1. FLUKE networks FI 7000 FiberInspector Pro Video Probe Getting Started Guide The FI 7000 FiberlInspector video probe lets you see dirt scratches and other defects that can cause unsatisfactory performance or failures in fiber optic networks a Accessing the Product Manuals This guide provides basic information to help you get started using the tester For more detailed information see the latest versions of the Versiv Users Manual and the Versiv Technical Reference Handbook provided on the Product Manuals DVD and on the Fluke Networks website ia Information Warning or Caution Risk of damage or destruction to equipment or software See explanations in the manuals A Waring Risk of fire electric shock or Pema eerie cect tocar eon injury Fiala al EEE This key turns the Product on and off Z Warning To prevent possible fire electric shock or personal injury e Read all safety information before you use the Product e Carefully read all instructions e Do not open the case You cannot repair or replace parts in the case e Do not modify the Product e Use only replacement parts that are approved by Fluke Networks e Do not touch voltages gt 30 V AC rms 42 V AC peak or 60 V AC e Do not use the Product around explosive gas vapor or in damp or wet environments PN 4467086 4 2014 2014 Fluke Corporation All product names are trademarks of their respective companies Use this Product indoo
2. Fl 7000 kit Keep the module installed to give protection to the module connectors Micro AB USB port This USB port lets you connect the tester to a PC so you can upload test results to the PC and install software updates in the tester Type A USB port This USB host port lets you connect the FI 7000 probe to the tester or save test results on a USB flash drive QDOAOQOOOE GPU173 EPS Figure 1 Connectors Keys and LEDs Headset jack vtest Starts a test To start a test you can also tap TEST on the display Power key Home Press to go to the home screen Connector for the ac adapter RJ45 connector for functions available in future software releases Removable tip for different types of connectors Dial for focus adjustment How to Do a Fiberlnspector Test 1 Power the Tester Charge the battery if necessary Connect the ac adapter to ac power and to the adapter connector 9 shown in Figure 1 You can use the tester while the battery charges 2 Connect the FI 1000 Probe With the tester off connect the probe to the type A USB port on the side of the tester Then turn on the tester Figure 2 shows the home screen for a Fiberlnspector test 3 Install the Correct Tip on the Probe See Figures 3 and 4 16 03 2014 11 14 17 am 504 7X 4 Py alie FI 7000 a cr ID ot PROJECT TOWNCENTER BANK RESULTS 103 EPS To set up a proj
3. OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages this limitation of liability may not apply to you Fluke Networks PO Box 777 Everett WA 98206 0777 USA 4 04
4. ect tap the PROJECT panel To change settings for the test tap the test setup panel To set up cable IDs turn on Auto Save and change the settings for the fiber End tap the Next ID panel To enter the operator name tap the Operator panel Figure 2 Panels on the Home Screen GPU168 EPS Turn the dial to move the view of the endface GPU175 EPS Figure 4 How to Use the Optional MPO MTP Inspection Tip Clean the Connector Use proper cleaning procedures to clean the connector you will inspect Do the Fiberlnspector Test Tap Test or press vTest To adjust the focus turn the dial on the probe 6 Examine the Results See Figure 5 1 Manual limit selected default To give a PASS or FAIL grade to the image tap GRADE 2 Test limit selected To see an analysis of the defects tap ANALYZE The tester uses the selected test limit to give scratches and defects a PASS green highlight or FAIL red highlight grade Z Caution If a defect is possibly a dirt particle clean the endface and do the inspection again You must remove all loose particles because they can move into the core when you make connections GRADE NEXT SCALE SCALE OFF Figure 5 Examples of Fiberlnspector Results Screens 102 EPS Save the Results 7 1 Tap SAVE 7 2 If the Cable ID box shows the correct ID tap SAVE To enter a cable ID tap the Cable ID box on the SAVE RESULT screen use the keyboard
5. for Korea Class A Equipment Industrial Broadcasting amp Communication Equipment This product meets requirements for industrial Class A electromagnetic wave equipment and the seller or user should take notice of it This equipment is intended for use in business environments and is not to be used in homes ASIII 228 H SSA0 AM WWE SSS As ANUS SBIVISA DOA SE ASME Ol SS FAHI bret S22 ASAA ASote AS SALTS hers LIMITED WARRANTY AND LIMITATION OF LIABILITY Fluke Networks mainframe products will be free from defects in material and workmanship for one year from the date of purchase Parts accessories product repairs and services are warranted for 90 days unless otherwise stated Ni Cad Ni MH and Li lon batteries cables or other peripherals are all considered parts or accessories This warranty does not cover damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke Networks behalf To obtain service during the warranty period contact your nearest Fluke Networks authorized service center to obtain return authorization information then send your defective product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE NETWORKS IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL
6. rs only Use the Product only as specified or the protection supplied by the Product can be compromised Do not use and disable the Product if it is damaged Do not use the Product if it operates incorrectly Batteries contain hazardous chemicals that can cause burns or explode If exposure to chemicals occurs clean with water and get medical aid Remove the batteries if the Product is not used for an extended period of time or if stored in temperatures above 50 C If the batteries are not removed battery leakage can damage the Product The battery door must be closed and locked before you operate the Product Repair the Product before use if the battery leaks Recharge the batteries when the low battery indicator shows to prevent incorrect measurements Do not disassemble or crush battery cells and battery packs Do not put battery cells and battery packs near heat or fire Do not put in sunlight Have an approved technician repair the Product For Products with rechargeable batteries use only AC adapters approved by Fluke Networks for use with the Product to supply power to the Product and charge the battery A Caution To prevent damage to the Product or cables under test and to prevent data loss read all safety information given in all documentation supplied with the Product Connectors Keys and LEDs See Figure 1 Q N LCD display with touchscreen Blank module included with the
7. to enter a name for the results tap DONE then tap SAVE The tester saves the results in the DEFAULT project unless you selected a different project About Projects You can set up a project to specify the settings and tests necessary for a job monitor the status of a job and organize the test results To start a new project tap PROJECT on the home screen tap CHANGE PROJECT then tap NEW PROJECT See the Users Manual or Technical Reference Handbook on the DVD for more information Registration Registering your product with Fluke Networks gives you access to valuable information on product updates troubleshooting tips and other support services To register use LinkWare software Contact Fluke Networks i www flukenetworks com z4 support flukenetworks com 1 800 283 5853 1 425 446 5500 Fluke Networks operates in more than 50 countries worldwide For more contact information go to our website General Specifications Temperature Operating 18 C to 45 C Storage 30 C to 60 C Altitude Operating 4 000 m 3 200 m with AC adapter Storage 12 000 m Certifications and Compliance C Conformite Europeene Conforms to the requirements of the European Union and the European Free Trade Association EFTA Ge Listed by the Canadian Standards Association C US Conforms to relevant Australian standards N10140 Pe Conforms to relevant Russian standards C KCC REM FKN 012001001 EMC approval