Home
263040 S-Digit Mini+ - York Survey Supply Centre
Contents
1. A 3 1 1 Power Power the instrument ON OFF 2 Hold IIlumination Press the button short to freeze the current reading Press the button long to switch on off the illumination 3 Mode Press the button short to select 5 different display modes see Additional Functions Ref operat98 instructions 15 263040 qxp 05 01 15 4 Cal Sound Press the button short to switch on off the signal tone Press the button long to switch on the calibration mode see Check of Calibration 5 6 g 10 5 Direction symbol approaching the 0 90 position 6 Symbol sound on off 7 Battery status indicator 8 Unit symbol N FT 9 Unit symbol 10 Unit symbol mm m IMPORTANT Calibration of inclinometer before first use before important measurements after a hit or drop after a large fluctuation in temperature CHECK OF CALIBRATION Set the instrument down on a flat and even surface and switch it on Wait 3 seconds and note down the measured value A Turn the unit by 180 and set it down on the same position as before Wait 3 seconds and note down the meas ured value B If the deviation between the two values A and B is more than 0 2 the unit has to be calibrated CALIBRATION Set the instrument down on the same flat and even surface switch it on and keep the button CAL SOUND pressed until the display shows 0 Wait approximately 3 seconds and press the button CAL SOUND again u
2. York Survey Supply Centre 2015
3. children Do not use the instrument in explosive environments The user manual must always be kept with the instrument SPECIFIC REASONS FOR ERRONEOUS MEASURING RESULTS Measurements through glass or plastic windows dirty laser emitting windows after the instrument has been dropped or hit please check the accuracy Large fluctuation of temperature If the instrument will be used in cold areas after being stored in warm areas and vice versa please wait some minutes before carrying out measurements ELECTROMAGNETIC ACCEPTABILITY EMC It cannot be completely excluded that this instrument will disturb other instruments e g navigation systems will be disturbed by other instruments e g intensive electromagnetic radiation nearby industrial facilities or radio transmitters CE CONFORMITY Instrument has the CE mark according to EN 61326 1997 EN 55022 EN 61000 4 2 3 WARRANTY e The product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two 2 years from the date of purchase e During the warranty period and upon proof of purchase the product will be repaired or replaced with the same or similar model at manufacturer s option without charge for either parts or labour e In case of a defect please contact the dealer where you originally purchased this product The warranty will not apply to this product if it has be
4. SS eee ae k PT SE ns I ry i Nothing else measures up Prospect House George Cayley Drive Clifton Moor York England YO30 4XE Tel 44 0 1904 692723 Fax 44 0 1904 690385 E Mail sales yorksurvey co uk YorkSurvey for secure online ordering of all our products Ref operat98 instructions 15 263040 qxp 05 01 15 Survey Supply S Digit Mini Inclinometer Code 263040 Operating Instructions ANTANN York Survey Supply Centre 2015 S Digit Mini Inclinometer SUPPLIED WITH e Electronic inclinometer S Digit Mini e Padded bag e Batteries e User Manual FUNCTIONS Electronic slope measurer for measuring inclinations slopes and plane surfaces Technical Data Working range 4 x 90 Resolution 0 1 0 1 Accuracy 0 90 0 1 1 89 0 2 Power supply 3x AAA alkaline batteries Operating time 600hrs Size 156 x 56 x 31mm Weight 0 3kg incl batteries POWER SUPPLY Replace the batteries Open the battery compartment cover and insert the batteries ensure correct polarity When replacing the batteries always power off the instrument When the batteries have been replaced eee the instrument will power on automatically Display indication GOOD then 0 Now a calibration must be made see Check and Calibration Important If the battery symbol flashes the batteries need to be replaced FEATURES
5. d SPECIAL FEATURE WITHIN THE RANGE OF 0 90 0 setting in any position required In the range between 0 and 90 the ZERO layer can be defined in any position Start the calibration function in the position required press CAL SOUND longer than 3 seconds wait 3 seconds press CAL SOUND again wait 3 seconds press CAL SOUND again finalised Do not turn the S Digit Mini during this process Now the ZERO layer is defined in the new position and the application required can be started ATTENTION We recommend to define the ZERO layer in the horizontal position again when you have finished your application Otherwise it may happen that for the following measurements the results can be completely wrong e g when you work the next day or if another user is working with the unit SAFETY NOTES CARE AND CLEANING Handle measuring instruments with care Clean with soft cloth only after any use If necessary damp the cloth with some water If the instrument is wet clean and dry it carefully Pack it up only if it is perfectly dry Transport in original container case only SAFETY INSTRUCTIONS Follow the instructions given in the user manual Use the instrument for measuring jobs only Do not open the instrument housing Repairs should be carried out by authorised workshops only Please contact York Survey Supply Centre Do not remove warning labels or safety instructions Keep the instrument away from
6. en misused abused or altered Without limiting the foregoing leakage of the battery bending or dropping the unit are presumed to be defects resulting from misuse or abuse EXCEPTIONS FROM RESPONSIBILITY e The user of this product is expected to follow the instructions given in operator s manual Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the products accuracy and general performance The manufacturer or its representatives assumes no responsibility of results of a faulty or intentional usage or misuse including any direct indirect consequential damage and loss of profits The manufacturer or its representatives assumes no responsibility for consequential damage and loss of profits by any disaster earthquake storm flood etc fire accident or an act of a third party and or a usage in other than usual conditions The manufacturer or its representatives assumes no responsibility for any damage and loss of profits due toa change of data loss of data and interruption of business etc caused by using the product or an unusable product The manufacturer or its representatives assumes no responsibility for any damage and loss of profits caused by usage other than explained in the user s manual The manufacturer or its representatives assumes no responsibility for damage caused by wrong movement or action due to connecting with other products
7. ntil the display shows 1 Turn the unit by 180 and set it down on the same position as before Wait approximately 3 seconds and press the button CAL SOUND again until the display shows 2 Now the calibration is completed MEASUREMENT OF INCLINATION The two arrows in the display indicate in amp which direction the instrument has tobe O3 moved in order to reach the 0 or 90 position iil The exact 0 or 90 position is shown by double arrows aliji cI CJ ailli The display has an automatic digit inversion for overhead measurements ADDITIONAL FUNCTIONS Automatic shut off If no button is used for 20min the instrument will power off automatically Sound Switch the sound function on The instrument will now show by a sound signal if the horizontal or vertical position approaches The closer the position is the denser the sound signal will be If the instrument is in correct vertical or horizontal position the sound will be continuous Mode functions 1 5 1 Slope indication in 14 5 3 Indication IN FT 3 1 8 IN FT 4 Indication IN FT 3 10 IN FT 5 Indication mm m 258 9mm m Keep the mode button pressed to have all mode functions switch fast The display will not show any values Release the mode button to return to the standard indication CONNECTION TO CAMERA TRIPOD With 1 4 thread at the bottom side S Digit Mini can be connected to a camera tripo