Home

User Manual - Leakage Detection DRV3

image

Contents

1. Figure 6 Rear view of docking station effigis com Figure 7 Rooftop antenna connexions NOTE The link with the DRV3 s tuners is made through the two small round con nectors on the front of docking station which align with the 2 holes protected by the slider located at the back of the DRV3 The slider automatically opens when docked Do not insert any foreign objects into the sliders 2 4 6 Speaker The DRV3 is equipped with a speaker that emits an audio tone through the openings at the rear of the unit to provide audio feedback of RF measurements Most of the time the read ings from both bands will be different The audio tone will always reflect the highest leakage measurement 2 4 7 Battery The DRV3 is powered by a Li lon 7 2 V 3 1Ah battery pack that has a 5 pin connector to in terface with the unit Even though the battery pack may not be fully charged when the DRV3 is shipped your unit is ready to use out of the box For information on charging the battery see section 4 4 Charging the Battery on page 31 Operation Manual 15 CPAT CONTINUOUS MONITORING SYSTEM 3 Setup 3 1 Docking Station Installation 3 1 1 Safety Precautions for Installation Never install this product in places where or in a manner that it could injure the driver or passengers if the vehicle stops suddenly ever install this product in places where or in a manner that it may interfere with the driver s operation of the vehicl
2. 1 888 495 6577 International 1 514 495 0018 Fax questions anytime to 1 514 495 4191 cpat effigis com 1 5 Calibration Your DRV3 unit has been calibrated and tested in the factory and does not need further calibration before use However if the unit suffers damage or is repaired it is recommended that the unit be cali brated by an authorized Effigis service center As well if your company requires regular calibration of all equipment or requires a calibra tion certificate for the DRV3 a calibration service is available through Effigis For more information on calibration services please contact your Effigis representative 1 6 Effigis Website Effigis website contains product specifications information press releases brochure down load and Frequently Asked Questions FAQs Please visit our website at http effigis com DRV3 effigis com 2 System Components The DRV3 is a portable signal leakage detection meter designed to operate in all digital cable networks It functions as a portable dual band find and fix meter and as a monitoring probe when part of the CPAT FLEX system It is frequency agile from 118 to 140 MHz Mid band tuner and from 572 to 960 MHz LTE band tuner The DRV3 can easily be set up via its intuitive user interface This section describes the DRV3 unit in detail including its accessories and helps you get started by explaining the features the use of the buttons and the powering and
3. 6 1 5 CalibratlOniss sews bed bd ha ae gees 6 1 6 WeDSItC irer t eS 6 2 System lt 7 2 1 Initial Verification 7 2 2 DRV3 Optional 9 2 2 1 ANNAS o re ka a Li a a aa ee 9 2 3 rai es 9 2 4 Physical Overview 10 24A STAND 2 caw da ae i 10 2 4 2 Front View Buttons and Display 10 2 4 3 Power and Data Interface 11 2 4 4 Docking Station optional 11 2 4 5 Antenna 13 2 4 6 15 24 7 sved as esse nea 15 3 SQUID ss ss eee eRe ee RR RR 16 3 1 Docking station installation 16 3 1 1 Safety Precautions for Installation 16 3 1 2 Installing the Docking Station 16 3 2 DRV3 19 3 2 1 Accessing and Navigating the Setup Menus 19 3 2 2 Setting 20 3 2 3 Setting up Proximity 21 3 2 4 Setting up Bands 21 3 2 5 Setting up Sound 22 3 2 6 Setting up Units 23 3 2 7 Sett
4. Antenna Accessories Description 112 00004 100 Mid Band Monopole Quarter wave VHF Antenna Kit includes magnetic base whip antenna BNC terminated cable 112 00009 100 LTE Monopole Quarter wave Antenna Kit includes magnetic base whip antenna SMA terminated cable 2 3 Features The DRV3 is a high performance dual band find and fix leakage detection meter that offers many features including e Fully agile in both bands from 118 140 MHz Mid band tuner and 572 960 MHz LTE band tuner e User adjustable frequency displayed in 100 Hz steps e 3 favorite frequency presets e Based on Effigis s CPAT leakage monitoring system technology NOTE In both bands leakage detection is based on signal tag recognition to filter noise from real leakage points This means that monitored frequencies must be tagged in order to detected leakage See your documentation on the DSG1 module for more details on tagging channels Operation Manual 9 CPAT CONTINUOUS MONITORING SYSTEM 2 4 Physical Overview 2 4 1 Startup When you press the on off button hold 3 sec the DRV3 begins to load its operating software and parameters During this process the power light on the top right of the DRV3 flashes green and red briefly then remains lit green The battery indicator light turns green briefly as the unit checks the battery then changes to indicate powering as follows Green Plugged in and fully charged operating on external power O
5. 00010 001 12 VDC power supply 008 00002 001 Battery pack 111 00022 001 Mid band rubber duck antenna BNC connector 11 00031 001 LTE band 572 698 MHz rubber duck antenna 11 00007 001 LTE band 698 806 MHz 1 00008 001 LTE band 806 866 MHz 11 00020 001 LTE band 821 902 MHz rubber duck antenna SMA connector 11 00025 001 LTE band 902 960 MHz rubber duck antenna 6 150 00032 001 Vehicle docking station 7 150 00031 001 DRV3 8 012 00020 011 Docking station s Flex post 9 100 00001 001 DRV3 user manual One of these antennas Part number changes according to frequency ordered by customer To place an order please call Effigis at 1 888 495 6577 or 1 514 495 0018 a kh OND a SMA connector rubber duck antenna SMA connector 4 rubber duck antenna SMA connector SMA connector DRV3 8 effigis com 2 2 DRV3 Optional Accessories 2 2 1 Antennas The DRV3 comes with two rubber duck antennas for leakage detection The one with the BNC connector is for the Mid band The one with the SMA connector is for the LTE band However other antennas available from Effigis can also be used NOTE Only antennas obtained from Effigis can be used effectively with the DRV3 Each Effigis antenna has been analyzed and the appropriate compensation has been designed into the DRV3 for optimal results Effigis cannot guarantee proper results with an antenna from any other source Part No
6. Calibration Services e Equipment Return Authorizations Contact a Customer Support representative through your local distributor or by accessing http effigis com for information on calibration and warranty policies B 1 1 Equipment Return Instructions Please contact your local Customer Support location via telephone for Return Authorization to accompany your equipment For each piece of equipment returned for repair attach a tag that includes the following information Owner s name address and telephone number e The serial number product type and model e Warranty status If you are unsure of the warranty status of your instrument con tact Effigis Customer Support e A detailed description of the problem or service requested e The name and telephone number of the person to contact regarding questions about the repair e The return authorization RA number If possible return the equipment using the original shipping container and material If the original container is not available the unit should be carefully packed so that it will not be damaged in transit when needed appropriate packing materials can be obtained by con tacting Effigis Support Effigis is not liable for any damage that may occur during shipping The customer should clearly mark the Effigis issued RA or reference number on the outside of the package and ship it prepaid and insured to Effigis DRV3 34 effigis com Equipment repaired or repl
7. data inter faces on the unit 2 1 Initial Verification Your DRV3 unit is charged calibrated and ready to use right out of the box Upon reception visually inspect each item for any damage that may have occurred during shipping If you see any signs of physical damage please contact Effigis e Callers from the U S and Canada can dial 1 888 495 6577 toll free number e International callers can dial 1 514 495 0018 If there are no apparent signs of physical damage turn on the unit by pressing the a but ton approximately 3 seconds and make sure the unit boots up properly Make sure no items are missing Your package should contain all the standard items as well as any accessories you may have ordered If you ordered the DRV3 portable leakage detec tion meter kit the following items are included e DRV3 meter including its rechargeable battery pack e Rubber duck antenna for Mid band measurements with BNC connector e Rubber duck antenna for LTE band measurements with SMA connector e Vehicle docking station e Docking station s flex post e AC adapter e User manual Operation Manual 7 CPAT CONTINUOUS MONITORING SYSTEM sl 1 3 45 Figure 1 DRV3 portable leakage detection meter kit If any of the standard accessories are lost or damaged you can order a replacement for the DRV3 Please quote the following part numbers when placing an order Part No Accessory Description 110 00005 001 AC adapter 110
8. tag This value in dB al lows you to more accurately discriminate the tag signal from the channel s noise floor The DRV3 will look for a tag signal that is stronger than the channel noise by the number of decibels you configure in the Threshold setting Highlight Threshold press the right arrow gt and then use the arrow keys to edit each digit of the threshold value for the channel tag from 10 to 99 Press Enter when you are done editing 5 Enable or disable tag detection according to your needs If tag detection is not already ac tive enable it by highlighting AM and then press Enter again to enable tag detection An asterisk appears indicating that this mode of detection is now active In measurement mode the letter t appears when the DRV3 detects the tag in the frequency it is monitor Operation Manual 25 CPAT CONTINUOUS MONITORING SYSTEM ing To disable tag detection highlight OFF and press Enter An asterisk appears next to the OFF option indicating that tag detection is now disabled 6 Press Esc until you return to measurement mode or press the left arrow 4 to return to the settings menu and continue configuring other parameters 3 2 9 Setting up Detection You can configure a minimum threshold for leaks in the Mid or LTE bands before the DRV3 considers that there is leakage The possible values are from 010 to 099 uV per meter The signal leak s strength must be equal to or greater tha
9. the units of measure to the snapshot feature see section 4 3 Using the Snapshot Feature on page 31 depending on which units you have selected Operation Manual 23 CPAT CONTINUOUS MONITORING SYSTEM To change the units of measure 1 In the settings menu page 2 select Units 2 Press the right arrow then toggle between dBuV m using the up and down arrows 3 Press Enter to save your choice The cursor automatically returns to the left column 4 Continue editing other parameters if desired or press Esc to return to measurement mode 3 2 7 Setting up Frequencies You can configure three 3 preset leakage monitoring frequencies for each of the DRV3 s bands These frequencies vary from one operator to another and can vary within different areas of the operator s network Make sure that the frequencies you configure in the DRV3 match the leakage monitoring pilot signals used by the operator NOTE Selected frequencies and tagging parameters must match the ones used with the 0501 installed at the headend in order to obtain leakage measurements To edit any preset frequency and select the active monitoring frequency 1 In the settings menu page 2 select Frequency 2 Press the right arrow gt to access the band and frequency options 3 Select the desired band Mid Aero or LTE and then press the right arrow to display the list of preset frequencies Freq 1 Freq 2 and Freq 3 T
10. to 960 MHz LTE band Channel tuning Configurable via USB port and by front panel buttons Level range 2 to 2 000 V m meters Mid band 5 uV m to 2 000 meters LTE band Level accuracy 1 5 dB Mid Band 2 5 dB LTE Band Adjustable audio volume RF level scale display Measurement units A 2 Electrical and Environmental Pack of 2 rechargeable Li lon cells 3 100 mAh Charging temperature 0 to 45 C 32 to 110 Operation time 2 5 hours nominal both tuners activated or 4 0 hours nominal one tuner activated A 3 Physical 21 cm x11 cm x 4 8 3 x 4 3 x 1 6 HX WX D Weight 850 g 30 ounces Docking Station Dimensions 24 cm x 12 5 cm x 8 cm 9 4 X 4 9 X 3 2 HXW XD Docking Station Weight 240g 9 ounces Specifications subject to change without prior notice Operation Manual 33 CPAT CONTINUOUS MONITORING SYSTEM Appendix Our Services Effigis offers a portfolio of services to deploy and support purchased equipment through its Customer Support organization Customer Support is standard with every product sale and consists of business hour technical assistance in warranty repair and calibration B 1 Customer Support Customer Support is accompanied with the sale of every Effigis product Customer Support services include e Product and Service Literature e Technical Assistance business hours e Equipment Repair Under Warranty Repair and
11. ED or HIGH or the sound can be turned off with the mute option In measurement mode the DRV3 s current volume setting is shown on screen with the following icons Low Medium High Mute X NOTE You can use the Esc key to toggle between Mute and the reference volume low medium or high However to change the reference volume you must use the setup menu Squelch In order to prevent the DRV3 from emitting a tone for very low signal readings the DRV3 is equipped with a squelch feature that allows you to adjust a threshold level so only measured signals that are stronger than the selected threshold will trigger an audible tone You can configure a threshold from 0002 to 2000 in By default the DRV3 uses V m as its unit of measure DRV3 22 effigis com Rules Governing Sound In addition to the squelch level criteria there are tag detection rules associated with the DRV3 s audible tone function If you are using channel tags to identify specific CATV networks for leakage detection the DRV3 will take these tags into account before generating a tone when leakage is detected at a given frequency See section 3 2 8 Using Channel Tag Detec tion on page 25 for information in enabling the tag detection feature in the DRV3 Tag Detection Aero LTE Squelch threshold Tone Generated strongest signal ected either band Yes strongest signal detected other bana Enabled and tag detected B
12. Manual 19 CPAT CONTINUOUS MONITORING SYSTEM 3 2 2 Setting up Antennas The DRV3 uses 2 sets of antennas for each band Mid Aero and LTE bands The DRV set allows you to specify parameters for the antennas connected directly to the connectors on top of the DRV3 The roof set is for the antennas connected to the docking station linked via cables to antennas on the vehicle s roof or other external antennas NOTE Do not change the antenna type in the DRV3 unless you are physically con necting a different antenna The DRV3 comes with rubber duck antennas and this is the default antenna type for leakage detection in portable mode Effigis offers other types of antennas that can be used with the DRV3 Regardless of the antenna you are using it is very important to make sure the DRV3 s settings match the actual antenna type connected to the unit in order to accurately measure signal strength Using an antenna that is not authorized by Effigis or setting up the DRV3 with the wrong antenna type will result in erroneous readings To change the antenna type 1 In the settings menu page 1 select Antennas 2 Press the right arrow gt or the Enter button then scroll through the antenna types using the up and down arrows until you have highlighted the antenna connection you want to edit The possible values are e AERO ROOF AERO DRV e LTE ROOF e LTE DRV 3 Select the type of antenna that is physicall
13. Portable Digital Leakage Detector Operation Manual DRV3 I CPAT orv3 effigis v1 1 2014 11 20 2014 Effigis All rights reserved 006 000037 103 Rev CPAT CONTINUOUS MONITORING SYSTEM This document provides information proprietary to Effigis and cannot be used or disclosed without Effigis written authorization Effigis reserves the right to make changes without notice Changes affecting the operation of any component in this manual will be reflected in a subsequent revision Effigis assumes no responsibility for any omissions or errors that may appear in this document or for any dam ages that may result from the use of information contained herein DRV3 User Manual First edition v1 0 September 2014 Second edition v1 1 November 2014 Part No 100 00001 001 Published by Effigis 4101 Molson St Suite 400 Montreal Quebec CANADA H1Y 311 Telephone 1 514 495 0018 Toll free North America 1 888 495 6577 Fax 1514 495 4191 Copyright 2014 Effigis All rights reserved DRV3 effigis com Contents 1 General 5 1 1 About this 5 1 2 Explanation of Symbols Used 5 1 3 Certifications Seas wees dae wade ein aie 5 1 3 1 Tests Specifications 5 1 3 2 FCC Part 15 Class 5 1 4 Technical Support
14. aced under warranty will be returned at Effigis expense to Cus tomer Canada USA or Effigis representative all other countries All other non warranty repairs will be returned at Customer s expense to Customer Canada USA or Effigis representative all other countries B 2 Limited Product Warranty B 2 1 Hardware Effigis warrants to the original end user Customer that the new Effigis branded products will be free from defects in workmanship and materials under normal use for one 1 year from the date of original shipment Effigis warrants repaired products for ninety 90 days from date of shipment Any Product repaired or replaced under warranty is only warranted for the period of time remaining in the original warranty for the Product Any third party products including software included with Effigis products are not covered by this Effigis warranty and Effigis makes no representations or warranties on behalf of such third parties Any warranty on such products is from the supplier or licensor of the product B 2 2 Software Effigis warrants to the Customer that new Effigis branded software and firmware will perform in substantial conformance to program specifications for a period of ninety 90 days from the date of original shipment Effigis warrants the media containing software against failure during the warranty period Effigis makes no warranty or representation that the operation of the software products w
15. ct the desired band Mid Aero or LTE and then press the right arrow to move the cursor to the right column so you can edit each digit from 00 to 99 You can also edit the positive or negative sign that indicates if the offset to be applied is to be added or DRV3 effigis com subtracted to the measured value Press Enter when you done editing in order to save the new value 4 Repeat step 3 for the other band as applicable 5 Press Esc until you return to measurement mode or press the left arrow 4 to return to the settings menu and continue configuring other parameters 3 2 11 Setting up the Backlight This parameter allows you to determine if the backlight is always on always off or if it turns off after a certain period of no keypad activity To adjust the backlight properties 1 In the settings menu page 4 select Backlight The current setting is displayed to the right 2 Press the right arrow to move to the options and use the up and down arrows to select the backlight properties from the available options Remains on i AUTO 10s Turns off after 10 seconds if no keys are pressed AUTO 30s Turns off after 30 seconds if no keys are pressed AUTO 60s Turns off after 60 seconds if no keys are pressed No backlight 3 Press Enter to save your choice 4 Press Ese until you return to measurement mode or press the left arrow 4 to return to the settings menu and continue configuring other parame
16. e or select another item in the settings menu and continue configuring other parameters 3 2 4 Setting up Bands The band setting is used to select the frequency ranges over which you are looking for leak age The DRV3 is fully agile over two bands a mid range band from 118 140 MHz and an LTE band from 572 960 MHz By default the DRV3 is set up for both bands and your DRV3 screen is split in two when in measurement mode in order to display values for both bands If you enable only one of the bands the screen is not split and only one leakage signal level is displayed Operation Manual 21 CPAT CONTINUOUS MONITORING SYSTEM NOTE Using only one band will reduce power consumption by 30 to 40 allowing longer battery autonomy To select the detection band 1 In the settings menu page 1 select Bands 2 Press the right arrow P to toggle between Aero LTE default Aero mid range or LTE 3 Press Enter to save the value The cursor automatically returns to the left column Continue configuring other parameters if desired 4 Press Esc to return to measurement mode 3 2 5 Setting up Sound Reference Volume The DRV3 can emit an audible tone to provide an audio feedback of measurements The volume setting affects the basic reference level for the tone During normal use unless the mute option is used the tone increases with the leak s signal strength The reference volume of the tone can be set to LOW M
17. e such as on the floor in front of the driver s seat or close to the steering wheel or shift lever Make sure there is nothing behind the dashboard the floor or the paneling when drilling holes in them Be careful not to damage fuel lines brake lines electronic components communication wires or power cables When using screws do not allow them to come into contact with any electrical leads To ensure proper installation use the supplied parts in the manner specified If any parts other than the supplied ones are used they may damage internal parts of this product or they may work loose and the product may become detached t is extremely dangerous to allow the cables to become wound around the steering column or shift lever Be sure to install this product its cables and wiring away in such a way that they will not obstruct or hinder driving Make sure that leads cannot get caught in a door or the sliding mechanism of a seat result ing in a short circuit Do not install this system where it may i obstruct the driver s vision ii impair the perfor mance of any of the vehicle s operating systems or safety features including airbags hazard amp buttons or iii impair the driver s ability to safely operate the vehicle Never install the system in front of or next to the place in the dash door or pillar from which one of your vehicle s airbags would deploy Please refer to your vehicle s owner s manual for ref
18. erence to the deployment area of the frontal airbags Do not install the system in a place where it will impair the performance of any of the ve hicle s operating systems including airbags and headrests 3 1 2 Installing the Docking Station The docking station is designed to allow simple connection disconnection of the DRV3 from power data and external RF antennas It typically mounts on a flex post secured to the ve hicle s passenger floor near the 12V power source so the DRV3 can remain in the support bracket while charging You will require 3 screws not included to secure the flex post to the floor DRV3 effigis com Figure 8 Docking station used in service vehicle CAUTION Do not disconnect or modify any vehicle security systems such as airbags or seatbelts Security systems wires use yellow sleeves and yellow connectors Accidental triggering of these systems may cause severe injuries Operation Manual CPAT CONTINUOUS MONITORING SYSTEM To install the support bracket 1 Install the Flex post e Firmly attach the Flex mount bracket to the vehicle floor using 3 metal screws not included Screw the post into the bracket e Affix the flex post to the bracket with the hexagonal screw 2 Attach the docking station e Attach the DRV3 docking station to the Flex post assembly using the 4 pan head Phillips screws included with the docking station e Adjust docking station s angle and orientat
19. ght of the letter F Press Esc until you return to measurement mode or press the left arrow 4 to return to the settings menu to configure or view other parameters 3 2 15 Displaying the DRV3 s Device ID This menu item provides a view only access to the DRV3 s identification To view the device ID go to the settings menu page 5 The unit s ID is displayed to the right Press Esc until you return to measurement mode or press the left arrow 4 to return to the settings menu to configure or view other parameters DRV3 28 effigis com 4 Operation and Maintenance 4 1 Reading the Measurement Mode Screen The DRV3 starts up in measurement mode by default and immediately detects and displays levels for the last frequency selected Unless the DRV3 has been set up for single band detection it simultaneously monitors the selected frequencies in the Mid band and the LTE band In both modes the top portion of the screen shows the same information as follows from left to right Volume Shows reference volume level for audible alert upon detecting leaks that exceed squelch criteria Four 4 settings mute low medium and high See Sounds section to set up refer ence level and squelch criteria Measurement Units Leakage signal strength referenced in these units User configurable via settings menus See section 3 2 6 Setting up Units on page 23 Battery Charge Status Indicates charge dark fill when opera
20. hall at its sole discretion i repair or replace the non conforming Product to remedy the nonconformity identified by Customer in accordance with this Section Limited Product Warranty or ii issue a credit to Customer for the amounts paid for the Product in exchange for return of the non conforming Product in which case Customer s licenses to any Firmware shall be automatically revoked Customer hereby transfers to Effigis title and ownership of any parts that Effigis replaces B 2 6 Disclaimer THE REMEDIES EXPRESSLY PROVIDED IN THIS SECTION WILL BE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES AND SHALL BE IN LIEU OF ANY OTHER RIGHTS OR REMEDIES CUS TOMER MAY HAVE AGAINST EFFIGIS WITH RESPECT TO ANY NON CONFORMANCE OF PRODUCTS EXCEPT AS SPECIFIED IN THIS LIMITED PRODUCT WARRANTY EFFIGIS MAKES NO EXPRESS REPRESENTATIONS OR WARRANTIES WITH REGARD TO ANY PRODUCT EFFIGIS DISCLAIMS ALL IMPLIED WARRANTIES CONDITIONS AND REPRESENTATIONS IN CLUDING BUT NOT LIMITED TO ANY WARRANTIES OR CONDITIONS OF MERCHANTABILITY SATISFACTORY QUALITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGE MENT REGARDLESS OF THE LEGAL THEORY ON WHICH SUCH IMPLIED WARRANTY MAY BE BASED INCLUDING WITHOUT LIMITATION CONTRACT COURSE OF DEALING USAGE OR TRADE PRACTICE DRV3 36 effigis com Operation Manual 37 CPAT CONTINUOUS MONITORING SYSTEM CEAT FLEX DRV3 Docking Station Installation Flex mount post Install the Flex post 1 Fi
21. he frequency that is currently used is indicated with an asterisk 4 edit any preset frequency scroll through the list until you have highlighted the desired preset and press the right arrow gt You can now use the right and left arrows to move the cursor to the desired digit in the frequency and then use the up and down arrows to change the value The new frequency must be within the tuning range of the 118 MHz to 140 MHz mid band or 572 MHz to 960 2 band 1 Hz steps 5 To save the new frequency press Enter If you press Ese while modifying a frequency this cancels any changes you made and brings the cursor back to the list of presets 6 Repeat steps 3 to 5 to set up all three presets for each band 7 To select the frequency that you want to use for leakage detection scroll through the list of preset numbers until you find the one that corresponds to the desired frequency and press Enter The asterisk appears next to this preset DRV3 24 effigis com 8 Press Esc until you return to measurement mode or press the left arrow 4 to return to the settings menu and continue configuring other parameters 3 2 8 Using Channel Tag Detection In order to use the DRV3 s channel tag detection feature you must have a channel tagger de vice such as the 0561 that inserts tags in specified channels carried on the CATV network Channel tagging is commonly used in areas where more than
22. ill be uninterrupted or error free or that all defects in the software products will be corrected B 2 3 Exclusions This warranty excludes e Damage to the physical surface of the product including cracks or scratches to any part e Damage caused by misuse neglect improper installation or testing unauthorized attempts to open repair or modify the product or any other cause beyond the range of the intended use e Use of the product with any non recommended device or service if such device or service causes the problem e Installation or maintenance of Product by someone other than Effigis or persons certified by Effigis Operation Manual 35 CPAT CONTINUOUS MONITORING SYSTEM e Changes to the Customer environment in which Product was installed e Damage caused by accident fire power changes other hazards or acts of nature e Consumable Product or parts thereof e g parts with an expected useful life of less than ninety 90 days such as certain batteries e Product not returned in accordance with Effigis RA procedure B 2 4 Refurbished Parts and Prior Testing Product may incorporate reconditioned or refurbished parts or subassemblies and may have been used in testing prior to sale B 2 5 Exclusive Remedies If any Product materially fails to conform to the limited warranty set forth in this Section Limited Warranty and actually fails during the applicable warranty period and under normal use Effigis s
23. ing up Frequencies 24 3 2 8 Using Channel Tag Detection 25 Operation Manual 3 CPAT CONTINUOUS MONITORING SYSTEM 3 2 9 Setting up 26 3 2 10 Setting up the CW to QAM Delta 26 3 2 11 Setting up the 27 3 2 12 Setting up 27 3 2 13 Displaying DRV3 s Internal Temperature 28 3 2 14 Displaying the DRV3 s Version 28 3 2 15 Displaying the DRV3 device ID 28 4 Operation and 29 4 1 Reading the Measurement Mode Screen 29 4 2 Adjusting Volume During Normal Use 30 4 3 Using the Snapshot Feature 31 4 4 Charging the Battery 31 4 5 Replacing the Battery 31 4 6 Updating the DRV3 s Firmware 32 4 7 CICANING esra 32 Appendix A 33 1 TechniCal ssenari begga ee gee cede twee eee 33 A 2 Electrical and 33 Physical eed es angen eee 33 Appendix Our 34 B 1 Customer 34 B 1 1 Equipment Return Insrtuctions 34 B 2 Li
24. ion and tighten the thumbscrew to se cure it in this position 3 Connect the docking station cables e Connect the SMA cable from the vehicle roof antenna LTE band to the top right RF interface e Connect the BNC cable from the vehicle roof antenna Mid band to the top left RF interface e Plug in the DC cable to power vehicle accessories Plug in the USB cable required only if the DRV3 is used with an 4 e Secure cables with a cable tie 4 Connect the DRV3 to ARD4 optional e If you are using the ARD4 module connect the other end of the USB cable from the docking station to the ARD4 5 Insert the DRV3 into the docking station e Start by first sliding the bottom of the unit into the station e Then gently press the top of the unit until the DRV3 slides under the top clip You will hear a click when the clip engages For further details see the installation diagram on page 38 DRV3 18 effigis com 3 2 DRV3 Parameters When used in autonomous measurement mode with the optional ARD4 module all operat ing parameters are set automatically by the ARD4 NOTE In autonomous measurement mode access to menus is blocked to prevent any changes to operating parameters The menus are available as soon as you exit this mode NOTE After being set up in autonomous mode the autonomous mode parameters will stay active until the user provides new settings When used as find and fix tool the parameters a
25. mited Product Warranty 35 B 2 1 Hardware 35 2 2 50 wages cee ew ee be ee 35 B 2 3 EXCIUSIONS be s be eS 35 B 2 4 Refurbished Parts and Prior Testing 36 B 2 5 Exclusive 36 B 2 6 36 DRV3 effigis com 1 General Information 1 1 About this Manual This manual describes the features operation and setup of the DRV3 digital portable leakage detection meter You will find important safety information in this manual We strongly recommend that all users read this manual Use of this product other than for its intended application may com promise the unit s safety features 1 2 Explanation of Symbols Used The following symbols are used in this Manual Symbol Explanation Direct current Caution Indicates that operations or procedures if carried out without caution may cause personal injury or damage to the unit Note Indicates additional information about the product 1 3 Certifications This section describes the certifications the DRV3 complies with 1 3 1 Tests Specifications FCC 47 CFR Part 15 Subpart Verification ICES 003 NMB 003 Issue 4 February 2004 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 Generic requirements 1 3 2 FCC Part 15 Class This de
26. n the value you configure in this setting in order for the DRV3 to indicate leakage To edit detection levels 1 In the settings menu page 3 select Detection The current detection setting is displayed to the right 2 Select the band Mid Aero or LTE for which you want to edit the detection level Press the right arrow gt to move the cursor to the right column so you can begin editing 3 Using the up and down arrows change the value of each digit until you obtain the desired detection level from 10 to 99 uV m Press Enter when you are done editing in order to save the new value 4 Repeat steps 2 and 3 for the other band as applicable 5 Press Esc until you return to measurement mode or press the left arrow lt to return to the settings menu and continue configuring other parameters 3 2 10 Setting up the CW to QAM Delta You can configure the relative difference in signal strength between the channel tag s carrier wave CW signal and the QAM signal of the channel band it is inserted into This delta in dB allows the DRV3 to provide leakage readings based on the expected QAM levels and not on the channel tag CW signal emitted by the DSG1 The CW signal may be stronger or weaker than the QAM signal Verify the actual levels before modifying this setting To edit the CW to QAM offsets 1 In the settings menu page 3 select CW QAM cB 2 Press the right arrow to access the band and offset options 3 Sele
27. nit Operation Manual 11 CPAT CONTINUOUS MONITORING SYSTEM and charge the battery while the DRV3 is docked It also has a USB type A receptacle used as a data interface with the ARD4 autonomous monitoring module allowing it to take control of the unit This USB connection is also used for firmware upgrades Figure 4 Docking station and rear view of DRV3 WARNING Do not plug 2 adapters simultaneously to power the DRV3 The docking station is designed to prevent connecting a power adapter to the bottom of the DRV3 when docked The docking station is available with a flexible mounting post that is designed to be installed in a service vehicle For further details and installation procedures see section 3 1 Docking Station Installation starting on page 16 DRV3 effigis com 2 4 5 Antenna Connectors The 2 connectors at the top of the unit are designed for the rubber duck antennas These antennas are used only when the unit is not docked Figure 5 Top view of DRV3 As soon as the DRV3 is docked there is an internal mechanical switch that transfers the RF input readings to the docking station The docking station relays the RF signal from the antennas installed on the vehicle s rooftop The Mid band and the LTE band antennas must be connected to the BNC connector and the SMA connector respectively both located at the back of the docking station Operation Manual 13 CONTINUOUS MONIT DRV3 DRING SYSTEM
28. one cable operator is active and the use of tags allows each operator to identify the leaks that are under its responsibility In order to allow the to recognize channel tags you must configure the DRV3 s channel tag detection parameters so they match the settings used by the headend channel tagger The DRV3 supports the detection of AM tags with modulation frequencies varying from 10 Hz to 110 Hz You can also adjust the detection threshold of the channel tag to allow the DRV3 to discriminate between channel noise and the tag signal Once properly set up you can enable and disable the channel tag detection feature as may be needed when working in different areas When the tag detection feature is enabled and the DRV3 detects the tag in the frequency it is monitoring the letter t appears on the main measurement mode screen To set up and enable disable channel tag detection 1 In the settings menu page 3 select Tag Cfg The current detection setting is displayed to the right 2 Press the right arrow gt to edit the tagging options An asterisk appears next to the choice that is currently enabled ether OFF or AM 3 To change the AM frequency for tag detection highlight AM then press the right arrow gt edit the frequency of the tag s modulation in hertz The possible values are from 10 Hz to 110 Hz Press Enter to save the value 4 If necessary adjust the noise Threshold offset for the channel
29. oth active Reached Yes on signal in ac Enabled and tag detected Only one band active Reached tive band other band ignored Yes on signal in ac Carrier only Only one band active Reached tive band other ban ignored To adjust the reference volume and the squelch level 1 In the settings menu page 2 select Sounds 2 To change the reference level highlight Volume and press the right arrow gt to access the volume options Use the up and down arrows to select the reference level among the available options mute low medium and high Press Enter to save your choice The cursor automatically returns to the left column 3 To change the squelch threshold highlight Squelch and press the right arrow gt to edit the threshold Highlight each digit you want to edit and scroll up and down to change the threshold to a value between 0002 to 9999 uV m 4 Press Enter to save the new value The cursor automatically returns to the left col umn Press Esc to return to the settings menu and continue configuring other parameters Press Ese again to return to measurement mode 3 2 6 Setting up Units The DRV3 can display leakage levels in two different measurement units uV m or dBuV m The most common unit used to measure signal leaks is microvolts per meter and this is DRV3 s default setting Note that the squelch feature will always be calculated in uV m However the DRV3 will apply
30. ou are reading in different locations or at different distances from the leakage source You can take a snapshot by pressing the key labelled which is also the Enter key The captured level will appear in smaller numbers to the right of the current leakage level read ing To take another snapshot press the 4 key again The previous level that was captured is cleared and is replaced with the new snapshot 4 4 Charging the Battery The DRV3 can operate on battery power for hours when fully charged The battery status indicator gives the battery charge level To maintain good battery health and ensure the longest useful battery life you must follow these recommendations for charging the battery 1 Use only the battery pack and replacement battery pack available from Effigis 2 Use only the chargers available through Effigis The DRV3 s status LED will turn green only when the battery is fully charged 3 Charge the unit at room temperature Do not place the unit in a location where tem perature extremes occur during charging The DRV3 is equipped with additional protection to prevent the battery from charging when the temperature is above 40 C 104 F or below 0 C 32 F 4 5 Replacing the Battery Pack The rechargeable Li lon battery pack is accessible via the DRV3 s rear panel You will not need to access the batteries unless they can no longer be recharged To change the battery pack 1 Loosen the battery compar
31. range Plugged in and charging and operating on external power Off or Backlit Operating on battery power lighting depends on backlight settings 2 4 2 Front View Buttons and Display The seven front panel buttons on the DRV3 allow you to turn on and off the unit navigate menus take snapshots and toggle the unit s volume between mute and its preset reference level LCD display Navigation arrow Figure 2 Front view of DRV3 DRV3 effigis com 2 4 3 Power and Data Interface The DRV3 has one round pin interface on the bottom of the unit used only to connect the AC adapter supplied by Effigis when the docking station is not used This connection allows you to recharge the battery and power the DRV3 When the DRV3 is connected to the docking station power and data connections with the unit are made through the 9 pads located on the back of the unit which line up with the docking station s mating connectors Figure 3 Bottom view of DRV3 unit The docking station provides a quick means of connecting and disconnecting the DRV3 without having to unplug any cables The 9 mating connectors align with the pads on the rear of to link power and data to the DRV3 In addition to this basic connection there are two connections for the leakage detection antennas See section 2 4 5 Antenna Connectors on page 13 for further details The docking station is equipped with a round connector at the rear used to power the u
32. re set using the DRV3 menus The following sections describe how to set up the DRV3 using the unit s own menus 3 2 1 Accessing and Navigating the Setup Menus Upon startup the DRV3 defaults to measurement mode In order to change the frequency enable or disable tagging adjust the volume change the units of measure or change any other display setting you must switch to setup mode To go to setup mode press any of the four arrow buttons Once you are in the settings menu you can move through the list of configurable elements by scrolling up and down with the arrows To change the settings of an element press the right arrow gt or the Enter button when the cursor is over the desired element of the menu in the left column This moves the cursor to the right column where you can then select a new value among the presets or edit a numerical value by highlighting the digit and then pressing the up or down arrow to obtain the desired number To save a new setting and return to the left column press the left arrow 4 or the Enter button When editing numerical values press Enter button or Esc to return to the left column n order to save values and exit the settings menu press the left arrow 4 or the Enter button to exit the menu without saving press Esc Please refer to the following sections for details on configuring each element in the five separate pages that constitute the settings menu Operation
33. rmly attach the Flex mount bracket to vehicle floor 3 metal screws not included e 2 Screw the post into bracket 3 Secure the post with the hexagonal screw Hexagonal screw B Attach docking station 1 Attach the DRV3 docking station to the Flex mount using the 4 pan head Phillips screws included with the docking station 2 Adjust docking station orientation and tighten the thumbscrew Pan head Phillips screw Flex mount post DRV3 effigis com C Connect docking station cables 1 SMA cable from vehicle roof antenna LTE band 2 BNC cable from vehicle roof antenna Mid band 3 DC to vehicle accessories 4 USB cable required only if the DRV3 is used with an 5 Secure wires with a cable tie D connect the DRV3 to ARD4 optional Note See CPAT FLEX Operation Manual for the ARD4 installation details J OO USB cable from DRV3 docking station Dock Insert the DRV3 into docking station CLICK Operation Manual 39 effigis GEO SOLUTIONS effigis com 1 888 495 6577
34. ters 3 2 12 Setting up Contrast This parameter controls the screen contrast on the DRV3 s display To adjust the contrast 1 In the settings menu page 4 select Contrast The current setting is displayed to the right 2 Press the right arrow to move to the options and use the up and down arrows to select the contrast value from 0 least contrast to 9 highest contrast Press Enter to save your choice Operation Manual 27 CPAT CONTINUOUS MONITORING SYSTEM 4 Press Ese until you return to measurement mode or press the left arrow 4 to return to the settings menu and continue configuring other parameters 3 2 13 Displaying the DRV3 s Internal Temperature This menu item provides view only access to the DRV3 s temperature To view the unit s internal temperature go to the settings menu page 4 The current tem perature is displayed to the right in Celsius C and in Fahrenheit F Press Esc until you return to measurement mode or press the left arrow 4 to return to the settings menu to configure or view other parameters 3 2 14 Displaying the DRV3 s Version This menu item provides view only access to the DRV3 s internal software versions To view the version numbers go to the settings menu page 5 The unit s micro controller version number is displayed to the right of the letter M and the current version of the firm ware installed in the device is displayed to the ri
35. ting on battery power or shows a plug symbol when the DRV3 is connected to a power source via the docking station or the standalone AC converter The DRV3 s screen in measurement mode shows the following information Operation Manual 29 CPAT CONTINUOUS MONITORING SYSTEM In single band mode Measurement Units Battery Charge icon Last leakage level detected at selected frequency Snapshot icon with level of last snapshot Preguen taken if applicable In dual band mode Measurement Units Battery Charge icon Last LTE band leakage level detected Last Mid Aero band leakage level detected Frequency upon entering measurement Frequency upon entering measurement mode mode Snapshot icon with level of last snapshot taken if Snapshot icon with level of last snapshot taken if applicable applicable Figure 9 Measurement mode screen 4 2 Adjusting Volume During Normal Use The DRV3 emits an audible tone to help you locate the leakage source The tone rises with signal strength from about 200 Hz to about 800 Hz In measurement mode you can enable or mute the audio by pressing the volume key labelled Esc To adjust the reference volume of the audio tone see section 3 2 5 Setting up Sound on page 22 DRV3 30 effigis com 4 3 Using the Snapshot Feature During normal operation you can capture the actual RF level measurement at your leakage monitoring frequency This feature can help you compare levels y
36. tment s screw using a Philips head screwdriver and remove the panel 2 Disconnect the 5 pin mating on the cable between the battery pack and the DRV3 Replace the battery pack only with a battery pack from Effigis 3 Plug in the 5 pin connector and replace the panel on battery compartment Secure the panel with the screw In order to avoid damaging the DRV3 s housing do not overtighten the screw Operation Manual 31 CPAT CONTINUOUS MONITORING SYSTEM Figure 10 Battery compartment 4 6 Updating the DRV3 s Firmware From time to time firmware updates may be available for the DRV3 The update can be automatically pushed by an ARD4 or manually using a computer When a new firmware update is available the Effigis support team will plan update deploy ment with your CPAT internal manager To check which version is currently installed in the DRV3 access the DRV3 s setup mode by pressing the up or down arrow and scroll to the Version menu There are two version numbers each for different components of the DRV3 The second version number after the letter F is the firmware version 4 7 Cleaning Your DRV3 unit can be wiped clean with a damp cloth Do not immerse the unit in water Avoid solvents and commercial cleaners DRV3 82 effigis com Appendix A Specifications A 1 Technical Detector type Dual band digital receiver demodulator Frequency range Agile from 118 to 140 MHz Mid band Agile from 572
37. vice complies with Part 15 of the FCC Rules Operation is subject to the following two conditions e This device may not cause harmful interference e This device must accept any interference received including interference that may Cause undesired operation Operation Manual 5 CPAT CONTINUOUS MONITORING SYSTEM NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment gen erates uses and can radiate radio frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a resi dential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Modifications Any modifications made to this device that are not approved by Effigis may void the authority granted to the user by the FCC to operate this equipment IC ICES 003 Class A Notice Avis NMB 003 Classe A This Class A digital apparatus complies with Canadian ICES 003 1 4 Technical Support Effigis Technical Support Service is available from Monday through Friday from 9 00 AM to 5 00 PM Eastern Time Toll free from U S and Canada
38. y connected to the selected antenna interface The possible values are e Rubber Default value Dipole Monopole e None Used by Effigis service personnel for maintenance calibration purposes DRV3 20 effigis com 4 Press Enter or Left Key to save your choice 5 Press Esc to return to the settings menu and continue configuring other parameters Press Esc again to return to measurement mode NOTE In autonomous mode the DRV3 always uses the roof antennas since it re quires the DRV3 to be docked in order to operate in this mode 3 2 3 Setting up Proximity The proximity setting is used to apply a correction factor to the distance between the DRV3 and the probable leakage source in order to give a reading equivalent to a 10ft 3m measure ment By selecting the distance the DRV3 calculates the appropriate gain to apply to the reading and then provides a normalized reading To change the Proximity 1 In the settings menu page 1 select Proximity 2 Press the right arrow gt to choose the estimated distance to the leakage point The possible values are e 3 meters approx 10 ft Default value e 10 meters approx 30 ft e 25 meters approx 80 ft 3 Depending on your selection the DRV3 will then apply the appropriate gain to the reading to help you discriminate the noise source Use the arrows to make your selection 4 Press Enter to save the value 5 Press Esc to return to measurement mod