1. amp Cisco 2600 HyperTerminal E E 2 10 x File Edit View Call Transfer Help nd File al se B Receive File Capture Text Send Text File Capture to Printer Sends a file to the remote system Figure 2 63 Send File Menu Command 50 8100 Mobile Device Test System LTE Product Update 17 In the Send File window click the Browse button and select the lt 8100 LTE 4 4 0 18 19 20 21 22 23 24 25 Installer Root gt Router Switch Config Files Cisco2600 txt configuration file Figure 2 64 Selecting a File Click Send and wait for the transfer to complete Once the transfer is complete HyperTerminal should display text similar to the following 6784 bytes copied in 56 084 secs 121 bytes sec Spirent router Restart the Cisco Router and enter the following command reload HyperTerminal now displays Proceed with reload confirm Press y The router restarts Press Enter and verify the prompt displays the configuration file part number with the correct revision 64_005413_vXX The upgrade is now complete 2 9 3 Updating the Dell 6248 Switch L Connect the serial cable between the 9600 N 8 1 port on the rear of the switch and the COM1 serial port on a PC This is a standard 9 pin serial cable is included in the box with the switch Using the HyperTerminal application or equivalent communication
2. S Users WIN AVVTIR 75D0G Users To change permissions click Edit Edit Permissions for Users Allow Deny si Full control Modify Development Library Services Read amp execute File Folder List folder contents Date modified 12 16 2011 10 14 AM Read Write For special permissions or advanced settings anced click Advanced ony Figure 2 17 Properties Window User Permissions 4 Click the Advanced button and select the User Permission entries corresponding to Read amp Execute 5 Click the Change Permissions button as shown in Figure 2 18 PA Advanced Security Settings for Development Library Services P ENTO Auditing Owner Effective P eee To view details of a permission entry double click the entry To modify permissions click Change Permissions Object name C ProgramD ata Spirent Communications Development Library Services type Name Pemisin_ Inherited From Apply To Allow SYSTEM Full control C ProgramD ata This folder sut Allow Administrators WIN AVYTIR75DOG Ad Full control C ProgramD ata This folder sut Allow CREATOR OWNER Special C ProgramD atas Subfolders anc Users WIN AVVTIR75DOG Users Read amp execute C ProgramData This folder sub Users TWIN AVYVTIFA l 3 C ProgramD ata This folder and gt IV Include inheritable permissions from this objects parent Menta ae cea __ Figure 2 18 Changing the Read amp Execute Permiss
3. Qui O P seve ras E E adess neon Tie a LAN or High Speed Internet Network Tasks Local Area Connecti aha F ed S rir F eL a Fire Feber Bre e a a LE Ria i F E SO La F gal Vat office network Change Windows Firewall settings Disable this network device ig Change settings of this connection Figure 3 10 Network Connections Window 64 8100 Mobile Device Test System LTE Product Update 2 Right click Local Area Connection and select Properties from the menu The Local Area Connection Properties window displays as shown in Figure 3 11 3 Deselectthe Internet Protocol TCP IP option as shown in Figure 3 11 Local Area Connection 3 Properties F X General Advanced Connect using 84 LTE USE NDIS 2 This connection uses the following items W Microsoft TCP IP version w Network Monitor Driver L 35 Internet Protocol TCFAP r H Install Uninstall Properties Description Allows your computer to access resources on a Microsoft network TO Show icon in notification area when connected i Notify me when this connection has limited or no connectivity OF Cancel Figure 3 11 Local Area Connection Properties Window
4. CTR TE Udiy Sint Ciani TE ob Vian VIZIO pi o Dupa Lisie Fs Gi F Calibration Ciir hat File Protti CAP apart pen Commaracotioe Devel Lory Sees Sea Paham Fieri Berio Calda Ciir Wied e Gp haay LTE_TP Sea Liek bose ba eroul s E Dy LTE_TA Sue 1 3 Die LTE TP Suda wi 2 Figure 3 8 Setting Platform File Parameters 6 If you are running the LTE RF Performance Module select the B100 tab in the new Platform File 8100 Mobile Device Test System LTE Product Update 63 7 Configure the SR8048 Test Configuration options for the system as shown in Figure id Le My Sierra NICue gi COMA LTE Mobilky Verfication ses f COMA LTE Mobility Verification HTC ThunderBok plm COMA LTE Mobity Verification LG Revolution pim CDMA LTE Mobilty Verification LG VL600 pim PlatformFile1_5500 plm E 1 Spirent LTE NE IP Addre Handover UMTS 5 to Handover UMTS 5 to t 2 COMA LTE Mobity A ddie E Ly DataRety LTE O 2 Test Configuration Unit 8048 F a B Data Throughput LTE O emo EU LTE UMTS Mobity SR8048 Fiter Present 2 LTE UMTS Mobility SR8068 Present pid ma Handover Ga if i 3 ri o a 3 Agilent 8960 Wireless Communications Test Set r ia Agilent 8950 Wireless Communications Test Set Present ra i i Antenna Configuration 1 sa Handover UMTS 2 to i 4 Agilent U2001A Power Sensor mi Handover UMTS 2 to tac Tesi USB mi
5. NOTE Contact your local Spirent Sales Manager if new or additional passwords are required for the updated features 3 Delete all older platform files In Test Manager select File Open gt Platform File 4 Create a new platform file In Test Manager select FilesNew gt Platform File Refer to Section 0 for details on creating Platform Files 5 Update all UE Files from previous versions In Test Manager select File Open gt UE File and save the old UE Files again 6 Update all Session Files from previous versions In Test Manager select File Open gt Session File and save the old Session Files again 7 Runa System Calibration for the B Series platform and or the B 100 platform 8 Close Test Manager 8100 Mobile Device Test System LTE Product Update 19 2 4 6 Completing eAirAccess Configuration 1 Launch eAirAccess by double clicking the desktop icon 2 Select Help gt Enter Password The Passwordwindow displays as shown in Figure 2 11 3 Enterthe appropriate password and click OK GE PasswordDig Application Passwords Password entered correctly press OK to save OK Password entered corectly press OK to save Cancel ZI SPIRENT Communications Serial Number 4A7F11E1 Features Available Expiration Date Hardware Key found Enter password Figure 2 11 Entering the eAirAccess Password 4 Close eAirAccess 2 4 7 Completing AirAccess C2K Installation 1 Launch AirAcces
6. 2 Transmitter Tests 2 2 8 Configured Output Power TP1 1 2 5 UMTS LTE Mobility There are no new features included in this release of the UMTS LTE Mobility Test Packs 8100 Mobile Device Test System LTE Product Update 5 1 3 Maintenance Updates 1 3 1 CDMA LTE Mobility The following maintenance updates have been added to the CDMA LTE Mobility Test Packs Supports continuing to run full test case if intermediate step fails Supports not verifying data continuity Supports delay while switching RAN emulators Supports provisioning APN in a test case parameter 1 3 2 Data Retry LTE The following maintenance updates have been added to the Data Retry LTE Test Packs Supports UE automatic attach to internet PDN Supports enhanced parameters for multi PDN settings 1 3 3 Data Throughput LTE The following maintenance updates have been added to the Data Throughput LTE Test Packs Test Manager Event window results enhancement Benchmark Report enhancement Detail Report enhancement Advanced Channel Models enhancement 1 3 4 RF Performance LTE The following maintenance updates have been added to the RF Performance LTE Test Packs Failures seen with VZW Supplementary RF Conformance 2 4 Spurious Emissions Band UE Coexistence and VZW Supplementary RF Conformance 2 9 Spurious Emissions Band UE Coexistence have been addressed with this release of LTE RF by introducing an
7. Handover UMTS 5 to B 5 Calibration m Handover UMTS 0 Calbralion Data Fie Path C Program Fles Spirent Commurications T est Manager M anages Platioems 81 00 8 100 Calibration 81 00 8 100 Calibvation xmi ra Handover UMTS 2 to Calibration Signal Source Address 192 168 0 112 wa Handover UMTS 2 to Calibration Wizard Click here to execute ve ri ri Redirection UMTS 2 t A Rarirertinn LIMTGIA I Figure 3 9 SR8048 Test Configuration Options 8 Ifyou are running C2K SVLTE configure the Agilent 8960 options in the Platform File 9 When all options have been configured save the Platform File by selecting File Save in Test Manager 10 When executing the tests ensure that all test cases reference the Platform File you have just created 3 6 Disabling Internet Protocol on the UE Network Connection When running the LTE RF test cases the UE is connected to the Controller PC for automation control LTE UEs often establish an IP address automatically when connected to the USB port on the PC This can cause Stability issues while running LTE RF test cases To prevent this from occurring perform the following steps to disable internet protocol on the UE network connection 1 From the Control Panel select Network Connections and locate the UE Local Area Connection as shown in Figure 3 10 a Network Connections Ble Ede yew Favorites Tools Advanced Help ae
8. Start Test Manager and select Help About Passwords Click the Export button and use the file browser to export the passwords to passwords csv Close Test Manager 2 4 2 Updating Intrig Data Monitor li A Uninstall any previous versions of IDM by selecting Start Add or Remove Programs Navigate to the 8100 LTE 4 4 0 Installer Root eAirAccess Controller PC IDM folder Execute idm x x x exe and accept the defaults Modify the registry entries after IDM is installed a Select Start Run Type regedit and press Enter Windows 7 Users Type regedit in the Search field and press Enter If the UserAccount Controlwindow displays click Yes to proceed Expand HKEY_LOCAL_MACHINE SOFTWARE Intrig Right click the DM folder and select Permissions Select the Users account and under Permissions select Allow for the Full Control option as shown in Figure 2 4 Click Apply and then OK 14 8100 Mobile Device Test System LTE Product Update N Permissions for IDM xi Security Group or user names amp CREATOR OWNER SA SYSTEM S Administrators WIN AVYVTIR75D0G Administrators R Users WIN AVYTIR75DO0G Users Permissions for Users Allow Deny Full Control Read Special permissions For special permissions or advanced settings Advanced click Advanced Learn about access control and permissions Cancel Apply Figure 2 4 IDM Permissions Window 2 4 3 Updating Compone
9. grants a nonexclusive license to use Product Software on one equipment personal computer and or laptop whenever lthe user of both is the same person If a local network is used an appropriate number of licenses for every equipment has to be acquired License will terminate if Buyer discloses the Software to others without IATA Wirelesce s consent Rack im comes nf the Software mav he If you accept the terms of the agreement dick the check box below You must accept the agreement to install LTE E2010 Signalling Unit Software Installer Click Next to continue I accept the terms of the License Agreement 1 I nl Figure 2 32 E2010 Software License Agreement Window 3 In Choose Components window select all components except Overwrite calibration as shown in Figure 2 33 Click the Install button LTE E2010 Signalling Unit Software Installer Setup Choose Components MG Choose which Features of LTE E2010 Signalling Unit Software A T4 D Installer you want to install Wieriess Check the components you want to install and uncheck the components you don t want to install Click Install to start the installation SU Manager Toolbox 4 0 10 Calibration Agent YZ Overwrite calibration E7010ComDriver Mon E7010ComDriver Mult E7010 SW Upgrade pri Ca porro gt Select components to install E7010 Release Packad a Pasig QUE MOUSE Space required 155 0MB Figure 2 33 Choose Components Window 4 In the Default AT4
10. 1 Using Windows Explorer navigate to the C ProgramData Spirent Communications folder as shown in Figure 2 16 Spirent Communications oo Computer OS C ProgramData Spirent Communications X Search Spirent Organize v Open Include in library Sharewith v Burn New folder Documents Name Date modified Type size ad Music J AirAccess C2K 12 16 2011 10 12AM File folder t Pictures di AirAccess WCDMA HS 12 16 2011 10 13 4M File folder E Videos BB Devel pment Library Services amp Homegroup Test Manager 12 16 2011 10 14AM File folder ala Computer amp 05 c di Apps d AT4wireless Ji del di Drivers Figure 2 16 Spirent Communications Folder 2 Right click the Development Library Services folder and select Properties from the menu In the Propertieswindow select the Securitytab 3 Select the Users group to view the Permissions as shown in Figure 2 17 22 8100 Mobile Device Test System LTE Product Update yp MAL VELLA RATIO ACFIO CULI IVi 41 TRE hue gt A Develo pment Library Services File folder di Test Manager 12 16 2011 10 14 AM 816 2011 10 14 AM File folder M Developn gt t Library Services Properties General Sharing Security Previous Versions Customize Object name C ProgramData Spirent Communications Develop Group of user names CREATOR OWNER amp 2 SYSTEM 82 Administrators WIN AVVTIR75D0G Administrators
11. 4 21 IP 6 FTP Server ii General O Advanced Virtual Server FTP E Public Path I Server IP and port Modify ir File and Directory C Enable SSL for virtual server Y Security O O External User Authentication O Server Bandwidth D Maximum download bandwidth KB s 0 Maximum upload bandwidth KB s 0 o Set bandwidth by IP address range Setup Server Connection Limits A Maximum concurrent users 0 A Maximum logins from the same IP 0 Cancel Figure 2 25 Enable Anti idle Scheme Option 5 Click OK to close all Xlight windows 8100 Mobile Device Test System LTE Product Update 27 2 7 Updating the EPC Server NOTE If the steps in Section 2 4 7 have been completed you can skip this section 1 Fromthe Controller PC navigate to C Program Files Spirent Communications SR3600 x x x as shown in Figure 2 26 If there is more than one folder open the most recent File Edit wiew Favorites Tools Help Back a po Search Wey Folders Eta Address MD C Program Files Spirent Communications SR 360019 5 0 a fa x Folders Mame O Test Configuration Files a E coast_9 5 0 45 2 tsu SimGEN c S5R3600 exe 9 Spirent AT Control D Spirent Data Client 9 Spirent SMLC Emulator E Di 5R3600 Di 9 0 0 3 5 0 D TCU2 Wrapper D Test Manager D Universal DM 42 utilities Figure 2 26 SR3600 Folder 2 Execute t
12. COVER 60 4 9 WINGOWS Server 200 Saida rcposanirna 61 3 5 Creating a New Platform File cccecssceccsceccscssceceseeccscssescsseceese 62 3 6 Disabling Internet Protocol on the UE Network Connection 63 1 Introduction _ rlrc pPpeeEIE rr_ 1 1 Overview This Product Update contains information on the modifications of the Test Packs supported on the 8100 Mobile Device Test System from the version 4 3 1 to version 4 4 0 The Test Packs supported on the 8100 Mobile Device Test System v4 4 0 are e CDMA LTE Mobility v1 3 e Data Retry LTE v1 3 e Data Throughput LTE v1 4 e RF Performance LTE v1 5 e UMTS LTE Mobility v1 0 8100 Mobile Device Test System Radio Access LTE v4 4 0 consists of the software components listed in the table below Software Version E2010S Driver V1 2 8 0008 E2010S Driver V2 2 8 0008 Intrig Data monitor 1 2 9 RF Performance LTE 1 5 370 2 8100 Mobile Device Test System LTE Product Update Software Version Spirent AT Control installed on Client 15 25 Laptop Spirent Data Client installed on the 1 12 213 Controller PC Client Laptop and Application Server Spirent EPC Software 10 0 0 48 paw 19 tsu Spirent WCE IAPI 3 51 034 Spreadsheet Report Engine 1 5 67 SR5500 TestKit 3 51 002 TCU2 Driver 1 0 16 UMTS LTE Mobility 1 0 6 1 1 2 New Features 1 2 1 CDMA LTE Mobility The f
13. Controller PC Windows 7 Client Laptop Select Start gt Control Panel gt System and Security Windows Update gt Change Settings The Windows Update Change Settings window displays Under the mportant Updates section select Never check for updates as shown in Figure 3 5 Windows Update Change settings ul Choose how Windows can install updates When your computer is online Windows can automatically check for important updates and install them using these settings When new updates are available you can also install them before shutting down the computer How does automatic updating help me Important updates 3 Never check for updates not recommended Install new updates Every day r at 3 00 AM Recommended updates Give me recommended updates the same way I receive important updates Whe can install updates Allow all users to install updates on this computer Note Windows Update might update itself automatically first when checking for other updates Read our privacy statement online Figure 3 5 Windows Update Change Settings Click OK to save the changes and exit the window If a Windows update is turned off Click to turn on message displays on the desktop ignore it 8100 Mobile Device Test System LTE Product Update 61 3 4 3 Windows Server 2008 If you are running Windows Server 2008 on the Applications Server perform the following steps 1 Select Start gt Control PanelySy
14. UMTS WCDMA Cell Configure td Redirection UMTS 2 t Inform 12 20 2011 9 25 02 AM Step 3 Configure LTE SIBE Starting execution Figure 3 7 Platform File Menu Item 2 Under Available Instruments enable all configured instruments 3 Under Network Configuration configure the available network options for the specific module to be tested Under PDN Gateway enter FD00 0 20 1 0 0 1 3 for the IPv6 address as shown in Figure 3 8 5 Under SR8078 Test Configuration Unit select the LTE Mode Configuration file applicable to the test theme ERE Be Ee Ye Foeute Bepot ip j3 3 We A b 8 B fera blu a GOMA IT Mobily Verification i Fie orai 9 metin 000700 Proto o LTE Mobility Verification HIC Thundertioli plim x Ti E Sue T Available Instrumenta E Lg DIMA T mechan Fra E2005 CE Eraikia Dog Data Pete LTE g Fae E j Data Tha LT 5 E True iar LTE UHT May AES HI Enabled true ip LIE 10416 Mey SAMS Ri Unable True af Handover UTSA f SII ii fr ml Handra UMTS ia TA Fuk ni Handvem UMTES in n indi Horwkirosr UM TSS te zl wt Honken UTS al wl Harket Ubi Tac mil Harden LTS to al Hankas LITE TI 15 ni Hacks UMTS ii Harder UHTHH 7 m ember UMT SNA i Madeschon UMP Sat mi lesion UAT HREJE mi Neked UTE we Arsia LIE e us ni ni Rodio LIE are we Prenestini LIEN bo ie Hebein LIE to Dj Vesron Compliance les Piana
15. keypad to enterthe hostname To erase the current hostname press Editing Keys gt Clear Text Press Enter Set the LAN Config Manual DHCPto Manual Press IP Address and enter 192 168 0 112 Use the left and right arrow keys to move the cursor Use the up and down arrow keys front panel knob or numeric keypad to enter an IP address To erase the current IP address press the Clear Text soft key Press the Proceed with Reconfiguration soft key and then press Confirm Change The ESG1 instrument now reboots Repeat the above steps for the ESG2 instrument using 192 168 0 113 for the IP address ESG2 is the unit connected to P16 of the SR8048 TCU 2 10 3 Downloading Waveform Files to the ESG After the ESG1 restarts perform the following steps 1 2 From the Controller PC open the Command Prompt Type CD C Program Files Spirent Communications TestManager Modules RF LTE Interference Waveform Files When you are prompted to enter the Username and password keep the fields blank and press Enter Type bi on the FTP prompt and press the ENTER key Type ha on the FTP prompt and press the ENTER key Type put ATSC bin user waveform ATSC bin and press the ENTER key Type put FLO_6MHZ bin user waveform FLO_6MHZ bin and press the ENTER key Type put LTE_5MHZ bin user waveform LTE_5MHZ bin and press the ENTER key Type put LTE_10MHZ bin user waveform LTE_10MHZ bin and press the ENTER key 10 Repeat the above steps for
16. logging collection e Support for Physical Layer throughput calculation Physical Layer throughput chart e Supports RLC Stats collection RLC Stats chart in Test Manager e Supports CQI CFI and UE Specified Aggregation Level as test case parameters e Support for real time throughput summary pane in Test Manager e Support for the MTU parameter in UE file e Supports clearing saving the eAA OTA database e Supports collection of UE category information in Test Manager e Support for time based FTP optimized FTP instead of file based e Supports the Spirent UICC card e Supports Windows 7 on the Controller PC e Supports the operating bands 3 24 25 and 26 in addition to the operating bands supported in the previous release including 1 2 4 5 7 10 12 13 14 17 and 20 1 2 4 RFPerformance LTE The following new features are included in this release of the RF Performance LTE Test Packs refer to the user manual for details e Optimizations have been implemented to reduce test time execution by 40 Test Manager includes built in intelligence to combine and execute similar tests without tearing down the LTE attach between tests e Supports the additional E UTRA operating bands given in the table below E UTRA Uplink UL operating band Downlink DL operating band Duplex Operating BS receive BS transmit Mode Band UE transmit UE receive FUL_low FUL_high FDL_low FDL_high 24 1626 5MHz 1660 5 MHz 1
17. oc pAddress enter 192 168 0 35 for the IP address as shown in Figure 2 58 8100 Mobile Device Test System LTE Product Update 45 p rLoggingtonfiq gt Logi leNarne gt Legs aap Server Legiebage Lagi leame y tLogiebugintartrest Logiebughata Si Ferver port to DL utp Lo recelve packeta gt lt B amp rverPoListenPore 540D0 lt nerverPolLiate FobistenPart gt c EZ010 port vo receive OL udp p gt CipaddressE 010510 LEB 0 3x 1iphAdsrepsE2010 gt eleaP359 TP addre ri aooresa2 CSSEVELELOLOPRPor esos perverE 0 10TRPorL 1 SeEver port t receive UL udp packeta from E2z010 gt E 0l0Listenfort gt 34001 serveri2010ListenPorta AE z gt Ls Laatrel PC IP addres 2 tpelpaddreasr1 3 168 0 Jar peliphidreaa gt l Bee E E or Ln Gnral Poe For prada po bi Eon FI ip packs ta gt pela stenbartsS40014 pelLieienrort gt lt tdpServerLoggingCoorig gt erabi Marla Language fle 666 chars 7Olbytes 17ines Lm 13 Col 27 Sel 0 0 bytes m Oranges Figure 2 58 Notepad Editing the IP Address 4 Save the document by selecting FilesSave 5 Close Notepad and Windows Explorer 2 9 Updating the Router Switch Configurations To update the router switch configurations you need to upload the configuration file and restart the device The configuration files specified are found under the 8700 LTE 4 4 0 Installer Root Router Switch Config Files folder 2 9 1 Updating the Cisco 1811 Router F
18. program connect to the router on COM1 using 9600 bps 8 data bits no parity and 1 stop bit Start the HyperTerminal application by selecting StarbAll Programs gt Accessories Communications gt HyperTerminal In the Connection Description window enter Dell in the Name field and click OK In the Connect To window select COM1 in the Connect using field and click OK 8100 Mobile Device Test System LTE Product Update 51 6 Under Port Settings select the values for each setting as shown in Figure 2 65 Port Settings Bits per second Emai Data bits E Parity None Stop bits fi Flow control Hardware Restore Defaults crea dos Figure 2 65 HyperTerminal COM Port Settings 7 Plugin the switch Wait until the switch has finished initializing 8 HyperTerminal displays the following information Unit 1 Waiting to select management unit Applying configuration please wait 64 005XXX_vXX gt 9 Type enable and press Enter 10 Your prompt should now display 64 005XXX_vXX 11 Enter the following command copy xmodem nvram startup config 12 HyperTerminal now displays MOdEC 0scceessecereeeceeeeeeee MODEM Data Type COnfig Script Destination Filename startup config Management access will be blocked for the duration of the transfer Are you sure you want to start y n 13 Press y 14 HyperTermi
19. 0 0 FastEthernet IEEE 802 3 interface s 32K bytes of non volatile configuration memory 32768K bytes of processor board System flash Read Write Press RETURN to get started Press Enter HyperTerminal displays the following prompt Spirent router Note that the prompt displayed may look different based on the installed firmware Type enable and press Enter The Router now prompts you to enter a password Type Spirent_enable The prompt now displays the following Spirent router Press Enter Enter the following command copy xmodem nvram startup config HyperTerminal now displays Destination filename startup config 8100 Mobile Device Test System LTE Product Update 47 16 17 18 19 20 21 22 23 Press Enter HyperTerminal now displays Begin the Xmodem or Xmodem 1K transfer now Use HyperTerminal to transfer the supplied configuration file by selecting TransferSend File as shown in Figure 2 60 Cisco 2600 HyperTerminal File Edit View Call Transfer Help Del 2 5 Send File Receive File Capture Text Send Text File Capture to Printer Sends a file to the remote system Figure 2 60 Send File Menu Command In the Send File window click the Browse button and select the lt 8100 LTE 4 4 0 Installer Root gt Router Switch Config Files Cisco1811 txt configuration file Send File Figure 2 61 Selec
20. 4 0 Installer Root eAirAccess E2010 Embedded PC LTE E2010 Core folder double click UpdateBootscript bat to update the E2010 boot script b The Command Prompt window displays the updated content as shown in Figure 2 54 c Before pressing any key scroll up and verify that the lines circled in Figure 2 54 are present Then press any key d Before pressing any key again scroll up and verify the circled lines were added again after the last key press message BEE Backing up old autoexecHost sh file i files copied Copying modified autoexecHost sh 1 filets copied t Host sh contents ddrgdramCf g xc 3000000 HEHU I ROMMERT VAR puteny lt AT4 SHARED_ROOT home vxtser shared gt putenv lt AT4_ HWSET CELL_A gt LD_LIBRARY_PATH putenu AT4_ WORKS PACE_ROOT home uxUser works pace gt putenv lt LD_ 0_CONF home uxUser works pace etc ld_Host so0 conf gt puteny lt BUILD CONFI G PPC32UK68RD gt BOOT_ COMMAND putenv AT4_RIO_ REPOSITORY hone vxUser workspace VOB_L1i LTE_Li_SU FpgaDbevDriver Workbench 2 PPC329gnu_SMP_MC AT4FpgaDdevDriver HonDebug home vuxlser workspace W OB SWCore CoreR OFramevork_MC RIODrvRepositoryHost gt putenv lt BUILD_INFO PPC32UR 68RD puten lt 4 AT4_RIO_MULTICELL E gt putenv lt AT4_ RIGO_HOST_IP 16 168 6 2 5 putenuc AT4_ RIO _AGENT_IP 19 168 9 4 putenv AT4_ RIO _SYNCHRONIZATION_PORT 2922 taskPriorit yet taskNameTo
21. 44 8100 Mobile Device Test System LTE Product Update SB Session 1 10 168 0 2 BEE gt getFWersioni FpgabewDLATON FpogaDeywDLATON Installed Version 02040100 value 335165352 Ox2040100 gt getFWUVersion FpqabevDLFRE value 50397696 Ox3010200 gt getFWersion FpgaDeywWUL value 262145 Ox40001 gt getFWwersion FpqgaDeywRa FpoaDeyvRa Installed Version 01000102 value 16777474 Ox1000102 Figure 2 56 FPGA Firmware Versions 4 Close the window 2 8 4 8 Edit UdpServerLoggingConfig xml 1 Under My Computer navigate to U VOB_SW LTE_SW_SU WinAgents UdpServer as shown in Figure 2 57 fi UdpServer File Edit View Favorites Tools Help ae Gra T x P Search E Folders Fi Address 5 U VOB_SW LTE_SW_SU WinAgents UdpServer vi 5 Go Name i Type Date Modified File and Folder Tasks A Logs File Folder 5 31 2011 4 34 PM udpclient exe Application 8 27 2010 3 48 PM udpserver exe Application 8 27 2010 3 48 PM Publish this folder to the UdpServerLoggi I XML Document 5 31 2011 4 33 PM Web UdpServerLoggingConfig xm cumen 31 E E Share this folder QJ Make a new folder Other Places Details Ei U voB_SW LTE_s E Document WordPad fae UdpServer jx Us Ls EDK 9 56 AM Figure 2 57 UdpServer Folder 2 Right click the UdpServerLoggingConfig xml file and select Edit with Notepad from the menu 3 Inthe Notepad window under the line marked lt
22. 525 MHz 1559 MHz FDD O ca 1850 MHz 1915 MHz 1930 MHz 1995 MHz cm 814 MHz 849 MHz 859 MHz 894MHz 4 8100 Mobile Device Test System LTE Product Update e Supports the E UTRA channel bandwidths given in the table below E UTRA Band Channel Bandwidth E UTRA Band 1 4 MHz 3 MHz 5 MHz 10 MHz 15 MHz 20 MHz 24 Yes Yes Yes Yes Yes Yes 25 Yes Yes Yes Yes Yes Yes 26 Yes Yes Yes Yes Yes Yes e SVLTE test cases have been updated to comply with the Verizon Wireless Compliance Test Plan Conformance and Performance for Simultaneous Circuit Switched Voice and Packet Data Capable LTE Multi Mode Devices version 4 0 issued June 2011 e The following SVLTE test cases as specified in the Verizon Wireless Compliance Test Plan Conformance and Performance for Simultaneous Circuit Switched Voice and Packet Data Capable LTE Multi Mode Devices version 4 0 issued June 2011 are now supported Test Test Name Number Test Pack Additional Required Instruments 2 1 LTE Performance in the Presence of a 1xRTT Voice Call Test LTE RF Output Power Back off Conformance TP RF SVLTE TP1 Agilent 8960 e The following test cases as specified in the Verizon Wireless Compliance Test Plan LTE 3GPP Band 13 Supplementary RF Conformance version 10 0 issued June 2011 are now supported Test Number Test Name Test Pack Additional Required Instruments
23. C message shown in Figure 2 47 displays Click OK HW SET MC A Please TURN all the boards in the E2010 ON for MultiCell Setup Figure 2 47 HW SET MC Message Turn Boards On 10 The HW SET MCwindow shown in Figure 2 48 displays click OK HW SET MC In case of there are boards Off open the E2010 and push all the pins down Finally press OK Figure 2 48 HW SET MC Message If Boards Are Off 11 A Command window displays verifying the MCH Configuration Parameters as shown in Figure 2 49 8100 Mobile Device Test System LTE Product Update 39 n BGE El DISCOVERING HW SET Connecting to MCH for checking E2618 HW Configuration Telnet Connection Open to 10 168 0 3 Send Command gq Send Command gq Send Command show_fru MCH NMGH GM memei NAT MGCH MGMG ANGI HWG_883 At4wirel AMC2 HWG_663 At4wirel ANC HWG_683 At4wirel AMC4 HWG_863 At4wirel AMOS HWG_863 At4wirel ANCE HWG_883 At4wirel AMC B3 AM4100 ANCES HWG_663 At4wirel ANC HWG_663 At4wirel ANCI2 Rc AN41 68 Schroff uTGCA Cu Schroff 120 PFIM MCGH Clock MCH SRIO Send Command i filets copied Checking the found boards Waiting for preparing the Fulpgrade files CHECKING MCH CONFIGURATION Connecting to MCH for checking MCH Configuration Telnet Connection Open to 109 168 0 3 Send Command gq Send Command gq Send Command mch mch INFO MCH configuration CFG V2 5 for V2 6 Final 68 54 56 Aug 21 20095 ok MCH global p
24. Framework 1 Uninstall any previous versions of Logging Framework components a Stop the Logging Framework by selecting Start All Programs AT4 Wireless gt Logging Framework Runtime gt Stop Logging Framework b An nformationwindow displays verifying that Logging Framework has been stopped as shown in Figure 2 30 Information Lui x 1 Logging Framework stopped Figure 2 30 Logging Framework Information Window c From the Control Panel select Add or Remove Programs and remove the AT4 Wireless Logging Generator COM Interface d Uninstall LogAgent by selecting Start All Programs gt AT4 Wireless gt Logging Agent gt Uninstall 2 Install Logging Framework a Navigate to the 8100 LTE 4 4 0 Installer Root eAirAccess E2010 Embedded PC Logging Framework folder b Execute Logging Framework Runtime Setup Embedded PC exe and accept the defaults 2 8 2 Installing Layer 3 Components 1 Uninstall any previous versions of the Layer 3 Components a Stop the Layer 3 Components by navigating to C Program Files Spirent Communications eAirAccess L3 and double clicking the killeNBEmu bat script b From the Control Panel select Add or Remove Programs and remove the L3 Component Installer 2 Install the Layer 3 Components a Navigate to the 8100 LTE 4 4 0 Installer Roob eAirAccess E2010 Embedded PC Layer 3 Components folder b Execute Layer3Components and accept the default settings 30 8100 Mobile Device Test Syste
25. SPIRENT 8100 Mobile Device Test System Radio Access LTE Product Update o y 6 s W e w gt amp _ __ r _ m b wxwpr ll Spirent 541 Industrial Way West Eatontown NJ 07724 USA Email sales spirent com Web http www spirent com AMERICAS 1 800 SPIRENT 1 818 676 2683 sales spirent com EUROPE AND THE MIDDLE EAST 44 0 1293 767979 emeainfo spirent com ASIA AND THE PACIFIC 86 10 8518 2539 e salesasia spirent com Page Part Number 71 006692 Version AO Copyright 2012 Spirent All Rights Reserved All of the company names and or brand names and or product names referred to in this document in particular the name Spirent and its logo device are either registered trademarks or trademarks of Spirent plc and its subsidiaries pending registration in accordance with relevant national laws All other registered trademarks or trademarks are the property of their respective owners The information contained in this document is subject to change without notice and does not represent a commitment on the part of Spirent The information in this document is believed to be accurate and reliable however Spirent assumes no responsibility or liability for any errors or inaccuracies that may appear in the document Table of Contents I MTFOQUCTION lt 3 ssccscccasccnasaseanaaeadeancdeanedeanedeanadeansdseonsesonsesonsesonsesonsesessaseess 1 Lola OVVU aisar oire reina na 1 LZ INCWFESLUFE Sare
26. Saved Are you sure you want to reload the stack y n 23 Press y 24 HyperTerminal displays Reloading all switches 25 The router now restarts 26 Press Enter and verify the prompt displays the configuration file part number with the correct revision 64_005467_vXX 27 The upgrade is now complete 2 10 Installing the Agilent ESG Waveform Files These procedures only apply to systems equipped to execute the RF Performance LTE test cases 2 10 1 Overview Some of the receiver tests make use of ESGs to generate interference signals The files are packaged and installed in the C Program Files Spirent Communications Test Manager Modules RF LTE Interference Waveform Files directory You must upload these waveform files onto the ESG before conducting tests 2 10 2 Setting Up the LAN Interface Configuration for the ESG The ESG1 is the unit connected to P15 of the SR8048 TCU To assign a hostname and IP address to the signal generator follow the instructions given below Note that the hostname and IP address are persistent states they are not affected by an instrument preset or power cycle 54 8100 Mobile Device Test System LTE Product Update 2 10 2 1 Manual Configuration L 2 Press Utility GPIB RS 232 LAN gt LAN Setup Press Hostname NOTE The Hostname soft key is only available when LAN Config Manual DHCP is set to Manual Use the labeled text soft keys and orthe numeric
27. TTY icon di on the E2010 desktop 2 In the PuTTY Configuration window load GPP A as shown in Figure 2 51 Click Open to continue is PuTTY Configuration im Logging 2 destination you want to connect to Terminal i i Keyboard Bel w 600 i Features E Window Ohm Tenet O Rlogin OSSH Serial fee arance a dn Load save or delete a stored session Translation Saved Sessions Crus O Never Only on clean exit Figure 2 51 PuTTY Configuration Window 3 Click ApplicationLauncher on the Windows system tray as shown in Figure 2 52 Www at4Wireless Com DUM be 11 29 AM Figure 2 52 Application Launcher Icon 4 Select Reboot SU to reboot the E2010 5 This will take several minutes Monitor the Pu77Ywindow closely During the reboot process the NetBootLoader version displays on the Pu77Y window for about fifteen 15 seconds as shown in Figure 2 53 Make a note of the first three digits of the Version of running NetBootLoader In the example given in Figure 2 53 it is 110 42 8100 Mobile Device Test System LTE Product Update t Wait Time LED blinks oot time expired probing all e file nb10 cfg Figure 2 53 PuTTY Window NetBootLoader Version 6 Perform the following steps only if the first three digits of the NetBootLoader version are 110 Otherwise skip the steps below a Underthe lt 8100 LTE 4
28. Windows XP Client Laptop e Windows Server 2003 Applications Server To disable Microsoft Update 1 Select Start gt Control PanebPerformance and Maintenance System The System Properties window displays 2 Under the Automatic Updates tab select the Turn off Automatic Updates option as shown in Figure 3 4 System Properties General O Computer Name Hardware Advanced lja system Restore ai Automatic Updates iL E _ Remote Help protect your FE Windows can regulary check for important updates and install them for you Turning on Automatic Updates may automatically update Windows Update software first before any other updates How does Automatic Updates work O Automatic recommended Automatically download recommended updates for my computer and install them iI ih Download updates for me but let me choose when to install them O Notify me but don t automatically download or install them G Lum off Automatic Updates four computer will be more vulnerable unless you install updates regularly Install updates from the Windows Update Web site Figure 3 4 System Properties Window Automatic Updates Tab 3 Click OK to save the changes and exit the window 60 8100 Mobile Device Test System LTE Product Update 3 4 2 Windows 7 Perform the following steps on each of the following PCs included in your system di 4 Windows 7
29. Wireless LTE Product Selection window select S1 AP and click OK as shown in Figure 2 34 8100 Mobile Device Test System LTE Product Update 33 J Default AT4 Wireless LTE Product Selection e the default E2010 software E2010 Calibration Mode T4010 LTE RF Conformance Tester RCT T4020 LTE RRM Conformance Tester RRM T4110 LTE Protocol Conformance Tester PCT 2331106 Mobile Test Application MTA Figure 2 34 Default AT4 Product Selection Window 5 Inthe SU Managerx x x x Uninstallwindow click Yes 6 In SU Manager Uninstall Wizard Welcome window shown in Figure 2 35 click Next x SU_ Manager 2 6 0 15 Uninstall Welcome to the SU_Manager 2 6 0 15 Uninstall Wizard This wizard will guide you through the uninstallation of SU_Manager 2 6 0 15 Before starting the uninstallation make sure SU_Manager 2 6 0 15 is not running Click Next to continue Figure 2 35 SU_Manager Uninstall Wizard Welcome 7 Inthe Uninstall SU Managerwindow click Next as shown in Figure 2 36 34 8100 Mobile Device Test System LTE Product Update SU Manager 2 6 0 15 Uninstall Uninstall SU_Manager 2 6 0 15 Remove SU_Manager 2 6 0 15 from your computer SU_Manager will be uninstalled from your system Click Cancel to abort the uninstallation process 474 wireless C Program Files AT4 Wireless SU_Manager_A Figure 2 36 Uninstalling SU_Manager 8 The Choose Components window displa
30. arameter remote interfaces Management interface at GbE port RMCP access telnet access WEB access IP address source Mgmt hoard configuration IP address source GbE board configuration RMGCP session activity timeout minutes min RMCP session activity timeout seconds 20 sec default fan level 30 percent MCH configuration flags Enable backward compatibility V2 4 no enabled enabled enabled enabled Shelf manager parameter ShM configuration flags allow shelf FRU invalid temperature management emergency 4 down on vitica ves enabled CI Figure 2 49 MCH Configuration Parameter Verification 12 The upgrade process will now continue for several minutes 13 When the upgrade procedure is completed the window shown in Figure 2 50 displays Verify that the FPGAs versions match those circled in Figure 2 50 and that the E2010 has been successfully upgraded If it is a 2 Cell unit there will also be verification that Cell B has been successfully upgraded Press the Space Bar to continue 40 8100 Mobile Device Test System LTE Product Update 5 BOE INFO reboot _MultiCell on going WaitCGonnection lt timeOut 890900 validStates 09 GetConnectedStateC3 1 GetConnectedStatet A WaitConnection timeOut 450968 validStates H gt pet M WaitConnection t imeOut 3009090 validStates 1 3 gt GetConnectedStatet gt 1 WaitConnectionttimedut 236HHHH validStates 1 3 3 pret i INFO Cells Rec
31. ccess CONfIQUIATION ccccessccccnssscccnscscccesseceees 19 Il 8100 Mobile Device Test System LTE Product Update 2 9 2 6 2 2 8 2 9 2 10 2 11 2 12 2 4 7 Completing AirAccess C2K Installation vvrrrrrrrrrrrrrrrrirericeeni 19 2 4 8 Correct Calibration Files Access Permissions Windows 7 21 Upgrading the Client Laptop ccsccsscssccsscescsccsscscescesscescesceecs 24 2 5 1 Updating Spirent AT Control cccsccccsecccsscccsccccnscccescccsscecescecescess 24 2 5 2 Updating Spirent Data CHEN oxisavecesavesedsendisseodidasastedcavsacteveceeesaseseaers 24 Upgrading the Application Server ccssccsscssccsccsscsccscesscescessceecs 25 2 6 1 Updating Spirent Data Client ssscccssscccssscccnsscccsscccesscceesscceeesces 25 2 6 2 Updating Xlight IPv6 FTP Server Configuration rr 25 Updating the EPC SerVe r seesseeesessesseseseoseercsesecseoreseosscseosceeeseseoseesee 27 POCA UIMG TEE 20105 arena E rat 29 2 8 1 Installing LOGGING Framework cescccesecccnscccsccccnscccescecsscecescesescess 29 2 8 2 Installing Layer 3 COMPONENES cccesecconsccesccccsscccsccccsscccesceeescees 29 2 8 3 Installing E2010 Managert hrscscseccdssececsawovseccestinssseseveccecsenneeceeteanaaces 30 2 8 4 Installing E2010 Core Software ccesecconsccesccccnscccescccsscecescesescess 30 Updating the Router Switch Configurat
32. component indicates which components have been detected as installed on the system 12 8100 Mobile Device Test System LTE Product Update The following list describes the different icons used in the Global Installer x The software is not installed A different version of the software is already installed 4 The software is selected for install also displays on the Install List S The correct version of the software is already installed To install software components using the Global Installer application 1 To mark a software component for installation select the component The icon changes to a green checkmark and the component is added to the Install List 2 Add additional components as necessary You can add components from different tabs prior to starting the installation 3 Click the Installation toolbar button F to begin the installation The progress of the install displays on the left pane When complete a Summary window displays 8100 Mobile Device Test System LTE Product Update 13 2 4 Upgrading the Controller PC Connect the device containing the unzipped installer to the Controller PC 2 4 1 Preparing For The Update i Ensure that the following applications are not running g ho a n o Test Stand Sequence Editor eAirAccess AirAccess C2K AirAccess WCDMA HS Intrig IDM Universal DM V2 Spirent Data Client 2 Save the existing security passwords a b C
33. e Scan For threats Edit with Notepad Open with Send To ut Figure 2 1 Extract All Files 5 Use the Extraction Wizard to extract the files to a known location as shown in Figure 2 2 Select a Destination Files inside the ZIP archive will be extracted to the location you choose Select a folder to extract files to Files will be extracted to this directory Browse Password Extracting Figure 2 2 Using the Extraction Wizard 8100 Mobile Device Test System LTE Product Update 11 2 3 Using the Global Installer Application This section provides information on how to use the Global Installer This application allows you to update different computers in the system using a convenient user interface To run the Global Installer application 1 Navigate to the lt 8100 LTE 4 4 0 Installer Root folder 2 Run the setup exe file The 8100 Mobile Device Test System nstallerwindow displays as shown in Figure 2 3 Install List SPIRENT GO Air ccess WCDMA HS v4 31 002 installed GY E2010S Driver v2 5 15 installed g e ir ccess v1 30 004 installed Y Spirent Data Clientv1 11 141 installed vA TCU Driver v1 0 13 installed J Universal DM V2 v4 7 1 installed Figure 2 3 8100 Mobile Device Test System Installer Window The Global Installer application organizes the software components into separate tabs Shown in Figure 2 3 The icon next to each
34. encountered if you do not update every module If this is occurs uninstall and then reinstall all of the modules Platform Files created using previous releases are not automatically upgraded correctly in this release Delete all previously created Platform Files and generate new Platform Files prior to executing any test cases Refer to Section 0 for details Bandwidths 1 4M 3M 15M and 20MHz are enabled but have not been fully tested due to UE availability Band classes 1 2 3 5 7 10 12 14 20 24 25 26 and 27 are enabled but have not been fully tested due to UE availability 1 4 1 CDMA LTE Mobility The following issues are applicable to the CDMA LTE Mobility Test Packs The SIB 8 field specifying the CDMA time is not populated correctly UEs that rely on this field to perform measurements of the CDMA systems during scheduled LTE measurement gaps may not perform correctly during tests requiring this capability In the IOT test cases that test the LTE eHRPD handover by using FTP to perform transfer verification if the UE takes more than one minute to finish the handover the existing FTP transfer is terminated A new FIP transfer is then used to verify FTP transmission after the handover 8100 Mobile Device Test System LTE Product Update 7 1 4 2 Data Retry LTE There are no known issues specifically applicable to the Data Retry LTE Test Packs 1 4 3 Data Throughput LTE The following issues are a
35. er second Emai Data bits E Parity None Stop bits fi Flow control Hardware Restore Defaults ree oso Figure 2 62 HyperTerminal COM Port Settings 7 Power on the router Wait until the router has finished initializing 8100 Mobile Device Test System LTE Product Update 49 8 HyperTerminal should display the following information cisco 2610XM MPC860P processor revision 0x400 with 124928K 6144K bytes of memory Processor board ID JMX0845L1FA 879732514 M860 processor part number 5 mask 2 Bridging software X 25 software Version 3 0 0 17 FastEthernet IEEE 802 3 interface s 32K bytes of non volatile configuration memory 32768K bytes of processor board System flash Read Write Press RETURN to get started 9 Press Enter HyperTerminal displays the following Spirent router Note that the prompt may look different based on the installed firmware 10 Type enable and press Enter 11 The Router now prompts you for a password Enter Spirent_enable 12 Your prompt should now look like this Spirent router 13 Enter the following command copy xmodem nvram startup config 14 HyperTerminal now displays Destination filename startup config 15 Press Enter HyperTerminal now displays Begin the Xmodem or Xmodem 1K transfer now 16 Use HyperTerminal to transfer the supplied configuration file by selecting TransferSend File as shown in Figure 2 63
36. ers a Allow CREATOR OWNER Special Ci ProgramDatal Subfolders and files only Allow Users WIK AVYTIRVSD Read amp execute C ProgramDatal This Folder subfolders a Allow Users WIN AYWTIR7SD Special C ProgramDatal This Folder and subfolders te tenore fe Include inheritable permissions from this object s parent I Replace all child object permissions with inheritable permissions from this object cane ao Figure 2 20 Advanced Security Settings Window 9 Verify that you have a new permission entry for Users that allows Full Control as shown in Figure 2 21 Click Apply and OK save the settings and exit the window 24 8100 Mobile Device Test System LTE Product Update N Advanced Security Settings for Development Library Services Permissions To view or edit details for a permission entry select the entry and then click Edit Object name C ProgramDatal Spirent Communications Development Library Services Permission entries Users WIN AVVTIRTSD Full control Allow SYSTEM Full control C ProgramData This folder subholders a Allow Administrators WIN AY Full control C ProgramDatal This folder subfolders a Allow CREATOR OWNER Special C ProgramDatal Subfolders and files only Allow Users WIN AYVTIR75D Read amp execute CilProgramDatal This folder subfolders a Allow Users WIN AWYTIR75SD Special C ProgramDatal This folder and subfolders Figure 2 21 Verifying Pe
37. external filter between the spectrum analyzer and the SR8068 TCU These external filters will be automatically shipped to the existing customers The occasional throughput failures seen with Receiver Sensitivity and Receiver Blocking tests due to incorrect calculation of FER due to a timing issue have been addressed 6 8100 Mobile Device Test System LTE Product Update 1 3 5 UMTS LTE Mobility No maintenance updates have been added to the UMTS LTE Mobility Test Packs 1 4 Known Issues The following issues are applicable to all Test Packs on the 8100 Mobile Device Test System v4 4 0 There is an issue with removing the test data cards and test phones from Dell Latitude E6500 E6510 E6520 Client Laptops connected through the PCMCIA slot or USB If the client laptop model is a Dell Latitude E6500 E6510 Refer to Section 3 1 for details There is a potential conflict that can occur if the device installs a Network Interface driver Refer to Section 3 2 for details Attempting to abort calibration causes Test Manager to freeze Refer to Section 3 3 for details The log file format of the OTA messages has changed therefore OTA messages collected with v4 3 1 cannot be decoded for viewing Installation of Microsoft Security Essentials enables Microsoft Update Microsoft Update must be disabled This applies to the Controller PC Client Laptop and the Applications Server Refer to Section 0 for details Errors may be
38. fer to Section 2 3 on page 11 1 Start the Global Installer application 2 Ifthe correct version of Spirent Data Client is not installed select the Spirent Data Client component 3 Click the Installation toolbar button 3 to begin the installation 4 Exit the Global Installer application 2 6 2 Updating Xlight IPv6 FTP Server Configuration 1 Double click the Xlight FTP Server icon from the desktop as shown in Figure 2 22 light FTP Server Figure 2 22 Xlight IPv6 FTP Icon 2 The Duplicated Process window shown in Figure 2 23 displays Click Yes to proceed Duplicated Process Another Xlight program is already running do you want to show its main window Figure 2 23 Duplicated Process Warning Window 26 8100 Mobile Device Test System LTE Product Update 3 Select the fd00 0 20 1 4 IPv6 server and click the Modify Virtual Server Configuration button as shown in Figure 2 24 Admin Console Xlight FTP Server System Service marea Modify virtual Server Configuration fd00 0 20 1 4 21 Running 0 4 237 GB 1 562 GB 396 IPy6 FTP S 19 Kbps Unit 1 Kbps Send 0 0 KB s Recv 0 0 KB s Downloaded 4 237 GB Uploaded 1 563 GB Online Users 0 Figure 2 24 Modify Virtual Server Configuration Button 4 Underthe Genera tab change the Maximum idle time parameter to 120 and select the Enable the anti idle scheme option as shown in Figure 2 25 FTP fd00 0 20 1
39. he SR3600 exe file 3 In the Upgrade window select Instrument gt Install Firmware Update as shown in Figure 2 27 SR3600 192 168 0 92 Version 9 5 0 45 5 State READY OK Instrument Connect to Instrument O Connected to muster TTL LTT Install Firmware Update a Reset Instrument Shut Down Instrument SPIRENT Communications Figure 2 27 Opening the Firmware Update 28 8100 Mobile Device Test System LTE Product Update 4 Inthe Open window navigate to C Program Files Spirent Communications eAirAccess 5 Select the tsu file and click the Open button as shown in Figure 2 28 9 Test Configuration Files coast 9 5 0 45 5 tsu File name coast_9 5 0 45 5 teu Su Files of type Open as read only Figure 2 28 Opening the tsu File 6 Wait for the update to complete this will take several minutes as shown in Figure 2 29 SR3600 192 168 0 92 Version 9 5 0 45 5 State READY Sele Instrument Connectedto erula PTT TT PPP Update successfully sent BE REND INNO i seine PT TTT LL LLL S PIRENT Update completed OLR Figure 2 29 Update Status 7 Close the SR3600 tool 8100 Mobile Device Test System LTE Product Update 29 2 8 Updating the E2010S Connect the device containing the unzipped installer to the E2010S 2 8 1 Installing Logging
40. ied 12 19 2011 11 01 AM Date created 12 20 2011 11 24 AM TM Shortcut Size 2 19 KB Offline availability Mot available Figure 2 9 PUG Script Files 6 Copy the Test Manager shortcut and move it to the Desktop A Copy File window displays as shown in Figure 2 10 Select Copy and Replace 18 8100 Mobile Device Test System LTE Product Update Copy File x There is already a file with the same name in this location Click the file you want to keep Copy and Replace Replace the file in the destination folder with the file you are copying JI a Test Manager lnk Test Manager 10 7 5 40 mdt 8100 MDT System Staging v4 4 0 TM December FM 8100 MDT System RA LTE v4 4 0 A7 Test ManageriPUG Script Files Size 2 19 EB Dake modified 12 19 2011 11 01 4M newer Don t copy No files will be changed Leave this file in the destination Folder Test Manager lnk Test Manager C UsersiSpirenti Desktop T Size 2 20 KB larger Date modified 12 16 2011 10 14 4M Copy but keep both files The file you are copying will be renamed Test Manager 3 Ink Figure 2 10 Copy and Replace Confirmation Window 7 The Test Manger application will now run with the highest administrative privileges when this icon is selected 2 4 5 2 Updating Test Manager Passwords and User Files 1 Start Test Manager and select Help About Passwords 2 Select and open the passwords csv file exported in Section 2 4 1 on page 13
41. indows 7 is not supported on the Controller PC LTE RF test cases will not run properly if the UE is permitted to acquire an IP address when it is connected to the Controller PC for UE automation In this case the internet protocol feature of the UE network interface must be disabled Refer to Section 3 6 for details 1 4 5 UMTS LTE Mobility The following issues are applicable to the UMTS LTE Mobility Test Packs IOT was performed with the only device available Sierra Wireless U313 data card Interoperability with other devices is not known 8 8100 Mobile Device Test System LTE Product Update e Anewcomponent from the Global Installer DVD UE AT Interface for CS8 must be installed when upgrading the UMTS LTE Mobility module to this release You can select this component for installation under the nstruments tab as shown in Figure 1 1 I i 8100 Mobile Device Test System UE aC i I SE A SPIRENT Communications X Spirent Data Clentv1 12 213 not installed x Spirent WCEHAPI v3 51 034 not installed Qd 5R5500 Testkitv3 51 002 not installed TCU2 Driver v1 0 16 not installed X UE AT Interface for CSE v1 5 60 not installed Qd Universal DM V2 v4 7 1 not installed Figure 1 1 Global Installer Instruments Tab e Note that the Global Installer software may not correctly detect that the VE AT Interface for CS8 SWis installed This is due to a naming convention mismatch If you enc
42. ing Framework folder Execute Logging Framework Runtime Setup exe and accept the defaults Execute AT4 Wireless Dissectors Setup exe file and accept the defaults 16 8100 Mobile Device Test System LTE Product Update 2 4 5 Completing Test Manager Configuration 2 4 5 1 Configuring Test Manager to Run as Administrator Windows 7 1 Start the Windows 7 Task Scheduler enter task in the Run Application window as shown in Figure 2 6 Programs 1 Task Scheduler Control Panel 18 i Taskbar and Start Menu Perform recommended maintenance tasks automatically 1 View running processes with Task Manager LA Auto hide the taskbar LA Customize the taskbar i Group similar windows on the taskbar LA Lock or unlock the taskbar i Turn toolbars on the taskbar on or off customize icons on the taskbar Show or hide inactive icons on the taskbar Documents 2 _ Locking c _ AsyncIO c See more results task Shut down gt Figure 2 6 Starting Task Scheduler 2 Select the Import Task option from Actions panel as shown in Figure 2 7 Task Scheduler ES a x File Action View Help e AmE Task Scheduler Local Tri Tear D CO201DFF Ready Task Scheduler Library 9 JavaUpdateS Ready Sbeststandtask Ready D imtask Running Create Task Bi Create Basic Task Import Task Display All Running T General Triggers Act 4 P Enable All Tas
43. install over a component to see its description Space required 0 0KB 474 wireless Figure 2 42 CAL_AGENT Uninstall Wizard Choose Components 4 Inthe Choose Components window shown in Figure 2 42 click Uninstall 5 Inthe Completing the Uninstall Wizard window shown in Figure 2 43 click Finish 8100 Mobile Device Test System LTE Product Update 37 x CAL AGENT Calibration Mode 0 3 2 10 Uninstall Completing the CAL AGENT Calibration Mode 0 3 2 10 Uninstall CAL_AGENT Calibration Mode 0 3 2 10 has been uninstalled from your computer Click Finish to close this wizard Figure 2 43 Completing the Uninstall Wizard 6 Amessage displays verifying that CAL_AGENT successfully removed as shown in Figure 2 44 Click OK x CAL AGENT Calibration Mode 0 3 2 10 Uninstall Figure 2 44 Software Successfully Removed Message 7 Inthe Check Calibration Data window shown in Figure 2 45 click OK Check Calibration Data A Proper calibration data for 0 7dB have been detected Figure 2 45 Check Calibration Data Window 8 Inthe L7E 2010 Signaling Unit Software Installer Setup window shown in Figure 2 46 click Yes LTE E2010 Signalling Unit Software Installer Setup Do you want to execute the E2010 Software Upgrade Procedure It could take up to 15 mins Figure 2 46 Execute the Upgrade Procedure Window 38 8100 Mobile Device Test System LTE Product Update 9 The HW SET M
44. ions seessssssssssessssecssscsseceses 45 2 9 1 Updating the Cisco 1811 Router ccssecccssscccnsscccssscccsscceesscceeesces 45 2 9 2 Updating the Cisco 2600 ROUET ccssscccsssccensscccsssccesscccesscceeesces 48 2 9 3 Updating the Dell 6248 SWITCH cccssscccssscccnsecccsscccesscceesscceeesces 50 Installing the Agilent ESG Waveform Files secsssescsssssscescecesees 53 2401 ORI 53 2 10 2 Setting Up the LAN Interface Configuration for the ESG 53 2 10 3 Downloading Waveform Files to the ESG ccccssccsssccsssccesceeescees 54 Configuring the Agilent EXA MXA Spectrum Analyzer 0 0s 55 Installing New System Cables ccccsscssccsscsscescesscscesccsscesceesceecs 56 21 LENO CADIS iniettati 56 2 422 SVNCHONIZGHOM CAD Cerrina piinininae 56 8100 Mobile Device Test System LTE Product Update iii 3 Known Issues Details ss cccscccssccasccssccssceccsusawesusssunssvassunsseasessasssusesescsees 57 3 1 Dell Latitude E6500 E6510 E6520 Client Laptop Issue 57 3 2 UE Drivers that Install a Network Interface cccccscsssscsscsceceseeees 57 3 3 Unable to Abort Calibration cccccsccsscsscescsscescsscesccscesccsceeceeces 58 3 4 Disabling Microsoft Update ccsscssccsccssccsccsccssccecesscescesccesceecs 59 3 4 1 Windows XP and Windows Server 2003 c sceesceeccnsccnsccnccceccsceesees 59
45. ions 6 Under Full Control select Allow as shown in Figure 2 19 8100 Mobile Device Test System LTE Product Update 23 Object TIR7SDOGiLsers Users WIN AY Name Apply to This folder subfolders and files Permissions allo Full control Traverse folder f execute file List folder read data Read attributes Read extended attributes Create files write data Create folders append data Write attributes Write extended attributes Delete subfolders and files Delete igigigigigigigicisis Apply these permissions to objects and or Clear All a containers within this container only cei Figure 2 19 Selecting Permission Options 7 Click OK 8 Inthe Advanced Security Settings window select the Replace all child object permissions with inheritable permission from this object option as shown in Figure 2 20 This option applies the change to all subfolders and files N Advanced Security Settings for Development Library Services i Permissions To view or edit details for a permission entry select the entry and then click Edit Object name C ProgramData Spirent Communications Development Library Services Permission entries Jes lia Pete etade Amblt _ _ Users WIN 4YYTIR7SD Full control not ee This folder subfolders a SYSTEM Full contral C ProgramDatal This Folder subfolders a Allos Administrators WIK AY Full control C ProgramDatal This folder subfold
46. ks History Mame lavallpdate 3 New Folder Location View Author Java al Refresh Description In QEMUpd H Help Create a task From the selected task file Figure 2 7 Task Scheduler Window 8100 Mobile Device Test System LTE Product Update 17 3 Navigate to the 8100 LTE 4 4 0 Installer Root Test Manager PUG Script Files folder select the tmtask xml file and click Open as shown in Figure 2 8 Organize New Folder a H 7 pi Downloads a Mame Date modified Type i Recent Places tmtask xml 12 19 2011 11 06 AM KML Document Libraries i TL Documents al Music Pictures E videos Be Homegroup ie Computer os ic cow Restore_image D 4 File name oi files xml cc Figure 2 8 Opening the xml File 4 A New Jask window displays with the required parameters already populated Click OK and close the Task Scheduler 5 Replace the existing Test Manager Desktop Shortcut by navigating to the 8700 LTE 4 4 0 Installer Root Test Manager PUG Script Files folder as shown in Figure 2 9 i PUG Script Files Test Manager PUG Script Files Organize Open Burn New folder oF cil ir Favarit s Mame Date modified Type BE Desktop E Test Manager 12 19 2011 11 01 AM Shortcut l Downloads tmtask xml 12 19 2011 11 06 AM XML Document Recent Places Libraries ls Documents 4 i Test Manager Date modif
47. lId tLoglask gt 26H gt edrClear Press any key to continue Figure 2 54 Command Window Updated Boot Script Information 8100 Mobile Device Test System LTE Product Update 43 2 8 4 6 Regenerating Cal Files L 2 Press the front power button on the E2010S to shut down the unit Turn off the power supply switch on the rear of the unit Wait a few seconds and turn the power supply switch back on On the front of the E2010S press the power button to boot up the unit Right click the Cal Agent icon in the Window System Tray and select Generate as shown in Figure 2 55 If the Cal Agent Icon is not present select Start All Programs AT4 WIRELESS gt CAL AGENT gt CAL AGENT Generate Integrity Reports Exit Figure 2 55 CAL Agent Icon Generating the cal files takes about 5 10 minutes to complete To verify that the files have been generated click the Cal Agent icon The Generate menu item should now have a check mark If it is disabled the process is not complete Right click the SU Manager icon from the System Tray and select Restart Service Wait until the icon stops blinking 2 8 4 7 Verifying E2010S Firmware Version 1 Open Window Explorer and navigate to C AT4wireless LTE_E2010 SW_LTE_SU_R1_2_5_1_6 FW Run the GetFWVersion script by double clicking the GetFWVersions at4 file Verify that the firmware versions for the four FPGA match the ones shown in Figure 2 56
48. laptop To avoid this conflict we recommend that you disable the Network Interface if the TestDrive Data Connection Dial Up Modem is the targeted interface for the session as shown in the Figures below If the Network Interface is not disabled data call setups could fail with a RasDial exception 58 8100 Mobile Device Test System LTE Product Update Fie Ci Wee Fiera Tasso davero Hep fp fa Peters ssf se Dara retor 4 ee p a Pee or ual alli pat tek ife Charge Vici Frera i ui Cinti dei Pl coli 4 Bipa Tai darti W nare Pa comecton ki _ CA Testine Data Connector g Gra a rara er commartad 3 St up a hee el Ci pany rican Gara Got fatte deg Cect edemi Aral LAR se High Speed Internet arena 3 ima Met Dr Sor Ek La Mi el ire T L h Figure 3 3 Network Connections Window Successfully Disabled Network Interface 3 3 Unable to Abort Calibration In the Calibration Wizard clicking the Abort button freezes TestManager in a non working state You must re launch TestManager to continue 8100 Mobile Device Test System LTE Product Update 59 3 4 Disabling Microsoft Update After installing Microsoft Security Essentials Microsoft Update is enabled by default Microsoft Update must be disabled on 8100 systems 3 4 1 Windows XP and Windows Server 2003 Perform the following steps on each of the following PCs included in your system e Windows XP Controller PC e
49. m LTE Product Update 2 8 3 Installing E2010 Manager 1 2 Uninstall any previous versions of the E2010Manager a Open Task Manager by right clicking the clock on the right side of the System Tray and selecting Task Manager from the menu Under the Processestab select E2010Manager exe and click the End Process button From the Control Panel select Add or Remove Programs and remove E2010Manager Install E2010Manager a Navigate to the 8700 LTE 4 4 0 Installer Roob eAirAccess E 2010 Embedded PC E2010Manager folder Execute the setup exe file and accept the defaults After installing the E2010Manager execute a hard reboot of the E2010 by pressing the power button on the front of the E2010S When the box reboots E2010Manager should run automatically Verify this by opening Task Manager and confirming the E2010Manager exe process Is running If E2010Manager is not running start it manually by running the exe file found under C Program Files Spirent Communications E2010Manager E2010Manager exe 2 8 4 Installing E2010 Core Software 2 8 4 1 Installing the E2010 License File L Obtain a copy of the E2010 License File for the specific E2010 being upgraded This file can be obtained by contacting Pat Munson and giving her the unit serial number Copy the 2010 License File to C AT4Wireless E2010S License If this folder does not exist create it Copy the License File Installer l
50. n window click Install 5 Inthe nstallation Complete window click Next 6 Inthe Completing the AT4Toolbox nstaller_2_0 Setup window click Finish 2 8 4 4 Updating the CAL Agent 1 Inthe CAL AGENT Uninstall window shown in Figure 2 40 click Yes CAL AGENT Calibration Mode 0 3 2 10 Uninstall re you sure you want to completely remove CAL_AGENT Calibration Mode 0 3 2 10 and all of its components Figure 2 40 CAL_AGENT Uninstall Window 2 The CAL AGENT Uninstall Wizard Welcome window displays as shown in Figure 2 41 Click Next to proceed 36 8100 Mobile Device Test System LTE Product Update CAL AGENT Calibration Mode 0 3 2 10 Uninstall Welcome to the CAL AGENT Calibration Mode 0 3 2 10 Uninstall This wizard will guide you through the uninstallation of CAL AGENT Calibration Mode 0 3 2 10 Before starting the uninstallation make sure CAL_AGENT Calibration Mode 0 3 2 10 is not running Click Next to continue Figure 2 41 CAL AGENT Uninstall Wizard Welcome 3 In the Uninstall CAL AGENTwindow click Next CAL AGENT Calibration Mode 0 3 2 10 Uninstall Choose Components Choose which features of CAL_AGENT Calibration Mode 0 3 2 10 you wank to uninstall Check the components you wank to uninstall and uncheck the components you don t want to uninstall Click Uninstall to start the uninstallation Description Select components to yf PRESSI Position your mouse un
51. nal displays the following Ready to RECEIVE File TempConfigScript scr in binary mode Send several Control X characters to cancel before transfer starts CKCK 15 Use HyperTerminal to transfer the supplied configuration file by selecting TransferSend File as shown in Figure 2 66 52 8100 Mobile Device Test System LTE Product Update File Edit View Call Transfer Help 3 a Receive File Capture Text a Send Text File Capture to Printer Sends a file to the remote system li Figure 2 66 Send File Menu Command 16 In the Send File window click the Browse button and select the 8100 LTE 4 4 0 Installer Root gt Router Switch Config Files Dell6248 txt configuration file Send File Figure 2 67 Selecting a File 17 Click Send and wait for the transfer to complete 18 Once the transfer is complete HyperTerminal should display text similar to the following Configuration script validated Storing startup config to non volatile storage This operation may take a few minutes Management interfaces will not be available during this time 19 Restart the Dell Switch Enter the following command Reload 20 HyperTerminal displays Management switch has unsaved changes Are you sure you want to continue y n 21 Press y 8100 Mobile Device Test System LTE Product Update 53 22 HyperTerminal displays the following Configuration Not
52. nts Global Installer For details on how to use the Global Installer application refer to Section 2 3 To update components in the Global Installer 1 Ifthe correct version of Test Manager is not installed select the Test Manager component 2 Click the Installation toolbar button to begin the installation 3 Navigate through all the tabs from left to right and select any components that are indicated to be out of date or missing 4 Click the Installation toolbar button F to begin all installations 5 Restart the Controller PC 2 4 4 Installing Logging Framework 1 Uninstall any previous versions of Logging Framework components a Stop the Logging Framework by selecting Start All Programs AT4 Wireless Logging Framework Runtime gt Stop Logging Framework b An nformation window displays verifying that Logging Framework has been stopped as shown in Figure 2 5 8100 Mobile Device Test System LTE Product Update 15 C Information 1 Logging Framework stopped Figure 2 5 Logging Framework Information Window From the Control Panel select Add or Remove Programs and remove the following components i AT4 Wireless Logging Generator COM Interface ii AT4 Wireless Dissectors Uninstall LogAgent by selecting Start All Programs gt AT4 Wireless gt Logging Agent gt Uninstall 2 Install the Logging Framework a Navigate to the 8100 LTE 4 4 0 Installer Root eAirAccess Controller PC Logg
53. ollow these instructions if your system includes a Cisco 1811 router 1 Connect the blue RJ 45 to DB 9 cable between the CONSOLE port on the rear of the router and the COM1 serial port on a PC This blue cable should be included in the box with the router 2 Using the HyperTerminal application or equivalent communication program connect to the router on COM1 using 9600 bps 8 data bits no parity and 1 stop bit 3 Start the HyperTerminal application by selecting StartoAll Programs gt Accessories gt Communications HyperTerminal 4 Inthe Connection Description window enter Cisco in the Name field and click OK 5 Inthe Connect To window select COM1 in the Connect using field and click OK 6 Under Port Settings select the values for each setting as shown in Figure 2 59 46 8100 Mobile Device Test System LTE Product Update 7 8 10 11 12 13 14 15 Port Settings Bits per second Emi Data bits E Parity None Stop bits fi Flow control Hardware Restore Defaults ree dos Figure 2 59 HyperTerminal COM Port Settings Power on the router Wait until the router has finished initializing HyperTerminal should display the following information cisco 1811XM MPC860P processor revision 0x400 with 124928K 6144K bytes of memory Processor board ID JMX0845L1FA 879732514 M860 processor part number 5 mask 2 Bridging software X 25 software Version 3
54. ollowing features have been added to the CDMA LTE Mobility Test Packs Supports tests for measurement gaps in VZW LTE CDMA InterRAT Operations Test Plan and in VZW LTE CDMA InterRAT Operations for SVD Test Plan Supports the update for the VZW LTE CDMA InterRAT Operations Test Plan from v5 0 to v6 0 Supports VZW LTE CDMA InterRAT Operability Test Plan v1 5 Supports the operating bands 3 24 25 and 26 in addition to the operating bands that were supported in the previous release including 1 2 4 5 7 10 12 13 14 17 and 20 Supports saving eAirAccess logs within Test Manager Supports enabling RLP logging in AirAccess C2K Supports Windows 7 on the Controller PC Supports Spirent UICC Milenage 1 2 2 Data Retry LTE The following new features are included in the Data Retry LTE Test Packs Supports the operating bands 3 24 25 and 26 in addition to the operating bands supported in the previous release including 1 2 4 5 7 10 12 13 14 17 and 20 8100 Mobile Device Test System LTE Product Update 3 e Supports VZW Compliance Test Plan LTE Data Retry Version 9 0 e Supports saving eAA logs from within Test Manager e Supports Windows 7 on the Controller PC 1 2 3 Data Throughput LTE The following new features are included in this release of the Data Throughput LTE Test Packs e Supports the CQI ACK NACK Stats collection and CQI ACK NACK charts in Test Manager e Supports L1 L2
55. on the desktop ignore it 62 8100 Mobile Device Test System LTE Product Update 3 5 Creating a New Platform File Platform Files created using previous releases do not automatically upgrade correctly with this release Follow the instructions below to create a new Platform File for your test system 1 In Test Manager select FilesNew gt Platform File as shown in Figure 3 7 The B Series Platform file opens Test Manager Edit View Execute Report Help arra _NIC ue v bi CDMA LTE Mobility Verification ses 5 Mobility sui 2011 12 20 0923 XxX Summary Test Description Test Case Test Folder pi Fusssssneanenaneseeeaeaneneanessananaaneazaneeeananeaneoneneene Percentage 1 of 1 100 D of 1 0 Develog Redirection U CS8 Developer Tem CS8 SUE File Selection Session File Selection Platform File Selection Save All Ctrl Shift 5 s Debug 12 20 2011 9 25 02 AM Pending 0 of 1 0 Results Path Selection oa Other Dof 1 0 Options 5 5 to Elapsed Time HH MM SS 5 2 to Session 00 02 26 Save Ctrl S S 2 to Save As 5 to a S 5 to Type PC Timestamp Description 44HS CN SetSecurityProcedureStates AAHS ENABLED AAHS_ENAE Exit Alt F4 0 Inform 12 20 2011 9 25 02 AM Step 2 Configure UMTS 51819 Starting execution gt ln a ret P UMTS 5 to ty Debug 12 20 2011 9 25 02 4M Step 2 DevelopmentLibraryServices SS
56. onnected Could Not Find C AT4AWireless LTE_E20919 5W_LTE_SU_R1i_2_5_1 6 FINLTE Check txt Checking the final FPGAs versions at CELL A Telnet Connection Open to 18 168 8 2 Send Command cmd cd home yxllser workspace Send Command checkWersions gt CheckedUersions txt files copied 1 filets copied 1 filets copied 1 filets conied List of current FPGAs versiona DLFRE FW VERSION 83610208 IS OK DLATON FW VERSION 826461806 IS OK lt UL FW VERSION B6646081 IS OK RO FW VERSION 61686182 IS OK Could fot Find C xAT4AWIire less LTE_E20919 5W_LTE_SU_Ri 2 5 1 6supdt txt Detecting Finally all FPGAs at CELL A It could take up to 3 mins in case of a new reboot Telnet Connection Open to 18 168 8 2 Send Command cmd cd hone vxUser uorkspace Send Command devs gt output txt Send Command 22 FpgaDeuDLFRE 29 FpogaDevDLATON 30 FpgaDevRa 32 FpgaDevlL 1 files copied E2zBio with CELL A UPDATED Ful Upgrade SUCCESSFULLY finished Could Not Find C AT4wire less E26140 calibrat ionData OK ret Calibration Data SUCCESSFULLY generated but CalAgent reported a WARNING probabl y due to calibration data generated by default Press any key to continue Y Figure 2 50 Check Versions Verification 14 In the nstallation Complete window click Close 8100 Mobile Device Test System LTE Product Update 41 2 8 4 5 Applying the NetBootLoader Patch 1 Double click the Pu
57. ounter this issue use the Windows Control Panel to confirm that the correct software applications are installed 2 System Upgrade Instructions 2 1 Overview 2 2 The following sections contain the steps necessary to install the LTE Test Packs and the necessary supporting software components on an existing system These steps include Downloading and unzipping the Software Update Package from the Customer Support website Using the Global Installer application Updating the Controller PC Updating the Client Laptop Updating the Application Server Updating the EPC Server Updating the E2010S Updating the Cisco 1811 2600 Router Configuration Updating the Dell 6248 Switch Configuration Updating the Agilent ESG Updating the Agilent EXA MXA Spectrum Analyzer Installing new System Cables Downloading Unzipping the Software Update To download unzip the software update L Log in to the Spirent Customer Service Center website at http support spirent com using the e mail address and password assigned to you by Spirent Select Download Software Updates gt Wireless 8100 Radio Access LTE Testing Version 4 4 0 Download to download the latest release Locate the downloaded file in Windows Explorer 10 8100 Mobile Device Test System LTE Product Update 4 Right click the file and select Extract All from the menu as shown in Figure 2 1 Mame Qpen Search Explore Perforc
58. pplicable to version 1 40 the Data Throughput LTE Test Packs For FTP over IPv6 at maximum throughput rates greater than 25Mbps you must use a client laptop running Windows 7 and an Application Server running Windows Server 2008 The Advanced Channel Model test requires the E2010 to be calibrated for 1dB tolerance limits Call Spirent Customer Service for details A test may encounter a radio link failure when the IMS PDN is enabled and the UE refreshes its subscription by sending another SUBSCRIBE This typically happens when the test involves an FTP UDP transfer for more than 40 minutes after attach Performance degradation may be seen for high throughput test cases when RLC Stats or L1 L2 logging is enabled We recommend that you disable RLC and L1 L2 logging only if modulation is 64QAM MIMO is enabled and the TB Size is 25456 or above If the COM port of the UE is locked unplug and reconnect the UE CQI information in the CQI Chart and in the detail benchmark report is not logged for the Transmission Mode 4 and Transmission Mode 6 Test Cases In certain RF configurations the calculated MAC Physical Layer Throughput may be Slightly off and should only be used as a reference When a system is cabled with SR5500M we recommend that you use the Dedicated Mode to achieve maximum RSTP range across all band classes 1 4 4 RF Performance LTE The following issues are applicable to the RF Performance LTE Test Packs Microsoft W
59. rmissions Setting 10 Calibration procedures can now be performed on existing and or default files present in the ProgramData Spirent Communications Development Library Services folder 2 5 Upgrading the Client Laptop Connect the device containing the unzipped installer to the Client Laptop 2 5 1 Updating Spirent AT Control To update Spirent AT Control 1 Select Start gt Control PanebAdd Remove Programs Uninstall the Spirent AT Control application Navigate to the 8100 LTE 4 4 0 Installer Root eAirAccess Controller PC Spirent AT Controlfolder 4 Execute setup exe and accept the defaults 2 5 2 Updating Spirent Data Client For details on how to use the Global Installer application refer to Section 2 3 on page 11 To update Spirent Data Client 1 Startthe Global Installer application 2 Ifthe correct version of Spirent Data Client is not installed select the Spirent Data Client component 3 Click the Installation toolbar button to begin the installation 4 Restart the Client Laptop 8100 Mobile Device Test System LTE Product Update 25 2 6 Upgrading the Application Server To update the Application Server 1 Connect the device containing the unzipped installer to the Application Server 2 From the Controller PC use Remote Desktop to login to the Application Server at 192 168 0 70 2 6 1 Updating Spirent Data Client For details on how to use the Global Installer application re
60. rt 33x of the Dell 6248 switch Refer to the 8200 Setup Guide for connection guidelines 2 12 2 Synchronization Cable A new synchronization cable is required on systems containing CDMA equipment to support time synchronization between the LTE and CDMA networks Connect the supplied synchronization cable from the CDMA Trigger port of the primary SR3452 this should be the lower unit to the Cell A TRIG 2 port of the E2010S Refer to the 8200 Setup Guide for connection guidelines 3 Known Issues Details 3 1 3 2 Dell Latitude E6500 E6510 E6520 Client Laptop Issue There is an issue with removing the test data cards and test phones from Dell Latitude E6500 E6510 E6520 Client Laptops connected via the PCMCIA slot or USB The issue prevents the device from being used after removed until the client laptop is rebooted To avoid having to reboot the Client Laptop after removing a test device 1 Before removinga device plugged into the PCMCIA slot or connected via the USB port stop the device properly by selecting the Safely Remove Hardware icon from the System Tray as shown in Figure 3 1 Safely Remove Hardware Jom 12 19PM Figure 3 1 Safely Remove Hardware Icon 2 Select the desired test device to safely remove it from the Client Laptop UE Drivers that Install a Network Interface There is a potential conflict during data call setup when both the Network Interface and Dial Up Modem are enabled on the client
61. s C2K by double clicking the desktop icon 2 Select Help Enter Application Password The Application Password window displays as shown in Figure 2 12 3 Enter the appropriate password and click OK 20 8100 Mobile Device Test System LTE Product Update Application Passwords IR i SERENI Figure 2 12 Entering the AirAccess C2K Password 4 Select File gt Install Instrument Firmware 5 The SR3452 SR3462 and SR3600 Instrument windows display as shown in the following figures SR3452 Instrument Searching for emulators nstall software update SS y SPIRENT Restart emulatore Communications nstall firmware updates Power cycle emulators Figure 2 13 SR3452 Instrument Window SR3462 Instrument Contacting emulator 192 168 0 101 par SPIRENT Communications Figure 2 14 SR3462 Instrument Window 8100 Mobile Device Test System LTE Product Update 21 SR3600 192 168 0 92 LO Instrument KS Contacting emulator SPIRENT Stat instalation Communications Ready NUM Figure 2 15 SR3600 Instrument Window 6 Wait for the installation to complete A window may display prompting you to turn the instrument off and power it on again Follow the instructions to restart the instrument and close the window 7 Close AirAccess C2K 2 4 8 Correct Calibration Files Access Permissions Windows 7
62. stem and MaintenancexWindows Update gt Change Settings The Change Settings window displays 2 Underthe mportant Updates section select Never check for updates as shown in Figure 3 6 Change settings Oy x Control Panel Security Windows Update Change settings File Edit View Tools Help Choose how Windows can install updates When your computer is online Windows can automatically check For important updates and install them using these settings When new updates are available you can also install them before shutting down the computer Understanding Windows automatic updating i EN Install updates automatically recommended Install new updates Every day at 3 00 AM Download updates but let me choose whether to install them Check for updates but let me choose whether to download and install them gt il f Never check for updates not recommended Your computer will be more vulnerable to security threats and performance problems without the latest updates Recommended updates T Include recommended updates when downloading installing or notifying me about updates Note Windows Update may update itself automatically before it checks for other updates Read our privacy statement online Cancel Figure 3 6 Windows Update Change Settings 3 Click OK to save the changes and exit the window 4 fa Windows update is turned off Click to turn on message displays
63. t 8100 LTE 4 4 0 Installer Root gt eAirAccess E2010EmbeddedPC LTE E2010 Core License Installer v1 0 Release 4195 exe to C AT4Wireless E2010S License Run the License_Installer_v1 0_Release_4195 exe file to install the license The A74 Wireless Licenserwindow displays as shown in Figure 2 31 8100 Mobile Device Test System LTE Product Update 31 HE AT4 wireless Licenser DI ATA wireless Licenser 4 T LG WiRELES Load license file Figure 2 31 AT4 Wireless Licenser Window Under the 2010tab select Load License File The Open License File window displays Navigate to C A74Wireless E2010S License and select the E2010_SNBWITSxxxxxxx xml licx file where xxxxxxx is the E2010S serial number Click Open Run the License_Installer_v1 0_ Release 4195 exe file 2 8 4 2 Installing E2010S Software 1 Navigate to 87100 LTE 4 4 0 Installer Root eAirAccess E2010EmbeddedPC LTE 2010 Corel and run the LTE_E2010_Software_Package_v2 5 1 6 setup exe file In License Agreementwindow select accept the terms of the license agreement and click the Next button as shown in Figure 2 32 32 8100 Mobile Device Test System LTE Product Update LTE E2010 Signalling Unit Software Installer Setup Please review the license terms before installing LTE E2010 A T4 O Signalling Unit Software Installer WipeLess Press Page Down to see the rest of the agreement SOFTWARE LICENSE AT4 Wireless SA
64. te raro 2 1 2 1 CDMA LTE Mobility vrscsuisvestscownsesonscndaswaasceeseaseasdesebaoteteesasenveseavnansesenss 2 122 VUOLE lana 2 12 53 Daa TOn SCTE ili R EEE 3 t24 R Ferorman e LE Er EE E OE EEE EOE E 3 1 25 UMT L E MOD V aes S 4 LO Maimenance Updates cenrediiriieiericii sionin rierien EEEE 5 1 3 1 CDMA LIE MOOI vrscsctacestscowasesorscadaswavecwaseaseusdesernetetvesaseneeseasnacneaenes 5 oa PARV eC ann 5 Dees Data Tnroughpul LTE scsrserrisriser nne E ES 5 Ee NPE O AL E ra a E E E EN 5 355 UM LEMI V eE E 6 LA INTO WNICISSUE Sri nina icaro E ENE EEEE A EEE 6 ti CDMA LITE MOON etnico 6 t2 VOCALE 7 1 43 Doa OUP e LTE eE E ES 7 Lidi FPEanna E E E A in 7 45 UM L MODU VEn E E 7 2 System Upgrade Instructions iii 9 Dake CIVCIVICW aee E E AAE EE AOE 9 2 2 Downloading Unzipping the Software Update erre 9 2 3 Using the Global Installer Application cccssccssccescceccssceesceesees 11 2 4 Upgrading the Controller PC ccsccssccsscsscesccescesceesesscescesseescens 13 24i RIeparng FOr TAC Uan 13 2 4 2 Updating Intrig Data Monitof cccsscccsscccnscccnsccensccessccessccessceeees 13 2 4 3 Updating Components Global Installer cccsscccossceosscceesceesscees 14 2 4 4 Installing LOGGING FrAMEeWOFK sccesecconsccesscccnscecescecsscecescecescess 14 2 4 5 Completing Test Manager COnfiguration ccccscccoscccsssccescecescees 16 2 4 6 Completing eAirA
65. the ESG2 using 192 168 0 113 for the IP address 8100 Mobile Device Test System LTE Product Update 55 2 11 Configuring the Agilent EXA MXA Spectrum Analyzer These procedures only apply to systems equipped to execute the RF Performance LTE test cases If the Agilent ESA Series Spectrum Analyzer is part of your RACK you can skip this section To configure the Agilent EXA MXA Spectrum Analyzer 1 Login to the EXA as an administrator with the following credentials User name administrator Password agilent4u From the Control Panel select Network Connections Right click Local Area Connection and select Properties from the menu The Properties window displays Under the Generaltab select the Internet Protocol TCP IP option and click the Properties button In the Properties window select the Use following IP address option and enter the following parameters a IP Address 192 168 0 87 b Subnet Mask 255 255 255 0 c Default Gateway 192 168 0 1 Click the OK button to close all open windows If prompted power cycle the Spectrum Analyzer 56 8100 Mobile Device Test System LTE Product Update 2 12 Installing New System Cables There are two new cables are required for the 8100 system They are described in the following sections 2 12 1 Ethernet Cable A new Ethernet cable is required to support RLC logging Connect the supplied Ethernet cable from the AUX 1 port of the E2010S to po
66. ting a File Click Send and wait for the transfer to complete HyperTerminal should now display text similar to the following 6784 bytes copied in 56 084 secs 121 bytes sec Spirent router Restart the Cisco Router Enter the following command reload HyperTerminal now displays Proceed with reload confirm Press the y button 48 8100 Mobile Device Test System LTE Product Update 24 The router restarts 25 Press Enter and verify the prompt displays the configuration file part number with the correct revision 64_002863_vXX 26 The upgrade is now complete 2 9 2 Updating the Cisco 2600 Router Follow these instructions if your system includes a Cisco 2600 router 1 Connect the blue RJ 45 to DB 9 cable between the CONSOLE port on the rear of the router and the COM1 serial port on a PC This blue cable should be included in the box with the router 2 Using the HyperTerminal application or equivalent communication program connect to the router on COM1 using 9600 bps 8 data bits no parity and 1 stop bit 3 Start the HyperTerminal application by selecting Start gt All Programs gt Accessories gt Communications HyperTerminal 4 Inthe Connection Description window enter Cisco in the Name field and click OK 5 Inthe Connect To window select COM1 in the Connect using field and click OK 6 Under Port Settings select the values for each setting as shown in Figure 2 62 Port Settings Bits p
67. ys as shown in Figure 2 37 Click the Uninstall button x SU_Manager 2 6 0 15 Uninstall Choose Components Choose which features of SU_Manager 2 6 0 15 you want to uninstall Check the components you want to uninstall and uncheck the components you don t want to uninstall Click Uninstall to start the uninstallation Select components to uninstall Space required 0 0KB 474 wireless x Description SU Manager Previous F Position your mouse SU Manager A over a component to SU Manager B see its description Figure 2 37 SU_Manager Uninstall Wizard Choose Components 9 Inthe Completing the SU Manager Uninstall Wizard window shown in Figure 2 38 click Finish x SU Manager 2 6 0 15 Uninstall Completing the SU_Manager 2 6 0 15 Uninstall Wizard SU_Manager 2 6 0 15 has been uninstalled from your computer Click Finish to dose this wizard Figure 2 38 Completing the SU_Manager Uninstall 8100 Mobile Device Test System LTE Product Update 35 10 A message displays verifying that the software was successfully removed as shown in Figure 2 39 Click OK X SU_Manager 2 6 0 15 Uninstall Figure 2 39 Software Successfully Removed Message 2 8 4 3 Installing AT4 Toolbox 2 0 1 Inthe nstaller Language window select English and click OK 2 Inthe A747oolbox nstaller_2 0 Setup window click Next 3 Inthe License Agreementwindow click Agree 4 Inthe Choose nstall Locatio

Download Pdf Manuals

image

Related Search

Related Contents

CT-V900 Controller Installation Manual  Samsung GT-P7510/AM16 מדריך למשתמש  Air Data System User Manual  Memorex miniMove Mix3  ごあいさつ  Philips Cordless telephone  Radio Shack ARH7078-A User's Manual  Kingston Technology ValueRAM KVR667D2S8F5/1GHE memory module  ficha de dados de segurança (reach)  click here  