1.     Press the MODE key at any time during normal    operation to set the current time of the day     e Ifthe EXH icon is blinking  it indicates the exhaust fan    has been on for more than 4 hours or the connection  to the AirCycler   g2 controller was lost     1 0 INSTALLATION INSTRUCTIONS    1 1 CONTROLLER LOCATION  The AirCycler   g2 controller can be installed near the  thermostat or out of view on near the air handler unit     Warning  Before installing the AirCycler    turn off all power to the furnace  There may be more  than one power to disconnect  Electrical shock can cause injury or death     1 2 INSTALLATION EXH OA a A CFM    On power up  all icons willbe  Ret Haa ieee  ON OFF aw    ames  PERIOD    illuminated for 3 seconds    There are two setup methods  Calculated Time and  Calculated Flow  Calculated Flow is used primarily with the  optional FanConnect    bath fan light switch        To set up the AirCycler   g2 based on Calculated Flow  press  the UP arrow within 3 seconds of power up  To setup based  on Calculated Time  press the DOWN arrow within 3 seconds  of power up and skip to section 2 2     Pressing MODE always advances to the next setting    2 1 CALCULATED FLOW SET UP   2 1 1 SETTING MEASURED SUPPLY AIR FLOW   The measured flow is the amount of air that enters the  return side of the air handler from the outside air vent  Enter  the measured flow  To accommodate variable speed air    handlers  you can enter different values for heat  cool and  fan  Fa
2. APPENDIX B   Troubleshooting  Blank Display on the AirCycler   g2 controller     Solution Check    1  Confirm that the furnace has power    2  Confirm that the thermostat is operational    3  Confirm that the furnace will call for heat from the  thermostat    4  Confirm that the fan operates with a fan only signal  from the thermostat   5  Confirm that the furnace is providing 24VAC to the  AirCycler   g2   6  Confirm the wiring conforms to the wiring diagram    7  Make sure the cover is firmly seated on the base    The AirCycler   g2 turns the furnace fan on and off  but   the motorized damper does not cycle    Solution Check    1  Confirm that the AirCycler   g2 is providing a 24VAC  signal to the motorized damper    2  Confirm the 24 VAC motorized damper is operational  by powering directly with a 24 VAC signal   3  Verify there is continuity in the wiring between the  damper and the AirCycler   g2    The A C turns on during fan cycling calls    Solution Check   1  Verify that the wiring conforms to the wiring diagram   2  Confirm that the G wire is properly connected   Note  The G wire must be interrupted by the AirCycler    g2  Do not run the G wire in parallel     The EXH icon is flashing   This indicates the g2 controller has seen the  FanConnect    exhaust fan on for more than 4 hours     Solution Check    1  Turn off exhaust fan    2  Check wiring from FanConnect    switch to g2  controller     For more troubleshooting and frequently asked questions   visit  www airc
3. and C terminals  to be  connected for proper operation  The controller will not  operate without these two connections   Vnc   Normal Closed Vent  R   24VAC Power    W   Heating  Gt   Fan From Thermostat  SS   eS nnn Gf   Fan to Furnace  C  Common  V  Vent  Ex   Exhaust Fan        The wires  R C  amp  W  from the air handler to the thermostat  can run parallel with the wiring from the AirCycler   g2 to  the air handler  The fan wire  G  must be interrupted by the  AirCycler   g2  Some thermostats do not require a common   C  connection  The AirCycler   g2 requires this for power   which must be wired to the furnace     DAMPER LOCATION   The fresh air damper can be located anywhere in the inlet  duct  Minimize the length of the inlet duct to improve air  flow and improve system efficiency  It is recommended  that the damper be as close to the return air plenum and  the AirCycler   g2 controller as possible  and the inlet duct  connect to the return plenum upstream of the system filter   and down  stream of any duct mounted sensors     DAMPER INSTALLATION   The damper may be installed in any position  It is  recommended to install it with the motor at the12 o clock  position if mounted horizontally  Air may flow through in  either direction  although it is recommended to install with  the crimped end as the outlet  Use care to avoid distorting  the damper housing and provide adequate support     CHOOSE A FRESH AIR LOCATION   ASHRAE recommends that the fresh air intake be locate
4. bath fan to run after  the FanConnect    has been turned  off  Factory default is 10 minutes     Press MODE to save all settings and return to normal operation     3 0 NORMAL OPERATION DISPLAY STATUS  amp  SETTINGS    3 1 STATUS   To get detailed status information  press the UP arrow  The  status displays are the same for both Calculated Flow and  Calculated Time modes     3 1 1 MINUTES LEFT    The first display is the number of    minutes left in the period  hour   am  Pressing the UP arrow again gets I AOIR    you to the next status screen    3 1 2 OUTSIDE AIR TIME ELAPSED  This display shows the number  of minutes this period that the  outside air damper has been open  with the central fan running     3 1 3 EXHAUST RUN TIME    This display shows the elapsed  P    run time of the exhaust fan for this  ge  time period     3 1 4 EXHAUST DELAY TIME   This display shows the exhaust  delay time set     3 2 CURRENT SETTINGS   Pressing the DOWN arrow during normal operation  scrolls  through the current setting entered by the installer    For Calculated Time mode    the screens will show     For Calculated Flow mode  the screens will show     Exhaust run time set    Outside air time in minutes   Exhaust fan delay time    If operating time is enabled   Operating Time On  Operating Time Off    Required CFM set   measured outside air CFM   measured exhaust air CFM    exhaust fan delay time    If operating time is enabled   Operating Time On  Operating Time Off      If optional FanCo
5. ctory default is 90 CFM     OT    CH  a PRESS MODE    Flow measured fe CI a   fi       during cooling call          an   am PRESS MODE         Flow measured CI E aM E L am    call aL PRESS MODE    Flow measured  during heat call    during fan only    2 1 2 SETTING MEASURED EXHAUST AIR FLOW  Enter the measured flow    from the         exhaust fan  Factory default is 60 CFM  P  ss P  I 1      Only if FanConnect    is connected LILI    2 1 3 SETTING CODE REQUIRED CONSTANT AIR FLOW    Set the required continuous air flow  lt   in CFM based on relevant codes  For  reaser    I1  ASHRAE 62 2 see Appendix A  Factor  IL  default is 30 CFM  The AirCycler   g2 will   calculate run times based on settings 2 1 1 and 2 1 2     2 1 5 CALCULATED FLOW SETUP IS COMPLETE    Continue to section 2 2 3 Setting the optional mixing time     2 2 CALCULATED TIME SETUP    2 2 1 SET MINUTES HOUR OF SUPPLY AIR REQUIRED  Enter the minutes per hour that  you require fresh air to be brought  into the home  Factory default is 20  minutes  S      OA  r  lt a   SET          fmm  GE     aa    For installations without the FanConnect    switch  go to  section 2 2 3     2 2 2  SET MINUTES OF EXHAUST FAN REQUIRED  Enter the desired minutes per hour jy     hele want the exhaust fan to run  SET aal  a default is 20 minutes per  o LL MIN   HR  our     If the FanConnect switch is not detected  make sure it is in  the OFF position     SLAVE MODE   Press the DOWN arrow until the countdown reaches 0   Press again to get 
6. d  at least 10 ft  from any source of pollutants  such as auto  exhaust  dryer exhaust  exhaust from any fuel burning  appliances  etc  Avoid installation near odor sources such as  garbage bins or barbecue grills  A minimum of 3 ft  above  ground is recommended to avoiding ingress of leaf litter   grass clippings  etc  Do not use a crawl space  basement  or  attic as a source of intake air  Always be sure to comply with  seve building codes and requirements regarding fresh air  inlets     NORMAL OPERATION DISPLAY    THE DAMPER    THE EXHAUST IS OPEN  FAN IS ON    um lmm AM PM    THE THERMOSTAT  HAS TURNED ON   i MIN   HR  THE CENTRAL FAN  EN  PERIOD  PERCENTAGE OF  VENTILATION COMPLETE          THE AIRCYCLER   G2  HAS FORCED THE FAN    e When the AirCycler   g2 is in Normal Operation     the display will show the percentage of ventilation  complete for the current hour     e If the central fan is on  the FAN and ON icon will be    illuminated     e If the exhaust  bath  fan is on  the EXH icon will be    illuminated     e Ifthe outside fresh air damper is open  the OA icon will    be illuminated     e Ifthe exhaust fan is running its delay time after    bathroom occupancy  the delay time countdown  MIN  and EXH icons will be illuminated     e Ifthe thermostat is calling for heat or cool  the FAN    icon will be illuminated without the ON icon     e     The ON icon is only illuminated when the AirCycler   g2    has forced the central fan on   Calculated Time Mode  Only     e 
7. nnect    switch is installed    3 3 1 SET CURRENT TIME   By pressing the MODE key you will cycle through current  time of day and will be able to change it if needed    See 2 2 5   Setting Current Time    3 4 RECORD ALL SETTINGS ON THE INSTALL STICKER  PROVIDED  LIMITED WARRANTY WILL BE VOID IF THE  STICKER IS NOT PRESENT     4 0 RESET TO DEFAULT VALUES  On initial power up when all icons are lit  hold the UP arrow  for 10 seconds to be prompted to reset all settings to default     NO  OF BEDROOMS    WIRING DIAGRAM   Use the following diagram to wire your AirCycler   g2   The controller will not operate correctly if it is not wired  according to the manufacturer   s diagram     Air Handler AirCycler   g2 Thermostat                    Wt Gf Ex                                                                               Follow wiring below for connecting  the optional FanConnect    switch                                              low  Fanconnect         _  TOE   om   switch Blue   Light hot  Black   Hot Bathroom  Creen  Ground Red   Fan Hot S5 Light     Bathroonrs    White   Neutral Fan         White   Neutral    APPENDIX A   ASHRAE 62 2 Reference Chart    For more information about ASHRAE requirements  visit  www ashrae org    SQUARE FOOTAGE    1000 1500 2000 2500 3000 3500 4000 4500       CMF Required  Based on  7 5cfm x  N 1   A x 0 01  N  Number of Bedrooms A   Square Footage    
8. to SL   SL  slave mode  In slave mode the  exhaust fan runs anytime the central fan is running with the  fresh air damper open  Slave mode will provide a    balanced     mode of operation     2 2 3  SETTING THE OPTIONAL MIXING TIME   If the user needs more central fan   time for whole house mixing than rT   the amount that is provided by            J O    ventilation time  the central fan can lon  be configured to run an additional   time period to complete the mixing period  Factory default  is O or OFF     The fresh air damper will not be open during this extra time     2 2 4 SETTING OPERATION HOURS   If the user does not want the ventilation system to run  constantly  n can set ON time and OFF time  Factory  default is OFF    If you are not setting an ON and OFF time  continue to  section 2 2 6     If o enter YES  the AirCycler   g2   will prompt you to enter the hour al  ou would like the ventilation to mme f  egin and the hour you want it to   end followed by the current time     Set the hour you want the ventilation  tine h  i  to START  ON    Set the hour ic want the ae J I a  ventilation to STOP  me pf  2 2 5 SETTING CURRENT TIME  Enter the current time   Hour followed by minutes  SET      PM SET  TIME  L TIME     MIN    2 2 6 CALCULATED TIME SETUP IS COMPLETE  If optional FanConnect    switch is installed  continue to 2 2 7   If not  setup is complete and normal operation will start     2 2 7 EXHAUST FAN DELAY TIME  Set the desired length of time you  would like the 
9. ycler com pages troubleshooting    For Limited Warranty information please visit   www aircycler com products    Technical Support   1 877 FAN CONTrol    LIPIDEX CORPORATION  D B A AIRCYCLER    411 PLAIN STREET   MARSHFIELD  MA 02050   WWW AIRCYCLER COM       AirCycler      Ventilation Products    bdh JE E E E       o o O OO O    AirCycler   g2    INSTALLATION  amp  USER   S MANUAL    VENTILATION MADE BREEZY      A BREEZE TO INSTALL    A BREEZE TO USE     This product may be protected by one or more of the  following patents and patents pending  8185244   7258280  6431268  881806  547017  Canada 2245135    INTRODUCTION  If the AirCycler   g2 was installed in your home as a ventilation  controller  DO NOT DISABLE IT     In the past  homes depended on natural leaks for ventilation   Today  energy efficient homes are built to reduce natural  ventilation and leaks  Inadequate ventilation can increase  indoor air pollutants to harmful levels  Indoor air quality  is typically 5 to 10 times more polluted than outside air   Controlled ventilation provides adequate air flow to the  home without compromising its efficiency     SAFETY CONSIDERATIONS   Read and follow manufacturer s instructions carefully   Follow all local electrical codes during installation  All  wiring must conform to local and national electrical codes   Improper wiring or installation may result in personal injury  or product and property damage     INSTALLATION CONSIDERATIONS  The AirCycler   g2 requires 24VAC  R 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
LactiWhey-Spanish-Web copy - Page & Pedersen International ltd.  portada 5. pmd - Diputación de Alicante  Manual Flytec 6000  G3046 LTS-D DE-GB-FR-ES-IT  P`tit communiqué 2e trimestre 2015  LG WM8000HVA Product manual  Service Manual SurgiPro-EN  常圧式土練機  TMS320C6000 Optimizing Compiler User's Guide (Rev. L)    Copyright © All rights reserved. 