CD52WH user`s manual - COP

image

Contents

1. Type of Selection of Protocols Sora p aus Integrated Protocols ji ae 1 Oud Side ae oe come AO1 OFF OFF OFF OFF ON OFF J B01 ON OFF OFF OFF OFF ON J Santachi OFF ON OFF OFF OFF ON e PELCO D ON ON OFF OFF OFF OFF J PELCO P 4800 ON OFF OFF OFF ON OFF e PELCO P 9600 OFF ON PANASONIC ON OFF ON OFF OFF ON O Longcomity OFF ON ON OFF OFF ON e HUNDA600 ON ON ON OFF OFF ON e LILIN OFF OFF OFF ON ON OFF O VICON ON OFF OFF ON ON OFF MOLYNX OFF ON OFF ON OFF ON O Number Control Definition of Keypad Operation of N Value Object Cal ee ore Set No N Preset Point 51 San sisenty Start Scan low Speed Start Patrol 52 pt of a Start Scan middle Speed Set Start Position of Scan 53 Start Scan high Speed Set End Position of Scan Power Supply of 54 Caneta Power Supply On Power Supply Off 55 BLC On Off 56 Zero luminance On Off 57 Screen Display On Off 58 D Zoom On Off 59 Focus Automatic Manual 60 Iris Automatic Manual 61 Mode of White Automatic Manual 62 Balance Interior Exterior 63 ATW One Push WB 64 1 Those Items with have memory function even the dome is switched off 2 For those cameras with menu you can use Screen Display ON to control the Menu ON OFF and use Screen Display OFF to control Screen Display ON OFF 3 For those cameras which hav
2. EE 7 8 910 Speed Done Addr ess 4 Notes parau G Wm pme 4 Speed Done Addr ess 1023 1 Addresses of the dome cameras are denoted by binary code system ON means 1 while OFF means 0 2 Above coded addresses are only from no 1 to no 20 The codes of addresses from no 21 to no 1023 can be deduced by analogue 3 The range of addresses of the spherical cameras is from 1 to 1023 Settings of communication protocol of the dome camera DIP1 DIP4 of SW2 and its default baud rate DIP5 DIP6 of SW2 In case the default baud rate of the dome camera is not in accordance with that of the controller please reset it as per the Table 3 means the protocol has been done KALATEL ON ON OFF ON ON OFF O VCL OFF OFF ON ON OFF ON O DAIWA ON OFF ON ON OFF ON O ALEC OFF ON ON ON OFF ON O Utralk ON ON ON ON OFF ON O Table 2 Protocols mentioned above are suitable for the dome camera Among them Santachi PELCO D and PELCO P have no corresponding orders for some special functions in the protocols In order to control some special functions of the spherical camera we make some functional transformation upon some common orders Normally we take Call Preset Position Set Preset position to transform and contents of order transformation are listed below
3. Abnormal self inspection Switch on again Bad connection of control wire Remove Dome Camera out of control Problems on main frame Switch on the main frame Too heavy load or longer distance of communication 1 Connect 1202 resistor to the farthest camera and let other cameras to be broken 2 Increase code distributor I Points for Attention Before installing the omni bearing intelligent unit please read the operation manual carefully The camera takes power supply of DC12V 1 2A You should assure that the power supply of the product has an input voltage with load about 12V rather than a unload voltage of 12V otherwise the camera couldn t work normally During the process of transportation storage and installation the dome should be avoided of incorrect operations such as heavy pressing strong vibration etc which can cause damage of product as there are sophisticated optical and electronic devices inside the machine Do not attempt to disassemble the camera In order to prevent electric shock do not remove screws or covers There are no user serviceable parts inside and only qualified personnel are to service the unit Always follow all electrical standards for safety when it is in operation Adopt the particular power supply which is provided with the dome RS 485 and video signal should keep enough distance with high voltage equipments and cables when they are in transmission
4. ON ON ON ON ON ON Table 1 For Example communication protocols integrated inside the spherical camera and the baud rates can be selected from 24000 bps to 19200 bps 5 Selectable Optical Zoom Range of Camera Times of Optical Focus Range Lowest Luminance Zooming 16x 3 9 f6 3 mm 1 Lux F1 4 18x f4 1 f73 8 mm 1 Lux common type 0 01 Lux day amp night type 22x f4 88 mm 0 2 Lux F1 6 1 3s 23x f3 6 82 8 mm 1 Lux Common type 0 01 Lux day amp night type 25x f3 6 f90 mm 1 Lux Common type 0 01 Lux day amp night type III Settings of Special Camera Before installing the spherical camera please confirm the communication protocol and baud rate the master controler in the system uses then set the coding switches on the back of the camera to be identical with that of the system in which SW1 is for address of the spherical camera and SW2 is for communication protocol and baud rate see attached tables 1 2 and 3 RT 1234 3456789 10 Protocol Sel ec Speed Done Address Sel ect 3 ID COLE Set o e JP 120Q terminal resistor is opened for RS485 bus System control wre 123 ee JP 120Q terminal resistor is connected on RS485 Bus Coding Switch 4 5 6 Baud Rate 2400 bps OFF OFF 4800 bps ON OFF 9600 bps OFF ON 19200 bps ON ON IV Steps of Installation
5. X 1 Mounting Base k 2 Outer Tube 7 3 Shading Cover N 4 Outer Cover 5 Camera 6 Connecting Cable 2 Y Dimension Drawing Carefully read the operation manual and the points for attention Carefully set the communication code baud rate and address of the dome camera and make confirmation they are correct Take out the plug of the dome camera and connect external power supply RS485 and video wires as per marks on the plug Take care that the power supply of the dome camera is DC12V 1 2A and adopt the particular power supply which is provided with the dome camera Red DCI2V Black GND Orange RS485 Yellow RASS VIDEO Take out the mounting base from the spherical camera thread the connecting wire from behind through the central hole of the base Fix the base by three screws on the ceiling as per the drawing and connect the wire with the ball Aim the latch in the ball with the notch on the base as per the drawing and mount the ball upward to the position and turn it clockwise until the spring sheet on the base takes effect In case the wire could not come out from behind the ceiling you can open a hole on the edge of the casing for running of the wire Installation Drawing color TV omni bearing dome P T and multifunctional decoder into a whole It can largely reduce connection and installation processes of components in the system rise up reliability of the system and facilitate installation and mai
6. are beyond the limited stipulations 8 Do not let the video camera aim at the sun or the object with extreme light whatsoever it is switched on or not Do not let the video camera aim at or monitor bright and standstill object for a long time 9 Do not use aggressive detergent to clean the main body of the video camera Wipe dirt with dry cloth If needed mild detergent can be used suitably 10 Operate the intelligent high speed spherical video camera with great care to avoid shock or vibration It operate incorrectly machine could be damaged 11 Install the video camera in the place where endurance should be enough large 12 Should be dust on the lens you should wipe it with special lens tissue II Description of Functions The dome camera is a hi tech CCTV product which incorporates V Main Technical Data Image Inductor 1 4 Color CCD Effective Pixels 752H X582V 440000pixels PAL Synchronous System Internal Synchronization VF Output Compound Signal 1 0Vp p 75 Q White Balance Automatic Manual Specifica Power Supply DC12V 10 1 2A tions Power Consumption 12VA Weight 2Kg Mounting Style Ceiling or ceiling hanging style Relative humidity 10 75 under no condensing Operation i Temperature oe Scan System 15 625KHz H 50Hz V Horizontal Resolution 480 TV lines Camera Signal Noise ratio Larger than 48 db Function
7. Electronic Shutter 1 3 1 10000 seconds Lowest Temperature 1Lux AGC ON L Zooming Range 18 X Optical and 12 X Digital ens Iris Automatic Manual Data Focus Automatic Manual Basic Horizontal Turning 0 15 s constant P T 15 s fixed Function Vertical Turning 0 15 s constant P T 15 s fixed s of Preset Positions 64 presets max Spherica Patrol Function 1 Camera At best 6 cruises VI Analysis of Normal Troubles Problems Possible Causes Remedies No action and roe supply damaged Replace insufficient power images when So Wrong connection of power power is switched supply Correct Oe Faults in engineering circuits Remove Abnormal Mechanical fault Repair self inspection Tilting camera Place uprightly Images with roaring sound of Insufficient electrical power Replace with qualified power supply and let it close to the the motor spherical camera Normal Wrong connection of VF circuit Correct self inspection Bad connection of VF circuit Remove but no images Camera damaged Replace Wrong connection of control i Correct signal wire Successful Mismatched address of spherical Reselect self inspection but out of control camera Mismatched protocol Adjust protocol to match with the controller and switch on again Bad connection of VF circuit Remove Images unstable aE Insufficient electrical power Replace
8. Precautions for anti lightning and anti surging should be taken if necessary Normal problems and their causes and remedies mentioned above are only for reference Should you meet other special problems you can ask for technical support from your dealer directly SIX INCHES DOME P T Please read the operation manual carefully before installing and using this unit
9. e no Zero Illuminance or the function of Zero Illuminance is automatically switched without control and then above Zero Illuminance is invalid 4 Notes to Patrol Function of the dome camera Automatically scan from no 1 to no 16 preset points one by one If some points do not have been preset or are cleared out after presetting they will be bypassed when patrol is carrying out The dwelling time between to preset points is 4 seconds 3 The Patrol function of the dome camera can be carried out by presetting no 51 positions 5 Notes to Scan auto pan Function of the dome camera The dome camera makes automatic scan between two specified positions The speeds of scan are divided into three levels You can call no 51 52 and 53 preset positions to start scan at speed of 1 5 sec 5 sec and 10 sec separately The dwelling time between the Start Point and End Point of scan is 3 seconds 6 All notes mentioned above are supplementary descriptions under high speed All original operations of the control system are unchanged Settings of Communication Baud Rate of the dome Camera JP1 is jumper for the terminal resistor JP1 is the 120 Q terminal resistor for RS485 Bus When short circuit terminal is set between 1 2 the 120 terminal resistor is opened while it is set between 2 3 the resistor is connected Take care that on RS 485 Bus only one farth
10. est spherical camera has the terminal resistor connected while other devices should have their terminal resistors opened Settings of Addresses of dome Cameras Dome States of Coding Switches Address 1st 2nd 3rs 4th Sth 6th 7th 8th 9th 10th j ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF OFF OFF 1023 ON ON ON ON
11. ntenance Therefore it has advantages of beautiful appearance compact structure and easy operation Integrated Multi Protocol Decoder a With built up decoder and integrated multi protocol it can integrate 16 kinds of communication protocols in maximum As its baud rate of communication can be adjusted it is compatible with main domestic and foreign systems by easy setting inside the spherical camera so it has stronger versatility b RS485 serial control addresses of the dome camera 1 1023 Integrated Omni bearing dome P T a Turning 360 horizontally and continuously with unlimited positions PAN speed range 0 15rad s constant speed dome PAN 15rad s turning 0 90 vertically with a speed 0 15rad s constant speed dome TILT 15rad s b Running stably at low speed with super lower noise Pictures have no shaking c the location precision up to 0 2 High Intelligent Degree a Support the dome camera to scan horizontally between two points and scan speed can be modified b Data can be stored with powerless memory Newly Added Functions a Flexible and Convenient Application there are many 6 The product should be indoor installed and operated to avoid rain and moisture Do not use it in wet places If outdoor installation is needed the closed protect cover should be used and it is absolutely prohibited to use it in open air independently 7 Do not operate it in case temperature humidity and power supply

Download Pdf Manuals