1. User Manual Infra Cool Rack Airflow Control AUSTIN F 33 9A F 33 9B 33U Door Mount Basic Fan Panel j 11 pad y P Lo AME Ed am TEF E E FC ce v REACH www austin hughes com UM IC Basic 33U Q415V4 Legal Information First English printing October 2002 Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Please read all of these instructions carefully before you use the device Save this manual for future reference B Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth B Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit B When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing dam age to other equipment or injury to persons nearby B When the equipment is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to keep it from overheating B Arrange the equipments power cord in such a way that others won t trip or fall over it
2. 9 Door mount Fan Panel is typically installed on the outside of a rack s rear perforated door to improve extraction of heat from high density rack The unit can be attached to most 42U or taller racks If aisle is relatively narrow for exterior mounting the unit may be installed on the inside of the perforated door For details please refer to the model table below Front Door Cool Air In Model Installation Rear door outside F 33 9A P Front door inside Front door outside F 33 9B a Rear door inside Unpacking Airflow Extract airflow Intake airflow Intake airflow Extract airflow Rear Door Hot Air Out Purpose Exhaust air out from rack Cool air in from aisle Cool air in from aisle Exhaust air out from rack The equipment comes with the standard parts shown on the package contents Check and make sure they are included and in good condition If anything is missing or damage contact the supplier immediately Package Content 33U door mount fan panel x 1 pc 6 ft power cord x 1 pc User Manual x 1 pc Mounting screw x 6 pcs attached with the unit Air blocking material x 1 pc Optional mounting kit Hanging bracket kit Part no F HBK Hanging bracket x 2 pcs M4 6mm screw with nut x 4 sets M4 10mm screw x 2 pcs UM IC Basic 33U Q415V4 For installation please refer to p 4 P 1 www austin hughes com Caution Power off the fans if the door is to be opened for
3. maintenence or service of items within the rack The fans have finger guards but care must be excerised when working around spinning fans Keep hair fingers and other small objects away from the spinning blades UM IC Basic 33U Q415V4 P 2 www austin hughes com Installation steps The weight of the unit is less than 5kg so in most cases holes in perforated rack doors can be used to mount the unit Lift the unit to the desired position 2 Place attached 6 screws then through the door and tighten them To eliminate bypass air to maximize heat removal from the rack cut the air blocking material to the size necessary with cutter or scissors then apply the material to the inside surface of the door with screws or adhesive backing Ensure all open perforations are covered by the material O Connect the power cord to the PDU of the rack through the cable entry hole on the rear top of the rack 9 If no cable entry on the top the unit may be installed on the inside but the model need to be changed Please refer to P 1 Use cable clip to hold the power cord if necessary Mounting screws ON OFF Button Perforated Rack Door UM IC Basic 33U Q415V4 P3 www austin hughes com Hanging bracket installation amp D Assemble amp adjust the hanging bracket with M4 6mm screw amp nut to fit the thickness of the door Install the hanging bracket kit on the rear side of the fan panel with M4 10mm screw Hang the unit on the door
4. B If you are using a power cord that didn t ship with the equipment ensure that it is rated for the voltage and current labeled on the equipment s electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipments ratings label mM Observe all precautions and warnings attached to the equipment B If you dont intend on using the equipment for a long time disconnect it from the power outlet to prevent being dam aged by transient over voltage B Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock B Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invali date its warranty B If any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel What the warranty does not cover B Any product on which the serial number has been defaced modified or removed B Damage deterioration or malfunction resulting from Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product L Repair or attempted repair by anyone not authorized by us Any damage of the product due to shipment L Removal or installation of the product Causes external to the product such a
5. Place attached 4 screws then through the door and tighten them 90070 Follow steps on P3 ON OFF Hanging bracket with Button M4 6mm screw amp nut T Tf l m s _ s sssi M4 10mm screws Mounting Screws Perforated Rack Door UM IC Basic 33U Q415V4 P 4 www austin hughes com Dimensions F 33 9 195 www austin hughes com P 5 UM IC Basic 33U Q415V4 Specifications Fan e Operating 0 to 50 C Degree Storage 5 to 60 C Degree Relative humidity 5 90 non condensing Shock 50G peak acceleration 11ms half sine wave Vibration 58 100Hz 0 98G 11ms cycle Weight w s o Li n1 O Net Gross 4 6 kgs 10 1 Ibs 6 9 kgs 15 2 Ibs Casing Color Mounting 33U door mount Power ME sS zz z2 lll l Auto sensing 100V or 240V AC at 50 or 60Hz via IEC type cord Dimensions O 195 x 38 4 x 1466 mm 7 7 x 1 5 x 57 7 inch 263 x 106 x 1650 mm 10 4 x 4 2 x 65 0 inch Regulatory FCC CE Environmental RoHS2 amp REACH compliant The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2015 Austin Hughes Electronics Ltd All rights reserved
6. UM IC Basic 33U Q415V4 P 6 www austin hughes com
7. s electric power fluctuation or failure Use of supplies or parts not meeting our specifications Normal wear and tear L Any other causes which does not relate to a product defect B Removal installation and set up service charges Regulatory Notices Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures B Re position or relocate the receiving antenna mM increase the separation between the equipment and receiver B Connect the equipment into an outlet on a circuit different from that to which the receiver is connected UM IC Basic 33U Q415V4 www austin hughes com F 33