Home
UNICORN version 2.32 - GE Healthcare Life Sciences
Contents
1. 98 02 04 i Amersham Biosciences 56 3070 43 Edition AA UNICORN V2 32 Upgrade Information i UNICORN V2 x Local Installation 1 Double click on the OS 2 System icon on the desktop then on the DRIVES icon and finally on the DRIVE C icon Double click on the UNICORN folder and then on the LOCAL folder Put the cursor on the FIL folder click the right mouse button and select copy Change the name to UNI_FILES Click on the DRIVE C icon 6 Click on the COPY button UNICORN V2 x Network Installation SR ni Firstly find out where your methods and result files are stored 1 Double click on the OS 2 System icon on the desktop then on the DRIVES icon and finally on the icon where is the drive where your result and method files are stored Double click on the UNICORN folder and then on the LOCAL folder Put the cursor on the FIL folder click the right mouse button and select copy Change the name to UNI_FILES Click on the icon where is the drive where your result and method files are stored Click on the COPY button DAR DUNS Installation The following procedures describe how to upgrade from version 2 x to version 2 32 without changing system configuration for both stand alone computers and those in networks Stand Alone 1 Double click on the OS 2 System icon on the desktop then on the DRIVES icon and finally on the DRIVE C icon 2 Double click on the Drive C icon in the Tree View to see the files un
2. UNICORN version 2 32 Upgrade Information This document describes the new features in UNICORN version 2 32 and how to upgrade from older versions 1 New features This is an upgrade from version 2 30 to 2 32 of UNICORN Version 2 31 was never released The major changes between version 2 30 and 2 32 of UNICORN are General Handling of messages in Documentation Logbook is improved Main Menu Handling of global Audit Trail in network environments is improved System control Dynamic symbols in the process picture are now positioned correctly Horizontal lines in the process picture will not be missing The connection of system modules is improved UPGRADE When upgrading from an older UNICORN version your files will automatically be updated but it is always a good idea to make backups of your result and method files If you have a backup facility like a Tape station or a Magnet Optical drive use that to back up your files Otherwise make a copy of the catalog and save it under a different name as shown in the examples below UNICORN V1 x 1 Double click on the OS 2 System icon on the desktop then on the DRIVES icon and finally on the DRIVE C icon Double click on the MPM folder to open it Put the cursor on the FIL folder click the right mouse button and select copy Change the name to UNI_FILES Click on the DRIVE C icon Click on the COPY button DAN wW PD 56 3070 43 Edition AA 19
3. ant that all computers in a network using the same UNICORN server have the same UNICORN version installed 1 Double click on the OS 2 System icon on the desktop then on the DRIVES icon and finally on the DRIVE C icon 2 Double click on the Drive C icon in the Tree View to see the files under c 3 Put the cursor on the STARTUP CMD icon click the right mouse button and select Settings 4 Click on the General tab change the title to STARTUP OLD put the cursor on the title bar icon and double click 5 Restart by clicking with the right mouse button on the OS 2 desktop and choose Shutdown from the menu When the shutdown procedure is complete turn the power off and on again to restart the computer 6 Logon to your network and map your UNICORN drive to the UNICORN server See Chapter 12 in the User Manual 7 Insert UNICORN disk 1 in drive A 8 Double click on the OS 2 System icon on the desktop then on the DRIVES icon and finally on the DRIVE A icon 9 Double click on the INSTALL icon The installation program will start If this fails open a Command Window and type A INSTALL 10 Make sure that Program and Adviser are checked Do not select any other option Click on OK 11 Answer the other questions that appear UNICORN installation program will suggest the same type of installation as before Normally all you need to do is click OK to these questions 12 The installation will now start Change diskette when
4. der c 3 Put the cursor on the STARTUP CMD icon click the right mouse button and select Delete 4 Restart by clicking with the right mouse button on the OS 2 desktop and choose Shutdown from the menu When the shutdown procedure is complete turn the power off and on again to restart the computer 5 Insert UNICORN disk 1 in drive A 6 Double click on the OS 2 System icon on the desktop then on the DRIVES icon and finally on the DRIVE A icon 7 Double click on the INSTALL icon The installation program will start Note If this fails open a Command Window and type A INSTALL 8 Make sure that Program System and Adviser are checked Do not select any other option Click on OK 9 Answer the other questions that appear Note The UNICORN installation program will suggest the same type of installation as before Normally all you need to do is click OK to these questions 10 The installation will now start Change diskette when prompted to do so 11 A message appears on the screen when the installation is complete Remove the diskette but do not restart the computer yet 56 3070 43 Edition AA UNICORN V2 32 Upgrade Information 2 4 Network Note Note Note 12 Restart by clicking with the right mouse button on the OS 2 desktop and choose Shutdown from the menu When the shutdown procedure is complete turn the power off and on again to restart the computer 13 Installation is complete It is import
5. ld MPM directory to the new UNICORN directory and convert them to the 2 32 format The MPM directory and all files in it will then be deleted If you are upgrading from Version 2 x your files will not be changed or deleted If you have upgraded and and want to use an old result and method file that was not automatically converted to 2 32 format because it was not stored in the old UNICORN directory use the Copy from external facility in UNICORN See Section 3 2 8 in the User Manual for more information If you have used a backup unit and need to use an old result or method file Restore the fils to a new directory for example c uni_files Then use the Copy from external facility in UNICORN See Section 3 2 8 in the User Manual for more information For BioPilot System FPLC System and BioProcess System Old methods with None selected as Column in the Base instruction now have this instruction marked in red Delete it and replace with a new Base instruction with Any selected as Column 56 3070 43 Edition AA UNICORN V2 32 Upgrade Information 4 4
6. prompted to do so 13 A message appears on the screen when the installation is complete Remove the diskette but do not restart the computer yet 14 Double click on the OS 2 System icon on the desktop then on the DRIVES icon and finally on the DRIVE C icon 15 Double click on the Drive C icon in the Tree View to see the files under c 16 Put the cursor on the STARTUP OLD icon click the right mouse button and select Settings 17 Click on the General tab change the title to STARTUP CMD put the cursor on the title bar icon and double click 56 3070 43 Edition AA UNICORN V2 32 Upgrade Information 3 4 18 Restart by clicking with the right mouse button on the OS 2 desktop and choose Shutdown from the menu When the shutdown procedure is complete turn the power off and on again to restart the computer 19 Installation is complete Installation of UNICORN Analysis Module Extra module order separately 1 Insert the UNICORN Analysis Module diskette in drive A 2 Double click on the OS 2 System icon on the desktop then on the DRIVES icon and finally on the DRIVE A icon Note If this fails open a Command Window and type A INSTALL 3 The installation will now start 4 A message appears on the screen when the installation is complete Remove the diskette 5 Installation is complete If your previous version was 1 x the installation program will copy all result and method files that were stored under your o
Download Pdf Manuals
Related Search
Related Contents
Samsung AW241QB User Manual Samsung SP-50L6HV Uživatelská přiručka mojo3D - Virtual Wrench Hauck Player NTE INEN-ISO 6750 - Servicio Ecuatoriano de Normalización Electrolux EL8602A vacuum cleaner The Automated Metadata-driven Table Generation manual port phone rev.C.cdr ultraflow Manual Genie 11.cdr - Ultra Copyright © All rights reserved.