1. 15700 Intruder Alarm Control Panel EAB i oO om ee eel 2 6 aa ca ca Sta rb urst User Operating Instructions Bell Test Chime Digicom Duress Exit Entry Route Entry Time Exit Time Exit Terminator Full set Final Exit Log Master User Night Circuit Omit Part Set Passcode P A Panic Alarm Remote Keypad Reset Tamper Alam unset Users Walk Test 24hr Circuit Glossary Of Terms A facility to testthe operation of the extemal bells stobesand the intemal sounder An optional facility which allows detectors or door contact devices to generate a two tone chime if activated whilst the system is unset Digital Communicator A remote signalling device fitted to the system which will tansmit alarm information via the telephone line to the alam receiving cente Ameansof entering a passcode firsttwo digits ofa passcode reversed which will generate a silent alarm via the remote signalling device if fitted to the alarm receiving cente The route which must be used for entering or leaving the protected premises when the system is being set or unset Apresettime delay to allow the userto enterthe protected premisesand access the remote keypad without causing an alarm A presettime delay to allow the userto leave the protected premises or area when the system is being set by the timed exit method An extemal push button switch used
2. 2 Press sc within 5 seconds 3 The display will show OPEN and then revert to the current time Engineer Reset 1 Enter your passcode 2 Press sc within 5 seconds 3 The CALL ENGINEER message is displayed and the engineer must now be called to reset the system Remote Reset 1 Enter your passcode followed by EN within 5 seconds 2 e display will show USER 1 3 Press 3 the display will show a four digit seed code 4 Telephone yourcental station orinstallation company and quote the seed code They will quote you a four digit Reset code in retum 5 Enterthe Reset code and press EN A low tone indicates the Reset code waseitherinc orectorinconectly entered A high tone indicates the code was accepted 6 Press to retum to the OPEN condition Enter passcode before entry timer expires MCh Lot System is now unset OPEN TATI CIIN System requires an engineerto reset or Remote Reset The four digit seed code Note This code is only an example The four digit Reset code entered TS700 Sta rburst User Operating Instructions User Menus Quick Reference Esc Retum To Open LL Bell Test 2 Walk Test 3 Remote Reset 4 Change Passcode 5 Enable Chime E Omit 24 Hour Group 7 Omit Circ uits 8 Silent set LO Full Set A Part Set Group A B Part Set Group B C Part Set Group C ent User Menu 2 LL View Circui
3. present at the end of the exit time an intemal alarm will be generated If fitted the extemal strobe light will flash indic ating the system has failed to set To prevent thisalarm simply re enteryourpassc ode before the time expires 3 Part Setting the System users 1 To 9 Ensure that all monitored areas are secured Enter your passcode users 1 to 9 only and within 5 seconds press A or B or C depending upon the part set area required If the five seconds is exceeded the system will full set The display shows the selected group area that will be omitted and the sounder makes a continuous tone If required leave via the normal ext route and close the final exit door pressing the Ext Terminator button if fitted The system is partset when the exit sounderstops the display will altemate between the group area thatis omitted and the current time This is the normal display when the system is set or unset The time is displayed and the dot segment flashes Enter user passcode to clear This figure indicates the time to set in secs 9999 indicates the system is being set by Last Ext or Exit Terminator Any other figure is timed ext The display shows the group that has been omitted A 2 TS700 Sta rburst User Operating Instructions 4 Part Setting using Part Set Codes Ensure that all monitored areas are secured Enter your passcode the ext sounder will make a continuous tone If required leave via the normal
4. to complete the setting of the alarm system State of the system when it is protecting all of the premises The doorordetectorthatis used forleaving and entering the premises A recor of system activity 200 events which is stored in memory The person in overall charge of the system i e the person who allocates the passcodes to all other users Acircuitthatarmed when the system is full setorpartset if programmed To intentionally exclude the monitoring of one ormore detection circuits when setting the alarm system The state of the system when it is protecting part of the premises A unique four digit code numberallocated to each userby the master user which must be entered before the system can be operated An emergency push button switch used to triggeran alarm The alarm signal will also be transmitted to the alarm receiving centre if a remote signalling device is fitted A device located away from the main contol panel that is used to operate the alarm system Action required to retum the system to its normal state afteran alam An alarm caused by the system being physically interfered with State of the system when itis notmonitoring the activity of Night circ uits Those people allocated a passcode which allows them to operate the alarm system A facility for testing circuits without sounding the extemal sounder A circuit that is continuously monitored TS700 Sta rburst User Operating Instructions Contents Sy
5. 8 amp 9 in User Menu 2 are only available if programmed by the installation company TS700 Sta rburst User Operating Instructions User Menus 11 Introduction In addition to setting and unsetting the system users 1 9 may cany out other operations These are selected via two user menus UserMenu 1 isavailable to users1 9 and UserMenu 2 which is only available to the masteruser To access User Menu 1 enter your passcode and then press Ex within 5 seconds Pressing Esc retums the userto the previous position in the menu 12 Bell test This test allows the user to test the bells sounders and strobes 1 Ensure that User Menu 1 is selected 2 Press I to select the Bell Test option 3 The sounders bells and stobes will operate sequentially for 9 seconds each 4 Testing maybe stopped by pressing Esc oradvanced to next test by pressing Ent 5 Press sc to retum to the OPEN condition 13 Walk Test This test allows the user to test the function of individual circ uits without creating analam Aseach circ uitis activated itsnumber and status are displayed and the intemal sounder generates a two tone sound As more circuits are tested they are added in tum to a scrolling display showing the status of each tested circuit 1 Ensure that User Menu 1 is selected 2 Press 2 to select the Walk Test option 3 Activate circuits in tum by opening doors with contacts and walking in front of detector
6. Chime Circuits option 3 Circuits will be displayed as Y to chime or N not to chime Change status by pressing 0 toggle action 4 Press to accept high tone and go to next circuit Circuits may be selected by number Press fsc to quit 5 Press twice to retum to the OPEN condition 23 Configure 24hr Omit Group This option allows the master user to select the 24 hour circuits that will be omitted when the 24 hour omit option is selected in User Menu 1 option 6 1 Ensure that User Menu 2 is selected 2 Press 6 to select the 24Hour Omit Group option rer IUN mins di Circuit 01 will not chime Press 0 to change rrr ru Lhe ot Circuit 01 will chime Press ENT to accept LI TS700 Sta rburst User Operating Instructions 3 Circuits will be displayed asO Omitted orA Amed Press 0 to change toggle action 4 Pressi to accept high note and go to next circuit A low tone indicates that the circuit cannot be omitted 5 Circuits may be selected by number Press Esc to quit Press Es twice to retum to the OPEN condition 24 Print System Log Circuit 02 will remain Amed Press 0 to change rer awa Lhe Lei 4 Circuit 02 will be omitted Press ENT to accept A printer may be connected to produce a printout of the last 200 system events 1 Ensure that User Menu 2 is selected 2 Press 7 to select the Print Log option 3 Enterthe number of events
7. EN to accept 5 A high tone will indicate acceptance A low tone sound will indicate thatthe passcode is already in use 6 Press sc twice to retum to the OPEN condition To delete a user passcode from the system select the user number you wish to delete at step 3 then enter your own passcode master user at step 4 Passcode Types Waiting for passcode type 1 9 or A or B or C L Waiting for new passcode to be entered New passcode 5750 entered Press ENT to accept Master User Code 1 This passcode allows setting and unsetting of the system and allows entry to both user menus Standard User Codes 2 7 These passcodes allow setting and unsetting of the system and entry to User Menu 1 Cleaner Code 8 This passcode allows only setting of the system and entry to User Menu 1 Holiday Code 9 This passcode allows setting and unsetting of the system and allows entry to UserMenu 1 The code is erased from the system when the master user code is next used to unset the system Part Set Code A A This passcode allows the setting and unsetting of group A Part Set Code B B This passcode allows the setting and unsetting of group B Part Set Code C C This passcode allows the setting and unsetting of group C 22 Configure Chime Circuits This option is used to select the circuits that will chime 1 Ensure that User Menu 2 is selected 2 Press 5 to select the
8. ext route and close the final ext door pressing the Ext Terminator button if fitted The system is part set when the ext sounder stops the display will altemate between the group area which hasbeen amed and the curent time 5 Setting with Circuits Omitted It may sometimes be desirable to omita circuit when full or part setting the system 1 Enter your passcode users 1 9 and press within 5 seconds 2 Press and the display will show the circuit number followed byits omitstatus N notomitted and Y omitted 3 Press 0 to change the status of the circuitand En to confirm the change A low tone will indicate that the circ uit cannot be omitted ora high pitch multi tone indicates that the change hasbeen accepted Continue with the next circ uit if required 4 Pressf sc to quitto usermenu 1 and continue with setting by pressing 0 forfull set or A or B or C forpart set see 2 and 3 6 Silent Setting The system can be full set or part set silently except for the final system set sound Enteryourpassc ode users 1 9 and forfull set press 8 within 5 seconds For part set press A or B or C then press 8 Altematively Enter your passcode users 1 9 and press EN within 5 seconds Press 8 and the display will show SLENT Enter 0 for silent full set or A or B or C for silent part set 7 Setting and Unsetting With a Keyswitch Operate the keyswitch ordoorlock and leave via the extroute The sy
9. gnation Record Location Omit Chime 18833 Drg No 33 2159 00 Issue 01 Doc 04 August 98
10. ja na retete 10 25 Configure Pat Set GroupS 1 eee nee 10 26 ViEWSYSIEMILOG i ois e acta ole Kan Ra a Ral a ale ce 10 Table 1 Log and Display Codes 0 cece cece 11 Serice RECO n ri cea e ic tenia Poa ahaa ae E DU weds 12 USE RECON caen tana ci ue a acts aie E aed Wein we ua a aco au a Ae 13 System Configuration Record ce 13 Circuit Designation Record ce Back Cover System Overview The 15700 intruder alarm control system uses state of the art electronics to provide a comprehensive but flexible protection for both domestic and commercial premises The system comprises a numberof components linked to a central contol unit which is concealed from view butaccessible formaintenance All system operationsare camed outfrom one of the remote keypads up to four may be connected Detection devices such as doorcontacts or movement sensors are allocated to detection circuits which are identified on the remote keypad displays Each alam installation is specific to the site and its occupier and may differ from other TS700 installations This manual describes in detail all the functions and procedures available to the user To avoid unnecessary operating enors please discuss the details of the system with your installation company before attempting to use it TS700 Sta rburst User Operating Instructions Operating the System 1 Introduction System operation can only be canied out after entering your passcode Up
11. lect the Change Time option 3 Enterthe time in 24 hour notation e g 1805 4 Press i to accept 5 Press sc twice to retum to the OPEN condition 20 Change Date The system calendarmay be changed by entering the date as fourdigits representing the day and month e g 0207 is the 2nd July 1 Ensure that User Menu 2 is selected 2 Press 3 to select the Change Date option 3 Enterthe date as four digits 4 Pressi to accept 5 Press sc twice to retum to the OPEN condition 21 Setup New Users Up to 12 users can be allocated to operate the alarm system The master user user 1 can change all user passcodes If a passcode is entered with the first two digits reversed a Duress Alarm is generated If this facility is not required ensure that the 1st and 2nd digits are the same e g 1123 If a passcode is entered with the last two digits reversed the Access Control outputis operated Ifthisfacilityisnotrequired ensure thatthe 3rd and 4th digits are the same e g 1233 1 Ensure that User Menu 2 is selected Circuit 03 is Healthy Circuit 03 is Active Waiting fortime entry BL 15 Time entered 1805 6 05 pm 1 Waiting for date entry Po m ued i Date entered 02 J uly 8 TS700 Sta rburst User Operating Instructions 2 Press 4 to select the Setup New Users option 3 Enterthe usernumber 1 to 90rA B C 4 Enterthe new passcode then press
12. mmed bythe engineeror master user User Menu 2 option 6 will be omitted 1 Ensure that User Menu 1 is selected 2 Press 6 to select the 24hr Omit option 3 The display will show CIRCUITS OMITIED 4 Enteryour passcode to reinstate the omitted circuits 17 User Menu 2 master user only The masterusermay accessthis menu by pressing E when User Menu 1 is selected Options 4 to 9 are only available to the master user if programmed by the installation company Waiting for new passcode New passcode 2305 entered Press ENT to accept The Chime option is off Press 0 to change The Chime option ison 24hr circuit isolated Enter passcode to cancel Din sy MN a User Menu 2 selected TS700 Sta rburst User Operating Instructions 18 View Circuits This option allows the userto view the status of each detection circuit The circuit status conditions are H Healthy A Active S Shorted or T Tamper Ensure that User Menu 2 is selected Press 1 to select the View Circuits option Circuit status will be displayed Select circuits either by entering the number or by pressing to scroll through the circ uits Press fsc to leave this option and retum to User Menu 2 6 Press sc twice to retum to the OPEN condition a eee SIA 19 Change Time The system clockmaybe changed using 24 hourclockformat 1 Ensure that User Menu 2 is selected 2 Press 2 to se
13. s Checkthe displayto verify which cir uits have been tested 5 On completion press E to quit the Walk Test option Press fsc to retum to the OPEN condition Count down display for Bell Test VIE CE to bah mN A Tes completed User Menu 1 selected ae ANIN IZ ae X Nove X d butno Walk Test selected but ni circuits have been tested Circuit 05 is now active Circuit 05 is now healthy TS700 Sta rburst User Operating Instructions 14 Change Passcode All users can change their own passcode 1 Ensure that User Menu 1 is selected 2 Press 4 to select the Change Passcode option 3 Enteryournew passcode and press kr 4 A high pitched multi tone indicates that the new passcode has been accepted A low tone indicates that the passcode isalready in use and hasnot been accepted Try again with a different number 5 Press sc to retum to the OPEN condition 15 Enable Chime The enable chime option allows a user to switch the chime facility on or off This will only affect circuits that have been programmed as chime in User Menu 2 option 5 1 Ensure that User Menu 1 is selected 2 Press 5 to select the Chime option 3 Press 0 to toggle the Chime ON or OFF 4 Press 7 to accept 16 Omit 24hr Group This option allows 24 Hour circuits to be omitted when the system iS unset so that they will not alam if activated but will alarm if tampered with Onlythe circuits progra
14. s alarm from usercode System on site reset LKI open on powerup ENALM xx Entry ala m from circuit Area set using part set codes ENTRE xx Entry from circuit Part set keyswitch operated IRE xx Fire alarm from circuit Tamperalam from circ uit FUSE ot Auxiliary fuse blown Time changed First knock from circuit Circ uit failed test Factory reset LK1 closed on powerup TEST GFF All circuits on test removed from test Full set UNSET x Area unset using part set codes Telephone line fault USER xx Usercode entered Telephone line restored NG EVENT No event Table 1 Event Log Codes 11 TS700 Sta rburst User Operating Instructions Service Record Engineer Installation Company Address ForService Telephone For Remote Reset Telephone 12 TS700 Sta rburst User Operating Instructions User Record User Type User Name Master Standard Standard Standard Standard Standard Standard CleanerCode Holiday Part set A Part set B Part set C System Configuration Record Entry Time Exit Time Bell Delay Bell Duration System Reset By Engineer Remote Reset 13 Circuit Desi
15. stem OVENVIE WI aa ig bat alan tan A v 1 Operating the System L INUOOUCUO N i a ie it a ea co cd a E ec a at AE a E aia 2 2 FullSettingthe System cena 2 3 Part Setting the System Users 1 9 2 nene 2 4 Part Setting the System using Part Set codes 0 cc cece ee eee 3 5 setting with Circuits Omitted 0 cece ee 3 6 Silentsetiing i ii teen agi canta nnd aia ea balet dee oat wale deg a 3 7 Setting and unsetting with a Keyswitch 0 0 cece eee eee 3 83 MSCUING caiete etic uniti tar teal ack BADE ati SN OS 4 9 Unsettingafteran Alam 0 ccc cee ete eens 4 10 Resetting afteranAlam 1 0 0 ccc cece eens 4 User Menus Quick reference 2 0 ects 5 User menus IL INTOQUETON ascii e ass ati a la avant du A each SB E 6 12 Bel IESE tat ie dine datare tatea dele ted teu ad a batea tolled ital e dota fate 6 13 OWAIK TSE ca arde A a a 6 14 Change Passcode ceea eee 7 15 Enable Chimps tri dotes eee ora tote deh ead ae aerial tei ode bes 7 T6 OMmt24 GUD saga dei aaa dp A A A A 7 17 User MENU Zaa aa alas bd eBay ein qd NT ad da lt a a 7 18 View CIRCUS es esoteric d dad eder 8 19 Change TIMES asi ahs oe ani a aer a Pa ta 8 20 Change DA upa a 70 ti E A EA DG a a cu a 8 21 Setup New Ubel puras fester de ea ded Goad Go ap a er be da 8 22 Configure Chime CircuitS seua tuna ma pa ae E dra e e A a 9 23 Configure 24hrOmit Group 0 e 9 24 Pint VSEM LOG cs dis descenso de jair sido dale de
16. stem will be full setor part set when the ext sounder stops To unset the system operate the keyswitch orlock again User passcode B entered Group area Bwill set in 15 seconds Group area Bis now amed rrr MI N hee oe 7 A Circuit 01 will not be omitted OOT fall hl mae Loe y Press 0 to change the status Circuit 01 will now be omitted User menu 1 selected ZNT SI LENT Press 0 for silent full set or A or B or C for silent part set W TS700 Sta rburst User Operating Instructions 8 Unsetting Enter the premises via the normal entry route and go directly to the keypad Enter your passcode The display will show OPEN and then revertto displaying the current time The sounder will sound at entry and will stop when the system is unset If the entry time is exceeded an intemal alam is generated and the entry timer is restarted If at the end of the second entry timer the system has not been unset a full alarm will occur 9 Unsetting afteran Alarm Enter the premises via the normal entry route and go directly to the keypad Enteryourpasscode The sounderwill sound at entry and will stop when the passcode is entered The display will show the circuitthatcaused the alam and the system mustbe reset 10 Resetting afteran Alam Your system is programmed as EITHER User Reset or Engineer reset consult your installation company if you are not sure User Reset 1 Enter your passcode
17. ted forthe selected part set group Press ENT to accept al ENA ST PONI Lt Log event showing Circuit Alarm OT Press A to scroll backor C to scroll forward Press B to view time and date 10 TS700 Sta rburst User Operating Instructions 5 Press B to show the time of the event first press the date second press the time in minutesand seconds third press the event again fourth press Press sc to quit Press sc twice to retum to the OPEN condition LM SENT Action alam Ala m outputactivated Lid tamper AuxtamperorSABtamper LESS xx Access passcode user code entered with the last two digits reversed System open unset DELAY xx Alam delayed the system is part set and circuit was activated Omitted circuits reinstated AUX xx Auxiliary alam from circuit PA alam from circ uit Battery Fault Power failure remote power LED flashes Bell test operated Power restored Circuit alam from circuit Part set area Comms successful Code tamper from remote keypad Comms failed RE ARM n uw System re armed Circ uits isolated 24 hour circ uits REM RST System reset by REMOTE CODE RESET Circuit omitted R REM xx Remote Keypad removed orlost Date changed RTMP xx Remote Keypad case tamper Default usercode 1 to 5678 SET FAIL System failed to set Dures
18. to be printed 4 Press E to start printing To stop printing select the menu againand enter000 asthe numberof eventsto be printed 5 Press sc twice to retum to the OPEN condition 25 Configure Part Set Groups When the system is part set certain circuits are omitted This option allows the master user to select those circuits to be omitted when part set A orBorC is selected 1 Ensure that User Menu 2 is selected 2 Press 8 to select the Part Set Groups option 3 Select the part set group A or B oric 4 Circuits will be displayed asO Omitted orA Amed Press 0 to change toggle action 5 Press P to accept displayed status high tone and go to next circuit Circ uits may be selected by number 6 Press fc to go to step 2 and Ed again to go backto User Menu 2 7 Press twice to retum to the OPEN condition 26 View System Log The time date and nature ofthe last 200 events on the system may be viewed starting with the most recent event 1 Ensure that User Menu 2 is selected 2 Press 9 to select the View Log option 3 Te mostrecent event will be displayed see Table 1 4 Press A to scroll backwards and C to scroll forward Enter the number of events to be printed Press ENT to start Enter part set group A BorC NOT TU Lee d Circuit 01 will remain Amed for the selected part set group Press 0 to change TT MLM Lee oe 4 Circuit 01 will be omit
19. to twelve passcodes can be allocated and they can only be defined by the masteruser user 1 Users A Band C can only set and unset their respective areas Entering a passcode with the first two digits reversed will cause a Duress Alarm Each key pressisacknowledged by the keypad sounder Pressing the ESC key takes the userbackto the previous step in the menu When the system isnotbeing used the keypad display shows the current time The ENGINEER ON SITE message is displayed afteran engineerhas left his menu and iscleared the next time a user passcode is entered 2 Full Setting the System Ensure that all monitored areas are secured Enter your passcode users 1 to 9 only and the display will show FUNCTION After five seconds the display will show how much time is left before the system is set and the sounder makes a continuous tone Leave via the normal ext route and close the final exit door pressing the Exit Terminator button if fitted The system is full set when the exit sounderstops the display will show T for five seconds then reverts to showing the current time WARNING If an attempt is made to set the system whilst any Circuits are active such asa doorbeing open the display will indicate the circuits that are in fault and the intemal sounder generates an interupted tone The fault must be cleared before the setting procedure can be completed If the system is set by Timed Exit and the faultis still
20. ts 2 Change Time 3 Change Date 4 Setup New Users E Change 24hr Group Z Print System Log 3 View System Log Esc User Menu 1 5 Change Chime Circuits 8 Configure Part Set Groups The system is unset the display shows the Curent time Enter user passcode The display shows Function Press fm within 5 seconds to select User Menu 1 Abandons UserMenu 1 and retumsthe system to the unset OPEN condition Allows the intemal sounders extemal sounderand strobe to be tested Allows all detection circuits to be tested without generating analam Reset the system by exchange of 4 digit codes Change your passcode Enable ordisable the chime option Omita pre defined group of 24 Hour circuits Select circuits to be omitted before setting the system Select silent full set or part set Full set the system Part set the system with group A omitted Part set the system with group Bomitted Part set the system with group C omitted Select User Menu 2 master user only User Menu 2 selected View the status of all detection circuits Set the system clock Set the system date Setup and delete user passcodes Select circuits that will chime Setup a group of 24hr circuits so that can be omitted Print the contents of the system log 200 events Configure part set groupsA B amp C View the contents of the system log Retum to User Menu 1 Options4 5 6 7
Download Pdf Manuals
Related Search
TS700 Starburst user operating instructions
Related Contents
Markt ¨ubersicht von Tagging-Werkzeugen und Vergleich mit tagstore Gigaset C530 apc documentazione tecnica consorzio cometa - Documents SERIAL BUS DEVICENET™ ADAPTERS 平成26年度 チャイルドシートアセスメント 試験結果 EFP-LC TypeE 取扱説明書 DataScout™ 10G Users Manual 540 4-POLE SENSORLESS BRUSHLESS MOTOR For rentals one week or longer Your Ultimate Rental RALLYE TOUT Copyright © All rights reserved.