1.     PREPARE  OPERATE    REL  ON ONE CHAIR    UFSK    INTERNATIONAL    1  Device Safety       The medical device described in this manual was developed in full compliance with all national and  international safety regulations  We guarantee through a rigorous series of tests and inspections that  every device meets or exceeds the highest quality standards    We want to ensure that you are well informed of all relevant safety and handling recommendations  and precautions before using this device  This chapter contains the most important technical safety  information regarding this surgeon   s chair     Safety information of critical importance is contained within text boxes like the one seen here     Please give special attention to this information        Proper usage of this device is essential for both operator and patient safety  To avoid any accidents  resulting from negligence or misuse  please thoroughly familiarize yourself with the contents of this  manual  Please also carefully read through the service manuals of any other equipment or devices  that will be used with this product  Supplementary information can be obtained from our service staff  or authorized representatives     2  Standards and Regulations    e The medical device described in this manual was constructed in compliance with  the following regulations  where applicable       EN     IEC   e In correspondence with regulations or guidelines of each country  this device may  have to be connected to a    Spe
2.   1060hPa  Ambient Conditions  For transport and storage  in shipment packaging  Temperature  40T     70T  Rel  Humidity 10    100   without condensation   Air pressure 500hPa   1060hPa    We reserve the right to alter or modify the construction of this product and included parts at any time     11  Important Note    The following items are excluded from the warranty    gt  All upholstery elements    Paintwork defects     gt    gt  All damages suggesting inappropriate operation of the equipment by the user    gt     Batteries  12  GF  Jurgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500    VAT No  DE232257366 Kto Nr  32 92 935  HRB 9186    REGISTERED FIRM       PREPARE  OPERATE    RELAX    UFSK    _ ON ONE CHAIR       INTERNATIONAL       12     Declaration of Conformity    hereby  we  UFSK International OSYS GmbH  Kirchhoffstra  e 1  93055 Regensburg  Germany  declare on our own authority  that the product    Surgeon   s chair  Model surgiPro  is conform with the following conformity assessment procedure    attachment VII    according to the rules of the directive 93 42 EEC of the council dated 14  June 1993 for Medical  Devices  last amendment by directive 2007 47 EC of the European Parliament and of the Council of 5    September 2007   Mn N    J  rgen Scherrieble  General Manager       This declaration is no longer valid if any change on the products will be made without our written  confirmat
3.   The voltage settings of this device are compatible with the rated voltage of power outlets  at the installation site      While in use during a surgery  this device must not be plugged into any power outlets  if so the  emergency stop button should be engaged      The device must be plugged in with the specifically provided power cable        REGISTERED FIRM    UFSK    INTERNATIONAL    3 4 Every time before use or after alteration or modification of this device       GF  Jurgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935    HRB 9186    PREPARE  OPERATE    REL  ON ONE CHAIR       e Make sure that all requirements for use are met    e Go carefully through the checklist    e Refasten any removed housing  panels or screw caps  Properly close all remaining  covers    e Check that the power plug is securely seated    e Check that the plug of the footswitch plate  optional  is also securely seated     3 5 Every time after using this device    e Use the emergency stop button to turn this device off   e The emergency stop button must always be engaged when this device is not being  used     4  Device Description    This state of the art surgeon   s chair is ergonomically designed to help the surgeon  comfortably and effortlessly maintain correct posture  facilitating improved endurance and  enhanced concentration during surgery     This surgeon   s chair has man
4.  place   11    GF  J  rgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935    HRB 9186       REGISTERED FIRM       PREPARE  OPERATE    REL  ON ONE CHAIR    UFSK       INTERNATIONAL    9  Accessories       Please note  Use this device only with accessory parts that where included in your shipment  If you  would like to use other accessory parts with this device  please confirm all relevant safety and  compatibility requirements with the parts manufacturer     10  Technical Specifications    Base Area  630mm x 765mm  max     Armrests  With joints adjustable in all directions    Backrest  Adjustable in height and inclination   Seat Height  min  553mm  max  753mm    Seat Height adjustment  Electromotive  Lifting 200 mm    Arm Supports   Height adjustment  Electromotive  Lifting 200 mm    Chassis  Central brake effective on all four double wheel casters  One of the  casters has anti static protection    Weight  60kg   Power supply  100 110 120 125 230 240 V   10    Nominal Frequency  50   60 Hz   Power input  12VA   Short term load  Lifting column   2min    Height adjustment for arm supports   2min    Power fuse rating  250V T2 5A  Electrical Specs  According to IEC 601 1 EN 60 601 1   VDE 0750  Parti  Protection  class 1  Type B  Degree of protection IPX4    Ambient Conditions  For Operation  Temperature  10T     40T  Rel  Humidity 30    75   Air pressure 700hPa 
5. NTERNATIONAL       GF  Jurgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935    HRB 9186    PREPARE  OPERATE    REL  ON ONE CHAIR        plugs  sockets   If you are having difficulty with a connection  be sure to double check  that the plug and socket match  If you determine that the plug connection is damaged   please let our service team perform any needed repairs    e Potential Equalization  Upon request  this device can be adapted with the required  safeguards for    Potential Equalization     Please inform our service staff if this is  desired    e Do not use cordless or cellular phones near this device  These kinds of phones are  potentially dangerous for the proper functioning of medical devices  Unexpected  malfunctions can appear depending on a number of on site factors  These malfunctions are  neither predictable nor assessable beforehand    e Modifications to this device or any devices to be used with this device may only be  performed by our service staff or authorized personal    e We will not be held liable for any damages resulting from the unauthorized use or  modification of this device  Any unintended use or modification of this device will  immediately void all manufacturer warranties    e Use this device only for its described intended purpose    e Use this device only with accessory parts that where included with your shipment  If you  w
6. PARE  OPERATE    RELAX    UFSK       ON ONE CHAIR    INTERNATIONAL    6 3 Changing Power Fuses       Diagram 4       When changing power fuses  please follow these instructions     e Make sure that the device is not plugged into a power outlet   e Remove all necessary screws and panels  8  and then take out the defective fuses   e Install the new fuses and then replace and secure all previously removed panels and screws  8      Please Note  Pay careful attention to the fuse ratings  The correct ratings can be found on the  device rating plate     7  Surface Cleaning    All parts of this surgeon   s chair can be wiped clean with a damp cloth  The use of aggressive or  abrasive cleaning agents should be avoided    Wipe away possible residues with a mix of equal parts alcohol and distilled water  and a spritz of  commercial quality detergent     8  Changing Functional Location    Following these instructions when changing the functional location of the surgeon   s chair     Engage the emergency stop button  8     Press down the green pedal  9 1  to release the brakes     Make sure there is sufficient space when moving the chair through doors or narrow passages     Avoid any kind of bumping  shoving or jolting     Do not move this chair over thresholds  steps or uneven surfaces     Move this chair over inclined surfaces with great caution     Do not park this chair on an inclined surface     When the new location has been reached push the brake pedal  9 2  to secure the  chair in
7. PREPARE  OPERATE    REL  ON ONE CHAIR    UFSK       INTERNATIONAL       User Manual Surgeon   s chair  SurgiPro    Version 12 11       Product shown with optional accessories    1  GF  Jurgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935  HRB 9186       REGISTERED FIRM    PREPARE  OPERATE    REL  ON ONE CHAIR           UFSK       INTERNATIONAL       Table of contents    1  Device Safety    2  Standards and Regulations    3  Safety Precautions for Installation and Usage   3 1 General   3 2 Safe Operation   3 3 Requirements for Use   3 4 Every time before use or after alteration or modification of this device  3 5 Every time after using this device    4  Device Description   5  Preparation   Device Operation   5 1 Charging the integrated batteries  5 2 Surgeon   s Chair Adjustments   5 3 Adjusting the arm rests   5 4 Checklist   5 5 Operating Procedure   6  Device Maintenance   Miscellaneous  6 1 Safe Operation   6 2 Malfunction Troubleshooting Table  6 3 Changing Power Fuses   7  Surface Cleaning   8  Changing Functional Location   9  Accessories   10  Technical Specifications   11  Important Note    12  Declaration of Conformity    13  Maintenance    GF  Jurgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935   HRB 9186       REGISTERED FIRM
8. The plug on the power cord  6 1  should only be connected with a matching power outlet  that has proper grounding protection     Power fuses  The correct fuse ratings can be found on the device rating plate  Instructions for changing  the power fuses can be found in chapter 6 3     Emergency stop button  8     The electrical supply of the surgeon   s chair can be turned on and off here     Brake Pedal    Push down the red brake Pedal  9 2  with your foot to secure the chair firmly in place   Pushing down the green pedal  9 1  releases the brakes and the chair is once again  moveable     10  Footswitch Plate Adapter  Optional     11  Charging Indicator    Diagram 2       GF  Jurgen Scherrieble    Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935    HRB 9186    Deutsche Bank Regensburg SWIFT  DEUTDEDB750       REGISTERED FIRM    PREPARE  OPERATE    RELAX    UFSK     gt    ON ONE CHAIR       INTERNATIONAL       Diagram 3       4 1  1 1  4 2  1 1  11  7  GF  J  rgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935    HRB 9186       REGISTERED FIRM    PREPARE  OPERATE    RELAX  ON ONE CHAIR     gt           5  Preparation   Device Operation  5 1 Charging the integrated batteries     Diagram 3   e Plug the power cord into the charging socket on the chair  6  and the other end into  a power outlet  The charg
9. cial power supply     BEV     e This product is a class 1 medical device in accordance with 93 42  EWG    e The declaration of CE conformity contained within this service manual is only valid for  new devices that come delivered with this manual  The declaration in invalid for old or  used devices without the CE symbol    e Please be aware of all legal requirements for accident prevention     3  Safety Precautions for Installation and Usage  3 1 General    e Do not electrically operate any of the devices included in your shipment      In areas that are exposed to the danger of explosions     Inthe presence of flammable anesthetic or volatile solvents such as alcohol  gas or  similar substances    e Do not use or store this device in a damp room  Keep dripping  flooding or  splashing water away from this device    e Immediately pull the power plug if you notice any smoke  sparks or unusual smells  coming from your device  Do not use the device again until after it has been  examined and repaired by a member of our service team    e Do not place any liquid filled containers on this device  Make sure that no liquids can  enter into electrical components of the device    e Do not use excessive force when plugging in electrical components of this device    3    GF  Jurgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935   HRB 9186       REGISTERED FIRM    UFSK    I
10. ing indicator  11  will light up green  indicating that the    batteries are being charged  If the charging indicator  11  does not light up  check  to see if the emergency stop button is engaged  8      5 2 Surgeon   s Chair Adjustments    e Release the emergency stop button  8      CAUTION     Watch out for crush hazards when adjusting the surgeon   s chair downwards        Please Note  Electromotive up down adjustment of this surgeon   s chair and arm supports is only  designed to be run for a limited duty cycle  Thermal problems can arise if the motors are overrun  or overloaded     e To adjust the backrest  4  upwards or downwards  Loosen the star knob screw  4 1  and move  the backrest to the desired height  then retighten  4 1     e To incline the backrest  4  forwards or backwards  Turn the star knob screw  4 2  and until the  desired position is reached     5 3 Adjusting the arm rests       GF  Jurgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935   HRB 9186       REGISTERED FIRM    PREPARE  OPERATE    RELAX  ON ONE CHAIR          C  Screw B  rew C  Step 1  Loosen Screw A  Safety Screw    Step 2  Screw B adjusts the tightness of the lever that locks the ball and socket joint in place       Loosen Screw B until the lever is resting on the plate     Step 3  The C Screws adjust the load bearing capacity of the armrest   Tighten screws   firmer load bea
11. ion     Regensburg  01 05 2011    13    GF  J  rgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935   HRB 9186       REGISTERED FIRM    PREPARE  OPERATE    RELAX    UFSK      ON ONE CHAIR     gt        INTERNATIONAL    13  Maintenance       For technical inquiries  customer service isSues and spare parts orders  please contact us at     UFSK International OSYS GmbH  KirchhoffstraBe 1  93055 Regensburg  Germany  Tel   49 941 78862 15  Fax   49 941 78862 35  e mail  info ufsk osys com   www ufsk osys com    14  GF  Jurgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935  HRB 9186       REGISTERED FIRM    
12. ould like to use other accessory parts with this device  please confirm all relevant  safety and compatibility requirements with the parts manufacturer    e This device may only be operated by persons with the appropriate experience level or training  It  is the duty of the device owner operator to make sure that all potential users are adequately  educated and trained before being allowed access to this device    e Please make sure that this service manual is readily available at all times for users    e Please do not pull on the power supply cable or any other cable connections    e The power plug may only be connected with a power outlet that has proper grounding protection     3 2 Safe Operation    e This product is a premium grade technical device  In order to ensure its flawless and safe  functioning  we recommend that you allow our technicians to perform routine service and  maintenance  If an error occurs that you cannot solve with the help of the malfunction  troubleshooting table  please label the device as non operative and contact our service  staff immediately     3 3 Requirements for Use    Our service staff or a skilled professional recognized by our company will install your  device  Please make sure that the following requirements for use are met       All connecting parts described in this service manual  that ensure the safety and security of this  device  are properly seated  screwed in and tightened      All cables and plugs are in excellent condition    
13. ring  Loosen screws   softer load bearing  The C Screws must be quarter turned in parallel until the desired load bearing level is    reached   Testing is possible only after all screws have been adjusted    Step 4  Tighten Screw B in such a way that the locking lever generates sufficient counter  pressure    Step 5  Tighten Screw A     5 4 Checklist    Check the following points every time before use  without patient      e The power cord is not connected to an on site power outlet   e The emergency stop button is  8  engaged   e The chair is adjusted in a comfortable and supportive position for your body     CAUTION   For safety reasons the chair must not be used if any of its functions fail  If possible  diagnose and    fix any problems yourself  using the malfunction troubleshooting table in chapter 6 2  or  contact our service team as soon as possible        GF  J  rgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500  VAT No  DE232257366 Kto Nr  32 92 935   HRB 9186       REGISTERED FIRM    PREPARE  OPERATE    REL  ON ONE CHAIR    UFSK    INTERNATIONAL    5 5 Operating Procedure       e Inspect the surgeon   s chair using the checklist    e Move the surgeon   s chair to the location where it will be used    e Engage the brake pedal  9 2  to secure the surgeon   s chair in place    e  f necessary  readjust the seat height to ensure the correct distance from the foot controls  and  then readjus
14. t the backrest and armrests    e The emergency stop button  8  must be engaged if the surgeon   s chair is not being used     CAUTION     The batteries are not being charged if the emergency stop button is engaged        6  Device Maintenance   Miscellaneous  6 1 Safe Operation    This product is a premium grade technical device  In order to ensure flawless and safe  functioning  we recommend that you allow our technicians to perform routine service and  maintenance     6 2 Malfunction Troubleshooting Table    If an error occurs that you cannot solve with the help of the malfunction troubleshooting table  please  label the device as non operative and contact our service staff immediately     MALFUNCTION POSSIBLE CAUSE SOLUTION  adjustment of the chair Contact Service Staff    does not function     Emergency stop button is engaged Release    Battery charge is low Contact Service Staff    Defective lifting column Contact Service Staff    Defective control box Contact Service Staff  Electromotive height Defective joystick Contact Service Staff  adjustment of the arm  Supports does not function  Emergency stop button is engaged  Battery charge is low Contact Service Staff       Defective drive Contact Service Staff  Defective control box Contact Service Staff  10  GF  J  rgen Scherrieble Deutsche Bank Regensburg SWIFT  DEUTDEDB750  Steuernummer 244 140 60001 BLZ 750 700 24 IBAN  DE94750700240329293500    VAT No  DE232257366 Kto Nr  32 92 935  HRB 9186       REGISTERED FIRM    PRE
15. y features including      Independent electromotive height adjustment for arm supports    Continuous angle and inclination adjustment for armrests     Comfortable seat with height adjustable backrest      Electromotive seat height adjustment     Footswitch plate adapter  optional     1  Articulating joints of the armrests  The articulating joints enable full armrest adjustability in any desired direction  For making    adjustments simply loosen the release lever  1 1   Using the foot joystick  1 2  you can perform  electromotive adjustment of the arm supports     2  Armresis  The armrests can be easily inclined and turned in any direction  Using levers  2 1   2 2  the swivel  angle of the armrests can be quickly adjusted     3  Foot switch to adjust seat height  The desired seat height from 530 to 730 mm can be adjusted with electromotive power using the    footswitches  3 1   3 2   The left footswitch  3 1  from the surgeon   s perspective moves the chair  upwards  The right footswitch  3 2  from the surgeon   s perspective moves the chair downwards     4  The Backrest  The backrest can be adjusted in inclination and height  Loosen the star knob screw  4 1  and  adjust the backrest to the desired height  For inclination turn the star knob screw  4 2  left or  right     5  Device Rating Plate  Contains the electrical specifications and ratings of the device        REGISTERED FIRM    UFSK    INTERNATIONAL       PREPARE  OPERATE    RELAX       _ ON ONE CHAIR    The power cord  
    