1. Fig 2 Fig 3 1 WARNINGS FOR THE INSTALLER Read the warnings contained herein with care as they furnish important instructions regarding safe use installation and maintenance After removing the packaging check the condition of the unit The system must be installed in compliance with current safety standards The manufacturer declines all liability for any dam age as a result of improper incorrect or unreason able use Should the unit be in need of repair contact only a technical support centre authorized by the manu facturer Failure to comply with the above instructions may compromise the unit s safety 2 LOCATION OF TERMINAL Install the unit on an internal wall fig 1 in a position which is suitable for correct measurement of the room temperature avoiding installation in niches behind doors or curtains or near heat sources fig 2 3 INSTALLATION OF THE TERMINAL Open the unit by using a screwdriver in the slot fig 3 Fasten the base to the wall using the screws and dowels provided or on a recessed box fig 4 We rec ommend you install it on a flat surface being careful not to over tighten screws Connect the wires ofthe non polarized twisted pairs to the terminals of the provided connector and insert it on the printed circuit fig 5 Close the unit After connecting the various system devices con nect the p
2. OH T 01 Basic interface User s manual OH T 01 Basic interface User s manual PROGRAMMING AND CONTROL TERMINAL OH T 01 The unit allows you to control and activate the main building services in a HOASIS home automation con trol system The HOASIS home automation control system is composed of two main units the OH T 01 program ming and control terminal and an OH A activation and power supply unit The system manages up to 64 relays and 71 contact inputs including 7 ofthe OH Z zone modules The terminal makes it possible to program the tem perature and to manage lights irrigation systems automation devices etc In thermal adjustment mode the unit combines vari ous functions summer winter anti freeze pre set programmes date and time display 09 35 TE Bedroom 16 0 c bpt In home automation operation mode it allows the control of relays with timers scenarios or activations commanded by the user The touch screen technology makes it possible to set all parameters and programming just by touching the icons on the display On line help guides the user through the program ming of the various functions Communication between the various units in the sys tem takes place by means of a bus realized on a sin gle twisted pair 1 DESCRIPTION 9 1 Pen for touch screen 2 Go back to previous menu 3 Display touch screen 4 Canc
3. 22 SCENARIOS 9 Control of Scenarios nu 23 TIMERS 10 Control of tiMers iii 24 11 Activation of pre set scenarios 25 HOASIS HOASIS Fri 12 May Fri 12 May bot OH T 01 OH T 01 Basic Interface Interface Plus Installer instructions Installer instructions CHAPTER Page CHAPTER Page 1 Warnings for the installer 28 1 Warnings for the installer 42 2 Location Of terminal 28 2 Location of terminal s is 42 3 Installation of the terminal 28 3 Installation of the terminal A Setting the clock i 30 4 Installing the Hoasis Plus interface 5 Configuration and programming of air 5 Useful information a conditioning ZONES 30 6 Technical characteriStiCS 46 6 General settings of the air conditioning Systema Lioni niaianinaluziata 33 6 1 Advance activation 33 6 2 manual temperature variation on the OH Z therMostats iu 33 7 Configuration of zones of home automation control 8 Choice of inputs 9 Function of inputs 35 10 Modification of home automation control zones 10 1 Cancellation of home automation control ZONES ns 37 11 Useful information 12 Technical features
4. Unit for civil use Back lit LCD touch screen display Power supply from bus line BUS line specifications The cable provided must be a twisted pair shield ess and non polarized t is important to keep in mind that if you use the wisted pair telephone line compliant with CEI 46 5 which is not insulated for the voltages being used it must be placed in special ducts that is not used for wiring at a voltage of 230 V AC Anti freeze temperature 8 C Field of adjustment from 2 to 35 C Room temperature measuring interval 30 seconds Reading resolution 01 C Displayed field of reading from 0 C to 35 C Precision lt 0 5 C Pollution situation normal aximum temperature of control head 40 C Protection rating IP30 Operating temperature from 0 C to 35 C Dimensions 116x95x27 mm 46 OH T 01 interface plus Installer s Manual 47 bpt bpt WARRANTY TERMS AND CONDITIONS 1 Purpose of the warranty Without prejudice to the rights the Consumer is enti tled to according to the provisions of article 1519bis and following articles of the Italian Civil Code with respect to Dealers and Installers BPT warrants that its audio and video entry control thermoregulation and CCTV equipment will be in conformity with the description given of each in the technical literature supplied with the relevant equipment The warranty covers a
5. bpt technological sign Instructions for user and installer for control and programming terminals HOASIS E 2 12 08 20 2 Fri 12 May DEE OH T 01 ti Basic Interface HDASIS Herdas 12 08 20 2 Fri 12 May OH T 01 bet Interface Plus 07 2006 24081022 Congratulations on your purchase of an OH T 01 control terminal for the Hoasis system will allows you to manage the automation in your home The terminal lets you manage two types of functions on the display which are called Basic Interface and Interface Plus You can upgrade the terminal from the Basic to the Plus version by contacting a qualified installer Therefore this manual is divided into two parts Each part illustrates the special fea tures and functions of the two available versions of software and the corresponding interface To get the most out of this unit and to take full advantage of its characteristics and functions please carefully read this manual and keep it available for future reference The OH T 01 Terminal is equipped with a bag of accessories containing dowels screws pens and connector for connection The instruction booklet includes a warranty certifi cate for any repairs which the unit may require b Pt Index HOASIS HOASIS Be 12 08 20 2 c 12 08 20 2 Fri 12 May Fri 12 May La Es OH T 01
6. fy the days of activation of the timers press on the key for the selection of activation time The list of activa Press on ions wil By selec he time From th ions for the selected timer is shown the Activation key The list of timer activa appear fig 25 ing one of these up to 4 activations per day it is possible to set the interval of operation of F Upon completion of this operation press OK to go back to the previous menu e list of timers to go back to the initial screen press the key Home or the key OK 24 OH T 01 interface plus EE DOGS Climate Opening Scenarios Timers 12 08 20 2 Fri 12 May SCENE SCENE SCENE Fig 26 User s manual 11 ACTIVATION OF PRE SET SCENARIOS If functions have been matched to the three scenar ios during installation pressing on one of these icons in the main menu activates all corresponding func tions Note The preset scenarios are configured by the installer and cannot be modified by the user 25 Since the terminal can be upgraded to the Plus version by a qualified installer the sec tion of the manual for installation has been divided into two parts Each part illustrates the procedures to be followed for proper installa tion of the two versions of the device 26 OH T 01 Basic interface Installer s Manual OH T 01 Basic interface Installer s Manual AA Fig 1
7. fig 3 Fasten the base to the wall using the screws and dowels provided or on a recessed box fig 4 We rec ommend you install it on a flat surface being careful not to over tighten screws Connect the wires ofthe non polarized twisted pairs to the terminals of the provided connector and insert it on the printed circuit fig 5 Close the unit After connecting the various system devices con nect the power supplier OH A 01 to the local net work After 20 seconds the terminal display will show the main menu fig 6 Fig 2 Fig 3 42 OH T 01 interface plus bet Installer s Manual WARNING For correct programming of the terminal proceed as follows Fill out the tables included with the power supplier OH A Set the clock Install and program the climate control zones Install the home automation control zones 43 OH T 01 interface plus Installer s Manual Prova_programmazione e e e e e e e e 4 INSTALLING THE HOASIS PLUS INTERFACE In order to install the Hoasis Plus interface on the terminals OH T 01 or OH T it is necessary to use a PC with the PC HOASIS software installed and to con nect to the system using the interface IPC OH After launching the installation programme choose a system name and language fig 6 Then create the system structure fig 7 In the menus for thermosta
8. 9 The display will show the menu as in fig 11 Select he day and the zone from which to copy and trans er the desired profile Press OK to confirm the operation The display will show the message COPIED to confirm the operation Press End to go back to the previous menu 3 2c Setting temperature levels To modify the 3 temperature levels press on the icon 4 LEVELS fig 9 The display will show the menu as in fig 12 Select one of the 3 levels and press on or V to modify the value After confirmation you will return to the menu with the list of the days of the week WARNING In MANUAL or AUTOMATIC operation if the relay relative to the zone is active on the left hand side of the menu figures 6 7 the message ON appears When the relay is not active the message ON is not present OH T 01 Basic interface Bedroom gt EE un 16 0 RERBENEC LI I I SI Tuesday C Bathrooms User s manual 4 GENERAL SETTINGS OF THE AIR CONDITIONING SYSTEM From the main menu fig 2 press on the icona Tj then on the next menu press 4 the menu General settings will appear From this menu you can select the system operating mode COOLING SUM MER HEATING 4 WINTER fig 13 All climate control zones can be deactivated by pressing on the icon OFF WARNING After selecting one of the two system operating modes all of the climate control zones are deactivated con OH T 01 OFF
9. OH T 01 Basic Interface Interface Plus User instructions User instructions CHAPTER Page CHAPTER Page 1 Descriptionis sss ss eme 6 1 DEScriptio Nunez 6 2 Setting the clock 7 2 Setting the clock 7 3 Temperature setting i 7 CLIMATE 3 1 Manual operation 3 General Settings 7 3 2 Automatic operation 4 Temperature setting 8 3 2a Pre set heating and cooling programmes 8 4 1 Manual operation 8 3 26 Modification of programs 8 4 2 Manual operation 3 2c Setting temperature levels 0 timed Holiday programme 8 4 General settings of the air conditioning 4 3 Automatic Operation 9 SYSTEM RR O TT 1 4 3a Pre set heating and cooling 5 Locking commands for zone temperature DOUANES incorre 9 CONtrOl 1 4 3b Programme modification 9 6 ANtI f 00Ze ciccia 1 4 3c Setting temperature levels 20 7 Display of air conditioning ZONES 2 5 Locking commands for zone temperature 8 Display of installed home automation zones 12 CON nn 21 9 Setting operation of home automation 6 Anti freeze Lin 21 ZONES ete 2 LIGHTS 10 Timer programming and modification 3 7 Control OF LIGHTS ini 22 11 Activation of Scenarios 3 OPENINGS 8 Control of OpeniN Ss
10. ions assigned to it during the installation phase Using the ON and OFF keys fig 22 you can exclude or include the activations connected to the scenario To view other activations connected to the scenario up to 10 press on the arrows at the bottom of the dis play To go back to the list of scenarios press the key Home or the key OK From the list of scenarios to go back to the initial screen press the key Home or the key OK 23 OH T 01 interface plus User s manual GA Friday 09 35 Irrigation A O 4 C Fig 23 Friday 09 50 WEDNES THURS INIONIPYAZAI TUESDAY FRIDAY Fig 24 A Friday 09 55 f to rom Activation 02 00 04 00 Activation 06 00 08 00 Activation 00 00 00 00 Activation 00 00 00 00 Fig 25 bpt TIMERS 10 CONTROL OF TIMERS From the main menu fig 17 press on the Timer The display will show the list of the first 4 timers up to 40 insta Iled in the Hoasis Plus system fig 23 Key for selection of day of activation O Key for selection of time of activation to view 4 more installed timers press on the arrows at the bottom of the display Timers in operation are shown with the name in bold face fig 23 To modi fy the days of activation of a timer press on the key for the selection ofthe days of activation and select or To modi de select the desired days fig 24
11. menu it is possible by pressing on the name of the involved zone to access the menu where the settings you have made can be modified For this operation follow the instructions in chapter 3 8 DISPLAY OF INSTALLED HOME AUTOMATION ZONES From the main menu fig 2 press on the icon Q The display will show the list of the first four zones service maximum 32 without climate control zones that the home automation system controls fig 16 Press on to display the other zone services This information will be shown after carrying out the programming procedure When the name of the zone is highlighted it means that the relative relay is active 9 SETTING OPERATION OF HOME AUTOMATION ZONES Press on one of the zones included e g Bedrooms in the list in fig 16 to display the menu in fig 17 By pressing on the icon OFF or ON it is possible to force the exclusion of the zone thus deactivating the functions programmed at installation NOTE When controlling the OH MA modules the forcing function TURNED OFF by the OH T 01 termi nal does not disable local controls or other pro OH T 01 Basic interface 09 50 GA Friday HOME WEDNES THURS porn en DAY DAY FRIDAY SATUR DAY Fig 19 Cancel Friday 09 55 from to 02 00 04 00 06 00 08 00 00 00 00 00 Activation 00 00 00 00 Cancel Fig 20 DOMO Activation Activation Activation T TEMP Tue 30
12. on OH Z 5 LOCKING COMMANDS FOR ZONE TEMPERATURE CONTROL From the main menu fig 2 press on the icon Ey The display will show the list of the first four zones max imum 8 in which the climate control system is installed along with the relative temperature and operating mode fig 15 Press on to display the other 4 possible zones Select the desired zone and press on icon BLOCK fig 14 to deactivate the commands which can be given from the OH Z control module 6 ANTI FREEZE During the winter if the temperature drops below 8 C the terminal will automatically activate the anti freeze function This occurs even if the zone is off OH T 01 Basic interface User s manual A Tuesday HOME C Bathrooms C Kitchen C Living room Fig 16 AS 09 50 Bedroom AUTO Fig 17 eG Friday 09 50 EME Bathrooms Timer 01 JUL ACTIVAT bpt 7 DISPLAY OF AIR CONDITIONING ZONES From the main menu fig 2 press on the icon Tj The display will show the list of the first four zones maximum 8 in which the climate control system is installed along with the relative temperature and operating mode fig 15 Press on to display the other 4 possible zones This information will be shown after carrying out the programming procedure When the name of the zone is highlighted it means that the system is in operation the relative relay is active NOTE From this
13. pressing on the icon D 6 1 ADVANCE ACTIVATION This function makes it possible to start the climate control system in order to have the desired temper ature at the set time Press on the icon fig 16 to activate icon high lighted or deactivate the function 6 2 MANUAL TEMPERATURE VARIATION ON THE OH Z THERMOSTATS When programming the heat zones it is possible to increase the manual temperature variation limit on the OH Z thermostats from 2 C default to 8 C by pressing on the icon 28 in the menu General Set tings fig 16 After modifying the limit of manual temperature variation it is necessary to vary from OH T the man ual temperature or status of each single heat zone in order for the modification to take effect Press again on OK to go back to the climate control zones menu fig 17 You can now set the temperature for each single zone and decide the type of operation AUTOMATIC MANUAL SYSTEM BYPASS 33 OH T 01 Basic interface Installer s Manual Password The system detects 04 inputs and 04 relays Continue 7 CONFIGURATION OF THE HOME AUTOMATION CONTROL ZONES From the main menu fig 6 press on the icon The display will show the list of zones installed in the home automation system temporarily empty fig 18 since the names of the installed zones will be displayed after carrying out the programming procedure Then press on the i
14. the duly filled out and stamped as above certificate together with the invoice for its installation or invoice receipt of pur chase 50 bpt Do not litter the environment with packaging mate rial make sure it is disposed of according to the reg ulations in force in the country where the product is used When the equipment reaches the end of its life cycle avoid discarding in the environment The equipment must be disposed of in compliance with current regulations recycling its component parts wherever possible Components that qualify as recyclable waste feature the relevant symbol and material acronym DI E z Al WARRANTY CERTIFICATE Fill out and attach to the unit for repairs bpt BPT S p A 30020 Cinto Caomaggiore VE Italy UNIT USER MODEL SERIAL N DEALER STAMP ADDRESS STREET No ZIP POSTCODE CITY DATE OF PURCHASE STATE COUNTY TEL technological sign BPT S p A Via Roma 41 30020 Cinto Caomaggiore VE Italy info bptit www bpt it 52
15. 01 interface plus Good night Wake up Party Video Ga Friday 09 35 Yard lights Patio lights o Irrigation Laundry User s manual To activate one of the opening on the list in a direc tion or in the opposite direction you only need to press on the keys A or Wfor the corresponding opening Once you have pressed the opening or closing button it will be activate for a length of time as established during system installation During activation the arrow that corresponds to the activated direction will be highlighted on the dis play To stop activation press on the key with the oppo site direction of the active one bold face arrow on screen To go back to the initial screen press the key Home or the key OK SCENARIOS 9 CONTROL OF SCENARIOS From the main menu fig 17 press the icon SCENARIOS The display will show the first four avail able scenarios up to 16 installed in the Hoasis Plus system fig 20 To view other scenarios press on the arrows at the bottom of the display To activate one of the scenarios on the list press the corresponding ON key You can also modify the sequence of actions activat ed in each single scenario f you press on the key showing a spanner F the ist of scenarios will be shown again f you press the Modify key located alongside the sce nario name fig 21 you will be shown the list of activa
16. 6 hours is shown fig 11 To modify the profile scroll the flashing cursor by pressing on Z or P until the time is reached for which you wish to change the temperature shown on the display at upper right Press on one of the three squares for the temperature level to set the desired value NOTE Programming is carried out in intervals of 15 minutes Using only Z or gt after de selecting any levels which may have been selected you can scroll through a profile to check it After confirming the modifications you have made you will go back to the menu with the list of the days of the week If you want to copy a profile from one day of the week to another press the icon COPY fig 12 The display will show the menu as in fig 13 select the day and the zone for copying in the upper right part of the window Then select the destination day and zone in the lower part of the window and press OK to carry out the operation The display will show the message COPIED to confirm the operation Press End to go back to the previous menu 4 3c Setting temperature levels To modify the 3 temperature levels press on the icon Q LEVELS fig 12 The display will show the menu as in fig 14 Select one of the three levels and modify it by press ing A or V After confirmation you will return to the menu with the list of the days of the week ATTENTION In MANUAL or AUTOMATIC operation if the relay rel ative to the zone is act
17. 9 35 Bedroom Bathrooms Os Kitchen Living room Fig 18 AA Frida Crom HA Bathroom Kitchen Living room Fig 19 bpt LIGHTS 7 CONTROL OF LIGHTS From the main menu fig 17 press the icon LIGHTS The display will show the first four lighting points up to 100 controlled by the Hoasis Plus system fig 18 To view other installed lighting points press on the arrows on the lower part of the display The icons show the status of lighting points By pressing on them you can turn the connected lights on or off Light Off Light On If the list includes lights controlled by a Dimmer module you can also change the intensity of light by pressing the appropriate icons kal 5 Variation of lighting intensity You can change the luminosity of the light to 5 dif ferent intensity levels You can also turn the light on or off by pressing on the status icon The level of lighting intensity that you set is memo rized for the next time you turn on the lights To go back to the initial screen press the key Home or the key OK OPENINGS 8 CONTROL OF OPENINGS From the main menu fig 17 press the icon OPEN INGS The display will show the first four available opening closing devices up to 40 controlled by the Hoasis Plus system fig 19 To view other installed opening closing devices press on the arrows at the bottom of the display 22 OH T
18. ATE icon and then on the icon A to access the window shown in fig 4 where you can select the system operating mode COOLING 4 SUMMER HEATING amp WINTER fig 4 All climate control zones can be deactivated by pressing on the icon gt OFF ATTENTION After selecting one of the two system operating modes all of the climate control zones are deactivated gt on OH T OFF on OH Z OH T 01 interface plus User s manual Friday aa C Bedroom Bathrooms C Kitchen C Living room Fig 5 20 2 c 22 0 c 20 5 c 20 5 c Friday Bedroom GA HOME aa Friday EM Bedroom LI 1 90 Le A 09 30 hi DAYS 4 TEMPERATURE SETTING From the main menu fig 2 press on the icon The display will show the list of the first four zones maximum 20 in which the climate control system is installed along with the corresponding temperature and operating mode fig 5 To view other zones which may be visible press on the arrows located in the lower part of the display fig 5 The 20 zones available may contain up to 19 OH Z modules and not more than 3 OH T modules Ifone or more zones is highlighted it means that the corresponding relay is active and the system is in operation NOTE From this menu it is possible by pressing on the name of the involved zone to access the menu where the corresponding settings can be modified fig 6 4 1 MANUAL OPERATION
19. Press on the box for one of the air conditioning zones The menu will appear as in fig 6 Press on the MANUAL icon to activate MANUAL operation Press A or v to modify the set temperature for the zone The unit is provided with a default manual temper ature level of 20 C 4 2 TIMED MANUAL OPERATION HOLIDAY PROGRAMME The Holiday programme lets you activate tempo rary programming of the zone temperature which will be in effect only for a certain number of days or hours When you press this icon you will access the window shown in fig 7 From here you can choose how long the zone is to remain at the set temperature When you press OK the Holiday programme will be in effect for the amount of time established After that automatic operation will be restored The unit is provided with a default Holiday tem perature level of 20 C OH T 01 interface plus am Friday HOME 20 0 18 0 16 0 E I Bedroom Friday Bedroom 24 0 c OFF Friday Bedroom 09 35 16 0 c 09 35 09 50 WEDNES DAY GI SUNDAY TI T2 T3 LEVELS Cancel User s manual 4 3 AUTOMATIC OPERATION 4 3a Pre set heating and cooling programmes Press on the icon AUTO fig 8 Operation of the thermostats during the course of the day is shown by a diagram fig 8 fig 9 which shows on the horizontal axis the hours of the day and on the vertical axis 3 preset temperatur
20. RATION Press on the square for the first climate control zone fig 4 The menu will appear as in fig 5 Press on the icon 8 to activate MANUAL operation fig 6 The unit is provided with a default manual tempera ture level of 20 C Press or W to modify the set temperature level 3 2 AUTOMATIC OPERATION 3 2a Pre set heating and cooling programmes Press on the icon s AUTO The operation of the thermostats throughout the day is shown by a diagram fig 7 fig 8 with hours of the day on the horizontal axis and the three pre set temperature levels on the vertical axis which are For heating T1 16 C T2 18 C T3 20 C For cooling T1 24 C T2 26 C T3 28 C The terminal contains the preset temperature levels and programmes valid for all days of the week and which can be modified as you wish 3 2b Modification of programs When the AUTO icon has been activated fig ures 7 8 the profile of the set temperature for the current day of the week is shown The trend of the profile is obtained from the repre sentation of the highest value for each hour of the day The flashing cursor indicates the time corre sponding to the clock time It is possible to display the trend of the enlarged pro file 6 hours by pressing on the same profile After 5 seconds the 24 hour profile will be shown again If you want to modify the profile press on the icon 4 CHANGE The display will show a list of the days of t
21. September ENTER EXIT NIGHT Fig 21 User s manual grammed remote controls as it only has a stop func tion during opening and closing movements When controlling the NH DIM modules the forcing function OFF only has an OFF function as regards to the active dimmer control and does not disable local controls or other programmed remote controls Press on the icon AUTO to restore the programmed functions If the selected zone is also controlled by one or more timers and is in Automatic mode e g Bathrooms in fig 16 the display will show the menu as in fig 18 10 TIMER PROGRAMMING AND MODIFICATION Press on the icon M DAY to choose the days of the week in which you want the timer to be active fig 19 Press on OK to return to the previous menu Press on the icon mm The list of timer activations will appear fig 20 By selecting one of these up to 4 activations per day it is possible to set the interval of operation of he timer Upon completion of this operation press OK to go back to the previous menu fig f more than one timer has been installed in the zone press on to select the next one Repeat the operations of the previous timer for pro gramming The relay will then be activated for each pro grammed activation of the timers Press on End the zone menu is displayed fig 16 and then press on the icon to return to the ini tial menu fig 2 11 ACTIVATION OF SCENARIOS If
22. UL INFORMATION Cleaning of the screen and unit cabinet should only be done with a soft cloth Before doing this lock the screen by pressing button A fig 27 If the password printed on the label located inside the terminal is not legible you can view it on the display by doing the following Open the unit by using a screwdriver in the slot fig 28 to view the Password remove the power supply connector from the printed circuit fig 29 hold down button A while replacing the connector close the unit If a horizontal line appears on the display remove the power supply connector from the printed circuit fig 29 and reinsert it after at least 30 seconds have elapsed 38 OH T 01 Basic interface bet Installer s Manual 12 TECHNICAL FEATURES Unit for civil use Back lit LCD touch screen display Power supply from bus line BUS line specifications The cable provided must be a twisted pair shield less and non polarized It is important to keep in mind that if you use the twisted pair telephone line compliant with CEI 46 5 which is not insulated for the voltages being used it must be placed in special ducts that is not used for wiring at a voltage of 230 V AC Anti freeze temperature 8 C Field of adjustment from 2 to 35 C Room temperature measuring interval 30 seconds Thermal differential adjustable from 0 1 C to 0 9 SG Reading resolution 01 C Displayed
23. con Ze The request for configuration of the home automa tion system is shown fig 19 Continue by installing if present modules OH R without jumpers SW1 3 inserted OH RI OH 6l OH RP and any other expansion modules by press ing on the service push buttons located on the devices to be installed if not previously installed Installation is confirmed by the flashing of the LED located on the device and by the increase of the number of relays and inputs detected on the termi nal depending on the type of module This operation can also be carried out later for the addition of new modules NOTE When the system is started for the first time no password insertion is required When you activate the password button fig 19 subsequent accesses to the system will be permitted only by inserting the password fig 12 The password is composed of the first 4 numbers and or letters of the ID code of the ter minal printed on the label on the printed circuit If it should be necessary to delete all operations on the home automation part carried out so far press on RESET and confirm the choice WARNING The RESET operation deletes all configurations con cerning only the home automation part and there fore requires that all system configuration operations be repeated Press NO if you want to exit installation Press YES to continue in this case the menu Match name to relay will appear fig 21 34 OH T 01 Basic in
24. e levels which are For heating T1 16 C T2 18 C T3 20 C For cooling T1 24 C T2 26 C T3 28 C The terminal contains the preset temperature levels and programmes valid for all days of the week and which can be modified as you wish 4 3b Programme modification 19 When the AUTO icon has been activated figures 8 9 the profile of the set temperature for the current day of the week is shown The trend of the profile is obtained from the represen tation of the highest value for each hour of the day The cursor flashes at the current hour When you press on the profile an enlarged portion of six hours of the profile will be displayed After 5 seconds the display will again show the 24 hour profile If you want to modify the profile press on the icon CHANGE fig 9 The display will show a list of the days of the week fig 10 When you select the day for which you wish to make the change the programmed daily profile in the 24 hours fig 11 OH T 01 interface plus User s manual 09 30 16 0 c Monday Bedroom aa HOME 16 0 18 0 200 CoC Fig 11 Friday 09 50 Bedroom WEDNES THURS vo uso DAY DAY SATUR LE T2 DAY SUNDAY T3 LEVELS Fig 12 Cancel Friday 09 40 Copy from pen Bedroom HOME In S li Living room V Fig 13 bpt If you press any of the push buttons underneath a time period of
25. el operation 5 Push button to lock controls on display 6 On line help 7 Confirm operation WARNINGS For proper use of the unit use the special pen provided OH T 01 Basic interface TEMP DOMO Tue 30 September Fig 2 sn Friday HOME 202 c 22 0 iin 205 8 Bedroom 4 Bathrooms Kitchen Living room 20 5 c Fig 4 User s manual 2 SETTING THE CLOCK From the main menu fig 2 press on the strip where the time and temperature are displayed The display will show the menu Set time and date fig 3 Select the box where you want to update the data and press on or W to modify it Press OK to confirm the operation Press on the icon ACTIVATE DAYLIGHT SAVINGS TIME to activate or deactivate daylight savings time NOTE If activated changeover to daylight savings time takes place automatically This operation will not take place if there is no power supply 3 TEMPERATURE SETTING From the main menu fig 2 press on the icon TI The display will show the list of the possible first four zones Maximum 8 in which the climate control sys tem is installed along with the corresponding tem perature and operating mode fig 4 of ET Automatic mode M Manual mode OH T 01 Basic interface User s manual Friday Bedroom 20 2 Friday Bedroom Friday Bedroom tl 09 30 C 09 30 09 35 16 0 c 3 1 MANUAL OPE
26. en you activate the password button fig 11 subsequent accesses to the system will be permitted only by inserting the password fig 12 The password is composed of the first 4 numbers and or letters of the ID code of the ter minal printed on the label on the printed circuit If it should be necessary to delete all operations on the thermal part carried out so far press on RESET and confirm the choice Press NO if you want to exit programming Press YES if you want to continue with program ming 31 OH T 01 Basic interface Installer s Manual Link Therm to Relays Thermostat Relay P 01 Vv 01 c Bedroom Fig 13 RELAY 01 Bedroom se 0 4 Electric Convect gt i EC DIFFER Fig 14 Cancel Differ Threshold RELAY 01 02 A RE 15 Fig bpt The display shows the installed thermostats ther mostat 01 for the OH T terminal the relays to be assigned to the control device of the air conditioning device e g circulation pump solenoid valve motor valve and the name of the zones where the thermo stats are installed fig 13 Match the relays to the thermostats by selecting the preset zone names If you want to modify them press on the name of the zone on the points in this case a personalized name is added and the menu will appear to make it possible to do so NOTE The relays used in the home automation part if previ
27. field of reading from 0 C to 35 C Precision lt 0 5 C Pollution situation normal aximum temperature of control head 40 C Protection rating IP30 Operating temperature from 0 C to 35 C Dimensions 116x95x27 mm 39 bpt OH T 01 interface plus Installer s Manual OH T 01 interface plus Installer s Manual bet 1 WARNINGS FOR THE INSTALLER Read the warnings contained herein with care as A C they furnish important instructions regarding safe use installation and maintenance After removing the packaging check the condition of the unit The system must be installed in compliance with current safety standards The manufacturer declines all liability for any dam age as a result of improper incorrect or unreason able use Should the unit be in need of repair contact only a technical support centre authorized by the manu facturer Failure to comply with the above instructions may compromise the unit s safety Fig 1 2 LOCATION OF TERMINAL Install the unit on an internal wall fig 1 in a position which is suitable for correct measurement of the room temperature avoiding installation in niches behind doors or curtains or near heat sources fig 2 3 INSTALLATION OF THE TERMINAL Open the unit by using a screwdriver in the slot
28. functions have been matched to the three scenar ios during installation pressing on one of these icons in the main menu ENTER EXIT NIGHT ENTER EXIT NIGHT fig 21 This section of the manual is for users who have upgraded the Hoasis system from the Base version to the Plus version with the PC HOME programme on the OH T 01 OH T 01 interface plus User s manual OH T 01 interface plus User s manual PROGRAMMING AND CONTROL TERMINAL OH T 01 INTERFACE PLUS The unit allows you to control and activate the main building services in a HOASIS PLUS home automa tion control system The HOASIS PLUS home automation control system is composed of two main units the OH T 01 control terminal and the OH A 01 power supply unit The system manages up to 255 relays and 255 contact inputs 19 of which can be heat controlled OH Z 02 The terminal makes it possible to program the temperature and to man age lights irrigation systems automation devices etc In thermal adjustment mode the unit combines vari ous functions summer winter anti freeze pre set programmes date and time display In home automation operation mode it allows the control of 16 0 c Bedroom bpt relays with timers scenarios or activations com manded by the user The touch screen technology makes it possible to set all parameters and program ming just by touching the icons on the display C
29. he week fig 9 OH T 01 Basic interface Friday Bedroom Friday Bedroom 09 35 24 0 c 09 40 WEDNES THURS MONDAY TUESDAY DAY DAY FRIDAY SATUR GN Fig 9 Cancel Monday 09 30 Bedroom 20 0 n LL 18 0 Bi 16 0 ne 16 0 c flea L Fig 10 Cancel User s manual Select the day in which you want to make the mod ification the programmed daily profile for 24 hours Pressing on any of those underneath will display e g during the heating program a range of 6 hours fig 10 To modify the profile scroll the flashing cursor by pressing on lt or until the established time is reached shown on the display at upper right Press on one of the three squares for the tempera ture level to set the desired value NOTE Programming is carried out in intervals of 15 minutes Using only lt 4 or BR after de selecting any levels which may have been selected you can scroll through a profile to check it without modifying it After confirming the modifications you have made you will go back to the menu with the list of the days of the week fig 9 OH T 01 Basic interface User s manual 09 40 GA Friday 5 Copy from Bedrooms A In OI D E Fig 11 Frida Bedroom Set levels AS 09 40 HOME 16 0 18 0 20 0 v K Fig 12 bpt f you want to copy a set temperature profile press on COPY fig
30. ive on the left hand side of the menu figures 6 8 the ON symbol appears When the relay is not active the symbol is absent 20 GA HOME OH T 01 interface plus Friday 09 45 Bedroom Set levels A fsolfted z00 Y du HOME Cancel Friday 20 2 c Bathrooms 22 0 c ET Kitchen 20 5 c Living room 205 ff Fig 15 du HOME Friday 09 35 Bedroom 16 0 c 20 0 an LL 18 0 CI SERRE LI gt I 6 OFF User s manual 5 LOCKING COMMANDS FOR ZONE TEMPERATURE CONTROL From the main menu fig 2 press on the icon E The display will show the list of the first four zones maximum 20 in which the climate control system is installed along with the corresponding tempera ture and operating mode fig 15 To view other zones which may be visible press on the arrows located in the lower part of the display Select the desired zone and press on icon BLOCK fig 16 to deactivate the commands which can be given from the connected OH Z control module 6 ANTI FREEZE In General Settings if you have selected the Win ter key ifthe temperature drops below 8 C the ter minal will automatically activate the anti freeze func tion This occurs even if the zone is off 21 OH T 01 interface plus User s manual imate Openings Scenarios Timers 12 08 202 Fri 12 May SCENE SCENE SCENE Fig 17 GA Friday HOME 0
31. ive parts and restoring the equipments conformity BPT shall bear the cost of parts replaced Parts replaced shall remain the property of BPT f the Customer requests work to check or alter the equipment with respect to the original design that is not necessary for the repair or replacement of defec ive parts or for restoring the equipment s conformi y said work shall be charged at the rates in force 5 Warranty exclusions This conventional warranty is not applicable when he nonconformity is due to the following causes a natural disasters lightning flooding fire earth quake etc b tampering or negligent or improper use or any use that is contrary to the contents of the technical lit erature supplied with the equipment c supply voltage rushes in excess of 6 and 10 or other power supply faults d prolonged disuse of the unit after installation e incorrect or negligent installation or installation that is contrary to the technical literature supplied with the equipment 6 Terms for the warranty s application Any Customer intending to acquire the right to war ranty of conformity must duly fill out this certificate and for its validity to be recognized have it stamped by the Installer authorized Dealer or in the event testing is carried out by the authorized Technical Support Centre by the personnel of said Centre Any Customer intending to exercise the right to war ranty is required to present
32. ll equipment with the excep tion of parts subject to normal wear and tear such as knobs light bulbs parts and components in glass and plastic picture tubes video recorder heads The warranty applies only to the final Customer who must be resident in Italy and must have had the equipment installed by a qualified Installer or have purchased it from an authorized Dealer 2 Parties to the warranty Service under the conventional warranty shall be carried out only by competent personnel belonging to Technical Support Centres authorized by BPT 3 Period of validity of the warranty The conventional warranty shall cover the equip ment for thirty six months from the date of the equipment s installation For CCTV equipment the conventional warranty shall cover the equipment in question for twenty four months from the date of the equipment s instal lation Repairs carried out during the warranty period shall not cause the warranty to be broken off and resumed i e its original duration shall not be extend ed and whatever the case it shall expire thirty six months or twenty four months in the case of CCTV equipment after the date of installation 4 Service under warranty BPT answers the Customer s service requests through the competent personnel of authorized Technical Support Centres preferably aided by the bpt equipment s Installer Service under the convention al warranty includes repair or replacement of defec
33. llowed only if the rel ative relay is not active If it is the Modify and End keys are deactivated the status is indicated by the message Modify written in negative The End key fig 23 in the last function displayed takes you out of the configuration menu leaving the last function matched during the configuration phase unchanged Therefore to correctly complete the zone modification it is necessary to confirm all settings with OK before moving on to the next zone and then press on End 36 OH T 01 Basic interface Installer s Manual id Proceed as per the instructions in chapters 8 and 9 fa Fri ay completing the modifications in the menus in fig HOME ures 22 and 23 L Input 10 1 CANCELLATION OF HOME AUTOMATION Garden CONTROL ZONES To cancel a single home automation zone select Blind up from the menu in fig 26 the relay to be eliminated Blind down and then insert B dots in place of the name of the zone Press on B relay selection to confirm the operation and move on to the next zone Fig 24 Password The system detects 04 inputs and 04 relays Continue Fig 25 Relay 01 D Kg C L Input gt m o ee Fig 26 37 OH T 01 Basic interface Installer s Manual HOASIS CE 09 35 da Bedroom 16 0 c 20 0 EE u Fig 27 Fig 28 Fig 29 11 USEF
34. nato Pianoterra 9 A Pianoterra _ Luce 1 bi Dispositivo non ra Modifica Annulla VY ok programmato a Pianoterra Luce 2 xl OFFLINE Impianto Bagni PrimoPiano PrimoPiano __ Luce 2 PROGETTO 23 05 2006 16 05 03 Fig 7 During download the OH T 01 terminals will show L the screen in fig 8 Upon completion it will be possible to view the new Plus interface on the terminals OH T 01 NOTE The download procedure on OH T 01 takes a few minutes During this time it is not advisable to perform any other action on the network closing of input contacts or control of relays Also during this phase in some cases you may hear a whistle from the OH T 01 It will stop when the download is complete C Fig 8 45 OH T 01 interface plus Installer s Manual HOASIS A MISE 09 35 Bedroom 16 0 c pis CHANGE Fig 9 Fig 10 Fig 11 5 USEFUL INFORMATION Cleaning of the screen and unit cabinet should only be done with a soft cloth Before doing this lock the screen by pressing but ton A fig 9 If the display shows a horizontal line open the unit by inserting a screwdriver into the slot fig 10 remove the power supply connector from the print ed circuit fig 11 and re insert it after waiting at least 30 seconds 6 TECHNICAL CHARACTERISTICS
35. o 8 inputs can be used for each single relay The selected inputs are shown in bold face in their sub list and with the symbol in fig 2 2 When programming of zone inputs is complete press on End and the menu will be shown as in fig 23 9 FUNCTION OF INPUTS In the menu fig 23 you must select with which function the concerned input controls the chosen zone relay The functions can be activated by the opening or closing of a contact on the programmed input by selecting Cnt closed or Cnt open fig 23 or by timer events timers 1 16 scenarios ENTER EXIT NIGHT on the module OH T01 or by the input located on the thermostats OH Z 02 35 OH T 01 Basic interface Installer s Manual Types of functions associated with command input Press on to display the subsequent functions a Step The relay is alternately activated and deactivated by successive actions on the control inputs b ON The relay if inactive is activated by the control inputs c OFF The relay if active is deactivated by the control inputs d Direct The activation of the relay follows the status of the control input e g switch e Impulse Relay activation occurs for a programmed time duration from 00 min 00 s to 59 min 59 s It is possible to delay the activation of the relay delay from 00 min 00 s to 59 min 59 s f Activation The activation of the relay as a result of the various conditions of the other control in
36. ommunication between the various units in the sys tem takes place by means of a bus realized on a sin gle twisted pair DESCRIPTION 1 Pen for touch screen 2 Go back to previous menu 3 Display touch screen 4 Cancel operation 5 Button to lock controls on display and turning on of back lighting 6 Confirm operation WARNINGS For proper use of the unit use the special pen provided OH T 01 interface plus 12 08 20 2 c Fri 12 May SCENE SCENE SCENE Fig 2 Friday General settings WINTER OFF User s manual The Hoasis Plus system makes it possible to control thermal zones lights openings scenarios and timers After upgrading the system from the Basic version to the Plus version with the PC HOME programme on the OH T 01 terminal the screen display will be shown as in Fig 2 2 SETTING THE CLOCK From the main menu fig 2 press on the strip where the time and temperature are displayed The display will show the menu Set time and date fig 3 Select the box where you want to update the data and press on A or F to modify it Press OK to confirm the operation Press on the icon ACTIVATE DAYLIGHT SAVINGS TIME to activate or deactivate daylight savings time NOTE If activated changeover to daylight savings time takes place automatically This operation will not take place if there is no power supply CLIMATE 3 GENERAL SETTINGS From the main menu fig 2 press on the CLIM
37. ously selected will not be shown during this program Repeat the same procedure for the other previously numbered thermal adjustment zones Press on End to conclude this operation You will now enter the menu for the selection of the climate control system installed in the various zones of the building and connected to each relay fig 14 By pressing on the icon you can modify the pre set values of the thermal differential based on the ype of climate control system used for that zone fig Press OK if you want to confirm the operation or wait 5 seconds Press B fig 14 to perform the same operations for he next relay Press OK to conclude programming of he thermal zones Cooling Heating with fan unit heaters 9 Electrical heating Heating with radiators Floor heating Temperature differential 32 OH T 01 Basic interface Fig 16 Bedroom 20 2 c Bathrooms 22 0 c Kitchen 20 5 c Living room 20 5 c Fig 17 Installer s Manual 6 GENERAL SETTINGS OF THE AIR CONDITIONING SYSTEM From the main menu fig 6 press on the icon Ty hen press amp in the next menu the General set ings menu will appear fig 16 from which you can choose the system operating mode HEATING con rol of relays associated to ts M 4 COOLING control of the relays associated to 3 2 All climate control zones can be deactivated by
38. ower supplier OH A to the local network After 20 seconds the terminal display will show the main menu fig 6 28 OH T 01 Basic interface bet Installer s Manual WARNING For correct programming of the terminal proceed as follows Fill out the tables included with the power supplier OH A Set the clock Install and program the climate control zones Install the home automation control zones 29 OH T 01 Basic interface Installer s Manual T TEMP Tue 30 September Fig 6 Fig 9 Fig 7 4 SETTING THE CLOCK From the main menu fig 6 press on the band where the time and temperature are displayed The display will show the menu Set time and date fig 7 Select the box where you want to update the data and press on or W to modify it Press OKto con irm the operation Press on the icon ACTIVATE DAYLIGHT SAVINGS TIME to activate or deactivate daylight savings time NOTE If activated changeover to daylight savings time takes place automatically This operation will not take place if there is no power supply 5 CONFIGURATION AND PROGRAMMING OF AIR CONDITIONING ZONES From the main menu fig 28 press on the icon Ty The display will show the list of zones installed in the climate control system temporarily empty fig 8 since the names of the installed zones will be displayed after ca
39. puts is activated or de activated by the control inputs to which this function is matched Press OK to continue programming the subsequent inputs and or events for zone control until you get to the menu in fig 22 concerning the next zone Press OK on the last setting of the last configured zone to go back to the starting menu fig 10 MODIFICATION OF HOME AUTOMATION CONTROL ZONES If the complete configuration of the home automa tion control zones has been performed and you want modify the settings for a single relay from the main menu fig 6 press on the icon Q The display will show the list of the installed home automation zones fig 24 Then press on the icon 44 The screen display will be shown as in fig 25 In this menu it is possible to acti vate or deactivate the password by pressing on Password Activation is indicated by a message written in neg ative If it should be necessary to delete all operations on the home automation part carried out so far press on RESET and confirm the choice WARNING The RESET operation deletes all configurations con cerning the home automation part and therefore requires that all system configuration operations be repeated Press NO if you want to exit installation Pres YES to continue in this case the menu Match name to relay will appear fig 26 Press on B to choose the relay zone to be modified and then press on Modify WARNING The modification operation is a
40. rrying out the programming procedure Press on the icon amp the General settings menu will appear fig 9 then press on The Online Guide window will automatically appear with instructions on how to install new heat ing zones fig 10 30 OH T 01 Basic interface WARNING To install new heating zones press the button on the other thermo Fig 10 Password The system detects 01 therm and 00 relays Continue V RESET l Installer s Manual Press OK the display will show the total number of thermostats and relays detected fig NOTE The OH T terminal is also counted in the num ber of thermostats Press the key included on each OH Z zone tem perature control module if connected to allow recognition and assignment in sequence of the rela tive zone number Continue by installing if present modules OH R without jumper SW1 3 inserted OH RI OH 6l OH RP and any other expansion modules by press ing on the service push buttons included on the devices to be installed if not previously installed Installation is confirmed by the flashing of the LED on the recognized device and by the increase of the number of relays and thermostats detected on the terminal depending on the module fig 11 This operation can also be carried out later for the addition of new modules NOTE When the system is started for the first time no password insertion is required Wh
41. terface Match name to relay Relay A D gt Ea Fig 21 Inputs used for relay Bathrooms Inputs C Timers Scenarios J Inputs Therm e o E Fig 22 Input 01 Bathrooms active with Cnt closed J and function Step Installer s Manual Press on B to choose the number of the relay and then on lt or gt to match the name of the zone from those which are pre memorized in the library If you want to modify them press on the name of the zone on the points in this case a personalized name is added and the menu will appear to make it pos sible to do so Press End when the operation is com plete to move on to the Inputs used for relay menu ATTENTION The keys End and Modify are inactive if the dis played relay is active status is indicated by the mes sage Modify written in negative For more about the functions of the Modify key see chapter 10 MODIFICATION OF THE HOME AUTOMATION ZONES OF CONTROL NOTE The relays used in the thermal part will not be shown during this program 8 CHOICE OF INPUTS In the menu fig 22 the inputs are defined that will guide the relays e g Bathrooms There are 4 possibilities Inputs contact input of modules OH A OH R etc Timers User program mable timer Scenarios ENTER EXIT NIGHT or Thermostat Inputs contact input for zone modules OH 2 Up t
42. ts lights openings and timers of the single OH T 01 devices insert the zones you intend to view and control from the single ter minals following the online help instructions If the system includes more than one OH T 01 termi nal you will need to choose which of them will per form the Master function of the thermal zones The Master terminal will show all heating zones included in the system Also when configuring the Master terminal it will be necessary to establish the setting for Advance function and Delta 8 C for the heating zones see page 33 Once the structure has been created download the system by clicking on Diagnostic programme fol lowed by System Programme OH T 01 interface plus bet Installer s Manual Conness Rete Per la guida premere il tasto F1 FTT 10 Impianto Zona Camera E Cameretta c Cameretta __ Pulsante 1 Spazio Componenti rete IN Cameretta __ Pulsante 2 Inc Cameretta __ Pulsante 3 Inc Moduli z Modulo OH RI 1 e Modulo OH RI 2 Camere R Camere Luce 1 a Moduli 0H RP 0H 2RP QE Modulo 0H R CI Configurazione Sor i Cy Camere __ Luce 2 NC i Cy Camere _ Luce 3 Dispositivo non eee E Camera Id Bagni Codice identificazione l non asseg