Home

ViewTech DT601KP Door Station Install Guide

image

Contents

1. The external power supply must be used according Take off the Jumper to the lock au Es 2 The inside relay contact is restricted to AC or DC 24V 1A The jumper must be taken off before connecting 4 Setup the Unlock Mode of Monitor for different lock types POWER SUPPLY e Power on to unlock type Unlock Mode 0 by default e Power off to unlock type Unlock Mode 1 Unlock parameter setting set in monitor 1 Touch item on main 2 Touch the screen anywhere menu page and hold for 2s 4 A digital keypad and setting 3 Touch Installer setup item instructions will be showed Note 1 must connect DT601 F KP correctly before setting 2 the parameter will be saved in DT601 F KP automatically so you need only set on one monitor 3 the above diagram is fit for icon menu series monitors only to text menu series monitors please refer to the corresponding user manual Be Multi Door Stations Connection 4 Camera 3 Camera 2 Camera 1 Camera Device Address 3 Device Address 2 Device Address 1 Device Address 0 i DIP on offoff A B C D DBC 4S Al OFF T yi I 85 260VAC Impedance switch Multi Monitors Connection Basic IN OUT Wiring Mode ON ON ON ahaha a PATEE AGRO 123456 123456 12345
2. When the item is set to 0 press the x button to cancel the input and press the button to confirm the input When the item is set to 1 press the button to cancel the input and press the button to confirm the input Input the master code Default 1 2 3 4 10 Interference resistant grade setting Default 2 9 Call tone setting Default enable Input the setting code 09 Input the setting code O8 The color of key indicator The color of key indicator yellow Beep Beep yellow Beep Beep 0 1 Inputting of code ex 1 range 0 enable 1 disable 1 Inputting of code ex 3 range 0 5 3 The color of key indicator The color of key indicator green white Beep green white Beep The color of key indicator re white 11 IMC volume adjust setting Default 7 Input the setting code 10 The color of key indicator yellow Beep Beep Inputting of code ex 5 range 0 9 5 The color of key indicator green white Beep Beep Beep 12 SPK volume adjust setting Default 4 Input the setting code 11 The color of key indicator yellow Beep Beep Inputting of code ex 5 range 0 9 5 The color of key indicator green white Beep When the cancel key is pressed the indicator will show its standby color the buzzer beeps and the system exits the setting mode When there isn
3. Inputting of code ex 1006 1 12 digits 1006 The color of key indicator The color of key indicator white 17 Setting the code forTemporary2 18 Setting the code for user group1 20 59 Input the setting code ex 21 21 Input the setting code 19 The color of key indicator The color of key indicator yellow Beep Beep yellow Beep Beep Inputting of code ex 2011 1 12 digits 2010 The color of key indicator 1 12 digits 2011 The color of key indicator Inputting of code ex 2011 Beep Beep 19 Setting the code for user group2 60 99 Input the setting code ex 60 60 The color of key indicator yellow Beep Beep Inputting of code ex 2012 1 12 digits 2012 The color of key indicator green white green white green white Beep Beep green white When the cancel key is pressed the indicator will show its standby color the buzzer beeps and the system The color of key indicator exits the setting mode When there isn t any operation in 10s the indicator will show its standby color the buzzer beeps and the system exits the setting mode When setting failure the color of key indicator will turn red the buzzer beeps The color Beep Beep of standby When input the correct temporary password to release the door the system will clear the temporary password after 60 seconds autom
4. beeps All settings will restore to their default value When power on or activate the reset all setting item the keypad checking will carry out during this time the key illumination will blink and the touching operation is forbidden after finish checking the key illumination will stop blinking and sent out a long sound of beep The master code is allowed 1 12 digits the same code cannot be set to 00 the key illumination will light for both the user code and the master code it is recommended that you modify the default master code up for 10 99 seconds At this mode The unlock time can be set on both monitor and door station and the valid value is the number you set last time If the key illumination time is set up all the time when power on If the key illumination time is set to 10 99 the key illumination will light the key illumination lights off in standby mode touching any digital key can illuminate but this is the invalid digital 10 Input the master code Default 1 2 3 4 5 Setting the unlock mode Default O opened 6 Setting operation tone Default ON Input the setting code 04 Input the setting code 05 The color of key indicator The color of key indicator yellow Beep Beep yellow Beep Beep 0 1 Inputting of code ex 1 range 0 on 1 off 1 0 1 Inputting of code ex 1 range 0 open 1 close 1 The color of key indi
5. ex 1 range 0 a partment 1 villa range Valid keys O 9 O O The color of key indicator The color of key indicator green white green white Beep When the cancel key is pressed the indicator will show its standby color the buzzer beeps and the system exits the setting mode When there isn t any operation in 10s the indicator will show its standby color the buzzer beeps and the system exits the setting mode When setting failure the color of key indicator will turn red the buzzer beeps Work mode setting When the work mode is villa the call O a partment 1 villa address 00 or 16 When the work mode is a partment the range of call address 00 31 52 The color of key indicator The color of standby we Beep Beep PS5 24V Power supply 85 260Vac input 24Vdc 3A Connect with multi doorstations or output 10 DIN modules multi monitors up to 2 or above PS4 24V Power supply 85 260Vac input 24Vdc 1A Connect with one doorstation and one output for basic kit only 4 DIN modules monitor DT16 can be connected two Unlocking of user code When the registered user code has been input using the keypad 1 12 digits the LED background indicator lights up the buzzer sounds and the electric door strike is unlocked note that you should press button if button is set to confirm button after input the unlock code The time interval during which the button
6. must be pressed is approximately 10 seconds If the time interval exceeds approximately 10 seconds the input value will be cleared e If you make a mistake when inputting the user code press the cancel button and input the user code again The release function is forbidden and the input operation is disabled for 60 seconds if 10 times incorrect access codes are continuously attempted During this time the buzzer will continuously sound about 8 times 1 During calling pressing cancel button can cancel the calling 2 If input the incorrect access code the buzzer will sound of beep beep beep sl6 Please clean the unit with soft cotton cloth don t use the organic impregnant or chemical clean agent If necessary please use a little pure water or dilute soap water to clean the dust The unit is weather resistant However do not spray high pressure water on access control keypad directly Excessive moisture may cause problems with the unit You must use the right adaptor which is supplied by the manufacture or approved by the manufacture e Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional Power Supply DC 24V supplied by PS4 24V or PS5 24V Power Consumption Standby 40mA Working status 160mA Camera Color ARS 420 TV Lines Unlocking time 1 99s Lock Power supply 12Vdc 280mA Internal Power Number of relay circuits 2 the second lock ne
7. 2 Wire Video Outdoor Station User Manual DT601 KP DT601F KP DT ENG 601 F KP V1 140526 Contents 1 Parts and FUnetiOnS coimas oss dati fra 1 2 Terminal Description S west 1 s9 DoorStaton MountinGi ennen eren bi 2 4 System Wiring and Connections unseren ASA A SA 4 9 Functions Setting Up sneren A eee ee 8 0 Power Supply INStructONS menner eene AA 16 Unlock Operations viii eee td 16 8 PrecaustiOnS un stervende en inden ebt en ade ee 17 9 Specifications era 17 10 Cables RequirementS ennen neren enneneeneeer ana 18 Camera Lens Speaker Night Light Touch Sensitive Digital Keypad Nameplate Call Button Microphone Rainy Cover Camera Lens Speaker Night Light Touch Sensitive Digital Keypad Nameplate Call Button Microphone Screws for panel mounting DT601F KP Side View Mounting box Lock Control Jumper Main Connect Port Lock Control Jumper To select the lock type Main Connect Port To connect the bus line and the electronic locks BUS Connect to the bus line no polarity PL External lock power input connect to the power positive power S Lock power output Lock power output connect to the power input of locks only when using the door station to power the locks if u
8. 6 Code 15 DIP 6 on Code 14 DIP 6 0 Code 1 DIP 6 off monitor monitor monitor E A IN a CE AF AF A 85 260AC w With DBC 4S Wiring Mode E ON lalalala monitor E cn monitor z ae El 14 DIP 6 Els Impedance Code 15 DIP 6 01 j Code 14 DIP 6 0n aaa mperance oe ol Haloa E Hoj NY ES Fall 2 EH lt EN Es Wo DIP on of off dann monitor Code 13 DIP G on ke un nu nu nu nu nu Li LI nu un nu un nu un nu nm un ON V i ON A GOULED monitor COOLE monitor 123456 i EE 123456 i E Code 3 DIP 6 on 57mm i Code 2 DIPGzon m i Impedance 9FFoN switch m ma a E Holl El ka 2 a O 123456 ijk 208 monitor Code t DIP 6 on A i 85 260AC _ ti Device Address 0 NOTE Here we take DT27 the monitor for example J DIP on off off This section explains the settings of each function please refer to the following table About the setting mode Input the master code to switch to the setting mode and input t
9. atically But you should know that the password is valid within 60 seconds after inputing the correct temporary password The temporary1 is used to release the first lock and the temporary 2 is used to release the second lock the second lock need external device to support If the password length exceeds 12 digits the system will sent out the sound of beep beep beep beep and the digitals you input before will be cleared at the same time The temporary code can not be set the same as the master code and user code The user code group is used to release the first lock and the user code group2 is used to release the second lock the second lock need external device to support The user code group1 and user code code group can contain 40 group passwords If the password length exceeds 12 digits the system will sent out the sound of beep beep beep beep and the digitals you input before will be cleared at the same time The user code can not be set the same as the master code and temporary code 4 Input the master code The color of key indicator Default 1 2 3 4 white Beep Beep 20 Work mode setting 21 Call address setting Default 1 villa Default villa 00 16 a partment 00 31 Input the setting code Input the setting code 100 101 The color of key indicator The color of key indicator yellow Beep Beep yellow Beep Beep Inputting of code ex 1 Inputting of code
10. cator green white Beep green white Beep The color of key indicator oa white 15 Device address setting Default 0 Input the setting code 14 The color of key indicator yellow Beep Beep Inputting of code ex 0 range 0 3 O The color of key indicator green white Beep When the cancel key is pressed the indicator will show its standby color the buzzer beeps and the system exits the setting mode Beep Beep The color of k When there isn t any operation in 10s the indicator will show its standby color the buzzer beeps and the system exits the setting mode When setting failure the color of key indicator will turn red the buzzer beeps Scene0 Standby blue calling Night Light Level 0 5 blue blinks rapidly talking blue blinks slowly unlock green Scene1 Standby green calling green blinks rapidly talking greenblinks slowly unlock blue Scene2 Standby blue calling yellow talking red unlock green the night lights The higher the number the brighter Device address Settings O device address 0 1 device address 1 2 device address 2 3 device address 3 3 ey indicator The color Beep Beep of standby Input the master code Default 1 2 3 4 HH 16 Setting the code forTemporary1 Input the setting code 18 The color of key indicator yellow Beep Beep
11. cator The color of key indicator green white Beep green white Beep The color of key indicator The color of key indicator The color of key indicator white Beep Beep 7 Reset code setting 8 amp function setting Default Normal Input the setting code 06 Input the setting code O7 The color of key indicator yellow Beep Beep yellow _Beep Beep 0 1 Inputting of code ex 1 range 0 normal 1 reverse 1 Inputting of code 1234 The color of key indicator green white Beep green white Beep When the cancel key is pressed the indicator will show its standby color the buzzer beeps and the system exits the setting mode When there isn t any operation in 10s the indicator will show its standby color the buzzer beeps and the system exits the setting mode When setting failure the color of key indicator will turn red the buzzer beeps The unlock mode can be set on When the operation tone is both monitor and door station set to 0 pressing the digital and the valid value is the number keypad will sent out a sound you set last time of beep When the operation tone is set to 1 pressing the digital keypad will blink one time The color of key indicator e Ci The color Beep Beep of standby Cancel all the passwords except the master code Restore the master code to default value 1 2 3 4
12. ed external device to support Mounting Surface mounting DT601 KP Flush mounting DT601F KP Working temperature 15 C 55 C Dimension 182 H x93 W x44 D mm DT601 KP 220 H x120 W x50 D mm DT601F KP 2172 The maximum distance of the wiring is limited in the DT system Using different cables may also affect the maximum distance which the system can reach The farest monitor When Monitor quantity lt 20 Twisted cable 2x0 75 mm 60 60 30 Twisted cable 2x1 mm 80 80 40 When Monitor quantity gt 20 Twisted cable 2x1 mm 70 30 20 Twisted cable 2x1 5 mm 70 50 30 Note lf the monitor has been specified the distance refer to the parameter 18 19 The design and specifications can be modified without notice to the user Right to interpret and copyright of this manual are reserved DT ENG 601 F KP V1 140526
13. he corresponding setting code to perform the settings for the function you want After settings have been made input the following setting codes to continue the setting operation Press X to exit the setting mode The example is set X as cancel button and as confirm button please refer to function setting for detail information Forbid to slide to touch the digital keypad it may cause mistaken key the correct operation is using your finger to press the digital you desired You should press confirm button after finish inputting the code number each time otherwise the operation will be canceled automatically in 10s m 1 12 digits Setting the master code Valid keys 0 9 1234 IEEE 3 Setting the key 10 to 99 seconds 40 Second 02 illumination time continually lit aa ee a T rem E O IMC O en IC a e I CJ grade settings woman mm fe A M ee oe ee emmen wins KR KTM rei rem IK Setting the code 1 12 digits forTemporary1 Valid keys 0 9 Setting the code 1 12 digits oo forTemporary2 Valid keys 0 9 1 12 digits Number of codes 40 Valid keys 0 9 Setting the code for user group1 9 1 12 digits setting he ie oo Number of codes 40 group Valid keys 0 9 Lu Work Mode 0 A partment 1 Villa 1 vi 100 13 14 15 16 17 18 20 21 22 Input the master code Default 1 2 3 41 1 1 Reset all settings Input the setting code 00 The color of key indicato
14. r yellow Beep Beep Inputting of code 1234 The color of key indicator green white _Beep The color of key indicator Inputting of new master code Inputting of code ex 10 ex 4321 1 12 digits The color of key indicator green white _Beep Each operation is indicated by the lighting up of the different color of digital key and nameplate and by the sounding of the buzzer The color of key indicator a white Beep Beep 2 Setting the master code Default 1234 3 Setting the key illumination time Default 10s 4 Setting the unlock time Default 1s Input the setting code 01 Input the setting code 02 Input the setting code 03 The color of key indicator The color of key indicator yellow Beep Beep yellow Beep Beep yellow Beep Beep Inputting of code ex 09 range 01 99 09 range 00 or 10 99 4321 10 The color of key indicator The color of key indicator green white Beep green white Beep When the cancel key is pressed the indicator will show its standby color the buzzer beeps and the system exits the setting mode When there isn t any operation in 10s the indicator will show its standby color the buzzer beeps and the system exits the setting mode The color of key indicator The color Beep Beep of standby When setting failure the color of key indicator will turn red the buzzer
15. sing the external power supply for the locks the S will not be connected DT601 KP Mounting O Drill holes in the wall to match the size of Connect the cable correctly screws and attach the rainy cover to the wall Attach the panel to the rainy cover Use the screwdriver and the screw to fix the panel DT601F KP Mounting Drill a hole in the wall to match the size of the Connect the cable correctly mounting box and attach to the wall 6 Attach the panel to the mounting box and use screws supplied to fix the panel Placing Name Label Use a screwdriver to unscrew the screw and cock the host then Placing Name Label Basic Connection Electric Lock Connection Door Lock Controlled with Internal Power Note R 123 1 Electronic lock of Power on to unlock type 8 4 should be used 2 The door lock is limited to 12V and holding current must be less than 250mA Jumper position in 2 3 3 The door lock control is not timed from Exit Button EB 4 The Unlock Mode Parameter of Monitor must be set to 0 by default 4 Door Lock Controlled with Dry Contact Note 1 2 3 1
16. t any operation in 10s the indicator will show its standby color the buzzer beeps and the system exits the setting mode When setting failure the color of key indicator will turn red the buzzer beeps The larger you set the interference resistant grade the stronger it will be but the sensitivity of the keypad will be more lower The interference resistant grade setting also will activate the keypad checking If the item is set to 0 the unit will respond a call tone when pressing the CALL button If the item is set to 1 the unit will have no responds when pressing the CALL button The color of key indicator The color Beep Beept of standby Unlock via password is still available even when the door station is talking When door station is talking you can enter the Master code the LED turns white upon that to activate the volume adjusting function MIC adjustment 1 up 4 down Sleaker adjustment 3 up 6 down Input the master code Default 1 2 3 41 14 Night light level setting Default 4 13 Display scene setting Default 0 Input the setting code 13 Input the setting code 12 The color of key indicator The color of key indicator yellow Beep Beep yellow Beep Beep 0 1 Inputting of code ex 1 range 0 2 1 Inputting of code ex 3 range 0 5 3 The color of key indicator The color of key indi

Download Pdf Manuals