1.    Product User Manual         Model GA610x Series  Downstream Plasma Applicator                Document   930027  Rev  2          II   II  Lngd                    4       A       GERLING APPLIED  ENGINEERING  INC     P O  Box 580816 Modesto  CA 95358    www 2450mhz com    Product User Manual Page 2       Model GA610x Series Downstream Plasma Applicator       REVISION HISTORY                            REV  DESCRIPTION DATE APPROVAL  2 ADDED OPTIONAL SPACERS 14JAN04 JFG  WARRANTY       Products manufactured and sold by Gerling Applied Engineering  Inc      GAE     are  warranted to be free of defects in materials and workmanship under normal use and  service for a period of twelve  12  months from the date of original shipment  GAE   s  obligation under this warranty is limited to repairing or replacing  at GAE   s option  all  non consumable component parts  Consumable parts are specifically excluded from  this warranty and may include  but are not be limited to  magnetrons  fuses  lamps   seals  o rings  v belts  and fluids  All warranty repairs are to be done at GAE s facility or  as otherwise authorized by GAE  All shipping charges for warranty repair or  replacement are the purchaser   s responsibility unless otherwise agreed to by GAE     This warranty supercedes all other warranties  expressed or implied  No warranty is  given covering the product for any particular purpose other than as covered by the  applicable product specifications  GAE assumes no liability in any
2.  2     Typical GA6101 vacuum flange connections     VACUUM FLANGE  HARDWARE    GAS FEED ADAPTER   SUPPLIED BY CUSTOMER        2 3 4  CONFLAT  2 PLCS VACUUM FLANGE   2 PLCS    SS    GA6102 DOWNSTREAM  PLASMA APPLICATOR       CHAMBER LID ADAPTER   SUPPLIED BY CUSTOMER     Figure 3     Typical GA6102 vacuum flange connections           2003 2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 9  Model GA610x Series Downstream Plasma Applicator       Water Fitting Connections    Connections for water cooling are made to two 77  Swagelok     compression fittings  The source of water can be connected to   either fitting  The fitting must be torqued according to Swagelok     specifications to ensure a leak free connection  Care should be   taken to prevent debris from falling into the fitting holes while  A disconnected     CAUTION  Use wrench tools on both sides of the fitting  connection to immobilize the mating fitting while tightening the  fitting nut  Failure to secure the mating fitting while tightening can  cause damage to the copper water tubing protruding from the  cooling block           2003 2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 10       Model GA610x Series Downstream Plasma Applicator    OPERATION       Basic Operation    Once installed  operation of the GA610x series Downstream  Plasma Applicator consists of the following basic steps     1  Establish a vacuum within the plasma tube and start the flow  of
3.  against the water cooling blocks  Equal lengths of  plasma tube should be protruding past the o rings     6  Carefully position the VACUUM FLANGE ADAPTERS over  the ends of the PLASMA TUBE           2003 2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 13  Model GA610x Series Downstream Plasma Applicator       7  Using the hardware previously removed  secure the  adapters in place by hand tightening the screws on both  ends first  Then tighten the screws evenly at both ends by  alternating diametrically until the adapters are secured           SOCKET HEAD SCREWS    j I AND LOCKWASHERS    VACUUM FLANGE ADAPTE   2 PLCS     O RING SEAL  2 PLCS   PLASMA TUBE                            A                                     GA610x DOWNSTREAM  PLASMA APPLICATOR       Figure 4     Exploded view for removal and replacement of the  plasma tube and o rings     Replacement Parts  Description GAE Part Number  Plasma Tube  Quartz 911142 XX XX  XX XX   Nominal length in inches  O Ring  Parofluor 420103 214          2003 2004 Gerling Applied Engineering  Inc  Modesto  CA    
4.  event for incidental or  consequential damages  financial losses  penalties or other losses incurred in  conjunction with the use of GAE products     DOCUMENT CONVENTIONS       NOTE  Means the reader should take note  Notes contain  helpful information  suggestions  or references to other sections   chapters  or documents     CAUTION  Means the reader should be careful  You are doing  something that might result in equipment damage or loss of data     WARNING  Means danger  A situation exists that could cause  bodily injury or death  All personnel must be aware of the hazards  involved with high voltage electrical circuitry and high power  microwave devices     Pb       O 2003 2004 Gerling Applied Engineering  Inc  Modesto  CA       Product User Manual Page 3       Model GA610x Series Downstream Plasma Applicator       WARNING    All waveguide applicators manufactured by GAE  Inc  are intended for use with other  equipment capable of producing a microwave field that is potentially hazardous to  operating personnel  They must never be connected or operated in a manner that  allows a field in excess of 10 milliwatts per square centimeter to be generated in an  area accessible to operating personnel  Contact GAE  Inc  for technical support prior to  installation and or operation of these units if there is any question or concern about  microwave leakage     All waveguide flange and electrical cable connections throughout the system must be  secure prior to operation  Never oper
5.  manual tuner adjustments and greatly  enhance overall system performance     When using manually adjusted impedance matching devices   however  a compromise in optimization between the pre  and post   ignition states is often necessary  Ideally  such a compromise  allows ignition and steady state operation of the plasma without       O 2003 2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 11       Model GA610x Series Downstream Plasma Applicator    adjusting the matching devices but results in often reduced overall  efficiency     The following procedure may be helpful in finding the optimal  adjustment settings when using a manual tuner and SSC     1  Adjust the SSC plunger to approximately 4 3    from the  waveguide flange  This positions the shorting plane at 3 4      guide wavelength from the center of the plasma tube  The  maximum electric field will then be positioned at the plasma  tube     2  Adjust the tuner stubs to be fully retracted from the inside of  the waveguide  see tuner User Manual for an outline of a  standard tuning procedure      3  After establishing the desired process gas pressure level  and flow rate  start microwave power and observe the level  of reflected power     4  Adjust the tuner stubs to reduce reflected power just until the  plasma ignites  Note the tuner stub settings at the point of  ignition  Verify the settings by stopping and restarting  microwave power to see that the plasma ignition is reliable     5  W
6.  process gas     2  Preset the sliding short circuit and or waveguide tuner  or  other impedance matching device  to the adjustment settings  for optimal matching in the  pre ignition  state     3  Start the delivery of microwave power at the power level as  required to ignite the plasma     4  Adjust the tuner to the optimal setting for the  post ignition   state     5  Terminate operation by first turning off microwave power     6  Stop the flow of process gas and return the internal pressure  to atmospheric     The above procedure represents the typical case for many plasma  processes  However  the actual procedures involved can vary  depending on the waveguide configuration and the process  requirements  The following subsections describe some ways in  which the procedure can vary     Impedance Matching    For most plasma processes  the characteristic load impedances of  the  pre ignition  and  post ignition  gas states are quite different  from each other  As a result  the settings of the sliding short circuit      SSC     and or tuner for optimal matching are usually very different  between the two states  The change from one state to the other is  instantaneous  so for optimal performance the impedance matching  adjustments must also be made instantaneously     Commercially available automatic tuning systems are capable of  rapid adjustments and impedance match optimization within only a  few seconds after changes in load impedance  Such systems  eliminate the need for
7. ate the microwave generator without a properly  rated absorbing load attached  To ensure safe operation and prevent microwave  leakage  the equipment must be periodically inspected and maintained as required or  recommended           2003 2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual    Page 4       Model GA610x Series Downstream Plasma Applicator    TABLE OF CONTENTS       EGUIPMENTDESGREIPTION        s                           General Specifications    INSTALLATION agar iiicietiiiieccosieeixioi1aytscsayesEulatlsabse    Preliminary Inspection  Waveguide Configuration  Waveguide Flange Connections  Flange Alignment Pins   Vacuum Flange Connections  Water Fitting Connections    OPERATION a qx c   ioe samc UN MINE MEE    Basic Operation  Impedance Matching  Ultraviolet Radiation Safety    MAINTENONG E022 RE RuA E REENUAARARAS NAR ARERER XN ANE DI EEEN EEN ERNS    Plasma Tube O Ring Removal and Replacement  Replacement Parts       O 2003 2004 Gerling Applied Engineering  Inc     Modesto  CA    Product User Manual Page 5       Model GA610x Series Downstream Plasma Applicator    EQUIPMENT DESCRIPTION    The GA610x Downstream Plasma Applicator was designed as  general purpose tool for plasma process development  It features a  quartz plasma tube fitted between standard stainless steel vacuum  fittings which are easily disassembled for tube replacement   Standard Swagelok   fittings are provided for water cooling as well  as waveguide perforations for vi
8. de broadwalls  For  obvious reasons  the pins must not be installed such that they are  opposite each other on mating flanges     Vacuum Flange Connections    The standard model GA610x series DPA is designed with identical  vacuum ports on both sides  One port is used for introducing the  process gas and the other is for connection to the process  chamber  The DPA is symmetrical about the waveguide centerline   thus the vacuum flanges are interchangeable and can be used for  either purpose     Figure 2 illustrates installation of the GA6101 applicator with NW40  style vacuum flanges  Standard vacuum flange clamps and gasket  seals are provided with the DPA  The gas feed and chamber lid  adapters are to be supplied by the customer and shown here for  reference purposes only  While many different adapter designs are  possible  those shown are typical of many process systems     Figure 3 illustrates a similar installation of the GA6102 applicator  with 2 3 4    Conflat   style vacuum flanges  As with the GA6101  all  vacuum flange connection hardware is provided with the GA6102           2003 2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 8       Model GA610x Series Downstream Plasma Applicator    GAS FEED ADAPTER  VACUUM FLANGE  SUPPLIED BY CUSTOMER   CLAMP  2 PLCS     NW40 VACUUM FLANGE  FLANGE GASKET  2 PLCS      2 PLCS                            GA6101 DOWNSTREAM  PLASMA APPLICATOR       CHAMBER LID ADAPTER   SUPPLIED BY CUSTOMER        Figure
9. esto  CA    Product User Manual Page 6       Model GA610x Series Downstream Plasma Applicator    INSTALLATION       Preliminary Inspection    Upon arrival at the installation site the GA610x series Downstream  Plasma Applicator     DPA     should be thoroughly inspected for  damage or wear caused during shipping  Any visible damage to the  packaging material or the applicator itself should be noted and  reported immediately to the shipping company in accordance with  standard claims procedures     The following components are included   a  GA610x series Downstream Plasma Applicator  b  Product User Manual    Waveguide Configuration    The DPA can be connected to and used with any common  waveguide component having a compatible flange  see below    Mounting can be in any convenient position and orientation with  either flange positioned towards the microwave generator  Ideally   the DPA should be located as close to the tuner as possible  Figure  1 illustrates a typical waveguide configuration        MICROWAVE GENERATOR                       DUMMY LOAD    CIRCULATOR  DIRECTIONAL COUPLER  TUNE   SHORT CIRCUIT TERMINATION       Figure 1     Typical waveguide configuration for downstream plasma  processing     Waveguide Flange Connections    Both flanges of the DPA must be properly connected to another  waveguide component  Bolts and nuts must be installed at all  flange bolt holes on both flanges prior to operation  Models GA6101  and GA6102 are available with flanges designed f
10. ewing and or additional forced air  cooling of the plasma tube     To facilitate process development for different gas recipes  the  waveguide is designed with flanges at both ends  This allows  connection to a sliding short circuit  such as model GA1205  which  helps to optimize microwave coupling as the load impedance varies  with gas recipe  For basic installations a fixed position short can  also be installed in place of the sliding short circuit  Optional spacer  sections can also be installed to further isolate the o rings from the  internal source of heat  thus improving operation with higher  temperature processes    A popular feature for laboratory applications is the quick connect  waveguide flange style which allows rapid assembly and  disassembly of adjacent waveguide components using single screw  clamps  model GA8401         General Specifications    Waveguide WR284   Flanges UG 584 U with taper   Frequency 2450 MHz nominal   Input Power 1 5 kW continuous max   process dependent    and may require additional cooling     Vacuum Flanges GA6101  ISO NW40  GA6102  2 3 4    Conflat      O rings Parker Paroflour     Cooling Water 0 5 gpm min   70 psi max   50  C inlet max    Water Fittings 74  copper tubing with Swagelok   nuts and  ferrules   Construction Waveguide  Dip brazed aluminum    Vacuum flanges  Type 304 stainless steel  Water cooling lines  Copper and brass    Finish Chemical film  Black textured paint       O 2003 2004 Gerling Applied Engineering  Inc  Mod
11. hile the plasma is on  continue adjusting the tuner stubs to  further reduce reverse power  As adjustments are made  try  stopping and restarting microwave power to verify plasma  ignition  If ignition is no longer possible then return to the  previous settings     6  Repeat step 5 for SSC adjustments instead of tuner  adjustments     Ultraviolet Radiation Safety    The plasma generated within the GA610x series applicator will itself  generate ultraviolet radiation  The intensity of the radiation depends  on the plasma intensity  but in most cases it can cause burns from  prolonged exposure  The most common injury is damage to the  eyes after extended periods of direct viewing of the plasma     For safety of operating personnel  viewing the plasma should be  done only through an ultraviolet absorbing material such as  Pyrex    In any case  the viewing time periods should be minimized           2003 2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 12       Model GA610x Series Downstream Plasma Applicator    MAINTENANCE       The GA610x series Downstream Plasma Applicator operates at  extremely high internal temperatures due to the hot ionized gases  flowing in the plasma tube  Water cooling helps to dissipate the  heat near the o ring seals  while optional spacer sections help to  further isolate these temperature limited components from the  source of heat     However  regardless of the amount of external cooling of the o   rings  they are subjec
12. or used with the  GA8401 Quick Release clamp when connected to another similarly          2003 2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 7  Model GA610x Series Downstream Plasma Applicator       designed flange  These flanges can also be connected to any other  standard WR284 round flange  UG 584 U  using suitable fastener  hardware     Microwave Leakage     Regulatory limits for microwave leakage   t3 relate to standards for human safety and interference with other  electronic devices  Standards for human safety as adopted by  OSHA  the International Electrotechnical Commission  IEC  and  other regulatory agencies limit leakage to 5 mW cm  measured at 5  cm from the leakage source under normal operating conditions  and  10 mW cm at 5 cm from the source under abnormal operating  conditions  The U S  Federal Communications Commission  FCC   has established regulations limiting the emission of energy at  frequencies outside the ISM bands  All GAE waveguide  components meets these requirements when properly connected to  another waveguide component     Flange Alignment Pins    Each waveguide flange connection that uses a quick release clamp  requires two alignment pins for proper alignment of the adjacent  waveguide sections  All GAE waveguide components include one  alignment pin for each flange designed for use with quick release  clamps  Alignment pins can be installed into either of two threaded  holes centered above and below the wavegui
13. t to eventual overheating and burning at the  internal point of contact with the plasma tube  Consequently  the o   rings require regular replacement in order to provide an effective  vacuum seal and are thus considered consumable components     Likewise  the plasma tube is also subject the wear and eventual  failure due to the extreme internal temperature  Certain process  chemistries may also cause etching on internal surfaces  in which  case replacement at regular intervals may be required     Plasma Tube O Ring Removal and Replacement    The plasma tube and or o rings can be easily removed and  replaced by the user according to the following procedure  refer to  Figure 5      1  Turn off microwave power     2  Loosen and carefully remove the six SOCKET HEAD  SCREWS attaching each of the VACUUM FLANGE  ADAPTERS to the water cooling block     3  Loosen the O RINGS from around the PLASMA TUBE and  carefully slide it out of the applicator body assembly     4  Clean the areas on the water cooling blocks and flange  adapters where contact is made with the o rings  Remove all  contamination that might prevent an adequate vacuum seal        CAUTION  Gloves suitable for clean room environments should    be worn during the following two steps to prevent contamination of  the plasma tube and o rings     5  Carefully slide the new PLASMA TUBE into the applicator  body assembly  While holding the tube in place  slide new O   RINGS over both ends of the plasma and position them  snugly
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Ref. 851678 FR : Notice d`utilisation : 3 ES : Manual del usuario : 7  Siemens Recording Equipment 300 User's Manual  12089-38 - Diversey - E  Installation Manual (English)  System x3250 M4 (with IMM2 v1.34 or higher)  GE Profile PDW8060GSS Built    intext:Installationsanleitung filetype:pdf    Copyright © All rights reserved. 