Home
User manual
Contents
1. The firmware type written in the module header of the firmware must be compatible to the hardware and allowed firmware type stored inside the Bootloader Starting includes a hardware reset of the TA Note If new functionality has been added your last stored configuration may be lost If the flash memory size is only 4Mbit this command is not supported 74 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set htc highest 2 way channel X 25 B channel Highest switched virtual logical channel for incoming and outgoing X 25 connections htc 1 4095 default 1 The value range for this LCN logical channel number can be set from 1 to 16 LCN bit 1 to bit 4 LCN values from 17 to 256 LCN bit 5 to 8 are currently not supported These LCN values will fail within the outgoing call with the result code NO DIALTONE Explanation of X 25 channel number structure Logical channel group number Logical channel number LCGN 4 bit length bit 9 to 12 LCN 8 bit length bit 1 to 8 XX XX 0000 XX XX Example LCGN 0 and LCN 1 htc value 0x001 1 LCGN 0 and LCN 5 htc value 0x005 5 LCGN 2 and LCN 10 htc value 0x20A 522 LCGN 4 and LCN 1 htc value 0x401 1025 LCGN 15 and LCN 1 htc value OxF01 3841 idle Idle data timeout Timer to disconnect the ISDN B channel connection after inacti
2. 12 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 17 Delete Line Defines the Line Delete character thus the ASCII value of the character with which you can delete the previous line Only possible if parameter 15 is set to 1 PAD has editor capability Valid Parameter Values n nis an integer in the range from 1 to 255 and gives the ASCII value decimal of the desired Line Delete character default 127 gt lt Delete gt key 18 Repeat Line Defines the Line Display character thus the ASCII value of the character with which you can cause the characters that were entered on the previous line to be repeated on the current line Only possible if parameter 15 is set to 1 PAD has editor capability Valid Parameter Values n nis an integer in the range from 1 to 255 and gives the ASCII value decimal of the desired Line Display character default 0 19 Handling Delete Characters Defines what should be sent to the screen when a Character Delete or a Line Delete character is received Valid Parameter Values 0 Nothing 2 Send a lt BS gt lt Space gt lt BS gt so that the last character displayed is deleted Stollmann Entwicklungs und Vertriebs GmbH 13 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 19 Echo Filter If parameter 2 is set to 1 character echo during data transfer
3. 56 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 3 7 3 3 Successful outgoing call and disconnect AT application TA HIT module Remarks AT CR D234 0567 Initiatate outgoing call to 234 CRAI1B01 Request accepted use call reference 1 B channel B01 RINGINGI1 Destination is ringing SCONNECTI1D2340567B01 Connection established DISCI11C3490 Connection released normal clearing AT REL 11 gt Disconnect release call reference SOK OK NOTE In case of receiving RELI1C3490 in case of DISCI1C32490 no additional AT REL 11 command is required Stollmann Entwicklungs und Vertriebs GmbH 57 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 3 8 ISDN leased line option With a special firmware generation the TA POX TA HUX TA SOC supports the connectivity of an ISDN leased line type 64S or 6482 To use the TA POX on an ISDN leased line you have to configure the firmware especially This chapter includes the special settings for the leased line configuration only The following parameter must be set ISDN Select D channel protocol Selects ISDN D channel protocol to the ISDN line The protocol must fit the protocol running on the ISDN line otherwise a connection cannot be set up Note after changing and storing the ISDN protocol the TA has to be reset by pow
4. S7 set the length of time in seconds the TA will wait for carrier before hanging up The timer is started when the dial command line was closed by the Carriage Return character and stopped when the data channel protocol ATBn was synchronized The default value is set to 30 seconds s9 WINDOWS PrP functionality S9 controls the functionality to react to the WINDOWS specific Plug and Play feature ATS9 0 disable PNP feature default ATS9 1 enable PNP feature Note See also internal configuration command PNP Stollmann Entwicklungs und Vertriebs GmbH 33 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 12 Escape Sequence delay time 12 controls the delay time in 10ms steps before and after the Escape Character configured in the parameter ATS2 to switch from the online data mode to the online command mode The default value is set to 100 which equals 1 second Example for the default escape sequence lt delay time 1 sec gt lt escape sequence gt lt delay time 1 sec gt S16 Last occurred CAPI ISDN cause 16 reports the last occurred internal CAPI cause or ISDN error cause This parameter is read only is will not be saved in the stored configuration profile ATS16 Reports the last occurred CAPI ISDN error cause S20 Command Line timeout S20 controls the timeout for the current command line if no Carriage Return character ATS3 end of l
5. gt save the new configuration e Leave your terminal emulation and start your application program With the exception of the command A Repeat command all commands begin with the prefix AT and are terminated with lt gt Corrections in a command line are done with lt BACKSPACE gt A command line has a maximum of 80 characters up to 140 characters using UUS1 The command line is automatically cancelled by longer input Blanks are ignored capital small letters are not significant The parameter settings of the TA POX obtained when using the AT commands can be permanently stored AT amp W and are not lost by resetting or by leaving the AT command mode Stollmann Entwicklungs und Vertriebs GmbH 17 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX To enter the AT command mode during an active data connection you must use the following sequence Escape sequence 1 lt delay time according to S12 register gt 2 lt gt lt gt lt gt 3 lt delay time according to S12 register gt The time gap between all three plus signs may not exceed 1 sec The escape sequence is transmitted transparent to the remote device Note If B channel protocol PPPasync ATB3 is selected the escape sequence has to be included in an asynchronous HDLC frame The coding of the complete asynchronous sequence is 7E 2B 2B 2B 1B B4 7E The timeout after sending the escape sequence lt gt lt gt lt g
6. Call collision 49 X X 25 repeated facility request X 75 missing transit DNIC 4A X Non zero address length 4B X Non zero facility length 4C X Facility not provided when expected 4D X Invalid ITU specified DTE facility 4E X max number of call redirections or call deflections exceeded 51 X X X Improper cause code from DTE 52 s4 X X Not aligned octet 53 X Inconsistent Q bit setting 54 X 7 NUI problem 61 X DNIC not accessible 62 X Unknown transition DNIC 64 X 75 Wrong use of facility 65 X Erroneous length of Net Indicator 66 X Length of Net Indicator not equal zero 67 X Erroneous M Bit 71 X X Problem concerning remote net 72 X X International net problem 73 X PVC Transmission section out of operation 74 X PVC International line engaged 75 X PVC Error in the transit net 76 X Error in the destination net invalid facility found 77 X International routing problem 78 X Temporary routing problem 79 X Unknown called DNIC 7A X X Service 80 X Erroneous Q Bit or 8 X X No operation means available 81 X Single packet not agreed upon or 81 X X Temporarily out of operation 82 xX X X Cause flied not equal 00 hex or 82 X X Closed by service provider e g DATEX P 83 X PVC Incompatible packet length 84 X Erroneous M Bit Stollmann Entwicklungs und Vertriebs GmbH 95 TA HIX TA
7. Note This message is repeated like in AT modems The repetition time is configured in parameter ATS80 time in 100ms steps The default value is set to 50 which is 5 seconds RINGING I lt Call Reference gt called party is ringing Indicates that the call request is accepted at the called party and a ringing is issued Example RINGINGI1 Note This message is not repeated like in AT modems Stollmann Entwicklungs und Vertriebs GmbH 55 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 3 7 3 IOM 2 connection control examples 3 7 3 1 Accepted incoming call AT application TA HUX module Remarks RINGI1D2340567B01 Incoming call call reference is valid AT Al1 gt Accept the call SCONNECTI1D2340567B01 Connection established AT DISC I1 C3400 gt Disconnect normal clearing release call reference SOK Disconnected RELI1C used B channel is free 3 7 3 2 Rejected incoming call AT application TA HIT module Remarks C RINGI1D2340567B01 Incoming call call reference is valid AT DISCI1C3491 gt Disconnect cause user busy release call reference SOK Disconnected RELI1C used B channel is free NOTE If the disconnect command AT DISCIxC3491 will not receive the requested respone RELIxC3490 within about 1 second the additional AT RELIx command is required to clear the current used ISDN B channel immediately
8. Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 Table of Contents LED displays TAP OK scot troreeict ant deterrent eth eter ebetteniedeeieeeerebentibeess 107 TA HUX V1 Mechanical dimensions of the module V1 ccceeeeees 108 TA HUX V1 Serial Interface Connector P1 ccccccccceccececeeeeeeeeeeeetees 109 TA HUX V1 ISDN interface Connector P2 cccccccccccccececeeeeeeeeeeeeeeees 110 TA HUX V1 IOM Interface Connector P3 cccccccccececcccceeeeeeeeeeeeeeeeeess 110 TA SOC V2 Mechanical dimensions of the module cccccceseeeeees 111 TA SOC V2 connector X1 1O2X Gv ces vans cheschessantevessvedekpssaesezpsebetekataanaczaeoese 112 TA POX Pinout of the ISDN connector ccccccceccccceeeeceeeeeeeeeeeeeeeees 113 TA POX Pinout of the V 24 V 28 interface DSUB 9 eee 113 TA POX Cable layout for connection of terminals with 25 pin connectors Male OF TEMAIG si ccestticteic a E E EA li edel ERR 114 TA POX Cable layout to connect a PC with 9 pin male plug through a serial ION jae eh Neale he ahha i nN Se ee el tec ih ee Se ca et 115 Stollmann Entwicklungs und Vertriebs GmbH iii r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 1 Introduction 1 Introduction We are very pleased to see that you have bought a Stollmann product and would like to expres
9. flc CTS signals the serial flow control from TA DCE to the DTE in the flow control modes 3 or 5 flc 3 or flc 5 40 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX DTR Data terminal ready The serial status line DTR is used to control the ISDN connection 0 No control Outgoing calls The DTR level will be ignored to establish a connection Incoming calls Incoming calls will be accepted independent of DTR status Disconnection DTR drop does not disconnect an active connection 2 DTR line will be considered Outgoing calls The DTR level will be considered DTR off in the command mode refuses the call procedure with ERROR Incoming calls Incoming calls will be accepted only when DTR is ON The incoming call request can be refused with changing DTR to off Disconnection DTR drop disconnects an active connection or a call during the dial phase If DTR will be dropped immediately after sending serial data there is no guarantee to transmit these data to the destination side A delay of configured txfwd time 10ms between sending the last data byte and dropping the DTR line would send out the last data stream 4 DTR ignore and DTR drop disconnects Outgoing calls The DTR level will be ignored to establish a connection Incoming calls Incoming calls will be accepted independent of DTR status Disconnection DTR drop disconnects an active
10. 0xC1 Stollmann Entwicklungs und Vertriebs GmbH 91 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 5 Diagnostic and error messages Cause Meaning Translation Translation Decimal to AT to X 25 Hexadecimal result cause codes diagnostic 66 OxC2 Channel type not implemented 13 78 69 OxC5 Requested facility not implemented 13 78 capability is available Gili Sulla unspecified 81 0xD1 Invalid call reference value 82 OxD2 Identified channel does not exist 83 0xD3 A suspended call exists but this call 1 78 identity does not 84 0xD4 Call identity in use 85 0xD5 No call suspended 86 0xD6 Call having the requested call identity has been cleared Invalid transit network selection 95 OxDF Invalid message unspecified 96 OxEO Mandatory information element missing Message type non existent or not implemented 98 OxE2 Message not compatible with call state 3 or message type non existent or not implemented Information element parameter non existent or not implemented 101 0xE5 Message not compatible with call state 102 0xE6 Recovery on timer exopir Parameter non existent or not implemented passed on N N N N 1 78 1 78 1 78 i N 1 78 PININ l l NIDN J 1 78 NINNIN _ N oc N N 00 N 92 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual
11. 5 Diagnostic and error messages 5 4 X 25 causes and their explanation 5 4 1 X 25 causes in Clear packet Coding of the field cause in packet Indicate Cause 00 DTE CONF Triggered by the remote DTE DCE 01 OCC Remote DCE busy dialed number busy engaged 03 INV Facility requested not valid supported 05 NC Temporary disturbance in network 09 DER Remote DTE doesn t answer out of operation OB NA Access not available OD NP No access with this dial number 11 RPE Remote procedural error sequence error 13 ERR Local procedural error sequence error 19 RNA Reverse charging not accepted 21 ID Remote DTE DCE incompatible 29 FNA Incompatible connection request receipt of single packet not agreed upon Stollmann Entwicklungs und Vertriebs GmbH 93 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 5 Diagnostic and error messages 5 4 2 X 25 diagnostic codes No hex Restartind Resetind Meaning Clearind Diagnostic 00 X X X No additional information 01 7 X Invalid P S 02 X Invalid P R 10 X Packet type invalid 11 X PVC X Packet type invalid for state r1 12 X PVC X Packet type invalid for state r2 13 Packet type invalid for state r3 14 X Packet type invalid for state p1 15 X Packet type invalid for state p2 16 X Packet type invalid for state p3 17 X Packet type invalid for state p4 18 X Packet type invalid for state p5 19 X Packet type
12. 701 you have to set br to fixed speed defa default settings Sets up factory default parameter setting defa 0 setup all parameter concerning data port defa 1 setup all parameter including ISDN protocol and msn settings dhtc highest 2 way channel X 25 D channel Highest switched virtual logical channel for incoming and outgoing X 25 connections dhtc 1 4095 default 1 The value range for this LCN logical channel number can be set from 1 to 16 LCN bit 1 to bit 4 LCN values from 17 to 256 LCN bit 5 to 8 are currently not supported These LCN values will fail within the outgoing call with the result code NO DIALTONE Explanation of X 25 channel number structure Logical channel group number Logical channel number LCGN 4 bit length bit 9 to 12 LCN 8 bit length bit 1 to 8 XX XX 0000 XX XX Example LCGN 0 and LCN 1 dhtc value 0x001 1 LCGN 0 and LCN 5 dhtc value 0x005 5 LCGN 2 and LCN 10 dhtc value Ox20A 522 LCGN 4 and LCN 1 dhtc value 0x401 1025 LCGN 15 and LCN 1 dhtc value OxF01 3841 72 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set ditc lowest 2 way channel X 25 D channel Lowest switched virtual logical channel for incoming and outgoing X 25 connections ditc 1 4095 default 1 The value range for this LCN logical channel numbe
13. G lt cug gt H lt own X 25 numbers gt lt X25number gt D lt userdata gt lt cr gt CALLEDnumber SDN call number for a dialed B channel connection or X 25 number for X 31 D channel X starting X 25 parameter section P use packet size xxx for X 25 connection value from 64 2048 The separator after Pxxx will allow or request the facility reverse charging access to X 25 closed user group Outgoing call from X 25 closed user group use NUI and password with call setup allowed chars a z A Z 0 9 set own X 25 number for outgoing calls max length 15 digits overwrites setting of XNR configuration command in chapter 4 4 2007 Stollmann Entwicklungs und Vertriebs GmbH 21 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX NOTE For X 31 D channel calls the configured own X 25 address will be compared with the real X 25 address of the local X 25 access point In case of different X 25 numbers the X 25 packet handler will use its own configured X 25 number X25number dialed X 25 call number X 25 B channel only max length 15 digits D separator for user data D user data without protocol ID data length max 16 char P user data with protocol ID 01000000 data length max 12 char ATD lt CALLEDnumberse Make a call for remote management see note Adding an e to CALLEDnumber indicates that a connection to the internal remote access of a TA shall be p
14. Physical dimensions TA POX TA HUX TA SOC Power supply TA POX TA HUX TA SOC 106 V 24 V 28 9 pin DSUB connector female V 24 TTL double pin rows P1 V 24 TTL single pin rows X4 1200 230400 bit s asynchronous 2 x 64000 bit s synchronous 8Bit no Parity 1 stop bit 7Bit even odd Parity 1 stop bit asynchronous half duplex or full duplex S bus interface according to ITU 1 430 build in RJ45 plug double pin rows P2 single pin rows X3 desktop casing 71 x 22x 123 mm WxHxD plug on module 56 x 56x 12 8 mm WxHxD plug on module 64 5 x 26 5 x 14mm WxHxD external power supply 5V DC 5V DC 3 3V DC 5 via double pin row P2 3 3V DC 5 via single pin row X5 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 6 Appendix A2 LED displays TA POX Active states L1 L2 Status amp amp Power On Phase Wait 0 5 s amp Firmware start up wait 2 sec ixis O ISDN not ok Check ISDN interface connector amp O Active phase ISDN ok no ISDN connection established amp Call active ISDN Connection will be established amp Synch active Waiting for B channel synchronization amp amp Connected Data connection is established B1 B2 Status B channels O B channel offline amp B channel online ISDN connection established Error states L1 L2 Status O O TA POX not ok Hardware error TA POX
15. Using the TA POX exec lt cmd gt Executes one TA configuration command for definition of commands see page 66 Example exec msni 12345 set specific msn value for incoming calls 3 1 1 X 3 Parameter of the integrated PAD Using the PAD command set x n you can change the parameter according to ITU specification X 3 After changing one or more X 3 parameter you can store the change non volatile by issuing exec save The stored parameter can be reloaded with the command exec load After an X 25 connection is cleared the PAD parameter will be reset to the last active profile or default International Parameters 1 through 12 1 Enable disable switch to command mode Defines whether the terminal user may switch from data to command mode e g to change a X 3 parameter and if he may which key s must be pressed to make the switch Valid Parameter Values 0 Switch to command mode disabled 1 Switch to command mode enabled switch by pressing the key combination lt CTRL gt P hexadecimal 10 decimal 16 n Switch to command mode enabled switch by entering the ASCII character that corresponds to the parameter value n decimal integer value in the range between 32 and 126 2 Echo Determines whether a character will be echoed to the terminal data transfer mode Valid Parameter Values 0 No echo 1 Echo 8 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX
16. protocol ID DTR control Selects the behavior of the TA when the DTE control line DTR changes from ON to amp D OFF AT amp D AT amp D2 AT amp D4 DTE control line DTR setting is ignored DTE control line DTR is evaluated dropping the DTR line by the DTE will disconnect an existing ISDN connection default An incoming call will accepted only with DTR active DTE control line DTR is evaluated dropping the DTR line by the DTE will disconnect an existing ISDN connection An incoming call will accepted with DTR off For nearer information see also chapter 3 3 E Local echo Selects the local echo in command mode ATE ATE1 No local echo Local echo on in command phase default Stollmann Entwicklungs und Vertriebs GmbH 23 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX amp F Load factory defaults Factory default will be loaded ISDN protocol settings passwords and msn s will not be overwritten for storing in non volatile memory please use the command AT amp W AT amp F setup all parameter concerning data port AT amp F1 setup all parameter including ISDN protocols msn settings and passwords H Disconnect Disconnects existing ISDN data connection after issuing the escape sequence see page 17 ATH To enter the AT command mode during an active data connection you must use the following sequence Escape sequence 1 lt delay time accordi
17. this parameter can be used to determine which characters entered from the keyboard will not be echoed to the screen Valid Parameter Values 128 No echo filter thus echo all characters No echo for lt CR gt No echo for lt LF gt No echo for lt VT gt lt HT gt lt FF gt No echo for lt BEL gt lt BS gt No echo for lt ESC gt lt ENQ gt No echo for lt ACK gt lt NAK gt lt STX gt lt SOH gt lt EOT gt lt ETB gt lt ETX gt No echo for editing characters those set with the parameters 118 119 and 120 No echo for lt DEL gt or any other ASCII control character not listed above Note This parameter is interpreted bit wise thus any combination of the above listed values can be combined to form a sum of the desired values 21 Parity handling Read only Handles and displays used parity on asynchronous line 14 0 no parity 1 odd parity 2 even parity 3 no parity Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX National Parameters 118 126 118 Character Delete Character See parameter 16 119 Delete Line See parameter 17 120 Repeat Line Line Display Character See parameter 18 123 Parity handling See parameter 21 126 Generating a Line Feed See parameter 13 Note The following parameter values are not implemented 5 10 22 121 122 125 Note Th
18. CTS control CTS control 0 CTS follows RTS 1 HW FLC hardware flow control RTS CTS default 2 CTS follows DTR For nearer information see also chapter 3 3 Stollmann Entwicklungs und Vertriebs GmbH 69 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set cdcd DCD control DCD control 0 DCD always ON 1 DCD indicates a connection default 2 DCD follows DTR For nearer information see also chapter 3 3 cdsr DSR control DSR control 0 DSR always ON 1 DSR indicates a connection 2 DSR follows DTR 3 DSR follows DCD 5 DSR Off Hook default For nearer information see also chapter 3 3 cdtr DTR control Usage of DTR to control ISDN connection 0 No control Incoming calls will be accepted independent of DTR status DTR drop does not disconnect an active connection 2 DTR off disconnects default Incoming calls will be accepted only when DTR is ON DTR drop disconnects an active connection 4 DTR ignore and DTR drop disconnects Incoming calls will be accepted independent of DTR status DTR drop disconnects an active connection For nearer information see also chapter 3 3 70 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set chappwd set password for PPP chap authorization only required for WINDOWS 95 Enable ML PPP CHAP authorization by setting the passwo
19. EN50081 1 here EN55022 Class B for electromagnetic field emission and EN50082 1 for immunity against electromagnetic interference 2 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 2 2 Installation Installation 2 1 Contents This packet contains the following items ISDN Terminal adapter TA POX in desktop box Mains plug power supply adapter only TA POX ISDN interface cable only TA POX DTE interface serial cable only TA POX This user manual 2 2 Installation procedure Connect the serial port DTE of the TA POX to the serial port COM port of the PC by using the supported DTE interface serial cable Please make sure that the COM port of the PC is not used for other purposes or by other communication programs Connect the ISDN port of the TA POX to the basic rate interface BRI of the ISDN using the delivered ISDN cable Connect the power supply with the TA POX and plug it into mains Please reference to page 5 for selecting the correct plug for interfacing Now the power up sequence described in chapter 2 3 should appear The TA POX is now ready for use please refer to the next chapter for the configuration to use the PC together with the TA POX Stollmann Entwicklungs und Vertriebs GmbH 3 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 2 Installation 2 3 Displays and control elements TA POX For interfacing the module TA HUX and TA SO
20. HUX TA POX TA SOC User manual r01 06 2009 5 Diagnostic and error messages 85 X Rejection of the connection request or 85 X NUl call no more granted 8 amp X PVC Access description erroneous 87 X PVC Clear by service provider e g DATEX P 8 X DNIC not accessible 89 X Reverse charging not agreed upon 8A X Missing agreement 8B X Missing number of calling station 8C_ X Erroneous number of calling station 8D X PVC Transmission section interrupted 8E X PVC Transmission section out of operation 8 F X PVC Time expired DATEX P state P1 90 X Erroneous coding of cause 91 X Erroneous direct call 92 X X Uncompleted octet found 97 X 75 Facility valid 94 X 75 Erroneous use of facility 95 X 75 Erroneous address in packet Call Accepted 96 X Invalid interrupt packet in subnet 97 X Invalid interrupt acknowledge in subnet 98 Only single packet with limitation of response entry permitted 99 PVC Incompatible PVC 9A X Erroneous agreement of window size 9B X Missing fields 90 X Erroneous address length 9D X Erroneous length of facilities 9E X Incomplete field 9F X Incompatible transmission rate class AO X Group call number out of order A1 X Group call number not accessible A2 X Group call number temporarily out of order A3 X Erroneous
21. Ox9C 29 0x9D 30 Ox9E 31 Ox9F 34 OxA2 No circuit channel available 38 OxA6 SDN network out of order 41 OxA9 Temporarily failure 42 OxAA switching equioment congestion 43 OxAB Access information discarded 44 OxAC Requested circuit channel not available 46 OxXAE Precedence call blocked 47 OxAF Resource unavailable unspecified 49 OxB1 Quality of service unavailable 50 OxB2 Requested facility not subscribed 53 OxB5 Outgoing calls barred within CUG 55 OxB7 ncoming calls barred within CUG 57 OxB9 Bearer capability not authorized 58 OxBA Bearer capability not presently available 63 0xBF Service or option not available unspecified x Bearer capability not implemented 3 13 78 o lololnlololololo DOO eL L nS SINT NSN 0 00 Gp C0 C0 0d C0 Co co olol lolo VOU eS SO 10 1 02 0 SIN NY 0 00 cd o o lo yini OLIKOEKOLIKOLEKSLIKOL S o sie uae Cale SI ITN Co as es es l IDI PSI PIDN 0 00 cd o_o w N o 1 0x81 2 0x82 3 0x83 6 0x86 16 0x90_ 17 0x91 18 0x92 19 0x93 20 0x94 21 0x95 22 0x96 26 0x9A_ 27 0x9B 28 0x9C_ 29 0x9D_ 30 0x9E_ 31 0x9F 34 0xA2 38 0xA6 41 0xA9 42 7 0xAA _ 43 0xAB 44 0xAC 46 0xAE 471 0xAF _ 49 0xB1 50 0xB2 _ 53 0xB5 55 0xB7_ 57 0xB9_ 58 0xBA 65
22. TA SOC User manual 3 Using the TA POX 3 Data Forwarding Characters This parameter defines a control character to be used as the Data Forwarding Character This character can be used to force the transmission of the collected data to the other end even when the defined packet size has not yet been reached Valid Parameter Values 0 Only send full packets thus no Data Forwarding Character Regardless of the value set in parameter 3 the data packet will always be forwarded under any of the following conditions when the input buffer holds a full data packet 128 bytes and parameter 15 is set to 0 zero when the input buffer is full 512 Bytes and parameter 15 is set to 1 in this case one data packet will be sent and the remaining data will be shifted forward in the input buffer after the first character of a PAD command is entered following the entry of the BREAK signal command INTD also see parameter 7 after the timeout of the timer set with parameter 4 4 Timer for Data Forwarding Defines the timeout interval following which the collected data will be sent as a data packet even if the defined packet size was still not reached The timer is reset each time a data packet is sent even if it was sent as the result of the Data Forwarding Character See parameter 3 Valid Parameter Values 0 No timeout thus no time interval 1 Immediate transfer thus each character is immediately transferred as a
23. To activate and use the new setting you have to run the go or reset command Note2 Command syntax for setting hlc Ilc and bc An empty parameter has to be entered by Example Deleting of LLC value LLC lt gt Entering a new LLC LLC 8890 lt gt Note3 Different modes for V 110 baudrate adoption Outgoing call brn 0 ISDN message SETUP will be created with or without LLC brn depending on the setting of dial v110llc The B channel V 110 baudrate will use the baudrate set by brn independent of br or recognized local baudrate brn 0 adaptive same mechanism as brn 0 the V 110 baudrate will be created by br rsp the recognized local baudrate Incoming call brn 0 no LLC received accept incoming call use in B channel brn for V 110 baudrate LLC received compliant to brn accept incoming call LLC received not equal to brn Reject incoming call DISCONNECT cause incompatible destination brn 0 adaptive no LLC received accept incoming call use in B channel br rsp the recognized local baudrate for V 110 baudrate LLC received accept incoming call use in B channel the baudrate derived from the LLC as V 110 baudrate The usage of the LLC is controlled by the TA Configurator command dial v110llc Stollmann Entwicklungs und Vertriebs GmbH 87 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set 4 6 Software update The TA POX uses a Flash EPROM for
24. U S you have to set the SPID You get it from your ISDN provider AT SPID1 xxx Set SPID 1 AT SPID2 xxx Set SPID 2 lt cmd gt Execute configuration command Executes one configuration command for definition of commands see page 66 AT lt cmd gt Stollmann Entwicklungs und Vertriebs GmbH 31 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 3 2 2 AT command S register set The available S Parameters are listed below and can be stored to the user profile by entering the AT amp W command The modem selects an S Parameter performs an S Parameter read or write function or reports the value of an S Parameter ATSn v Set S Parameter n to the value v ATSn Reports the value of S Parameter n If the number n is outside of the range of the available S Parameter or the value v is outside the range permitted for the given S Parameter the mode will return the ERROR message Some S Parameters are read only So Number of Rings to Auto Answer SO set the number of the rings required before the TA automatically answers a call Setting this parameter to 0 disables auto answer mode So 0 No automatic call acceptance acceptance of an incoming call is controlled by the data terminal command ATA after RING le Immediate call acceptance by the terminal adapter 2 n Call acceptance through the terminal adapter after n RING messages The serial status line RI will
25. address A4 X Erroneous sub address A5 X Erroneous format of net facility A6 X Length of net facility not equal 0 A7 X No user data A8 X Missing indicator for national facility A9 X Access to users of the same service blocked AA X Number temporarily not accessible AB X User recognition required in the packets Connection Request and Call Accepted AC X Called subscriber has not agreed upon the facility Single Packet 96 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 5 Diagnostic and error messages AD X Network internal Load Request received AE X Network component error AF X Network failure of a virtual connection BO X Network internal restart request received B1 X Erroneous number of called station in the packet Call Accepted B2 X Unknown network faculty B5 X X 32 dial access not available B6 X X 32 dial access not available B7 X Reserved CO X X 25 dial access Service data error C1 X X 25 dial access Service data error C2 X X 25 dial access User data erroneous C3 X X 25 dial access Procedural error C4 X X 25 X 32 dial access Modem error C5 X X 25 X 32 dial access Modem error C8 X X 25 dial access successful connection establishment c9 X X 25 dial access dialing proce
26. bit s Note Autobauding br 0 is available for AT command set only If set and cmds is changed to PAD br will be set to 4 9600 bit s OMONOARWNM OO brn line baudrate asynchronous V 110 Selection of the asynchronous baudrate for V 110 line B channel 0 Line baudrate equals local baudrate 1 1200 bit s 2 2400 bit s 3 4800 bit s 4 9600 bit s 5 19200 bit s See in addition note 3 bsize frame length Maximum length of a data frame This setting is valid for both received and transmitted data frames prot X 25 B 128 prot X 31 D 128 prot X 75 2048 values 32 2048 68 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set catab lt x gt show call table entry Show setting of the parameter catab lt x gt for automatic dialing The call table catab includes 3 entries catab1 catab2 catab3 catabx nn set entry number x to SDNnumber nn max length 20 digits catab1 clear entry catab1 show entry cato call timeout to abort Time to abort a call if not successful connected after n seconds n 3 255 default 15 seconds capa call pause Automatic call set a call pause for n seconds before next call attempt n 0 immediate call retry n 0 255 default 3 seconds catry calls retry Automatic call max no of tries of every number entry in catab n 1 255 default 1 ccts
27. default enable HDLC frames 03 di3 D channel layer 3 messages disabled 00 enable layer 3 messages 72 default sl1 serial line trace disabled 00 enable serial trace 05 default examples tremsk 00000077007205 D channel layer 1 and layer 3 serial data and status lines tremsk 00030000007205 D channel layer 3 B channel layer 2 serial data and status lines trcmsk 00000300007205 D channel layer 3 B channel layer 3 serial data and status lines Stollmann Entwicklungs und Vertriebs GmbH 101 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 5 Diagnostic and error messages treclr clear trace buffer treclr clear actual trace buffer contents trcread read trace buffer trcread Output of the complete trace buffer in hexadecimal chars ASCII max line length 72 chars Every entry of the trace buffer is output using the following format Entry number Timestamp Type Length Databytes Entry number Sequence number of entry Timestamp in units of 10 ms TypeAndSource Source of trace entry bit0 7 type from trace mask bit8 14 source of trace entry 0200 B channel layer 2 bl2 0500 D channel layer 1 dl1 0600 D channel layer 2 dl2 0700 D channel layer 3 dl3 0900 Serial status line serial data bit15 Oxxx incoming event from ISDN line 8xxx outgoing event to ISDN line FFFF Reset for firmware Length Length of following data bytes Databytes Data bytes continued li
28. reaction Send Interrupt packet Send Reset packet Send Interrupt and break packet Change to command mode can be useful when parameter 1 is set to 0 zero Discard local data and send Interrupt and break packet Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 8 Display Received Data ON OFF Defines whether received data should be displayed on the screen Valid Parameter Values 0 Display all received data 1 Don t display the received data 9 Fill Characters Following a Carriage Return lt CR gt Defines how many fill characters lt NULL gt the PAD should insert into the character string following a lt CR gt carriage return Valid Parameter Values 0 No fill characters lt NULL gt n Number of fill characters lt NULL gt following a lt CR gt nis an integer in the range from 1 to 255 Note This parameter is ignored for output to the screen since the fill characters serve no useful function on a screen display left over from the days of the teletype 10 Screen Line Width not supported 11 Local baudrate Read only Displays actual used baudrate on asynchronous line 1200 bit s 2400 bit s 4800 bit s 9600 bit s 19200 bit s 38400 bit s 57600 bit s 115200 bit s 230400 bit s OONDOARWND Stollmann Entwicklungs und Vertriebs GmbH 11 TA HIX TA HUX TA POX TA SOC
29. repair necessary O ISDN not ok Check ISDN interface connector O nxis TA POX not ok Hardware error TA POX repair necessary B1 B2 flashing Bootloader active no operational firmware programmed Use command at flash to download firmware with 115200 Bd N81 see page 88 LED Legend amp On occ short on long off Cycle 1 sec fl long on short off Cycle 1 sec nxms continuous blinking n times every m seconds O Off Stollmann Entwicklungs und Vertriebs GmbH 107 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 6 Appendix A3 TA HUX V1 Mechanical dimensions of the module V1 ei 3 P1 P3 ke als ca a a E E Te Ro Ils m w 4 ae E B Era wE E T TE kl E E 3 H pas Jab m Ega pe PP 5 z EF N PZ 108 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 6 Appendix A4 TA HUX V1 Serial Interface Connector P1 P1 Pin Signal Direction TA usage External from TA interfacing 1 GND l OV Power OV Power supply 2 VCC l 5V Power 5V Power supply 3 GND GND GND 4 TXD l 5 GND GND GND 6 RXD O 7 ID2 O GND on TA HUX NC or READ 8 RTS 9 ID1 O 10k Pull up on TA HUX_ _ NC or READ 10 CTS O 11 RESET l RESET active low OC NC 12 DTR l 13 L3 O internal
30. s Note The further on used B channel is that one from the active connection Example AT C3PTY 11 IH2 Intiate a 3 party conference To release a three party conference please enter the same command again then the previous state will be entered Call on call reference Ixx will be active call on the call reference IHxx will be in hold If one of the other two party of the three party conference is going on hook the previous state for the staying connection will be entered Example if the previous active connection releases the connection within the three party conference the three party conference will be closed and the staying connection will be in hold state 50 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX AT DISC I lt Call Reference gt C lt 34 hb gt Disconnect Disconnects existing ISDN connection within the given cause value 34 hb hexadecimal coded byte The causevalue hb is defined according to Q931 ETS 300 102 1 It is also possible to send an disconnect without an cause value normal call clearing The Call Reference is released by this command and is no longer valid Example AT DISC 11 Disconnect an existing connection with normal call clearing Example AT DISC 11 C3495 Disconnect an incoming call with the cause 0x95 call rejected AT RA I lt Call Reference gt Send alert message Send an Alert message to the
31. small 1003 Buffer exceeds 64k 1004 Message buffer size too small 1005 Too many logical connections 1006 Reserved1 1007 Message could not be accepted 1008 Register OS Resource Error 100a External Equipment not supported 100b External Equipment only 1101 Bad application ID 1102 Illegal cmd or message length 1103 Message queue full 1104 Message queue empty 1105 Message lost 1106 Unknown notification 1107 Message not accepted 1108 OS Resource Error 1109 CAPI not installed 2001 Bad State 2002 Illegal Identifier 2003 Out of PLCI 2004 Out of NCCI 2005 Out of LISTEN 2006 Out of Fax Resources 2007 Illegal Message Parameters Stollmann Entwicklungs und Vertriebs GmbH 99 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 5 Diagnostic and error messages 3001 3002 3003 3004 3005 3006 3007 3008 3009 300a 300b 300c 300d 3301 3302 3303 3304 3311 3312 3313 3314 3315 3316 3317 3318 3319 B1 protocol not supported B2 protocol not supported B3 protocol not supported B1 protocol param not supported B2 protocol param not supported B3 protocol param not supported B Prot combination not supported NCPI not supported Unknown CIP value Flags not supported Facility not supported Data length not supported Reset procedure not supported Layer1 protocol error Layer2 protocol error i e DTE address not correct TEI not correct Layer3 protocol error Another application got the call Fax remot
32. to RFC 1321 e Microsoft Chap according to RFC 2433 The simpler PAP transmits the user password as clear text over the line whereas CHAP uses encryption Which protocol is actually used depends on e the local PC if the dialup network configuration requests password encryption only CHAP will be used e the remote host configuration it may e g allow both PAP and CHAP CHAP only etc 3 6 1 Restrictions on Windows95 The CHAP protocol requires that the local side PC or TA responds with the proper encrypted password when ever requested by the remote host Since Windows95 does not respond on repeated requests CHAP can be used on the second link only if the TA knows the password It must be stored in the TA s NVRAM e Enter at chappwd lt password gt to input your password in the TA Warning The input echo is shown in clear text it should be hidden from unauthorized persons Nevertheless commands as AT amp V1 display the password as a sequence of asterisks e Enter AT amp W to store the setting in the TA If the password chappwad is not stored on the TA or is wrong and remote and or local dialup network configuration require password encryption the second link will be physically established for a short time and will then be disconnected As a consequence the Multilink option is disabled for the current connection Stollmann Entwicklungs und Vertriebs GmbH 45 TA HIX TA HUX TA POX TA SOC
33. 08 4 8 DCD 109 1 22 RI 1 25 9 25 pin jack 9 pin jack Attention allowed cable length lt 15m for transmission speeds gt 19 200 bit s lt 2m necessary if cable length gt 2m 114 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 6 Appendix A12 TA POX Cable layout to connect a PC with 9 pin male plug through a serial COM port PC TA POX 9 SGND 102 5 3 TD 103 3 2 RD 104 2 7 RTS 105 7 8 CTS 106 8 6 DSR 107 6 4 DTR 108 4 iL DCD 109 1 9 RI 25 9 9 pin jack 9 pin jack Attention allowed cable length lt 15m for transmission speeds gt 19 200 bit s lt 2m necessary if cable length gt 2m Stollmann Entwicklungs und Vertriebs GmbH 115
34. 10k Pull up NC or status info 14 DCD O 15 RI O 16 DSR O 17 UA O User Output 1 NC or status info 18 UE User Input 1 10k Pull up 19 UA2 O User Output 2 NC or status info 20 UE2 User Input 2 NC reserved Outputs UA default similar to L1 of TA POX ON ISDN activated else OFF L3 default equals L8 L4 of TA POX one or both B channel occupied B channel s connected but may be not synchronized UA2 reserved Inputs UE reserved UE2 reserved Stollmann Entwicklungs und Vertriebs GmbH 109 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 6 Appendix A5 TA HUX V1 ISDN interface connector P2 P2 Pin Signal Direction RJ 45 Pin 1 RX l 5 2 TX O 6 3 RX 4 4 TX O 3 5 RX BRA power O NC supply 6 TX BRA power O NC supply A6 TA HUX V1 IOM Interface connector P3 P3 Pin Signal Direction from TA usage TA 1 DD O IOM Data downstream 2 DU IOM Data upstream 3 FSC O IOM frame sync 4 DCL O IOM double bit clock 5 SDS O IOM B channel strobe 6 BCL O IOM bit clock 110 Stollmann Entwicklungs und Vertriebs GmbH TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 6 Appendix TA SOC V2 Mechanical dimensions of the module A7 top view J2 31 30 29 24 27 2 35 24 eB TS Y mgm 4424 125 mn f bat mm 20 mm e 125 mm MA oOOOTKOG oppooo X1 M 8 K4 BO
35. A configuration commands entered by a locally connected PC e by using TA configuration commands entered via the ISDN access remote configuration e by using the PAD X 3 command set entered by a locally connected PC e by using the AT command set entered by a locally connected PC The TA Configurator can be entered in the following ways e remote via ISDN see page 64 e by using a special command from the asynchronous dialup command interface PAD CONF or AT ATCONF e or escape sequence in power up phase if enabled rsttim gt 10 rstmsg 1 4 1 Configuring the TA POX with AT commands To execute one TA configuration command cmd out of the AT command mode you have to issue the command at cmd To call up the TA Configurator please use the command atconf You can leave the TA Configurator by the command quit or exit or go Note After altering one of the profile values marked by 7 you have to give the additional commands save and go This is necessary to save and activate these new parameters Stollmann Entwicklungs und Vertriebs GmbH 61 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set 4 2 Configuring the TA POX with X 3 PAD To execute one TA configuration command cmd out of the X 3 PAD command mode you have to issue the command exec cmd To call up the TA Configurator please use the command conf You can leave the TA Conf
36. A POX Error cause display lt Xx gt ISDN release error cause hexadecimal Example Tx data Rx data ATW1 OK ATD12345 NO CARRIER lt 34A2 gt In AT command mode error cause display does not belong to the AT command standard can be turned on by issuing the command ATW1 The shown error causes use the coding defined by the CAPI definition ISDN error causes from the ISDN network are always coded as 34xxH where xx represents the hexadecimal version of the ISDN error cause See page 91 All other causes are CAPI error causes see page 99 Note If autobauding is selected and after powering on the TA no AT command is entered a response from the TA i e RING will be sent with the baudrate 115200 bit s Date and time display In AT command mode the current date and time does not belong to the AT command standard can be turned on by issuing the command ATW4 The current date and time value is given as part of the connection message from the public switch The value is available in the verbose result code only ATV 1 Example Ixdata Rx data ATW4 OK ATD12345 CONNECT 64000 lt 12345 gt 13 05 06 16 30 38 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX X 25 userdata display In the AT command mode the received X 25 userdata of the X 25 CALL REQUEST PACKET can be displayed for an incoming call in the CONNECT message when the configured B
37. C please refer to the appendix 2 3 1 TA POX front view You can control the status of the TA POX via 8 LEDs at the front side st6 marn TA The 4 LEDs at the right show the status of the serial interface to the PC T shows activity of transmitted data from the terminal DTE to TA R shows activity of receiving data from the ISDN line TA to DTE DTR shows the status of DTR line i e the terminal is trying to connect via the TA POX DCD represents the status of the DCD line V 24 shows normally an active data connection The 4 LEDs at the left show the status of the ISDN interface B1 show the usage of the first B channel B2 show the usage of the second B channel If one or both LED s are ON the B channel is occupied due to an incoming or outgoing connection L1 show the activation status of the ISDN interface L2 show the connection state in coded form 4 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 2 Installation The following list describes the view for an error free power on sequence Status L1 L2 B1 B2 1 Bootloader start up wait amp 05s 2 Firmware start up wait O O 2sec 3 ready for operation ISDN ok amp O O O 4 ISDN data connection on B1 channel O LED Legend On Continuously blinking O Off A complete list you can find in the appendix LED displays 2 3 2 TA POX back view At the bac
38. E 1 TA reacts as DTE own cmd adr 01 AT DTE 3 TA reacts as DCE own cmd adr 03 Note The value will be changed by setting the B channel protocol ATBx ISDN Select D channel protocol Selects ISDN D channel protocol to the ISDN line The protocol must fit the protocol running on the ISDN line otherwise a connection cannot be set up Note after changing and storing the ISDN protocol the TA has to be reset by powering it off and on alternately you can use the command AT amp W RESET AT ISDN 0 Select DSS1 Euro ISDN default AT ISDN 1 Select 1TR6 Germany national Option AT ISDN 2 Select DSS1 NT mode Euro ISDN Option AT ISDN 5 Select Bellcore National ISDN 1 2 USA Option AT ISDN 6 Select NTT INS NET Japan Option AT ISDN 7 Select AT amp T 5ESS USA Option AT ISDN 8 Select VN 4 France Option AT ISDN Show selected ISDN protocol AT ISDN Show available ISDN protocols 30 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX K Set Layer 2 window size Sets window size x layer 2 protocol B channel x 1 7 default 7 AT k x The default value is dependent of the selected B channel protocol RPWD Password remote configuration Sets password for remote configuration to nn 1 32 chars AT RPWD nn Default empty just press return key SPID1 SPID2 Set SPID Option For ISDN lines in the
39. IX TA HUX TA POX TA SOC User manual r01 06 2009 1 Introduction 1 2 Service By using the call number 49 40 89088 291 you can connect up to an asynchronous support server which uses the B channel protocol X 75 please use command ATB10 to set up the correct B channel protocol By using the call number 49 40 89088 293 you can connect up to an asynchronous support server which uses the B channel protocol X 25 please use command ATB20 to set up the correct B channel protocol To LOGIN please use name guest password guest X 31 connection The German Telecom offers a test access point for X 25 echo generator with the following X 121 number Datex P 40400049912 HINT For access to the German DATEX P network from an X 31 D basic rate interface in Germany you have to use the dialing prefix 0262 preceding the X 25 calling number i e call 0262 40 4000 49912 After the connection is established the echo generator will echo all received text string in X 25 packets 1 3 License The following license numbers for the connection to the ISDN are given by CE for Europe EC Switzerland Norway TA POX and TA HUX are conform to the European safety requirements IEC 60 950 Please use only the delivered power supply or an original replacement from Stollmann Connect the TA POX only to the S bus interfaces indoor with SELV Safety Extra Low Voltage related to EN60950 The TA POX and TA HUX are conform to the European rules of EMC
40. OM VIEW ienie e aea a ae eae 4 2 3 2 TA POX front VICW src scticn ec hta a tae Alaa a ioa cea cadsm Vener sales a 5 3 Using the TA POX TA HUX TA 8S0C0 seseesssseneneeeeeeeeereernnnrrsseerrrrrnnnnresene 6 3 1 X 3 command set integrated PAD ee eeceeeeeeeeeceeeeeeeeeeseeseeeeeeeeeeeees 7 3 1 1 X 3 Parameter of the integrated PAD ccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeneees 8 3 2 ATcCommand S tan ute siete cla etetautl pete cig E A tae tg 17 3 2 1 ISDN specific AT COMMANGS ances sxazcisieazcced xezdiesoxavoasectescens seas ances 30 3 2 2 AT command S register SOU ae sic eo aie a ee a a ee 32 3 23 A TFres lt eode Sisa hia hans las la tala tA las ta ia ee nl Chin 37 3 3 Serial status NGS ioe ccesio cesses setae eicncenike aeade ei dale insg od epic epircniie dense 40 3 4 Automatic call eStablisMiMentresscce ctccccuiatdeetecarsicnateciebiniatccccaiatdesialats ianetattes 43 3 5 25 D channel rerouting cccccceceeeeesseeecceeeeeeeeeeeeseneeeeeeeeeeeeeeeeeseaeees 44 3 6 Using Multilink PPP option ae ae ae ole eh 45 3 6 1 Restrictions on Windows95 2 jist sce ee esiuties Sadat e cet ceiuds Uecal nee ualutyes tedatedesy 45 3 6 2 Bandwidth on demand BOD cccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaaees 46 3 7 ext IOM 2 interface Option ccceeeeeeeeeeceeeeeeeeeeeeeeneeeeeeeeeeeeeeeeeeeaeees 47 3 7 1 ext IOM 2 interface command Set cceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneae
41. ON deactivated ON activated 3 ISDN activation OFF deactivated ON activated 10 OFF HOOK B1 channel occupied 11 OFF HOOK B2 channel occupied 12 OFF HOOK B1 or B2 channel occupied 29 data connection B1 or B2 channel connected and synchronized 30 connection establishment in coded form e dial procedure slow flashing e synchronization procedure quick flashing 31 B1 channel connected and synchronized 32 B2 channel connected and synchronized 22 customer define DATA_CHCONNECT_ EXT 40 customer define ALARM OUTPUT 41 customer define INC EXT CALL 43 equals L1 of TA POC L1 without refresh only refresh output with active call Default values rmua 131 TA HUX rmuat 30 TA HUX rmua2 140 TA HUX rmua3 z NOTE incoming remote connection to the TA will also be signaled with the B channel LED s B1 of B2 80 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set rmsn Multiple Subscriber Number for remote MSN Multiple Subscriber Number for remote configuration no specific MSN all incoming calls accepted default rmsn global msn all incoming remote calls will be accepted rmsn nn set rmsn to nn string of digits max length 20 rmsn no acceptance of incoming remote calls rmsn show current setting of rmsn NOTE The remote connection needs to get an incoming call with a special LLC value 88 90 21 58 00 BB
42. OT LG BS erelererererere st Cre 000C 61 bZ 6 64 Bo 35 36 77 30 3 40 41 tact Side view bottom components max 0 mm Stollmann Entwicklungs und Vertriebs GmbH 111 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 6 Appendix A8 TA SOC V2 connector X1 to X6 Pin Con Signal Dir active TA SOC usage 1 X3 TX O ISDN Transmit RJ45 jack Pin 3 2 X3 TX O ISDN Transmit RJ45 jack Pin 6 3 X3 RX ISDN Receive RJ45 jack Pin 4 4 X3 RX ISDN Receive RJ45 jack Pin 5 14 IOM BCL O IOM Bit clock LT S Mode Input 15 IOM DU i IOM data upstream LT S Mode Output 16 IOM DD O IOM data downstream LT S Mode Input 17 IOM_ FSC O IOM Frame sync LT S Mode Input 18 IOM_ DCL O IOM Double bit clock 19 IOM_ SDS O IOM channel strobe 24 Xi RESET L Reset may be left open 25 X1 nc 26 XI1 GND GND Signal 27 X1 UA O H To connect to LED1 28 X1 L3 O H To connect to LED2 29 X1 nc 30 X1 UA2 O H General purpose Output 31 X1 UE H General purpose Input 32 X11 UE1 H General purpose Input 33 X4 RTS L Request to Send 34 X4 RXD O H Receive Data 35 X4 TXD H Transmit Data 36 X4 RI O JL Ring Indicator 37 _ X4 DSR O IL Data Set Ready 38 X4 CTS O JL Clear to Send 39 X4 DCD O JL Data Carrier Detect 40 X4 DTR L Data Term
43. User manual r01 06 2009 3 Using the TA POX 12 Local flow control Read only Handles and displays used flow control on asynchronous line 0 no flow control 3 flow control RTS CTS 4 flow control XON XOFF Extended Parameters 13 through 24 14 Line Feed Fill Characters Defines whether fill characters lt NULL gt should be sent following a line feed lt LF gt Valid Parameter Values 0 No fill characters lt NULL gt after a lt LF gt n Following a lt LF gt on the screen append n fill characters lt NULL gt nis an integer in the range from 1 to 255 15 Control Input Buffer Editing Defines whether characters in the input buffer may be edited Valid Parameter Values 0 No editing the values of the parameters 16 17 18 and 19 will be ignored 1 Editing enabled and the editing features set by the parameters 16 17 18 and 19 may be used in this case it is not possible to do a preemptive transmission of a data packet using the Data Forwarding Character see parameter 4 16 Delete Character Defines the Character Delete character thus the ASCII value of the character that when entered will delete the previously entered character Only possible when parameter 15 is set to 1 PAD has editor capability Valid Parameter Values n nis an integer in the range from 1 to 255 and gives the ASCII value decimal of the desired Character Delete character default 8 gt lt BACKSPACE gt key
44. User manual r01 06 2009 3 Using the TA POX 3 6 2 Bandwidth on demand BOD Enabling this feature will cause the TA POX to use the Multilink PPP protocol to enhance the ISDN throughput using the second B channel automatically if the throughput of the internet connection is higher than a definable value a second B channel connection will be established automatically and used for data transfer if the throughput of the internet connection is lower than a definable value the second B channel connection will be disconnected automatically at bod 0 at bod 1 at bodiv lt incrValue gt at bodit lt incrTime gt at boddv lt decrValue gt at boddt lt decrTime gt disable BOD default enable BOD Throughput level to add 2 B channel connection in kbit s default 40 duration that bodiv has been reached to add 2 b channel in secs default 30 Throughput level to release 2 B channel connection in kbit s default 40 duration that boddv has been reached to release 2 b channel in secs default 30 Note call bumping cmlp has higher priority than bandwidth on demand 46 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 3 7 ext IOM 2 interface option The following chapter will describe the ext IOM 2 interface of the TA HUX and TA SOC module This option is not available in the external product TA POX The call cont
45. ands here as a preview show show the usually used parameter showall show all changeable parameter quit leave TA Configurator help show all available commands defa setup default parameter set defa 1 setup factory default parameter set save store parameter non volatile at sx at opt at rcs S Register AT command parameter set Handle AT command set specific settings Show and change AT S registers by entering the new value AT Sn v set Register Sn to value v AT Sn show current value of S Register Sn The complete list of S Register is described in chapter 3 2 2 AT command S register set at opt show option register bit values bitO 01 gt ATE1 bit 02 gt ATQ1 bit2 04 gt ATV1 bit5 32 gt ATW1 at rcs equals setting of Hayes ATX command 66 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set bch1delay ISDN B channel loop delay ATS31 1 needed This parameter set the data loop delay in the ISDN B channel when S register 31 1 which activates the B channel loop for incoming calls The used B channel for the loop is given from the public switch within the incoming call message DSS1 SETUP l element Channel Identification 0x18 bchidelay ISDN B channel data loop delay in 64 byte steps bch1delay 256 3968 default 256 Byte The delay time in the B channel can be controlled by changing the buffer size of the in
46. are available B shows B channel used hexadecimal coded byte 01 Bchannel 1 occupied 02 B channel 2 occupied Example 1 11B01 Stollmann Entwicklungs und Vertriebs GmbH 53 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX DISC I lt Call Reference gt C lt hbhb gt disconnect received Indicates that a call has been disconnected The cause is indicated with causevalue hb hexadecimal coded word The causevalue hb is defined according to CAPI 2 0 see also TA POC manual CAPI causes Example DISCI1C3491 Outgoing call is cleared with the ISDN cause 0x91 User busy NOTE In case of the DISC message available inband information in the selected B channel will be sent to the IOM 2 interface ERROR Syntax error in AT command There was a syntax error or not known AT command issued INFO I lt Call Reference gt De lt rn gt information to existing call reference Information initated by a status change for an existing call reference with D shows destination address the dialled number Example 1INFO 11D9 next dialled number 9 received REL I lt Call Reference gt C lt hbhb gt disconnect received Indicates that a call has been disconnected The cause is indicated with causevalue hb hexadecimal coded word The causevalue hb is defined according to CAPI 2 0 see also TA POX manual CAPI causes Example RELI1C3491 Outgoing call is cle
47. ared with the ISDN cause 0x91 User busy NOTE In case of the SREL message no inband B channel information is available and the selected B channel for the last call is free 54 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX RING I lt Call Reference gt Dern gt O lt rn gt B lt hb gt incoming call RING I lt Call Reference gt D lt rn gt O lt rn gt B lt hb gt S lt nn gt ATB45 only Indicates an incoming call a SETUP is received D shows destination address the dialled number dialled msn O shows origination address the dialling number B shows B channel used hexadecimal coded byte 00 no B channel occupied if call waiting and both B channels occupied 01 Bchannel 1 occupied 02 B channel 2 occupied S sets the service indicator available values 01 02 04 16 01 speech 02 unrestricted digital information 04 3 1kHz audio 16 telephony lt rn gt ISDN number string of digits 1 22 With protocol set to B40 all speech based calls will be signalled S 01 04 and 16 CIP value 00030012 Example 1 RINGI1D2340567B01 Indicates an incoming call for port 1 with destination address 234 and origination address 567 and using B channel 1 Example 2 RINGI1D2340567B01S01 Indicates an incoming speech call for port 1 with destination address 234 and origination address 567 and using B channel 1
48. by flashing of the LEDs Bootloader active To store a new firmware correctly you have to enter the command AT FLASH again and load a firmware using the XMODEM protocol as described above This bootloader supports only AT cmd with a fixed baudrate of 115 200 Baud Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 5 Diagnostic and error messages 5 Diagnostic and error messages For the diagnostic of erroneous situations the following functionality is supported Please check first the behavior of LED displays if an ISDN connection can not be established Refer to list of LED displays on page 107 5 1 Error messages from AT command set In AT command mode error cause display does not belong to the AT command standard can be turned on by issuing the command ATW1 The shown error causes use the coding defined by the CAPI definition ISDN error causes from the ISDN network are always coded as 34xxH where xx represents the hexadecimal version of the ISDN error cause See page 91 All other causes are CAPI error causes see page 99 Error cause display lt Xx gt ISDN release error cause hexadecimal Example Tx data Rx data ATW1 OK ATD12345 NO CARRIER lt 34A2 gt 5 2 Error messages of the integrated PAD For the diagnostic of erroneous situations e g no X 25 connection possible the following error indicators are supported If an error occurs during the establishm
49. channel is set to X 25 B channel or X 25 D channel prot 20 21 And the extended result code is set to ATW1 For X 25 D channel prot 21 the received X 25 userdata will be displayed in the RING message as well The display of the received X 25 userdata is set in brackets lt gt include a delimiter D followed by the number sign in hex coded form Example lt D 0100000074657374 gt 01000000 protocol identifier national use 74657374 X 25 userdata test Example for X 25 B channel include protocol ID and X 25 userdata test Tx data Rx data ATW1 OK RING ATA CONNECT 64000 lt D 0100000074657374 gt Example for X 25 D channel without protocol ID but include X 25 userdata 12345 Tx data Rx data ATW1 OK RING lt D 3132333435 gt ATA CONNECT 64000 lt D D 3132333435 gt Stollmann Entwicklungs und Vertriebs GmbH 39 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 3 3 Serial status lines The behave of the output serial status lines DSR CTS DCD RI and the input serial status lines DTR RTS can be configured as described in chapter 3 1 and 4 1 to 4 3 After power on all serial status lines from the TA will be inactive The serial status line DSR can be configured to signal the activation of the current command set cdsr 0 When changing the command set cmds the DSR line goes off during this change phase The serial input status lines DTR a
50. connection If DTR will be dropped immediately after sending serial data there is no guarantee to transmit these data to the destination side A delay of configured txfwd time 10ms between sending the last data byte and dropping the DTR line would send out the last data stream Stollmann Entwicklungs und Vertriebs GmbH 41 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX RTS Request to send flow control This serial status line is used for the flow control between the DTE device and the TA DCE 0 No flowcontrol 3 Hardware flowcontrol RTS CTS in the data mode 5 Hardware flowcontrol RTS CTS in data mode and command mode e lf the DTE activates the flow control RTS off the TA needs up to 3 character to stop the serial data stream to the DTE e f the connection will be cleared during an active flow control RTS off the received data will be sent to the DTE device when RTS gets active The reported result code will also be sent with RTS on The control lines to indicate the active connection DCD and the off hook state DSR will be changed without recognizing the current flow control state CTS Clear to send flow control This serial status line is used for the flow control between the TA DCE and the DTE device 0 No flowcontrol 3 Hardware flowcontrol RTS CTS in the data mode 5 Hardware flowcontrol RTS CTS in data mode and command mode e lf the TA activates the flow contro
51. d This does not of course affect our legal liability for damages based on any intent or gross negligence With respect to the data given in this manual Stollmann does not warrant the non existence of industrial property rights trademarks patents utility models etc Nor are trade names brand names company names and product names in general use but are subject to the relevant trademark patent utility model and registered design rights The information must neither in whole nor even in part be copied translated reproduced or in any other way transferred to or stored on any electronic medium or other machine The purchase and use of software are governed by the General Conditions of Delivery and Payment as well as the Terms of License of Stollmann Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual Table of Contents Table of contents 1 inigo 0 6 itoa P E tne car rene soac ten trier oe nner ine Pr RPC eR ar CrP ner Tn tree ONT 1 1 1 Prod ctdescriptlons sarriena a nds aa 1 slam wg E EEE A EEE EAEE E E E A ETER 2 1 3 LICENS E ei E dak ueuddcmetdusdaneentcnosauteciee 2 2 MSTA AUG Os seeni ai i e E E tes E a E EE AE 3 2 1 CONEIS 22 ck Rae i aaa aa a a A 3 2 2 Installation ProC Cure eccceccccccceeeeeeeeeeeneeeeeeeeeeeeeeeeeeaaeaeeeeeeeeeeeeeeneaaeees 3 2 3 Displays and control elements TA POX cccccceeeeeeeeeeeteeeeeeeeeeeeeeeeenaaees 4 Zeal TAECOX T
52. data packet n n time interval in units of 50 msec 1 20 of a second and the value must be an integer in the range from 2 to 255 Example n 40 gt time out interval of 2 0 seconds A data transfer timeout is only permitted when parameter 15 is set to 0 zero Stollmann Entwicklungs und Vertriebs GmbH 9 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 5 Control of additional devices not implemented all values ignored 6 Displaying PAD Messages Defines whether the PAD messages should be displayed PAD messages are service signals that the PAD generates in response to PAD commands Valid Parameter Values 0 1 5 9 13 17 21 32 64 No display of PAD messages Display of X 28 PAD Messages ITU without PAD Prompt Display of X 28 PAD Messages ITU with PAD Prompt Display of DATEX P PAD Messages without PAD Prompt Display of DATEX P PAD Messages with PAD Prompt Display of extended PAD Messages without PAD Prompt Display of extended PAD Messages with PAD Prompt To add one of the following features add the described value to one of the previous selected Suppress X 25 address and ISDN no when connected Display CAPI error cause 7 Handling the BREAK Signal Defines how the PAD should react when it receives a BREAK signal from the terminal of the other communications partner command INTD Valid Parameter Values 10 oun _o No
53. ds prot 10 lt gt set protocol to X 75 save lt J gt save the new configuration quit lt gt leave the TA Configurator and activate the new value settings Hint The active set of parameters can be displayed on screen by the TA Configurator with the command show lt gt e Leave the terminal program and start your application Now you can use the TA POX with the new set of parameters by running the needed PC program Stollmann Entwicklungs und Vertriebs GmbH 63 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set 4 4 Remote Configuration using the TA Configurator commands The TA POxX to be configured is referred here as remote TA POX The TA POxX to configure is referred as local TA POX Please make sure that the remote TA POX to be configured at the other end is connected to the ISDN line and powered up Connect the local TA POX to ISDN interface Connect the PC s com port to the DTE interface of the local TA POX Connect the power supply to the mains socket Start a terminal emulation program i e Windows Terminal Configure the local TA POX with the B channel protocol X 75 and blocksize 2048 ATB10 Set up an ISDN connection to the remote TA POX to be configured by using the command ATD lt SDN No gt e lt l gt The extension e at the end of the calling number gives a connection to the internal remote access of the remote TA POX The called TA POX TA Configurator ack
54. dure running now FF X X X X System error Notes X The diagnostic indication will be used by the above shown packet The diagnostic indication will not be used by the above showed packet PVC The above showed packet will use this diagnostic indication only with PVC Permanent Virtual Call X 75 The diagnostic indication will be used with international connections Only valid for special network components concentrator Stollmann Entwicklungs und Vertriebs GmbH 97 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 5 Diagnostic and error messages 5 4 3 X 25 causes in Restart packet Coding of the field Reason for Restart in the packet Indicate Restart 01 Local sequence error 03 Temporarily disturbance in the network 07 Network ready 5 4 4 X 25 causes in Reset packet 00 Triggered by DTE 01 Out of operation virtual connections only 03 Remote sequence error 05 Local sequence error 07 Temporarily network disturbance 09 Remote station ready virtual connections only OF Network ready virtual connections only 11 Incompatible destination 98 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 5 Diagnostic and error messages 5 5 CAPI causes and their explanation Coding of the CAPI cause in hexadecimal form 0000 No error 0001 NCPI ignored 0002 Flags ignored 0003 Alert already sent 1001 Too many applications 1002 Logical block size too
55. e The call reference is created and reported by the ISDN module incoming call as parameter to the RING message Outgoing call as result to the CR command The call reference has to be released by the application with the command DISC or REL All commands based on the same connection have to use the same call reference More than one call reference can be active at a time The B channel information is reported from the TA within the parameter Bxx The ATS7 register Wait time for Carrier is not supported for IOM 2 interface connections The supported commands are described as followed Supported commands ATS80 Set pause between RING messages ATS80 Show actual values decimal of selected register nn ATS80 xxx Set pause between displayed RING messages 0 RING message not repeated D channel message ALERT not sent automatically 1 255 pause to repeated RING messages in 100ms steps D channel message ALERT sent automatically Default 50 5 seconds Note overlap receiving not possible ATS80 Show current values decimal of register S80 AT A I lt Call Reference gt Accept incoming call Using this command you can accept an incoming call if automatic call acceptance is not set Register ATSO 0 An incoming call is indicated by the result message RING include the callreference value and the selected B channel See also the chapter AT result messages in this document The Call Reference
56. e automatic local baudrate detection autobauding will also support the local data format detection for 10 bit character format 7 E 1 7 0 1 8 N 1 PRTY Set parity of asynchronous characters Selects the parity for asynchronous characters 0 no parity 1 even parity 2 odd parity AT PRTY 0 No parity default AT PRTY 1 Odd parity AT PRTY 2 Even parity Note To use other data formats than 10 bit 8N1 7E1 701 the local serial speed BR has to bet to a fixed speed The automatic local baudrate detection autobauding will also support the local data format detection for 10 bit character format 7 E 1 7 0 1 8 N 1 Stollmann Entwicklungs und Vertriebs GmbH 29 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 3 2 1 ISDN specific AT commands Setting up special ISDN parameter only one command is allowed per AT command BSIZE Set B channel block size Defines the maximum length x of a data block transmitted or received in B channel This parameter value depends of the configured B channel protocol e prot 10 BSIZE 2048 e prot 20 BSIZE 128 e prot 21 BSIZE 128 AT BSIZE x Note The value will be changed by setting the B channel protocol ATBx DTE Set B channel Layer 2 address Selects the Layer 2 link addresses Only valid for X 25 B protocol AT DTE 0 calling side reacts as DTE called side reacts as DCE default X 75 standard AT DT
57. e following parameters are read only can be changed using configuration commands 11 12 21 Stollmann Entwicklungs und Vertriebs GmbH 15 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX Table of the X 29 standard profiles a ai i ii il il eter ca ee ee eee eee Se ee Note Parameter in Brackets are not implemented or not setup by command profxx 16 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 3 2 AT command set All parameter can be changed by using an extended AT command set described in this chapter Please check if the factory setting will fit with your environment The factory setting is described highlighted in the parameter list shown in chapter AT command set see below If you want another configuration as set in the factory default setting please do the following steps Connect the TA POX to ISDN interface Connect the PC s com port to the DTE interface of the TA POX Connect the power supply to the mains socket Start a terminal emulation on your PC please verify that the baudrate setting of the terminal emulation fits those of the TA POX e Set up the parameter of the TA POX from the terminal emulation and save the parameter using the AT command set Example To change the used B channel protocol to X 75 please enter the following commands ATB10 lt gt set protocol to X 75 AT amp W lt
58. e station is not fax Fax training failed Fax disconnect before transfer Fax disconnect remote abort Fax disconnect remote procedure Fax disconnect local transmitter underrun Fax disconnect local receiver overflow Fax disconnect local abort Fax illegal transmit data 34xx Error cause from the ISDN line xx represents the ISDN cause see page 91 100 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 5 Diagnostic and error messages 5 6 Diagnostic using the internal Trace For more sophisticated debugging an internal trace functionality is implemented This logging mechanism allows to write activities of the ISDN and the serial interface into a wrap around buffer The type of entries can be selected by a trace mask tremsk set trace mask trcmsk par Setup the mask to select the type of data to be written into the trace buffer Default D channel Layer 1 and 3 DTE interface lines DTE Data in connection setup and clearing phase The parameter par has to be setup in the following way all bytes have to be entered default 00 00 00 77 00 72 05 02 par bl1 bl2 bl3 dl1 dl2 dl3 sli app bl1 reserved 00 bI2 B channel frames layer 2 disabled 00 default enable HDLC frames 03 bI3 B channel packets layer 3 disabled 00 default enable X 25 packets 03 dli D channel layer 1 status disabled 00 enable C I codes and sttes 77 default di2 D channel LAPD frames disabled 00
59. eeeeeeeeeeeeeeeeeeeeenaaeeeeeeeeeeeeeeeas 65 4 5 List of TA Configurator COMMANAS seeeeeeeeeseeseessssseeesesssseesseeeees 66 4 6 Software UPAALC cece eecccccecccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeeeeeess 88 5 Diagnostic and error MESSAGES ceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeenenneeeeeeeeees 89 5 1 Error messages from AT command Set cccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaees 89 5 2 Error messages of the integrated PAD cccceeeeeeeeseeeeceeeeeeeeeeeeeeeeeaeees 89 5 3 Table of ISDN causes and their explanation DSS1 cece 91 5 4 X 25 causes and their explanation cccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 93 5 4 1 X 25 causes in Clear packet cceeecceeecccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneaees 93 54 2 4X25 GlAQNOSIIC CODES a icceictictacctticts chistes ttictete Miele tate E 94 5 4 3 X 25 causes in Restart packet ccccccscccecceeeeeeeeeeeeneeeeeeeeeeeeeeeeeneeees 98 5 4 4 X 25 causes in Reset packet ccccccseccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeneaees 98 5 5 CAPI causes and their explanation ccceeeeeeeeeeeeeeneeeeeeeeeeeeeeenenaeees 99 5 6 Diagnostic using the internal Trace cc cccceeeeeeeeeeeeeeneeeeeeeeeeeeeeeeeaaees 101 6 fA 8 0121 8 b CeeemeNeR PRPC RE CECE ERE PET E a EES 106 A1 Technical data TA POX TA HUX TA SOC cece ccecceseeeseeeeeeeeeees 106 ii
60. ent of an X 25 connection a reason for the failure of the connection establishment or the release of an established connection will be indicated in accordance to the configured indication type See parameter 6 Indication according to ITU Datex P with English extension The following error indicators are supported Stollmann Entwicklungs und Vertriebs GmbH 89 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 5 Diagnostic and error messages e Error codes during establishment of an X 25 connection Indication as part of the Connection Release Message E g CLR OCC diag or CLR DER 0 lt zzzzH gt or Datex P connection released or connection released reason xx diag yy lt zzzzH gt xx shows the hexadecimal coding of the X 25 release cause and yy shows the hexadecimal coding of the diagnostic zzzz shows the hexadecimal coding of the CAPI cause 90 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 5 Diagnostic and error messages 5 3 Table of ISDN causes and their explanation DSS1 Cause Meaning Translation Translation Decimal X 25 Hexadecimal cause diagnostic 1 0x81 Unallocated unassigned number 2 0x82 No route to transit network OD 78 3 0x83 o route to destination OD 78 N 6 0x86 Channel unacceptable established channel 16 0x90 17 0x91 18 0x92 19 0x93 20 0x94 21 0x95 22 0x96 26 Ox9A 27 0x9B 28
61. eps to display the incoming call message RING or 2 The default value is set to 50 which equals 5 seconds 91 special command response behaviour WINDOWS 2000 WINDOWS XP compatibility 91 controls the responses of entered configuration commands ATS91 0 normal response behavior default ATS91 1 all unknown AT commands will be answered with OK ATS91 2 Windows 2000 compatibility some AT commands will be answered with OK see list below unknown AT commands will be answered with OK Windows2000 AT command set change ATNxxx all commands ATNxxx will respond OK without any functionality behind it V 110 baudrates can be set with AT BRN ATBxxx All commands ATBxxx will respond OK without any functionality behind it The B channel protocol settings can be set with AT PROT AT Nxxx All commands AT Nxxx will respond OK without any functionality behind it The B channel protocol settings can be set with AT PROT 36 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 3 2 3 AT result codes Result codes numerical and verbose Code Text Meaning 0 OK Command completed 1 CONNECT lt rn gt Connection established rn call number of remote site 2 RING lt rn gt Indicates an incoming call SETUP received 3 NO CARRIER lt xx gt No synchronization xx ISDN error cau
62. erformed the protocol X 75 ATB10 has to be setup before use 2 ATDS nnnn lt cr gt Dial out of the stored phone number table Example AT amp Z1 1234567 lt cr gt ATDS 1 lt cr gt Enter AT amp Z1 1234567 to store the number and ATDS 1 to dial it To dial the second phone number in the list you would enter AT amp Z2 to store it and ATDS 2 to dial it Examples for X 25 and X 31 calls ATD12345678 lt cr gt X 31 dial X 25 number 12345678 X 25 B dial ISDN call to 12345678 without a specific X 25 number ATD12345678X4000123456 lt cr gt X 31 ISDN number 12345678 will be ignored if X 25 number is set dial X 25 number 4000123456 X 25 B dial ISDN call to 12345678 with X 25 number 4000123456 22 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX ATD12345678X4000123456Ddatadata lt cr gt X 31 X 25 B ISDN number 12345678 will be ignored if X 25 number is set dial X 25 number 4000123456 and X 25 user data datadata dial ISDN call to 12345678 with X 25 number 4000123456 and X 25 user data datadata ATD12345678XP64 R 002 Nnuivalue 4000123456Pdatadata lt cr gt X 25 B dial ISDN call to 12345678 with packet size 64 byte with active reverse charging with outgoing call from closed user group CUG 02 with NUI selection string nuivalue with X 25 number 4000123456 and X 25 user data datadata include
63. ering it off and on alternately you can use the command AT amp W RESET AT ISDN 12 Select LL 64SB1 leased line 64S B channel 1 AT ISDN 13 Select LL 64SB2 leased line 64S B channel 2 AT ISDN 14 Select LL 64S2 leased line 64S2 B channel 1 AT ISDN Show selected ISDN protocol AT ISDN Show available ISDN protocols In the leased line mode the adapter can handle the B channel protocol ATB4 HDLC transparent only B B channel protocol Transmission protocol for data communication in the B channel ATB4 HDLC transparent octets are packed into HDLC frames 58 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 3 8 1 ISDN connection example To establish a data connection the adapter will start the outgoing call as usual independent of the configured command set cmds of the TA POX The called party number is not specified for the outgoing call Note The call request outgoing call must be done on both ends of the ISDN leased line with the TA POX 3 8 1 1 ISDN connection with AT command set 1 Start the outgoing call ATD1 lt cr gt 2 When the TA POX will detect the ISDN line activation of layer 1 the adapter will result the connection message and control lines CONNECT 64000 and serial status line DCD gt ON 3 To disconnect the logical link you can use the available mechanism to clear the connecti
64. es 47 3 1 2 AT result messages iren aaa a aaa ees eee 53 Stollmann Entwicklungs und Vertriebs GmbH i TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 Table of contents 3 7 3 IOM 2 connection control examples cccceeeeeesseeecceeeeeeteeeessseeeeees 56 3 7 3 1 Accepted incoming Call cccccesessceeceeeeceeeeeeeeeeeeeeeeeeeeeeeeeees 56 3 7 3 2 Rejected incoming Callllss cccesvese doce tude coos recites entaaeeciaciestandiameteewe 56 3 7 3 3 Successful outgoing call and disCOnneCt eeeeeeeeeeeeeeeeees 57 3 8 ISDN leased line Option esssesssennerneeeseeenrrnrrrnsserrrrrrnnnnnnssertnnnnnnnneeent 58 3 8 1 ISDN connection example ssssesesnsessssesrrrrrrrsseerrrnrnnnnnnserrrnrnnnneneeet 59 3 8 1 1 ISDN connection with AT command set ccceeeeeeeeeeeteteeeeeeeees 59 3 8 1 2 ISDN connection with automatic call establishment 60 4 TA Configurator command Set ccceeeeeeeeeeeeeeeneeeeeeeeeeeeeeeeeeeeeeeeeeeeeteee 61 4 1 Configuring the TA POX with AT COMMANGCG ccceeeeeeeeeeeeetteeeeeeeees 61 4 2 Configuring the TA POX with X 3 PAD cccceeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 62 4 3 Configuring the TA POX after power ON ccceeeeeeeeeeeeeeteeeeeeeeeeeeeeees 63 4 4 Remote Configuration using the TA Configurator commands 64 4 4 1 Remote access COntrol ccccccceceeeeeeeeee
65. f a connection cannot be established successfully an automatic retry will be started The duration of trying to establish the connection and the pause for next retry can be configured The dialed number is taken from the parameter catab cmds 6 Automatic connection establishment when DTR is ON Note cmds 6 and cdtr 4 can be used on different sides to accept incoming calls if DTR level is set to OFF cmds 7 Automatic connection establishment when the TA receives any data byte cmds 8 Automatic connection establishment independent of any status line Note autobauding is not supported set br not equal to 0 cato n call abort of a not successful call after n seconds n 3 255 default 15 seconds capa n call pause for n seconds before next call attempt n 0 immediate call retry n 0 255 default 3 seconds catabi nn set ISDN number nn catab1 clear entry catab1 show entry Maximum length of ISDN number 20 digits Hint The configuration command idle can be used to automatically disconnect after a predefined time without data transmission Note Please take care that parameter rsttim is greater than 10 and rstmsg 1 to enable the entry into the TA Configurator after reset default 40 4 sec Stollmann Entwicklungs und Vertriebs GmbH 43 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 3 5 X 25 D channel rerouting If the protocol X 25 D channel prot 21 is selected a
66. h 20 digits AT amp Zx shows the value of entry x AT amp Zx lt cr gt clears the value of entry x Example AT amp Z1 1234567 lt cr gt ATDS 1 lt cr gt Enter AT amp Z1 1234567 to store the number and ATDS 1 to dial it To dial the second phone number in the list you would enter AT amp Z2 to store it and ATDS 2 to dial it Z Define own msn compatibility to older firmware Defines the msn nn multiple subscriber number for the data port If the number is set to default all incoming calls are acceptable The msn can be displayed by command AT amp V AT Z nn set parameter msni and msno to nn max length 20 digits Note If 1TR6 D channel protocol is selected only one or the last digit is valid This parameter is not saved automatically AT Z needs two saving procedures It will save the value msni and msno separately 28 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX DBITS Number of data bits x asynchronous chars 7 8 Number of data bits for asynchronous character 7 default 8 AT DBITS 7 8 AT DBITS 7 If the configuration parameter DBITS is set to 7 data bits the parity bit has to be activated PRTY 1 or PRTY 2 The count of stop bits SBITS can be 1 or 2 Note To use other data formats than 10 bit 8N1 7E1 701 the local serial speed BR has to bet to a fixed speed Th
67. hannel data 10 X 75 SLP 13 V 120 async 20 X 31Bchannel X 25 B channel 21 X 31 D channel 22 T 70NL 23 T 9O0NL 31 MLPPP Option 33 X 75 B channel bundling Option For this type of protocol both B channel on the ISDN interface need to be free Otherwise the connection will fail no automatic detection 40 B channel transparently switched to OM 2 audio connection 43 B channel transparently switched to OM 2 data connection 45 B channel transparently switched to OM 2 data and audio connection 78 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set prty asynchronous parity Parity of asynchronous character default no parity 0 No parity 1 Odd parity 2 Even parity Note To use other data formats than 10 bit 8N1 7E1 701 you have to set the parameter of the serial bps rate br to a fixed speed br unequal 0 ptp ISDN interface type Select type of ISDN interface 0 select multipoint mode to connect ISDN terminals default 1 select point to point mode to connect ISDN switching systems quit exit go activate parameter changes Activates the actual parameter settings and leave the TA Configurator without storing the parameter in non volatile memory racctab Access table setup for remote access Using these commands you can setup a table to allow only dedicated callers for
68. he IOM2 interface of the TA HUX are preceeded by an EEN There are no spaces between the different parameters of the messages CONNECT I lt Call Reference gt D lt rn gt O lt rn gt Bchb gt Connection established CONNECT I lt Call Reference gt D lt rn gt O lt rn gt B lt hb gt S lt nn gt ATB45 only Indicates that the connection with the remote side is established using Call Reference D shows destination address the dialled number O shows origination address the dialling number B shows B channel used hexadecimal coded byte 01 Bchannel 1 occupied 02 B channel 2 occupied S sets the service indicator available values 01 02 04 16 01 speech 02 unrestricted digital information 04 3 1kHz audio 16 telephony lt rn gt ISDN number string of digits 1 22 Example 1 11CONNECTI1D2340567B01 Indicates a connection for Port 1 with destination address 234 and origination address 567 and using B channel 1 Example 2 11CONNECTI1D2340567B01S01 ATB45 only Indicates a speech connection for Port 1 with destination address 234 and origination address 567 and using B channel 1 CRA I lt Call Reference gt B lt hb gt outgoing call accepted This CRA response to an outgoing call initiated by a CR that the call will be processed SETUP ACK or CALL PROCEEDING from the ISDN line The ongoing connection can be referenced by the Call Reference Tones on the ISDN B channel
69. igurator by the command quit Note After altering one of the profile values marked by 7 you have to give the additional commands save and go This is necessary to save and activate these new parameters 62 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set 4 3 Configuring the TA POX after power on For this entry you have to set the configuration parameter rstmsg 1 e Connect the TA POX to ISDN interface e Connect the PC s com port to the DTE interface of the TA POX e Start a terminal emulation program i e Hyper Terminal with the following settings 9600 Baud 8 databits No Parity 8N1 e Connect the TA POX to the mains by the mains plug adaptor e Wait until LED 2 starts blinking after about 5 sec see config cmd start and the message to enter the config sequence is displayed Press lt CR gt lt CR gt lt ESC gt lt ESC gt to enter TA Configurator e Type in quickly the sequence lt RET gt lt RET gt lt ESC gt lt ESCs to call up the TA Configurator e The TA Configurator acknowledges by giving a welcome string and a as the prompt character Now you can work with the TA Configurator by using the configuration commands see page 66 e Setup the parameter for the TA POX from your terminal program and store them Example To change the used B channel protocol to X 75 please enter the following comman
70. in the ISDN B channel loop which can configure with parameter bch1idelay ATS70 lt 0 1 gt IOM2 port command prefix for ATB40 43 45 only This parameter manage the command prefix for the IOM2 interface TA HUX TA SOC or codec port TA HIX on the TA hardware of the serial data output or 1 Depending of the value in ATS70 the incoming call will message e an IOM2 interface call RINGIxDxxxOxxxBOx e ora CODEC interface call 1 RINGIxDxxxOxxxBOx TA HIX only ATS70 0 incoming call will be displayed as IOM2 calls default Example RINGI1D2110222B01 ATS70 1 incoming call will be displayed as CODEC calls and enable the CODEC Example 1RINGI1D2110222B01 When the command interface receive an ext IOM command AT xxx or an CODEC command AT 1xxx the value for the data structure will be changed in this S register will be changed automatically Stollmann Entwicklungs und Vertriebs GmbH 35 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX ATS71 lt 0 1 gt Codec port command behaviour for TA HIX only This parameter manage the response of voice commands according to the older product called TA HIT ATS71 0 voice connections are controlled as described in the current manual of TA HIX default ATS71 1 voice connections are controlled as described in the manual of TA HIT 80 RING message interval time S80 controls the time interval in 100ms st
71. inal Ready 41 X4 GND GND Signal 61 X5 VCC 3 3V Power Supply 62 _ X5 nc 63 X5 GND GND Supply 64 X5 nc nc not connected do not connect to any signal 112 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 6 Appendix A9 TA POX Pinout of the ISDN connector Pinout of the 8 pin ISDN S interface connector RJ45 ITU 1 430 ISO 8877 Pin Signal Sbus ___ Rx Receive Tx Transmit Not connected Not connected A10 TA POX Pinout of the V 24 V 28 interface DSUB 9 DSUB Pin Signal Signal Signal Direction Comment ITU DIN EIA 1 109 M5 DCD O Data Carrier Detect 2 104 D2 RxD O Receive Data 3 103 D1 TxD l Transmit Data 4 108 1 S1 1 DTR Data Terminal 108 2 1 2 Ready 5 102 E2 GND Signal Ground 6 107 M1 DSR O Data Set Ready 7 105 S2 RTS l Request To Send 8 106 M2 CTS O Clear To Send 9 125 M3 RI O Ring Indicator Stollmann Entwicklungs und Vertriebs GmbH 113 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 6 Appendix A11 TA POX Cable layout for connection of terminals with 25 pin connectors male or female Only the cable with a male plug at the terminal side is shown The pin configuration for the female plug is the same V 24 device TA POX 1 shield 2 TD 103 3 3 RD 104 2 4 RTS 105 7 5 CTS 106 8 6 DSR 107 6 20 DTR 1
72. ine character was sent The timer is started after each received command line character from the serial interface When no Carriage Return character i e 0x0D was received after the timer expired the complete command line parameter list is erased The default value is set to 30 seconds This timer is available in the command mode only S30 Suppress sending the Escape Sequence S30 controls the behaviour of transmitting the Escape Sequence Character ATS2 as a data stream to the destination side ATS30 0 Escape characters will not be sent ATS30 1 Escape characters will be sent default 34 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 31 B channel loop for analysis only option 31 activate a loop of the B channel for incoming calls during the active connection The used B channel for the loop is given from the public switch within the incoming call message DSS1 SETUP l element Channel Identification 0x18 ATS31 0 ISDN B channel loop deactivated default ATS31 1 ISDN B channel loop activated The value of ATS31 register is saved into the internal configuration parameter bchloop Note The configured B channel protocol must be set to ATB5 Byte transparent To accept different call types data calls and speech calls you can configure this behavior with parameter AT C2 Note Please also check the delay with
73. invalid for state p6 1A X Packet type invalid for state p7 1B X Packet type invalid for state d1 1C X Packet type invalid for state d2 1D Packet type invalid for state d3 20 Packet not allowed 21 X PVC Unidentifiable packet 22 X Call on one way logical channel 23 PVC Packet type invalid for state at PVC 24 X Packet on unassigned logical channel 25 X Reject not subscribed to 26 X X X Packet too short 27 X X X Packet too long 28 X X Invalid general format identifier 29 X X X Restart or registration packet 0 2A X Packet type not compatible with facility 2B X Unauthorized interrupt conformation 2C X Unauthorized interrupt 2C X Unauthorized reject 30 Time expired 31 X for incoming call 32 X For clear indication 33 X PVC For reset indication 34 X X For restart indication 35 X X For call deflection 40 Call set up call clearing or registration problem 94 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 5 Diagnostic and error messages 41 X Facility registration code not allowed 42 X Facility parameter not allowed 43 X Invalid called DTE address 44 X X Invalid calling DTE address 45 X Invalid facility registration length 46 X Incoming call barred 47 X No logical channel available 48 X
74. is the CIP value as defined in the CAPI 2 0 specification also to be found via Stollmann URL http www stollmann de AT C 20 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX C1 hbhb Select bearer service outgoing Selects the bearer service that will be sent with an outgoing call The value for hbhb word is the CIP value as defined in the CAPI 2 0 specification default 0000 Example an outgoing call as a voice call AT C1 0004 Example an outgoing call as a data call AT C1 0002 C2 hbhbhbhb Select bearer service incoming Selects the bearer services that can be accepted with an incoming call The definition of hbhbhbhb double word is the CIP mask as defined in the CAPI 2 0 specification default 00000004 Example AT C2 00030012 Accept analogue incoming calls AT C2 00000001 Accept all incoming calls Note Before issuing an outgoing call the command AT C1 has to be set To use the predefined services please setup factory defaults AT amp F D Initiate outgoing call Dials the number D for Dial The dial modifier W gt T can be freely inserted in the dial string they have no influence on the dial procedure of the TA POX TA HUX Must be the last command in AT command line Any character input while the TA is dialing will cancel the dialing procedure 1 ATD lt CALLEDnumbers X Pxxx R N lt nuipwd gt
75. is valid from the indication of an incomig call or the status change of an connect request til the given release command Example AT A 11 Accept an incoming call for port 1 48 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX AT CC I lt Call Reference gt Dern gt Send destination address to the network Continue to send the destination address to the network overlap dialling after initiating an outgoing call i e command AT CR without complete destination address I selects Call Reference 1 9 D sets destination address the dialing number K sets Keypad information option currently not implemented lt rn gt ISDN number string of digits 1 22 Example AT CC l1 D12345 Continue for an existing ougoing call for port 1 to send the destination address 12345 to the network AT CR Dern gt O lt rn gt Connect Request to the network AT CR Dern gt O lt rn gt S lt nn gt ATB45 only Initiate an outgoing call D sets destination address the dialing number O sets origination address own msn optional S sets the service indicator available values 01 02 04 16 01 speech 02 unrestricted digital information 04 3 1kHz audio 16 telephony lt rn gt ISDN number string of digits 1 22 The TA module initiates an outgoing call request and reports the call reference With p
76. k of the TA POX you will find the connectors for the following interfaces Fig 2 Back view of the desktop model TA POX PWR external power supply 5V DC ISDN ISDN interface DTE V 24 interface for DTE i e a PC Stollmann Entwicklungs und Vertriebs GmbH 5 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 3 Using the TA POX TA HUX TA SOC You can select different operation modes for the TA POX These operating modes are used to setup ISDN connections and to configure the TA POX Supported operating modes e X 3 asynchronous mode to connect asynchronous devices that drive a PAD X 3 interface e asynchronous mode for devices that need the AT command set e Automatic dialing deriving from DTR or TxD or always connected You can configure the TA POxX in the following ways e by using the X 3 command set entered by the locally connected PC e by using the AT command set entered by the locally connected PC e by using TA configuration commands entered by the locally connected PC e by using TA configuration commands entered via the ISDN line remote configuration 6 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 3 1 X 3 command set integrated PAD If you connect an asynchronous DTE to the X 31 service you can use the integrated PAD of the TA POX You can use for example the command stat to see the status of the co
77. l CTS off the TA will buffer up to 256 bytes from the DTE device e f the connection will be cleared with DTR off during an active flow control CTS off the current connection will be cleared after a short timeout The received serial data from the DTE during the connection will be erased after clearing the connection The control lines to indicate the active connection DCD and the off hook state DSR will be changed without recognizing the current flow control state RI Ring indicator The serial status line RI gets active during an incoming call request If the incoming call will be accepted or the call request ended the RI control circuit gets off 42 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 3 4 Automatic call establishment Automatic call establishment is available in the following modes e An automatic call will be initiated when the control line DTR is on e An automatic call will be initiated when serial transmit data character received into the terminal adapter e Automatic connection establishment independent of any status line To enable automatic call you have to set TA configuration parameter cmds to 6 7 rsp 8 see below With changing this parameter the baudrate has be set to a fixed value br not equal to 0 An established connection will be indicated by a status line See also configurations commands cdcd and cdtr I
78. lready received serial data will be transmitted to the ISDN using the selected transmission protocol comparable to the functionality of X 29 parameter 4 data forwarding timer 0 minimum delay time app 10 ms 1 n delay time in 10 ms ticks default 0 10 ms Note Valid for AT command set and X 75 X 25 B channel or X 25 D channel only ver show version string Displays detailed information about the software version and TA type 84 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set verb show version string of bootloader Displays detailed information about the bootloader version v110llc Usage of LLC for V 110 connections Set LLC parameter for incoming and outgoing V 110 connections 0 LLC is ignored and not created 1 outgoing call an LLC is sent deriving from the settings of the TA incoming call the received LLC is used to setup the parameters for the V 110 connection default v110flc Usage of V 110 flowcontrol Controls the ISDN flowcontrol for V 110 connections 0 V 110 flowcontrol via xbits will be ignored default 1 V 110 flowcontrol via xbits enabled Ww B channel windowsize L3 B channel layer 3 protocol windowsize default 2 w 1 7 Value will be automatically changed with changing B channel protocol prot xnr own X 25 address Setup an origination X 25 address xnr nn set
79. lue 0xF01 3841 msni Multiple Subscriber Number for incoming calls Own MSN Multiple Subscriber Number for incoming calls msni global msn all incoming calls will be accepted msni nn set msni to nn string of digits max length 20 msni no acceptance of incoming calls msni show current setting of msni msno Multiple Subscriber Number for outgoing calls Own MSN Multiple Subscriber Number for outgoing calls msno no msn value will be used for outgoing calls msno nn set msno to nn string of digits max length 20 msno show current setting of msno Stollmann Entwicklungs und Vertriebs GmbH 77 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set pxxx X3 parameter set PAD X 3 command set only show setting of one X3 parameter Change X3 parameter by entering the new value p001 show setting of X3 parameter 0 p001 1 set X3 parameter 0 to 1 Note See chapter 3 1 1 for supported pad parameter pnp plug and play ID Select the plug and play functionality for WINDOWS operating systems 0 disable plug and play ID 1 enable plug and play ID prot B channel protocol Transmission protocol for data transfer 0 V 110 asynchronous 3 HDLC async to sync conversion PPP asynchronous 4 HDLC transparent octets are packed into HDLC frames 5 Byte transparent voice connection raw B channel data 6 Byte transparent data connection raw B c
80. mand set ftei tei value point to point fixed tei Reserved functionality Point to Point mode only Value of the terminal equipment identifier for fixed tei connections This value is set to 0 per default and should not be changed 0 63 tei value as defined will be used default 0 127 automatic tei procedure will be used Note changing the type of ISDN access by setting the parameter ptp will automatically change the parameter ftei These values get active after sending save command and a reset of the TA fwload load new firmware 8Mbit Flash memory required option This commands loads new firmware into the TA without starting The firmware will be stored into the upper not used part of the flash memory While uploading the following checks will be performed File transfer protocol is XMODEM1K An overall firmware checksum is used The firmware type written in the module header of the firmware must be compatible to the hardware and allowed firmware type stored inside the Bootloader NOTE If the flash memory size is only 4Mbit this command is not supported fwstart start new firmware 8Mbit Flash memory required option This command starts new firmware previously stored within the TA The firmware stored in the upper part of the flash memory will be loaded into the executable part of the FlashProm and started if the following conditions are met the overall firmware checksum must be correct
81. message includes the cause of the last connection attempt In case the disconnect is caused by elapsing of the timer shto the cause No User Responding is indicated to the application n 0 default 2 show show parameters Displays the actual set of parameters showall show all parameters Displays the all accessible parameters spid1 spid2 set spid option For ISDN lines in the U S you have to set the SPID You get it from your ISDN provider spid1 xxx Set SPID 1 spid2 xxx Set SPID 2 Stollmann Entwicklungs und Vertriebs GmbH 83 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set status Global status of TA The overall status of the TA will be displayed Example Current status information TA POX serial line DTR on RTS on DSR on CTS on DCD on RI off ISDN L1 up Dch Prot DSS1 State connected CdPN 291 CgPN 509 prev error 0 Bch Prot X 75 SLP State connected CdPN 291 CgPN 509 tei TEI value X 31 D channel only Terminal equipment identifier This value must be identical to the tei of your basic rate access will be defined by your ISDN supplier tei 1 default trennn commands for internal trace The usage of the commands for internal trace are described in chapter 5 6 txfwd timer for data forwarding If no additional character to the already entered characters is entered within the defined period the a
82. n automatic establishment of a B channel connection can be selected if the X 25 call using the X 31 D channel is not successful The B channel connection will be started if e no successful X 25 connection is established within of a timeout set by command cato in seconds e anerror is reported from X 31 D channel line The rerouting will be activated by setting the configuration command x31rr 1 from PAD enter please exec x31rr 1 The ISDN number used for establishment of the B channel connection will be taken from the table xtab dependent of the entry found in the table If the X 25 address meets no entry the rerouting will not be used Example 1 To enable rerouting for all X25 addresses x31rr 1 xtab1 i04089928392 2 To enable rerouting for the x25 address 45400012345 and 45400012389 x31rr 1 xtab1 45400012345i104089928392 xtab2 45400012389i104089928392 or xtab1 454000123 i04089928392 or xtab1 454000123 7104089928392 44 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 3 6 Using Multilink PPP option To enable Multilink PPP handling within the TA please enable protocol ML PPP ATB31 rsp prot 31 ML PPP may be used with two different authentication protocols during the link establishment phase e PAP password authentication protocol RFC 1334 e CHAP challenge handshake authentication protocol RFC 1994 with variants e MD5 according
83. nd RTS will be controlled of an interrupt in the TA firmware With regard of this behave the maximum input level change must be lower than 100Hz 10ms steps The V 24 control circuits will be described for the three different states no connect phase The TA has no ISDN connection The serial data commands and responses will be used to configure the TA command mode dial phase The TA has started to establish an ISDN connection and is and waiting for the synchronization disconnect phase The TA disconnects the existing connection B channel and D channel connection ISDN data connection is established D channel and B channel connected Serial data will be sent or received according to the configured B channel protocol data mode connect phase Status line Description no connect dial disc connect CTS 0 CTS follows RTS RTS flc _ RTS flc ERTS flc 1 HW FLC ON flc ON flc ON flc 2 CTS follows DTR DTR flc _ DTR flc EDTR flc DCD 0 DCD always ON ON ON ON 1 DCD indicates a connection OFF OFF ON 2 DCD follows DTR DTR DTR DTR DSR 0 DSR always ON ON ON ON 1 DSR indicates a connection OFF OFF ON 2 DSR follows DTR DTR DTR DTR 3 DSR follows DCD DCD DCD DCD 5 DSR Off Hook OFF ON ON connection establishment started flc CTS signals the serial flow control from TA DCE to the DTE in the command mode and data mode flc 5
84. nes are indicated by an gt Coding of trace data bytes dependent of TypeAndSource The high order bit shows always the direction of the data Oxxx received data into the TA from ISDN or serial 8xxx transmitted data by the TA to ISDN or serial 102 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 5 Diagnostic and error messages 0511 8511 D channel layer 1 status OxF1 Inactive not used OxF2 Sensing not used Ox F3 Deactivate Ox F4 Awaiting Signal Ox F5 Indentifying Input 0x F6 Synchronized 0x F7 Activated 0x F8 Lost Framing 0512 D channel layer 1 C I code NT to TE 0x00 Deactivation Request from F7 F8 0x01 Reset acknowlegde 0x02 Test mode acknowlegde 0x03 Slip detected 0x04 Signal received 0x05 Deactivation Request from F6 0x07 Power up 0x08 Activation request Ox0A Activation request loop 0x0B Illegal code violation Ox0C Activation indication priority 8 Ox0OD Activation indication priority 10 OxOE Activation indication loop OxOF Deactivation confirmation 8512 D channel layer 1 C I code TE to NT 0x00 Timing 0x01 Reset 0x02 Test mode SSP 0x03 Test mode SCP 0x08 Activation request priority 8 0x09 Activation request priority 10 Ox0A Activation request loop OxOF Deactivation indication 0712 8712 D channel messages coding refers to Q 931 and ETS 300102 1 Coding of Message Type within D channel layer 3 message 4 data byte in trace output St
85. network for the call that is addressed by Call Reference This command is only requred when the terminal adpter does not automatically send the ALERT message to the ISDN public switch To suppress sending the ALERT message you have to modify the value ATS80 0 default ATS80 50 RING message timer in 100ms steps The ALERT message has to be sent within 8 seconds after receiving the inconing call message RING Example AT RAI Initiate an alert request for an existing incoming call for port 1 Note After sending this AT RAI1 command no additional RING message will be sent from the ISDN TA to the serial interface Stollmann Entwicklungs und Vertriebs GmbH 51 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX AT REL I lt Call Reference gt Disconnects existing ISDN connection with the cause value 3490 normal call clearing to the public switch The Call Reference is released by this command and is no longer valid Example AT REL 11 Disconnect an existing connection with normal call clearing AT TS lt Call ldentifier gt B lt Channel gt T lt Timeslot gt Select IOM 2 Timeslot Selects a Timeslot for the B Channel Example AT TS 11 B2 T2 Select I OM Timslot 2 for B channel 2 for call 1 52 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX 3 7 2 AT result messages All messages sent from t
86. ng to S12 register gt 2 lt gt lt gt lt gt 3 lt delay time according to S12 register gt The time gap between all three plus signs may not exceed 1 sec The escape sequence is transmitted transparent to the remote device The timeout after sending the escape sequence lt gt lt gt lt gt will increase if the configuration parameter txfwd will rise The default value of txfwd is set to 0 l Display version information Displays different information about version number and settings ATI Returns the Modem type name of the terminal adapter TA POX ATI1 Returns internal checksum 0 ATI2 Returns OK ATI3 Returns version string V7 xyz ATI4 Returns manufacturers name Stollmann E V GmbH ATI5 Returns ISDN selected protocol 0 DSS1 ATI6 Returns copyright string c Copyright Stollmann GmbH ATI7 Returns OK ATI8 Returns ERROR ATI9 Returns plug and play ID string ATI77 Returns Bootloader version string ATI99 Returns software creation date 24 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX amp K Flow control Selects the flow control behavior of the TA while in data communication phase AT amp K No local flow control between the DTE and TA is used AT amp K3 Local flow control is set to hardware handshake RTS CTS AT amp K5 Hardware flowcontrol RTS CTS in data mode and command mode F
87. nges of RTS AT amp R1 CTS is ON and handle serial flow control RTS CTS default AT amp R2 TA control line CTS is following all changes of DTR For nearer information see also chapter 3 3 S Display and set internal S register ATSnn Show actual values decimal of selected register nn ATSnn xxx Set selected register nn to the decimal value xxx For nearer information see also chapter 3 2 1 AT command S register set amp S DSR control Selects the behavior of the DSR control line from the TA AT amp S TA control line DSR is always ON default AT amp S1 DSR ON indicates ISDN connection is established and synchronized AT amp S2 TA control line DSR is following all changes of DTR AT amp S3 TA control line DSR is following all changes of DCD AT amp S5 DSR ON indicates an active ISDN call procedure off hook For nearer information see also chapter 3 3 V Result format ATV Result is presented as numbers followed by lt gt ATV1 Result is presented as text default 26 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX amp V Display configuration AT amp V Displays the actual configuration of AT command setting including stored ISDN numbers AT amp V1 Displays the actual configuration of extended AT command setting Ww Extended result codes ATW ATW1 1 Result is presented without extended result codes 2 Result is pre
88. nnection To setup PAD mode please use the configuration command cmds 1 The following PAD Commands regarding the specifications X 28 X 29 are supported dot Displays PAD identification Pxxx R N lt nuipwd gt G lt cug gt X25number lt SDNnumber gt D lt userdata gt Establishes an X 25 connection select X 25 packet size xxx for X 25 connection request the facility reverse charging access to X 25 closed user group Outgoing call from X 25 closed user group use NUI and password with call setup allowed chars a z A Z 0 9 overrides setting of nui configuration command X25number dialed X 25 call number SDNnumber ISDN call number for a dialed B channel connection D separator for user data D P or ZOOQOVNU clr Clears an X 25 connection stat Showing the PAD connection status set Set the PAD Profile to Profile 0 set x n Set the PAD Profile parameter x to value n Note PAD parameter can be stored using the command exec save prof x Configures to the PAD Profile x x 0 7 90 91 Note PAD parameter can be stored using the command exec save prof Displays the configured PAD Profile values par x x Displays all configured PAD Profile values or the PAD parameter x par without parameter displays all parameter ver Displays the version number Stollmann Entwicklungs und Vertriebs GmbH 7 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3
89. nowledges by requesting the remote password Please enter the correct password default no password just return Now you can work with the TA Configurator by using the TA Configurator commands see page 61 Configure the parameter for the remote TA POX from your terminal program and store them if wanted see page 66 Example To change the used B channel protocol to X 75 please enter the following commands prot 10 lt gt set protocol to X 75 blocksize 2048 save lt I gt save the new configuration Hint The active set of parameters can be displayed on screen by the TA Configurator with the command show lt gt If necessary the remote TA POX can be reset using the command reset lt t gt Hang up the ISDN connection by leaving the TA Configurator using the command quit Leave your terminal program After the next reset the changes will be active Now the configured remote TA POX with the new set of parameters can be used by running the needed PC program 64 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set 4 4 1 Remote access control Using the following commands you can setup a table to allow only dedicated callers to get a connection to the remote management facilities inside the TA If this list is empty default or one entry with a star is set any incoming call is allowed Every incoming call that does not fit t
90. o one of the entries of acctab will be rejected with the ISDN cause call rejected racctabx nn set entry number x to ISDN number nn racctabx clear entry number x racctabx Allow all incoming calls to be accepted racctabx Show entry number x racctab Show all entries Maximum number of entries 5 Maximum length of ISDN number 20 digits The ISDN number can contain wildcards represents one or more digits represents exactly one digits Example racctab1 1234567890 accept the only specified number racctab2 456 accept all number with 456 somewhere in the middle racctab3 2345678 accept all number with 2345678 in the middle preceded by one digit and followed by two digits racctab3 accept all incoming calls racctab3 clear entry no 3 Stollmann Entwicklungs und Vertriebs GmbH 65 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set 4 5 List of TA Configurator commands The TA Configurator commands typed in must have the correct syntax and be complete including all blanks Capital small letter use is not important The entry is not case sensitive The bolded values are factory defaults The usage is lt command gt parameter Example to set the ISDN B channel protocol to X 75 prot 10 Example to show the selected ISDN protocol prot Example to show all selectable ISDN protocols prot To get an overview about the commands of your TA some major comm
91. ollmann Entwicklungs und Vertriebs GmbH 103 TA HIX TA HUX TA POX TA SOC User manual 5 Diagnostic and error messages r01 06 2009 104 Message Message name code Hex 2 5 5 0 0602 8602 D channel LAP D frames coding refers to Q 921 0904 8904 Serial line received transmitted data by the TA in command phase i e AT commands and responses Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 5 Diagnostic and error messages 0901 Serial status lines X X CTS RTS DCD RI DSR DTR O 1 O 1 0 1 0 1 0 1 0 1 The count of the received value is hexadecimal coded 0x NN An active level ON of the serial status line is signaled with logical level 1 Example DTR Hex coded result OxNN Stollmann Entwicklungs und Vertriebs GmbH 105 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 6 Appendix 6 Appendix A1 Technical data TA POX TA HUX TA SOC TA POX serial interface functional electrical mechanical TA HUX serial interface functional electrical mechanical TA SOC serial interface functional electrical mechanical Transmission speeds DTE B channel Character representation Character synchronization Operating mode ISDN interface TA POX mechanical TA HUX mechanical TA SOC mechanical
92. on Send the escape sequence delay of 1 second ATH lt cr gt or drop the serial status line DTR OFF Note There is currently no connection control between both devices from end to end If one device will be removed from the leased line the other device is still connected Stollmann Entwicklungs und Vertriebs GmbH 59 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX 3 8 1 2 ISDN connection with automatic call establishment Automatic call establishment is available in the following modes An automatic call will be initiated when the control line DTR is on An automatic call will be initiated when serial transmit data character received into the terminal adapter Automatic connection establishment independent of any status line To enable automatic call you have to set TA configuration parameter cmds to 6 7 rsp 8 see below With changing this parameter the baudrate has be set to a fixed value br not equal to 0 An established connection will be indicated by a status line See also configurations commands cdcd and cdtr If a connection cannot be established successfully an automatic retry will be started The duration of trying to establish the connection and the pause for next retry can be configured The dialed number is taken from the parameter catab1 cmds 6 Automatic connection establishment when DTR is ON cmds 7 Automatic connection establishment when the TA
93. or nearer information see also chapter 3 3 M Received CLID Shows the called line identification CLID that is received with an incoming call this is the number of the called party addressed on the local S bus selected msn AT M N Set line baudrate V 110 Selects the line baudrate of the TA to the desired value only valid for B channel protocol V 110 asynchronous ATNO Line baudrate automatic set equals to local baudrate or less ATN1 Line baudrate set to 1200 bit s ATN2 Line baudrate set to 2400 bit s ATNS Line baudrate set to 4800 bit s ATN4 Line baudrate set to 9600 bit s ATN5 Line baudrate set to 19200 bit s O Return to online state If the TA POX is in command mode after issuing an escape sequence out of an existing connection ATO brings the TA POX back to data phase Must be the last command in AT command line ATO O Received CLIP Shows the calling line identification CLIP that is received with an incoming call number of the calling party AT O Stollmann Entwicklungs und Vertriebs GmbH 25 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX Q Suppress results With this command result codes or messages can be suppressed ATQ Returns status codes after command input default ATQ1 No result codes are returned amp R CTS control Selects the behavior of the CTS control line from the TA AT amp R TA control line CTS is following all cha
94. parent data connection raw B channel data ATB10 X 75 SLP ATB13 V 120 async ATB20 X 31 B channel X 25 B channel ATB21 X 31 D channel ATB22 T 70NL ATB23 T 90NL ATB31 MLPPP Option ATB33 X 75 B channel bundling Option For this type of protocol both B channel on the ISDN interface need to be free Otherwise the connection will fail no automatic detection ATB40 B channel transp switched to IOM 2 audio connection ATB43 B channel transp switched to IOM 2 data connection ATB45 B channel transp switched to IOM 2 data and audio connection B Set local baudrate Sets the local baudrate of the TA to the desired value fix value or to auto detection When auto detection is set the TA will recognize the desired baudrate with every newly entered AT command by the terminal equipment PC With all other settings the PC must use the same baudrate Must be the last command in an AT command line AT BO Automatic local baudrate detection enabled default autobauding exclude serial speed of 300bps 600bps 10400bps AT B1 Local baudrate set to 1200 bit s AT B2 Local baudrate set to 2400 bit s AT B3 Local baudrate set to 4800 bit s AT B4 Local baudrate set to 9600 bit s AT B5 Local baudrate set to 19200 bit s AT B6 Local baudrate set to 38400 bit s AT B7 Local baudrate set to 57600 bit s AT B8 Local baudrate set to 115200 bit s AT B9 Local baudrate set to 230400 bit s Stollmann Entwicklung
95. r can be set from 1 to 16 LCN bit 1 to bit 4 LCN values from 17 to 256 LCN bit 5 to 8 are currently not supported These LCN values will fail within the outgoing call with the result code NO DIALTONE Explanation of X 25 channel number structure Logical channel group number Logical channel number LCGN 4 bit length bit 9 to 12 LCN 8 bit length bit 1 to 8 XX XX 0000 XXX X Example LCGN 0 and LCN 1 ditc value 0x001 1 LCGN 0 and LCN 5 ditc value 0x005 5 LCGN 2 and LCN 10 ditc value 0x20A 522 LCGN 4 and LCN 1 ditc value 0x401 1025 LCGN 15 and LCN 1 ditc value OxF01 3841 dte B channel link address Selects the Layer 2 link addresses for ISDN B channel Only valid for protocols that are HDLC based X 75 LAPB X 25 B 0 Calling side reacts as DTE called side reacts as DCE default for several protocols prot 10 13 22 23 1 TA reacts as DTE own adr 01 default for X 25 protocol prot 20 21 3 TA reacts as DCE own adr 03 Note The value will be changed by setting the B channel protocol prot flc flowcontrol Flowcontrol to DTE 0 No flowcontrol 3 Hardware flowcontrol RTS CTS in the data mode 5 Hardware flowcontrol RTS CTS in data mode and command mode For nearer information see also chapter 3 2 Stollmann Entwicklungs und Vertriebs GmbH 73 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator com
96. rd corresponding to the user name used for the PPP connection If the server does not handle CHAP an automatic fallback to PAP is performed chappwd lt password gt set password for CHAP Note Since the password is shown in plain text it may be disclosed by unauthorized persons cmds command set note 1 Command set for connection control 0 AT command set default 1 PAD X 3 command set 6 Automatic dialing when DTR is set 7 Automatic dialing when TxD is received by the TA 8 Automatic dialing always connect 10 Configurator internal configuration command set 12 incoming calls only no active connections Note For details see the appropriate chapters After changing cmds via remote management the TA has to be reset using the command reset cnr lt x gt storing phone numbers The TA POX can store up to three of the most frequently called numbers AT amp Z1 AT amp Z2 AT amp Z3 These parameter can also be set from the internal configurator cnrx nn set entry number x to SDNnumber nn max length 20 digits cnrx shows the value of entry x cnrx clears the value of entry x See also parameter AT amp Z lt x gt lt nnn gt Stollmann Entwicklungs und Vertriebs GmbH 71 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set dbits asynchronous databits Number of data bits asynchronous chars default 8 7 8 Note To use other data formats than 10 bit N1 7E1
97. receives any data byte cmds 8 Automatic connection establishment independent of any status line Note autobauding is not supported set br not equal to 0 cato n call abort of a not successful call after n seconds n 3 255 default 15 seconds capan call pause for n seconds before next call attempt n 0 immediate call retry n 0 255 default 3 seconds catab1 nn set ISDN number nn catab1 clear entry catab1 show entry Maximum length of ISDN number 20 digits Hint The configuration command idle can be used to automatically disconnect after a predefined time without data transmission Note Please take care that parameter rsttim is greater than 10 and rstmsg 1 to enable the entry into the TA Configurator after reset default 40 4 sec 60 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set 4 TA Configurator command set The settings of the TA POX for the serial interface and the S bus interface are called configuration The TA POX is delivered with a set of pre set values In the following section it will be shown how by using the configuration commands you can examine the configuration of the TA POX and if necessary change it The values can be stored in non volatile memory this means they ll remain unchanged even if the power supply is disconnected You can configure the TA POxX in the following ways e by using T
98. remote management to get a connection to the TA racctabx nn set entry number x to ISDN number nn racctabx clear entry number x racctabx Allow all incoming calls to be accepted racctabx show entry number x racctab Show all entries Note for a detailed description see chapter 4 4 1 reset reset TA POX Resets the whole functionality of the TA POX by a forced hardware reset like Power off on Refer also to parameter rsttim Note If you reset a TA from remote management the resetted TA will loose it s connection to the ISDN network Due to timeouts of the ISDN network it can take up to 30 seconds till the local TA will notify the released connection Stollmann Entwicklungs und Vertriebs GmbH 79 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set ridle idle data timeout for remote connection Timer to disconnect the remote connection after inactivity sec 0 inactive 1 n delay time to disconnect in seconds 1 255 60 60 seconds default rmua rmua1 rmua2 rmua3 Output pin behavior Definition of the behavior of the output pins UA UA1 UA2 and UAS3 The behavior can be configured by using one of the following setting to the value of the list below The output level can be inverted by adding 128 to the desired value defines the output pin to low active 0 output pin always OFF 1 output pin always ON 2 ISDN activation blinking 0 5 sec OFF 0 5 sec
99. rol commands describe within this document support the following supplementary services for ISDN connections CLIP MSN Overlap dialling Call waiting Call hold Call retrieve 3 party conference 3 7 1 ext IOM 2 interface command set The following section describes the enhancements for driving B channel connections without switching the B channel to an on board device Codec The B channel data have to be interfaced through the IOM interface To select the IOM2 interface of the TA HUX or TA SOC module you have to select the correct B channel protocol ATB40 external IOM2 audio connections speech S01 used see command CR ATB43 external IOM2 data connections speech S02 used see command CR ATB45 external OM2 audio data connections Service user defined Every command is always answered by the ISDN module a following command may only be entered after a response has been received Every AT command that controlles a B channel connection without switching an on board device to the B channel is preceeded by a and a dummy port number always Example AT CR D1234 Establish a connection Result messages to the commands are preceeded by Example CONNECT Connection established Stollmann Entwicklungs und Vertriebs GmbH 47 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX Every B channel connection is identified by a call reference Call Referenc
100. rotocol set to B40 the service indicator 01 speech will be used Result message SCRAI lt Call Reference gt B lt selected B channel gt B channel selection first B channel B01 second B channel B02 Example 1 Command AT CR D234 0567 Result CRAI1B01 Intiate an outgoing call for port 1 with destination address 234 and origination address 567 own msn the call can be referenced using the call reference 1 The used B channel is reported in the result message Stollmann Entwicklungs und Vertriebs GmbH 49 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX Example 2 Command AT CR D234 0567 S02 ATB45 only Result CRAI1B01 Intiate an outgoing data call for port 1 with destination address 234 and origination address 567 own msn the call can be referenced using the call reference 1 The used B channel is reported in the result message AT CH I lt Call Reference gt Call Hold option Hold the call which is addressed by Call Reference Example AT CH 11 Intiate a call hold for the existing connection 1 for Port 1 AT CA I lt Call Reference gt Call Retrieve option Retrieve the call which is addressed by Call Reference Example AT CA l1 Intiate retrieve for the existing connection 1 for Port 1 AT C3PTY I lt Call Reference gt IH lt Call Reference HeldCall gt option Pass into three party service Pass into three party which is addressed by the call reference
101. s und Vertriebs GmbH 19 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX AT B20 Local baudrate set to 300 bit s no autobauding detection AT B21 Local baudrate set to 600 bit s no autobauding detection AT B26 Local baudrate set to 10400 bit s no autobauding detection Note If autobauding AT BO is selected default after switching on the TA POX and no local AT command is entered the incoming call message i e RING will be sent with 115200 bit s The automatic local baudrate detection autobauding will also support the local data format detection for 10 bit character format 7 E 1 7 0 1 8 N 1 CONF Enter TA Configurator Enters directly into the TA Configurator the configuration prompt will be displayed Leave the TA Configurator with the command quit or exit or go ATCONF Note During the change between the command sets from AT command set to configuration command set the serial status line DSR gets inactive amp C DCD control Selects the behavior of the DCD control line from the TA AT amp C TA control line DCD is always ON AT amp C1 DCD ON indicates ISDN connection is established and synchronized default AT amp C2 TA control line DCD follows DTR For nearer information see also chapter 3 3 C Received bearer service Shows the bearer service that is received with an incoming call in hexadecimal coding hbhb The value for hbhb word
102. s our appreciation This documentation is valid for the products TA HIX TA HUX TA POX TA SOC hardware version 2 Software versions V7 000 or later Please refer to the appendixes about differences between the products 1 1 Product description The TA POX is an ISDN terminal adapter with the following functions You can see it as a digital replacement for an analogue modem e The TA POX connects devices with a serial port to the ISDN It gives access to other devices connected to the ISDN network e Data can be transmitted either over the D or B channel with the following rates by using the transmission method V 110 or V 120 in B channel by using the transmission method X 75 PPP or HDLC in B channel calla host connected to the X 25 network X 25 in B or D channel calla host connected to an ISDN X 31 subscriber line e Data can be transmitted either over the D or B channel with the following rates Transmission via D channel with 9600 bps X 31 D Transmission via B channel with 64000 bps X 31 B e The connected device can drive the TA POX by using asynchronous PAD X 3 commands asynchronous AT commands automatic call To work with TA POX you need e an ISDN Basic Rate Interface BRI replacing an analogue telephone line The basic rate access can be ordered by your local telephone company or PTT e a PC with a terminal emulation to configure the TA POX Stollmann Entwicklungs und Vertriebs GmbH 1 TA H
103. se 4 ERROR Illegal command or error that can not be indicated otherwise 5 CONNECT 1200 lt m gt Connection line speed 1 2 kbps V 110 6 NO DIALTONE lt xx gt No access to ISDN network xx ISDN error 7 BUSY lt xx gt Number engaged xx ISDN error cause 8 NO ANSWER lt xx gt No connection called number can not be reached xx ISDN error cause 10 CONNECT 2400 lt rn gt Connection line speed 2 4 kbps V 110 11 CONNECT 4800 lt rn gt Connection line speed 4 8 kbps V 110 12 CONNECT 9600 lt rn gt Connection line speed 9 6 kbps V 110 16 CONNECT 19200 lt rn gt Connection line speed 19 2 kbps V 110 17 CONNECT 38400 lt rn gt _ Connection line speed 38 4 kbps V 110 19 CONNECT 64000 lt rn gt __ Connection line speed 64 kbps Call number display lt rn gt call number of remote site In AT command mode call number display does not belong to the standard AT command set can be turned on by issuing the command ATW1 If turned on the call number of the caller is shown with the CONNECT or RING message in pointed brackets depending on the signaling in the D channel If the TA is used at the public network then the call number of the remote site including area code is displayed Example TxD RxD ATW1 OK RING lt 040890880 gt ATA CONNECT 64000 lt 040890880 gt Stollmann Entwicklungs und Vertriebs GmbH 37 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the T
104. sented with extended result codes 3 RING and CONNECT including ISDN address 4 RING and CONNECT including X 25 userdata available for X 25 protocol only prot 20 21 5 disconnect message include error causes ATW4 1 Result is presented with extended result codes 2 RING and CONNECT including ISDN address 3 disconnect message include error causes 4 and the current date and time in addition to the CONNECT message See also 3 2 3 AT result codes amp W Store active configuration The active configuration will be stored in non volatile memory AT amp W Xx Reduce result messages Reduces the number of result messages after trying to set up a connection ATXO CONNECT only without line speed ATX1 CONNECT with line speed BUSY NO DIALTONE not used ATX2 CONNECT with line speed BUSY not used ATX3 CONNECT with line speed NO DIALTONE not used ATX4 CONNECT with line speed all messages used default Stollmann Entwicklungs und Vertriebs GmbH 27 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 3 Using the TA POX Z Load stored settings The active configuration will be reset to the stored configuration Must be the last command in an AT command line ATZ amp Z lt x gt lt nnn gt storing phone numbers The TA POX can store up to three of the most frequently called numbers AT amp Z1 AT amp Z2 AT amp Z3 AT amp Zx nn _ set entry number x to SDNnumber nn max lengt
105. software updates to store the operational software This software can be updated from a local connected PC via the COM port Please fulfill the following steps to update the TA POX Start a terminal emulation on your PC with the capability to run an X MODEM file transfer i e HyperTerminal Enter the AT command AT FLASH to start the update procedure The TA POX will send the message Erasing flash EPROM now Please wait After erasing of the Flash EPROM the TA send out the request of the download procedure with the 1kX MODEM protocol Start your XMODEM transfer now Ctrl X aborts Start the 1kX MODEM file transfer send file or upload by selecting the Transfer Send File menu point in your terminal emulation and select the new software The internal timeout of each X Modem block is set to 10 seconds After completion you will get the information whether the software update ended successfully or erroneous Positive result Loading procedure ended successfully Negative reason Checksum error for example Negative result Flash EPROM software is probably not executable The loaded new firmware will automatically start after a software reset Give the TA about 15 seconds to activate the new software Due to new functionality the last stored configuration setting may be lost please check before using Note 88 Due to an error it may be that no firmware is active within the TA This will be indicated
106. st6 mann TA HIX TA HUX TA POX TA SOC User manual ISDN Terminal Adapter Version 01 Date 06 2009 Stollmann Entwicklungs und Vertriebs GmbH TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 Exclusion of Liability Exclusion of Liability The present manual by Stollmann Entwicklungs und Vertriebs GmbH hereinafter referred to as Stollmann reflects the present state of the art of the products described therein We have endeavored to give a description that is as complete and clear as possible in order to make work with our products as easy as possible for you All the same the manual may contain technical inaccuracies and typing errors As a result of the rapid advance in the art we must also reserve the right to incorporate technical alterations and developments without separate advance notice That is why Stollmann does not give any warranty for the contents of the manual and for its continuing applicability Nor is Stollmann liable for any loss of information or any incorrect use of information that might result from consultation of the manual Particularly Stollmann is not liable for damage nor indirect damage including damage caused by financial loss delays affecting business transactions or interruptions of business and similar consequences arising from the use or improper use of this manual not even in the case where it was pointed out to Stollmann or an agent of Stollmann that such damage might be sustaine
107. t will increase in terms of the configuration parameter txfwd The default value of txfwd is set to 0 O 4 character timeout If txfwd 100 equals 1 second the timeout of receiving the OK message will be around 2 seconds Supported commands A Repeat last command line This command repeats the commands of the last entered command line Note No prefix AT is required A A Accept incoming call Using this command you can accept an incoming call if automatic call acceptance is not set Register S0 0 An incoming call is displayed by the message RING or the code 2 The time interval to display the incoming call RING or 2 can be configured with the S register S80 The default value is set to S80 50 which is equivalent to 5 seconds The serial status line RI will toggle during the active RING state uniformly distributed according the half time of register S80 This command must be the last command in an AT command line ATA 18 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX B B channel protocol Transmission protocol for data communication in the B channel ATBO V 110 asynchronous ATB3 HDLC async to sync conversion PPP asynchronous ATB4 HDLC transparent octets are packed into HDLC frames ATB5 Byte transparent voice connection raw B channel data ATB6 Byte trans
108. t of serial output to the trace module bit 0 enable serial data to the trace log bit 1 enable serial status lines to the trace log available values 0 disable serial output to the trace log 1 enable serial data to the trace log 2 enable serial status lines to the trace log 3 enable serial data and status lines default shidle Short hold Idle data timeout option Short hold mode is activated if the parameter is set to a value unequal 0 Timer to disconnect the ISDN B channel connection after inactivity sec 0 inactive 1 n delay time to disconnect in seconds 1 255 default 60 seconds shto Short hold Call timeout to abort option Time to abort a call if not successful connected after n seconds n 3 255 default 15 seconds 82 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set shpa Short hold Call pause option Set a call pause for n seconds before next call attempt 0 immediate call retry 1 n call pause in seconds 1 255 default 3 seconds shtry Short hold Maximum number of connection attempts opt This parameter defines the maximum number of connection attempts until the connection to the application is disconnected If the number of not successful connection attempts is greater than the value of the parameter shtry the connection to the application will be disconnected The disconnect
109. ternal memory in 64 byte steps equals 8ms steps The minimum buffer size can be set to 256 byte The maximum value is 3968 byte The step size is 64 byte which equals 8ms Example t 200 ms delay time must be divisible by eight bch1delay delay time in ms 8ms x 64 Byte 1600 byte This table list a selection of typical parameter 64 bytes 8ms bchidelay byte 256 512 1024 1600 2048 2560 2880 3200 3968 B channel delay inms 32 64 128 200 256 320 360 400 496 bchloop ISDN B channel loop This parameter indicates the data loop in the ISDN B channel which can be set with S register ATS31 1 The ISDN B channel loop must be set with ATS31 register and will automatically saved to the configuration parameter bchloop bchloop ISDN B channel loop 0 B channel loop disabled ATS31 0 1 B channel loop enabled ATS31 1 bchloop return the configured ISDN B channel loop which is set with ATS31 0 1 Stollmann Entwicklungs und Vertriebs GmbH 67 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set br baudrate asynchronous Selection of the asynchronous baudrate for the DTE interface Autobauding automatic local bit rate adoption default 1200 bit s 2400 bit s 4800 bit s 9600 bit s 19200 bit s 38400 bit s 57600 bit s 115200 bit s 230400 bit s 20 300 bit s 21 600 bit s 26 10400
110. th usage of just B channel B2 14 leased line with usage of both B channels option option option option option option option option k windowsize Layer 2 protocol windowsize default 7 k 1 7 Value will be automatically changed with changing B channel protocol prot The default value for prot 21 X 31 D channel is set to k 3 load Load stored parameter setting All parameters stored in non volatile ram will be loaded 76 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set Itc lowest 2 way channel X 25 B channel Lowest switched virtual logical channel for incoming and outgoing X 25 connections Itc 1 4095 default 1 The value range for this LCN logical channel number can be set from 1 to 16 LCN bit 1 to bit 4 LCN values from 17 to 256 LCN bit 5 to 8 are currently not supported These LCN values will fail within the outgoing call with the result code NO DIALTONE Explanation of X 25 channel number structure Logical channel group number Logical channel number LCGN 4 bit length bit 9 to 12 LCN 8 bit length bit 1 to 8 XXXX 0000 XX XX Example LCGN 0 and LCN 1 Itc value 0x001 1 LCGN 0 and LCN 5 Itc value 0x005 5 LCGN 2 and LCN 10 Itc value Ox20A 522 LCGN 4 and LCN 1 Itc value 0x401 1025 LCGN 15 and LCN 1 Itc va
111. toggle during the active RING state uniformly distributed according the half time of register S80 Note The time interval to display the incoming call RING or 2 can be configured with the S register S80 S1 Ring Counter S1 is incremented each time the TA signals the RING message to the serial interface This parameter is read only Note If parameter SO is set to 0 the ring counter is disabled 32 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 3 Using the TA POX S2 Escape Character S2 holds the decimal value of the ASCII character used as the escape character The default value 43 corresponds to the ASCII s3 Carriage Return Character S3 set the decimal value of the ASCII character for the command line and result code terminator character The default value 13 corresponds to Carriage Return S4 Line Feed Character S4 set the decimal value of the ASCII character recognized as a line feed The Line Feed control character is output after the Carriage Return character if verbose result code is used The default value 10 corresponds to Line Feed S5 Backspace Character S5 set the decimal value of the ASCII character recognized as a backspace This character can be used to edit a command line The default value 08 corresponds to Backspace S7 Wait time for Carrier
112. vity sec 0 inactive default 1 n delay time to disconnect in seconds 1 255 Stollmann Entwicklungs und Vertriebs GmbH 75 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set iinit ISDN initialisation after power ON Defines the behavior of the TA after Reset If set to 1 the ISDN interface will automatically activated after Power ON As a result the LED1 will show the correct state regarding the ISDN line If set to 0 the TA stays passive to the ISDN line after power On the LED1 will stay blinking till the first successful communication through the ISDN line takes place iinitO iinit 1 iinit 2 iinit3 iinit 4 iinit5 iinit6 no activation after Power On Automatic activation after Power On Automatic activation every time the S Bus is deactivated Automatic Tei Request after Power On Automatic Tei Request and LAPD link setup after Power On Automatic Tei Request and LAPD link setup and RESTART after Power On ISDN point to point mode all connections will be cleared Automatic Tei Request and LAPD link setup permanently isdn ISDN D channel protocol note 1 Selects ISDN D channel protocol 0 DSS1 Euro ISDN 1 1TR6 Germany national 2 DSS1 NT mode Euro ISDN 5 National ISDN 1 2 USA 6 NTT INS NET Japan 7 AT amp T 5ESS USA option 8 VN4 France 12 leased line with usage of just B channel B1 13 leased line wi
113. which is automatically set in the additional e of the dial command from the connecting Stollmann ISDN TA rpwd password Password for remote configuration character input max length 32 character To disable password please enter rpwd default rpwd no remote password is set rpwd nn set rpwd to nn string of digits max length 32 rpwd show current setting of rowd rstmsg startup message Startup message Press lt CR gt lt CR gt lt ESC gt lt ESC gt to enter TA configurator after start up can be displayed with a fixed speed of 9600 bps 8 data bits no parity 1 stop bit 0 inactive no startup message will be send after power on default 1 active startup message will be send after power on rsttim startup timer Startup delay timer after reset Within this period the configuration can be entered after reset 1 255 reset phase in 100 milliseconds default 40 4 seconds Stollmann Entwicklungs und Vertriebs GmbH 81 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set save store parameter changes Stores the actual set of parameters in non volatile memory sbits number of stopbits Number of stopbits of asynchronous character 1 One stopbit default 2 two stopbit Note To use other data formats than 10 bit N1 7E1 701 you have to set br to fixed speed sertrce serial link trace Controls the par
114. xnr to nn string of digits max length 15 xnr erase the current value of xnr value xnr show current setting of xnr Only necessary if not supported from the network X 31 B channel only Stollmann Entwicklungs und Vertriebs GmbH 85 TA HIX TA HUX TA POX TA SOC User manual r01 06 2009 4 TA Configurator command set xtab lt n gt X 25 translation table xtabx lt xadr gt i lt nn gt set entry number x to SDNnumber nn and X 25 address xadr xadr To find an entry the x25addr is compared against all entries of xadr The xadr can contain wildcards ge represents one or more digits represents exactly one digit nn ISDN number The ISDNnumber nn can contain following wildcards xtabx clear entry number x xtabx show entry number x xtab Show all entries Maximum number of entries 5 x 1 5 Maximum length of ISDN number 20 digits Note The table is valid for X 25 in B channel and X 31D rerouting only Examples xtab1 45400029003i04089928392 lt cmd gt more information for one command Displays the allowed values for one selected command lt cmd gt 2 help Displays help texts for all commands 86 Stollmann Entwicklungs und Vertriebs GmbH r01 06 2009 TA HIX TA HUX TA POX TA SOC User manual 4 TA Configurator command set Notes Note1 After issuing one of these parameter you should execute the save command to store the configuration in non volatile memory
Download Pdf Manuals
Related Search
Related Contents
Normativa Medife AC Trane Gas Unit Heaters Installation and Maintenance Manual l`oreal paris 形E3JM/E3JK Untitled - Poolparadies Moxi Z User Manual OS4 25600 ISO HDR Philips 15W E14 Mode d`emploi Copyright © All rights reserved.
Failed to retrieve file