Home

Direct-Viewing Digital Crane Scale Model: DWP

image

Contents

1. Remarks 1 Preheat 8 10 minutes by turning the power on before operating and set up the data first according 00000 00000 03000 03000 03000 03000 03000 to Parameter setting 2 This operation must be within one minute after startup and data setup 3 1 Press H to quit at any time and return to weighing status the data could only be effective and input calibration weight value The highest digit flashes press A to choose figures Press A the flashing move to the next digit same way for other digits Press three time to input 3 flashing stops after selection of all the figures Then press A to make the highest digit flash re input the calibration weight value Otherwise press to calculate Zero Tracking parameter Calibration parameter and save the data automatically quit the calibration and return to weighing status During this process when the figures are flashing the flashing number will minus by 1 after each pressing on 0 on the remote saved after all procedures completed 4 Weight for weight calibration would be better as it be closer to the max weight If the loaded weight is lt 10 F S the calibration is invalid the original calibration parameter is still valid 5 If the five digits input by the user are all 9 it will restore the factory parameter 6 It can not enter into Calibration under the Tare status 7 It will automa
2. each press minus the parameter by 1 Press Quit the setting and back to weighing status Remarks 1 Can quit Setup at any time and return to weighing status the data becomes effective only after all processes completed 2 The bigger setup data the more stable weighing and with longer time for staying stable And vice versa 3 The original setup gravity is 9 7936 The user can adjust it into local one program will automatically correct the gravity If the user has calibrated at the local the gravity doesn t need to be adjusted Chapter8 Weighing Demarcation amp Compensation Demarcation 1 Calibration this operation must be after password setting The initial password is 33333 Press A for plus and 0 lt _ for minus for confirmation and enter into next step press H to quit setting mode Operation Display Remarks Option CAL 1 Parameter setting CAL 2 Calibration Press CAL 1 Switch to calibration operation Enter into calibration status Press A CAL 2 Press xx k x check scale ZERO Make sure the scale is empty and check if the display is zero If not press TARE ON OFF on the scale panel or gt 0 lt on the remote to make it zero If it is zero enter to next step 00000 Load weight load weight as close as to the max capacity t Load weight on the scale is the weight after loading Enter into input of calibrating weight status
3. 9 and release the button reduce value by 1 per second speed display If the weighing is not stable it will show for waiting When it becomes stable it will tare automatically and shows Zero with the Tare indicating light on if the weight lt 10 or 2 F S Zero it and it will show 0 with Tare indicating light off If the display value reduces by 1 per second showing tar x press Tare On off button it will start measuring the voltage and showing the value and shutdown automatically by releasing the button In the state of Tare with the tare light on press the button Tare On Off or the button on the remote tare clearance and it will show the gross weight and quit tare Tare indication light off 5 4 Check Look back the past 5 weighing records The green button at the front panel of the scale is for checking Press once for the latest display Showing LSt 1 for one second and the value for 4 seconds twice for second latest display and so on It will show max 5 records at one time by pressing the button It returns to weighing status 5 seconds after checking the record In the state of checking press Tare On off to quit checking weight value immediately and return to the weighing status 5 5 Net weight accumulation When the auto accumulation function is off and the net weight gt 20d display becomes stable press to manual accumulate the net weight and it will show n xy and return to weight
4. Od Zero tracking range Press A to choose the required zero tracking range Option 0 9 each accordingly as below 0 0 45d 1 0 6d 4 0 9d 2 1 0d 8 2 5d 9 3 0d Enter into next setting filter wave figure match 2 0 7d 3 0 8d 6 1 5d 7 2 0d Set filter coeffition L stand for times of smooth views L 8 20 Press A to set the parameter of wave each press the parameter adds by 1 Enter into next setting Power saving Jd Option 0 off 1 on Press A Press 4 for options K Jd 1 Enter __into next ___setting Auto Press accumulation LJ x Option for auto accumulation 0 Off Press A 1 On 8 Press f LJ 1 Press A for option Enter into next setting Weight unit Lg x Press A for weigh units option Press 0 kg 1 Lb 9 Lg 1 Only the LED display has this function Enter into _next setting Gravit Press Speed Set gravity parameters Remark 3 9 x x The highest digit is 9 and the one next to it flashes press A for option Press Move to the next digit for selection 10 Press 93000 After all digits set it stops Press 93000 flashing Press 93000 When press A the next high digit 93000 flashes restart setting 93000 Enter _into _next__ setting Back lightness of LCD brt Set backlight brightness for LCD Press A to select the brightness Press A brt 6 Brt 1 64 Press gt 0 lt on remote
5. every two months and 12 hours for one time 1 3 If you have to replace the battery by yourself don t forget applying water proof glue to the welding exposed area 1 4 This product is a sophisticated electronic equipment Keep away from violent collision and moisture 1 5 Over lifting may cause permanent damage or incident 1 6 To ensure the safe use please check all screws amp pins for loose or falling before use Chapter 2 General Introduction This direct viewing digital crane scale is combined by hanging part high precision transfer A D converter and display The layout is as below This display with 1 2 super bright digital screen or LCD with 5 digits allows clear reading from far away Advanced compassed circuit and unique data processor make this crane scale a real accurate convenient and reliable weighing equipment used in the warehouse dock plant and lifting occasions etc Chapter3 Scale characters Accuracy Class National Scale Standard Grade 3 Low power design with auto power saving 100 hours continuous use after charging Over discharging protection circuit protects the battery from life shortening or damage caused by over discharging Percentage of battery capacity display at startup and shutdown helps good knowledge of the battery and in time charge High compassed high reliability Power saving mode and auto turn off function Optional Tare hold and accumulation functions Stable weig
6. front panel or gt 0 lt on the remote for one second showing tAr 9 release the button and press again to display the battery capacity like pbt85 then release the button to automatically cut off power supply 5 1 3 Energy saving mode and auto shutdown This function is optional check details in 7 section parameter setting When the weighing is continually stable or at Zero status for 15 minutes it enters into power saving mode each digit on display shows _ one by one When button or weighing changes it automatically returns to normal weighing display After 60 minutes continual steady weight it will automatically cut off the power and shutdown 5 2 Maintaining and lifting the weight display Press button H to hold the display which won t change when real weight changes Press H again to life the display enters into normal weighing process 5 3 Tare Zero 5 3 1 Tare Zero In the Tare off state life the goods and press the Tare On off button or the gt 0 lt on the remote the scale will remove the weight and display will only show 0 or 0 0 f the weight is lt 10 F S Zero it whatever the weighing is stable or not it shows 0 and the Tare light off if the weight is gt 10 F S and the weighing is stable then tare it shows Zero and press Tare If the weighing is not stable then nothing needs to be done 5 3 2 9 seconds to automatically tare delay Press Tare On Off button for one second showing tAr
7. status in 2 seconds N stands for net weight accumulation xy stands for times of accumulation Next net weight accumulation will only be after the net weight showing value 20d empty Max 99 times When the auto accumulation function is on it will automatically accumulate when the display value becomes stable Next net weight accumulation will only be after the net weight showing value lt 20d 3 empty Max 99 times 5 6 Display and clearance of net weight accumulation value Press A button in the state of weighing it will show accumulated times of the net weight n 20 press again it will show the highest 4 numbers H _ 10 press once more it will show the lowest 4 numbers L5000 press again to return back to weighting then the net weight accumulation value is 105000kg When there are the above three figures press gt 0 lt to clear the times and the value Press Tare On Off to quit net weight accumulation and return to weight status 5 7 Charging Instruction When the battery is less than 15 the light will flash and remind user to charge in time When the battery is less than 10 it will automatically cut off the power will not cut off during self inspection when scale starts to prevent from over discharging of the battery The plug hole is at the back of Crane scale It takes about 12 hours to charge up every time 5 8 Error Indication 1 Over loading indication when the weight of weighing is more than the full weigh
8. the Replace to socket with electricity or press down the Battery can not be charged up down the socket socket light is on button button Battery damaged eye OPUF Cline CNarger BUL no Replace the battery voltage going up after connected Plug damaged Sometimes it works when shake the charger connector Replace the charger Short battery life Not our charger Long term damage to the battery over voltage charge Check if the output power is more than 8V Replace the charger our company s charger output is 7 4 7 8 Battery Lifetime expired The voltage drops down fast after charging up Replace the battery Self discharge caused by bad seal Battery polarity welding is not sealed or water in battery pack by poor sealed Seal the battery welding area and the battery case by glue Unstable display Items shake seriously while Intensely shaking or over shaking Wait till it is stable weighing The Manse ds The output and input of the damaged by over j transfer change too much or the Replace the transfer with the loaded or the j value is 1 when use Voltage meter manufacturer insulation is damaged at 20MQ The wire of transfer is broken or damaged Press at different area of the transfer wire the data changes obviously Reconnect the wires protect from short circuit Serious scale body moisture See vapor inside after op
9. DIGITAL SCALES TM DiciUWs ics Direct Viewing Digital Crane Scale Model DWP C2X User Manual January 2012 Preface Thanks for choosing our products In order to properly utilize the product and fully realize its superior performance please read the manual carefully before use Copyright no 2012 1 Content Chapter 1 Proper use and maintenance ccciciccicicciciccicicciciciicecsicecsccececcececseceas Chapter 2 General Introduction estier iki airain ei iie aiae adidas Chapt r 3 7 Scale CcharaCtetfsSc 2 24422592254250609 a e Rt Chapter 4 Main Technical functiONS cccccciciciiciciiccciccecsccicsccicecsscecsccecsccececcececsenens Chapt r 5 Operation meseros ere derer Receto e R estes navies ir ii Chapter 6 Password Put mansion A S Chapter 7 Parameter setting Setup sssssssssssssssessessestssssrsssstsesesestssesesstsessesessesesesesese Chapter 8 Weighing Demarcation amp Compensation Demarcation scciciaiaae Appendix 1 Glitch and self maintenance ccicicciciciicicciciciiciciiciciicecscciceccececsacens Chapter1 Proper use and maintenance 1 1 This charging circuit is uniquely designed requiring lower voltage than regular ones make sure do NOT use other chargers or it could be burned or become non chargeable 1 2 The Crain Scale should be charged regularly in case the damage of the battery as it is with self discharge usually once for
10. en the front cover Dry wet parts Insufficient welding during maintenance Welding points not smooth or with small gaps Redo the welding Insert loose check the loose by eyes or shake the insert the value changes Re plug or replace insert Not show 0 when the scale empty The preheat time is not enough when startup Preheat time 3 5 minutes Shows 0 after 3 5 minutes Startup when the scale is not hung up Should startup with hung up empty scale Zero Huge tolerance of weighing value Inaccurate reference standard Reference to standard is not a standard weight not test or test for a long time Calibrate with standard weights or weight together with a new scale from the distributor Inaccurate placement hanger of the Check if any rope messed up over side load protruding after knotted during weighing No no Avoid any slapping centered make sure stuck of the hanger Remote not working Low battery Check the battery capacity Replace battery Long distance Move closer to the scale Button failure Other buttons work normally Replace the remote 10
11. er input the password correctly 3 After complete the password input it will automatically quit accumulation status 4 Can not enter into password input under Tare status Chapter7 Parameter setting Setup 1 Can not have parameter set under the Tare situation should quit first 2 In the state of Parameter Setting press A will plus every press on 0 lt will minus press as confirmation and enter into next operation press H to quit setup status Operation Display Remarks Press after password confirmed CAL 1 Option CAL 1 to setup the parameter CAL 2 to enter into calibration Set decimal digits Press A to choose the decimal digits option 0 1 2 3 Enter __into __next _ _ parameter setting Division Value Set Division Value Press A to select the required Division value Enter into next setting Ek 00000 03000 03000 03000 Set the max Weighing range With the highest digit flashing press to choose the figures The fourth digit flashes press to choose the figures for example press 3 times of A it will show 3 Press the figures stop flashing Press A when the highest digit flashes enter into resetting the max Weighing range Otherwise if press it will automatically show the overload warning value of FS 9d Enter _into next settin Zero tracking range Set Zero trace range
12. hing which will not be effected by shaking Convenient wireless remote can be operated within 20 meters for zeroing record checking and shutdown High heat insulation and anti erosion versions are available Chapter 4 Main Technical functions Applicable temperature range 10 C 40 C Relative Humidity lt 90 RH Display 5 digits super bright 1 2 LED digital tube or LCD letter highness 40mm New advanced high precision SCM with extremely strong magnetic resistant function and reliable steady weighing Gravity correction function makes it suitable for all over the world Safe over lifting 150 F S Damaging over lifting 200 F S Steady reading lt 5 seconds Precision Grade Ill 10 Zeroing range lt 10 F S 11 Tare range 10 100 W N d jp dt Yv ON O UI Chapter 5 Operation 5 1 Switch On Off 5 1 1 Startup Under OFF situation press Tare On Off on the front panel switch on and release the button when the display shows on It first shows UEr6 0 of the copyright and self check showing figures 9 0 in one second With decimal point tare stability lights flashing on then it shows the battery capacity percentage as pbt85 then it enters into zero reformat showing it will not show if the reformatting has been completed after self check By the end of Zeroing it shows 0 or 0 0 entering into weighing status 5 1 2 Shutdown On switch on regime press button Tare on off in the
13. ing range plus 9d it is over loaded and shows OF 2 Error Notice The weighed value is negative and the highest no is not 0 or 1 it will show E rr Chapter6 Password Input 6 1 This operation should only be taken within one minuet after startup and can only enter into parameter set up and calibration after inputting the password correctly 6 2 Under this function press A button the number move up 1 by each pressing every press on button 0 lt the flashing no will reduce by 1 press button to confirm and the flashing position will move rightward by one bit For example Operation Display Remark Press H till 2k 2k 2k k It shows the value under weighing display status 4 shows 00000 00000 Enter into password inputting the highest digit will flash The password is 33333 PRESS A Press 3 times of A it will show 3 Press 30000 Press one time of the flashing Press A no will move rightward one bit 30000 Press 3 times of A the number will 2 show 3 33000 After all done Press once it will stop flashing press If press A Highest digit flash to start resetting the password If input incorrect password it will return back to weighing state If input correct password it will enter into Calibration Remarks 1 Press H button to quit the password inputting at any time and return to weighing status 2 Can enter into parameter setting and calibration only aft
14. tically quit Accumulation status after this process 2 Compensation calibration must be after password setting E g When the actual weight on the scale is 1 000kgs but it shows 1020kgs it can be corrected by compensation without taking off the weight from the scale Details show below Operation Display Remarks After inputting password Press A Press Option CAL 1 Parameter setting CAL 2 Calibration Press A and enter into calibration Enter into Compensation status shows current weight value Press into next operation 1020 Press repeat step 4 of calibration Appendix 1 Glitch and self maintenance Error Reason Check method Solution Use power meter to measure the Battery pack voltage of the two ends of battery Replace battery lower than 5 0V means damaged breakdown Unable to startup Bad connecting of battery wire Shake gently the connecting wire Reconnect or weld the battery wire Open the front panel and the two Charger indicator does not light eel bution ends behind the short circuit Replace the On Off button damaged on off button can be startup Charger damaged onnee rough Me Powel me Replace charger charger light not on voltage meter shows less than 8V output Charger not plug on Less than 8V output check the plug connecting Re plug on the charger No electricity on the socket or not press Use Volt meter to check if

Download Pdf Manuals

image

Related Search

Related Contents

Samsung PS-42P3SR Инструкция по использованию  Modèle KX    Hama 00106960 weather station  VPCY21 Series  DO9200IB - Vandenborre  PC de Secretária ASUS  2 - yodobashi.com    水晶発振式成膜コントローラ CRTM-9100G  

Copyright © All rights reserved.
Failed to retrieve file