Home
User Manual
Contents
1. Rapid cool cycle also Programming the device To operate the device as desired the device must be programmed The programming procedure is described below After powering ON the device the following screen is displayed ON DELAY 3 MIN SETUP 220V The message displayed above means that the device is in the 3min delay mode after being powered ON amp the current power supply voltage is 220V To program the device press key1 for 3 4 seconds continuously The following screen is now displayed ENTER PWD 0000 SET INC DCR The correct password must be entered to program or re program the device To enter the password press Key2 or key3 to increment the 1 digit displayed until the correct digit is displayed To enter the correct digit Displayed into the memory press key1 Eg if the first digit of the password is 3 then press key2 or key3 Until the first digit displayed is 3 then press key1 to enter 3 into the memory The other 3 digits must also be entered into the memory similarly If the password entered is incorrect then the following screen is displayed WRONG PASSWORD The factory setting of the password is 0000 g 0 SYSTEMS Prosperity Through Energy Saving If the password entered is correct the next screen is displayed as follows PASSWORD OK SETUP CH PWD To change password press key3 when the above screen is displayed or key1 to program the device parameters The procedure for changing the
2. of human beings amp control the AC resulting in saving of power amp money RTC this device is programmable for a max of 8 set points defines the ON time amp OFF time of the device The timing is programmable for a max 24 hrs Starting from 00 hrs to 24 hrs the AM amp PM style is not used but continuous time of up to 24 hrs is programmable KEY BOARD The keyboard has 3 keys with the keys being used for the function being displayed on the screen The keys from the left to rightmost direction are referred to as SET key INC key amp DCR key g 0 SYSTEMS Prosperity Through Energy Saving OPERATING MANUAL FOR STELLAR SINGLE AC TEMP BASED WITH PIR SENSOR AND RTC REAL TIME CLOCK The device must be programmed as per your requirements for use The procedure for programming is as follows SET UP PROCEDURE ON DELAY 3MIN SETUP DIS 28 C The above screen display means that the device is executing the 3 min delay after power start up and the current temp is 28 c To program the device the setup procedure must be selected using the SET key on the keypad for about 3 to 4 seconds continuously The next screen is displayed as follows ENTER PWD 0000 SET INC DCR The correct password must be entered to program or re program the device To enter the password press INC key or DCR key to increment or decrement the 1 digit displayed until the correct digit is displayed To enter the correct digit displayed int
3. password is as follows Press key2 or key3 until the desired digit is displayed in place of the first digit then press key1 to enter this digit into the memory The second digit to fourth digit are also entered into the memory similarly The programming of the parameters is done as follows RAPID COOL 30 MIN SET INC DCR Press key2 or key3 until required rapid cool time of 30 45 60 min is displayed Press key1 when the Desired time of rapid cooling is displayed Eg if the desired rapid cool time is 60 min then press key1 to enter 60 min into the memory The next screen display is SETUP MODE EXIT SET VSET The device has 36 preprogrammed saving cycles selectable by the user according to percentage or timing g 0 SYSTEMS Prosperity Through Energy Saving To select the cycle depending on percentage of saving press key2 To select the cycle depending on the timing press key3 Depending on the option selected the screen display amp the procedures are mentioned below On pressing key2 the screen now displays AA M BBM SAVE 22 SET INC DCR The AA min displays the ON time of the AC The BB min displays the OFF time of the AC The digits after SAVE indicate the percentage of saving Pressing key2 or key3 changes the value displayed to the next value When the desired ON time OFF time amp percentage of saving is displayed press key1 to enter the values displayed into the memory The screen no
4. AC is started to reach the set temp For RT C Real Time Clock Set Point This Device is programmable for a max of 8 set point set point defines the ON time amp OFF time of the device The timing is g 0 SYSTEMS Prosperity Through Energy Saving programmable for a max of 00 Hrs to 24 Hrs The AM amp PM style not used but continuous time of up to 24 Hrs is programmable DIS The display function is referred to as DIS on the LCD screen On activating it the programmed parameters are displayed on the screen one after the other Programming the RTC HR MM SS DAY SETUP DIS 220V The screen shows current timing the present day amp the current value of supply voltage To enter Set up mode press SET key for about 3 4 Sec the display ENTER PWD 0000 SET INC DCR After entering correct password PASSWORD OK SETUP TIME CHPWD Press INC key TIMER SETUP SETUP TIME CHPWD g 0 SYSTEMS Prosperity Through Energy Saving Press INCR key DECR key until desired time of seconds is displayed SET key SEC 00 59 SET INCR DECR Press INCR key DECR key until the desired time in minutes is displayed SET key MIN 00 59 SET INCR DECR Press INCR key DECR key until desired Hours is displayed SET key HR 00 23 SET INCR DECR Press INCR key DECR key until des
5. elp you to familiarize yourself with the function amp programming of the device Please read this manual carefully amp preserve it for future use In case of any doubts please contact us at Tel 25420169 Email customercare atconsystem com Understanding the basic terms PASSWORD A 4 digit code used to access the programming routine amp program the device as desired Unless a valid password is entered the device cannot be programmed RAPID COOL This is the maximum of time for which the AC stays ON continuously after being powered ON to reach the set temp KEY BOARD The keyboard has 3 keys being used for the function displayed on the screen The keys from the left to rightmost direction are referred to as key 1 key 2 amp key 3 respectively ON TIME The maximum amount of time for which the AC will be continuously ON is referred to as ON time This time is programmable by the user OFF TIME The maximum amount of time for which the AC must be OFF before being powered ON again is referred to as OFF time CYCLE TIME The maximum amount of time for which the device has to continuously run the AC by controlling Its ON amp OFF time cycle is known as cycle time After completion of the CYCLE TIME the AC is powered OFF To start the AC the device must be switched OFF amp ON from where the device starts executing the programmed Cycles g 0 SYSTEMS Prosperity Through Energy Saving NOTE The cycle time includes the
6. g 0 SYSTEMS Prosperity Through Energy Saving USER MANUAL FOR STELLAR 5505 5514 5523 5532 Dear customer Thanks for purchasing the STELLAR ENERGY SAVER This device helps you to save energy amp money It is also helpful in controlling the operation of your ac more efficiently This user manual will help you to familiarize yourself with the functions amp programming of the device Please read this manual carefully amp preserve it for future use In case of any doubts please contact us at Tel 25420169 or e mail customercare atconsystem com Understanding the basic terms The following terms are used in this manual with reference to the device or its programming so please read and understand these terms well PASSWORD A 4 digit code used to access the programming routine amp program the device as required Unless a valid password is entered the device cannot be programmed RAPID COOL This is the maximum amount of time for which the ac stays on continuously after being powered on to reach the set temperature MODE This device can be operated in four modes by the user Viz VIP ECO LO ECO HI SLEEP These modes offer different levels of energy saving with slight variation in comfort level TEMP SETTING The required temp can now be set in the range of 16 c to 35 c in steps g 0 SYSTEMS Prosperity Through Energy Saving PIR The device automatically detects the presence amp absence of movement
7. ired day is displayed SET key DAY 1 7 MON SET INCR DECR Screen display is HR MIN SEC MON SET INCR DECR Press SET key Use password routine ENTER PWD 0000 SET INC DEC g 0 SYSTEMS Prosperity Through Energy Saving Press INC key DEC key until desired rapid cool time is set SET key RAPID COOL 30 MIN SET INC DEC SET key to exit to main screen or press INC key for setting cycle time SETUP MODE EXIT SET VSET Press INC key DCR key until desired option is displayed SET key 18M 05M SAVE 20 SET INC DCR Press SET key and show steps invalid data S1 HH MM HH MM SET INCR DECR Press INCR key DECR key until START amp STOP value is displayed Hrs amp Min Then press SET key Similarly for S2 to 88 the procedure is repeated with different value the user may desire to enter NOTE If STOP time is earlier then START time it is considered invalid data by the device amp the next screen is not displayed The device is now programmed and ready for use g 0 SYSTEMS Prosperity Through Energy Saving USER MANUAL FOR STELLAR T 36 AND STELLAR TR36 Dear Customer Thanks for purchasing the ATCON STELLAR energy saver This device helps you to save energy amp money It is also useful in controlling the operation of your AC efficiently This user manual will h
8. o the memory press SET key Eg if the first digit of the password is 3 then press INC key or DCR key until the first digit displayed is 3 then press SET key to enter 3 into the memory The other 3digits must also be entered into the memory similarly If the password entered is incorrect then the following screen is displayed g 0 SYSTEMS Prosperity Through Energy Saving WRONG PASSWORD The factory setting of the password is 0000 If the password entered is correct the next screen is displayed as follows PASSWORD OK SETUP CH PWD To change password press DCR key when the above screen is displayed or SET key to program the device parameters The procedure for changing the password is as follows Press INC key or DCR key until the desired digit is displayed in place of the first digit then press SET key to enter this digit into the memory The second digit to fourth digit are also entered into the memory similarly The programming of the parameters is done as follows RAPID COOL TIME SETTING The following screen is displayed if the password entered is ok RAPID COOL 30 MIN SET INC DCR g 0 SYSTEMS Prosperity Through Energy Saving Press INC key or DCR key until required rapid cool time of 30 45 60 min is displayed Press SET key when the desired time of rapid cooling is displayed Eg if the desired rapid cool time is 60 min then press INC key or DCR key until 60 is displayed Now pres
9. s SET key to enter 60 min into the memory The next screen displays The Mode can be now set The 4 modes are VIP ECO LOW ECO HI SLEEP By pressing INC key or DCR key the various modes are displayed When the required mode is displayed press SET key to enter the selected mode into the memory The next screen display is SET INC The required temperature can now be set in the range of 16 C to 35 C in 0 5 steps Press INC key or DCR key until desired temp is indicated on the screen then press SET key to enter the desired temp into the memory g 0 SYSTEMS Prosperity Through Energy Saving The next screen display is CYCLE HR SET INC The required cycle hour time is now programmable By pressing INC key or DCR key the cycle hour value changes ranging from 00 hrs to 24 hrs in 30 min steps Press SET key to enter the displayed value into the memory The next screen display is ATM_OFF ATM SET INC DCR Press INC key DCR key to select the ATM or OFFICE mode when desired mode is displayed press SET key to enter the desired mode into the memory ATM MODE In the ATM mode Temp of 27 c is maintained in the absence of any movement If any movement is detected the AC is started to reach the set temp Eg set temp is 24 c OFFICE MODE In the OFFICE mode when there is an absence of movement the AC is powered OFF after 10 min amp if any movement is detected the
10. w displays the CYCLE HR option But before that we will mention the VSET or timing cycle option programming which is selected by pressing key3 The screen now displays ON TIME AA MIN CC SET INC DCR The ON time is selected now by pressing key2 or key3 until the required ON time in the range of 15 min to 30 min is displayed When the desired ON time is displayed press key1 to enter the displayed time into the memory The screen now displays OFF TIME BB MIN CC SET INC DCR g 0 SYSTEMS Prosperity Through Energy Saving The OFF time is now selected by pressing key2 or key3 until the required OFF time in the range of 5 min to 15 min is displayed When the desired OFF time is displayed press key1 to enter the displayed time into the memory The screen now displays CYCLE HR DD EE SET INC DCR The cycle hour time can now be programmed DD displays the hours amp EE the minutes of programmed cycle time Pressing key2 or key3 changes the timing in the range of 00 hrs to 24 hrs in 30 min steps When the desired cycle time is displayed press key1 to enter the displayed time into the memory The programming of the device is now complete amp the device starts functioning as programmed