Home

7846 Manual

image

Contents

1. greatly reducing their holding power e Make sure that mounting screws are anchored into the center of the stud The use of an edge to edge stud finder is highly recommended e Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs Installers are responsible for providing hardware for other types of mounting situations Using a stud finder locate and mark the edges of the wood stud Use of an edge to edge stud finder is highly O recommended Use a level to draw a vertical line down the center of the stud Use the wall plate of the mount AA as a template to mark the center of holes along the vertical line The top mounting holes should be 5 above the desired screen center as shown in figure A 1 Drill three 3 16 5 mm dia pilot holes 2 76 mm deep Attach the mount AA to wall using three M6 X 60 cross slotted head screw G as shown in fig A 2 Level the plate then tighten all fasteners CS center of screen fig A 1 STUD l 5 ec mm STUD fig A 2 4of 8 Installation to Solid Concrete or Cinder Block e When installing the wall mount to cinder block verify that you have a minimum of 1 3 8 of actual solid concrete thickness in the hole to be used for the concrete anchors Do not drill into mortar joints Be sure to mount in a solid part of the block generally 1 minimum from the s
2. sure concrete anchors do not pull away from concrete when tighten ing screws If plaster drywall is thicker than 5 8 custom fasteners must be supplied by the installer INCORRECT concrete A ia CORRECT wall plate pa L ey concrete i Pe E Pinel A piasier o 0 iz drywall 4 i drywall gt CUTAWAY VIEW Attaching display mounting plate AA to a Screen with a VESA Mounting Pattern Choose hole pattern as shown in detail 3 for VESA mounting pattern Begin with the shortest length screw hand thread Occ adapter plate into screen as shown in detail 4 Screw must make at least three full turns into the mounting hole and fit snug into place Do not over tighten If screw cannot make three full turns into the screen select a longer length screw from the fastener pack Repeat for remaining mounting holes Securely tighten screws NOTE Spacers do not have to be used depending upon the type of screen 0 I VESA 400 x 200 DETAIL3 NOTE For screens with a hole ADAPTER pattern in a pocket pole spacers go between adapter plate and screen 6 of 8 ca For Flat Back Screen For Beveled Back Screen Select the small medium large or extra large screws from the baffled fastener pack then attach screen brac
3. MONOPRICE INSTALLATION GUIDE Flat Panel Arm Mount MDA 46 Support 32 to 46 Screens Max Load Capacity 125 Ibs 57 kg VESA 400x400 compatible Be sure to read this entire manual thoroughly and you fully understand all the instructions and warning before attempting to begin your installation This product should only be installed by someone who has a basic knowledge of buiding construction installations and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the mount the display and all attached hardware and components This wall bracket will only supporting flat panel displays LCD Plasma The maximum load capacity is 125 pounds If mounting to a wall of wood stud construction be sure that mounting bolt are anchored to the center of the studs Always have someone assist you to lift and position your equipment Tighten screws and bolts firmly but do not over tighten Over tightening can damage the items and greatly reduce their ability to hold Please refer to suggested torque values where applicable in these instructions Tools Needed for Assembly e stud finder edge to edge stud finder is recommended e phillips screwdriver e pencil e drill e 3 16 drill bit for wood studs 5 16 drill bit for concrete e level e tape measure Table of Contents Fe a NS EEE E P A EE aus aeccdeinececoede nam
4. es acces T A cca E N A A E E E EE 3 IS tallatiom to Single Wood Swa Wall raster sisectetcnctterectercnadnenadeaesintcuee e aa e EA a Eaa a i ea adaa i 4 Installation to Solid Concrete and Cinder Block sicidcinsnncvsdecisetemavesdiaxsnaessocncan vaaiuaaudaaeseasuewoducoaumeneyanadaumessbunvecdacaseidsedauaracayaaces 5 Attaching the mount to Screens with VESA Mounting Patterns cccccc ccc ecceeeceeceeeceeeeeeceeeseeceeeceeeeeeseeseeeseeeeeseeeges 6 7 cable NAVA SU ae crete acetate tres eee sacs aston eee ek aeesat ea re sees deo meee act E eaten saandy E avudeevenvenseeues mien 8 2 of 8 Before you begin make sure all parts shown are included with your product Parts may appear slightly different than illustrated Parts List OS a M6x16 x4 M6x30 x4 M8x16 x4 M8x35 x4 Z 19x8 2x Z 19 6 x4 philips pan head screw philips pan head screw philips pan head screw philips pan head screw Spacer D AA CO SSW C 12 7x6 0x C 12 7 x4 M6x60 x3 M6x40 x3 spacer cross slotted head screw concrete anchor F G H E M6x8 x8 Z6 2x1 5x C 13 x8 BB X4 3 of 8 Installation to Single Wood Stud Wall A WARNING e Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components e Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws
5. h iy ri all fig E1 Q Cable Management Note Make sure cords have enough slack to allow full movement of the arm Route cords inside arm slots of wall arm assembly AA as shown in fig F 1 For demonstration purposes the wall has been omitted from the image Cord Cover A WARNING e Do not remove or loosen screw while the mount is in use Doing so may cause the screen to fall 8 of 8
6. ide of the block Cinder block must meet ASTM C 90 specifications It is recommended that a standard electric drill set on a slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity e Concrete must have a 2000 psi density minimum Lighter density concrete may not hold the concrete anchor e Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard ware and components concrete Use wall plate AA as template to mark mounting holes The top mounting hole should be 5 above the desired screen center as shown in figure A 1 on page 4 Drill three 5 16 8 mm dia holes 2 50 mm deep as shown in fig B 1 Insert concrete anchor H in holes flush with the wall as shown right Place wall plate over anchors and secure with M6x 60 screws G Level then tighten all fasteners surface e Tighten screws so that wall plate is firmly attached but do not overtighten Overtightening can damage screws greatly reducing their holding power ALZZZZIN ZZ A Tighten all fasteners Always attach concrete anchors directly to load bearing concrete Never attach concrete anchors to concrete covered with plaster drywall or other finishing material If mounting to concrete surfaces covered with a finishing surface is unavoidable the finishing surface must be counterbored as shown below Be
7. kets AA to screen following figure C 1 1 or C 1 2 on page 7 Insert two for 200x200 amp 200x100 VESA patterns appro priate sized bolts C into the top two mounting holes on the back of your display as shown in fig C 2 1Leave approx 1 4 of exposed thread Lift the display and hook it on to the display mount ing plate by lowering the exposed portion of the top screws down the notches on the top edge of the plate for a 200x200 pattern or into the key hole Once in position attach the bottom two for a 200x200 pattern bolts C to secure the display to the mounting plate as shown in fig C 2 2 A WARNING e Do not lift more weight than you can handle Use additional man power or mechanical lifting equipment to safely handle placement of the screen CAUTION e Do not tighten screws with excessive force Overtightening can cause damage to mount 7 of 8 E 1 to desired tension to balance your screen size knob and weight The tension knob without changing the bracket tension D can be pulled out away from the bracket and turned independently of the knob post for readjustment as NTa abs shown in fig E 2 L Push or pull from top or bottom of screen to adjust i tilt as shown The tilt can be adjusted to a maximum of 5 forward or 15 backward E Adjust tension knob on side of mount as shown infig ndbr e Be careful not to pinch fingers when opening and closing mount from the wall A

Download Pdf Manuals

image

Related Search

Related Contents

Installation manual VZ-C12 und VZ-C32 Englisch und  manualde instrucciones • manual de instruções  Samsung Four compact pose libre 36L CQV137-S Manuel de l'utilisateur  Istruzioni d`uso WEIGHTRAC 31  EN FAN COIL uNIts Installation instructions FR VENTILO  966 AMPLITUDE  Operación del sistema. (PDF - 579.32 KB)  穨 66M-K800-002(A)  Minka Lavery 1298-648 Instructions / Assembly  Tokina AT-X 116 Pro DX II  

Copyright © All rights reserved.
Failed to retrieve file