entrematic Group AB cannot accept liability for any damage that might arise from errors or omissions in this publication We reserve the right to make modifications without prior notice No part of this publication may be copied scanned adapted or modified without prior permission in writing from Entrematic Group AB 41 IP2045EN 2014 09 22 Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www ditecentrematic com ENTREMATIC
16. ns Before installing the product carefully read the instructions Bad installation could be hazard ous e The packaging materials plastic polystyrene etc should not be discarded in the environ CO ment or left within reach of children as these are a potential source of hazard Before installing the product make sure itis in perfect condition Do not install the product in an explosive environment and atmosphere gas or inflammable umes are a serious hazard risk Before installing the motors make all structural changes relating to safety clearances and protection or segregation of all areas where there is risk of being crushed cut or dragged and danger areas in general ake sure the existing structure is up to standard in terms of strength and stability The motor manufacturer is notresponsible for failure to use Good Working Methods in building the frames o be motorized or for any deformation occurring during use A The safety devices photocells safety edges emergency stops etc must be installed taking into account applicable laws and directives Good Working Methods installation premises system operating logic and the forces developed by the motorized door The safety devices must protect any areas where the risk exists of being crushed cut or gragged or where there are any other risks generated by the motorized door Apply hazard area notices required by applicable regulations Each installation must clearly show the identification
17. s Connect any other accessories and check operation Once the start up and check procedures are completed close the container 35 Troubleshooting Automation does not open or close No power Check that the control panel is POWER led off powered correctly Blown line fuse POWER led off Replace fuse Safety contacts not correctly con Check connections to terminals 6 8 nected or self controlled safety on control panel and connections edge SOFA1 SOFA2 not functioning to the self controlled safety edge External safety devices not activat ing correctly SA led flashing The motor thermal overload switch is open The remote control does not work SIG led flashing Safety contacts not correctly con nected or self controlled safety edge SOFA1 SOFA2 not functioning correctly SA led flashing The automatic closing does not work Incorrect connections between the photocells and the control panel 36 SOFA1 SOFA2 Check for continuity between the phases U V W of the motor discon nected from the control panel Memory module BIXMR2 absent Check connections to terminals 6 8 on control panel and connections to the self controlled safety edge SOFA1 SOFA2 Check that the TC trimmer is not set at the maximum Connect NC safety devices together in series and remove any bridges on the control panel terminal board IP2045EN 2014 09 22 IP2045EN 2014 09 22 10 Ex