Home
2.4GHz 802.15.4 ZigBee Modules for Wireless Networking
Contents
1. the device to reach an ERP TX power equal to 0dBm giving the chance to cover an open space field of 70 meters Module conformation besides place at Users disposal a series of I O digitals and analogue inputs permitting to rise the network performance KEY FEATURES MESH configuration Network programmable parameters Data Rate 250 Kbps RF High Sensitivity 92dBm 16 available channels AES encryption to128 bits auto and transparent to the Users Very low power consumption lt 1 A in power down Tiny size 26x35mm Authomatic channels change in all the network Easy and quick nodes enlargement to improve your network Le caratteristiche tecniche possono subire variazioni senza preavviso AUR EL S p A non si assume la responsabilit di danni causati dall uso improprio del dispositivo AUREL S p A Via Foro dei Tigli 4 47015 Modigliana FC ITALY 19 05 2008 Tel 39 0546 941124 Fax 39 0546 941660 Pag 2di2 http www aurelwireless com email ricomm aurel it AUREL RELESS Absolute limits XTR ZB1 xLI Instruction manual Operating temperature range 40 C 85 C Power supply 0 3 3 6V Input Voltage 0 3 Vcc 0 3V Output Voltage 0 3 Voc 0 3V Technical Specifications Parameter Min Tip Max Value DC Levels Power Supply 2 0 3 3 3 6 V Current Consumption RX mode 33 mA Cu
2. AUG EL WIRELESS XTR ZB1 xLI Instruction manual AUREL RELEsS S S 2 4GHz 802 15 4 ZigBee Modules for Wireless Networking Applications XTR ZB1 xLI Le caratteristiche tecniche possono subire variazioni senza preavviso AUR EL S p A non si assume la responsabilit di danni causati dall uso improprio del dispositivo AUREL S p A Via Foro dei Tigli 4 47015 Modigliana FC ITALY 19 05 2008 Tel 39 0546 941124 Fax 39 0546 941660 Pag 1dil http www aurelwireless com email ricomm aurel it AUREL RELeEsSsS XTR ZB1 xLI Instruction manual FOTO del retro legenda dello short form x R Router x C Coordinator x E End Device XTR ZB1 xLI AUREL Modules has features standards based IEEE 802 15 4 and ZigBee networking protocols It works on ISM 2 4GHz and it is suits for low power long range applications thanks to chances to use networks nodes as signal repeaters It use a DSSS Direct Sequence Spread Spectrum technique that gives the opportunity to operate in even the most hard to access places and strongly reduces the interferences due to the narrowband signals Module can be connected to an external microcontroller through a serial interface that permit to sends commands for network management and for the data packets transmission see the Commands User Manual for AUREL module XTR ZB1 Module Transceiver is equipped with a PIFA antenna Planar Inverted F Antenna that permit to
3. ioni senza preavviso AUR EL S p A non si assume la responsabilit di danni causati dall uso improprio del dispositivo AUREL S p A Via Foro dei Tigli 4 47015 Modigliana FC ITALY 19 05 2008 Tel 39 0546 941124 Fax 39 0546 941660 Pag 6di 6 http www aurelwireless com email ricomm aurel it AUEL Instruction manual Module Layout 26 mm K gt PETATE EEEE ee PESEE E E R usa A XTR ZB1 xLI E E Q LO tT se 23 1 MAMAN DDO OPO PRH i D dD D Gah pi I DN Li Li Di I LI iI Li tI Ti i i o KO dd CI HI e e e ko csi A TTT E TT E AW TL tT i i i m A nial Sener U U a U U WU g E do o 2 mm i2mmi 4 mm Fig 2 Layout Le caratteristiche tecniche possono subire variazioni senza preavviso AUR EL S p A non si assume la responsabilit di danni causati dall uso improprio del dispositivo AUREL S p A Via Foro dei Tigli 4 47015 Modigliana FC ITALY 19 05 2008 Tel 39 0546 941124 Fax 39 0546 941660 Pag 7 di7 http www aurelwireless com email ricomm aurel it
4. p Radio Module Interrupt This line is normally up input pull up and when it forced 21 INTERRUPT down will run an interrupt Then Radio Module sends a message to the network coordinator seguito del quale il modulo radio invia un messaggio al coordinatore della rete see Commands User Manual for AUREL module XTR ZB1 Close Down Power Saving mode PIN for End Device Normally up when it forced 22 PWD down ED going from Power Down to ON passa dallo Stato di Power Down allo stato attivo vedi Usage Giude Demo Board XTR ZB1 Router 23 GND Connected to GND HALF and FULL Reset vedi Commands User Manual for AUREL module XTR 24 RESET ZB1 of Radio Module This line is normally up input pull up when it forced down will run a Reset Tab 1 PIN description Le caratteristiche tecniche possono subire variazioni senza preavviso AUR EL S p A non si assume la responsabilit di danni causati dall uso improprio del dispositivo AUREL S p A Via Foro dei Tigli 4 47015 Modigliana FC ITALY 19 05 2008 Tel 39 0546 941124 Fax 39 0546 941660 Pag 5di5 http www aurelwireless com email ricomm aurel it AUREL RELeEsSsS XTR ZB1 xLI Instruction manual Device Working conditions To obtain the performances specified above and enforce the conditions expressly declared onto Certifications Module must be mounted into a printed board taking into account as follow Power Supply 1 Module must be powe
5. red by a very low Voltage source protected against the short circuits Power source variation admitted 2 0 3 6V 2 Decoupling near the transmitter with ceramic capacitor of minimun capacity 100 000 pF Ground It should surrounding at best the weld area of transceiver Ground plane must be realized into the lower surface and must not be present close to the integrated antenna in order to coupling avoid Other components 1 In case of Module assembling parallel to the printed circuit doesn t print tracks close to the integrated antenna 2 Keep away the Module from the others circuit components up to 5 mm 3 away and shielded microprocessors and their clock circuits Certification requirements XTR ZB1 xLI Modules fully satisfies the European legislations EN 300 228 and EN 301 489 with max power supply of 3 6V Products are tested following the directive EN 60950 and it can be used inside a dedicated insulated containers assuring the harmony with the above standards Module must be powered by a very low Voltage source protected against the short circuits If Modules are incorporated into a product the Users must ensure the antenna insulation due output RF transmitter can t support directly the static charges foreseen by the EN 61000 4 2 standards Modules can be installed inside containers that assuring the surpassing of EN 61000 standards are not directly applicable to it Le caratteristiche tecniche possono subire variaz
6. rrent Consumption TX mode 28 mA Current Consumption power down mode 1 uA RF Characteristics Frequency Band 2405 2483 MHz Modulation Type O QPSK RX Sensitivity 92 dBm TX Output Power E R P 0 dBm Performance RF Data Rate 250 Kbps Serial Data Rate 38400 bps Outdoor range 70 m Number of channels 16 Bandwith 3 MHz Channel Spacing 5 MHz Operating temperature range 40 85 C Module Size 25x35 mm Le caratteristiche tecniche possono subire variazioni senza preavviso AUR EL S p A non si assume la responsabilit di danni causati dall uso improprio del dispositivo AUREL S p A Via Foro dei Tigli 4 47015 Modigliana FC ITALY 19 05 2008 Tel 39 0546 941124 Fax 39 0546 941660 Pag 3di3 http www aurelwireless com email ricomm aurel it DURE XTR ZB1 xLI WIRELESS Instruction manual PIN Configuration XTR ZB1 xLI 1 o 23 21 OOOOOOOOOO 000000000000 24 22 20 Fig 1 Device pinout Le caratteristiche tecniche possono subire variazioni senza pre o AUR EL S p A non si assume la responsabilit di dan sati dall uso improprio del dispositivo AUREL S p A Via Foro dei Tigli 4 47015 Modigliana FC ITALY 19 05 2008 Tel 39 0546 941124 Fax 39 0546 941660 Pag 4di4 http www aurelwireless com email ricomm aurel it AUREL RELESS XTR ZB1 xLI Instruction manual Pin De
7. scription 1 Vcc Module power supply 2 0 3 6V rightly filtrate and regulated 2 GND Connected to GND Module Hardware Reset when it s low This line is normally up input pull up and 3 Input R when it forced down will run a reset simulating a complete loss of power supply see Commands User Manual for AUREL module XTR ZB1 4 ADCI Radio Module ADC input 14 bits max resolution 5 RSTX Serial data output 6 RSRX Serial data input Request to send Output This line has brought up from module when receiver buffer is full In this case should be necessary stop serial data transmission toward module 7 RTS because some data can be missed When this line is low module can accept serial data transmission Clear to send input Module in case some data are ready to be sended through serial 8 CTS line doesn t not ship them if the line is forced high from the outside but only otherwise 9 ADC3 ADC Input 14 bits max resolution 10 GND Connected to GND 11 ADC2 ADC input 14 bits max resolution 12 ADC4 ADC input 14 bits max resolution 13 OUT 1 Digital Module output 20mA 14 OUTR Reserved Digital output that indicates If the Module is ON see Usage Giude Demo i Board XTR ZB1 Router 15 OUT 3 Digital Module output 4mA 16 OUT 2 Digital Module output 4mA 17 INI Digital Module input pull up 18 OUT 4 Digital Module output 4mA 19 IN 3 Digital Module input pull up 20 IN2 Digital Module input pull u
Download Pdf Manuals
Related Search
Related Contents
EconoPac 7300 User`s Manual Fisher 1061 - Welcome to Emerson Process Management Ask Proxima Ultralight LX1 User's Manual Samsung S5350 2.2" 99.2g Black MANUAL DEL USUARIO PATHFINDER 1999 HP Chromebook 14-q012sa Ford 2008 Expedition Automobile User Manual (M)SDS - 純正化学株式会社 製品検索・MSDS検索 baixar - Faculdade de Letras Copyright © All rights reserved.
Failed to retrieve file